Anda di halaman 1dari 2

Protection and Control IED Manager 1MRS756450

PCM600 Issued: 11.12.2007


Version: R/10.1.2018

INSTALLATION GUIDE
Related items
PCM600 Ver. 2.9 Installation DVD

PCM600 Ver. 2.9 Setup can be downloaded from https://www143.abb.com/SoftwareLibrary

Content on DVD
 PCM600 Setup
 PCM600 Ver. 2.8 Readme file
 PCM600 Ver. 2.8 Installation Guide
 PCM600 Ver. 2.8 Product Guide

PCM600 Setup includes the following software:


 Protection and Control IED Manager PCM600 Ver. 2.9
 Generic IEC 61850 IED Connectivity Package Ver. 2.5
 Wavewin Tool for Disturbance Analysis
 PCM600 Update Manager

System requirements PCM600 requires Microsoft SQL Server 2014


Express edition. The correct SQL Server instance
Operating system: Windows 7, Windows 8/8.1,
will be installed automatically. If the correct SQL
Windows 10 (see note about Windows 10),
Server instance is already installed, PCM600
Windows Server 2008 R2, Windows Server 2012
installation will skip this step. The SQL Server
R2, Windows Server 2016
requires .NET 4.0 or higher that will also be installed
when required. The .NET Framework might require
Windows must be up-to-date in order to support the
a reboot.
required runtimes and software components
required by PCM600. It is recommended to run
Installation requires administrator rights. In all
Windows update before installing PCM600.
versions of Windows it might be necessary to switch
Hardware requirements, off or configure antivirus software to not block the
minimum/recommended: installation and operation of PCM600 (e.g. McAfee
Host Intrusion Prevention).
Physical RAM memory: 2 GB / 4 GB
Free hard disk space: 4 GB / 8 GB Windows 10
Processor: 1.5 GHz / 2.4 GHz
When upgrading operating system from an earlier
Windows compatible pointer (e.g. mouse) Windows version to Windows 10 with PCM600
already installed, an additional reboot might be
How to install PCM600 Ver. 2.9 required to start all needed services.

a) DVD Installation: Prerequisites for using PCM600 Ver. 2.9


Insert the installation DVD into the DVD-drive. If the
setup doesn’t start automatically, execute To operate with PCM600, there must be at least one
setup.exe in the root folder of the installation DVD. IED Connectivity Package installed and selected to
be used with PCM600 Ver. 2.9.
b) Downloaded from ABB Software Library:
After free registration, you will get an email with a License
link to download the executable installation. Start There is no license required for PCM600 Ver. 2.9.
the installation and follow the instructions.
IEC 61850 communication configuration
After the installation starts, select the needed soft-
ware components and follow the instructions to Separate IEC 61850 communication configuration
complete the installation. software can be purchased through ABB sales
representatives.

1
Protection and Control IED Manager 1MRS756450
PCM600 Issued: 11.12.2007
Version: R/10.1.2018

Previous versions of PCM600 SQL Server 2016 and later versions


PCM600 2.9 can be installed in parallel with a PCM600 is not compatible with SQL Server 2016 or
previous version. If you only want to use PCM600 later versions of the SQL Server. PCM600 SQL
2.9, you should uninstall the previous version of Server 2014 instance should not be upgraded to
PCM600 before installing PCM600 2.9. It is SQL Server 2016 or later.
recommended to install PCM600 versions in
ascending order. E.g. PCM600 2.5 cannot be
installed on top of PCM600 2.8.
Disclaimer
If PCM600 2.5 or an older version is uninstalled The information in this document is subject to change without
after PCM600 2.9 has been installed, PCM600 2.9 notice and should not be construed as a commitment by ABB
Oy. ABB Oy assumes no responsibility for any errors that may
will be broken and must be repaired. This can be appear in this document.
done through Control Panel and Uninstall a
Program. © Copyright 2018 ABB Oy

All rights reserved.


When opening projects in PCM600 2.9 that have
been created with previous versions of PCM600, Trademarks
the projects will be converted automatically. After ABB is a registered trademark of ABB Group. All other brand or
project conversion, the projects can't be opened product names mentioned in this document may be trademarks
with older PCM600 versions anymore. or registered trademarks of their respective holders.

In order to migrate IED 670 configuration from


PCM600 Ver. 1.5 to 2.9 (the whole PCM600 project
including all IEDs in the project), please refer to the
document “1MRG002586 - Configuration Migration
for 670 series in PCM600 User Manual", that can
be found on the 670 series ConnPack DVD.

SQL Server access rights


In PCM600 2.8 and later versions, data security has
been enhanced, and for that reason every Windows
user using PCM600 must be given privileges to
PCM600 project data. These privileges are given by
adding the Windows user to new
“PCMSERVER2014 Users” user group.

During installation, the user logged in is


automatically added to “PCMSERVER2014
Users” group. If additional users are required, they
have to be added to the user group manually. This
can be done by using lusrmgr.msc (“Local Users
and Groups (Local)”). This function provides a
possibility to add both local and network user
accounts to PCMSERVER2014 Users Group.

SQL Server 2014 Express


PCM600 2.8 and later versions are using Microsoft
SQL Server 2014 Express. This instance is
separate from and doesn’t interfere with the SQL
instance in PCM600 2.7 and older versions that use
SQL Server 2008 Express. The two instances can
co-exist.