INDICATORS
LV...
The level indicators series is available for both static and These indicators are available in three configurations, with
mobile applications; the construction materials used make it transparent plastic body, with black body, and/or an aluminum
possible to operate with wide temperature variations and body. Fixing to reservoirs with unthreaded holes or reduced
compatibility with all hydraulic fluids. thickness can be achieved using series LCC/T
Series LV... level indicators are available with fixing center equipped with expansion kit.
distance from 3.0” to 39.3”. Temperature
LVK • LVA: from -13°F to +212°F
This level indicator series is available with electric alarm and • LVU: from -13°F to +158°F
visual and electrical temperature switches, level indicators are • LVU: from -13°F to +212°F (only with pyrex lens)
available with fixing center distance from 3.0” to 10”. • LVK/LC...: from -4°F to +176°F
Compatibility
LC...
LVA/LVK/LVU
LC... series sight plugs allow visibility of the fluid contained in • NBR seals and Cork Gasket, compatible with:
the reservoirs, showing the level and also any changes in Mineral oils to ISO 2943 - aqueous emulsions
transparency and emulsion. Synthetic fluids, glycol water.
• FPM seals, compatible with:
Synthetic fluids type HS-HFDR-HFDS-HFDU.
LC...
• Mineral oils to ISO 2943 - aqueous emulsions
46 Synthetic fluids, glycol water.
2 1 3a
Series LVA
6
3c
Dimensions
3b
0.75”
5
B
4
A
H
A
LVA (Materials)
0.75”
ØC
1 - Cover: Polyamide A/F
2 - Screws: Phosphated steel 1.5” 6 (mm) 0.93” 0.77”
3 - Seals: NBR or
FPM
Weight
4 - Lens: Polyamide Size A H (lbs)
5 - Nameplate: Painted aluminum
LVA10 3” 4.5” 0.29
6 - Terminal cap: Nylon LVA20 5” 6.5” 0.40
7 - Nuts: Galvanized steel LVA30 10” 11.5” 0.51
Type B C
Quantity per pack
Number of Parts
LVA......M10 M10 0.41”
LVA 10 LVA......M12 M12 0.49”
LVA......U38 3/8” UNC 0.41”
LVA......U12 1/2” UNC 0.53”
Screw tightening torque: 11 ft-lbs
Ordering information
LVA20T.....S01
1 2 3 4 5 6
LVA
Example: LVA 20 T A P M10 S01
1 - Size 4 - Cover
10 P Cover polyammide
20 5 - Connection
3 - Seals 6 - Options
A NBR S01 With nuts - Tag MP Filtri
MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved. 47
Series LVK
Description
Visual/electric level indicator with temperature
controls for both static and mobile applications. 3
Completely transparent, it provides a view of the fluid
1
over the entire length, both from the front and on both
sides. 2
The quality and thickness, 0,16”, of the
4
construction material provides the utmost
3
dependability and mechanical strength without any
need for additional protection.
LVK (Materials)
1 - Body: Polyammide
2 - Screws: Nickel plated brass (Standard)
AISI 316 (Option)
3 - Seals: NBR (Standard) 5 2
Dimensions
Reservoir Sensor thermometer
holes
0.63”
Ø 2.05”
A/F - 6 mm
A/F - 12 mm
A/F - 22 mm
H
M12
A
0.91” 2.44”
B
0.63”
Weight
ØC (lbs)
1.1” 0.63” 1.26” TV12 0.22 Kit Sensor thermometer
+ Screw M12
1.42”
Weight 2.68”
Size A H (lbs)
Type B C
LVK10 3” 4.25” 0.31
LVK20 5” 6.26” 0.37 LVK......M10 M10 0.41”
48 LVK30 10” 11.26” 0.55 LVK......M12 M12 0.49”
Combination of available electrical contacts
T T T T
Thermostat
Thermostat
1 2 1 2 1 2 1 2
3 3 3
Level Level
T T
PT 100
1
PT 100
1 2 2
B
3 3
1.10” 0.87”
Level Level
49
Ordering information
1 2 3 4 5 6 7
LVK
Example: LVK 20 A M12 1 S S P01
1 - Size 5 - Style
10 S Standard
2 - Seal 6 - Thermostat
1 122°F N.O.
3 - Connection
2 140°F N.O.
M10 Screws M10
3 158°F N.O. Only for
M12 Screws M12 (Standard)
5 122°F N.C. style “T”
4 - Electrical contacts with no liquid*
1 N.O. 6 140°F N.C.
P01 MP Standard
* Available electrical contacts see page 49
MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved.
Accessories/Options*
50