Anda di halaman 1dari 1

Sample : Zinc Dross

Operator:
Comment : Sampel Ibu Eka Untirta
Group : easy
Date : 2018-08-31 16:22:44

Measurement Condition
------------------------------------------------------------------------------------
Instrument: EDX-7000 Atmosphere: Air Collimator: 10(mm)
------------------------------------------------------------------------------------
Analyte TG kV uA FI Acq.(keV) Anal.(keV) Time(sec) DT(%)
------------------------------------------------------------------------------------
Al-U Rh 50 7-Auto ---- 0 - 40 0.00-40.00 Live- 30 40
Na-Sc Rh 15 74-Auto ---- 0 - 20 0.00- 4.40 Live- 30 30

Quantitative Result
------------------------------------------------------------------------------------
Analyte Result [3-sigma] Proc.-Calc. Line Int.(cps/uA)
------------------------------------------------------------------------------------
Zn 90.689 % [ 0.188] Quan-FP ZnKa 10227.1050
Fe 6.629 % [ 0.044] Quan-FP FeKa 987.4327
Si 1.148 % [ 0.139] Quan-FP SiKa 0.1993
Mn 0.559 % [ 0.014] Quan-FP MnKa 61.8552
Pb 0.375 % [ 0.021] Quan-FP PbLb1 8.7742
Ca 0.219 % [ 0.018] Quan-FP CaKa 1.1821
S 0.165 % [ 0.036] Quan-FP S Ka 0.2487
Ni 0.121 % [ 0.004] Quan-FP NiKa 22.5167
Cu 0.095 % [ 0.010] Quan-FP CuKa 12.0011

Anda mungkin juga menyukai