Anda di halaman 1dari 5

Data spesifikasi Heat Exchanger 09-A/B/C/D di HVU II Kilang CD & L.

Pertamina
(Persero) RU III Plaju-Sungai Gerong

 Nama alat : Heat Exchanger 09-A/B/C/D


 Jenis alat : Shell and Tube
 Type : Floating Tube Sheet/Horizontal
 Efisiensi data desain : 85%
 Tube side
- Jumlah tube side (Nt) : 728
- Outside diameter tube (OD) : 1 in
- Inside diameter tube (ID) : 0,782 in
- Panjang Tube side (L) : 20 ft
- BWG : 12
- Pitch (Pt) : 1,260 in
- Number of passes tube :8
- Fluida pada tube : Vacuum residu
 Shell side
- Inside diameter shell (ID) : 43,307 in
- Jarak Baffles (B) : 200 mm
- Type : Segmented Vertical
- Number of passes shell :1
- Fluida pada shell : Long Residu

Mengetahui,
Pembimbing Lapangan

Fahrur Rozi
No. Pek. 748872

LEMBAR PENGESAHAN DATA

Data Pengamatan Heat Exchanger 009-A

96
Long Residu (Shell)
Tanggal Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (OC) (OC)

20/07/2016 5700 239 245 0.9064


21/07/2016 5702.5 231 240 0.906
22/07/2016 5750.5 245 251 0.9106
25/07/2016 5702.5 235 248 0.912
26/07/2016 5691 232 241 0.9144

Rata-rata 5709.3 236.4 245.0 0.9099

Vacuum Residu (Tube)


Tanggal Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (°C) (°C)

20/07/2016 1700 285 265 0.9160


21/07/2016 1600 288 266 0.9584
22/07/2016 1700 278 254 0.9575
25/07/2016 1800 283 261 0.9600
26/07/2016 1900 286 265 0.9524
Rata-rata 1740.0 284.0 262.2 0.9489
*data diambildaritanggal 20-26 Juli 2016

Data Pengamatan Heat Exchanger 009-B

Tanggal Long Residu (Shell)

97
Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (OC) (OC)

20/07/2016 5700 229 239 0.9064


21/07/2016 5702.5 224 231 0.906
22/07/2016 5750.5 235 245 0.9106
25/07/2016 5702.5 225 235 0.912
26/07/2016 5691 225 232 0.9144

Rata-rata 5709.3 227.6 236.4 0.9099

Vacuum Residu (Tube)


Tanggal Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (°C) (°C)

20/07/2016 1700 265 242 0.9160


21/07/2016 1600 266 245 0.9584
22/07/2016 1700 254 232 0.9575
25/07/2016 1800 261 237 0.9600
26/07/2016 1900 265 241 0.9524
Rata-rata 1740.0 262.2 239.4 0.9489
*data diambildaritanggal 20-26 Juli 2016

Data Pengamatan Heat Exchanger 009-C

Tanggal Long Residu (Shell)

98
Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (OC) (OC)

20/07/2016 5700 235 245 0.9064


21/07/2016 5702.5 234 240 0.906
22/07/2016 5750.5 242 251 0.9106
25/07/2016 5702.5 239 248 0.912
26/07/2016 5691 229 241 0.9144

Rata-rata 5709.3 235.8 245.0 0.9099

Vacuum Residu (Tube)


Tanggal Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (°C) (°C)

20/07/2016 1700 288 265 0.9160


21/07/2016 1600 274 253 0.9584
22/07/2016 1700 270 248 0.9575
25/07/2016 1800 279 256 0.9600
26/07/2016 1900 272 248 0.9524
Rata-rata 1740.0 276.6 254.0 0.9489
*data diambildaritanggal 20-26 Juli 2016

Data Pengamatan Heat Exchanger 009-D

Tanggal Long Residu (Shell)

99
Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (OC) (OC)

20/07/2016 5700 229 235 0.9064


21/07/2016 5702.5 226 234 0.906
22/07/2016 5750.5 235 242 0.9106
25/07/2016 5702.5 230 239 0.912
26/07/2016 5691 224 229 0.9144

Rata-rata 5709.3 228.8 235.8 0.9099

Vacuum Residu (Tube)


Tanggal Flow Rate Temp. Inlet Temp. Outlet
SpGr
(Ton/Day) (°C) (°C)

20/07/2016 1700 265 244 0.9160


21/07/2016 1600 253 234 0.9584
22/07/2016 1700 248 228 0.9575
25/07/2016 1800 256 236 0.9600
26/07/2016 1900 248 231 0.9524
Rata-rata 1740 254 234.6 0.9489
*data diambildaritanggal 20-26 Juli 2016

Mengetahui,
Pembimbing Lapangan

Fahrur Rozi
No. Pek. 748872

100

Anda mungkin juga menyukai