Anda di halaman 1dari 15

panas gas buang

laju aliran massa gas buang inlet 507.2871 kg/s


Temperatur gas buang inlet superheater 819.8077 K
uap yang dihasilkan HRSG
temperatur 815 K
tekanan 5000 Kpa
laju aliran massa uap 45.7265 kg/s
temperatur di tiap titik komponen
Temp gas inlet superheater
temp gas inlet evaporator
temp gas inlet economizer
temp gas inlet preheater
temp gas outlet preheater
HRSG ECONOMIZER
flow gas buang 507.2871 kg/s flow
pressure gas buang 101.32 Kpa pressure
Temperature gas buang inlet 819.8077 K temp inlet
gas buang gas buang
temperature gas buang outlet 559.5586 K temp outlet
entalpi gas buang inlet 584.8554 Kj/Kg entalpi inlet
entalpi gas buang outlet 289.8485 Kj/Kg entalpi outlet
flow feedwater inlet 45.7265 Kg/s flow
Pressure feedwater inlet 5000 KPa pressure
feedwater
Temperature feedwater inlet 333.6652 K temp inlet
water
entalpi feedwater inlet 257.4135 Kj/Kg temp outlet
flow 45.7265 kg/s entalpi inlet
Pressure 5000 KPa entalpi outlet
steam
Temperature 815 K
entalpi 3530.204 Kj/Kg parameter
Tin
Pin
m in
h in
Tout
Pout
h out
ECONOMIZER
507.2871 Kg/s
101.32 Kpa
462.1057 K
448.508 K
183.9496 Kj/kg
169.3416 Kj/kg
24.3346 Kg/s
1200 Kpa
338.5485 K
410 K
274.6655 Kj/kg
576.1733 Kj/kg

Parameter water Flue gas satuan


temp inlet 338.5485 462.1057 K
pressure 1200 101.32 Kpa
flow 24.3346 507.2871 Kg/s
entalpi inlet 274.6655 183.9496 Kj/kg
temp outlet 410 448.508 K
pressure 1200 101.32 Kpa
entalpi outlet 576.1733 169.3416 Kj/kg
Gas Inlet Gas Outlet Water Inlet Water Outlet
Flows kg/sec 507.2871 507.2871 24.3346 24.3346
Pressure kPa 101.32 101.32 1200 1200
Temperature K 462.1057 448.508 338.5485 410
Enthalpy kJ/kg 183.9496 169.3416 274.6655 576.1733
ECONOMIZER parameter Parameter water
flow 507.2871 Kg/s Tin temp inlet 338.5485
pressure 101.32 Kpa Pin pressure 1200
temp inlet 462.1057 K m in flow 24.3346
gas buang
temp outlet 448.508 K h in entalpi inlet 274.6655
entalpi inlet 183.9496 Kj/kg Tout temp outlet 410
entalpi outlet 169.3416 Kj/kg Pout pressure 1200
flow 24.3346 Kg/s h out entalpi outlet 576.1733
pressure 1200 Kpa
temp inlet 338.5485 K
water
temp outlet 410 K
entalpi inlet 274.6655 Kj/kg
entalpi outlet 576.1733 Kj/kg

Perhitungan Heat Balance


1 Q laju aliran mass uap
kJ/s 7337.07170988
2 LMTD
Tgi-Tao 52.1057
Tgo-Tai 109.9595
LMTD 77.4650164291
3 faktor koreksi perpindahan kalor susunan pipa ekonomizer
P 0.1100518626
R 5.254675423
F dari grafik lampiran 1
Perancangan pipa ekonomizer
Koefisien perpindahan kalor konveksi
1 Tr air temperatur rata-rata air
C
2 sifat air pada temp rata-rata
3 kecepatan rata-rata
4 bilangan reynold
5 bilangan prandl
6 bilangan nusselt
7 koefisien perpindahan kalor konveksi
Perhitungan temperatur dinding ekonomizer
Flue gas satuan water Flue gas satuan
462.1057 K 65.3985 188.9557 C
101.32 Kpa 1.2 0.10132 Mpa
507.2871 Kg/s 24.3346 507.2871 Kg/s
183.9496 Kj/kg 274.6655 183.9496 Kj/kg
448.508 K 136.85 175.358 C
101.32 Kpa 1.2 0.10132 Mpa
169.3416 Kj/kg 576.1733 169.3416 Kj/kg
ECONOMIZER
flow �  ̇_� 601.3 Kg/s
𝑎𝑡𝑒�
pressure 101.32 Kpa
temp inlet �_�� 600.68 K
gas buang �_��
temp outlet 584.7 K
entalpi inlet ℎ_�� 427.63 Kj/kg
entalpi outlet ℎ_�� 314.332 Kj/kg
flow �  ̇_� 24.11 Kg/s
𝑎�
pressure 5000 Kpa
temp inlet �_�� 368.6 K
water
temp outlet �_�� 470 K
entalpi inlet ℎ_�� 398 Kj/kg
entalpi outlet ℎ_�� 841.02 Kj/kg

Perhitungan Heat Balance


1 Q laju aliran mass uap �_��
kJ/s 10681.21 �_��
2 LMTD �_��
Tgi-Tao 130.68 �_��
Tgo-Tai 216.1 �  ̇_�
𝑎𝑡𝑒�
�  ̇ _�
LMTD 169.82 169.82
𝑎�
ℎ_��
3 faktor koreksi perpindahan kalor susunan pipa ekonomizer
P 0.07 ℎ_��
R 6.35 ℎ_��
F 1 dari grafik lampiran 1 ℎ_��
Perancangan pipa ekonomizer
Koefisien perpindahan kalor konveksi
1 Tr air temperatur rata-rata air
C
2 sifat air pada temp rata-rata
3 kecepatan rata-rata
4 bilangan reynold
5 bilangan prandl
6 bilangan nusselt
7 koefisien perpindahan kalor konveksi
Perhitungan temperatur dinding ekonomizer
parameterParameter water Flue gas satuan water Flue gas satuan
Tin temp inlet 368.6 600.68 K 65.3985 188.9557 C
Pin pressure 5000 101.32 Kpa 1.2 0.10132 Mpa 725.1887
m in flow 24.11 601.3 Kg/s 24.3346 507.2871 Kg/s
h in entalpi inle 398 427.63 Kj/kg 274.6655 183.9496 Kj/kg
Tout temp outle 470 584.7 K 136.85 175.358 C
Pout pressure 5000 101.32 Kpa 1.2 0.10132 Mpa
h out entalpi out 841.02 314.332 Kj/kg 576.1733 169.3416 Kj/kg
14.69522 psi
ECONOMIZER
SI formal SI customary
flow �  ̇_� 601.3 Kg/s 601.3
𝑎�
�_�
pressure 101.32 Kpa 1.0132
temp inlet �_�� 600.68 K 327.53
gas buang �_��
temp outlet 584.7 K 311.55
entalpi inlet ℎ_�� 427.63 Kj/kg 427.63
entalpi outlet ℎ_�� 314.332 Kj/kg 314.332
flow �  ̇_� 24.11 Kg/s 24.11
𝑎𝑡𝑒�
�_�
pressure 5000 Kpa 0.05
temp inlet �_�� 368.6 K 95.45
water
temp outlet �_�� 470 K 196.85
entalpi inlet ℎ_�� 398 Kj/kg 398
entalpi outlet ℎ_�� 841.02 Kj/kg 841.02

Perhitungan Heat Balance satuan


1 laju aliran massa uap (Q) �_��
Q= 10681.21 kJ/s �_��
2 LMTD �_��
Tgi-Tao 130.68 �_��
Tgo-Tai 216.1 �  ̇_�
𝑎𝑡𝑒�
�  ̇ _�
LMTD= 169.82 K
𝑎�
ℎ_��
3 faktor koreksi perpindahan kalor susunan pipa ekonomizer
P 0.07 ℎ_��
R 6.35 ℎ_��
F 1 dari grafik lampiran 1 ℎ_��
Perancangan pipa ekonomizer
asumsi pipa berbahan baja schedule 40
diameter dalam (di) 2.067 inch 0.0525 m
diameter luar (do) 2.375 inch 0.0603 m
tebal pipa (t) 0.154 inch 0.0039 m
fin
tebal sirip (w) 0.001 m
tinggi sirip (h) 0.015 m
jarak antar sirip (s) 0.00557 m
jumlah sirip (nf) 158 m
panjang rangkaian pipa (Lb) 7m
panjang pipa per batang (L) 14.64 m
jarak antar pipa vertikal (p1) 0.1206 m
jarak antar pipa horizontal (p2) 0.0945 m
jarak antar pipa horizontal (p2) 0.11 m
1 jumlah pipa (N)
59.0431177446 pipa per baris
60 pipa per baris
2 material pipa
Sa= 4346.42568247 psia
Koefisien perpindahan kalor konveksi di dalam pipa ekonomiser
1 temperatur rata-rata air (Tr air)
Tr air 419.3 °K
146.15 C
2 sifat air pada temp rata-rata
berdasarkan Tr dan P P 5000 kPa
50 bar
parameter nilai satuan
volume jenis (ν) #NAME? m3/kg
Density atau Rho (ρ) #NAME? Kg/m3
Kalor spesifik (Cp) #NAME? kJ/kg°C
Viskositas Dinamik (μ) #NAME? Pa.s Centipoise #NAME? satuan??
Konduktivitas termal (k) #NAME? W/m°K W/mC #NAME?
http://www.peacesoftware.de/einigewerte/calc_dampf.php5
3 kecepatan rata-rata
A1 0.0021636563 m2
#NAME? m/s ini liat standar kecepatan economizer, memenuhi stan
4 bilangan reynold #NAME? ref k.acep
5 bilangan prandl #NAME?
6 bilangan nusselt #NAME?
7 koefisien perpindahan kalor konveksi
hi #NAME? liat yg k.acep..satuan k pengaruh
Perhitungan temperatur dinding ekonomizer
1 temp permukaan bag dalam
Tsi °C
2 temp permukaan bag luar
Tso °C
Koefisien perpindahan kalor konveksi di luar pipa ekonomiser
1 temperatur rata-rata gas buang (Tr gas buang)
Tr air 592.69 °K
319.54 C
2 sifat air pada temp rata-rata
berdasarkan P 101.32 kPa
1.0132 bar
parameter nilai satuan
volume jenis (ν) #NAME? m3/kg
Rho (ρ) #NAME? Kg/m3
Kalor spesifik (Cp) #NAME? J/Kg°K
Viskositas Dinamik (μ) #NAME? Pa.s
Konduktivitas termal (k) #NAME? W/m°K
http://www.peacesoftware.de/einigewerte/calc_dampf.php5
3 kecepatan maksimum gas buang
luas penampang min (Apmin) 0 m2
m/s
4 bilangan reynold
5 bilangan prandl
6 bilangan nusselt
7 koefisien perpindahan kalor konveksi
Koefisien perpindahan panas keseluruhan (U)
laju perpindahan kalor keseluruhan
SI customary
Kg/s
Bar 14.69522 psi
°C parameter
°C Tin
Kj/kg Pin
Kj/kg m in
Kg/s h in
Bar 725.1887 psi Tout
°C Pout
°C h out
Kj/kg
Kj/kg

�_��
�_��
�_��
�_��
�  ̇_�
𝑎𝑡𝑒�
�  ̇ _�
𝑎�
ℎ_��
ℎ_��
ℎ_��
ℎ_��
an economizer, memenuhi standar atau ngga
Parameter water Flue gas satuan water Flue gas satuan
temp inlet 368.6 600.68 K 65.3985 188.9557 C
pressure 5000 101.32 Kpa 1.2 0.10132 Mpa
flow 24.11 601.3 Kg/s 24.3346 507.2871 Kg/s
entalpi inle 398 427.63 Kj/kg 274.6655 183.9496 Kj/kg
temp outle 470 584.7 K 136.85 175.358 C
pressure 5000 101.32 Kpa 1.2 0.10132 Mpa
entalpi out 841.02 314.332 Kj/kg 576.1733 169.3416 Kj/kg

Anda mungkin juga menyukai