Anda di halaman 1dari 2

BAC-6000 Series Round Thermostat FEATURES BEFORE WIRING AND INSTALLING...

User Guide On Appearance

2. 51mm round display area helps to protect your eyes.


3. Installer must be a trained, experienced service technician.
5. Amazing Silver Frame opens your modern life.
6. The visiable thickenss above the wall is only 11mm.

8. 86mm hidden box and european 60mm round box is suitable. CAUTION
9. White, black or gold housing creates your colorful life.
Electrical Shock or Equipment Damage Hazard. Can shock
individuals or short equipment circuitry.

2. 0.5°C Accuracy keeps temperature within the level you set.


3. ℃ & ℉ WIRING
4. Data memory when power is off.
L AC95-240V 50~60Hz
For Fan Coil Unit AC95-240V 50~60Hz N AC95-240V 50~60Hz
DIMENSION 86mm Valve
Cooling
Valve
N L N L

60mm Valve Fan 0-10V


50mm M Fan Modbus Valve Fan
M M
B A - +

Welcome

Low
Med
High
C lose
Open
Thank you for your purchase.

Open
Close
Open
Open
Close
Close

Med
High
Med
High
86mm

Low
Low
Your new thermostat will provide uniform and comfortable
temperature control throughout every room in your property. We
bring together technology, A (RED) Modbus
B (WHITE) A (RED) Modbus A (RED) Modbus
materials to provide you with a safe, reliable product combined with 50mm
B (WHITE) B (WHITE)

sleek, contemporary design. 14mm

programming manual for comprehensive Two Pipe, On/off Four Pipe , On/off Two Pipe
thermostat. Please also
ensure a suitably qualified person installs your thermostat and 90mm
INSTALLATION
Back

90mm

50mm
In the box you will find Front Step 1. Keep power off. See Fig 1.
Thermostat 1pc Screws 2pc Side Unit: mm
User Guide 1pc Wall plate 1pc 30mm
1pc Fig 1 Fig 2
QC Passed
TECHNICAL DATA
ABOUT YOUR THERMOSTATS
Power Supply: 95 ~ 240 VAC, 50 ~ 60HZ
BAC-6000 series Modern Round Touch Screen Room Thermostats

Sensor: NTC3950, 10K


temp. as reaching the aim of comfort and saving energy. Accuracy: ±0.5℃
Set Temp. Range: 5 -35 ℃ Step 3. Connect power supply, load into the appropriate terminals.
MODEL DEFINITION Dispaly Temp. Range: 5 ~ 99℃ (see “Wiring your thermostat” for details and Fig 3).
A : Two pipe; Control Fan Coil Unit and Two Wired Motorized Valve Ambient Temp.: 0 ~ 45 ℃
M : Two pipe; Control Fan Coil Unit and 0-10V Motorized Valve Ambient Humidity: 5 ~ 95 % RH (Non Condensing)
the box. See Fig 4.
E : Four pipe; Control Fan Coil Unit and Two Wired Heat Valve and Storage Temp.: -5 ~ 45 ℃
Two Wired Cool Valve. Fig 3 Fig 4
N Timing Error: < 1%
Shell Material: PC +ABS ( Fireproof)
K : Keycard T : Clock
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2
W2 : Window P : Programmable
E : External Sensor
For example: BAC-6000EN
During Power Off SIMPLE EXCEPTION HANDLING
No. Phenomenons Handling
When power is off, press and hold M 1 Power is on but without display. * Check if the terminals between LCD panel and
Fig 5 Fig 6 Power Unit Box is loosen.
Then press M to change the different items. 2 Without output but display works. * Use a new LCD panel or new Power Unit Box to
replace the old one.
3 Room Temp. Is a little different from * Do temperature calibration in item 1 of high
No Function Setting & Options Default the actual. senior options

Temp. -9℃ to 9℃
1 -2 SERVICE
Calibration
00:When room temp. reaches the
Your thermostat carries an 18 month warranty from date
of purchase. Service outwith the warranty period may
HOME SCREEN QUICK REFERENCE ① Monday To Sunday (Not For Modbus) setpoint, the fan will turn off.
② Valve On 2 Fan Control
01:When room temp. reaches the
00 incur a charge. More detail please contact with us directly.
③Room Temp.
⑳ ⑲⑱ ④Set Temp. setpoint, the fan will turn to low speed.
⑤Wifi (Not For Modbus)

00 :All the buttons are locked except
⑦Energysaving (Keycard Out)(Not For Modbus) 3 Lock POWER 01
⑧Clock (Not For Modbus)
01:All the buttons are locked
⑨Manual
⑩Cooling Mode 4 Heat/Cool 00:Cool only 01:Heat/Cool 01



⑰ 5 Min. Set Temp. 5-15℃ 10
⑫Time Display(Not For Modbus)
Timing On/Off(Not For Modbus) 6 Max. Set Temp. 5-35℃ 30
③ ⑯⑬
④ ⑭Sleeping Mode 7 Time Display 00:12 hours 01:24 hours 01

⑮Humidity(Not For Modbus)
⑤ 00:Display set temp. only
⑥ ⑯℃ or ℉(Not For Modbus)
⑦ ⑭ ⑰Period 1 to Period 6(Not For Modbus)

8 Display Mode 01 : Display both set temp. and room 01


⑱Room Temp. Display

temp.
⑳Low/Med/High/Auto 9
Fan Speed
21 Standby Brightness of 01-255; bigger value, more brightness
A 10
22 Backlight
23 Fan Speed Adjustment
24 Mode B
⑩ ⑪ ⑫
25 Power On/Off C Deadzone Temp. 1 ~ 5℃. 1
D IP Setting 0 x 01-0 x FF 1
OPERATION E Baud Rate Setting
1:9600, 2:14400, 3: 19200, 4:38400,
1
During Power On 5: 56000, 6: 57600, 7: 115200

1. Power On/off: Press to turn the thermostat on/off.

In the mode of manual, press to set temperature. will

3. Locking your thermostat


Press and hold the and arrows for 5 seconds to lock/unlock
your thermostat.
4
Press M to change the system mode HEATING, COOLING and
VENTILATION. In the mode of VENTILATION, the valve is off but the
fan runs.
5
Press to select the fan speed AUTO, HIGH, MED, LOW.