Anda di halaman 1dari 188

Photoelectric Sensors

XU Photoelectric Sensors

File 9006

CONTENTS
Description Page
Selection and Application Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
XUB 18 mm Cylindrical Metal and Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
XUM Miniature Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
XUK SubCompact 50 x 50 Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
XUX Compact Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
XUD Fiber Optic Amplifier Self Teach. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Schneider Electric Brands Classic / Application Specific and Other. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Operation and Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Photoelectric Sensors
Selection Guide
Selection Guide
Photoelectric Sensors

XUA Miniature XU 18mm XU 18mm XUB 18mm XUB 18mm XUML


Precision Classic Economy Classic Multi-Mode Classic Economy
Tubular Ultra Short Tubular Tubular Tubular Tubular Miniature
Style
8 mm dia 18 mm Diameter 18 mm Diameter 18 mm Diameter 18 mm Diameter Rectangular
Material Metal Metal and Plastic Metal and Plastic Metal and Plastic Metal and Plastic Plastic
Housing NEMA Type 4, 6, 6P, 12, 13 4X (indoor), 12 4X (indoor), 12 4X (indoor), 12 4X (indoor), 12 1, 3, 4, 6, 6P, 12, 13
CENELEC Type IP67 IP67 IP67 IP67 IP67 IP67
Thru-beam 6.6 ft (2 m) 41 ft (12.5 m) 65.6 ft (20 m) 48 ft (15 m) 48 ft (15 m) 43 ft (13 m)
Retroreflective
Maximum – 11.5 ft (3.5 m) 13 ft. (4 m) 6.6 ft (2 m) 6.6 ft (2 m) 13 ft (4 m)
Polarized
Sensing
Range Non-polarized – 18 ft (5.5 m) 19.7 ft (6 m) – 13 ft (4 m) 19 ft (6 m)
Proximity Diffuse 23.6 "(60 cm) / 12" (30 cm) / 23.6" (60 cm) / 2.3 ft (0.7 m) /
1.9 in (5 cm) 5.9 in (15 cm) / -
(Standard/Short Range) 5.9" (15 cm) 4.8" (12 cm) 4" (10 cm) 10 in (.25 m)
Glass Fiber Optics Option No No No No No No
Output DC DC AC, DC DC, AC/DC DC DC
Page 60 62 70 30 38 96

XUJ XUX XUX XUE XUFA XUFS


Universal Multi-Mode
Standard Compact Compact Long Range Glass Fiber Optic
Style Glass Fiber Optic Cables
Rectangular Rectangular Rectangular Rectangular Cables
Material Plastic Plastic Plastic Plastic Glass Glass
Housing NEMA Type 1, 3, 6, 12, 13 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13 1, 3, 4, 13 – –
CENELEC Type IP67 IP67 IP67 IP67 – –
Thru-beam 42.6 ft (13 m) 130 ft (40 m) 130 ft (40 m) 203 ft (62 m) 28 in (70 cm) 9.84 in (250 mm)
Retroreflective
Maximum 29.5 ft (9 m) 36 ft (11 m) 36 ft (11 m) 33 ft (10 m) – –
Polarized
Sensing
Range Non-polarized 29.5 ft (9 m) 45 ft (14 m) – 41 ft (12.5 m) – –
Proximity Diffuse 48 in (1.2 m) / 6.6 ft (2 m) /
7.9 ft (2.1 m) 6.6 ft (2 m) 5.9 in (15 cm) 3.44 in (87 mm)
(Standard/short range) 27 in (70 cm) 4.2 ft (1.3 m)
Glass Fiber Optics Option No No No Yes – –
Output AC/DC, DC DC DC, AC/DC AC/DC, DC – –
Page 108 56 54 112 116 120

10
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide
Selection Guide

Photoelectric Sensors
XUM Classic XUMA XUM XUK XUK XUK XUC XUL XUJL
High-Performance Multi-Mode Multi-Mode Classic Economy
Miniature Miniature Miniature SubCompact SubCompact Compact SubCompact Standard
SubCompact
Rectangular Rectangular Rectangular Universal Universal Universal Rectangular Rectangular
Plastic Plastic Plastic Plastic Plastic Plastic Plastic Plastic Plastic
1, 3, 4, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13 1, 3, 6, 12, 13
IP67 IP67 IP67 IP65 IP65 IP65 IP67 IP67 IP67
33 ft (10 m) 45.9 ft (14 m) 26 ft ( 8 m) 98 ft (30 m) 98.4 ft (30 m) 98.4 ft (30 m) 196 ft (60 m) 33 ft (10 m) 65.6 ft (20 m)
8 ft (2.5 m) 9.8 ft (3 m) 6.6 ft (2 m) 16 ft (5 m) 13 ft (4 m) 19.7 ft (6 m) 29.5 ft (9 m) 16 ft (5 m) 24 ft (7.3 m)
13 ft (4 m) — 13 ft (4 m) 30 ft (9 m) 2.6 ft (0.8 m) 32.8 ft (10 m) — 25 ft (8 m) 33 ft (10 m)
3 ft (0.9 m) / 5 in (0.13 m)
15.7" (40 cm) /
Convergent Beam 0.6 in 15.7" (40 cm) 3.3 ft (1m) 11.8" (300 mm) 4.9 ft (1.5 m) 3.9 ft (1.2 m) adj 2.3 ft (.7 m) —
3.9" (10 cm)
(15 mm)
No No No No No — — No No
DC DC DC DC DC, AC/DC AC/DC, DC AC/DC, DC AC/DC, DC AC/DC
98 46 48 52 50 100 102 104 106

-
+
XUE XUFN XUD XUD Plus XUDA1 XUDA2
Classic Classic Self-Teach Self-Teach
Amplifier for Fiber Optic Universal Amplifier
Plastic Fiber Optic Cables Fiber Optic Amplifier Fiber Optic Amplifier
XUFA Fiber Optics Amplifier for Fiber Optics
Plastic Plastic Plastic Plastic Plastic Plastic
– – 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13
IP40 – IP66 IP66 IP66 IP66
see Fiber Optics 9.84 in (250 mm) see Fiber Optics see Fiber Optics see Fiber Optics see Fiber Optics

– – – – – –

– – – – – –
see Fiber Optics 3.44 in (87 mm) see Fiber Optics see Fiber Optics see Fiber Optics see Fiber Optics
Yes – – – – –
AC/DC – – – DC DC
118 120 124 124 58 58

11
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Selection Guide
Selection Guide
Photoelectric Sensors

XUFN XUVK XU XUB XUKT


Optical Sensing Heads and
Style Application specific Tubular 18 mm dia. Transparent Material Detection Transparent Material Detection
Amplifiers
Material Plastic Plastic Stainless Steel Plastic Plastic
NEMA Type — — 4X, 12 — 3, 4, 4X, 6, 12, 13
Housing
Amps IP50; Heads IP50, 66,
CENELEC Type — IP67 IP67 IP67
67
Thru-beam 59 in (1500 mm) 24 ft (7.3 m) 48 ft (15 m) — —
Retroreflective
— — 6.6 ft (2 m) — 4.9 ft. (1.5 m)
Maximum Polarized
Sensing Non-polarized — 8 ft (2.5 m) 13 ft (4 m) 31.5 in (80 cm) —
Range
Proximity Diffuse
(Standard/Short 3.74 in (95 mm) 5 in (125 mm) 4" (100 mm) — —
Range)
Glass Fiber Optics Option — — No No —
Output — AC, DC DC DC DC
Page 122 126, 128 80 92 132

XU 18 XURU XURC3 XURC4 XUFN


Fiber Optic Full Color Convergent Beam
Style Ultra Violet Ultra Violet Self Teach Full Color Detector
Detector Fiber Optic Cables
Material Nickel Plated Brass Die cast zinc Aluminum Aluminum Plastic
Housing
CENELEC Type IP67 IP67 IP67 IP67 —
Thru-beam — — — — 1.18 in Convergent (30 mm)
Retroreflective
Maximum — — — — —
Polarized
Sensing
Range Non-polarized — — — see Fiber Optics —
Proximity Diffuse
0.787 in (20 mm) 0.787 in (20 mm) 1.57 to 2.36 in (40 to 60 mm) see Fiber Optics —
(Standard/short range)
Glass Fiber Optics Option No No Yes Yes —
Output DC DC DC DC —
Page 88 142 144 144 122

12
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide
Selection Guide

Photoelectric Sensors
XU 18 mm XU 18 mm XU 18 mm XUM XURK XURK
Laser High Excess Gain Analog Color Mark Color Mark Registration Self Teaching Color Mark
Plastic Nickel Plated Brass Nickel Plated Brass Plastic Die Cast Zinc Die Cast Zinc
— 3, 4, 4X, 6, 12, 13 3, 4, 4X (indoor), 6, 12, 13 1, 3, 4, 6, 6P, 12, 13 — —
IP67 IP67 IP67 IP67 IP67 IP67
328 ft (100 m) 229.6 ft (70 m) — — — —

— — — — — —

— — — — — —

— — 2 to 15.7 in (50 to 400 mm) 0.6 in (15 mm) 0.354 in (9 mm) 0.354 in (9 mm)

No — — No No No
DC DC PNP Analog DC DC DC
90 84 86 134 138 140

XUVK XUV XUVF XUVF


Self Teaching Label
Self Contained Fork Dynamic Fork Dynamic Frame Sensors
Detection Fork
Zinc Alloy Plastic Aluminum Aluminum
IP65 IP54 IP65 IP65
0.079 in (2 mm) 1.18 in (30 mm) 2.36 x 2.36 in (60 x 60 mm) 7.87 x 9.84 in (200 x 250 mm)

— — — —

— — — —

— — — —

No No No No
DC DC DC DC
146 148 150 152

Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156


Accessories . . . . . . . . . . . . . . . . . . . . . . . . Page 157
Beam Patterns . . . . . . . . . . . . . . . . . . . . . . Page 159
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . Page 165
Application Information . . . . . . . . . . . . Page 18, 171

13
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications

Packaging Machinery
Transparent Material Detection Opaque Color Mark Registration
Label Detection
Reading reference marks for trimming
D
L

OUTPUT
Photoelectric Sensors

XUB XUKT XUVK XURK XURK XUM


Tubular Transparent Material Self Teaching
Style Label Detection Fork Color Mark Color Mark
18 mm dia Detection Color Mark
Material Nickel Plated Brass PMMA Zinc Alloy ZAMAC Die Cast Zinc ABS/PC
Housing NEMA Type — 3, 4, 4X, 6, 12, 13 — — — 1, 3, 4, 6, 6P, 12, 13
CENELEC Type IP67 IP65 IP67 IP67 IP67 IP67
Thru-beam — — .079 in (2 mm) — — —
Maximum Retro reflective Polarized — 6 ft. (2 m) — — — —
Sensing
Range Non-polarized 39 in (99 cm) — — — — —
Proximity Diffuse (Standard/Short range) — — — .354 in (9 mm) 0.354 in (9 mm) 0.6 in (15 mm)
Glass Fiber Optics Option — — — — No –
Output DC DC DC DC DC DC
Page 92 132 146 138 140 134

Material Handling
Long Range Analog
Sensing
Detecting cakes

XU 18 mm XUC XU 18 mm XU 18 mm XUJ
High Excess
Style Laser (pair) Thru-Beam Analog Analog
Gain
Material ABS/PMMA Plastic Nickel Plated Brass Nickel Plated Brass Plastic
Housing NEMA Type – 3, 4, 4X, 6, 6P, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X (indoor), 6, 12, 13 1, 3, 6, 12, 13
CENELEC Type IP67 IP67 IP67 IP67 IP67
Thru-beam 328 ft (100 m) 196 ft (60 m) 229.6 ft (70 m) — —
Maximum Retro reflective Polarized — 29.5 ft (9 m) — — —
Sensing Non-polarized — — — — —
Range
Proximity Diffuse 2 to 15.7 in 7.87 to 31.5 in
— 3.9 ft (1.2 m) adj —
(Standard/Short Range) (50 to 400 mm) (20 to 80 mm)
Glass Fiber Optics Option No No — — —
Output DC AC/DC, DC DC PNP Analog PNP Analog
Page 90 102 84 86 110

14
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications

Ultra Violet Full Color Detection


Invisible Mark Detection

Photoelectric Sensors
XU 18 XURU XURC3 XURC4 XUFN
Fiber Optic Convergent Beam
Ultra Violet Ultra Violet Self Teach Full Color Detector
Full Color Detector Fiber Optic Cables
Nickel Plated Brass Die cast zinc Aluminum Aluminum Plastic
— — — — —
IP67 IP67 IP67 IP65 —
— — — — 1.18 in Convergent (30 mm)
— — — — —
— — — see Fiber Optics —
0.787 in (20 mm) 0.787 in (20 mm) 1.57 to 2.36 in (40 to 60 mm) see Fiber Optics —
No No Yes Yes —
DC DC DC DC —
88 142 144 144 122

Flag Detection Background Suppression Short Range


Background Suppression

XUVH XU 18 mm XUL XUJ Universal XUE XUC XUL


Classic
Self Contained Background Sub Compact Standard Long Range Compact Sub Compact
Fork Suppression Rectangular Rectangular Rectangular Universal Rectangular
ABS/PMMA Metal or Plastic ABS/PC PEI ABS Plastic ABS/PC
— 4X, 12 1, 3, 4, 6, 6P, 12, 13 1, 3, 6, 12, 13 1, 3, 4, 13 3, 4, 4X, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13
IP54 IP67 IP67 IP67 IP67 IP67 IP67
1.18 in (30 mm) — 33 ft (10 m) 42.6 ft (13 m) 203 ft (62 m) 196 ft (60 m) —
— — 16 ft (5 m) 29.5 ft (9 m) 33 ft (10 m) 29.5 ft (9 m) —
— 5.9 in (150 mm) 25 ft (8 m) 29.5 ft (9 m) 41 ft (12.5 m) — —
48 in (1.2 m) /
— 5.9 in (15 cm) 2.3 ft (.7 m) 6.6 ft (2 m) 3.9 ft (1.2 m) adj .8 ft (.25 m)
27 in (70 cm)
No No No No Yes — —
DC AC/DC, DC AC/DC, DC AC/DC, DC, Analog AC/DC, DC AC/DC, DC DC
148 74 - 77 104 108 112 102 104

15
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications

Assembly Equipment
Miniature Separate Optical Heads and Amplifiers Fiber Optics and Amplifiers
Verifying plate feed
Photoelectric Sensors

XUA Miniature XUV XUVN Classic XUD / XUD XUFN


Precision Plus
Tubular Ultra Short Amplifier for Amplifiers for Glass or Plastic Fiber Optic
Style Separate Optical Heads
8 mm dia Separate Optical Head Plastic Fiber Optics Cables
Material Nickel Plated Brass ABS — ABS —
Housing NEMA Type 4X, 6P 1, 5 — 1, 4, 13 —
CENELEC Type IP67 IP50 — IP66 —
Thru-beam 6.6 ft (2 m) — 24 ft (7.3 m) — 9.84 in (250 mm)
Maximum Retro reflective Polarized — — — — —
Sensing
Range Non-polarized — — 8 ft (2.5 m) — —
Proximity Diffuse (Standard/Short range) 1.9 in (5 cm) — — — 3.44 in (87 mm)
Glass Fiber Optics Option No — — — —
Output DC AC/DC 5 in (125 mm) DC —
Page 60 128 126 124 120

Harsh Environment
Washdown Metal Bodies

XUFA XUA Miniature Precision Classic XU 18 mm


Tubular Ultra Short Tubular
Style Glass Fiber Optic Cables
8 mm diameter 18 mm diameter
Material Glass Metal Metal
Housing NEMA Type — 4X, 6P 4X, 12
CENELEC Type — IP67 IP67
Thru-beam 54.7 in (139 cm) 13 ft (4 m) —
Maximum Retro reflective Polarized — — —
Sensing Non-polarized — — —
Range
Proximity Diffuse
7.87 in (20 cm) 2.4 in (6 cm) 5.9 in (15 cm)
(Standard/Short Range)
Glass Fiber Optics Option — No No
Output — DC AC/DC, DC
Page 116 60 62

16
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications

Specialty Fiber Optics Dynamic Sensing

Photoelectric Sensors
XUFNkP XUFNkS XUFNkT XUFNkL XUVF XUVF

High Power Soft Teflon Coated Convergent Dynamic


Dynamic Fork
Fiber Optic Cables Fiber Optic Cables Fiber Optic Cables Fiber Optic Cables Frame Sensors
Plastic Plastic Plastic with Teflon Plastic Aluminum Aluminum
— — — — — —
IP64 IP64 IP671 IP65 IP65 IP65
11.8 in (300 mm) 3.93 in (100 mm) 39.3 in (1000 mm) 59 in (1500 mm) 60 x 60 mm 200 x 250 mm
— — — — — —
— — — — — —
3.74 in (95 mm) 2.16 in (55 mm) 2.75 in (70 mm) 1.18 in (30 mm) — —
— — — — No No
— — — — DC DC
122 122 122 122 150 152

Outdoor High Temperature Corrosive Environment

XUC XUFS XUFA XUFNkT


Teflon Coated
NEMA Type 4X Outdoor Glass Fiber Optic Cables Glass Fiber Optic Cables
Fiber Optic Cables
Plastic Glass Glass Plastic with Teflon
3, 4, 4X, 6, 6P, 12, 13 — — —
IP67 — — IP67
196 ft (60 m) 9.84 in (250 mm) 28 in (70 cm) 39.3 in (1000 mm)
29.5 ft (9 m) — — —
— — — —

3.9 ft (1.2 m) adj 3.44 in (87 mm) 5.9 in (15 cm) 2.75 in (70 mm)

— — — —
AC/DC, DC — — —
102 120 116 122

Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156


Accessories . . . . . . . . . . . . . . . . . . . . . . . . Page 157
Beam Patterns . . . . . . . . . . . . . . . . . . . . . . Page 159
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . Page 165
Application Information . . . . . . . . . . . . Page 18, 171

17
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples

01: Monitoring flow of bottles 02:Verifying liquid presence in vial


Photoelectric Sensors

XU9N18•P340W XUD•003537S + XUFN12301 + XUFZ02

03: Monitoring water level in a container 04: Car washing machines

XUD•003937 + XUFN12301 XUJLN0619

05: Detecting small falling objects 06: Detecting reflective objects

XUVF••0M12 XUMH023539

18
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples

07: Monitoring height of lipsticks prior to capping 08: Monitoring flow of pallets carrying bottled water

Photoelectric Sensors
XU2B18•P340 XUJK06353

09: Monitoring flow of cans 10: Monitoring position of cheese

XUJK063539 XUL•153538

11: Verifying correct seating of screw 12: Monitoring flow of objects exiting vibrating bowl

Off On

XUD•003937 + XUFN35301 XUD•003937• + XUFN35301

19
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples

13: Detecting spring 14: Monitoring flow of printed circuit boards


Photoelectric Sensors

XUB•01353 XUM•15353•

15: Detecting dark colored objects on conveyor 16: Monitoring alignment of glass panes

XUJK703538 XUB•01353

17: Verifying plate feed 18: Verifying presence of plate

XUV•003530 + XUV-N02428 XUL•303538

20
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples

19: Indexing height of table 20: Detecting overlapping plates

Photoelectric Sensors
XUJK803538 (analog) XUL•153538

21: Indexing position of robot arms 22: Counting televisions

XUJK703538 XUL•043539

23: Verifying presence of plastic cap 24: Detecting plastic film

XU8M18PP340 + XU9N18PP340W XUB•01353

21
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples

25: Detecting label on transparent background 26: Counting tablets


Photoelectric Sensors

XUVK0252 XUV•003530

27: Verifying presence of tablets in a bottle 28: Verifying presence of label

XU2M18PP340 XUMLH0854S + XUMLH0803S

29: Verifying presence of cakes in transparent packaging 30: Detecting incorrect positioning of label

XUD•003937 + XUFN12301 + XUFZ01 XUD•003937 + XUFN05321

22
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples

31: Reading reference marks for trimming 32: Detecting “end of roll”

D
L
OUTPUT

Photoelectric Sensors
XURK0955D XUM•103535

33: Detecting cakes 34: Verifying correct positioning of labels

XUL•153538 XU2P18•P340DL

35: Verifying presence of adhesive 36: Synchronizing cutting stroke

XUD•003537• + XUFN35301 XUVH0312

23
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples

37: Monitoring position of tooth brushes 38: Monitoring stock level in hopper
Photoelectric Sensors

XUV•003530 XUD•003537

39: Monitoring cake position prior to packaging 40: Monitoring positioning of book cover

XUL•303538 + XU2M18PP340 XUM•15353R (color mark reader)

41: Detecting loop 42: Monitoring flow of cartons

XUJK803538 (analog) XULM06031

24
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples

43: Detecting bottles filled with mineral water 44: Zone surveillance

Photoelectric Sensors
XUL•153538 XU2P18•P340DL

45: Controlling parking barrier 46: Detecting persons

XULM06031H60 XULM06031H60

25
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Interpretation of Catalog Numbers
Interpretation of Catalog Numbers

X U X O A K S A T 1 6 • • • •
BODY STYLE
8mm cylindrical A
18mm cylindrical B
Stubby 40x40 C
Amplifier D
Rectangular Compact E
Fiber optic F
Compact Rectangular J
Photoelectric Sensors

Rectangular subcompact 50x50x18 K


Subcompact Rectangular L
Rectangular Miniature M
Rectangular Compact color R
Fork & Frame Detectors V
Rectangular output PE X
Accessories Z
FORMAT OR MODE
Multi-mode 0
Retro reflective 1
Thru-beam 2
Fixed Proximity Long range 3
Fixed Proximity Short range 4
Adj. Proximity Long range 5
Adj. Proximity Short range 6
Background suppression 8
Polarized Retro reflective 9
Fiber Amplifier A
Color Detection C
Glass Fiber G
Separate head H
Laser L
Plastic Fibers N
Color Contrast R
Safety S
Transparent Detection T
Amplifier heads V
Accessories Z
FAMILY TYPE OR MATERIAL
OSIRIS applications (versions) 1.9
Plastic A
Metal B
Stainless Steel S
OUTPUT
DC 3 wire PNP P
DC 3 wire NPN N
DC 3 wire PNP/NPN K
DC 2 wire D
DC 2 wire automobile C
DC analog output A
AC 2 wire F
AC/DC 2 wire M
AC/DC 2 wire SCP S
AC/DC relay R
BUS B
FUNCTION
Analog 0. . .10mA 1
Analog 4.20mA 2
N.O. A
N.C. B
N.O. + N.C. C
Programmable/wiring P
Programmable S
ADDITIONAL FUNCTIONS
No additional functions N
Time Delay T
Anti interference I
Teach M
Alarm output A
Side sensing W
CONNECTION
M8X1 (S) M 8
M12x1 (D) M 1 2
7/8 16UN (A) U 7 8
1/2 20 UNF (K) U 2 0
0.1meter cable L 0 1
2 meter cable L 2
5 meter cable L 5
10 meter cable L 1 0
0.1 meter m12 pigtail L 0 1 M 1 2
Cable entry metric 16 T 1 6
OPTIONAL
Emitter T
Receiver R

26
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Interpretation of Catalog Numbers
Interpretation of Catalog Numbers

Classic XU 18mm Tubular


Example X U 2 M 1 8 M A 2 3 • D
Photoelectric
MODE OF SENSING
Retroreflective 1
Thru-Beam 2
Proximity Diffuse 5

Photoelectric Sensors
Proximity Diffuse with Background Suppression 8
Polarized Retroreflective 9
ENCLOSURE TYPE
Plastic with Sensitivity Adjustment B
Metal with Sensitivity Adjustment M
Metal N
Plastic P
DIAMETER
18mm diameter 1 8
OUTPUT
Analog A
2 wire AC/DC M
3 wire DC, NPN N
3 wire DC, PNP P
Ultra Violet U
OPERATION MODE
Dark Operate A
Light Operate B
Light and Dark Operate P
WIRING
2 Wire 2
3 Wire 3
AC/DC without Short Circuit Protection 3
DC with Short Circuit Protection 4
MISCELLANEOUS
DC Micro Style Connector D
Laser Sensor with Micro Style Connector DL
AC/DC Micro Style Connector K
5 Meter Cable L5
10 Meter Cable L10
Separate Thru-Beam Receiver R
Separate Thru-Beam Emitter T
90 ° Side Sensing W

NOTE: These tables are intended to understand catalog number designations. They are NOT
to be used to create numbers which may not exist. Consult your local field office.

27
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
Multi-Mode Technology
Multi-Mode Technology

Principle
c A single product that automatically adapts to every use.
YW
Telemecanique offers this major innovation: Osiconcept - Offering simplicity through
innovation.
1
Photoelectric Sensors

S max.

YW
c With Osiconcept, by simply clicking on the teach button, the product is automatically
configured for optimal use based on the application.
1. Diffuse proximity sensing with no accessories.
S max.
2 2. Diffuse proximity sensing with background suppression, with no accessories.
3. Polarized retroreflexive sensing with a reflector accessory.
YW
4. Thru-beam sensing with thru-beam accessory.

3 S max.
c But in addition, Osiconcept offers:
d the maximum range for each environment,
YW
d a tenfold reduction in the number of separate products needed.

S max.
4 c The first sensor of its kind in the world for enhancing productivity.
c A complete offering that resolves the most common sensing problems:
d simplify your options,
d simplify your product inventories,
d simplify installation,
YW d simplify maintenance.

Automatic Output Activation when the Object is Present


1
YW
c All Osiconcept photoelectric sensors boast automatic activation of the output signal: when
object is present = output is activated regardless of the sensing mode used (with or without an
accessory).

2 1. Output activated
YW 2. Output activated
3. Output activated
NOTE: Reverse operation is available simply by pressing the "teach" button.
3
Installation
c 3D attachment kits provide quick installation or adjustment of Osiconcept photoelectric
sensors on 3 axes.
d These kits can also be used to install reflectors.
d They include a set of brackets, screws and covers that can be used to install all new
enclosures in the Osiris product line.

28
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
Multi-Mode Technology
XS Inductive Sensors - Auto-Adaptable Technology

Cylindrical
Dimensions " (mm) 0.71 (18)

Photoelectric Sensors
Applications Machine Building, Packaging, Counting, Conveyor
Ranges in Meters
with emitter accessory 20
with reflector accessory 4
diffuse without accessory 0.4
Diffuse w/bgs without accessory 0.12
Body style XUB
Pages 30
Rectangular
Dimensions " (mm) 0.47 x 1.3 x 0.78 (12 x 34 x 20) 0.7 x 1.9 x 1.9 (18 x 50 x 50) 1.2 x 4.5 x 3.4 (30 x 114 x 87.5)

520220
501542_1

805167
Applications Packaging, Counting access Control, Conveyor
Range in Meters
with emitter accessory 18 35 60
with reflector accessory 4 5.7 15
diffuse without accessory0.02 0.55 1.2 3
Diffuse w/bgs without accessory 0.10 0.3 1.3
Body style XUM XUK XUX
Pages 46 50 54
A complete offer structured to the specific needs of the market today.
• Multi-Mode Detectors - Products for multiple functions.
• General Detectors - Product with essential functions for minimum cost.
• Application Specific - Products designed to perform the most difficult applications to the end users requirements.

29
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode Front Sensing, DC
18 mm Plastic Tubular / Multi-Mode Front Sensing, DC

Features:
• Ability to select sensing mode (Diffuse, Diffuse w/Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0•••••NL2
• Housing: Plastic
Photoelectric Sensors

• Light (N.C.) / Dark (N.O.) selectable


Circuit Voltage Connection Load Current Operating
Output Mode Catalog Number
Type Range Type d Maximum Frequency Maximum
N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0APSNL2
N.C. / N.O. PNP 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0APSNM12
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0ANSNL2
XUB0••••NM12 N.C. / N.O. NPN 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0ANSNM12

Accessories
thread Description Connection Type Catalog Number
M18x1 Reflector – XUZC50
2m (6.6’) cable XUB0AKSNL2T
Transmitter
4 pin micro connector XUB0AKSNM12
a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix.
Dimensions

Variation of Usable Sensing Distance


Diffuse System with Adjustable Background Suppression
b
Learning at Minimum Learning at Maximum
a
B B
Cable Connector A-B: Object Reflection Coefficient
a b a b Black 6%
Gray 18%
∅ 18 White 90%
Front 2.5 (64) 1.7 (44) 3.1 (78) 1.7 (44) Sensing Range
Sensing Non-sensing Zone (matt surfaces)
A 0,01 0,07 0,1 A 0,01 0,11 0,15 S (m)
S (m)
0,08 0,12
Dimension “a” for XUB0...T is 2.4 (62) / 3.0 (76).

inches (mm)
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

30
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode Front Sensing, DC
18 mm Plastic Tubular / Multi-Mode Front Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse Background Supp. 12 cm
1 (+) Sensing Distance (Sn) Diffuse Standard 30 cm
4 Output (excess gain = 2)
1 2
Polarized Retroreflective 2m
2 Test
Thru-Beam 15 m
Cable

Photoelectric Sensors
PNP Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
(-) Blue
BN/1 + Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
PNP BK/4
(+) Brown NEMA Type 4X (indoor), 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67 Double Insulated
Beam Break Test Violet
Case PBT
NPN Emitter
Enclosure Material Lens PMMA
BN/1 + 1/BN Cable PVR
NPN
BK/4 2/VI
3/BU Mounting nuts 5 N•m (44.4 lb-in)
Maximum Tightening Torque
BU/3 – Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
Output Yellow
LED indicator Signal instability Red
Power & teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA (20mA – XUB0…T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799

Agency Listings
®

Accessories
Description Catalog Number
Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
XUZC50 XUZB2003 Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.

Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory

6
15
Ø 12 mm 4
2
40
10 15 20 m -2 0,2 4 m
0,8
-15 3
-4
-6
3

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

31
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Plastic Tubular / Multi-Mode 90 Degree Side Sensing, DC

Features:
550001

• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0••••WL2 • Housing: Plastic
Photoelectric Sensors

• Light(N.C.)/Dark(N.O.) selectable
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Type Range Type d Maximum Maximum
N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0APSWL2
N.C. / N.O. PNP 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0APSWM12
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0ANSWL2
N.C. / N.O. NPN 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0ANSWM12

Accessories
XUB0•••••WM12
Description Connection Type Catalog Number
thread Reflector – XUZC50
M18x1 2 m (6.6’) cable XUB0AKSWL2T
Transmitter
4 pin micro conn XUB0AKSWM12
a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix.
Dimensions

Variation of Usable Sensing Distance


Diffuse System with Adjustable Background Suppression
b Learning at Minimum Learning at Maximum
a
B B
Cable Connector A-B: Object Reflection Coefficient
Black 6%
a b a b Gray 18%
∅ 18 White 90%
90° Side 3.1 (78) 1.7 (44) 3.6 (92) 1.7 (44) Sensing Range
Sensing Non-sensing Zone (matt surfaces)
A 0,01 0,07 0,1 A 0,01 0,11 0,15 S (m)
S (m)
0,08 0,12
inches (mm)

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

32
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Plastic Tubular / Multi-Mode 90 Degree Side Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse Background Supp. 12 cm
1 (+) Diffuse Standard 20 cm
Sensing Distance (Sn)
4 Output
(excess gain - 2_ Polarized Retroreflective 1.5 m
1 2 2 Test
Thru-Beam 10 m
Cable PNP

Photoelectric Sensors
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
BN/1 + Temperature Range
(-) Blue PNP BK/4
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
(+) Brown NEMA Type 4X (indoor), 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67 Double Insulated
Beam Break Test Violet
Case PBT
NPN Emitter
Enclosure Material Lens PMMA
BN/1 +
NPN 1/BN Cable PVR
BK/4 2/VI
3/BU Mounting nuts 5 N•m (44.4 lb-in)
BU/3 – Maximum Tightening Torque
Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
Output Yellow
LED indicator Signal instability Red
Power & teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35mA (20mA – XUB0…T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799

Agency Listings
®

Accessories
Description Catalog Number
Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
XUZB2003
XUZC50 Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.

Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory

6
15
Ø 12 mm 4
2

10 15 20 m 40
-2 0,2 4 m
0,8
-15 3
-4
-6
3

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

33
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode Front Sensing, DC
18 mm Metal Tubular / Multi-Mode Front Sensing, DC

Features:
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0•••••ML2
• Housing: Metal
Photoelectric Sensors

thread • N.C. / N.O. selectable


M18x1
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Type Range Type d Maximum Maximum
N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0BPSNL2
N.C. / N.O. PNP 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0BPSNM12
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0BNSNL2
N.C. / N.O. NPN 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0BNSNM12
XUB0••••NM12
Accessories
Description Connection Type Catalog Number
Reflector – XUZC50
2 m (6.6’) cable XUB0BKSNL2T
Transmitter
4 pin micro connector XUB0BKSNM12
Dimensions a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix.

b
a Variation of Usable Sensing Distance
Diffuse System with Adjustable Background Suppression
Cable Connector
Learning at Minimum Learning at Maximum
a b a b
B B
∅ 18
Front 2.5 (64) 1.7 (44) 3.1 (78) 1.7 (44) A-B: Object Reflection Coefficient
Sensing Black 6%
Gray 18%
White 90%
Dimension “a” for XUB0...T is 2.4 (62) / 3.0 (76).
Sensing Range
Non-sensing Zone (matt surfaces)
inches (mm) A 0,01 0,07 0,1 A 0,01
S (m) 0,11 0,15 S (m)
0,08 0,12

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

34
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode Front Sensing, DC
18 mm Metal Tubular / Multi-Mode Front Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse w/ Background Supp. 12 cm
1 (+) Standard Diffuse 30 cm
Sensing Distance (Sn)
4 Output
(excess gain = 2) Pol. Retroreflective 2m
1 2 2 Test
Thru-Beam 15 m
Cable PNP

Photoelectric Sensors
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
BN/1 + Temperature Range
(-) Blue Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
PNP BK/4
(+) Brown NEMA Type 4X, 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67
Beam Break Test Violet
Case Nickel Plated Brass
NPN Emitter
Enclosure Material Lens PMMA
BN/1 +
NPN 1/BN Cable PVR
BK/4 2/VI
3/BU Mounting nuts 15 N•m (133.3 lb-in)
– Maximum Tightening Torque
BU/3 Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
Output Yellow
LED indicator Signal instability Red
Power & teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA (20 mA – XUB0….T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799

Agency Listings
®

Accessories
Description Catalog Number
Reflector 50x50 mm XUZC50
90 ° metal mounting bracket XUZA118
XUZB2003
XUZC50 Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.

Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory

6
15
Ø 12 mm 4
2

10 15 20 m 40
-2 0,2 4 m
0,8
-15 3
-4
-6
3

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

35
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Metal Tubular / Multi-Mode 90 Degree Side Sensing, DC

Features:
550001

• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0••••WL2 • Housing: Metal
Photoelectric Sensors

thread
M18x1
• N.C. / N.O. selectable
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Type Range Type d Maximum Maximum
N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0BPSWL2
N.C. / N.O. PNP 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0BPSWM12
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0BNSWL2
N.C. / N.O. NPN 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0BNSWM12

Accessories
XUB0•••••WM12 Description Connection Type Catalog Number
Reflector – XUZC50
2 m (6.6’) cable XUB0BKSWL2T
Transmitter
4 pin micro connector XUB0BKSWM12

Dimensions a Transmitter required for multi-mode receiver to operate in Thru-beam mode


c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix / 10 m cable length available with L10 suffix.

b
Variation of Usable Sensing Distance
a
Diffuse System with Adjustable Background Suppression
Cable Connector Learning at Minimum Learning at Maximum
a b a b B B
∅ 18 A-B: Object Reflection Coefficient
90° Side 3.1 (78) 1.7 (44) 3.6 (92) 1.7 (44) Black 6%
Sensing Gray 18%
White 90%
inches (mm)
Sensing Range
Non-sensing Zone (matt surfaces)
A 0,01 0,07 0,1 A 0,01 0,11 0,15 S (m)
S (m)
0,08 0,12

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

36
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Metal Tubular / Multi-Mode 90 Degree Side Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse Background Supp. 12 cm
1 (+) Standard Diffuse 20 cm
Sensing Distance (Sn)
4 Output
(excess gain = 2) Pol. Retroreflective 1.5 m
1 2 2 Test
Thru-Beam 10 m
Cable PNP

Photoelectric Sensors
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
BN/1 + Temperature Range
(-) Blue Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
PNP BK/4
(+) Brown NEMA Type 4X, 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67
Beam Break Test Violet
Case Nickel Plated Brass
NPN Emitter
Enclosure Material Lens PMMA
BN/1 +
NPN 1/BN Cable PVR
BK/4 2/VI
3/BU Mounting nuts 15 N•m (133.3 lb-in)
– Maximum Tightening Torque
BU/3 Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
Output Yellow
LED indicator Signal Instability Red
Power & Teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35mA
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799

Agency Listings
®

Accessories
Description Catalog Number
Reflector 50x50 mm XUZC50
90 ° metal mounting bracket XUZA118
XUZC50 XUZB2003
Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.

Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory

6
15
Ø 12 mm 4
2

10 15 20 m 40
-2 0,2 4 m
0,8
-15 3
-4
-6
3

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

37
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Plastic Tubular
Front Sensing, DC
18 mm Plastic Tubular / Front Sensing, DC

thread Features:
M18x1
• Housing: Plastic
• Mounting Nuts included
• UL Listed, CSA Certified
XUB•A•••••WL2 • CE Marked
Photoelectric Sensors

Circuit Voltage Connection Load Current Operating


Output Mode Catalog Number
Type Range Type a Max. Frequency
Thru-Beam (receiver) – 15 m (48’) Nominal Sensing Distance (emitter sold separately)
550009

N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2APANL2R


N.C PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2APBNL2R
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2ANANL2R
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2ANBNL2R
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2APANM12R
N.C PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2APBNM12R
XUB•A••NM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2ANANM12R
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2ANBNM12R
Thru-Beam (emitter)
– – 12-24 Vdc 2 m (6.6’) cable – – XUB2AKSNL2T
– – 12-24 Vdc 4 pin Micro conn. – – XUB2AKSNM12T
Retroreflective – 4 m (13’) Nominal Sensing Distance (reflector sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1APANL2
Dimensions N.C PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1ANBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1APANM12
b N.C PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1APBNM12
a N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1ANANM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1ANBNM12
Cable Connector
Polarized Retroreflective – 2 m (6.6’) Nominal Sensing Distance
a b a b N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9APANL2
∅ 18 N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9APBNL2
Front 1.8 (46) 1.1 (28) 2.4 (60) 1.1 (28) N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9ANANL2
Sensing
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9ANBNL2
18 mm N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9APANM12
2.5 (62) 1.7 (44) 3.0 (76) 1.7 (44)
XUB5
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9APBNM12
Dimension “a” for XUB9 is 1.9 (48) / 2.4 (62). N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9ANANM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9ANBNM12
inches (mm)
Fixed Proximity Diffuse – 10 cm (4") Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4ANBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4APANM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4APBNM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4ANANM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4ANBNM12
Adjustable Proximity Diffuse – 60 cm (23.6") Nominal sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5ANBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5APANM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5APBNM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5ANANM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5ANBNM12
a 5m cable length available with L5 suffix.

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

38
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Plastic Tubular
Front Sensing, DC
18 mm Plastic Tubular / Front Sensing, DC

Specifications
Wiring
Mechanical
Connector For usable sensing range, see detection curves
4 3 3 (-) Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
1 (+) Temperature Range
4 Output Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 2
2 Test NEMA Type 4X (indoor), 12
Enclosure Rating
Cable IEC Type IP67 Double Insulated
PNP

Photoelectric Sensors
Case PBT
(-) Blue BN/1 +
PNP BK/4 (NO/NC) Enclosure Material Lens PMMA
(+) Brown
(Output) Black – Cable PVR
BU/3
Beam Break Test Violet Mounting nuts 5 N•m (44.4 lb-in)
Maximum Tightening Torque
NPN Connector 2 N•m (17.7 lb-in)
BN/1 + Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
NPN
BK/4 (NO/NC) Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
BU/3 – LED indicator Output Yellow
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Emitter Connection
Connector 4 pin Micro style DC (M12)
1/BN
2/VI Electrical
3/BU
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
E
Agency Listings
®

XUZA118 XUZA218
Accessories
805799

Description Catalog Number


Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
Plastic clamp mounting bracket XUZA218
3-D mounting bracket (Stem nut included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Plastic Mounting Nuts XSZE218
XUZC50
XUZB2003 See page 94 for complete 3-D assembly.

Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity

6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m

Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

39
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Plastic Tubular
90 Degree Side Sensing, DC
18 mm Plastic Tubular / 90 Degree Side Sensing, DC

Features:
550001

• Housing: Plastic
• Mounting Nuts included
• UL Listed, CSA Certified
• CE Marked
XUB•A••••WL2
Photoelectric Sensors

thread Circuit Voltage Connection Load Current Operating


Output Mode Catalog Number
M18x1 Type Range Type a Max. Frequency
Thru-Beam (receiver) – 15 m (48’) Nominal Sensing Distance (emitter sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2APAWL2R
550010

N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2APBWL2R


N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2ANAWL2R
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2ANBWL2R
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2APAWM12R
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2APBWM12R
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2ANAWM12R
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2ANBWM12R
XUB•A••WM12
Thru-Beam (emitter)
– – 12-24 Vdc 2 m (6.6’) cable – – XUB2AKSWL2T
– – 12-24 Vdc 4 pin Micro conn. – – XUB2AKSWM12T

Dimensions Retroreflective – 4 m (13’) Nominal Sensing Distance (reflector sold separately)


N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1APAWL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1APBWL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1ANAWL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1ANBWL2
b N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1APAWM12
a N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1APBWM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1ANAWM12
Cable Connector N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1ANBWM12
a b a b Polarized Retroreflective – 2 m (6.6’) Nominal Sensing Distance
∅ 18 N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9APAWL2
90 ° Side 2.4 (62) 1.1 (28) 3.0 (76) 1.1 (28) N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9APBWL2
Sensing
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9ANAWL2
18 mm N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9ANBWL2
3.0 (78) 1.7 (44) 3.6 (92) 1.7 (44)
XUB5 N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9APAWM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9APBWM12
inches (mm)
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9ANAWM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9ANBWM12
Fixed Proximity Diffuse – 10 cm (4") Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4APAWL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4APBWL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4ANAWL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4ANBWL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4APAWM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4APBWM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4ANAWM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4ANBWM12
Adjustable Proximity Diffuse – 60 cm (23.6") Nominal sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5APAWL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5APBWL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5ANAWL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5ANBWL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5APAWM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5APBWM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5ANAWM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5ANBWM12

a 5m cable length available with L5 suffix.

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

40
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Plastic Tubular
90 Degree Side Sensing, DC
18 mm Plastic Tubular / 90 Degree Side Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
4 3 3 (-) Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
4 Output NEMA Type 4X (indoor), 12
1 2 Enclosure Rating
2 Test IEC Type IP67 Double Insulated
Case PBT

Photoelectric Sensors
Cable PNP
Enclosure Material Lens PMMA
(-) Blue BN/1 + Cable PVR
PNP BK/4 (NO/NC)
(+) Brown
Mounting nuts 5 N•m (44.4 lb-in)
(Output) Black – Maximum Tightening Torque
BU/3 Connector 2 N•m (17.7 lb-in)
Beam Break Test Violet
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
NPN Emitter
Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
BN/1 + 1/BN LED indicator Output Yellow
NPN
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor 0.34 mm2
– Connection
BU/3 Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes

Agency Listings
®

Accessories
Description Catalog Number
XUZA118 XUZA218 Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
805799

Plastic clamp mounting bracket XUZA218


3-D mounting bracket (Stem nut included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Plastic Mounting Nuts XSZE218
See page 94 for complete 3-D assembly.

XUZC50
XUZB2003

Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity

6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m

Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

41
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Metal Tubular
Front Sensing, DC
18 mm Metal Tubular / Front Sensing, DC

thread
Features:
M18x1 • Housing: Metal
• Mounting Nuts included
• UL Listed, CSA Certified

XUB•B•••••L2
• CE Marked
Photoelectric Sensors

Circuit Voltage Connection Load Current Operating


Output Mode Catalog Number
Type Range Type * Max. Frequency
Thru-Beam (receiver) – 15 m (48’) Nominal Sensing Distance (emitter sold separately)
550009

N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BPANL2R


N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BPBNL2R
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BNANL2R
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BNBNL2R
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BPANM12R
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BPBNM12R
XUB•B••NM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BNANM12R
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BNBNM12R
Thru-Beam (emitter)
– – 12-24 Vdc 2 m (6.6’) cable – – XUB2BKSNL2T
– – 12-24 Vdc 4 pin Micro conn. – – XUB2BKSNM12T
Retroreflective – 4 m (13’) Nominal Sensing Distance (reflector sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BPANL2
Dimensions N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BPBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BNANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BNBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BPANM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BPBNM12
b
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BNANM12
a
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BNBNM12

Cable Connector Polarized Retroreflective – 2 m (6.6’) Nominal Sensing Distance


N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BPANL2
a b a b
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BPBNL2
∅ 18
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BNANL2
Front 1.8 (46) 1.1 (28) 2.4 (60) 1.1 (28)
Sensing N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BNBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BPANM12
18 mm
2.5 (62) 1.7 (44) 3.0 (76) 1.7 (44) N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BPBNM12
XUB5
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BNANM12
Dimension “a” for XUB9 is 1.9 (48) / 2.4 (62).
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BNBNM12
inches (mm) Fixed Proximity Diffuse – 10 cm (4") Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BPANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BPBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BNANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BNBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BPANM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BPBNM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BNANM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BNBNM12
Adjustable Proximity Diffuse – 60 cm (23.6") Nominal sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BPANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BPBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BNANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BNBNL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BPANM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BPBNM12
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BNANM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BNBNM12
a 5m cable length available with L5 suffix.

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

42
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Metal Tubular
Front Sensing, DC
18 mm Metal Tubular / Front Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
4 3 3 (-) Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
4 Output NEMA Type 4X, 12
1 2
2 Test Enclosure Rating
IEC Type IP67 Double Insulated
Cable Case Nickel Plated Brass

Photoelectric Sensors
PNP
Enclosure Material Lens PMMA
(-) Blue BN/1 +
PNP BK/4 (NO/NC) Cable PVR
(+) Brown
(Output) Black Mounting nuts 15 N•m (133.3 lb-in)
BU/3 – Maximum Tightening Torque
Beam Break Test Violet Connector 2 N•m (17.7 lb-in)
NPN Emitter Vibration Resistance (IEC 60068-2-6) 7 gn, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BN/1 + 1/BN
NPN LED indicator Output Yellow
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor 0.34 mm2
BU/3 – Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes

Agency Listings
®

Accessories
Description Catalog Number
XUZA118 XUZA218 Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
805799

Plastic clamp mounting bracket XUZA218


3-D mounting bracket (Stem nut included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Metal Mounting Nuts XSZE108
See page 94 for complete 3-D assembly.

XUZC50
XUZB2003

Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity

6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m

Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

43
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Metal Tubular
90 Degree Side Sensing, DC
18 mm Metal Tubular / 90 Degree Side Sensing, DC

Features:
550001

• Housing: Metal
• Mounting Nuts included
• UL Listed, CSA Certified
• CE Marked
XUB•B••••WL2
Photoelectric Sensors

thread Circuit Voltage Connection Load Current Operating


Output Mode Catalog Number
Type Range Type a Max. Frequency
M18x1
Thru-Beam (receiver) – 15 m (48’) Nominal Sensing Distance (emitter sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BPAWL2R
550010

N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BPBWL2R


N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BNAWL2R
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB2BNBWL2R
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BPAWM12R
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BPBWM12R
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BNAWM12R
XUB•B••WM12 N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB2BNBWM12R
Thru-Beam (emitter)
– – 12-24 Vdc 2 m (6.6’) cable – – XUB2BKSWL2T
– – 12-24 Vdc 4 pin Micro conn. – – XUB2BKSWM12T
Retroreflective – 4 m (13’) Nominal Sensing Distance (reflector sold separately)
Dimensions N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BPAWL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BPBWL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BNAWL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB1BNBWL2
N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BPAWM12
b
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BPBWM12
a
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BNAWM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB1BNBWM12
Cable Connector

a b a b
Polarized Retroreflective – 2 m (6.6’) Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BPAWL2
∅ 18
90 ° Side 2.4 (62) 1.1 (28) 3.0 (76) 1.1 (28) N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BPBWL2
Sensing N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BNAWL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BNBWL2
18 mm
3.0 (78) 1.7 (44) 3.6 (92) 1.7 (44)
XUB5 N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BPAWM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BPBWM12
inches (mm)
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BNAWM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BNBWM12
Fixed Proximity Diffuse – 10 cm (4") Nominal Sensing Distance
N.O.) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BPAWL2
N.C) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BPBWL2
N.O.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BNAWL2
N.C.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BNBWL2
N.O.) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BPAWM12
N.C) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BPBWM12
N.O.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BNAWM12
N.C.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BNBWM12
Adjustable Proximity Diffuse – 60 cm (23.6") Nominal sensing Distance
N.O.) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BPAWL2
N.C) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BPBWL2
N.O.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BNAWL2
N.C.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BNBWL2
N.O.) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BPAWM12
N.C) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BPBWM12
N.O.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BNAWM12
N.C.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BNBWM12
a 5 m cable length available with L5 suffix.

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

44
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Metal Tubular
90 Degree Side Sensing, DC
18 mm Metal Tubular / 90 Degree Side Sensing, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
3 (-) Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
4 3 Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
4 Output NEMA Type 4X, 12
1 2
2 Test Enclosure Rating
IEC Type IP67 Double Insulated
Cable Case Nickel Plated Brass

Photoelectric Sensors
PNP
Enclosure Material Lens PMMA
(-) Blue BN/1 +
PNP BK/4 (NO/NC) Cable PVR
(+) Brown
(Output) Black Mounting nuts 15 N•m (133.3 lb-in)
BU/3 – Maximum Tightening Torque
Beam Break Test Violet Connector 2 N•m (17.7 lb-in)
NPN Emitter Vibration Resistance (IEC 60068-2-6) 7 gn, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BN/1 + 1/BN
NPN LED indicator Output Yellow
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor
BU/3 – Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes

Agency Listings
®

Accessories
Description Catalog Number
XUZA118 XUZA218 Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
805799

Plastic clamp style mounting bracket XUZA218


3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Metal Mounting Nuts XSZE108
See page 94 for complete 3-D assembly.

XUZC50 XUZB2003

Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity

6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m

Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

45
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
XUM Miniature Rectangular
Multi-Mode, DC
XUM Miniature Rectangular / Multi-Mode, DC

Features:
501542_1

• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
• Housing: Plastic
Photoelectric Sensors

XUM OA••L2
• N.C. / N.O. selectable
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
501543_1

Type Range Type d Maximum Maximum


N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUM0APSAL2
N.C. / N.O. PNP 12-24 Vdc M8 Nano conn. 100 mA 250 Hz XUM0APSAM8
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUM0ANSAL2
N.C. / N.O. NPN 12-24 Vdc M8 Nano conn. 100 mA 250 Hz XUM0ANSAM8

Accessories
XUM OA••M8 Description Connection Type Catalog Number
Reflector – XUZC50
2 m (6.6’) cable XUM0AKSAL2T
Transmitter
M8 Nano connector XUM0AKSAM8T
a Transmitter required for multi-mode receiver to operate in Thru-beam mode
Dimensions c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix / 10 m cable length available with L10 suffix.
XUM

Ø3
Variation of Usable Sensing Distance
Diffuse System with Adjustable Background Suppression
25.5

1.3
1.0

34

Learning at Minimum Learning at Maximum

B B
0.47
A-B: Object Reflection Coefficient
12
0.78 Black 6%
20 Gray 18%
White 90%
Sensing Range
Ø3 A 0,01 0,05 0,08 Non-sensing Zone (matt surfaces) A 0,01
S (m) 0,08 0,15 S (m)
0,06 0,10
1.3
1.7 34
25.5
1.0

45

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
0.78 0.47 modes.
20 12

Dual Dimensions inches


mm

46
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
XUM Miniature Rectangular
Multi-Mode, DC
XUM Miniature Rectangular / Multi-Mode, DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector Diffuse Background Supp. 10 cm
2 4 3 (-)
Sensing Distance (Sn) Diffuse Standard 40 cm
1 (+)
1 3 4 Output (excess gain = 2) Pol. Retroreflective 3m
2 Alarm or Test Thru-Beam 14 m
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)

Photoelectric Sensors
Cable Temperature Range
PNP Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
(-) Blue BN/1 + NEMA Type 1, 3, 4, 6, 6P (cable version only), 12, 13
(+) Brown PNP Enclosure Rating
BK/4 WH/2 IEC Type IP67
(Output) Black
Alarm White – Case PBT
BU/3
Beam Break Test Violet Enclosure Material Lens PMMA
Cable PVR
NPN Emitter
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
BN/1 +
NPN 1/BN Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
BK/4 WH/2 2/VI
3/BU Output Yellow
BU/3 –
LED indicator Power & Teach Green
520313

Signal Instability Red


Cable 4.2 mm O.D. 4 conductor
Connection
Connector 4 pin Nano conn. M8
Electrical
805799

Voltage Range 12 – 24 Vdc


Voltage Limit (including ripple) 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA (20 mA – XUM0…T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
XUZC50 Off Delay Maximum 2 ms
Power up Delay Maximum 100 ms
Alarm Output 50 mA
550014

Polarized - red 660 nm


Wavelength Short Range Proximity 660 nm
All others 880 nm
Reverse Polarity Protection Yes
Protective Circuitry Overload Protection Yes
Short Circuit Protection-SCP Yes

XUZM2003 XUZ2001 Agency Listings


®

Accessories
550015

Description Catalog Number


Reflector 50x50 mm XUZC50
3-D mounting bracket (stem not included) XUZM2003
3-D Protective mounting bracket (stem not included) XUZM2004
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Metal Mounting Nuts XSZE108
XUZM2004 See page 159 for complete 3-D assembly.

Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory

10 2 6
Ø 10 mm 4
1 0,30 2

10 14 m 0,55 m 3 4 m
-1 -2 0,2
0,1
-10 -2 -4
-6 Sn 3m
Sn 10 m Sn 0,4 m

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M8 or S suffix)


XSZCS141 Nano conn., 4 pin, 2m, straight
XSZCS151 Nano conn., 4 pin, 2m 90 °
For additional cable options and lengths see p. 518

47
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM Miniature Rectangular
DC
XUM Miniature Rectangular / DC

Optimum miniature rectangular photoelectric sensors designed for OEMs & industrial applications.
550023

Features:
• Small dimensions, designed to fit in those tight applications
• Quick connect versions
• Available in either N.C. or N.O. operation
XUM •A••L2
Photoelectric Sensors

Circuit Voltage Connection Load Current Operating Frequency


Output Mode Catalog Number
Type Range Type a Maximum Maximum
Thru-Beam (receiver) - 8 m (26’) Nominal Sensing Distance (emitter sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 400 Hz XUM2APANL2R
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 400 Hz XUM2APBNL2R
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 400 Hz XUM2ANANL2R
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 400 Hz XUM2ANBNL2R
N.O. PNP 12-24 Vdc M 8 Nano conn. 100 mA 400 Hz XUM2APANM8R
N.C. PNP 12-24 Vdc M 8 Nano conn. 100 mA 400 Hz XUM2APBNM8R
N.O. NPN 12-24 Vdc M 8 Nano conn. 100 mA 400 Hz XUM2ANANM8R
N.C. NPN 12-24 Vdc M 8 Nano conn. 100 mA 400 Hz XUM2ANBNM8R
Thru-Beam (emitter)
– – 12-24 Vdc 2 m (6.6’) cable – – XUM2AKSNL2T
– – 12-24 Vdc M 8 Nano conn. – – XUM2AKSNM8T
Retroreflective - 4 m (13’) Nominal Sensing Distance (reflector sold separately)
Dimensions N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM1APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM1APBNL2
XUM N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM1ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM1ANBNL2
1.06 Ø3 0.5
N.O. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM1APANM8
0.15

27 12
N.C. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM1APBNM8
4

N.O. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM1ANANM8


0.7 34 0.1
3.5

N.C. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM1ANBNM8


0.3
1.3

5 1.0 8

Polarized Retroreflective - 2 m (6.6’) Nominal Sensing Distance (reflector sold separately)


25.5
17.5

N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM9APANL2


Ø3 N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM9APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM9ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM9ANBNL2
N.O. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM9APANM8
Dual Dimensions inches N.C. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM9APBNM8
mm
N.O. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM9ANANM8
N.C. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM9ANBNM8
Adjustable Short Range Proximity Diffuse – 10 cm (4') Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM6APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM6APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM6ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM6ANBNL2
N.O. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM6APANM8
N.C. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM6APBNM8
N.O. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM6ANANM8
N.C. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM6ANBNM8
Adjustable Long Range Proximity Diffuse – 40 cm (16') Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM5APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM5APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM5ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUM5ANBNL2
N.O. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM5APANM8
N.C. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM5APBNM8
N.O. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM5ANANM8
N.C. NPN 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM5ANBNM8
a 5 m cable length available with L5 suffix.

48
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM Miniature Rectangular
DC
XUM Miniature Rectangular / DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
3 (-) Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
2 4 Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 3 4 Output
NEMA Type 1, 3, 4, 4X (indoor), 6, 6P (cable version only), 12, 13
2 Test Enclosure Rating
IEC Type IP67
Cable PNP

Photoelectric Sensors
Case PBT
(-) Blue
BN/1 + Enclosure Material Lens PMMA
PNP BK/4 (NO/NC)
(+) Brown Cable PVR
(Output) Black –
BU/3 Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Beam Break Test Violet
Shock Resistance (IEC 60067-2-27) 30 g duration 11 ms
NPN Emitter
Output Yellow
BN/1 + LED indicator
NPN 1/BN Power Green (XUM2…T)
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor
BU/3 – Connection
Connector 4 pin Nano style DC (M8)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz (400 Hz Thru-Beam)
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 30 ms
Polarized - red 660 nm
Wavelength Short Range Proximity 660 nm
All others 880 nm
Overload Protection Yes
Protective Circuitry
Short Circuit Protection Yes

Agency Listings
®

Accessories
Description Sensing Distance Catalog Number
90 ° mounting bracket (cable version) – XUZA47
90 ° mounting bracket (connector version) – XUZA46
0.5 mm diameter 4.5 cm (1.78") XUMZ01
Thru-beam aperture 1.0 mm diameter 4.5 cm (1.78") XUMZ02
XUMZ0k 2.0 mm diameter 4.5 cm (1.78") XUMZ03
Thru-Beam Aperture
Detection Curves
Thru-Beam System Diffuse Diffuse Polarized Retroreflective Retroreflective
Long Range Short Range

8 1
2 1 6 6
Ø 6 mm 2 2 2 4 4
1 1 2 2
0,1
8 m m
-2 0,2 2 -2 0,2
0,6 m 0,15 m 4
-1 -1 -4 -4
-8 0,1 0,2 0,025 -6 -6
-2 -2 Sn 2m Sn 4m
Sn 8m
Sn 0,4 m Sn 0,1 m

Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %, 2 : Gray 18 % With Reflector XUZ C50 With Reflector XUZ C50

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

Connector Cables (M8 or S suffix)


XSZCS141 Nano conn., 4 pin, 2m, straight
XSZCS151 Nano conn., 4 pin, 2m 90 °
For additional cable options and lengths see p. 518

49
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
XUK Subcompact Rectangular
Multi-Mode, DC and AC/DC
XUK Subcompact Rectangular / Multi-Mode, DC and AC/DC

Features:
805167

• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Pol.
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
• Housing: Plastic
Photoelectric Sensors

XUK 0AKSAL2
• N.C. / N.O. selectable
805166

Operating
Circuit Voltage Connection Load Current
Output Mode Frequency Catalog Number
Type Range Type d Maximum
Maximum
N.C. / N.O. PNP/NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK0AKSAL2
N.C. / N.O. PNP/NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK0AKSAM12
N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK0ARCTL2

XUK 0AKSAM12 Accessories


Description Connection Type Catalog Number
Reflector – XUZC50
12-240 Vdc 2 m (6.6’) cable XUK0AKSAL2T
Transmitter 12-240 Vdc 4 pin micro conn. XUK0AKSAM12T
Dimensions 24-240 Vac/dc 2 m (6.6’) cable XUKARCTL2T

XUK a Transmitter required for multi-mode receiver to operate in Thru-beam mode


c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
1.96 d 10 m cable length available with L10 suffix.
50 1.57 Ø 4.5
40
0.78

Variation of Usable Sensing Distance


20 1.96 20
1.57
40

50
0.78

Diffuse System with Adjustable Background Suppression


Learning at Minimum Learning at Maximum

0.7
18 B
A-B: Object Reflection Coefficient B
Black 6%
Gray 18%
Dual Dimensions inches White 90%
mm
Sensing Range
A 0,01 0,05 0,08
S (m)
Non-sensing Zone (matt surfaces) A 0,02 0,26 0,38 S (m)
0,06 0,3

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

50
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
XUK Subcompact Rectangular
Multi-Mode, DC and AC/DC
XUK Subcompact Rectangular / Multi-Mode, DC and AC/DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
Diffuse Background Supp. 30 cm
3 (-)
4 3
1 (+) Sensing Distance (Sn) Diffuse Standard 1m
4 Output (excess gain = 2) Pol. Retroreflective 4m
1 2
2 Alarm or Test Thru-Beam 30 m
Cable Operating -13 ° to +131 ° F (-25 ° to +55 ° C)

Photoelectric Sensors
PNP Temperature Range
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
(-) Blue BN/1 + NEMA Type 4, 4X (indoor), 12, 13
(+) Brown PNP
BK/4 WH/2 Enclosure Rating
(Output) Black IEC Type IP65
Alarm White BU/3 – Case PBT
Beam Break Test Violet Enclosure Material Lens PMMA
NPN Emitter Cable PVR
BN/1 + Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
NPN 1/BN
BK/4 WH/2 2/VI Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
3/BU Output Yellow
BU/3 –
LED indicator Signal Instability Red
Cable Power & Teach Green
Common White Cable 4.2 mm O.D. 4, 5 conductor
Blue N.O. Black Connection
Brown N.C. Gray Connector (DC version) 4 pin Micro style DC (M12)
Electrical AC/DC DC
Emitter
Voltage Range 24-240 Vac/dc 12 – 24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 2V 2V
Current Consumption (no load) maximum 3W 10 mA
Load Current maximum 3A 100 mA
Maximum Operating Frequency 30 Hz 250 Hz
On Delay Maximum 25 ms 20 ms
550028

550029

Off Delay Maximum 25 ms 20 ms


Power up Delay Maximum 200 ms 300 ms
Overload Protection Yes Yes
Protective Circuitry Reverse Polarity Protection – Yes
Short Circuit Protection – Yes

Agency Listings
XUZK2003 XUZK2004 ®

Accessories
550030

Description Catalog Number


805799

Reflector 50x50mm XUZC50


90 ° metal mounting bracket XUZA51
3-D mounting bracket (stem not included) XUZK2003
3-D protective mounting bracket (stem not included) XUZK2004
M12 Stem (75 mm usable length) XUZ2001

XUZC50 XUZA51 3-D mounting base XUZ2003


See page 159 for complete 3-D assembly.

Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory

1
2

20 28
0,4 1,2 5,7
4

20 0,8m 4

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

51
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUK Sub-compact Rectangular
DC and AC/DC
XUK Subcompact Rectangular / DC and AC/DC

Features:
805167

• Universal mounting and popular 50mmx50mm housing size


• Optimum version low cost perfect for use by OEMs
• Hinged plastic cover locks and provides protection to adjustments
Operating
Circuit Voltage Connection Load Current
XUK•AL•••2
Photoelectric Sensors

Output Mode Frequency Catalog Number


Type Range Type a Maximum
Maximum
Thru-Beam (receiver) 30 m (98’) Nominal Sensing Distance (emitter sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK2APANL2R
N.C. PNP 12-240 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK2APBNL2R
805166

N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK2ANANL2R


N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK2ANBNL2R
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK2APANM12R
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK2APBNM12R
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK2ANANM12R
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK2ANBNM12R
Thru-beam (receiver) 20 m (66’) Nominal Sensing Distance (emitter sold separately)
XUK•A•••M12
N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK2ARCNL2R
Thru-Beam (emitter)
– – 12-24 Vdc 2 m (6.6’) cable – – XUK2AKSNL2T
Dimensions – – 12-24 Vdc 4 pin micro conn – – XUK2AKSNM12T
– – 20-240 Vac/dc 2 m (6.6’) cable – – XUK2ARCNL2T

1.9 Retroreflective 9 m (30’) Nominal Sensing Distance (reflectors sold separately)


50 1.57 Ø 4,5 0.7 N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK1APANL2
40 18
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK1APBNL2
0.8

N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK1ANANL2


20 1.9 20
1.57

N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK1ANBNL2


40

50

N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1APANM12
0.8

N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1ANBNM12
Retroreflective 7 m (22’) Nominal Sensing Distance (reflectors sold separately)
Dual Dimensions inches N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK1ARCNL2
mm
Polarized Retroreflective 5 m (16’) Nominal Sensing Distance (reflectors sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9ANBNL2
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9APANM12
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9ANBNM12
Polarized Retroreflective 4 m (13’) Nominal Sensing Distance (reflectors sold separately)
N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK9ARCNL2
Proximity Diffuse 1 m (3.3’) Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5ANBNL2
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5APANM12
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5ANBNM12
Proximity Diffuse 1 m (3.3’) Nominal Sensing Distance
N.C. / N.O. AC/DC relay 20-340Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK5ARCNL2
a 10 m cable length available with L10 suffix

Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.

52
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUK Sub-compact Rectangular
DC and AC/DC
XUK Subcompact Rectangular / DC and AC/DC

Specifications
Wiring Mechanical
For usable sensing range, see detecton curves
Connector M12
4 3 Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 2 NEMA Type 4, 4X (indoor), 12, 13
Enclosure Rating
IEC Type IP65
Cable PNP/NPN PNP

Photoelectric Sensors
Case PBT
BN/1 +
(-) Blue PNP BK/4 (NO/NC) Enclosure Material Lens PMMA
(+) Brown Cable PVR
(Output) Black BU/3 –
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
NPN Emitter Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
BN/1 + Output Yellow
1/BN
NPN
BK/4 (NO/NC) 2/VI LED indicator Stability Red
3/BU
BU/3 – Power Green (XUK2…T)
Cable 4.2 mm O.D. 3 conductor
Cable Connection
Connector (DC version) 4 pin Micro style DC (M12)
Common White
Blue N.O. Black Electrical AC/DC DC
Brown N.C. Gray Voltage Range 20-240 Vac/dc 12 – 24 Vdc
Emitter Voltage Limit (including ripple) 20-264 Vac/dc 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V 1.5 V
Current Consumption (no load) maximum 2W 35 mA
Load Current maximum 3A 100 mA
Maximum Operating Frequency 20 Hz 250 Hz
On Delay Maximum 25 ms 2 ms
550028

550029

Off Delay Maximum 25 ms 2 ms


Power up Delay Maximum 60 ms 15 ms
Overload Protection Yes Yes
Protective Circuitry Reverse Polarity Protection – Yes
Short Circuit Protection – Yes

XUZK2003 XUZK2004 Agency Listings


®

Accessories
550030
805799

Description Catalog Number


Reflector 50x50 mm XUZC50
90 ° metal mounting bracket XUZA51
3-D mounting bracket (stem not included) XUZK2003
3-D protective mounting bracket (stem not included) XUZK2004
M12 Stem (75 mm usable length) XUZ2001
XUZC50 XUZA51 3-D mounting base XUZ2003
See page 159 for complete 3-D assembly.

Detection Curves
Thru-Beam System Polarized Retroreflective Retroreflective Systems Diffuse System

(1) Relay Output


(2) PNP/NPN
(1) Relay Output (1) Relay Output 0,8
(2) PNP/NPN (2) PNP/NPN

0,5 1,5

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

53
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
XUX Compact Rectangular
Multi-Mode, DC and AC/DC
XUX Compact Rectangular / Multi-Mode, DC and AC/DC
520220

Features:
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
• Housing: Plastic
Photoelectric Sensors

XUX 0ARTT16 • N.C. / N.O. selectable


520221

Operating
Circuit Voltage Load Current
Output Mode Connection Type Frequency Catalog Number
Type Range Maximum
Maximum
N.C. / N.O. PNP/NPN 12-24 Vdc PG 16 cable gland 100 mA 250 Hz XUX0AKSAT16
N.C. / N.O. PNP/NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX0AKSAM12
N.C. / N.O. AC/DC relay 20-240 Vac/dc PG 16 cable gland 3A 25 Hz XUX0ARCTT16

Accessories
XUX 0AKSAM12 Description Connection Type Catalog Number
Reflector – XUZC50
12-240 Vdc 2 m (6.6’) cable XUX0AKSAT16T
Transmitter 12-240 Vdc 4 pin micro conn. XUX0AKSAM12T
24-240 Vac/dc 2 m (6.6’) cable XUX0ARCTT16T
Dimensions a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
PG 16 cable gland is for cable size from 0.27" to 0.40" (7 to 10 mm) diamter.
(1)
4.09 (104)
4.48 (114)
3.62 (92)
2.9

(3)
73

(2)
Excess Gain
1.18
M12
30
1.49
38
0.82 (21) An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
1.96 1.20 (30.5)
50
modes.
2.8
71 3.0
77
Variation of Usable Sensing Distance
3.4
87 Diffuse System with Adjustable Background Suppression
Learning at Minimum Learning at Maximum
XUX•••••M12
B B
A-B: Object Reflection Coefficient
(1) Black 6%
4.09 (104)
3.62 (92)

Gray 18%
5.0 (127)
3.4
87

(3)
White 90%
Sensing Range
A 0,07 Non-sensing Zone (matt surfaces)
0,4 0,5 S (m) A 0,01 1,3 1,5 S (m)
(2) 1.18 0,42 1,35
0.86 (22)
30
1.49 1.18 (30)
38
1.96
50
2.8
71 3.0 XUZX2001 XUZX2002
3.44 77
1.2 1.2
87.5
31 31
0.43 0.43
11
XUX•••••T16 11
M16 x 1.5
M20 x 1.5

M16 x 1.5

1/2" NPT

inches (mm) /

Dual Dimensions inches


mm

54
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
XUX Compact Rectangular
Multi-Mode, DC and AC/DC
XUX Compact Rectangular / Multi-Mode, DC and AC/DC

Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 Diffuse Background Supp. 1.3 m
Sensing Distance (Sn) Diffuse Standard 2m
1 2
(excess gain = 2) Pol. Retroreflective 11 m
Thru-beam 40 m
PNP/NPN Emitter

Photoelectric Sensors
M12 Terminal M12 Terminal Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
1 • 1 + 1 • 1 + Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
3 • 2 – 3 • 2 –
NEMA Type 4, 4X (indoor), 12, 13
4 • 3 2 • 3 Enclosure Rating
– • 4 — IEC Type IP67
– • 5 — Case PBT
Output Emitter Enclosure Material Lens PMMA
Terminal Terminal Cable PVR
1 1
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
2 2
3 N.O. Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
4 Output Yellow
5 N.C.
LED indicator Signal Instability Red
Power & Teach Green
Cable Gland M16
Connection
Connector (DC version) 4 pin Micro style DC (M12)
Electrical AC/DC DC
Voltage Range 24-240 Vac/dc 12-24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10-36 Vdc
550041

Voltage Drop (across switch) closed state maximum 1.5 V 1.5 V


Current Consumption (no load) maximum 2W 35 mA (20 mA – Transmitter)
Alarm Output 100 mA
550040

Load Current maximum 3A 100 mA


Maximum Operating Frequency 20 Hz 240 Hz
On Delay Maximum 25 ms 2 ms
Off Delay Maximum 25 ms 2 ms
Power up Delay Maximum 200 ms 200 ms
XUZX2003 XUZX2004 Overload Protection Yes Yes
Protective Circuitry Reverse Polarity Protection – Yes
Short Circuit Protection – Yes
E164869
Agency Listings CCN NRKH
805799

Accessories
Description Catalog Number
Reflector 50x50 mm XUZC50
3-D mounting bracket (stem not included) XUZX2003
XUZC50 XUZX2001 3-D protective mounting bracket XUZX2004
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Adapter ISO 16 to 1/2" NPT XUZX2001
Adapter ISO 16 to ISO 20 XUZX2002
See page 159 for complete 3-D assembly.

Detection Curves
80 Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
40 with Background Suppression Accessory
20 Ø 8 mm
2 15
20 40 60 10
-20
1
-40
-80 11 15m
40 1 2 3 0,2
1,5
1
2,6
-10
2 -15
Sn < 2 Sn 11 m

Object: 3.9 x 3.9" (10 x 10 cm)


With Reflector XUZC50
1: White 90%, 2: Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

55
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUX Compact Rectangular
DC and AC/DC
XUX Compact Rectangular / DC and AC/DC

Features:
• Interchangeable mounting of competitive compact sensor body styles.
• Available with terminal block wiring or connector version.
Operating
Voltage Connection Load Current
Output Mode Circuit Type Frequency Catalog Number
Range Type Maximum
Maximum
Photoelectric Sensors

Thru-Beam (receiver)40–m (130‘) Nominal Sensing Distance (emitter sold separately)


XUX•A••NT16 N.O. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX2APANT16R
N.C. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX2APBNT16R
N.O. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX2ANANT16R
N.C. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX2ANBNT16R
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX2APANM12R
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX2APBNM12R
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX2ANANM12R
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX2ANBNM12R
N.O. AC/DC relay 20-240Vac/dc PG16 cable entry 3A 20Hz XUX2ARCNT16R
Thru-Beam (emitter)
– – 12-24 Vdc PG16 cable entry – – XUX2AKSNT16T
– – 12-24 Vdc 4 pin micro conn. – – XUX2AKSNM12T
– – 20-240 Vac/dc PG16 cable entry – – XUX2ARCNT16T
XUX•A••M12 Retroreflective 14m (45‘) Nominal Sensing Distance (reflectors sold separately)
N.O. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX1APANT16
N.C. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX1APBNT16
N.O. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX1ANANT16
N.C. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX1ANBNT16
Dimensions N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX1APANM12
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX1APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX1ANANM12
(1)
4.05 (103)

N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX1ANBNM12
4.44 (113)
3.62 (92)
2.9

(3)
73

N.C.N.C. / N.O. AC/DC relay 20-240 Vac/dc PG16 cable entry 3A 20 Hz XUX1ARCNT16
Polarized Retroreflective 11m (36‘) Nominal Sensing Distance (reflectors sold separately)
(2) 1.18 N.O. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9APANT16
M12
30 N.C. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9APBNT16
1.45 0.82 (21)
37 N.O. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9ANANT16
1.96 1.20 (30.5)
50 N.C. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9ANBNT16
2.8
71 3.0 N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9APANM12
77 N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9APBNM12
3.4
87 N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9ANBNM12
XUX•••••M12 N.C. / N.O. AC/DC relay 20-240 Vac/dc PG16 cable entry 3A 20 Hz XUX9ARCNT16
Proximity Diffuse 2.1m (7.9‘) Nominal Sensing Distance
N.O. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5APANT16
(1)
4.09 (104)
3.62 (92)

N.C. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5APBNT16
5.0 (127)
3.4
87

(3)
N.O. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5ANANT16
N.C. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5ANBNT16
(2) 1.18 N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5APANM12
0.86 (22)
30
1.49 1.2 (30.5) N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5APBNM12
38 N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5ANANM12
1.96
50 N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5ANBNM12
2.8
71 3.0
N.C. / N.O. AC/DC relay 20-240 Vac/dc PG16 cable entry 3A 20 Hz XUX5ARCNT16
3.44 77 PG 16 cable gland is for cable size from 0.27" to 0.40" (7 to 10 mm) diamter.
87.5

XUX•••••T16
Excess Gain
inches (mm) /

An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing modes.
Dual Dimensions inches
mm
XUZX2001 XUZX2002
1.2 1.2
31 31
0.43 0.43
11 11
M16 x 1.5
M20 x 1.5

M16 x 1.5

1/2" NPT

56
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUX Compact Rectangular
DC and AC/DC
XUX Compact Rectangular / DC and AC/DC

Wiring Specifications
Mechanical
Connector M12
For usable sensing range, see detection curves
4 3
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 2
NEMA Type 1, 3, 4, 13
PNP/NPN Emitter Enclosure Rating
IEC Type IP67
M12 Terminal M12 Terminal

Photoelectric Sensors
1 • 1 + 1 • 1 + Case PBT
3 • 2 – 3 • 2 – Enclosure Material Lens PMMA
4 • 3 2 • 3
Cable PVR
– • 4 — – • 4 —
– • 5 — – • 5 — Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30g, duration 11ms
Output Emitter
Terminal Terminal Output Yellow
1 1 LED indicator
Power Green
2 2
3 N.O. 3 — Cable gland M16
Connection
4 4 — Connector (DC version) 4 pin Micro style DC (M12)
5 N.C. 5 —
Electrical AC/DC DC
Voltage Range 20-240 Vac/dc 12-24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10-36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V 1.5 V
Current Consumption (no load) maximum 2W 35 mA
Load Current maximum 3A 100 mA
550041

Maximum Operating Frequency 20 Hz 250 Hz


On Delay Maximum 25 ms 2 ms
Off Delay Maximum 25 ms 2 ms
550040

Power up Delay Maximum 60 ms 15 ms


Overload Protection Yes Yes
Protective Circuitry Reverse Polarity Protection – Yes
Short Circuit Protection – Yes
E164869
XUZX2003 Agency Listings CCN NRKH
XUZX2004 ®

Accessories
805799

Description Catalog Number


Reflector 50x50 mm XUZC50
3-D mounting bracket (stem not included) XUZX2003
3-D Protective mounting bracket (stem not included) XUZX2004
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
XUZC50 XUZX2001
Adapter ISO 16 to 1/2" NPT XUZX2001
Adapter ISO 16 to ISO 20 XUZX2002
See page 159 for complete 3-D assembly.

Detection Curves
Thru-Beam System Diffuse System Polarized Retroreflective Retroreflective System

80 6 15 15
40 4 10 10
20 Ø 8 mm 2 5 5

20 40 60 0,7 2,10 3 10 15 m
-2 13 20 m
-20 -5 5 8
-4 -5
-40
-6 -10 -10
-80
40 Sn 2,1m -15 Sn 11 m -15 Sn 14 m

Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %,


With reflector XUZ C50
2 : Gray 18 %

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

57
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Self-Teach XUD Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
Self-Teach XUD Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics

Features:
550026

XUDA1
• Self-teach capability
• Selectable light(N.C.)/dark(N.O.)
• Nano style connector available
Photoelectric Sensors

• Fast response time


XUD A1 • Short circuit protection
• Reverse polarity protection
-

XUDA2
+

• Digital display for adjustment


• Self-teach capability (and fine adjustment)
• On/Off time delay
• Nano style connector available
• Higher Frequency selectable
XUD A2
• Short circuit protection
• Reverse polarity protection
Circuit Voltage Load Current Operating
Output Mode Catalog Number
Type Range Maximum Frequency
Dimensions XUDA1 – Amplifiers
2 m (6.6’) cable
XUD A•
PNP N.C. / N.O. 12-24 Vdc 100 mA 1000 Hz XUDA1PSML2
NPN N.C. / N.O. 12-24 Vdc 100 mA 1000 Hz XUDA1NSML2
M8 Nano connector
1.57

PNP N.C. / N.O. 12-24 Vdc 100 mA 1000 Hz XUDA1PSMM8


40

NPN N.C. / N.O. 12-24 Vdc 100 mA 1000 Hz XUDA1NSMM8


XUDA2 – Amplifiers
2.5 0.4
65 10 2 m (6.6’) cable
PNP N.C. / N.O. 12-24 Vdc 100 mA 1000 Hz or 5000 Hz XUDA2PSML2
XUD A1
NPN N.C. / N.O. 12-24 Vdc 100 mA 1000 Hz or 5000 Hz XUDA2NSML2

SET
ALM OUT M8 Nano connector
PNP N.C. / N.O. 12-24 Vdc 100 mA 1000Hz or 5000Hz XUDA2PSMM8
XUD A2 NPN N.C. / N.O. 12-24 Vdc 100 mA 1000Hz or 5000Hz XUDA2NSMM8
For XUFN and XUFS fiber optics see page 120 - 123.
OUT

- SET + H T S

Dual Dimensions inches


mm

58
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Self-Teach XUD Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
Self-Teach XUD Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics

Specifications
Wiring Mechanical
Temperature Range 13 ° F to 131 ° F (-10 ° C to 55 ° C)
XUDA1
No. Sensing Distance (Sn) Dependent on fiber optic (page 120)
Connector NEMA Type 1, 3, 4, 6, 12, 13
1 (+)
2 4 3 (-) Enclosure Rating
IEC Type IP65
4 Output
1 3
2 Vibration 7 g, amplitude +/-0.5 mm (f=10 to 55 Hz)

Photoelectric Sensors
Shock resistance 30 g, duration 11ms
Cable Output Yellow
LED Indicator
Signal Instability XUDA1 Red / XUDA2 Green
(+) Brown
(-) Blue Signal Level Display XUDA1– 7 LED segment / XUDA2 – 4 digit display
Output Black Cable version 4.2 mm O.D. 4 conductor
Connection
PNP NPN Connector version 4 pin M8 nano connector
BN/1 + BN/1 + Electrical
PNP NPN
BK/4 BK/4 Voltage Range 12-24 Vdc
BU/3 – BU/3 – Voltage Limit (including ripple) 10-30 Vdc
Maximum Load Current 100 mA
Current Consumption (no load) 50 mA
Alarm output current 50 mA (XUDA2)
Voltage Drop across Switch 1V
XUDA2
On Delay XUDA1 – 0.5 ms / XUDA2 – 0.1 ms
Connector
1 (+) Off Delay XUDA1 – 0.5 ms / XUDA2 – 0.1 ms
2 4 3 (-) Power up Delay 120 ms
4 Output
1 3
2 Alarm Short Circuit Protection Yes
Overload Protection Yes
Cable Reverse Polarity Protection Yes

(+) Brown Agency Listings


(-) Blue ®

Output Black
Alarm White

PNP NPN
BN/1 + BN/1 +
PNP NPN
BK/4 WH/2 BK/4 WH/2

BU/3 – BU/3 –

Connector Cables (M8 or S suffix)


XSZCS141 Nano conn., 4 pin, 2m, straight
XSZCS151 Nano conn., 4 pin, 2m 90 °
For additional cable options and lengths see p. 518

59
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUA 8 mm Diameter
Miniature Precision, DC
XUA 8 mm Diameter / Miniature Precision, DC

Features
• Ultra short miniature body
• Very fast response time
• Rugged metal case
• Short circuit, overload, and reverse polarity protection
Photoelectric Sensors

thread
• CE Mark
M8x1
Load Operating
Circuit Output Voltage
Current Frequency Catalog Number
Type Mode Range
Dimensions Max. Max.
Thru-beam (Emitter – Receiver) – 6.6' (2m) Nominal Sensing Range a
DC – 6' (2m) cable
.16
4 Emitter 2 wire – 12-24 V – – XUAH0203
Receiver 3 wire, PNP N.C. 12-24 V 100 mA 2000 Hz XUAH0224
Receiver 3 wire, PNP N.O. 12-24 V 100 mA 2000 Hz XUAH0214
1.18 Receiver 3 wire, NPN N.C. 12-24 V 100 mA 2000 Hz XUAJ0224
1.57 30
Receiver 3 wire, NPN N.O. 12-24 V 100 mA 2000 Hz XUAJ0214
40 M8x1
DC – Nano style connector (8 mm)➁
Emitter 2 wire – 12-24 V – – XUAH0203S
Receiver 3 wire, PNP N.C 12-24 V 100 mA 2000 Hz XUAH0224S
Receiver 3 wire, PNP N.O. 12-24 V 100 mA 2000 Hz XUAH0214S
Receiver 3 wire, NPN N.C 12-24 V 100 mA 2000 Hz XUAJ0224S
Receiver 3 wire, NPN N.O. 12-24 V 100 mA 2000 Hz XUAJ0214S
Proximity (Diffuse) – 1.9" (5cm) Nominal Sensing Range a ➀
LED
DC – 6' (2m) cable
.14 3 wire, PNP N.O. 12-24 V 100 mA 700 Hz XUAH0515
3.5
3 wire, PNP N.C. 12-24 V 100 mA 700 Hz XUAH0525
3 wire, NPN N.O. 12-24 V 100 mA 700 Hz XUAJ0515
3 wire, NPN N.C. 12-24 V 100 mA 700 Hz XUAJ0525
DC – Nano style connector (8 mm)➁
Nano Style Connector 3 wire, PNP N.O. 12-24 V 100 mA 700 Hz XUAH0515S
3 wire, PNP N.C. 12-24 V 100 mA 700 Hz XUAH0525S

.16 3 wire, NPN N.O. 12-24 V 100 mA 700 Hz XUAJ0515S


4 3 wire, NPN N.C. 12-24 V 100 mA 700 Hz XUAJ0525S
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ With 90% Kodak White paper. 2 in x 2 in (5 cm x 5 cm)
1.02 ➁ See p. 518 for Nano connector cables.
26
1.81
46 M8x1 Excess gain curves (ambient temperature: +25° C) Variation of sensing distance Sn
Thru-beam system Diffuse system Diffuse system

Gain Gain (%) Sensing distance


500 100
LED * 40
300 80
100 20
50 15 60
10
9 40
10 20
5 3
0
0 2 4 6 8 10 12 14 16
1 1
C: Side of square object C (cm)
* One LED, visible from 4 quadrants 0.1 0.2 0.5 1 2 4 6 10
D (cm)
0.1 0.2 0.4 0.8 2 8 10
0.3 0.8 5 0.6 1 4 6 9
D (cm) White 90% Gray 18%
Object 5 x 5 cm
White 90%
Detection differential (H) when the object approaches
from the front at the nominal distance: H≤ 25% of Sn

13

Dual Dimensions inches


mm

60
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUA 8 mm Diameter
Miniature Precision, DC
XUA 8 mm Diameter / Miniature Precision, DC

Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
Sensor side Temperature range -13° F to +131° F (-25° C to +55° C)
(OUT) NEMA Type 4, 6, 6P, 12, 13
thru-beam
4 (TEST) emitter only
Enclosure rating
CENELEC Type
IP67 conforming to IEC60529 (IP673 conforming to NF C 20-
010)
Mounting torque 1.47 ft-lb (2 N•m), Connector tighten torque
Tightening torque (max.)
0.14 ft-lb (0.3 N•m)

Photoelectric Sensors
(+) 1 3 (–)
Vibration 7 g, amplitude +/- .75 mm (f=10 to 55 Hz)
Shock resistance 30 g, duration 11 ms, conforming to IEC 60068-2-27
Case Nickel plated brass
Emitter Enclosure material
Lens PMMA
BN +
Wiring Cable: PVC, diameter 3.5 mm, wire AWG 26,3 x 0.14 mm2
BU - Electrical
VI Test Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 30 Vdc
Voltage drop (across switch), closed state (max.) 1.8 V
PNP output
Maximum load current 100 mA
BN 1+
Current consumption (no load) (max.) Emitter: 20 mA; receiver: 20 mA; diffuse: 25 mA
BK 4
Maximum operating frequency Thru-beam: 2000 Hz, Proximity (Diffuse) 700 Hz
BU 3-
On delay (max.) Thru-beam: 0.25 ms Proximity (Diffuse): 0.75 ms
Off delay (max.) Thru-beam: 0.25 ms Proximity (Diffuse): 0.75 ms
NPN output Power-up delay (max.) 20 ms
BN 1+ Physical Characteristics
BK 4 Ambient light immunity 3000 Lux
BU 3- Thru-beam 890 nm
Emitter wave length:
Proximity (Diffuse) 940 nm
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V per meter)
Fast transients (motor start/stop
IEC 61000-4-4, L3 (1 kV)
interference)
Impulse voltages (lightning, etc.) IEC 60947-5-2, L3 (2.5 kV)
E164869
Agency Listings CCN NRKH
®

a L indicates level number

XSZB108 831608
Accessories
Description Catalog Number
Universal mounting bracket (Plastic) XSZB108
Mounting bracket, diecast zinc 831608
Mounting bracket, plastic XSAZ108
Metal mounting nuts XSZE108

Sensing Pattern
Thru-beam System Diffuse System

Diameter of Beam Diameter of Beam


cm T/R cm
XSZE108 XSAZ108
6 1 2 1
4 0.5
.5 mm
T 2 R
5 cm
-0.5
-2 2 3 m -1
-4
Sn 0.5m
-6 Sn 2 m
Object 5 x 5 cm
Connector Cables (M8 or S suffix) 1 White 90% 2 Gray 18%
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories. . . . . . . . . . . . . . . . . . . . . . . .page 157

61
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - Front Sensing, DC

thread
Features
M18x1 • Housing: Plastic
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
• Sensing modes: Thru-beam (emitter and receiver packaged together), Retroreflective,
Photoelectric Sensors

Polarized Retroreflective (XUZC50 reflector included in Retroreflective models),


Proximity Diffuse
• 2 meter cable standard
Dimensions
• Connector versions available
0.16
4.0 M18x1 LED • Wide selection of mounting brackets available
• Self locking mounting nuts included
• UL Listed, CSA Certified
0.2in. Dia. • CE marked
1.97 5mm Dia.
50 Operating
2.44 Output Circuit Voltage Load Current Catalog
Connection Type Frequency
62 Mode Type Range Maximum Number
Maximum
XUkP18kk340
Thru-Beam System (Emitter-Receiver) –15 m (48') Nominal Sensing Rangea
Light/Dark PNP 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU2P18PP340
0.16 Light/Dark PNP 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU2P18PP340D
M18x1 LED
4.0 Light/Dark NPN 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU2P18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU2P18NP340D
Retroreflective –4 m (13') Nominal Sensing Rangea (XUZC50 reflector included)
Light/Dark PNP 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU1P18PP340
Light/Dark PNP 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU1P18PP340D
1.97
Light/Dark NPN 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU1P18NP340
50 2.44
Light/Dark NPN 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU1P18NP340D
2.83 62
Polarized Retroreflective –1.5 m (4.9') Nominal Sensing Range (XUZC50 reflector included)
72
Light/Dark PNP 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU9P18PP340
XUkP18kk340D
Light/Dark PNP 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU9P18PP340D
Light/Dark NPN 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU9P18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU9P18NP340D
Proximity Diffuse –10 cm (4") Nominal Sensing Rangea
Light/Dark PNP 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU5P18PP340
Light/Dark PNP 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU5P18PP340D
.91 Dual Dimensions inches
mm Light/Dark NPN 12 to 24 V 2 m (6.6’) Cable 100 mA 500 Hz XU5P18NP340
24
Light/Dark NPN 12 to 24 V 4 pin Micro Connector c 100 mA 500 Hz XU5P18NP340D
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables.

Excess Gain Curves (ambient temperature: +25° C)


Thru-beam Retroreflective Polarized Retroreflective Diffuse
gain gain gain gain
100 100 10
80
50 50
20
30 30
20 10 20
15
10 1 10
8 7
5 1 5
3 3
2 2

1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%

62
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - Front Sensing, DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
1 (+)
Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 4 Storage -40° to 158° F (-40° to 70° C)
Program- Output NEMA Type 4X (Indoor), 12
ming 3 (-)
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Case PPS

Photoelectric Sensors
Light operate (no object present) Enclosure Material Lens PMMA
Retroreflective - PNP output Cable PvR
OG Mounting Nuts 5 N•m (44.4 lb-in)
Maximum Tightening Torque
BN Connector 2 N•m (17.7 lb-in)
BK Vibration Resistance (IEC 60068-2-6) 25 gn, amplitude ± 2mm (f = 10 Hz to 55 Hz)
BU
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
Diffuse - PNP output
LED Indicator Type 360° ring LED: shows output status
OG
BN Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
Connection
Connector 4 pin Micro style DC (M12 male)
BK
BU Electrical
Retroreflective - NPN output Voltage Range 12 – 24 Vdc
OG
Voltage Limit (Including Ripple) 10 – 30 Vdc
BN
BK Voltage Drop (Across Switch) Closed State Maximum 1.5 V
BU Current Consumption (No Load) Maximum 30 mA Reflex and Diffuse, 50 mA Thru-Beam
Diffuse - NPN output Load Current Maximum 100 mA
OG
BN
Maximum Operating Frequency 500 Hz
BK On Delay Maximum 1 ms
BU Off Delay Maximum 1 ms
Dark operate (no object present) Power-up Delay Maximum 15 ms
Retroreflective - PNP output Short Circuit Protection Yes
BN
Overload Protection Yes
BK
BU Reverse Polarity Protection Yes
OG E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
Diffuse - PNP output ®

BN
BK Accessories
BU
Description Catalog Number
OG
Swivel Ball Mounting Bracket XUZA218
Retroreflective - NPN output
Plastic Mounting Bracket XSZB118
BN
Metal 90° Mounting Bracket 9006PA18
BK
Zinc Diecast 90° Mounting Bracket XUZA118
BU
OG Plastic Mounting Nuts XSZE218
Stainless Steel Mounting Nuts XSZE318
Diffuse - NPN output
BN
BK
BU
OG
Detection Curves

Thru-beam Retroreflective Polarized Retroreflective Diffuse

Dia. of beam Dia. of beam Dia. of beam Dia. of beam


cm cm cm cm
10 6 1.4
T/R
15 4 1
O 12 mm T/R 4 E/R 2 2 1
E R

m 4 m 1.5 2 m
10 15 -4 2 -2 0.2 10 cm
-15 -10 -4 -1
-6 -1.4
Sn 4 m Sn 1.5 m Sn 0.10 m
Sn 15 m

With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm


1 White 90%
2 Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . . . page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . . page 156

63
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - 90 Degree Side Sensing, DC

Features
thread
M18x1 • Housing: Plastic
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
Photoelectric Sensors

• Sensing modes: Thru-beam (emitter and receiver packaged together), Retroreflective,


(XUZC50 reflector included). Also available in front sensing style
• 2 meter cable standard
• Connector versions available
Dimensions
• Wide selection of mounting brackets available
0.16
4 M18x1 LED • Self locking mounting nuts included
• UL Listed, CSA Certified
• CE marked
5 Output Circuit Load Current Operating Frequency Catalog
Voltage Range Connection Type
1.97 Mode Type Max. Max. Number
50 3.07 Thru-Beam System (Emitter - Receiver) - 15 m (48’) Nominal Sensing Range a
78 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2P18PP340W
XUkP18kk340W Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2P18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2P18NP340W
0.16 Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2P18NP340WD
4 M18x1 LED
Retroreflective - 4 m (13’) Nominal Sensing Range (XUZC50 reflector included)a
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU1P18PP340W
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU1P18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU1P18NP340W
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU1P18NP340WD
1.97
50 Polarized Retroreflective - 1.5 m (4.9’) Nominal Sensing Range (XUZC50 reflector included)a
2.44
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9P18PP340W
3.46 62
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9P18PP340WD
87
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9P18NP340W
XUkP18kk340WD
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9P18NP340WD
Proximity Diffuse - 10 cm (4") Nominal Sensing Range
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5P18PP340W
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5P18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5P18NP340W
.94 Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5P18NP340WD
Dual Dimensions inches
24 mm
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables.

Excess Gain Curves (ambient temperature: +25° C)


Thru-beam Retroreflective Polarized Retroreflective Diffuse
gain gain gain gain
100 100 10
80
50 50
20
30 30
20 10 20
15
10 1 10
8 7
5 1 5
3 3
2 2

1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%

64
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - 90 Degree Side Sensing, DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Thru-beam
emitter only All others Operation -13° to 131° F (-25° to 55° C)
1 (+) 1 (+)
Temperature Range
Storage -40° to 158° F (-40° to 70° C)
2 4 2 4 NEMA Type 4X (indoor), 12
Test Pro- Enclosure Rating
Output
3 (-) gramming 3 (-) CENELEC Type IP67 conforming to IEC 60529

Photoelectric Sensors
Vibration 7 G amplitude + 1.5 mm (f=10 to 55 Hz)
(-) BU (Blue)
(+) BN (Brown) Shock Resistance 30 gn for 11 ms conforming to 68-2-27
(OUT) BK (Black) LED Indicator Type 360° ring LED: shows output state
(Prog.) OG (Orange) Case PC/ABS
(Violet) Enclosure Material
(Test) VI Lens PMMA
For Thru-beam Emitter Only
Cable 4 wire, 4 x 0.34 mm2, PvR
Wiring
Light operate (no object present) Connector 4 pin Micro connector
Retroreflective
PNP output Electrical
OG
BN Voltage Range 12 – 24 Vdc
BK Voltage Limit (Including Ripple) 10 – 30 Vdc
BU Current Consumption (Maximum) (No Load) 30 mA Reflex and Diffuse, 50 mA Thru-Beam
NPN output Voltage Drop 1.5 V
OG
Power-up Delay (Maximum) 15 mA
BN
BK On Delay (Maximum) 1 ms
BU Off Delay (Maximum) 1 ms
Short Circuit Protection Yes
Diffuse Protective Circuitry
PNP output Overload Protection Yes
OG
BN E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
BK ®

BU

NPN output
OG
Detection Curves
BN
BK Thru-beam Retroreflective Polarized retroreflective Diffuse
BU
Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
10 6 1.4
T/R
Dark operate (no object present) 15 4 1
O 12 mm T/R 4 T/R 2 2 1
Retroreflective E R
PNP output 4 m 1.5 2 m
10 15 m -4 2 -2 0.2 10 cm
BN -15 -10 -4 -1
-6 -1.4
BK Sn 4 m Sn 1.5 m Sn 0.10 m
Sn 15 m
BU
OG With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
NPN output 1 White 90%
2 Grey 18%
BN
BK
Beam break test (for thru-beam emitter only)
BU Beam made Beam broken
OG BN/1 BN/1

Diffuse
PNP output VI/2 VI/2

BN
BK BU/3 BU/3
BU
OG
NPN output
BN
BK
BU
OG

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . .Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 156

65
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - Front Sensing, DC

thread Features
M18x1
• Housing: Nickel plated brass
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
Photoelectric Sensors

• Sensing modes: Thru-beam (emitter and receiver packaged together), Retroreflective,


Polarized Retroreflective (XUZC50 reflector included in Retroreflective models), Proximity
Diffuse
• Also available in side sensing style
Dimensions
• 2 meter cable standard
0.16 • Connector versions available
4.0 M18x1 LED
• Wide selection of mounting brackets available
• Self locking mounting nuts included
• UL Listed, CSA Certified
0.2in. Dia.
1.97 5mm Dia. • CE marked
50 2.44
62 Operating
Output Circuit Voltage Load Current Catalog
Connection Type Frequency
XUkN18kk340 Mode Type Range Maximum Number
Maximum
Thru-Beam System (Emitter-Receiver) –15 m (48') Nominal Sensing Rangea
0.16
M18x1 Light/Dark PNP 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU2N18PP340
LED
4.0 Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2N18PP340D
Light/Dark NPN 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU2N18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2N18NP340D
Retroreflective –4 m (13') Nominal Sensing Rangea (XUZ C50 Reflector Included)
Light/Dark PNP 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU1N18PP340
1.97
50 Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU1N18PP340D
2.44
Light/Dark NPN 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU1N18NP340
2.83 62
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU1N18NP340D
72
Polarized Retroreflective –1.5 m (4.9') Nominal Sensing Rangea (XUZ C50 Reflector Included)
XUkN18kk340D
Light/Dark PNP 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU9N18PP340
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9N18PP340D
Light/Dark NPN 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU9N18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9N18NP340D
Proximity Diffuse –10 cm (4") Nominal Sensing Rangea
Light/Dark PNP 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU5N18PP340
.91 Dual Dimensions inches Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5N18PP340D
24 mm
Light/Dark NPN 12 to 24 V 2 m (6.6’) cable 100 mA 500 Hz XU5N18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5N18NP340D
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables.

Excess Gain Curves (ambient temperature: +25° C)


Thru-beam Retroreflective Polarized Retroreflective Diffuse
gain gain gain gain
100 100 10
80
50 50
20
30 30
20 10 20
15
10 1 10
8 7
5 1 5
3 3
2 2

1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%

66
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - Front Sensing, DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
1 (+)
Operating -13° to 131° F (-25° to 55° C)
2 4 Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
Program- Output
ming NEMA Type 4X (Indoor), 12
3 (-) Enclosure Rating
IEC Type IP67 conforming to IEC 60529

Light operate (no object present) Case Nickel plated brass

Photoelectric Sensors
Enclosure Material Lens PMMA
Retroreflective - PNP output Cable PvR
OG Mounting Nuts 15 N•m (133.3 lb-in)
Maximum Tightening Torque
Connector 2 N•m (17.7 lb-in)
BN
Vibration Resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
BK
BU Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
LED Indicator Type 360° ring LED: shows output status
Diffuse - PNP output Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
OG Connection
Connector 4 pin Micro style DC (M12 male)
BN Electrical
BK Voltage Range 12 – 24 Vdc
BU Voltage Limit (Including Ripple) 10 – 30 Vdc
Retroreflective - NPN output Voltage Drop (Across Switch) Closed State Maximum 1.5 V
OG Current Consumption (No Load) Maximum 30 mA Reflex and Diffuse, 50 mA Thru-Beam
BN
Load Current Maximum 100 mA
BK
Maximum Operating Frequency 500 Hz
BU
On Delay Maximum 1 ms
Diffuse - NPN output Off Delay Maximum 1 ms
OG
Power-up Delay Maximum 15 ms
BN
Short Circuit Protection Yes
BK
Overload Protection Yes
BU
Reverse Polarity Protection Yes
Dark operate (no object present) E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
Retroreflective - PNP output ®

BN
Accessories
BK
Description Catalog Number
BU
Swivel Ball Mounting Bracket XUZA218
OG
Plastic Mounting Bracket XSZB118
Diffuse - PNP output Metal 90° Mounting Bracket 9006PA18
BN Zinc diecast 90° Mounting Bracket XUZA118
BK Plastic Mounting Nuts XSZE218
BU Stainless Steel Mounting Nuts XSZE318
OG
Detection Curves
Retroreflective - NPN output
Thru-beam Polarized Retroreflective Diffuse
BN Retroreflective
Dia. of beam Dia. of beam Dia. of beam Dia. of beam
BK cm cm cm cm
10 6 1.4
BU T/R
15 4 1
O 12 mm T/R 4 T/R 2 2 1
E R
OG
m 4 m 1.5 2 m
10 15 -4 2 -2 0.2 10 cm
Diffuse - NPN output -15 -4 -1
-10
-6 -1.4
BN Sn 4 m
Sn 15 m Sn 1.5 m Sn 0.10 m
BK
BU With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
OG 1 White 90%
2 Gre
y 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories. . . . . . . . . . . . . . . . . . . . . . . page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . . page 156

67
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - 90 Degree Side Sensing, DC

thread
Features
M18x1
• Housing: Nickel plated brass
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
Photoelectric Sensors

• Sensing modes: Retroreflective, Polarized Retroreflective (XUZC50 reflector included


in Retroreflective models)
• Proximity Diffuse
• Also available in front sensing style
Dimensions
• 2 meter cable standard
0.16
4.0 M18x1 LED • Connector versions available
• Wide selection of mounting brackets available
• Self locking mounting nuts included
0.2in. Dia. • UL Listed, CSA Certified
1.97 5mm Dia. • CE mark
50 3.03
77 Operating
Output Circuit Connection Load Current Catalog
XU●N18●●340W Voltage Range Frequency
Mode Type Type Max. Number
Max.

0.16 Thru-Beam System (Emitter - Receiver) - 15 m (48’) Nominal Sensing Range a


4.0 M18x1 LED Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2N18PP340W
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2N18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2N18NP340W
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2N18NP340WD
Retroreflective - 4 m (13’) Nominal Sensing Range (XUZC50 reflector included)a
1.97 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU1N18PP340W
50 2.44 Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU1N18PP340WD
3.42 62 Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU1N18NP340W
87 Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU1N18NP340WD
XU●N18●●340WD Polarized Retroreflective - 1.5 m (4.9’) Nominal Sensing Range (XUZC50 reflector included)a
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9N18PP340W
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9N18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9N18NP340W
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9N18NP340WD
Proximity Diffuse - 10 cm (4") Nominal Sensing Range
.91
Dual Dimensions inches Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5N18PP340W
24 mm
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5N18PNP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5N18NP340W
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5N18NP340WD
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables.

Excess Gain Curves (ambient temperature: +25° C)


Thru-beam Retroreflective Polarized Retroreflective Diffuse
gain gain gain gain
100 100 10
80
50 50
20
30 30
20 10 20
15
10 1 10
8 7
5 1 5
3 3
2 2

1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%

68
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - 90 Degree Side Sensing, DC

Wiring Specifications
Mechanical
Connector For usable sensors range, see excess gain curve charts
1 (+)
Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 4 Storage - 40° to 158° F (- 40° to 70° C)
Program- Output NEMA Type 4X (Indoor), 12
ming Enclosure Rating
3 (-) IEC Type IP67 conforming to IEC 60529
Case Nickel plated brass
Enclosure Material Lens PMMA

Photoelectric Sensors
Light operate (no object present)
Cable PvR
Retroreflective - PNP output Max. Tightening torque
Mounting nuts 15 N•m (133.3 lb-in)
OG Connector 2 N•m (17.7 lb-in)
BN Vibration resistance (IEC600 68-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BK
LED indicator type 360° ring LED: shows output status
BU
Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
Connection
Connector 4 pin Micro style DC (M12 male)
Diffuse - PNP output
OG
Electrical
Voltage Range 12 – 24 Vdc
BN
Voltage Limit (including ripple) 10 – 30 Vdc
BK
Voltage Drop (across switch) closed state max. 1.5 V
BU Current Consumption (no load) Max. 30 mA Reflex and Diffuse, 50 mA Thru-Beam
Retroreflective - NPN output Load Current Max. 100 mA
OG Max. Operating frequency 500 Hz
BN On delay max. 1 ms
BK Off delay max 1 ms
BU Power-up delay max 15 ms
Short circuit protection Yes
Diffuse - NPN output Overload protection Yes
OG
Reverse polarity protection Yes
BN E 164869 LR 44087
BK Agency Listings CCN NRKH Class 3211 03
®

BU
Accessories
Dark operate (no object present)
Description Catalog Number
Retroreflective - PNP output Swivel ball mounting bracket XUZA218
BN Plastic mounting bracket XSZB118
BK Metal 90° Mounting bracket 9006PA18
BU Zinc diecast 90° Mounting bracket XUZA118
OG Plastic mounting nuts XSZE218
Stainless Steel mounting nuts XSZE318
Diffuse - PNP output
BN
Detection Curves
BK Retroreflective Polarized retroreflective Diffuse
BU
OG
Dia. of beam Dia. of beam Dia. of beam
cm cm cm
Retroreflective - NPN output
10 6 1.4
BN T/R
4 1
BK T/R 4 T/R 2 2 1
BU 4 m
-4 1.5 2 m 10 cm
OG 2 -2 0.2
-10 -4 -1
Diffuse - NPN output -6 -1.4
BN Sn 4 m Sn 1.5 m Sn 0.10 m
BK
BU With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
OG
1 White 90%
2 Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

69
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic - Front Sensing, DC

thread Features
M18x1 • Housing: Plastic • Sensing modes: Thru-beam (emitter and receiver
• Modulated LED output indication packaged together), Retroreflective, Polarized
Retroreflective (XUZC50 reflector included in
• Short circuit (SCP) reverse polarity and
Retroreflective models), Proximity Diffuse,
overload protection
Proximity Diffuse with Background Suppression
• Light/Dark selectable
• Connector versions available
Photoelectric Sensors

• 2 meter cable standard


• Self locking mounting nuts included
• Wide selection of mounting brackets
• UL Listed, CSA Certified, CE Mark
Dimensions available
M18x1 Output Circuit Connection Load Current Operating Frequency Catalog
Voltage Range
Potentiometer Mode Type Type Max. Max. Number
0.16
LED Thru-Beam System (Emitter - Receiver) - 15 m (48’) Nominal Sensing Range a
4.0
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2B18PP340
Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU2B18PP340D
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2B18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU2B18NP340D
0.16 in. Dia. Retroreflective - 4 m (13’) Nominal Sensing Rangea (XUZC50 reflector included)
1.34 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU1B18PP340
4 mm Dia.
34 2.16 Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU1B18PP340D
55 Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU1B18NP340
XU●B18●P340 Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU1B18NP340D
Polarized Retroreflective - 1.5 m (4.9’) Nominal Sensing Rangea (XUZC50 reflector included)
Potentiometer Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU91B18PP340
0.16
LED Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU9B18PP340D

Not for Use on New


4.0
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9B18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU9B18NP340D
Proximity Diffuse - 60 cm (23.6’) Nominal Sensing Rangea

ns – Lim it e d P ro du c t Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5B18PP340

Applicatio
Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU5B18PP340D
1.34 Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5B18NP340
34 2.16 Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU5B18NP340D

Availability
55 Short Range Proximity Diffuse - 10 cm (4") Nominal Sensing Rangea
2.68
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8B18PP340
68
Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU8B18PP340D
XU●B18●P340D
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8B18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU8B18NP340D
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables

Marginal Detection Beam Break test (for thru-beam emitter only)


Thru-beam and reflex systems Beam made
.94 Beam broken
Dual Dimensions inches BN/1 BN/1
24 mm Signal 1.5
level 1
0.7
VI/2 VI/2
Red LED
Optimum
(alignment) BU/3 BU/3
LED off LED on
Excess Gain Curves (ambient temperature: +25° C)
Thru-beam Retroreflective Diffuse (Sn = 15 cm) Diffuse (Sn = 60 cm)
gain gain gain gain
500
300 50 50 50
2
30 30 30
100
20 20 20
50 15 15 15
1
10 10 10
7 7 7
10 5 5 5
5 3 3 3
2 2

1 1 1 1
0.1 0.2 0.5 1 2 3 6 15 0.1 0.25 0.5 1 2 34 5 10 0.1 0.5 1 2 5 10 20 60 0.2 0.5 1 5 40
0.1 2 15
0.3 0.8 5 10 20 0.7 D(m) 0.2 15 D(cm) 10 20 60
D(m)
D(cm)
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
1 Polarized reflex XU9B18XP340 White 90% White 90%
2 Reflex XU1B18XP340

70
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic - Front Sensing, DC

Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
Emitter Thru-beam receiver Operating -13° to 131° F (-25° to 55° C)
reflex and diffuse Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
1 (+) 1 (+) NEMA Type 4X (Indoor), 12
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
2 4 2 4
Test
Case PC/ABS
Program- Output
ming Enclosure Material Lens PMMA
3 (-)

Photoelectric Sensors
3 (-) Cable PVC
Mounting nuts 4 N•m (44.4 lb-in)
Light operate (no object present) Max. Tightening torque
Connector 2 N•m (17.7 lb-in)
Retroreflective Vibration resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
PNP output Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
OG LED indicator type 360° ring LED: shows output status
BN Cable 4 mm diameter cable, 4 x 0.22 mm2 c.s.a. (3x 0.22 mm2 for Thru-beam Emitter)
Connection
BK Connector 4 pin Micro style DC (M12 male)
BU Electrical
Voltage Range 12 – 24 Vdc
NPN output Voltage Limit (including ripple) 10 – 30 Vdc
OG Voltage Drop (across switch) closed state max. 1.5 V
BN Retroreflective 35 mA
Current Consumption (no load)
BK Proximity (diffuse) 35 mA
Max.
Thru-beam 50 mA
BU Load Current Max. 100 mA
Retroreflective 500 Hz
Diffuse Max. Operating frequency Proximity (diffuse) 500 Hz
Thru-beam 400 Hz
PNP output
OG On delay max. 1 ms
BN Retroreflective 1 ms
Off delay max Proximity (diffuse) 1 ms

Not for Use on New


BK Thru-beam 1.5 ms
BU Power-up delay max 30 ms
Short circuit protection Yes
NPN output

t
Overload protection Yes

ns – Lim
OG

it
BN

e d P ro du c Reverse polarity protection Yes

Applicatio
E 164869 LR 44087
BK Agency Listings CCN NRKH Class 3211 03
®

BU

Availability
Accessories
Dark operate (no object present)
Description Catalog Number
Retroreflective
Swivel ball mounting bracket XUZA218
PNP output Plastic mounting bracket XSZB118
BN Metal 90° Mounting bracket 9006PA18
BK Zinc diecast 90° Mounting bracket XUZA118
Plastic mounting nuts XSZE218
BU
Stainless Steel mounting nuts XSZE318
OG
90° mirror adapter for side sensing (Thru-beam only) Decrease sensing distance by 20% (0.80) XUBZ02
NPN output
90° mirror adapter for side sensing (All other models) Decrease sensing distance by 20% (0.80) XUBZ01
BN
BK
Detection Curves
BU
Thru-beam Reflex Diffuse (Sn = 10 cm) Diffuse (Sn = 40 cm)
OG Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
Diffuse 6 T/R 1.4 T/R
15 4 1 1 2
O 12 mm 2 1 1
PNP output T R T/R 2

BN 10 15 m 0.2 2 3 4 m 10 cm
-2 40 cm
-15 -4 -1 -1
BK -6 -1.4
BU Sn 15 m Sn 2 m (1) Sn 0.10 m Sn 0.40 m
OG Sn 4 m (2)
NPN output
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
BN (1) Polarized reflex XU9B18XP340 1 White 90% 1 White 90%
BK (2) Reflex XU1B18XP340 2 Grey 18% 2 Grey 18%
BU
OG

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

71
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, DC
18 mm Tubular, Metal Body / Classic - Front Sensing, DC

Features
thread
M18x1 • Housing: Metal • Sensing modes: Thru-beam (emitter and receiver
• Modulated LED output indication packaged together), Retroreflective, Polarized
Retroreflective (XUZC50 reflector included in
• Short circuit (SCP) reverse polarity and
Retroreflective models), Proximity Diffuse,
overload protection
Proximity Diffuse with Background Suppression
• Light/Dark selectable
• Connector versions available
Photoelectric Sensors

• 2 meter cable standard


• Self locking mounting nuts included
• Wide selection of mounting brackets
Dimensions • UL listed, CSA certified, and CE mark
available
.16 Potentiometer
Output Circuit Connection Load Current Operating Frequency Catalog
M18 x1 LED Mode Type
Voltage Range
Type Max. Max. Number
4
Thru-Beam System (Emitter - Receiver) - 15 m (48’) Nominal Sensing Range a
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2M18PP340
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2M18PP340D
.16 Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2M18NP340
2.16 Dia. Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2M18NP340D
5
55 3.15 Polarized Retroreflective - 4 m (13’) Nominal Sensing Rangea (XUZC50 reflector included)
80 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9M18PP340
XU●M18●P340 Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9M18PP340D
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9M18NP340
.16 Potentiometer Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9M18NP340D
4 M18x1 LED Proximity Diffuse - 50 cm (23.6’) Nominal Sensing Rangea
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5M18PP340
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5M18PP340D
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5M18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5M18NP340D
2.16 Proximity Diffuse with Adjustable Background Suppression - 10 cm (4") Nominal Sensing Rangea
55 3.15 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8M18PP340
80 3.62 Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU8M18PP340D
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8M18NP340
92
XU●M18●P340D Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU8M18NP340D
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
.94 c See p. 518 for matching connector cables
Dual Dimensions inches
mm 24 Marginal Detection Beam Break test (for thru-beam emitter only)
Verification of correct operation Beam made BN/1 Beam broken BN/1
Thru-beam and reflex systems
Variation of usable sensing VI/2 VI/2
Signal 1.5
level 1
0.7
Diffuse system with adjustable background
suppression. Potentiometer at minimum. BU/3 BU/3
Red LED
B
Optimum
(alignment)

LED off LED on

Excess Gain Curves (ambient temperature: +25° C)


Thru-beam Polarized retroreflective Diffuse (Sn = 40cm)
A 0.01 0.07 0.1 S (m) gain gain gain
0.08 100 10 10
80
50
Diffuse system with adjustable background 30
suppression. Potentiometer at maximum. 20 10
B
10 1
8
5
1
3
2

1 0.1 0.1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10
A 0.01 0.1 1 10 40 100
0.11 0.15 S (m) D (m) D (m)
0.12 D (cm)
With reflector XUZC50 Object 10 x 10 cm
A-B : Object reflection coefficient White 90%
Black 6% Sensing range
Grey 18% Non sensing range
White 90% (Matt surfaces)

72
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, DC
18 mm Tubular, Metal Body / Classic - Front Sensing, DC

Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
Emitter Thru-beam receiver, Operating -13° to 131° F (-25° to 55° C)
reflex and diffuse Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
1 (+) 1 (+) NEMA Type 4X, 12
Enclosure Rating
2 4 2 4 IEC Type IP67 conforming to IEC 60529
Test Program- Case Nickel plated brass
Output
3 (-) ming 3 (-) Enclosure Material Lens PMMA

Photoelectric Sensors
Cable PvR
Light operate (no object present) Mounting nuts 5 N•m (44.4 lb-in)
Max. Tightening torque
Connector 2 N•m (17.7 lb-in)
Retroreflective
Vibration resistance (IEC 60068-2-6) 25 gn, amplitude ± 2mm (f = 10 Hz to 55 Hz)
PNP output Shock resistance (IEC600 68-2-27) 30 gn, duration 11 ms
OG
LED indicator type 360° ring LED: shows output status
BN Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
Connection
BK Connector 4 pin Micro style DC (M12 male)
BU Electrical
Voltage Range 12 – 24 Vdc
NPN output Voltage Limit (including ripple) 10 – 30 Vdc
OG Voltage Drop (across switch)
1.5 V
BN closed state max.
BK Retroreflective 35 mA
Current Consumption (no load) Max. Proximity (diffuse) 35 mA
BU Thru-beam 50 mA
Load Current Max. 100 mA
Diffuse Max. Operating frequency 500 Hz
PNP output On delay max. 1 ms
OG Retroreflective 1 ms
BN Off delay max Proximity (diffuse) 1 ms
Thru-beam 1 ms
BK
Power-up delay max 15 ms
BU
Short circuit protection Yes
Overload protection Yes
NPN output
OG Reverse polarity protection Yes
BN E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
BK ®

BU Accessories
Dark operate (no object present)
Description Catalog Number
Retroreflective
Swivel ball mounting bracket XUZA218
PNP output Plastic mounting bracket XSZB118
BN Metal 90° Mounting bracket 9006PA18
Zinc diecast 90° Mounting bracket XUZA118
BK
Plastic mounting nuts XSZE218
BU
Stainless Steel mounting nuts XSZE318
OG 90° mirror adapter for side sensing (Thru-beam only)
NPN output XUBZ02
Decrease sensing distance by 20% (0.80)
BN 90° mirror adapter for side sensing (All other models)
XUBZ01
BK Decrease sensing distance by 20% (0.80)

BU Detection Curves
OG
Thru-beam Reflex Diffuse (Sn = 10 cm) Diffuse (Sn = 40 cm)
Diffuse Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
PNP output 6 T/R 1.4 T/R
15 4 1 1 2
T O 12 mm T/R 2 1 1
BN R 2

10 15 m 2 3 4 m
BK -2 0.2 10 cm 40 cm
-15 -4 -1 -1
BU -6 -1.4
OG Sn 15 m Sn 2 m (1) Sn 0.10 m Sn 0.40 m
NPN output Sn 4 m (2)

BN
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
BK (1) Polarized reflex XU9B18XP340 1 White 90% 1 White 90%
BU
(2) Reflex XU1B18XP340 2 Grey 18% 2 Grey 18%
OG

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

73
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, DC
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, DC

Features
thread
M18x1 • Housing: Metal • Sensing modes: Thru-beam (emitter and receiver
• Modulated LED output indication packaged together), Retroreflective, Polarized
Retroreflective (XUZC50 reflector included in
• Short circuit (SCP) reverse polarity and
Retroreflective models), Proximity Diffuse,
overload protection
Proximity Diffuse with Background Suppression
• Light/Dark selectable
• Connector versions available
Photoelectric Sensors

• 2 meter cable standard


• Self locking mounting nuts included
• Wide selection of mounting brackets
• UL listed, CSA certified, and CE mark
Dimensions available
0.16 Output Circuit
Voltage Range
Connection Load Current Operating Frequency Catalog
4.0 M18x1 LED Mode Type Type Max. Max. Number
Thru-Beam System (Emitter - Receiver) - 15 m (48’) Nominal Sensing Range a
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2M18PP340W
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2M18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU2M18NP340W
0.2in. Dia.
1.97 Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU2M18NP340WD
50 5mm Dia.
3.03 Polarized Retroreflective - 4 m (13’) Nominal Sensing Rangea (XUZC50 reflector included)
77 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9M18PP340W
XUkM18kk340W Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9M18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU9M18NP340W
0.16 Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU9M18NP340WD
4.0 M18x1 LED
Proximity Diffuse - 50 cm (23.6") Nominal Sensing Rangea
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5M18PP340W
Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5M18PP340WD
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5M18NP340W
Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU5M18NP340WD
1.97 Proximity Diffuse with Adjustable Background Suppression - 10 cm (4") Nominal Sensing Rangea
50 2.44 Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8M18PP340W
3.42 62 Light/Dark PNP 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU8M18PP340WD
87 Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8M18NP340W
XUkM18kk340WD Light/Dark NPN 12 to 24 V 4 pin Micro connector c 100 mA 500 Hz XU8M18NP340WD
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
Dual Dimensions inches c See p. 518 for matching cables.
mm

.94
24

Variation of usable sensing distance Beam Break test (for thru-beam emitter only)
Diffuse system with adjustable Diffuse system with adjustable A-B : Object reflection Beam made BN/1 Beam broken
background suppression background suppression BN/1
coefficient
Potentiometer at minimum Potentiometer at maximum
Black 6% VI/2 VI/2
B B Grey 18%
Non sensing range
(Matt surfaces) BU/3 BU/3
White 90%
Sensing range

A 0.01 0.07 0.1 A 0.01 0.11 0.15 S (m)


S (m)
0.08 0.12

Excess Gain Curves (ambient temperature: +25° C) Marginal Detection


gain Thru-beam gain Polarized retroreflective gain Diffuse (Sn = 40cm) Thru-beam and reflex systems
100 10 10
80
50
30 Signal 1.5
level 1
20 10 0.7
10 1
8 Red LED
5 1 Optimum
3 (alignment)
2
LED off LED on
1 0.1 0.1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10 0.1 1 10 40 100
D (m) D (m) D (cm)
With reflector XUZC50 Object 10 x 10 cm White 90%

74
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, DC
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, DC

Wiring Specifications
Mechanical
Connector
Thru-beam receiver, For usable sensing range, see excess gain curve charts
Emitter reflex and diffuse Operating -13° to 131° F (-25° to 55° C)
1 (+) 1 (+) Temperature Range
Storage -40° to 158° F (-40° to 70° C)
2 4 2 4 NEMA Type 4X (indoor), 12
Enclosure Rating
Test Program- Output IEC Type IP67 conforming to IEC 60529
3 (-) ming 3 (-) Case Nickel plated brass

Photoelectric Sensors
Enclosure Material Lens PMMA
Light operate Dark operate Cable PvR
(no object present) (no object present)
Mounting Nuts 5 N•m (44.4 lb-in)
Retroreflective Retroreflective Maximum Tightening Torque
Connector 2 N•m (17.7 lb-in)
PNP output OG PNP output Vibration Resistance (IEC600 68-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
BN
BN
BK Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BK
BU
BU LED Indicator Type 360° ring LED: shows output status
OG
NPN output Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
OG NPN output Connection
Connector 4 pin Micro style DC (M12 male)
BN BN
BK BK Electrical
BU BU
OG
Voltage Range 12 – 24 Vdc
Diffuse Diffuse Voltage Limit (Including Ripple) 10 – 30 Vdc
PNP output PNP output Voltage Drop (Across Switch) Closed State Maximum 1.5 V
OG
BN BN
Retroreflective 35 mA
BK Current Consumption (No Load)
BK Proximity (Diffuse) 35 mA
BU BU Maximum
OG
Thru-beam 50 mA
NPN output Load Current Maximum 100 mA
OG NPN output
BN BN Maximum Operating Frequency 500 Hz
BK BK
BU
On Delay Maximum 1 ms
BU
OG Retroreflective 1 ms
Off Delay Maximum Proximity (Diffuse) 1 ms
Thru-beam 1 ms
Power-up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®

Accessories
Description Catalog Number
Swivel Ball Mounting Bracket XUZA218
Plastic Mounting Bracket XSZB118
Metal 90° Mounting Bracket 9006PA18
Zinc Diecast 90° Mounting Bracket XUZA118
Plastic Mounting Nuts XSZE218
Stainless Steel Mounting Nuts XSZE318

Detection Curves
Thru-beam Polarized reflex Diffuse (Sn = 40 cm) Diffuse Background
suppression (Sn = 10 cm)
Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
6 T/R T/R
15 4 1 1
T O 12 mm R T/R 1 1
2
2
10 15 m 1 2 m
-2 0.2 40 cm 12 cm
-15 -4 -1
-6 -1
Sn 15 m Sn 2 m Sn 0.10 m
Sn 0.40 m
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
1 White 90% 1 White 90%
2 Grey 18% 2 Grey 18%

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

75
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, AC/DC
18 mm Tubular, Metal Body / Classic - Front Sensing, AC/DC

Features
• Housing: Nickel plated brass
• Modulated LED output indication
thread
• Short circuit (SCP) reverse polarity and overload protection
M18x1 • Sensing modes: Thru-beam (emitter and receiver packaged together), Retroreflective,
.16 Potentiometer Polarized Retroreflective (XUZC50 reflector included in Retroreflective models), Proximity
Photoelectric Sensors

M18 x1
4 LED Diffuse, Proximity Diffuse with Background Suppression
• Also available in side sensing style

.16
• 2 meter cable standard
Dia.
2.16 5 • Connector versions available
55 3.15
• Wide selection of mounting brackets available
80
XU●M18●230 • Self locking mounting nuts included
.16 Potentiometer • UL Listed, CSA Certified
4 M18x1 LED
• CE Mark
Voltage Load Operating
Circuit Output Voltage Connection Catalog
Drop Current Frequency
Type Mode Range Type Number
Max. Max. Max.
2.16 Thru-Beam System (Emitter - Receiver) – 15 m (48') Nominal Sensing Distance a
55 3.15
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU2M18MA230
80 3.62 .94 2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU2M18MA230K
92 24 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU2M18MB230
XU●M18●230K
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU2M18MB230K
Polarized Retroreflective – 2 m (6.6') Nominal Sensing Distance a (XUZC50 reflector included)
Variation of usable sensing
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU9M18MA230
distance 2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU9M18MA230K
Diffuse system with adjustable background 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU9M18MB230
suppression. Potentiometer at minimum. 2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU9M18MB230K
B Proximity Diffuse – 40 cm (15.7") Nominal Sensing Rangea
2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU5M18MA230
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU5M18MA230K
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU5M18MB230
2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU5M18MB230K
Proximity Diffuse with Background Suppression – 12 cm (4.7") Nominal Sensing Distance
A 0.01 0.07 0.1 S (m) 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU8M18MA230
0.08
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU8M18MA230K
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU8M18MB230
Diffuse system with adjustable background
2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU8M18MB230K
suppression. Potentiometer at maximum.
B a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables

Excess Gain Curves (ambient temperature: +25° C)


Thru-beam Polarized retroreflective Diffuse (Sn = 40cm)
gain gain gain
100 10 10
A 0.01 80
0.11 0.15 S (m)
0.12 50

30
A-B : Object reflection cefficient 20 10
Black 6% Sensing range
Grey 18% Non sensing range 10 1
8
White 90% (Matt surfaces)
5
1
Marginal Detection 3
2
Thru-beam and reflex systems
1 0.1 0.1
Signal 1.5 1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10 0.1 1 10 40 100
level 1 D (m) D (m)
0.7 D (cm)
With reflector XUZC50 Object 10 x 10 cm
Red LED White 90%
Optimum
(alignment) Dual Dimensions inches
mm
LED off LED on

76
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, AC/DC
18 mm Tubular, Metal Body / Classic - Front Sensing, AC/DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Thru-beam, reflex and diffuse Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 3
Storage - 40° to 158° F (- 40° to 70° C)
NEMA Type 4X, 12
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Case Nickel plated brass
Enclosure Material Lens PMMA

Photoelectric Sensors
2 wire
Cable PvR
AC/DC Receiver
Mounting nuts 5 N•m (44.4 lb-in)
BN +/- Max. Tightening torque
Connector 2 N•m (17.7 lb-in)
BU +/- Vibration resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
2 wire LED indicator type 360° ring LED: shows output status
AC/DC Emitter ConnectionAC/DC Cable 5 mm diameter cable, 2 x 0.34 mm2 C.S.A.
AC/DC Connector 3 pin Micro style AC/DC (M12 male)
BN +/-
Electrical
BU +/- Voltage Range AC/DC Models 24 – 240 Vac/dc
Voltage Limit (including ripple) AC/DC Models 20 – 264 Vac/dc
Voltage Drop (across switch)
AC/DC Models 6V
closed state max.
Residual leakage Current
AC/DC Models 1.5 mA
(Open State)
20 ≤ Vdc ≤ 58 IEC 60947-5-2 Utilization category DC-
Load Current AC/DC Models 10 – 200 mA 13
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Max. Operating frequency AC/DC Models 25 Hz
On delay max. AC/DC Models 20 ms
Retroreflective 20 ms
Off delay max Proximity (diffuse) 20 ms
Thru-beam 20 ms
Power-up delay max AC/DC Models 300 ms
Short circuit protection No
Overload protection No
Reverse polarity protection No
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®

Accessories
Description Catalog Number
Swivel ball mounting bracket XUZA218
Plastic mounting bracket XSZB118
Metal 90° mounting bracket 9006PA18
Zinc diecast 90° mounting bracket XUZA118
Plastic mounting nuts XSZE218
Stainless steel mounting nuts XSZE318
90° mirror adapter for side sensing (Thru-beam only)
XUBZ02
Decreases sensing distance by 20% (0.80)
90° mirror adapter for side sensing (All other models)
XUBZ01
Decreases sensing distance by 20% (0.80)
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, AC/DC

Detection Curves
Diffuse Background Suppression
Thru-Beam System Polarized Reflex Diffuse (Sn = 40 cm)
(Sn = 10 cm

6
1 1
15 4
2
1 2 3 m 0,3 60 cm 12 cm
10 15 20 m -2 0,2
-15 -4 -1 -1
-6
2

With reflector XUZ C50 Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %, 2 : Gray 18 %

Connector Cables (U20 or K suffix)


XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

77
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, AC/DC
Features
thread
• Housing: Nickel plated brass • Sensing modes: Thru-beam (emitter and receiver
M18x1
• Modulated LED output indication packaged together), Polarized Retroreflective
(XUZC50 reflector included in Retroreflective
• Short circuit (SCP) reverse polarity and
models), Proximity Diffuse, Proximity Diffuse with
overload protection
Background Suppression
• 2 meter cable standard
• Also available in side sensing style
Photoelectric Sensors

• Connector versions available


• Self locking mounting nuts included
• Wide selection of mounting brackets
• UL Listed, CSA Certified, CE marked
available
Dimensions Circuit Output Voltage Connection
Voltage Load Operating
Catalog
Drop Current Frequency
Type Mode Range Type Number
0.16 Max. Max. Max.
4.0 M18x1 LED Thru-Beam System (Emitter - Receiver) - 15 m (48’) Nominal Sensing Distance a
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU2M18MA230W
2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU2M18MA230WK
2 wire Light 24-240 V 2M (6.6’) cable 6V 200 mA 25 Hz XU2M18MB230W
0.2in. Dia. 2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU2M18MB230WK
1.97 Polarized Retroreflective - 2 m (6.6’) Nominal Sensing Distance a (XUZC50 reflector included)
50 5mm Dia.
3.03 2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU9M18MA230W
77 2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU9M18MA230WK
XUkM18kk340W 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU9M18MB230W
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU9M18MB230WK
0.16 Proximity Diffuse - 40 cm (15.7") Nominal Sensing Rangea
4.0 M18x1 LED 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU5M18MA230W
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU5M18MA230WK
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU5M18MB230W
2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU5M18MB230WK
Proximity Diffuse with Background Suppression - 12 cm (4.7") Nominal Sensing Distance
1.97 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU8M18MA230W
50 2.44 2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU8M18MA230WK

3.42 62 2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU8M18MB230W


87 2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6V 200 mA 25 Hz XU8M18MB230WK
XUkM18kk340WD a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables.

Variation of usable sensing distance


Diffuse system with adjustable Diffuse system with adjustable A-B : Object reflection
background suppression background suppression coefficient
Potentiometer at minimum Potentiometer at maximum
Black 6%
B B Grey 18%
.94 Dual Dimensions inches
24 mm Non sensing range
(Matt surfaces)
White 90%
Sensing range

A 0.01 0.07 0.1 A 0.01 0.11 0.15 S (m)


S (m)
0.08 0.12

Excess Gain Curves (ambient temperature: +25° C) Marginal Detection


gain Thru-beam gain Polarized retroreflective gain Diffuse (Sn = 40cm) Thru-beam and reflex systems
100 10 10
80
50

30 Signal 1.5
level 1
20 10 0.7
10 1
8 Red LED
5 1 Optimum
3 (alignment)
2
LED off LED on
1 0.1 0.1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10 0.1 1 10 40 100
D (m) D (m) D (cm)
With reflector XUZC50 Object 10 x 10 cm White 90%

78
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, AC/DC
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, AC/DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Thru-beam, reflex and diffuse
Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 3 Storage - 40° to 158° F (- 40° to 70° C)
NEMA Type 4X (indoor), 12
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Case Nickel plated brass

Photoelectric Sensors
2 wire Enclosure Material Lens PMMA
AC/DC Receiver Cable PvR
BN +/- Mounting Nuts 5 N•m (44.4 lb-in)
Maximum Tightening torque
Connector 2 N•m (17.7 lb-in)
BU +/-
Vibration Resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
2 wire
AC/DC Emitter LED Indicator Type 360° ring LED: shows output status

BN +/- ConnectionAC/DC Cable 5 mm diameter cable, 2 x 0.34 mm2 c.s.a.


AC/DC Connector 3 pin Micro style AC/DC (M12 male)
BU +/-
Electrical
Voltage Range AC/DC Models 24 – 240 Vac/dc
Voltage Limit (Including Ripple) AC/DC Models 20 – 264 Vac/dc
Voltage Drop (Across Switch)
AC/DC Models 6V
Closed State Maximum
Residual Leakage
AC/DC Models 1.5 mA
Current (Open State)
10 – 200 20 ≤ Vdc ≤ 58 IEC 60947-5-2 Utilization category DC-13
Load Current AC/DC Models
mA Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Maximum Operating Frequency AC/DC Models 25 Hz
On Delay Maximum AC/DC Models 20 ms
Retroreflective 20 ms
Off Delay Maximum Proximity (Diffuse) 20 ms
Thru-beam 20 ms
Power-up Delay Maximum AC/DC Models 300 ms
Short Circuit Protection No
Overload Protection No
Reverse Polarity Protection No
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®

Accessories
Description Catalog Number
Swivel Ball Mounting Bracket XUZA218
Plastic Mounting Bracket XSZB118
Metal 90° Mounting Bracket 9006PA18
Zinc Diecast 90° Mounting Bracket XUZA118
Plastic Mounting Nuts XSZE218
Stainless Steel Mounting Nuts XSZE318
See page 94 for complete assembly.

18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, AC/DC

Detection Curves
Diffuse Background Suppression
Thru-Beam System Polarized Reflex Diffuse (Sn = 40 cm)
(Sn = 10 cm

6
1 1
15 4
2
1 2 3 m 0,3 60 cm 12 cm
10 15 20 m -2 0,2
-15 -4 -1 -1
-6
2

With reflector XUZ C50 Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %, 2 : Gray 18 %

Connector Cables (U20 or K suffix)


XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . .Page 156

79
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Stainless Steel Tubular
Front Sensing, DC
18 mm Stainless Steel Tubular Front Sensing, DC

Features
thread
M18x1 • Housing: Stainless Steel
• Food and Beverage Rated
• Mounting Nuts included
• UL Listed, CSA Certified
Photoelectric Sensors

• CE Marked
Load
Circuit Voltage Connection Operating
Output Mode Current Catalog Number
Type Range Type ♦ Frequency
Max.
Thru-Beam (emitter & receiver) – 15m (48’) Nominal Sensing Distance
Dimensions - Front Sensing Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18PP341
0.16 Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18NP341
4 M18x1 (1)
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341D
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341D
Retroreflective – 4m (13’) Nominal Sensing Distance (reflector sold separately)
dia. 0.19 Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18PP341
1.96 5 0.94
50 2.4 24 Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18NP341
62 (2) Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18PP341D
XU•N18••341 Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18NP341D
Polarized Retroreflective – 2m (6.6’) Nominal Sensing Distance
0.16 Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18PP341
4 M18x1 (1)
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18NP341
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18PP341D
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18NP341D
1.96 0.94 Proximity Diffuse – 10cm (4”) Nominal sensing Distance
50 2.4 24
Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18PP341
62 2.8
72
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18NP341
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18PP341D
XU•N18••341D
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18NP341D
♦ 5m cable length available with L5 suffix
Dual Dimensions inches
mm
Excess Gain Curves
Thru-beam Retroreflective Polarized Retroreflective Diffuse

100 100 10
80
50
50
20 30
30
20
20 10 15
10 1 10
8 7
5 5
1
3
3
2 2

1 0,1 0,1 1
1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,5 1 1,5 3 5 0,1 0,2 0,5 1 2 5 10 20 60
0,1 0,2 0,5 1 45 10
D (m) D (m) D (cm)
D (m)

With Reflector XUZC50 With Reflector XUZC50 Object 10 x 10 cm White 90%

80
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Stainless Steel Tubular
Front Sensing, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3
Temperature Range Operating -13 deg to +131 deg F (-25 deg to +55 deg C)
Storage -40 deg to +158 deg F (-40 deg to +70 deg C)
1 2
Enclosure Rating NEMA Type 4X (indoor), 12
1 (+) 1 (+) IEC Type IP67 Double Insulated
Enclosure Material Case Stainless Steel

Photoelectric Sensors
2 4 2 4
Test Program- Output Lens PMMA
3 (-)
ming 3 (-) Cable PVR
Maximum Tightening Torque Mounting nuts 15 Nm (133.3 lb-in)
Light operate (no object present) Connector 2 Nm (17.7 lb-in)
Vibration Resistance (IEC 68868-2-6) 7g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Retroreflective - PNP output
OG Shock Resistance (IEC 60068-2-27) 30g, duration 11ms
BN LED indicator Output Yellow
Connection Cable 5mm O.D. 4 conductor 0.34mm2
BK
Connector 4 pin Micro style DC (M12)
BU
Electrical
Diffuse - PNP output Voltage Range 12 – 24 Vdc
OG Voltage Limit (including ripple) 10 – 30 Vdc
BN Voltage Drop (across switch) closed state maximum 1.5 V
BK Current Consumption (no load) maximum 30mA (reflex & diffuse), 50mA (thru-beam)
BU Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
Retroreflective - NPN output On Delay Maximum 1 ms
OG
Off Delay Maximum 1 ms
BN
Power up Delay Maximum 15 ms
BK
Short Circuit Protection Yes
BU Overload Protection Yes
Diffuse - NPN output Reverse Polarity Protection Yes
OG Agency Listings UL CSA CE
BN
BK
Accessories
BU Description Catalog Number
Reflector 50x50mm XUZC50
Dark operate (no object present) 90 degree metal mounting bracket XUZA118
Retroreflective - PNP output Plastic clamp mounting bracket XUZA218
BN 3-D mounting bracket (Stem nut included) XUZB2003
BK M12 stem XUZ2001
BU
Detection Curves
OG
Diffuse - PNP output Thru-beam Retroreflective Polarized Retroreflective Diffuse
BN 1,4
6
15 10 1
BK Ø 12 mm 4 2 1
4 2
BU
10 15 m 4 m 1,5 2 m 10 cm
OG -4 2 -2 0,2
-15 -4 -1
-10 -1,4
Retroreflective - NPN output -6
Sn ≤ 0,10 m
BN
BK Object: 3.9 x 3.9" (10 x 10 cm)
With Reflector XUZC50 With Reflector XUZC50
1: White 90%, 2: Grey 18%
BU
OG
Beam Break Test (For thru-beam emitter only)
Diffuse - NPN output
Beam Made Beam Broken
BN
BK BN/1 + BN/1 +
BU
OG VI/2 VI/2

BU/3 – BU/3 –

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

81
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Stainless Steel Tubular
90 Degree Sensing, DC
18 mm Stainless Steel Tubular 90 Degree Sensing, DC

Features
thread
M18x1 • Housing: Stainless Steel
• Food and Beverage Rated
• Mounting Nuts included
• UL Listed, CSA Certified
Photoelectric Sensors

• CE Marked
Load
Circuit Voltage Connection Operating
Output Mode Current Catalog Number
Type Range Type ♦ Frequency
Max.
Thru-Beam (emitter & receiver) – 15m (48’) Nominal Sensing Distance
Dimensions Side Sensing Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18PP341W
0.16
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18NP341W
4 M18x1 (1) Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341WD
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341WD
Retroreflective – 4m (13’) Nominal Sensing Distance (reflector sold separately)
dia. 0.19 Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18PP341W
1.96 5 0.94
50 3.07 24 Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18NP341W
78 Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18PP341WD
XU•N18••341W Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18NP341WD
Polarized Retroreflective – 2m (6.6’) Nominal Sensing Distance
Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18PP341W
0.16
4 M18x1 (1) Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18NP341W
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18PP341WD
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18NP341WD
Proximity Diffuse – 10cm (4”) Nominal sensing Distance
1.96 0.94
50 24
Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18PP341W
2.4
62 2.8
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18NP341W
88 Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18PP341WD
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18NP341WD
XU•N18••341WD
♦ 5m cable length available with L5 suffix

Excess Gain Curves


Dual Dimensions inches
mm
Thru-beam Retroreflective Polarized Retroreflective Diffuse

100 100 10
80
50
50
20 30
30
20
20 10 15
10 1 10
8 7
5 5
1
3
3
2 2

1 0,1 0,1 1
1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,5 1 1,5 3 5 0,1 0,2 0,5 1 2 5 10 20 60
0,1 0,2 0,5 1 45 10
D (m) D (m) D (cm)
D (m)

With Reflector XUXC50 With Reflector XUXC50 Object 10 x 10 cm White 90%

82
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Stainless Steel Tubular
90 Degree Sensing, DC
18 mm Stainless Steel Tubular 90 Degree Sensing, DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3
Temperature Range Operating -13 deg to +131 deg F (-25 deg to +55 deg C)
Storage -40 deg to +158 deg F (-40 deg to +70 deg C)
1 2
Enclosure Rating NEMA Type 4X (indoor), 12
1 (+) 1 (+) IEC Type IP67 Double Insulated
Enclosure Material Case Stainless Steel

Photoelectric Sensors
2 4 2 4
Test Program- Output Lens PMMA
3 (-)
ming 3 (-) Cable PVR
Maximum Tightening Torque Mounting nuts 15 Nm (133.3 lb-in)
Light operate (no object present) Connector 2 Nm (17.7 lb-in)
Vibration Resistance (IEC600 68-2-6) 7g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Retroreflective - PNP output
OG Shock Resistance (IEC 60068-2-27) 30g, duration 11ms
BN LED indicator Output Yellow
Connection Cable 5mm O.D. 4 conductor 0.34mm2
BK
Connector 4 pin Micro style DC (M12)
BU
Electrical
Diffuse - PNP output Voltage Range 12 – 24 Vdc
OG Voltage Limit (including ripple) 10 – 30 Vdc
BN Voltage Drop (across switch) closed state maximum 1.5 V
BK Current Consumption (no load) maximum 30mA (reflex & diffuse), 50mA (thru-beam)
BU Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
Retroreflective - NPN output On Delay Maximum 1 ms
OG
Off Delay Maximum 1 ms
BN
Power up Delay Maximum 15 ms
BK
Short Circuit Protection Yes
BU Overload Protection Yes
Diffuse - NPN output Reverse Polarity Protection Yes
OG Agency Listings UL CSA CE
BN
BK
Accessories
BU Description Catalog Number
Reflector 50x50mm XUZC50
Dark operate (no object present) 90 degree metal mounting bracket XUZA118
Retroreflective - PNP output Plastic clamp mounting bracket XUZA218
BN 3-D mounting bracket (Stem nut included) XUZB2003
BK M12 stem XUZ2001
BU
Detection Curves
OG
Diffuse - PNP output Thru-beam Retroreflective Polarized Retroreflective Diffuse
BN 1,4
6
15 10 1
BK Ø 12 mm 4 2 1
4 2
BU
10 15 m 4 m 1,5 2 m 10 cm
OG -4 2 -2 0,2
-15 -4 -1
-10 -1,4
Retroreflective - NPN output -6
Sn ≤ 0,10 m
BN
BK Object: 3.9 x 3.9" (10 x 10 cm)
With Reflector XUZC50 With Reflector XUZC50
1: White 90%, 2: Grey 18%
BU
OG

Diffuse - NPN output Beam Break Test (For thru-beam emitter only)
BN Beam Made Beam Broken
BK
BU BN/1 + BN/1 +
OG
VI/2 VI/2

BU/3 – BU/3 –

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

83
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
High Excess Gain, Thru Beam, DC
18 mm Tubular, Metal Body / High Excess Gain, Thru Beam, DC

Features
thread
M18x1 • Very high excess gain of 250,000 at 10 cm with strength to “burn through” polluted
environments such as in car washes or lumber milling applications
• Two distinct outputs: analog and digital with PNP output
• Analog can gauge density with sharp precision, as in hopper fill applications
• Digital output is ideal for detecting the presence of an object in nearly opaque packaging
Photoelectric Sensors

• One catalog number for both emitter and receiver


• Housing is metal with metal mounting nuts included in carton.
• Four pin Micro connector standard
• UL Listed, CSA Certified
Dimensions
• CE Mark
.16
M18x1 (2) (1)
4 Operating
Output Circuit Voltage Load Current Catalog
Connection Type Frequency
Mode Type Range Maximum Number
Maximum
Thru-Beam System (Emitter–Receiver) – 50m (164') Nominal Sensing Rangea
Dark PNP 12 to 24 Vdc 4 pin Micro Connector c 100 mA 30 Hz XU2M18AP20D
2.16
55 3.23 a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
82 3.74 c See p. 518 for matching connector cables.
95
Excess Gain Curves (ambient temperature: +25° C)
(1) LEDs
(2) Potentiometers gain
(Receiver Only) 5
.94 3
24 2

10 5
Dual Dimensions inches 8
mm
5
3
2

Beam Pattern 10 4
8
Dia. of beam 5
cm
3
2
15
Ø 12 mm
10 3
800
70 m
500
-15 300
200
Sn ≤50 m
100
80
50
30
20

10
8
5
3
2

1
0.1 0.2 0.3 0.5 1 2 3 5 10 20 30 50 100
D(m)

84
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
High Excess Gain, Thru Beam, DC
18 mm Tubular, Metal Body / High Excess Gain, Thru Beam, DC

Wiring Specifications
Mechanical
1 + For usable sensing range, see excess gain curve chart
2 Ie = 4 to 20 mA Operation -13° to 131° F (-25° to 55° C)
Temperature Range
mA Storage - 40° to 158° F (- 40° to 70° C)
Ie = 0 to 100 mA
4 NEMA Type 3, 4, 4X, 6, 12, 13
R
Enclosure Rating
3 R IEC Type IP67 conforming to IEC 60529
– Vibration 7 G amplitude + 1.5 mm (f=10 to 55 Hz)
R maxi < 800 Ω (Ue = 24 V), < 300 Ω (Ue = 12 V)

Photoelectric Sensors
Shock Resistance 30 G for 11 ms conforming to 68-2-27
Mounting Nuts 15 N•m (133 lb-in)
Tightening Torque
Connector 2 N•m (17.7 lb-in)
Beam Break Test (Emitter Only)
Repeatability (% of Sr) 3%
+ One green power LED c
LED Indicator Type
1 One yellow output LED c
2 Enclosure Material Nickel plated brass
Wiring 4 pin Micro connector
3 Electrical
– Voltage Limit (Including Ripple) 10 – 30 Vdc
Beam Made
Current Consumption (Maximum) (No Load) 55 mA (emitter and receiver)
+ Voltage Drop (Maximum) 1.5 V
1 Analog Output Range 4 to 20 mA
2 At -25° to 55° C 10%
Current Drift Due to Temperature
At 0° to 40° C 5%
3 Current Drift Due to Alignment 3%
– Power-up Delay (Maximum) 50 ms
Beam Broken
On Delay (Maximum) 15 ms
Off Delay (Maximum) 15 ms
Discrete (on/off) Output Green LED is illuminated c
Connector LED Operation
Analog Output Yellow LED is illuminated c
Emitter Receiver Short Circuit Protection Yes
1 (+) 1 (+) Protective Circuitry Overload Protection Yes
Reverse Polarity Protection Yes
2 4 2 4 E 164869 LR 44087
Test Analog Solid State Agency Listings CCN NRKH Class 3211 03
®
Output Output
3 (–) 3 (–)
c See description of LED operation below.

Operation of LEDs in the Analog mode


When sensing a slightly opaque target at 20 mA, LED is illuminated at its maximum strength.
When sensing a target that is completely opaque at 4 mA, LED is illuminated at its minimum
strength.

Discrete (On/Off) Output


Level of Change
Potentiometer Potentiometer
Type of Target: Opaque Analog Output Curve at Minimum at Maximum

Amount Output Current


mA
25

0 to 99.5% 20
18

15
99.5 to 99.95%
10

5
99.95 to 100% 4

0
0 0.1 99.4 99.5 99.6 99.7 99.8 99.9 99.95 100% 0 1 0 1
Amount of Opaque
Example

Detection of number of sheets of white paper weighing 80 g (2.8 oz) with emitter and receiver at 10 cm apart.
Connector Cables (M12 or D suffix) Number of sheets 1 11 27 31
XSZCD101Y Micro Conn., 4 pin, 2 m, straight Analog output current (mA) 17,3 12 6 5
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157

85
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Analog Output, Proximity Diffuse, DC
18 mm Tubular, Metal Body / Analog Output, Proximity Diffuse, DC

Features
thread
M18x1 • 4 to 20 mA output, rather than discrete (on/off) output. As target characteristics change,
output adjusts accordingly
• Analog technology in popular 18 mm diameter body style
• Rugged metal enclosure with Micro style connector
• Potentiometer adjusts sensor’s sensitivity and reduces the color effects of the target
Photoelectric Sensors

• Self locking mounting nuts included


Dimensions • UL Listed, CSA Certified
.16 • CE Mark
4 M18x1 (1) (2)

Output Circuit Voltage Operating Frequency Catalog


Connection Type
Mode Type Range Maximum Number
Proximity Diffuse 50 to 400 mm (2 to 15.7") Nominal Sensing Range
2.16
Light Analog 12 to 24 Vdc 4 pin Micro Connector c 20 Hz @ 10 mA XU5M18AB20D
55 3.23
82 c See p. 518 for matching connector cables.
3.74
95
(1) Potentiometer
(2) Green LED
Output Signal (relative to distance/color)

Potentiometer at Maximum

.94 Is (mA)
24 25

20
Dual Dimensions inches
mm
15

2 1
10

5
4

1
0 10 20 30 40 50
D (cm)
Target Color
1 White 90%
2 Grey 15%

Potentiometer at Minimum

Is (mA)
25

20

2 1
15

10

5
4
1
0 10 20 30 40 50
D (cm)
Target Color
1 White 90%
2 Grey 15%

86
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Analog Output, Proximity Diffuse, DC
18 mm Tubular, Metal Body / Analog Output, Proximity Diffuse, DC

Wiring Specifications
Mechanical
Connector
Operation -13° to 131° F (-25° to 55° C)
1 (+) Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
Analog 2 4 NEMA Type 3, 4, 4X (Indoor), 6, 12, 13
Output Enclosure Rating
IEC Type IP67 per IEC 56029, IP671 per NFC 20-010
3 (–)
Vibration 7 G amplitude + 1.5 mm (f=10 to 55 Hz)

Photoelectric Sensors
1 + Shock Resistance 30 G for 11 ms conforming to 68-2-27
2 Mounting Nuts 15 N•m (133 lb-in)
Ie = Tightening Torque
R 4 to Connector 2 N•m (17.7 lb-in)
mA 20 mA
D Repeatability (% of Sr) 3%
3 –
LED Indicator Type One green LED showing output
Enclosure Material Nickel plated brass (window is PMAA)
Wiring 4 pin Micro connectorc
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (Including Ripple) 10 – 30 Vdc
Current Consumption (Maximum) (No Load) 30 mA
Output Range 4 mA to 20 mA
At -25° to 55° C 10%
Maximum Output Current Drift
At 0° to 40° C 5%
Power-up Delay (Maximum) 50 ms
Light Emission Infrared
At 20 mA LED burns brightly (at maximum)
LED Intensity
At 4 mA LED burns dimly (at minimum)
Short Circuit Protection Yes
Protective Circuitry Overload Protection Yes
Reverse Polarity Protection Yes
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®

c See p. 518 for matching connector cables.

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157

87
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Ultra Violet (UV), DC
18 mm Tubular, Metal Body / Ultra Violet (UV), DC

Features
thread
M18x1
• For detection of Ultra Violet marks and products containing UV blueing agents, as used for
packaging identification and quality assurance.
• Either Mark Reader or standard Diffuse sensing modes
• Sensitivity adjustment by 20 turn potentiometer
• 20 ms Off Delay built in timing feature
Photoelectric Sensors

• Popular 18 mm tubular body style in rugged metal enclosure with a 4 pin micro style
connection
Load Operating
Circuit Output Voltage Connection Catalog
Current Frequency
Type Mode Range Type Number
Max. Max.

Diffuse - 20 mm (0.787") Nominal Sensing Rangea — Micro Style Connector


PNP Light 12 - 24 Vdc 4 pin Micro connector 100 mA 1000 Hz XU5M18U1D
a Excess gain one - in normal ambient conditions, maximum usable sensing distance is 75% of normal

Dimensions Detection Curve

.16 cm
4 3
M18x1 (1) (2)

2 8 cm

2.16 3
55 .94
3.23 24
82 Target 5 x 5 cm, white 90%
3.79
95 Spot size at 20 mm
Oval Dia. 3 x 1 mm
1.Potentiometer
2. Green LED Dual Dimensions inches
mm

88
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Ultra Violet (UV), DC
18 mm Tubular, Metal Body / Ultra Violet (UV), DC

Wiring Specifications
Mechanical
Connector
20 mm when reading UV mark
1 (+) Nominal sensing range
0 to 80 mm as standard diffuse
Time Delay 2 4 Output UV spot dimensions 0.12 x 0.04 " (3 x 1 mm) diameter
(1) Operation -13° to 131° F (-25° to 55° C)
3 (–) Temperature range
Storage -40° to 158° F (-40° to 70° C)

Photoelectric Sensors
Off delay: Enclosure rating IEC Type IP67 conforming to IEC 60529
For no delay, connect contact 2 to (+) Tightening Torque 15 N•m/11 lb-ft.
For 20ms delay, connect contact 2 to (-) Vibration 7G amplitude + 0.6 mm (f=10 to 55 Hz)
Shock resistance 30gn for 11 ms conforming to IEC 60068-2-27
1 +
4 LED indicator type Red - output
Enclosure material Nickel Plated Brass (window is PMAA)
3 – Sensitivity Adjustment 20 turn potentiometer
2
Connection M12, 4 pin connector
Without time delay
Light emission Ultra Violet

1 + Electrical DC models
4 Voltage Range 12 - 24 V (with SCP)
Voltage limit (including limit) 10 - 30 Vdc
3 –
2 Operating Frequency 1000 Hz
Current consumption (max.)(no load) 20 mA
With time delay (20ms)
Voltage drop (max.) 1.5V PNP
Power-up delay (max.) 100 ms
On delay (max.) 500 µs
Off delay (max.) 500 µs
Timing function 20 ms “off delay” selectable by wiring
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®

0.79"
20 mm
spot : 3x1 mm

Color Mark Reader

3.15"
80 mm

Diffuse Mode
WH 90% Kodak
2x2" (5x5cm)
Dual Dimensions inches
mm

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157

89
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Laser, Thru-beam Mode, DC
18 mm Tubular, Plastic Body / Laser, Thru-beam Mode, DC

Features
thread
M18x1 • Extremely long sensing distance of 100 meters (328 ft) in an 18mm tubular body
• Can detect very small objects
• Adjustable beam (or focus point) down to 0.5mm
• System checking and marginal detection LEDs
Photoelectric Sensors

• “Reserve Mode” option increases beam strength for visible alignment during setup
• Mounting nuts and adjustment screwdriver included
• Micro style connector standard c
• UL Listed, CSA Certified
Load
Circuit Output Voltage Operating
Current Catalog Number
Type Mode Range Frequency Max.
Max.

Thru-beam Emitter-Receiver – 100m (328') Nominal Sensing Distance a


PNP Light/Dark 12-24 Vdc 100 mA 500 Hz XU2P18PP340DL
NPN Light/Dark 12-24 Vdc 100 mA 500 Hz XU2P18NP340DL
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables

Adjustments Beam break test

ON
1 +
2
2
3 –

OFF
1 +
2

3 –
1
The adjustment of the focusing point enables the detection of targets down XU2P18kP340DLR XU2P18KP340DLT
to a size of 0.5 mm.
To adjust the focusing point, loosen the fixing screws (1) and rotate the
serrated sleeve (2) located on the face of the sensor.
Re-tighten fixing screws.
Note: Saddle clamp XUZA218 incorporating a ball joint (see page 94) is
particularly suited for mounting the detector and adjusting the beam
alignment when the sensing range is several tens of meters.

Detection curve (set to infinity) Verification of correct operation

cm 1.5
Signal 1
level 0.7
LED off
Red LED LED on

Optimum
Sn = 100 m – alignment
+

Operating precautions

CAUTION

LASER RADIATION —
DO NOT STARE INTO BEAM

CLASS II LASER PRODUCT


This product complies with CFR 1040.1

90
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Laser, Thru-beam mode, DC
18 mm Tubular, Plastic Body / Laser, Thru-beam Mode, DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Emitter
Operation 14° F to +113° F (-10° C to +45° C)
Temperature range
1 (+) Storage -40° F to +158° F (-40° C to +70° C)
Enclosure rating IEC IP67 conforming to IEC 60529
2 4
Tightening torque (max.) 4 N•m (35.5 lb-in)
Test

Photoelectric Sensors
7 G, amplitude +/- 1.5 mm (f = 10 to 55 Hz)
3 (–) Vibration
conforming to IEC 60068-2-6
Receiver Shock resistance 50 gn for 11ms conforming to 68-2-27
Case PC/ABS
1 (+) Enclosure material
Lens PMMA
2 4
Wiring Micro style connector
Programm Output
ing Electrical
3 (–)
Voltage range 12 to 24 Vdc
Emitter Voltage limit (including ripple) 10 to 30 Vdc

1 Voltage drop (across switch), closed state 1.5 V


Maximum load current 100 mA
3
Current consumption (max.) (no load) 50 mA (emitter and receiver)
Test
2 Maximum operating frequency 500 Hz
On delay (max.) 1 ms
Light mode (no object present) Off delay (max.) 1 ms
Receiver Power-up delay (max.) 15 ms
PNP output Physical Characteristics
2
Red laser 630 nm
1 + Emitter wave length:
1 mW, class 2 conforming to IEC 60825-1 and CFR 1040.1
4 – Transmission power (max.) Short circuit protection yes
3
Overload protection yes
Protective Circuitry
Reverse polarity protection yes
NPN output
2
Agency Listings
1 + ®

4

3
Excess gain curve (ambient temperature: +25° C)
Dark mode (no object present)
Receiver mm
PNP output 12
10
1 +
Minimum size of the
object to be sensed

4 –
3 1
2
0.5
NPN output
1 + 0.1
4 0.1 0.3 1 2 10 20 100 (m)
– Focusing point
3
2
Dimensions
.157
4
(2)
(1)

1.18 M18x1 .94


30 2.48 24
63 2.99
76 Dual Dimensions inches
mm

(1) LED

(2) Adjustment potentiometer (receiver only)


Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157

91
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUB Plus 18 mm Short Body
Transparent Material Detection, DC
XUB Plus 18 mm Short Body / Transparent Material Detection, DC

2.17" Features
thread
55
M18x1 • Ultra short body
• Adjustable sensitivity
• Light/Dark selectable
• Short circuit and overload protection
1.34"
Photoelectric Sensors

34 • Advanced features: 360° multi-functional LED indicator: Output on, Marginal detection
indicator and short circuit indicator, and transparent object detection in retroreflective mode
2.17"
55 • UL Recognized, CSA Certified, CE Mark
Load
Circuit Output Voltage Operating
Current Catalog Number
Type Mode Range Frequency Max.
Max.
Retroreflective – 31.5" (80 cm) Nominal Sensing Range c - 2 m (6.6') cable (Reflector
sold separately)
1.34" 3 wire, PNP Light/Dark 12-24 V 100 mA 500 Hz XUBH01353
34
2.76" 3 wire, NPN Light/Dark 12-24 V 100 mA 500 Hz XUBJ01353
70
Retroreflective – 31.5" (80 cm) Nominal Sensing Range - Micro Style Connector f
(Reflector sold separately)
Dual Dimensions inches
mm 3 wire, PNP Light/Dark 12-24 V 100 mA 500 Hz XUBH01353D
3 wire, NPN Light/Dark 12-24 V 100 mA 500 Hz XUBJ01353D
c When used with XUZC50 reflector. 24" (60 cm) sensing range when used with XUZC24 reflector.
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
f See p. 518 for matching connector cables

Recommended distances and Recommended Excess gain curve


application restraints approach (ambient temperature: 77° F, (+25 ° C))
direction
5
(lens on horizontal plane,
horizontal passage of target) 4

(1) (1) 1
(2) 10 20 30 50 80 100 D (cm)
E
(1) 5 cm min.
(2) Sensor-reflector distance With reflector XUZC50
(see table below)
On

Correct alignment – LED Off

D On
ff

– LED
DO

Off
ent – LE

ED
– LE

Sensor-reflector distance
ent

–L

Material Reflector
ent

alignm

l alignm

nt

0 20 cm 40 cm 60 cm 80 cm
me
gnm

lign
li

XUZC50
al
a

Margina

ct a
Margin
t

Tinted glass
rrec

orre

XUZC24
Inco

Inc

XUZC50
PVC bottles
XUZC24
R
XUZC50
RED LED off Clear glass
XUZC24
RED LED on
XUZC50
PET bottles
XUZC24

XUZC50
PE film
XUZC24

92
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUB Plus 18 mm Short Body
Transparent Material Detection, DC
XUB Plus 18 mm Short Body / Transparent Material Detection, DC

Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
1 (+) Temperature range -13° F to +131° F (-25° C to +55° C)
Program- 2 4 Output Enclosure rating IEC IP67 (IEC 60529)
ming
Enclosure material Case PC/ABS, Lens PMMA

3 (-) Tightening torque (max.) 44 lb-in (5 N•m)

Photoelectric Sensors
Vibration resistance 7 G, amplitude +/- 1.5 mm (f= 10 to 55 Hz)
Shock resistance 50 G, for 11ms
PNP output + light Cable: PvR, 0.16" (4 mm2) dia.
Prog.
OG
BN
- dark
Conductors: 24 AWG (0.222 mm2)
H
BR
Load
Electrical
BU
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 30 Vdc
Voltage drop (across switch), closed state 1.5 V
NPN output Maximum load current 100 mA
BN
J Current consumption (no load) 35 mA Retroreflective
BR Load

BU Maximum operating frequency 500 Hz

OG
+ light On delay (max.) 1 ms (1.5 ms thru-beam)
Prog.
- dark Off delay (max.) 1 ms (1.5 ms thru-beam)
Power-up delay (max.) 30 ms
Short circuit protection Yes
Overload protection Yes
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Protective Circuitry
Fast transients (motor start/stop
IEC 61000-4-4, L3a (1 kV)
interference)
Beam Pattern Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E 164353 LR 44087
cm Agency Listings CCN NKCR2 Class 3211 03
®
6
4 Physical Characteristics
E/R 2
Ambient light immunity 10,000 Lux

-2 .2 2 3
m Emitter wave length: Retroreflective 880nm Pulsed Infrared LED
-4 a L indicates level number.
-6 Sn: ≤ 2 m

Sn: ≤ 3 m Options
With reflector XUZC50 Description Suffix
Polarized reflex Extended cable length (5 meter (16’) cable) L05
Reflex Extended cable length (10 meter (33’) cable) L10

Accessories
Description Catalog Number
Mounting bracket (metal) 9006PA18
Universal mounting bracket (plastic) XSZB118
90° mirror adapter for side sensing (All other models)
PA18 XUBZ01
Decrease sensing distance by 20% (0.80)

XUBZ01

XSZB118

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories. . . . . . . . . . . . . . . . . . . . . . Page 94, 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

93
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular
Accessories, Replacements
18 mm Tubular / Accessories, Replacements

Accessories
Description Catalog Number
Plastic swivel ball mounting bracket (18 mm) XUZA218
Plastic mounting bracket XSZB118
Metal 90° mounting bracket 9006PA18
XUZA218 Zinc diecast 90° mounting bracket XUZA118
Plastic mounting nuts XSZE218
Photoelectric Sensors

Stainless steel mounting nuts XSZE318


90° mirror adapter for side sensing (Thru-beam only)
XSZB118 Classic type only XUBZ02
Decreases sensing distance by 20% (0.80)
90° mirror adapter for side sensing (All other models)
Classic type only XUBZ01
Decreases sensing distance by 20% (0.80)
3-D Mounting base XUZ2003
M12 Stem (75 mm usable length) XUZ2001
3-D Mounting bracket (stem not included) XUZB2003
9006PA18
Thru-Beam Emitter and Receiver Replacements
For Replacement of
Description Catalog Number Description
Emitter/Receiver Pair
XUZA118
Classic Metal XU2M18MC230T Emitter Only
XU2M18MA230
AC/DC, Dark Operate XU2M18MA230R Receiver Only
Classic Metal XU2M18MC230T Emitter Only
XU2M18MB230
AC/DC, Light Operate XU2M18MB230R Receiver Only
.94
24

Classic Metal AC/DC XU2M18MC230KT Emitter Only


XU2M18MA230K
Dark Operate, Micro Connector XU2M18MA230KR Receiver Only
Classic Metal AC/DC XU2M18MC230KT Emitter Only
.94 XU2M18MB230K
Light Operate, Micro Connector XU2M18MB230KR Receiver Only
24
Classic Metal AC/DC XU2M18MC230L5T Emitter Only
XUBZ01 XU2M18MA230L5
Dark Operate, 5 Meter Cable XU2M18MA230L5R Receiver Only
Classic Metal AC/DC XU2M18MC230L5T Emitter Only
XU2M18MB230L5
Light Operate, 5 Meter Cable XU2M18MB230L5R Receiver Only
Classic Metal DC, NPN XU2M18KP340T Emitter Only
XU2M18NP340
.94
24

Light/Dark Operate XU2M18NP340R Receiver Only


Classic Metal DC, NPN XU2M18KP340DT Emitter Only
XU2M18NP340D
Light/Dark Operate, Micro Connector XU2M18NP340DR Receiver Only
Classic Metal DC, NPN XU2M18KP340L5T Emitter Only
.94 XU2M18NP340L5
Light/Dark Operate, 5 Meter Connector XU2M18NP340L5R Receiver Only
24
XUBZ02 Classic Metal DC, PNP XU2M18KP340T Emitter Only
XU2M18PP340
Light/Dark Operate XU2M18PP340R Receiver Only
Classic Metal DC, PNP XU2M18KP340DT Emitter Only
XU2M18PP340D
Light/Dark Operate, Micro Connector XU2M18PP340DR Receiver Only
Classic Metal DC,PNP XU2M18KP340L5T Emitter Only
XU2M18PP340L5
Light/Dark Operate, 5 Meter Connector XU2M18PP340L5R Receiver Only
Classic Plastic DC NPN XU2B18KP340T Emitter Only
XU2B18NP340
Light/Dark Operate XU2B18NP340R Receiver Only
Classic Plastic DC NPN XU2B18KP340DT Emitter Only
XU2B18NP340D
Light/Dark Operate, Micro Connector XU2B18NP340DR Receiver Only
Classic Plastic DC PNP XU2B18KP340T Emitter Only
XU2B18PP340
Light/Dark Operate XU2B18PP340R Receiver Only
Classic Plastic DC PNP XU2B18KP340DT Emitter Only
XU2B18PP340D
Light/Dark Operate, Micro Connector XU2B19PP340DR Receiver Only
Laser XU2P18KP340DLT Emitter Only
XU2P18NP340DL
Light/Dark Operate, NPN XU2P18NP340DLR Receiver Only
Laser XU2P18KP340DLT Emitter Only
XU2P18PP340DL
Light/Dark Operate, PNP XU2P18PP340DLR Receiver Only

XUZB2003, XUZ2001, XUZ2003

94
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular
Accessories Dimensions
18 mm Tubular / Accessories Dimensions

Dimensions
XUZA218
.39 1.77 .73
10 Dia.
45 18.5
.31 .94 .31
8 24 8
.25
6.5

o
150

Photoelectric Sensors
.20

1.06
27
.98
25
5

19.5
.77
2.16 15 o
55

XUZA118

.10 .59
2.5 15
.73 .04
Dia. .39 .25
18.5 1
1.38 10 6.5
35

16.5
.65
1.10 .25 .79
28 6.5 20
1.97
50

XSZB118
1.51 .71
38.3 Dia.
18
.45
11.5
.87
22

20.1
.79

.14
.62 3.5
(1) 15.7
1.02
26

.16 .87 .31


4 22 8

9006PA18

35
18 1.38
0.69 10 18 2
0.40 0.71 0.08

Full R
31 40 33
1.20 1.57 1.28

5
0.21
18 25 13 Dia. Hole
Dia Dual Dimensions inches
0.69 0.98 0.49 mm

XUZB2003 XUZ2001 XUZ2003

0.22 0.76
1.4 5.75 19.5
0.76
19.5

∅ 0.72 M4 36 0.86
18.5 22.0
1.3
33

∅ 0.25
1.6
40

0.47 ∅ 0.5 6.5


0.07

12 12.5
1.9
120
4.7

1.57
0.9 40
23
0.9
23

95
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM L Miniature
Classic Economy, DC
XUM L Miniature / Classic Economy, DC

Miniature economy, high performance photoelectric sensors for industrial applications.


Features:
• Very small dimensions: 1.3" x 1" x 0.47" (33 x 25.4 x 11.9mm)
• Test input on thru-beam emitter allows remote sensor system checking
• Light/Dark selectable
Photoelectric Sensors

• Short range proximity mode for background suppression


• Very long thru-beam and retroreflective range
• Polarized retroreflective mode for shiny target detection
• Blinking red LED short circuit visible indicator
Cable Version • Quick connect versions
• Mounting bracket included
• UL Listed, CSA Certified
Load Operating
Output Voltage Catalog
Type Current Frequency
Mode Range Number
Max. Max.
Thru-beam – Nominal Sensing Range 43' (13m) a f
2m cable
Emitter – 12-24 V 100 mA – XUMLH0803
Receiver PNP Light/dark 12-24 V 100 mA 400 Hz XUMLH0854
Receiver NPN Light/dark 12-24 V 100 mA 400 Hz XUMLJ0854
Connector Nano style-4 pin
Emitter – 12-24 V 100 mA – XUMLH0803S
Connector Version Receiver PNP Light/dark 12-24 V 100 mA 400 Hz XUMLH0854S
Receiver NPN Light/dark 12-24 V 100 mA 400 Hz XUMLJ0854S

Retroreflective – Nominal Sensing Range 19' (6m) a (Reflector sold separately) f


2m cable
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH0451
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ0451
Connector Nano style-4 pin c
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH0451S
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ0451S

Polarized Retroreflective – Nominal Sensing Range 13' (4m) a (Reflector sold separately)
2m cable
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH0259
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ0259
Connector Nano style-4 pin c
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH0259S
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ0259S

Proximity Diffuse – Nominal Sensing Range 2.3' (.7m) a


2m cable
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH4055
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ4055
Connector Nano style-4 pin c
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH4055S
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ4055S

Short Range Proximity Diffuse – Nominal Sensing Range 10" (.25m) a


2m cable
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH1055
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ1055
Connector Nano style-4 pin c
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH1055S
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ1055S
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables
f Alignment LED

96
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM L Miniature
Classic Economy, DC
XUM L Miniature / Classic Economy, DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Emitter Temperature range -13° F to +131° F (-25° C to +55° C)
Test 2 4 NEMA Type 1, 3, 4, 6, 6P (cable only), 12, 13
Enclosure rating
IEC Type IP65 conforming to IEC 60529
1 3
+ – Enclosure material Housing: ABS/PC; Lens; PMMA, PC; Cable: PVC

Photoelectric Sensors
Vibration resistance 7G amplitude ± 1.5 mm (f= 10 to 55 Hz)
Shock resistance 50G 3 axes, 3 times

Receiver (reflex and prox diffuse) Wiring cable versions 6' cable, .18" dia., 3, 4 x #24 AWG

Light/dark Electrical
selector Output Voltage Limit q (including ripple) 10 - 30 Vdc
2 4
Load current max. 100 mA, protected against overload and short circuit
1 3 Voltage drop “closed” state 1.5 V
+ – No load current consumption max. 50 mA - receiver, emitter; 35 mA -reflex, diffuse
Test input voltage max. 1.5 V @ 1 mA max.
Receiver Switching frequency max. 500 Hz (400 Hz for thru beam)
PNP Output (Sourcing) Power up delay max. 30 ms
+ Light On/Off delay max. 1 ms (1.5 ms for thru beam)
Select
Polarized - red 660 nm
OG - Dark
Wavelength Proximity short range 660 nm
BN
H All others 880 nm
BK
BU
LOAD
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
NPN Output (Sinking)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
BN Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
H
BK E 164869 LR 44087
LOAD

BU Agency Listings CCN NRKH Class 3211 03


®

+ Light q Inverse polarity protection.


OG Select
a L indicates level number.
- Dark
Accessories
Test Input: (beam break)
Emitter only Description Sensing distance Catalog Number
Thru-beam aperture 0.5 mm diameter 4.5 cm (1.78") XUMZ01
E Black
+ Thru-beam aperture 1.0 mm diameter 4.5 cm (1.78") XUMZ02
Thru-beam aperture 2.0 mm diameter 4.5 cm (1.78") XUMZ03
Purple (violet)
cable versions XUZA47
Bracket (spare)
connector versions XUZA46

Blue

Normal (Emitter ON): open contact Excess gain curves


Test (Emitter OFF): closed contact
Thru-beam Retroreflective Proximity Diffuse
gain gain gain
50 50

100 20 20
2 2
10 10
1
5
1
10 5

1 1 1
0.1 1 10 2 10 20 50 100 200 500 1000 2 1 2 5 10 20 50 100
8 D (m) 400 D (cm) 40 D (cm)
With reflector 1 Polarized Target 10 x 10cm, 1 Short range
XUMZ0k XUZ C50 2 Infra-red White 90% 2 Standard diffuse
Thru-Beam Aperture

Connector Cables (M8 or S suffix)


XSZCS141 Nano Conn., 4 pin, 2 m, straight
XSZCS151 Nano Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . . . . Page 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

97
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM Miniature, High Performance
Classic, DC
XUM Miniature, High Performance / Classic, DC

High performance, self contained medium range miniature photoelectric sensors for industrial
applications.
Features:
• Very small dimensions: 1.4" x 0.87" x 0.39" (35.5 X 22 X 9.9mm) fixed.
• Marginal Detection Signal (MDS) provided for alarm output and alignment help.
Photoelectric Sensors

• Test input – system checking


• Light/Dark selectable
• Short range proximity mode for background avoidance
• Polarized retroreflective mode for shiny target detection
• Color mark detection. Green and red light for difficult contrast sensing
• 2 LED alignment system
• NEMA Type 4, 6, 6P ratings
• Mounting bracket included.
• UL Listed, CSA Certified
Output Voltage Options Load Operating Catalog
Type
Mode Range (See Page 99) Current Max. Frequency Max. Number
Thru-beam – Nominal Sensing Range 33' (10 m) a
Emitter 2 wire & test 12-24 V t/c XUMH07301

Not for Use on New


Receiver PNP 3 wire Light /dark 12-24 V c 100 mA 500 Hz XUMH073534
Receiver NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ073534

Retroreflective – Nominal Sensing Range 13' (4 m) a (Reflector sold separately)

ns – Lim it e dE
P ro du c t PNP 3 wire Light /dark 12-24 V c 100 mA 500 Hz XUMH03353

Applicatio
NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ03353

Polarized Retroreflective – Nominal Sensing Range 6.6' (2 m) a (Reflector sold separately)

Availability
On

Correct alignment – LED Off

D On

PNP 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMH023539


Off

Off

NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ023539


nt – LE

ent – LE
LED

ED

Proximity diffuse – Nominal Sensing Range 3' (.9 m) a


–L
nt –

e
alignm

l alignm

nt
nme

me

PNP 3 wire Light /dark 12-24 V c 100 mA 500 Hz XUMH703535


lign
lig

NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ703535


al
ta

Margina

ct a
Margin
rrec

Short range proximity diffuse – Nominal Sensing Range 5" (.13 m) a


orre
Inco

Inc

PNP 3 wire Light /dark 12-24 V c 100 mA 500 Hz XUMH103535


NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ103535
R
Convergent Beam q – Sensing Range 0.6" (15 mm) a
RED LED off Red light
RED LED on
PNP 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMH15353R
Marginal Alignment Indication NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ15353R
t 5 meter cable option
c 10 meter cable option
q XUM Color mark detector, red and green light, see p. 134.
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.

Front face of reader diameter of light


spot at 15 mm : 2 mm
(side view)
3.5 mm 3.5 mm

optical
axis
recommended
16" operating zone

A B

15 mm Depth of field (mm) A B


red emission 5 10

98
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM Miniature, High Performance
Classic, DC
XUM Miniature, High Performance / Classic, DC

Wiring Specifications
Mechanical
PNP output For usable sensing range, see excess gain curve charts
+ Light Temperature range -13° F to 131° F (-25° C to 55° C)
Select

OG - Dark
NEMA Type 1, 3, 4, 6, 6P, 12, 13
Enclosure rating
BN IEC Type IP67 conforming to IEC 60529
H BK
LOAD
Enclosure material Housing: ABS/PC; Lens: PMMA,PC; Cable: PVC
BU
Vibration resistance 7G amplitude ± 1.5 mm (f = 10 to 55 Hz)

Photoelectric Sensors
LOAD
W MDS Shock resistance 50G 3 axes, 3 times
Wiring 6’ cable, .18" dia., 3 x #24 AWG
Electrical
Voltage limit (including ripple) 10-30 Vdc
NPN output Load current max. 100 mA, protected against overload and short circuit
Voltage drop “closed” state 1.5 V
MDS
No load current consumption 30 mA - receiver; 20 mA - emitter 35 mA - reflex, diffuse
W
BN
LOAD
Test output current max. 50 mA
J BK LOAD Test input voltage max. 1.5 V @ 1 mA max.
BU
Switching frequency max. 500 Hz
+ Light
OG SELECT Power up delay max. 1 ms
- Dark On/Off delay max. 1 ms
Polarized 660 nm
Wavelength Convergent (red) 660 nm
All others 880 nm
Beam break test (purple wire) Ambient light immunity 10,000 LUX
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
E DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Brown + Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)

Not for Use on New


Purple Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®

ns – Lim it e d P ro du c t
Blue - a L indicates level number.

Applicatio
Beam present Options
Description Selected Versions Suffix

Availability
5m (16') cable on selected versions t L05
E 10m (33') cable on selected versions c L10
Brown +

Accessories
Purple
Description Sensing Distance Catalog Number
Thru-beam aperture (1) 0.5 mm and (1) 1 mm 4.5 cm (1.78") XUMZ01
Thru-beam aperture (1) 1.5 mm and (1) 2 mm 4.5 cm (1.78") XUMZ03
Blue -

Beam broken
Excess gain curves
Thru-beam Reflex Diffuse
gain gain gain
100
0 target 20 X 20
500 RF 30
300 50
white 90 %
40
0.7 m
100 20 20
50 15 infrared 15
10 10 0.1 m
7 9
10
5 3 3

D (m) polarized D (m) D (cm)


1 1 1
0.1 0.2 0.3 0.5 0.8 1 2 4 5 7 10 0.05 0.08 0.1 0.25 0.5 0.7 1 2 3 4 1 2 4 6 8 10 20 40 90 100

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Page 165


Beam patterns. . . . . . . . . . . . . . . . . . . . . . . Page 159
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

99
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUK Sub-compact
Classic – AC/DC, DC with Timer
XUK SubCompact / Classic - AC/DC, DC wtih Timer

Features:
• Increasingly popular rectangular body style perfect for mounting flat against machine wall
• Versatility is incorporated in every mode of detection
• Universal features makes retrofit easy
• 10 sec., three mode programmable time delay
Photoelectric Sensors

• Thru Beam pair sold as one number


• Reflector included in Retro reflector models
1.97
50
1.57 • High gain reserve produces superior sensing distances
40
• Smallest multi voltage time-delay photo available
• Mounting bracket (adapts to competitor’s model) included
• Hinged locking plastic cover protects adjustments.
Load Operating
Circuit Output Voltage Catalog
Current Frequency
.19 2xØ4 Type Type Range Number
Max. Max.
5
1.57 Thru-beam (Emitter - Receiver) – 30 m (98.4') Nominal Sensing Distance a
40 Cable style - 2 Meter (6.6’) length c
AC/DC relay Light/Dark 24 - 240 V 3A 20 Hz XUK2ARCTL2
PNP/NPN Light/Dark 12 - 24 V 100 mA q 20 Hz XUK2AKSAL2
Micro style connector
1.57
40

1.34
1.57

PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK2AKSAM12


40

34

Not for Use on New


Retroreflective – 10 m (32.8') Nominal Sensing Distance a (XUZC50 reflector included)
2 Meter (6’) length cable c
AC/DC relay Light/Dark 24 - 240 V 3A 20 Hz XUK1ARCTL2
10°

n s –
Ø4,5

L im ite d P ro d u c t Polarized Retroreflective – 6 m (19.7') Nominal Sensing Distance a (XUZC50 reflector

Applicatio
2.30
58 included)
Cable style - 2 Meter (6.6’) length c

it y E x c e p t fo r X U K 8 AC/DC relay Light/Dark 24 - 240 V 3A 20 Hz XUK9ARCTL2

Availabil
1.57

PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK9AKSAL2


1.97 40

Micro style connector

le
50

ju s ta b PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK9AKSAM12


.79

d
20

Proximit y D if fu s e A Proximity Diffuse – 1.5 m (4.9') Nominal Sensing Distance a


Cable style - 2 Meter (6.6’) length c
AC/DC relay Light/Dark 24 - 240 V 3A 20 Hz XUK5ARCTL2

High Percision
.71 .86
18 22 PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK5AKSAL2
Micro style connector
Ø6x12 .47 .27 PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK5AKSAM12
12 7
Proximity Diffuse – 1 m (3.3') Nominal Sensing Distance – Adjustable High Precision
Cable style - 2 Meter (6.6’) length c
2.30
.71

58
18

PNP/NPN Light/Dark 12 - 24 V 100 mA 250 Hz XUK8AKSNL2


.59
15 Micro style connector
Ø6 .51 PNP/NPN Light/Dark 12 - 24 V 100 mA 250 Hz XUK8AKSNM12
13
c For 10 meter cable, change L2 suffix to L10.
q 50 mA alarm output
Ø6x13 a Excess gain one - in nominal ambient conditions maximum usable sensing distance is 75% of normal
.47 .19
12 5 Excess gain curves
2.56 Thru-beam Retroreflective Proximity Diffuse Adustable Proximity Diffuse
65 gain gain %
20
500 10 18
50
30
1 7 16
100 25
14
50 15 5
12
3.23

10 4
82

7 10
10
2 3
8
5 3 2
3.15

6
80

4
1 1
0,1 0,2 0,4 0,8 2 4 6 10 20 30 0,7 1,5 3 5 7 10 20 70 100 1 2
0,6 1 8 D (m) 1 2 30 50 D (m) 0 0,5 1 1,5 2
D (m) 0
With Reflector 1. Polarized Retroreflective 0 20 40 60 80 100
2. Retroreflective 1 White 90 % 3 Black 6%
2 Gray 18%

Dual Dimensions inches


mm

100
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUK Sub-compact
Classic – AC/DC, DC with Timer
XUK SubCompact / Classic - AC/DC, DC with Timer

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3
Temperature range Operation -13° to 131° F (-25° to 55° C)
Storage -30° to 158° F (-30 to 70° C)
1 2
Enclosure rating NEMA Type 4, 4X (indoor), 12, 13
IEC Type IP65 conforming to IEC 60529
PNP Yellow on
Vibration 7G amplitude (f=10 to 55 Hz) Conforming to IEC 60068-2-6

Photoelectric Sensors
BN + Shock resistance 10gn for 11 ms conforming to 68-2-27
BK Wiring 22 AWG (.34 mm2)
– Tightening torque (max.) 5 N•m (44.4 lb-in)
BU
Case PC/ABS
Enclosure material Lens PMMA
Cable PvR
NPN Yellow on Electrical
AC/DC DC
BN + Voltage limit (including ripple) 21.6 - 264 Vac 10 - 30 Vdc
BK Voltage drop (across switch, closed state) — 1.5 V

BU Current consumption (max.)(no load) — 35 mA with SCP
Yellow Output LED yes yes
Red Stability LED no yes
Relay Wiring Power-up delay (max.) 60 ms 80 ms
On delay (max.) 25 ms 0.5 ms
Light switching (no object present)
Thru-beam receiver and reflex Off delay (max.) 25 ms 0.5 ms
Diffuse Short Circuit Protection —
BN BN
GY GY Protective Circuitry Overload Protection yes
WH WH
Reverse polarity protection — yes

Not for Use on New


BK BK
BU BU E164869 Pending
Agency Listings CCN NRKH
Dark switching (no object present) ®

Thru-beam receiver and reflex


BN

n s
Diffuse

– L im ite d P ro d u c t BN
Options

Applicatio
GY GY
WH WH
BK BK Description Suffix
BU BU

8
10 Meter (33’) length cable L10

Transmitter
it y E x c e p t fo r X U K
Availabil
1.L.ON D.ON
BN 6 2.TIM. ON OFF Timing Function

y D if
BU

fu s e A d ju s ta ble 1 1.Light on - Dark on

Proximit 2 2.Timer on - Timer off


AC/DC Cable Connections 3 3.Delay / One shot

High Percision
4 4.On Delay / Off Delay
BU (Blue) 7 T 8
BN (Brown) 5 5.PNP or NPN
Relay common WH (White) T = Time delay
N.O. contact BK (Black) 6.Yellow LED - output on
N.C. contact GY (Grey) 3.DL 1 SHOT
7.Red LED - alignment and alarm
4.ON OFF
5. PNP NPN 8.Self teaching button (SET)
Recommended mounting
distances Detection Curves
max. 1.5 m
Thru-beam Retroflective Proximity Diffuse
min. 0
Dia. of beam (Copn) (Copn)
cm cm
10 cm
10
8
5 Ø 16 mm 5 4

20 30 m 0,2
5 7 10 m
-4
1 m
-5 -5
-8
-10 -10 Sn ≤ 1 m
Sn 5 m (1)

Sn 20 m Sn 7 m (2)

1. Polarized Retroflective Object 20 x 20 cm


2. Retroreflective White 90%
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . Page 157
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

101
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUC Compact Limit Switch Body Style
DC or AC/DC Timer
XUC Compact Limit Switch Body Style / DC or AC/DC Timer

Features:
• Sleek but rugged compact body with • Two 360° LED indicators (output and
very long sensing distances stability)
• Solid state (NPN or PNP selectable) or • Light/Dark selectable
Relay output (N.O./N.C.) • Hinged transparent cover protects
• Built in 0-15 second timer option on adjustments
Photoelectric Sensors

AC/DC models • Cable or connector versions


• Alarm Output on DC versions (see p.518 for cables)
• Adjustable background Suppression in • 30 mm cylindrical base with mounting nuts
Diffuse modes included
• Oversized potentiometer for sensitivity • UL rated for outdoor use, NEMA type 4X
adjustment • CE Mark
.14
1.77 4
Operating
45 Circuit Output Load Current Catalog
Voltage Range Frequency
Type Type Maximum Number
Maximum
Thru-beam (Emitter - Receiver) – 60 M (196') Nominal Sensing Distance d
3.74 Cable style – 2 Meter (6.6') length
95
1.71 AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC2ARCTL2
43 Ø 5.5
PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC2AKSAL2
Mini style connector
.71 AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC2ARCTU78
.21 18 Micro style connector
5
PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC2AKSAM12
.90
23 Polarized Retroreflective (XUZC50 reflector included) – 9 M (29.5') Nominal Sensing
1.33 M5
34 Screws Distanced
Cable style – 2 Meter (6.6') length
M30 x 1.5
- Max. Torque 20 Nm AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC9ARCTL2

DC Models PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC9AKSAL2


Micro (M12) Connector Mini style connector
- Max. Torque 2 Nm
AC/DC Models AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC9ARCTU78
Mini (U78) Connector Micro style connector
-Max. Torque 5 Nm
PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC9AKSAM12

3.06 Proximity Diffuse with Adjustable Background Suppression – 1.2 M (3.9') Nominal
78
Sensing Distance d
150°
1.73 Cable style – 2 Meter (6.6') length
44
AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC8ARCTL2
PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC8AKSNL2

3.95 Mini style connector


100 AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC8ARCTU78
Micro style connector
PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC8AKSNM12

f With 0–15s timer option.


.77
20 d Excess gain one–in normal ambient conditions, maximum usable sensing distance is 75% of normal.
Beam Patterns
cm cm cm 1 white object
1.38 2 1
2 black object
35 60
10 8
Dual Dimensions inches Ø 16 mm 5 4
mm
60 m 6 9 m 1.3 m
0.2
-5 -4
-10 -8
-60 Sn 1.15 m

Sn 50 m Sn 6 m Sn 1.2 m
Thru-Beam Retroflective Diffuse

Accessories . . . . . . . . . . . . . . . . . . . . . . . . Page 157


Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

102
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUC Compact Limit Switch Body Style
DC or AC/DC Timer
XUC Compact Limit Switch Body Style / DC or AC/DC Timer

Verification of Correct Operation Specifications


1.15
Signal 1 Mechanical
.85
LED Off For usable sensing range, see Excess Gain Curve Charts
Red LED LED On Temperature range Operation -13 to 131° F (-25 to 55° C)
Optimum Storage -40 to 158° F (-40 to 70° C)
– Alignment +
Enclosure rating NEMA Type 3, 4, 4X (outdoor use), 6, 6P, 12, 13
Programming AC/DC Model IEC Type IP67 conforming to IEC 60529
Vibration 7 G amplitude + 1.5 mm (f = 10 to 55 Hz)

Photoelectric Sensors
Delay
Range T1 T2 Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
1 2 Light T1 T2 Time
6789 Case PC/ABS
On 0 to 2s Delay
Enclosure Material Lens PMMA
6 7 8 9 Cable PvR
Dark 0 to 15s Delayed Electrical
3 4 5 On One Shot
AC/DC DC
T2
T1 Voltage limit (including ripple) 20 - 264 Vac/dc 10 - 38 Vdc
LED Potentiometers
1 Output 3 Sensitivity
Voltage drop (across switch, closed state) — 1.5 V
2 Instability 4 T1 50 mA (thru-beam)
Power current consumption (max.) (no load) 2W
5 T2 35 mA (others)
Switches
6 Light On / Dark On Power-up delay (max.) 60 ms 15 ms
7 T1 = On Delay Time 0-2s or 0-15s On delay (max.) 25 ms 1 ms
8 T2 = Off Delay Time or One Shot Off delay (max.) 25 ms 1 ms
Time 0-2s or 0-15s
9 Time Delay / One Shot: 0-2s or 0-15s Red LED: stability yes no
Yellow LED: output yes yes
Wiring E164869
Agency Listings CCN NRKH
AC/DC (5-Wire ) ®

Transmitter
BN/4
Options
BU/2 Description Suffix
Light switching (no object present) 5 Meter (16.4') Cable L5
Thru-beam receiver and reflex
BN/4
Diffuse
BN/4 Mounting Brackets
WH/5 WH/5
GY/3 GY/3
BK/1 BK/1 Description Catalog Number
BU/2 BU/2
Swivel Ball Bracket (plastic) XSZSB30
Dark switching (no object present)
Thru-beam receiver and reflex 90 ° Bracket (steel) 9006 PA30
Diffuse
BN/4 BN/4
WH/5 WH/5
Excess gain curve (ambient temperature: +25° C)
GY/3 GY/3
BK/1 BK/1
BU/2
Thru-beam system Reflex system With reflector Variation of usable sensing distance
BU/2
gain gain XUZ-C50 Diffuse system with adjustable
Connector schemes XUC•ARCTU78 10000 background suppression
Thru-beam Thru-beam receiver, 40 B
transmitter reflex and diffuse 1000 30
3 Relay Common 20
3
4 2 4 2 100 10
5 1 5 1 5
N.C. N.O. 10 A 0.05 1.10 1.50 S (m)
Cable connections XUC•ARCTL• 1.30
BU (Blue) 1 1 A-B : Object reflection coefficient
BN (Brown) 1 2 5 10 80100 0.1 0.2 0.4 0.8 2 3 5 7 10 Black 6% Sensing range
Relay common GY (Grey) D (m) 0.6 1 4 6 9 D (m) Grey 18% Non sensing zone
N.O. contact BK (Black) White 90%
N.C. contact WH (White)

DC (3-Wire ) Cable connections


Diffuse
Light switching (no object present) NPN output PNP output Beam broken Transmitter XUC•AKS•L•
Thru-beam receiver and reflex BN/1 + BN/1 + + BN/1 +
BN/1 (–) BU (Blue)
PNP output – (+) BN (Brown)
BN/1 + BK/4 BK/4 V1/2
– – BU/3 – (OUT) BK (Black)
BU/3
BU/3 BU/3
BK/4 Alarm WH (White)
– Dark switching (no object present) NPN output Alarm output (for thru-beam
BN/1 + Test VI (Violet)
BU/3 Thru-beam receiver and reflex and reflex systems only)
NPN output PNP output PNP Connector schemes XUC-•AKS•M12
BN/1 + BN/1 + BK/4 BN/1 +
– Thru-beam Thru-beam receiver,
BK/4 BK/4 BU/3 WH/2 transmitter reflex and diffuse
– – – (–) Output (–)
BU/3 BU/3
Beam break test
BU/3 Signal 4
Diffuse (for thru-beam transmitter only) 4 3 3
PNP output NPN output Beam made + NPN
BN/1 + BN/1 + BN/1 +
BN/1
BK/4
– 1 2 1 2
BK/4 V1/2 WH/2
– – – (+) Test input (+) Alarm output
BU/3 (except diffuse)
BU/3 BU/3 BU/3

Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA1501Y Mini Conn., 5 pin, 2 m, straight
XSZCA9501Y Mini Conn., 5 pin, 2 m, 90°
For additional cable options and lengths see p. 518

103
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUL Sub-compact
DC, AC/DC
XUL SubCompact / DC, AC/DC

Features:
• Subcompact medium range self contained • Side or front mounting
photoelectric sensors for industrial • LED visible from two directions (front, top)
applications
• Easy to wire (45° cable entry)
• DC or AC/DC solid state output, AC/DC
• Cable or connector options available ➁
relay output
• 2-wire solid state output saves wiring time
Photoelectric Sensors

• The XUL 2-wire solid state AC/DC output


provides substantially longer life than • Universal 24-240Vac/dc power supply
conventional relays. Ideally suited for • Double insulated enclosure, i.e., no
Cable
intensive material handling applications grounding required
• Economical • Programmable light, dark (DC only)
• Small size • UL Listed
• Flat lenses
Voltage range Load Operating
Output Catalog
Type current frequency
mode AC max. DC max. number
max. k max.
Thru beam – Nominal Sensing Range 33' (10 m) a
AC/DC – 6' (2 m) cable
Emitter – 20-264 V 20-60 V – – XULM0600
Receiver 5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM080314
DC – 6' (2 m) cable
Emitter 2 wire – – 10-30 V – – XULK 0830
Micro style connector

Not for Use on New


Receiver 3 wire, PNP Light/dark – 10-30 V 200 mA 200 Hz XULH083534
Receiver 3 wire, NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ083534
Retroreflective – Nominal Sensing Range 25' (8 m) a (Reflector sold separately)

n s – L im ite d P ro d u c t
AC/DC – 6' (2 m) cable

Applicatio
Solid state output Light 20-264 V 20-60 V 500 mA 20 Hz XULA06021
Solid state output Dark 20-264 V 20-60 V 500 mA 20 Hz XULA06011
5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM06031

Availability
DC – 6' (2 m) cable
3 wire PNP Light/Dark – 10-30 V 200 mA 250 Hz XULH06353
3 wire NPN Light/Dark – 10-30 V 200 mA 250 Hz XULJ06353
Polarized Retroreflective – Nominal Sensing Range 16' (5 m) a (Reflector sold separately)
AC/DC – 6' (2 m) cable
Solid state output Light 20-264 V 20-60 V 500 mA 20 Hz XULA040219
Solid state output Dark 20-264 V 20-60 V 500 mA 20 Hz XULA040119
5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM040319
DC – 6' (2 m) cable
3 wire PNP Light/dark – 10-30 V 200 mA 200 Hz XULH043539
3 wire NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ043539
Proximity Diffuse – Nominal Sensing Range 2.3' (.7 m) a
AC/DC – 6' (2 m) cable
Solid state output Light 20-264 V 20-60 V 500 mA 200 Hz XULA700115
Solid state output Dark 20-264 V 20-60 V 500 mA 200 Hz XULA700215
DC – 6' (2 m) cable
3 wire PNP Light/dark – 10-30 V 200 mA 200 Hz XULH703535
3 wire NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ703535
Proximity Diffuse w/ Background Suppression – Sensing Range – 0.15' (0.3 m) ➀ a
AC/DC – 6' (2 m) cable
5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM300318
DC – 6' (2 m) cable
3 wire PNP Light/dark – 10-30 V 200 mA 200 Hz XULH303538➂
3 wire NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ303538➂
Proximity Diffuse w/ Adjustable Background Suppression: Sensing Range – 0.5 - 0.15 m a
DC – 6' (2 m) cable
3 wire PNP Light/dark – 12-24 Vdc 200 mA 200 Hz XULH153538
3 wire NPN Light/dark – 12-24 Vdc 200 mA 200 Hz XULJ153538
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ Fixed, no sensitivity adjustment.
➁ See p. 518 for matching connector cables.
➂ Supplied with potentiometer to adjust range between 15 and 30 cm.
k 20 < Vdc < 58 IEC 60947-5-2 Utilization category DC-13. Vdc > 58 IEC 60947-5-2 Utilization category DC-12.

104
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUL Sub-compact
DC, AC/DC
XUL SubCompact / DC, AC/DC

Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3 1
Temperature range -13° F to 140° F (-25° C to 60° C)
NEMA Type 1, 3, 4, 6, 6P, 12, 13
2 3 Enclosure rating
1 2 CENELEC Type IP67 conforming to IEC 60529 and IP671 conforming to NFC 20-010
Enclosure materials Housing: ABS/PC Lens: PMMA Cable: PVC
Vibration resistance 7 G, mm amplitude (f = 10 to 55 Hz)
DC AC/DC

Photoelectric Sensors
Shock resistance 20 G for 11 ms
Emitter Emitter Wiring 6' (2 m) cable, 0.2" OD, 4 x 22 AWG or 2 x 22 AWG
BN BN AC/D
Electrical DC Models Relay AC/DC Model solid state
BU BU AC/D Voltage range - 24-240 Vac/dc 24-240 Vac/dc
Leakage current 1.7 mA 1.5 mA 1.7 mA AC; 1.5 mA DC
Minimum load current 0 mA 0 mA 5 mA
DC Receivers 3 wire
Power Supply Current (no load) 30 mA 5 mA (emitter) 25 mA (all others)
Cable, PNP On delay max. 4 ms 25 ms 25 ms
BN
BK Off delay max. 4 ms 25 ms 25 ms
BU Power up delay max. 15 ms 60 ms 60 ms
Wavelength 880 nm 880 nm 880 nm
Select OG + light
- dark
Polarized 660 nm 660 nm 660 nm
Cable, NPN Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
BN DC 2 wire: IEC 61000-4-2, L3a (8 kV)
BK
Electrostatic discharges DC 3 wire: IEC 61000-4-2, L2a (4 kV)
BU Protective Circuitry
AC/DC: IEC 61000-4-2, L3a (8 kV)
+ light
Select OG
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
- dark
Connector, PNP Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
1 E164353 LR44087
4 Agency Listings CCN NKCR Class
®
3 3211 03

Not for Use on New


+ light
Select 2 a L indicates level number.
- dark
Connector, NPN Options
1

n s – L im it
4

e
3

d P ro d u c t Description
Micro style DC receptacle (DC models only) See p.518 for matching connector
Suffix Adder
D

Applicatio
+ light cables
Select 2 Micro style AC/DC receptacle (AC\DC models only) K
- dark 16' (5 m) cable L05
33' (10 m) cable L10

Availability
AC/DC Receivers:
Example: XUL 08014L10
Relay Solid state
BK
OG
AC/DC
- BN AC/DC
Accessories
RD
BN AC/DC BU AC/DC Description Catalog Number
BU
Mounting bracket (Included) XULZ41

Excess Gain Curves


Thru-beam Polarized reflex Reflex AC/DC Diffuse

gain gain gain gain

target 20x20 cm
500 50 white 90 %
50 10
30 30 7
25 25 RF 30
100
15 15 5
50 RF 30 Polarized 4
10 10
7 7 3
10
5 3 3 2

D (m) D (m) D (m) D (cm)


1 1 1 1
0.1 0.2 0.4 0.6 0.81 2 3 4 5 6 8 910 13 0,7 1 1,5 2 4 6 8 10 20 30 0.7 1 1.5 2 4 8 9 10 20 30 0 10 20 30 40 50 60 70 80

Diffuse system with adjustable background suppression XUL•15•••• Diffuse system with adjustable background suppression XUL•30••••
Potentiometer at minimum Potentiometer at maximum Potentiometer at minimum Potentiometer at maximum
B B B B A-B: Object reflection coefficient
A-B: Object reflection coefficient
Black 6% Black 6%
Grey 18% Grey 18%
White 90% White 90%
Sensing range Sensing range
Non detection zone Non detection zone
(Matt surfaces) (Matt surfaces)

A A
A 0.01 0.15 S (m) A 0.01 0.20 0.35 S (m) 0.01 0.07 S (m) 0.01 0.17 S (m)
0.10 0.20 0.30 0.05 0.15

Connector Cables
(M12 or D suffix; U20 or K suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCK101Y Mini Conn., 5 pin, 2 m, straight
XSZCK111Y Mini Conn., 5 pin, 2 m, 90° Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Page 166
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156
For additional cable options and lengths see p. 518 Sensing pattern. . . . . . . . . . . . . . . . . . . . . . Page 159

105
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJ L Compact Economy
AC/DC
XUJ L Compact Economy / AC/DC

Compact rectangular long range Economy self-contained photoelectric sensors for demanding
industrial application.
Features:
• Housings: high performance synthetic resin (ULTEM™) ➁
• Reduced condensation on the lenses at heat/cold changes
Photoelectric Sensors

• High excess gain to burn through air pollutants


• No adjustment (potentiometer) for case in troubleshooting
XUJ Thru-beam • 0.5" NPT conduit entrance is standard (metric version available)
and Retroreflective • FINGER GUARD™ isolated terminals in “ready to wire” position
• Mini style and micro style connectors available
• Flat lenses (except polarized)
• Corrosion proof
• Double insulated (no grounding required)
• Infrared modulated LED emission for a high ambient light immunity (visible red for polarized
models)
• AC/DC models with relay output
• Noise and transient protection
• LED output indicator (frontal)
XUJ Polarized
Retroreflective • 3 sensing modes are available: Thru-beam (separate Emitter-Receiver), Retroreflective
(reflector required), Polarized retroreflective (corner-cube reflector required)
• Light mode output function with N.O. and N.C. relay contacts
• “Universal” mounting bracket allows replacement of many competitive products in same
shape (XUZA49 included)
• UL Listed, CSA Certified, CE Mark
Voltage Range Load Operating
Output Catalog
Circuit Type Current Frequency
Mode AC max. DC max. Number
Max. k Max.
Thru-beam – 65.6' (20 m) Nominal Sensing Range a
XUZD09
Emitter AC/DC
Alignment Tool
– – 20-264 V 20-60 V – – XUJLM1503
Receiver AC/DC relay
N.O.+N.C. Light 20-264 V 20-60 V 2A 20 Hz XUJLM1514

Retroreflective – 33' (10 m) Nominal Sensing Range ➀ a (Reflector sold separately)


AC/DC relay
N.O.+N.C. Light 20-264 V 20-60 V 2A 20 Hz XUJLM0811

Polarized Retroreflective – 24' (7.3 m) Nominal Sensing Range ➀ a (Reflector sold separately)
AC/DC relay
N.O.+N.C. Light 20-264 V 20-60 V 2A 20 Hz XUJLM0619
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ Range when used with RF30 or XUZC50 reflector.
➁ ULTEM is a GE plastics trademark.
k 20 ≤ Vdc ≤ 58 IEC 60947-5-2 Utilization category DC-13
Vdc ≥ 58 IEC 60947-5-2 Utilization category DC-12

106
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUJ L Compact Economy
AC/DC
XUJ L Compact Economy / AC/DC

Wiring Specifications
Mechanical
Connector
3 For usable sensing range, see excess gain curve charts
1 3
4 2 Temperature range -13° F to +131° F (-25° C to +55° C)

2 5 1 NEMA Type 1, 3, 6, 12, 13


Enclosure rating
IEC Type IP67 conforming to IEC 60529 and IP671 conforming to NFC 20-010
Switch is shown in de-energized state. Vibration resistance 7 G, 1.5 mm amplitude f= 10 Hz to 55 Hz

Photoelectric Sensors
Light mode: output is energized when Shock resistance 30 G, for 11 ms
target is not present Wiring - screw terminals #16 AWG
Electrical
Power supply current (no load) (max.) 30 mA
1 L1/– Relay contract voltage rating (max.) 250 Vac
2
L2/+ On delay (max.) 25 ms
5 Off delay (max.) 25 ms
4 Power up delay (max.) 60 ms
3
880 nm
Wavelength
5 Wire Relay AC/DC Polarized 660 nm
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
Electrostatic discharges AC/DC: IEC 61000-4-2, L3a (8 kV)
Protective Circuitry Fast transients (motor start/stop
1 IEC 61000-4-4, L3a (1 kV)
L1/– interference)
Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
2
L2/+ E164353 LR44087
Agency Listings CCN NKCR Class 3211 03
®

Emitter
a L indicates level number.

Options
Description Matching Connector Cables Suffix
Metric cable entry PG9 P9
Receptacle mini style 5 pin - AC/DC models XSZCA1501Y R5
Receptacle mini style 3 pin - N.O. output XSZCA901Y R30
Receptacle mini style 3 pin - N.C. output XSZCA901Y R31
For additional cable options and lengths see p. 518

Accessories
Description Catalog Number
Protective Cover - bottom entry, metric XUJZ09
Alignment tool XUZD09
“Universal” mounting bracket (included) XUZA49
Thru-beam aperture 0.11" (3 mm), sensing distance 39.4" (1 m) XUJZ02
Thru-beam aperture 5 mm dia. (1 m sensing) XUZ202

Excess gain curves


Thru-beam Retroreflective * Polarized Retroreflective
(Temp: 25°C) (Temp: 25°C) (Temp: 25°C)
gain gain gain
1000 1000 1000
500 500

100 100 100


500 50 50

10 10 10
50 5 5

1 1 1
50.1 0.2 0.4 1 2 4 10 1520 0.1 0.2 0.4 1 2 4 8 10 0.1 0.2 0.4 1 2 4 6 10
D (m) D (m) D (m)
* with reflector RF30

Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . Page 166


Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156
Beam patterns . . . . . . . . . . . . . . . . . . . . . . Page 162

107
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJ Compact Universal
DC, AC/DC
XUJ Compact Universal / DC, AC/DC

Compact rectangular long range self contained photoelectric sensors for demanding industrial application.
Features:
• Housings: high performance synthetic • Marginal Detection Signal (MDS) test
resin (ULTEM™) ➂ output for DC models
• Reduced condensation on the lenses at heat/cold • AC/DC models available with separate
changes (independent) ON and OFF delay timer
Photoelectric Sensors

• 0.5" NPT conduit entrance is standard (metric • Reverse polarity protection for DC models
version available) • Noise and transient protection
• FINGER GUARD™ isolated terminals in “ready- • Short circuit protection (SCP) standard for DC
to-wire” position models
Alignment Operation
• Double insulated (no grounding required) • 2 LED alignment system with 360° visibility
• Adjustments protected by optional cover • Light/Dark selectable (by wiring) output function
E • Infrared modulated LED emission for a high • Sensitivity adjustment and mounting bracket
ambient light immunity (visible red for polarized allows easy alignment in 2 planes (included)
models) • Analog proximity diffuse available: Page 110.
On

Correct alignment – LED Off

D On
Off

– LED

• DC complementary PNP/NPN; AC/DC models


Off
ent – LE
ED

ED

with relay output


t–L

ent

–L
l alignm
men

l alignm

nt

Voltage Range Load Operating


me

Circuit Output Catalog


n

lign

Current frequency SCP


g
t ali

Type Mode AC max. DC max. Number


a

Margina

ct a
Margin

Max. Max.
rrec

orre
Inco

Thru-beam – 42.6' (13 m) Nominal Sensing Range a


Inc

Emitter AC/DC
– – 20-264 V 20-60 V – – – XUJM1000
R
Receiver DC
RED LED off
PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK103534
RED LED on Receiver AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM100314
Receiver AC/DC relay with timer (.25s to 15s)
Test Output N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT100314
Retroreflective – 29.5' (9 m) Nominal Sensing Range ➀ a (Reflector sold separately)
Red LED
MDS DC model
t t
output PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK06353
signal AC/DC relay
State 0 : output connected to -
State 1 : output connected to + N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM06031
t = 160 ms* AC/DC relay with timer (.25s to 15s)
* time delay to avoid nuisance signals N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT06031
Polarized Retroreflective – 26.2' (8 m) Sensing Range ➀ a (Reflector sold separately)
DC model
PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK063539
AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM060319
AC/DC relay with timer (.25s to 15s)
N.O.+N.C. Light/Dark 20-264 Vac 20-60 V 2A 20 Hz No XUJT060319
Proximity (Diffuse) w/ Background Suppression – 27" (70 cm) Sensing Range ➁ ➃ a
DC model
PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK703538
AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM700318
AC/DC relay with timer (.25s to 15s)
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT700318
Proximity (Diffuse) w/ Background Suppression – 48" (1.2 m) Sensing Range ➁ ➃ a
XUZD09 DC model
Alignment Tool PNP/NPN Light/Dark 10-38 V 200 mA 200 Hz Yes XUJK123538
AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM120318
AC/DC relay with timer (.25s to 15s)
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT120318
a Excess gain one - in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ Range when used with RF30 reflector.
➁ With white 90% Kodac 20 x 20 cm (8" x 8")paper.
➂ ULTEM is a GE plastics trademark.
➃ Analog Proximity (diffuse) with background suppression - see page 110.

108
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUJ Compact Universal
DC, AC/DC
XUJ Compact Universal / DC, AC/DC

Wiring Specifications
Mechanical
Emitter For usable sensing range, see excess gain curve charts
1 Temperature range -13° F to 140° F (-25° C to 60° C)
NEMA Type 1,3,6,12,13
3 Enclosure rating IP67 conforming to IEC 60529 and IP671 conforming to NFC 20-
IEC Type
010, double insulated
Test Output (thru-beam & reflex) Vibration resistance 7 G, 1.5 mm amplitude, f=10 Hz to 55 Hz
2/3 Shock resistance 30 G, for 11 ms

Photoelectric Sensors
NPN Wiring - screw terminals #16 AWG
6 PNP
Electrical AC models DC models
1
Voltage drop across switch (max.) 0 1.5 V
Light switching (no object present) Power supply current (no load) (max.) 45 mA 30 mA
Thru-beam receiver & reflex Relay contract voltage rating (max.) 250 Vac –
On delay (max.) 25 ms 2 ms
PNP output
Off delay (max.) 25 ms 2 ms
3
Power up delay (max.) 60 ms 15 ms
5 880 nm 880 nm
Wavelength
1 Polarized 660 nm 660 nm
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V per meter)
NPN output
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
3
Electrostatic discharges DC 3 wire: IEC 61000-4-2, L2a (4 kV)
4
Protective Circuitry AC/DC: IEC 61000-4-2, L3a (8 kV)
1 Fast transients (motor start/stop
IEC 61000-4-4, L3a (1 kV)
interference)
Diffuse Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
PNP output E164353 LR44087
2 Agency Listings CCN NKCR Class 3211 03
®

5
a L indicates level number.
1
NPN output Options
2 Description Matching Connector Cables Suffix
4 Metric cable entry PG9 P9
1 Receptacle micro style DC XSZCD101Y D1
Receptacle micro style DC - bottom XSZCD101Y D2
Receptacle mini style 5 pin - AC/DC models XSZCA1501Y R5
Dark switching (no object present) Receptacle mini style 3 pin AC or AC/DC modelst XSZCA901Y R3
Thru-beam receiver & reflex
For additional cable options and lengths see p. 518
PNP output
t NPN output, dark – standard. For other configurations contact plant.
2
5 Accessories
1 Description Catalog Number
NPN output Alignment tool XUZD09
2 Protective cover (top) XUJZ01
4 Mounting bracket (included) XUZA41
Thru-beam aperture 0.11" (3mm), sensing distance 39.4" (1m) XUJZ02
1

Diffuse
Excess Gain Curves
PNP output
3 Thru-beam (Temp : 25°C) Infrared reflex (Temp : 25 °C) Polarized reflex (Temp : 25 °C)

5 gain gain
1 500

NPN output
40 40
3 100
30 30
4 50 20 20

1 10 10
10
5 5
Terminal connections 5
Solid state output
D (m) RF 30 D (m) RF 30 D (m)
1 — (-)
1 1 1
2 — (+) 0.1 0.2 0.4 0.6 0.8 1 2 3 456 10 15 20 0.1 0.2 0.4 0.60.8 1 2 3 4 5 6 910 0.1 0.2 0.4 0.6 0.81 2 3 4 5 6 7 910

3 — (+) Dark switching (1) Background Suppression: 70 cm


4 — NPN
Potentiometer at the minimum Potentiometer at the maximum
5 — PNP target target
B
6 — TEST color B
color
(1) (+) light and dark are BLACK BLACK
6% 6%
non-
reversed for diffuse systems non-detection detection
GREY zone GREY zone
18% Sensing 18% Sensing
range range
WHITE WHITE
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . Page 166 90% A 90% A
0.05 0.35 0.4 0.5 sensing distance (m) 0.05 0.6 0.7 0.8 sensing distance (m)
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156
Beam patterns . . . . . . . . . . . . . . . . . . . . . . Page 162

109
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJ Analog with Background Suppression
Analog Output — DC
XUJ Analog with Background Suppression / Analog Out - DC

2.40 Features:
61 LED
• Distance indication (measurement) that is independent of target color or texture.
• Elimination of background influence.
• Dual outputs 4-20 mA and 0-10 Vdc (Selectable).
.10
• Long range proximity (Diffuse) with background suppression 20-80 cm (7.87" - 31.50").
2.6
Photoelectric Sensors

• FDA approved housing material – ULTEM™ Plastic.


A • Industrial environmentally rated for resistance to shock, vibration and aggressive industrial
environments (i.e. water, salts, oils, grease, alcohols and cleaning solutions.)
1.18
30

• Seamless housing design.


1.20
30.5

• LED indicator which gives an illumination level proportional to the output voltage.
.66
17

• No grounding required – double insulated enclosure.


10° 10°

.39 .78
• UL Listed, CSA Certified, CE Mark
.35
10 20 9 3.29
83.6
Applications:
A : 1/2" NPT • Bulk or liquid level control.
B : 1 elongated hole Ø 4.2 x 14
• Thickness monitoring.
• Winder speed control.
• Position indication for feedback to drives and similar devices in web control applications.
1.07 • Size sorting such as fruit and vegetables.
1.35
.05

27.2

Circuit Output Voltage Current Voltage Catalog


≤ Type Mode Range Output Output Number
Proximity (diffuse) With Background Suppression 7.87" - 31.5" (20 - 80 cm)
R
3.34

Analog type Light 20-30 Vdc 4-20 mA 0-10 V XUJK803538


85
.51

13

E
1.18*
30

98.85
3.89
2.46
62.5

10 10

1.28
32.6

* Front mounting
(Ø 4 screws and inserts supplied)

Dual Dimensions inches


mm

110
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUJ Analog with Background Suppression
Analog Output — DC
XUJ Analog with Background Suppression / Analog Output - DC

Wiring Specifications
Connector Mechanical
3 Temperature range -13° F to 140° F (-25° C to 60° C)
4 2 NEMA Type 1,3,6,12,13
Enclosure rating IP67 conforming to IEC 60529 and IP671
5 1 IEC Type
conforming to NFC 20-010, double insulated
Vibration 7G, 1.5 mm amplitude, f =10 Hz to 55 Hz

Photoelectric Sensors
1 – (-) Comm. Shock resistance 30G for 11 ms
Wiring – screw terminals #16 AWG
2 –
Electrical
Voltage limit (including ripple) 20-30 Vdc
3 – (+) 24 Vdc
Power supply current (no load) 40 mA
4 – Vs Operating frequency maximum 50 Hz
Voltage output 0-10 Vdc
5 – Is Current output 15 mA
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
6 – (-) Com. DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
Note: Terminals 1 and 6 are
internally connected. Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E164353 LR44087
Agency Listings CCN NKCR Class 3211 03
®

a L indicates level number.

Options
Description Matching Connector Cables Suffix Adder
Receptacle mini style 5 pin XSZCA1501Y R5
For additional cable options and lengths see p. 518

Accessories
Catalog
Description
Number
Protective cover (top) XUJZ01
Mounting bracket (included) XUZA41

Output Across Load


Vs mA Is

10V 20

OV
15 20 80 D (cm) 15 20 80 D (cm)

Current Output (Is)


Voltage output (Vs)
according to distance
according to distance
1
1
2
2
3
3
R LOAD> 1 k 4
4
5
R LOAD< 1 k
5
6
6

Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . Page 166


Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156
Beam patterns . . . . . . . . . . . . . . . . . . . . . . Page 162
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . Page 517

111
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUE Long Range, Plug In
AC/DC, DC
XUE Long Range, Plug In / AC/DC, DC

Plug-in rectangular long range self contained photoelectric sensors for demanding industrial
applications.
Features:
• Housing: epoxy filled plastic (thermoplastic • AC/DC models available with programmable
polyester) timers
• Selected models are offered in low • Reverse polarity protection for DC models
Photoelectric Sensors

temperature (-40°F) version • Noise and transient protection


• 0.5" NPT conduit entrance is standard • Short circuit protection (SCP) standard for
(Metric version available) DC and solid state output AC/DC models
• FINGER GUARD™ isolated wiring • 2 LED alignment system
terminals in “ready-to-wire” position
• LED output indication
• Captive gaskets
• Light/Dark selectable output function
• Flat lenses
• Sensitivity adjustment
• Corrosion proof
• Mounting bracket allows easy alignment in 2
• Double insulated (no grounding required) planes (included)
• Adjustments protected by top cover • Glass fiber optic amplifier (see Page 118)
• Infrared modulated LED for high ambient • UL Listed and CSA Certified.
immunity (visible red for polarized models)
• Complimentary PNP/NPN; AC/DC models
XUZD09 with relay or solid state outputs
Alignment Tool Voltage range Load Operating
Circuit Catalog
Current Frequency SCP
Type AC max. DC max. Number
Max. k Max.
Thru-beam – 203' (62 m) Nominal Sensing Range a
Emitter AC/DC
2 wire 20-264 V 10-58 V – – – XUEH3000
Receiver DC
PNP/NPN – 10-58 V 200 mA 300 Hz Yes XUEH307534
Receiver AC/DC, relay output
N.O.+N.C. 20-264 V 20-58 V 2A➃ 30 Hz No XUEF300314
Receiver AC/DC with timer (.03-60 sec), relay output
N.O.+N.C. 20-264 Vac 20-58 V 2A➃ 30 Hz No XUET300314
Retroreflective – 41' (12.5 m) Nominal Sensing Range ➀ a (Reflector sold separately)
DC model
PNP/NPN – 10-58 V 200 mA 300 Hz Yes XUEH10753
AC/DC models, relay output
N.O.+N.C. 20-264 V 20-58 V 2A➃ 30 Hz No XUEF10031
AC/DC solid state output
2 wire 20-264 V 20-58 V 350 mA ➃➅ 25 Hz Yes XUEA10053
AC/DC with timer (.03-60 sec), relay output
N.O.+N.C. 20-264 V 20-58 V 2A➃ 30 Hz No XUET10031
Polarized Retroreflective – 33' (10 m) Nominal Sensing Range ➀
a (Reflector sold separately)
AC/DC model, relay output
a Excess gain one – in normal ambient
conditions, maximum usable sensing N.O.+N.C. 20-264 V 10-58 V 2A➃ 30 Hz No XUEF080319
distance is 75% of normal. AC/DC with timer (.03-60 sec), relay output
➀ Range when used with reflector RF30. For N.O.+N.C. 20-264 V 10-58 V 2A➃ 30 Hz No XUET080319
other reflectors see Page 156.
Proximity (diffuse) – 6.6' (2 m) Nominal Sensing Range ➁ a
➁ With 90% white Kodak paper 20x20 cm
(8"x 8"). DC model
➃ Max. 240 Vac rating. 100mA DC PNP/NPN – 10-58 V 200 mA 300 Hz Yes XUEH017535
➅ 1.7mA leakage - Programmable control AC/DC model, relay output
compatible. N.O.+N.C. 20-264 V 20-58 V 2A➃ 30 Hz No XUEF010315
k 20 ≤ Vdc ≤ 58 IEC 60947-5-2 Utilization
AC/DC model with timer (.03-60 sec), relay output
category DC-13
N.O.+N.C. 20-264 V 20-58 V 2A➃ 30 Hz No XUET010315
Vdc ≥ 58 IEC 60947-5-2 Utilization category
DC-12. DC Models With Background Suppression – 20 cm to 6.6' (0.2 to 2 m) a
PNP/NPN – 10-30 V 20 mA 100 Hz Yes XUEH753538

112
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUE Long Range, Plug In
AC/DC, DC
XUE Long Range, Plug In / AC/DC, DC

Wiring Specifications
Connector Mechanical AC Models DC Model
1 3 3 For usable sensing range, see excess gain curve charts
4 2 -13° F to 158° F (-25° C to 70°
Temperature range -13° F to 131° F (-25° C to 55° C)
C)
2 5 1
NEMA Type 1, 3, 4, 13 1, 3, 4, 13
Enclosure rating IP67 conforming to IEC 60529 and IP673 conforming to NFC 20-
IEC Type IP67
010
DC Emitter
AC/DC emitter

Photoelectric Sensors
L1 L2 Vibration resistance 7 G @ 0.6 mm Amplitude 7 G @ 0.6 mm Amplitude
Brown XUEH and XUEA 30 G for 11 ms 10 G for 11 ms
A1 Shock resistance
XUEF and XUET 20 G for 11 ms
Blue Electrical
A2
5mA (XUEA);
Minimum switching current
15mA for relay output
Thru-Beam Reflex/Prox Thru-Beam Reflex/Prox Background
Power supply current (no load) 45 mA 35mA
XUEA… On delay (max) 25 ms 25 ms 2.5ms 1.5ms 8ms
2 wire AC/DC Off delay (max) 30 ms 30 ms 2ms 1ms 8ms
L1 L2
Power up delay 120 ms 80 ms 70ms 27ms 30ms
A1 Wavelength 880 nm 880 nm 880nm 880nm 880nm
LOAD Polarized – 660 nm – 660nm –
A2 Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Protective Circuitry
AC/DC: IEC 61000-4-2, L3a (8 kV)
XUEH… Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
H NPN - Sinking Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
N E164353 LR44087
Agency Listings CCN NKCR Class 3211 03
LOAD ®

- - a L3 indicates level number.


+ +
Options
Description Matching Connector Cables Suffix
XUEJ… Receptacle mini style 3 pint (DC and 2 wire AC/DC models) XSZCA901Y R3
H PNP - Sourcing Receptacle mini style 5 pin (Relay output models) XSZCA1501Y R5
Metric threaded cable entry Metric
P LOAD For additional cable options and lengths see p. 518
- - Example: XUEF10031 R5
+ + t PNP, N.O. for DC and N.O. for AC. Light mode. Standard. For other configurations or connector types contact Square D Company
.

Accessories
XUEF… Description Suffix Min. Quantity
A1
Mounting bracket (included) XUZA44 1
F L1
12 Glass lens cover and sun shade XUZD02 1
N/C
11 Alignment tool XUZD09 1
COMMON
13 Fuse 0.8A fast blow – for XUEA XUZE08 10
N/O
A2 L2
De-Energized
Timing Features
XUET models (including the fiber optic model) feature a sophisticated timing circuit (0.03-60 sec.) which can be programmed via the
selector switches located under the top cover. In conjunction with the light-dark switch, the following functions can be implemented:
XUET…
A1 L1
T
16 N/C
15
COMMON Alignment
18
N/O LED's
ON Delay - on beam reception Sensitivity
A2 L2
De-Energized - on beam interruption On/Off adjustment
OFF Delay - on beam reception LED
- on beam interruption Light/Dark
Monostable (one shot) selector Timing
- on beam reception switch adjustment
- on beam interruption
Timer
selector
switches
(XUET only)

Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . Page 167


Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . Page 156
Beam patterns . . . . . . . . . . . . . . . . . . . . . . Page 162

113
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUE Long Range, Plug-In
AC/DC, DC
XUE Long Range, Plug-In / AC/DC, DC

Thru-beam Emitter + 2 Wire AC/DC Solid State Retroreflective


Description Catalog Number
Wiring receptacle, 0.5" NPT cable entry ZUEZ04H7
Wiring receptacle, metric (CM12) cable entry ZUEZ04
Switch body emitter ZUEH3000H7
Retroreflective solid state switch body ZUEA10053
Photoelectric Sensors

Relay Output Sensors


Description Catalog Number
Switch Body
Wiring receptacle, 0.5" NPT cable entry ZUEZ02H7
Wiring receptacle, Metric (CM12) cable entry ZUEZ02
Switch body proximity, AC/DC ZUEF010315H7
Switch body polarized retroreflective AC/DC ZUEF080319
Switch body retroreflective, AC/DC ZUEF10031H7
Switch body thru-beam receiver, AC/DC ZUEF300314H7

DC Output Sensors
Description Catalog Number
Wiring receptacle, 0.5" NPT cable entry ZUEZ03H7
Wiring Receptacle Wiring receptacle, metric (CM12) cable entry ZUEZ03
Switch body proximity, PNP/NPN ZUEH017535H7
Switch body retroreflective, PNP/NPN ZUEH10753H7
Switch body proximity with background suppression PNP/NPN ZUEH753538
Switch body thru-beam receiver PNP/NPN ZUEHB07534

Programming time delay output

(F1)
<t
Time delay on breaking of the beam:
(F2)
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2)
C4 t t t 0: relay de-energized 1: relay energized
C5
C6 0 Dark switching with output delay,
duration: 1 Receiver light: on
1
thru-beam and
t t t t
Dark switching with monostable (one shot) reflex system
0 period, duration: 1 detectors the light
beam is intact (no
1 Light switching with output delay, target present);
t t t duration: 1 on diffuse system
detectors light is
0 being reflected
Light switching with monostable (one shot)
1 period, duration: 1 back to the
t t t t receiver from the
target (target
0 present).

Receiver dark: on
(F1)
thru-beam and
<t reflex system
Time delay on breaking of the beam: detectors the light
(F2) beam is broken
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2) (target present);
C4 t t t 0: relay de-energized 1: relay energized on diffuse system
C5 detectors light is
C6 0 Dark switching with output delay, not being
1
duration: 1 reflected back to
t t t t the receiver from
Dark switching with monostable (one shot) the target (no
0 period, duration: 1 target present).

1 Light switching with output delay,


t t t duration: 1
0 Light switching with monostable (one shot)
1 period, duration: 1
t t t t

114
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUE Long Range, Plug-in
Replacement Parts
XUE Long Range, Plug-In / Replacement Parts

Relay Output With Timer


Description Catalog Number
Wiring receptacle, 0.5" NPT cable entry ZUEZ05H7
Wiring receptacle, Metric (CMR) cable entry ZUEZ05
Switch Body Proximity AC/DC ZUET010315H7
Switch Body Retroreflective AC/DC ZUET10031H7
Switch Body Polarized retroreflective AC/DC ZUET080319

Photoelectric Sensors
Switch Body Receiver AC/DC ZUET300314

AC/DC Solid State Output


Description Catalog Number
Wiring receptacle, 0.5" NPT cable entry ZUEZ01H7
Wiring receptacle, Metric (CM12) cable entry ZUEZ01
Switch Body Retroreflective ZUEA10053H7

Excess Gain Curves


Thru-beam (Temp : 25 °C) Infrared reflex (Temp : 25 °C)
gain gain
100

2000
1000 50

400 XUZC24
20

100
10
70
7

10
RF 30
3
D (m)
D (m)
1 1
0.8 1 2 4 6 8 10 20 30 4050 100 0.1 0.2 0.4 0.6 0,8 1 2 3 5 7 910 15

Polarized reflex (Temp : 25 °C) Diffuse (Temp : 25 °C)


gain gain
100 50

50 30
target 20 x 20 cm
20
20 white 90 %
RF 30 10
10
7
7
5
3 3

D (m) D (m)
1 1
0.1 0.2 0.4 0.6 0.8 1 2 3 5 7 8 10 15 0.05 0.08 0.1 0.2 0.4 0.6 0.8 1 1.5 2 2.5

115
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFA Glass Fiber Optics and Amplifiers
Description, Selection
XUFA Glass Fiber Optics and Amplifiers / Description, Selection

.281" (7.1) The XUFA is one of the most versatile heavy duty glass core fiber optics in stainless steel
.187" (4.7)
sheetings available.
.125" (3.1)

Features:
Smooth, straight
• Coiled stainless steel sheathing withstands most aggressive environments while
maintaining a high degree of flexibility
• Transmission of light through the fiber optics is not affected by water, gasoline, oil, sulfuric
Photoelectric Sensors

1.5" (38.1)
.125" (3.1)
acid or other organic acids
Threaded, straight • Most common sensing tips are standard (Other tip configurations and cable lengths can be
1.1"
made on order - contact factory)
.281" (7.1)
28
• Very high temperature range -49° F to 527° F (-45° C to 275° C)
.8" (20.3)
• Two scanning modes are recommended: Thru-beam using a pair of cables (emitter-
Smooth, 90 .187" (4.7) receiver)
.125" (3.1)
• Proximity (diffuse) using a bifurcated cable with a triple sensing tip in which emitter and
28
.281" (7.1)
1.1" receiver fibers are mixed.
Note: With some precautions to avoid the proximity effect, the bifurcated cable can also be
.8" (20.3)
used in retroreflective scanning mode.
5/16-24
1.5" (38.1)
• AC/DC relay output, XUE model with timer
Threaded 90 • Selectable Light/Dark
.125" (3.1)

Nominal Sensing Distance a Catalog


1.00" Tip Length Max. Bundle Diameter
25.4 .032" (0.8) XUET Number
.281"(7.1)

.75"(19)
Thru-beam (pair) (single emitter and receiver sold as a pair)
.46 (11.7)
Smooth, straight 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110213
.75"
19 Threaded, straight 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110113
.25" (6.3)
Window, short Threaded, straight 11.8" (30 cm) 12' (3.66 m) 0.125" (3.2 mm) XUFA1101112
Smooth, 90 ° 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110413
Threaded, 90 ° 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110313
Window, short 10" (25.5 cm) 36" (91.4 cm) 0.38" x 0.032" (9.65 mm x 0.81mm) XUFA110513
Proximity (bifurcated) (Y-shaped dual reflective type)
Smooth, straight 4.33" (11 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210213
Threaded, straight 5.51" (14 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210113
Threaded, straight 4.53" (11.5 cm) 12' (3.66 m) 0.125" (3.2 mm) XUFA2101112
Smooth, 90 ° 3.94" (10 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210413
Threaded, 90 ° 4.72" (12 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210313
Window, short 3.94" (10 cm) 36" (91.4 cm) 0.38" x 0.032" (9.65 mm x 0.81mm) XUFA210513
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.

116
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFA Glass Fiber Optics
Specifications
XUFA Glass Fiber Optics / Specifications

Wiring Amplifier Specifications


Light mode output is energized when target Mechanical
is not present (proximity output is energized Temperature range -13° F to 158° F (-25° C to 70° C)
when target is detected).
NEMA Type 1
Dark mode output is energized when target Enclosure rating (XUET)
IEC Type IP400
is present (proximity output is energized
Shock resistance 20 G for 11 ms
when target is not detected).
Vibration 7G @ .6 mm amplitude

Photoelectric Sensors
Cable Screw terminals #16 AWG
XUET1401266
Electrical
A1 L1 Power supply current 45 mA
16
N/C Voltage drop across switch –
15
COMMON On delay 25 ms
18
N/O
A2 Off delay 30 ms
De-Energized L2
Power up delay 80 ms
Wavelength 880 nm
E164343 LR60942
Agency Listings CCN NKCR Class 4812 05
®

a L indicates level number.

Accessories
Description Magnification factor (thru-beam) t Catalog Number
XUFAZ01 Lenses (pair) for threaded tips X10 XUFAZ01
Lenses (pair) for smooth tips X10 XUFAZ02
t Will improve range approximately 3 to 5 times

XUFAZ02

117
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUE Amplifier for XUFA Glass Fiber Optics
XUE Amplifiers for XUFA Glass Fiber Optics

Self-contained Amplifier
Circuit Type Output Mode Voltage Range Max. Load Current Max. Operating Frequency Catalog Number
N.O.+N.C. Light/Dark 20 - 264 Vac/dc 2A 20 Hz XUET1401266
See page 167 for dimensions

Timing Features
The XUE T model features a sophisticated timing circuit (.03-60 sec.) which
Photoelectric Sensors

can be programmed via the selector switches located under the top cover.
Alignment
In conjunction with the light/dark switch, the following functions can be
LED's
implemented. Sensitivity
on beam reception On/Off adjustment
ON delay:
on beam interruption LED
on beam reception Light/Dark
OFF delay: selector
XUET on beam interruption Timing
switch adjustment

(one shot) Timer


Monostable on beam reception selector
on beam interruption switches
(XUET only)

Programming time delay output

(F1)
<t
Time delay on breaking of the beam:
(F2)
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2)
C4 t t t 0: relay de-energized 1: relay energized
C5
C6 0 Dark switching with output delay,
duration: 1 Receiver light: on
1
thru-beam and
t t t t
Dark switching with monostable (one shot) reflex system
0 period, duration: 1 detectors the light
beam is intact (no
1 Light switching with output delay, target present);
t t t duration: 1 on diffuse system
detectors light is
0 being reflected
Light switching with monostable (one shot)
1 period, duration: 1 back to the
t t t t receiver from the
target (target
0 present).

Receiver dark: on
(F1)
thru-beam and
<t reflex system
Time delay on breaking of the beam: detectors the light
(F2) beam is broken
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2) (target present);
C4 t t t 0: relay de-energized 1: relay energized on diffuse system
C5 detectors light is
C6 0 Dark switching with output delay, not being
1
duration: 1 reflected back to
t t t t the receiver from
Dark switching with monostable (one shot) the target (no
0 period, duration: 1 target present).

1 Light switching with output delay,


t t t duration: 1
0 Light switching with monostable (one shot)
1 period, duration: 1
t t t t

118
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUET Amplifier Specifications
XUET Amplifier Specifications

Wiring Specifications
XUET… Mechanical XUET
Operating -13° to 158° F (-25° to 70° C)
A1 L1 Temperature range
T Storage -13° to 158° F (-25° to 70° C)
16 N/C
15 NEMA Type 1
COMMON Enclosure Rating IP40 conforming to IEC 60529 and IP400 conforming to NFC
18
N/O IEC Type
20-101 with fibers connected
A2 L2
De-Energized Vibration resistance 7 G @ 0.6 mm amplitude

Photoelectric Sensors
Shock resistance 20 G for 11 ms
Electrical
Voltage Range 20 - 264 Vac/dc
Voltage Drop (Across Switch)
N/A
Closed State max.
Leakage Current N/A
Max Load Current 2A
Current Consumption -- No Load 45 mA max.
On delay max. 25 ms
Off Delay Max. 30 ms
Reverse Polarity Protection N/A
False Pulse Protection Yes
Line Transients No

Accessories For XUFA Glass Fiber Optics Only


Description Catalog Number
Lenses (pair) for threaded tips (x10 Magnification Thru-beam) XUFAZ01
Lenses (pair) for smooth tips (x10 Magnification Thru-beam) XUFAZ01

Excess Gain Curves


Thru-beam (Temp : 25 °C) Infrared reflex (Temp : 25 °C)
gain gain
100

2000
1000 50

400 XUZC24
20

100
10
70
7

10
RF 30
3
D (m)
D (m)
1 1
0.8 1 2 4 6 8 10 20 30 4050 100 0.1 0.2 0.4 0.6 0,8 1 2 3 5 7 910 15

Polarized reflex (Temp : 25 °C) Diffuse (Temp : 25 °C)


gain gain
100 50

50 30
target 20 x 20 cm
20
20 white 90 %
RF 30 10
10
7
7
5
3 3

D (m) D (m)
1 1
0.1 0.2 0.4 0.6 0.8 1 2 3 5 7 8 10 15 0.05 0.08 0.1 0.2 0.4 0.6 0.8 1 1.5 2 2.5

119
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN Plastic and XUFS Glass Fiber Optics
XUFN Plastic and XUFS Glass Fiber Optics

Features
XUFN series of plastic core fiber optics provides flexibility in usage at an affordable price.
Threaded
• Smooth plastic jacket (polyethylene) in • Standard separate emitter-receiver bundles
straight or coiled versions, withstands most or randomized receiver with an emitter core
3.5" Flexible nozzle
industrial environments including food for very near detection are available. Note:
processing and pharmaceuticals with some precautions to avoid the proximity
Photoelectric Sensors

• Straight cable standard effect, the bifurcated cable can also be used
in retroreflective scanning mode
• Threaded and flexible nozzle tips
• XUFS series of glass core fiber optics
• Suitable for very small part detection
provides raggedness, higher temperature
Coiled cable
• Two scanning modes are recommended ratings and excellent withstanding in
• Thru-beam using a pair of cables (emitter- aggressive/chemical environments
receiver), Proximity (diffuse) using a • Coiled fiber cable for applications with
bifurcated cable with a single sensing tip in significant movement between the amplifier
which emitter and receiver fibers are mixed and the sensing tip
Plastic Fiber Optics
Flexible nozzle, coiled cable Sensing distance, Sn a Beam Cable Catalog
Tip
(max.) standard w/XUFZ01 lenses Diameter Diameter (OD) Number
Thru-beam (pairs) – 6.6' (2 m) long (single emitter and receiver sold as a pair)
Straight cable
Threaded 9.84" (250 mm) 73.68" (1.87 m) 0.04" (1 mm) 0.09" (2.2 mm) XUFN12301a
.6" Flexible nozzle 33’ (10 m) Threaded 4.43" (113 mm) 44.30" (1.13 m) 0.04" (1 mm) 0.09" (2.2 mm) XUFN12301L10a
Threaded 2.46" (62 mm) 19.68" (0.5 m) 0.02" (0.5 mm) 0.04" (1 mm) XUFN35301
3.5" Flexible nozzle 8.85" (225 mm) – 0.04" (1 mm) 0.09" (2.2 mm) XUFN12311
3.5" Flexible nozzle 2.48" (63 mm) – 0.02" (0.5 mm) 0.04" (1 mm) XUFN35311
Coiled cable
Threaded 7.30" (185 mm) 49.2" (1.2 m) 0.04" (1 mm) 0.09" (2.2 mm) XUFN10302
Direct plug 3.5" Flexible nozzle 7.30" (185 mm) – 0.04" (1 mm) 0.09" (2.2 mm) XUFN10312

Beam Cable Catalog


Tip Sensing distance, Sn a
Diameter Diameter (OD) Number
Proximity/diffuse (bifurcated) – 6.6' (2 m) long (Y-shaped dual reflective type)
Straight cable
Threaded➀ 3.44" (87 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN05321a
33’ (10 m) Threaded ➀ 1.96" (50 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN05321L10
0.04" (1 mm)+ 16 x 0.01"
Threaded➁ 3.44" (87 mm) 0.09" (2.2 mm) XUFN05323
(0.265 mm)
Threaded➀ 0.89" (23 mm) 2 x 0.02" (0.5 mm) 0.04" (1 mm) XUFN01321
0.02" (0.5 mm)+ 4 x
Threaded➁ 1.47" (38 mm) 0.04" (1 mm) XUFN02323
0.01" (0.25 mm)
M0.24
6 3.5" Flexible nozzle 3.44" (87 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN05331
1.28
32.5

3.5" Flexible nozzle 0.89" (23 mm) 2 x 0.02" (0.5 mm) 0.04" (1 mm) XUFN01331
Ø0.15 0.6" Flexible nozzle 0.30" (7.5 mm) 2 x 0.01" (0.265 mm) 0.04" (1 mm) XUFN04331
13
Coiled cable
Ø0.2 Threaded 1.00" (25 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN15322
5
3.5" Flexible nozzle 1.00" (25 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN15332
38.2970

Direct plug
M0.1 (2.6) 0.02" (0.5 mm)+ 8 x
3.5" Flexible nozzle 1.48" (37 mm) 0.06" (1.5 mm) XUDZ01
M4 0.01" (0.265 mm)
1.0
25

➀ Not recommended for very short sensing distances under 0.2" (5 mm) (coherent).
➁ Recommended for very short sensing distances (randomized).
Ø0.16
38.2
970

a Sensing distances change when used with ZUCN0016, ZUCN0017 and XUET1401266 amplifiers. Contact Square D for information and
5
beam patterns.
Glass Fiber Optics
Ø0.08 Ø0.08 Ø0.08
Sensing distance, Sna Beam Catalog
Type
2.2 2.2 2.2 (max.) standard w/ XUFZ01 lenses Diameter Number

XUFS0520 XUFS2020 Glass Fiber Optics – Threaded Tip 3' (1 m) long


Thru-beam (pair) 9.84" (250 mm) 98.4" (2500 mm) 1x0.04" (1 mm) XUFS2020
Proximity/diffused
3.44" (87 mm) 34.4" (870 mm) 2x0.04" (1 mm) XUFS0520
Dual Dimensions inches (bifurcated)
mm
a Nominal sensing distance. Recommended usable distance is x0.8 of the nominal sensing distance. This will cover variances in
temperature, supply voltage and manufacturing tolerances.

120
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFN Plastic and XUFS Glass Fiber Optics
XUFN Plastic and XUFS Glass Fiber Optics

Specifications
Fiber optic type XUFN XUFS
Temperature -14° F to 140° F (-25° to 60° C) -40° F to 356° F (-40° to 180° C)
XUFZ02
Vibration 7 G, 1.5 mm amplitude
Shock 30 G, for 11 ms
core PMMA glass
Materials
jacket PE (polyethylene) stainless steel

Photoelectric Sensors
0.04" (1 mm) OD 0.39" (10 mm) –
Minimum bend radius
XUFZ01 0.08" (2.2 mm) OD 1.0" (25 mm) 3.5" (90 mm)

Accessories
Description Catalog Number
Lenses (pair) for standard threaded tips x10 Magnification t XUFZ01
fois
11 eule once
F-Z e s
XU u un hole
90° mirrors (pair) for standard threaded tips XUFZ02
† o ch
1 tr e ea
er s
lis e u
Uti leas
P Fiber cable cutter (one is included with each fiber optic cable) XUFZ11
4 mm stainless steel sheathing XUFZ210
6 mm stainless steel sheathing XUFZ310
XUFZ11 t Will improve range approximately 3 to 5 times

Sensing range for length for cable


200 mm

150 mm
120 mm 1
100 mm
70 mm
50 mm
2
0 mm
2m 5m 10 m

1 XUFN12301L10
2 XUFN05321L10

XUFZk10

121
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN Fiber Optic Cables for Specific Applications
XUFN Fiber Optic Cables for Specific Applications

M2.6x0.45 Features:

0.47 0.12
12 3
0.79
20 Suited for specific applications which were difficult to tackle in the past.
M8 x 1.25 M4x0.7

XUFNP P for power:


Ø0.08
Ø0.08 2.2 • Increases sensing distance by 40%
2.2
Long Range • Burns through pollutants for reliable detection
Photoelectric Sensors

Thru-Beam Power
High Focus XUFNkP…
Lens XUFNS S for soft:
XUFN2L…
• Flexible enough for maneuvering tight corners
M2.6x0.45 • Bend radius of 4 mm
0.47 0.12
12 3

Ø0.19
5
0.79

M4x0.7 XUFNT T for Teflon:


20

Ø0.16
• Resists chemical aggressions
2000
78.7

4
Ø0.08
2.2 • Ideal for food and beverage, assembly and electronic, semiconductor
Soft Flexibility
XUFNkS… XUFNL L for lens:
3.93
100

Ø0.08
2.2
• Integrated focusing lens for precise “spot” sensing
Teflon Coated • Senses longer distances
XUFNkT…
• Convergent beam types sense to three different ranges

Dual Dimensions inches Sensing Cable Beam Sensing Dimensions Catalog


mm
Mode Length Diameter Distance HxWxD Number
High Focus Lens
Convergent 6.6’ (2 m) 0.1" (2.5 mm) 0.4" (10 mm) 1.2, 0.35, 1.2 (30, 9, 30) XUFN5L01L2
Convergent 6.6’ (2 m) 0.2" (5 mm) 0.8" (20 mm) 1.22, 0.47, 1.33 (31, 12, 34) XUFN5L02L2
Convergent 6.6’ (2 m) 0.31" (8 mm) 1.18" (30 mm) 1.22, 0.47, 1.2 (31, 12, 30) XUFN5L03L2
Thru-Beam 6.6’ (2 m) 0.31" (8 mm) 59"(1500 mm) see left XUFN2L01L2
Thru-Beam 33’ (10 m) 0.31" (8 mm) 59" (1500 mm) see left XUFN2L01L10
Long Range Power
Thru-Beam 6.6’ (2 m) 0.16" (4 mm) 11.8" (300 mm) f see left XUFN2P01L2
Thru-Beam 33’ (10 m) 0.16" (4 mm) 11.8" (300 mm) f see left XUFN2P01L10
Diffuse 6.6’ (2 m) 0.16" (4 mm) 3.7" (95 mm) see left XUFN5P01L2
Diffuse 33’ (10 m) 0.16" (4 mm) 3.7" (95 mm) see left XUFN5N01L10
Soft Flexibility
Thru-Beam 6.6’ (2 m) 0.16" (4 mm) 3.9" (100 mm) q see left XUFN2S01L2
Thru-Beam 33’ (10 m) 0.16" (4 mm) 3.9" (100 mm) q see left XUFN2S01L10
Diffuse 6.6’ (2 m) 0.16" (4 mm) 2.1" (55 mm) see left XUFN5S01L2
Diffuse 6.6’ (2 m) 0.16" (4 mm) 2.1" (55 mm) see left XUFN5S01L10
Teflon Coated
Thru-Beam 6.6’ (2 m) 0.16" (4 mm) 3.9" (100 mm) see left XUFN2T01L2
Diffuse 6.6’ (2 m) 0.16" (4 mm) 2.7" (70 mm) see left XUFN5T01L2
f with XUFZ01 2000 mm
q with XUFZ01 750 mm

Convergent High Focus Lens


D D D
W W W
H H H

XUFN5L02…
XUFN5L01… XUFN5L03…

122
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFN Fiber Optic Cables for Specific Applications
XUFN Fiber Optic Cables for Specific Applications

Un-terminated Individual Cable


Sensing Distance, Sn@2m a Beam Outside Catalog
Length
(Straight Cable Only) Diameter Diameter (OD) Number
Straight cable
33' (10 m) 9.84" (250 mm) 0.04" (1 mm) 0.09" (2.2 mm) XUFZ910
Un-terminated cable
66' (20 m) 9.84" (250 mm) 0.04" (1 mm) 0.09" (2.2 mm) XUFZ920
33' (10 m) 14.8" (375 mm) 0.06" (1.4 mm) 0.09" (2.2 mm) XUFZ911
66' (20 m) 14.8" (375 mm) 0.06" (1.4 mm) 0.09" (2.2 mm) XUFZ921

Photoelectric Sensors
a Nominal sensing distance. Recommended usable distance is x0.8 of the nominal sensing distance. This will cover variances in
temperature, supply voltage and manufacturing tolerances.

XUFZ13, XUFZ03
Separate Tips and Mounting Brackets (pair) for un-terminated cables – Thru-Beam mode
Sensing Distance a
Mounting 1.4 mm beam Catalog Number
1 mm beam Diameter
Diameter
Axial 3.94" (100 mm) 5.91" (150 mm) XUFZ13
Non-Magnified Frontal 2.76" (70 mm) 3.94" (100 mm) XUFZ14
Side 2.76" (70 mm) 3.94" (100 mm) XUFZ15
XUFZ14, XUFZ04 Axial 31.50" (800 mm) 23.62" (600 mm) XUFZ03
Magnified Frontal 23.62" (600 mm) 15.75" (400 mm) XUFZ04
Side 23.62" (600 mm) 15.75" (400 mm) XUFZ05
a Distance is at 2m cable length
+ For other cable length:
5 m cable – apply a reduction factor of 0.70 x Sn
10 m cable – apply a reduction factor of 0.50 x Sn
20 m cable – apply a reduction factor of 0.30 x Sn

XUFZ15, XUFZ05 Sensing range of cable length for unterminated cables


300 mm
250 mm

200 mm
1
150 mm
120 mm
100 mm
2
50 mm
0 mm
4 m 10 m 20 m 30 m 40 m
1 XUFZ911, 921
2 XUFZ910, 920
L = 59.0 Ø0.08
1500 2.2

0.7
Ø0.08 18
2.2

Multiple Head Thru-Beam (pair) 6.6’ (2 m) length


L = 19.7 Ø0.04
500 1 Sensing distance, Sn a Beam Outside Catalog
Tip
(max.) standard w/XUFZ01 lenses Diameter Diameter (OD) Number
0.39
10

M0.11x0.02 8 head, threaded 1.48" (38 mm) – 16 x 0.01" (0.265 mm) 0.09" (2.2 mm) XUFN02801
3x0.5 a Nominal sensing distance. Recommended usable distance is x0.8 of the nominal sensing distance. This will cover variances in
temperature, supply voltage and manufacturing tolerances.

XUFN02801

Dual Dimensions inches


mm

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Page 166

123
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Classic XUD and XUD PLUS Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
XUD and XUD PLUS Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics

Features

XUD Amplifiers
• Miniature DIN rail or lateral mounting
• Selectable Light/Dark
• 2 potentiometer adjustments (coarse, fine)
Photoelectric Sensors

• 2-LED alignment system


• Nano style (8 mm) 4 pin connector versions for fast replacement and ease of wiring
• Gasketed transparent top cover and fiber optics entrances provide a high degree of
environmental protection
• Fast response time
• Short circuit protection
• Reverse polarity protection

XUD PLUS Universal Amplifiers


• Alarm output and test input options available
• Remote potentiometer offered
• Crosstalk immunity allows side by side mounting without interference

Not for Use on New


• Higher frequency: selectable from 1000 Hz or 4000 Hz
• On/off delay timer (fixed at 30ms) selectable by switch
Variation of sensing distance
Thru-beam or diffuse system

n s – L im ite d P ro d u c t XUD Amplifiers for XUFN Plastic and XUFS glass fiber optics

Applicatio
related to sensitivity adjustment Amplifiers – DC models
Sensing distance
Voltage rangea Operating Catalog

Availability
(%) Circuit Type Output Mode Load Current
Max. Frequency Number
100
1 6.6’ (2 m) cable
80
PNP Light/dark 10-30 V 100 mA 500 Hz XUDH003537
60 NPN Light/dark 10-30 V 100 mA 500 Hz XUDJ003537
40
2 Connector – nano style c
20 PNP Light/dark 10-30 V 100 mA 500 Hz XUDH003537S
NPN Light/dark 10-30 V 100 mA 500 Hz XUDJ003537S
0
0 0.25 0.5 0.75 1 N
N: Number of turns on potentiometer P1
1 Potentiometer P2 at maximum XUD PLUS Universal Amplifiers
2 Potentiometer P2 at minimum
.2 meters (7.8") max sensing ranget in Thru-beam mode
.7 meters (2.8") max sensing ranget in Diffuse mode
Voltage range Operating Catalog
Circuit Type Output Mode Load Current
Max. Frequency Number
Verification of correct operation
Cable – 2 meter
Intensity of beam received
PNP Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDH003937
NPN Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDJ003937
1.2 Connector – nano style c
1
PNP Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDH003937S
0.8
NPN Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDJ003937S
Remote potentiometer
Red LED
PNP Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDH003997S
Green LED
t When used with standard 1mm diameter plastic fiber optics
Optimum + a Including ripple
– alignment c See p. 518 for matching connector cables

LED off

LED on

124
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Classic XUD and XUD PLUS Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
XUD and XUD PLUS Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics

Wiring Amplifier Specifications


Mechanical
Cable Version Temperature range 13° F to 131° F (-25° C to 55° C)
BN Light Mode: NEMA Type 1, 3, 4, 6, 12, 13
+ Connect to +
OG Enclosure rating IP66 for 2.2 mm OD cables
IEC Type
PNP Dark Mode: IP64 for 1 mm OD cables
BK Connect to - Vibration 10 G, 0.6 mm amplitude

Photoelectric Sensors
H Shock 50 G, for 11 ms
Sourcing BU - Cable 4 #24 AWG, PVC
Electrical
40 mA
Power supply current
BN + < 35 mA for XUD PLUS

BK 1.5 Vdc
Light Mode: Voltage drop across switch
Connect to + <1.8 Vdc for XUD PLUS
NPN
OG Short circuit protection Yes
J Dark Mode: Overload protection Yes
Connect to -
Sinking BU - Reverse polarity protection Yes
On delay 1 ms 500 ms (XUD Plus) t
Off delay 1 ms 500 ms (XUD Plus) t
Power up delay 30 ms
Wavelength 660 nm (red)
Connector Version
E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
Light + ®

2 (WH) (BK) t Quick response mode available, 120 ms. Sn is cut in half in quick response mode.

Not for Use on New


Dark Ð 4

(BN) 1 +
3 - (BU)

n s – L im ite d P ro d u c t
Applicatio
Availability
XUDH0039975
Remote Potentiometer

1 +
2 R -
3
12 V, R = 200 k½
24 V, R = 50 k½

Connector Version

Gain
Control 2 Output
4

1 3
+ –

Connector Cables (M8 or S suffix)


XSZCS141 Nano Conn., 4 pin, 2 m, straight
XSZCS151 Nano Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . Page 157

125
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
XUV Sensors with Separate Optical Heads

The XUV series of separate optical sensing heads and amplifiers provides maximum flexibility
in difficult applications.
Features:

M 18 x 1 Thru beam M 18 x 1 -- Reflex • Thru-beam retro-reflex and proximity diffuse in several housing styles:
Cylindrical – threaded or clip-on for easy replacement
• Extra flat for hard to access places, i.e. small conveyers
Photoelectric Sensors

• Fork style for edge or mark detection


• Convergent for background suppression
• Visible red or green light for easy positioning and better contrast detection
Clip-on -- Thru beam Clip-on -- Reflex
• UL Listed c
• CSA Certified
Optical Sensing Heads
Nominal Sensing Catalog
Description Light Beam Dia. Type
Distance a Number
Thru-beam
Threaded (M-8 x 1) 24' (7.3 m) IR 0.43" (11 mm) Emitter XUVN06240
Receiver XUVN06244
Clip-on 24' (7.3 m) IR 0.43" (11 mm)
Extra flat--Thru beam Extra flat--Diffuse Emitter XUVN06250
Receiver XUVN06254
Extra flat 9" (23 cm) IR 0.118" (3 mm) Emitter XUVN20210
Receiver XUVN20214
Fork
0.787" (20 mm) Green 0.04" (1 mm) – XUVN0243G
Red 0.04" (1 mm) – XUVN0243R
0.197" (5 mm)
Green 0.04" (1 mm) – XUVN0143G
Red 0.04" (1 mm) – XUVN0143R
Retroreflective
Fork 20 mm Fork 5 mm Threaded (M18 x 1) 8' (2.5 m) IR 0.43" (11 mm) – XUVN0244
Clip-on 8' (2.5 m) IR 0.43" (11 mm) – XUVN0245
Proximity Diffuse
Extra flat 2.5" (63 mm) IR 0.118" (3 mm) – XUVN05415
Convergent 0.787" (20 mm) Red 0.08" (2 mm) – XUVN02428
Convergent 0.394" (10 mm) Red 0.04" (1 mm) – XUVN01428
Threaded (M18 X 1) 5" (125 mm) IR 0.43" (11 mm) – XUVN10445
For amplifiers, see Page 128.
a Excess gain one – in normal conditions, maximum usable sensing distance is 75% of normal.
Convergent 20 mm Convergent 10 mm c The heads are not provided with the listing mark.

126
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Technical Data
XUV Sensors with Separate Optical Heads / Technical Data

Mechanical Characteristics – Thru-beam Devices


Fork Fork
Threaded Clip-on Extra flat
0.8" (20 mm) 0.2" (5 mm)
Operation from -13° F to +131° F (-25 to +55° C).
Temperature range
Storage from -22° F to +158° F (-30 to +70° C)
Resistance to vibration 7 G amplitude ± 0.06" (1.5 mm) F = 10 to 55 Hz
Resistance to shock 50 G, 3 axes, 3 times

Photoelectric Sensors
Degree of protection
k NEMA Type 1, 4, 13 1, 5 1, 4, 6, 6P, 13
k IEC Type IP66 IP50 IP67
Cable 0.08 x 0.16" (2.2 x 4 mm) Cable dia. 0.07" (1.8 mm) Cable dia. 0.07" (1.8 mm)
oval section
Connections Length: 19.7’ (6 m) Length: 6.5’ (2 m) Length: 6.5’ (2 m)
Cross section 0.01"2 (0.3 mm2 ) Cross section 0.01"2 (0.3 mm2 ) Cross section 0.01"2 (0.3 mm2 )
Shielded (AWG 22) (AWG 22) (AWG 22)
Material Case: ABS/PC; Cable: PVC
880 nm 880 nm 880 nm Green 565 nm 565 nm
Wavelength
Red 660 nm 660 nm

Mechanical Characteristics
Retroreflective Diffuse Convergent
Threaded Clip-on Extra flat Threaded 20 mm 10 mm
Operation from -13°F to +131°F (-25 to +55°C).
Temperature range
Storage from -22°F to =158°F (-30 to +70°C)
Resistance to vibration 7G amplitude ± 0.6" (1.5 mm) F = 10 to 55 Hz
Resistance to shock 50G, 3 axes, 3 times
Degree of protection
NEMA Type 1, 4, 13 1, 5 1, 4, 13 1, 5
IEC Type IP66 IP50 IP66 IP50
Cable 0.08 x 0.16" (2.2 x 4 mm)
oval section Cable dia. 0.07" (1.8 mm) Cable dia. 0.07" (1.8 mm)
Length: 13’ (4 m) Length: 6.5’ (2 m) Length 6.5’ (2 m)
Connections
Cross section 0.01"2 (0.3 mm2) Cross section 0.01"2 (0.3 mm2) Cross section 0.01"2 (0.3 mm2)
shielded (AWG 22) (AWG 22)
(AWG 22)
Material Case: ABS/PC; Cable: PVC
Wavelength 880 nm 880 nm 660 nm 660 nm

E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
®

127
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifiers, DC
XUV Sensors with Separate Optical Heads / Amplifiers, DC

The XUV series of amplifiers designed for use with XUV optical sensing heads provide
maximum flexibility in difficult applications. Features include:
• DIN rail mounting
• Light/Dark programmable
• 3-LED alignment system
• Gating (synchro) input for each channel (except XUVF)
Photoelectric Sensors

• UL listed, CSA certified


XUVH/J
XUVH/J
• 2 potentiometers (coarse and fine)
• Fixed time (40 ms) pulse stretcher (monostable) selectable ON/OFF
• Marginal Detection Signal (MDS) output (alarm signals before sensor quits)
• System test input – turns off Emitter, Receiver follows suit if system is OK
• DC single channel, pre-wired
• Standard and very fast response time versions available

XUVF
XUVF • AC single and dual channel, relay output
• Screw terminals and power supply (12 Vdc)
• Fixed time (40 ms) pulse stretcher XUVF – selectable ON/OFF

DC Amplifiers
Operating
Test Synchro Catalog
Output Frequency
Output Input Number
Max.
PNP 500 Hz/2500 Hz Yes Yes XUVH003530
NPN 500 Hz/2500 Hz Yes Yes XUVJ003530

AC Amplifiers
Operating
No. of Test Synchro Catalog
Frequency
Channels Output Input Number
Max.
1 50 Hz – – XUVF000510
2 50 Hz – Yes XUVF000511
For optical heads, see Page 126.

128
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifier Technical Data
XUV Sensors with Separate Optical Heads / Amplifier Technical Data

Operating and Electrical Characteristics


DC AC
Standard Fast 1 Channel 2 Channel
Temperature range -13° F to +131° F (-25° C to +55° C)
NEMA Type 1, 5
Enclosure rating
IEC Type IP50
Vibration resistance 7 G amplitude ± 1.5 mm (f =10 to 55 Hz)

Photoelectric Sensors
Shock resistance 30 G
4.5 mm dia. (0.18") Length 2 m (6.6") Terminals 1-8: 16-20 AWG
Wiring
#22 AWG (0.2 mm2) Terminals 9-29: 20-24 AWG
Plastic ABS Plastic ABS
Housing material
Cable PVC Cable PVC
Voltage range (max.) 10 - 30 Vdc including ripple 90 - 264 Vac
Output current (max.) 100 mA 1 A (resistive load)
Short-circuit/overload protection Standard –
Relay output voltage (max.) – 250 Vac, 30 Vdc
Power supply current (no load) 45 mA 30 mA 80 mA
Voltage drop (max.) 1.5 V –
Operating frequency (max.) 500 Hz 2500 Hz 50 Hz 50 Hz
On/Off delay 1 ms 0.2 ms 10 ms 10 ms
Power up delay 1 ms 0.2 ms 10 ms 10 ms
Pulse stretcher (monostable) delay 40 ms 40 ms 40 ms
Test input voltage (max.) 1.5 V @ 1 mA – –
Test output current (max.) 50 mA – –
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V per meter)
DC: IEC 61000-4-2, L2a (4 kV)
Electrostatic discharges
Protective Circuitry AC: IEC 61000-4-2, L3a (8 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
®

a L indicates level number.

Replacement Parts
Description Catalog Number
Protective cover for DC amplifiers XUVZ02

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Page 166

129
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifier Technical Data
XUV Sensors with Separate Optical Heads / Amplifier Technical Data

DC Amplifier XUVH XUVJ Test input (Beam break) Variation of sensing distance
PNP output NPN output Brown + Depending on the sensitivity adjustment
PNP
Synchro MSD Purple sensing dist. (%) P2 (Fine) Max.
E
W 100
Grey H Gating sensor BN LOAD

J Blue -
80
BN BK
H LOAD

BK BU Normal = Emitter ON 60
LOAD
BU NPN Brown + 40 P2 (Fine) Min.
Photoelectric Sensors

Grey
W MSD LOAD Synchro Purple 20
E
J Gating sensor 0
Blue -
0 0.25 0.5 0.75 1
Number of turns of potentiometer P1
Test = Emitter OFF

Marginal Detection LED Marginal Detection Signal (MDS) Optical head wire stripping dimensions
Excess gain optical axis .27 .15
Red LED
7 4
Output t t
1.2 .19 .59
1 MDS
5 15
0.8
State 0 : output off
State 1 : output on
Red LED
t = 40 ms*
Green LED * time delay to avoid nuisance signals
Optimum
alignment
angle
LED off LED on Dual Dimensions inches
mm

Sensitivity adjustment Switch functions Optical head DC wiring diagram


1 2 3 4
terminal
OUT HD 1 A 1 Emission (red)
1 2 Emission shield

3 Reception (white)
L COARSE H L FINE H
L L 0 T 4 Rec. shield
2 UNST.
4
3
5 1 Response time selector switch:
3 6 H = quick response time 4
L = standard response time
2 Light/dark switching selector switch: 1
D = dark switching 2
L = light switching
3 Time delay selector switch:
1 Plastic screwdriver (supplied) 1 = ON
2 Potentiometer P2 (fine adjustment) 0 = OFF
3 Potentiometer P1 (coarse adjustment)
4 White wire function selector switch:
4 Red LED A = Test output
5 Green LED T = Test input
6 Yellow LED

130
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifier Technical Data
XUV Sensors with Separate Optical Heads / Amplifier Technical Data

AC wiring diagrams

1 Channel Amplifier: XUVF000510


Terminals
Terminals 2 L1 supply
4 L2 supply
13 15 17 19
6-8 Relay output (1 contact)

Photoelectric Sensors
13 Receiver (white wire)
15 Receiver (shielded cable)
Potentiometers
17 Emitter shield
A
19 Emitter (red wire)
Switches LED Indicators
1 2
1 2 3 1 Power supply (green)
LED indicators
2 Unstable (red)
3 Output (yellow)
2 4 6 8
Potentiometers
Terminals A Sensitivity adjustment
Switches
1 Light/Dark

2 Monostable timer (pulse stretcher)

2 Channel Amplifier - Form C relay: XUVF000511


Terminals Switches
10 12 14 16 18 20 1 L1 supply 1 Monostable timer, channel 1 (pulse stretcher)
Terminals 2 L2 supply 2 Light/Dark, channel 1
9 11 13 15 17 19 3 N.C. output, channel 2 3 Monostable timer, channel 2 (pulse stretcher)
4 N.C. output, channel 1 4 Light/Dark, channel 2
5 Common, channel 2 Potentiometers
Potentiometers 6 Common, channel 1 A Sensitivity adjustment, channel 1
A B 7 N.O. output, channel 2 B Sensitivity adjustment, channel 2

Switches 8 N.O. output, channel 1 LED Indicators


123 4
1 2 3 5 9 Output for synchro sensors 12Vdc (-) 1 Green: Power supply
4
LED indicators 10 Output for synchro sensors 12Vdc (+) 2 Red: Unstable, channel 1
11 Synchronization, channel 2, NPN 3 Yellow: Output, channel 1
2 4 6 8 12 Synchronization, channel 1, NPN 4 Red: Unstable, channel 2
13 Emitter, shielded, channel 1 5 Yellow: Output, channel 2
Terminals
14 Receiver, channel 1 (white wire)
1 3 5 7
15 Emitter, channel 1 (red wire)
16 Receiver, shield, channel 1
17 Emitter, shield, channel 2
18 Receiver, channel 2 (white wire)
19 Emitter, channel 2 (red wire)
20 Receiver, shield, channel 2

131
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUK Sub-compact Photoelectric Sensors
Transparent Detection with Timer – DC
XUK SubCompact Photoelectric Sensors / Transparent Detection with timer - DC

Features:
• For detection of PVC, PET and glass targets at a high rate of speed
• Easy set up with a self-teaching feature, enabled by the press of a button
• Alarm output warns of marginal signal
• Time delay (perfect for avoiding jamming on bottling line) adjustment by potentiometer
Photoelectric Sensors

• Cable or Micro connector style available


Dual Dimensions inches Load Operating
mm
Circuit Output Voltage Catalog
1.97 Current Frequency
50 Type Type Range Number
1.57 Max. Max.
40
Polarized Retroreflective – DC, 1.5 m (4.9') Nominal Sensing Distance q
Cable style - 2 Meter (6.6’) length
PNP/NPN Light/Dark 12 - 24 Vdc 100 mA 1500 Hz XUKT1KSML2
Micro style connector
PNP/NPN Light/Dark 12 - 24 Vdc 100 mA 1500 Hz XUKT1KSMM12
q 50 mA alarm output

.19 2xØ4
5
1.57 Recommended mounting distances
40 max. 4.9' (1.5 m)
min. 0
1.57
40

1.34
1.57
40

34

10° Ø4,5
2.30
58
1.57
1.97 40
50
.79
20

.71 .86
18 22

Ø6x12 .47 .27


12 7
2.30
.71

58
18

.59
15
Ø6 .51
13

Ø6x13
.47 .19
12 5
2.56
65
3.23
82
3.15
80

132
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUK Sub-compact Photoelectric Sensors
Transparent Detection with Timer – DC
XUK SubCompact Photoelectric Sensors / Transparent Detection with Timer - DC

Wiring Specifications
Mechanical
Operation 13 to 131° F (-25 to 55° C)
Temperature Range
PNP Yellow on Storage 40 to 158° F (-40 to 70° C)
NEMA Type 3,4,4X,6,12,13
Enclosure Rating
BN + IEC Type IP67 conforming to IEC 60529
Vibration 7G amplitude + 1.5 mm (f=10 to 55 Hz)
BK
– Shock Resistance 30G for 11 ms conforming to 68-2-27
BU Connection 6 mm dia. PVC cable with 0.34 mm wire

Photoelectric Sensors
Tightening Torque (Maximum) 5 N•m
Case PC/ABS
Enclosure Material Lens PMMA
NPN Cable PvR
Yellow on
Electrical
BN + Voltage Limit (Including Ripple) 10 - 30 V
Voltage Drop (Across Switch, Closed State) 2V
BK
– Current Consumption (Maximum) (No Load) 35 mA
BU Yellow Output LED Yes
Red Stability LED Yes
Power-up Delay (Maximum) 80 ms
On Delay (Maximum) 0.3 ms
Off Delay (Maximum) 0.3 ms
Short Circuit Protection Yes
Protective Circuitry Overload Protection Yes
Reverse Polarity Protection Yes

Agency Listings
®

Control Panel Access


1.L.ON D.ON
6 2.TIM. ON OFF

1 Timing Function
A 2 1. Light on - Dark on
3 2. Timer on - Timer off
3. Delay / One shot
4 4. On Delay / Off Delay
7 T 8 5. PNP or NPN
5
B T = Time delay 6. Yellow LED - output on and learning mode
7. Red LED - alignment and alarm
3.DL 1 SHOT 8. Self teaching button (SET)
4.ON OFF
5. PNP NPN

Time Delay No time delay Normal time delay (T) time Normal time delay (T) time Monostable time delay (T)
delay on trip "OFF-DELAY" delay on reset "OFF-DELAY"
Switch Positions
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
Receiver state Beam made
Beam broken

T T T T T T T
Light switching Relay on
1 Relay off

T T T T T T T
Dark switching Relay on
1 Relay off

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . Page 156

133
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM Miniature, Color Mark Detector
DC
XUM Miniature, Color Mark Detector / DC

High performance, self contained medium range miniature photoelectric sensors for color mark
detection.
Features:
• Very small dimensions 1.4" x 0.87" x 0.39" (35.5 x 22.1 x 9.9mm)
• Marginal Detection Signal (MDS) provided for alarm output and alignment help.
Photoelectric Sensors

• Test input – system checking


• Light/Dark selectable
• Green and red light for difficult contrast sensing
• 2 LED alignment system
• NEMA Type 4, 6, 6P ratings
• Mounting bracket included.
• UL Listed, CSA Certified
Horizontal Load Operating
Output Voltage Catalog
Type inclination of Current Frequency
Mode Range Number
reader q Max Max. Max.
Color mark detectors – Sensing Range 0.6" (15 mm)
Red light
PNP 3 wire Light /dark 12-24 Vdc 30° 100 mA 500 Hz XUMH15353R
NPN 3 wire Light /dark 12-24 Vdc 30° 100 mA 500 Hz XUMJ15353R
Green light
PNP 3 wire Light /dark 12-24 Vdc 15° 100 mA 500 Hz XUMH15353G
NPN 3 wire Light /dark 12-24 Vdc 15° 100 mA 500 Hz XUMJ15353G
q To eliminate stray reflection

XUM Color Mark Detector Selection Chart


Mark Color
Color of object (surface background) Black Red Orange Yellow Green Blue White
White G,R G – – G,R G,R
Blue – R G,R G,R – G,R
Green – R G,R G,R – G,R
Yellow G,R R – G,R G,R –
Orange G,R G – G,R G,R –
Red R R G R R R
Black R G,R G,R – – G,R
R=Red light G= Green light – = Marginal detection
Note: Where both Green and Red light meet the application select the Red light as it is more sensitive to contrasts.

Front face of reader diameter of light


spot at 15 mm : 2 mm
(side view)
3.5 mm 3.5 mm

optical
axis
recommended
Minimum detectable 16" operating zone
width of mark: 1mm

A B

15 mm Depth of field (mm) A B


green emission 1 1
Maximum linear speed of mark:
2 mls (for 2mm wide mark) red emission 3 3

134
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM Miniature, Color Mark Detector
DC
XUM Miniature, Color Mark Detector / DC

Wiring Specifications
Mechanical
Temperature range -13° F to 131° F (-25° C to 55° C)
PNP output NEMA Type 1, 3, 4, 6, 6P, 12, 13
Enclosure rating
Prog. + Light IEC Type IP67 conforming to IEC 60529
Enclosure material Housing: ABS/PC; Lens: PMMA,PC; Cable: PVC
OG - Dark
BN
Vibration resistance 7 G amplitude ± 1.5mm (f= 10 to 55 Hz)
H BK Shock resistance 50 G 3 axes, 3 times

Photoelectric Sensors
LOAD
BU Wiring 6’ cable, 0.18" dia., 3 x #24 AWG
W MDS LOAD
Electrical
Voltage limits (including ripple) 10-30 Vdc
Load current max. 100 mA, protected against overload and short circuit
NPN output Voltage drop “closed” state 1.5 V
MDS No load current consumption 35 mA
W LOAD
Test output current max. 50 mA
BN Test input voltage max. 1.5 V @ 1 mA max.
J BK LOAD

BU Switching frequency max. 500 Hz


+ Light Power up delay max. 1 ms
OG SELECT
On/Off delay max. 1 ms
- Dark
Red color mark 660 nm
Wavelength
Green color mark 565 nm
Beam break test Ambient light immunity 10,000 LUX
(purple wire) Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Beam present Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
E Brown + Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
®

Purple
a L indicates level number.

Accessories
Blue -
Description Sensing Distance Catalog Number
Thru-beam aperture (1) 0.5 mm and (1) 1 mm 4.5 cm (1.78") XUMZ01
Beam broken Thru-beam aperture (1) 1.5 mm and (1) 2 mm 4.5 cm (1.78") XUMZ03

E Brown +

Purple

Blue -

135
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUMW Liquid Detection Sensor
DC
XUMW Liquid Detection Sensor / DC

Features:
• Reliable detection of transparent or color liquids
• Able to detect liquid in thick containers
• Ability to control container filling
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Photoelectric Sensors

Type Range Type Maximum Maximum


Thru-Beam – 200mm (7.9") Nominal Sensing Distance
PNP/NPN N.C. / N.O. 12-24 Vdc 2 m (6.6’) cable 100 mA 1000 Hz XUMW1KSNL2

Application Examples

Dimensions
d
0.06

1.6 0.2 (1) 0.5 (2)


1.5

41 5.6 13
0.45
11.5
0.9
23

1.2
32

d
0.4

(3)
10
0.1
2.5

0.6 0.8 1.1


d = 10 cm d = 20 cm
16 20 28

Principle of Detection Light Emission Curve


0.6 (15)
0

Level absoption (%)


0.4 (10) 2
0.12 3
3.2 2
20
0.08

1
0.8 2

40
20

60
0.12
3
Intensity of
beam 80

100
500 1000 1500 1700
Dual Dimensions inches 1100 1450
mm Transmission wavelength (nm)

136
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUMW Liquid Detection Sensor
DC
XUMW Liquid Detection Sensor / DC

Specifications
Wiring Mechanical
200 mm for optimum liquid detection
Emitter Nominal Sensing Range (Sn)
10 m as standard thru-beam
Operation 32 to +104 ° F (0 to +40 ° C)
Temperature Range
Storage 24 to +122 ° F(-5 to +50 ° C)
Enclosure Rating IEC Type IP65 conforming to IEC60529

Photoelectric Sensors
Black PNP Output Black PNP Output Vibration 25 gn, amplitude +/- 2mm (f=10 to 55 Hz)
White NPN Output White NPN Output Shock Resistance 30 gn for 11ms conforming to IEC 60068-2-27
WH WH Output Yellow
LED indicator
Signal Stability Green
Case PBT
Enclosure material
Lens Polycarbonate
N.C. N.O.
(no object present) (no object present) Connection 2 m (6.6’) cable, 4 mm O.D. 2, 3 conductor x0.2 mm2
Light emission Infrared (1450 nm)
Electrical
Voltage Range 12-24 Vdc
Voltage limit (including ripple) 10-30 Vdc
Operating Frequency 1000 Hz
Current consumption (no load) 45 mA
Voltage Drop (max.) 2V
Power-up delay (max.) 50 ms
On-delay (max.) 0.5 ms
Off-delay (max.) 0.5 ms

Agency Listings

Excess Gain Curve Stability Curve


Gain
Signal
104 level 10
5
2
2
103 1,25
500
1
0,75
200
100

50
Output On
20 Yellow LED Off
10 Stability On
Green LED Off
5

2
1
0,1 0,2 0,5 1 2 5 10 20 50 100
D (m)

Principle of Function Functions


Signal level

1,15

0,75
1 2 3 4

LED
1 Yellow output LED
Time 2 Green stability LED

ON Potentiometer
OFF 3 Sensitivity adjustment switch
4 Light / Dark switching programming
ON
OFF

ON
OFF

137
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUR Color Mark Registration, DC
XUR Color Mark Registration, DC

Features:
• 20 turn sensitivity/potentiometer
• Light/dark selectable
• Red or green lens option, selectable via adjustment screw
• Standard Micro style connector receptacle t
Photoelectric Sensors

• 20 ms off delay, selectable by internal jumper


• Heavy duty metal enclosure
• Front or side sensing option, modifiable by customer
Load Operating
Circuit Output Voltage Catalog
Current Frequency
Type Mode Range Number
Max. Max.
Diffuse - 9mm (.354") Nominal Sensing Range q
PNP/NPN Light/Dark 12-24 Vdc 200 mA 10K Hz XURK0955D
t See p. 518 for matching connector cables
q 7mm with XURZ02 or 18mm with XURZ01

Maximum vertical inclination Programming features


5 < α < 20
α α
5 5
Light/dark
switching

Threshold
adjustment D
L Output state
PUT
OUT LED

Red/green
An angle of 5 to 10° from vertical is recommended transmission
for reflective or transparent surfaces. (switch fitted with LEDs to assist
protective cover) adjustment
Maximum vertical inclination: 20°

Detection zone (in/mm) Size of mark (in/mm)

A
.20
5

.06
1.5
C

Note: Maximum linear speed of mark is 10 ms (for 1 mm wide mark)

A B C
XURK 9 5 1.5
XURK + XURZ01 18 7 2
XURK + XURZ02 7 4 1

138
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUR Color Mark Registration, DC
XUR Color Mark Registration, DC

Wiring Specifications
Connector Mechanical
1 (+) Operation 14° to 131° F (-10° to 55° C)
Temperature range
Storage -4° to 158° F (-20° to 70° C)
2 4
Output Enclosure rating IEC Type IP67 conforming to IEC60529 and IP673, NCF 20-010
Vibration 7 G amplitude ±.6 mm conforming to IEC 60068-2-6
3 (–)
Shock resistance 30 G for 11 ms, conforming to IEC 60068-2-7

Photoelectric Sensors
Light mode Case ZAMAC
Enclosure material
Lens Glass
PNP output
Wiring Micro connector
1 + Spot dimensions 1.5 x 5 (min. detectable width 0.5mm)
4
Max. Linear speed of mark 10 ms (for 1 mm wide mark)
3 – Max. Vertical inclination of reader 20°
2
Electrical
Voltage range 12 - 24 Vdc
NPN output
Voltage limit (including ripple) 10 - 30 Vdc
1 + NPN 1.2 V
Voltage drop (across switch, closed state)
4 PNP 2.2 V
3 – Load current (max.) 100 mA
2
Current consumption (max.)(no load) 80 mA
Operating frequency (max.) 1000 Hz
Power-up delay (max.) 100 ms
Dark mode On delay (max.) 50 ms
Off delay (max.) 50 ms
PNP output
Time delay Off delay 20ms
1 +
4 Physical Characteristics
Red 635 nm
3 – Emitter wave length:
Green 565 nm
2
Short circuit protection yes
Protective Circuitry Overload protection yes
NPN output Reverse polarity protection yes
1 +
4
3 –
2
Accessories
Description Catalog Number
Magnifying lens XURZ01
Focusing lens XURZ02

Dimensions Detection curve


2.46 % of signal
.83 2.30 62.5 110
21 58.5 100
M12 90
2 1
8 x M5x5 80
70
60
87 1.10
28

1.10

50
28

3
3.43

40
2.95
75

30
1.64
41.5

20
1.44
36.5

10
0
0 5 10 15 20 25
.16

1.18 .94 .61 Distance (mm)


4

30 24 15.5 1 XURK z z z z z z z
2 XURZ01
3 XURK XURZ02
Connector Cables (M12 or D suffix) Dual Dimensions inches
mm
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

139
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XURK1 Self-Teaching Color Mark Registration, DC
XURK1 Self-Teaching Color Mark Registration, DC

Features:
• Self teaching for memorization of target and precision repeatability
• 0 to 5.5 V analog output, depending on the illumination level of mark
• Magnifying lenses increases sensing distance to 18mm or focuses to 7mm
• Optional straight or 90 ° sensing set up
Photoelectric Sensors

• 20 ms Off Delay built in timing feature


• Automatic sensitivity adjustment by self-teaching
• Automatic light/dark switching, depending on order of teaching (mark or background)
Voltage Load Operating
Circuit Output Voltage Catalog
Drop Current Frequency
Type Mode Range Number
Max. Max. Max.
Diffuse - 9mm (0.354") Nominal Sensing Rangea – Micro Style Connector
PNP/NPN or Analog Light/Dark 12 - 24 Vdc 2V PNP, 2V NPN 200 mA 10000 Hz XURK1KSMM12
a Excess gain one - in normal ambient conditions, maximum usable sensing distance is 75% of normal
a 7mm with XURZ02 and 18mm with XURZ01 (see chart)

.82
1.56 21
40 .33
8
.94
24
.60
Detection Zone and
M12x1
15 Mark Size (mm)

1.10
1.10 28 a
28
3.20
81
1.08
27 b
1.44 8xM5x6
37 c
.55
14

Ø25
a b c
.23 1.66 .17
6 42 4
2.28 1.22 IN mm IN mm IN mm
58 31
XURK1KSMM12 .35 9 .20 5 .08 2

Dual Dimensions inches XURK1KSMM12 + XURZ01 .71 18 .28 7 .08 2


mm
XURK1KSMM12 + XURZ02 .28 7 .16 4 .04 1

Vertical Plane
5° < α < 20°

α α
5° 5° An angle of 5 to 10°
from vertical is recommended
for reflective or
transparent surfaces.
Max. vertical
inclination: 20°

140
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XURK1 Self-Teaching Color Mark Registration, DC
XURK1 Self-Teaching Color Mark Registration, DC

Wiring Specifications
Mechanical
PNP
9 mm
Nominal sensing range
1 + (7 mm with XURZ01,18 mm with XURZ01
2
Spot dimension 1.5 x 5 mm diameter
R
4 0 to 5.5 V Min. detectable width of mark 0.5 mm
3 – Max. linear speed of mark 10 m/s (for 1 mm mark)

Photoelectric Sensors
Operation: 14° to 131° F (-10° to 55° C)
Temperature range
Storage: -4° to 158° F (-20° to 70° C)
NPN Enclosure rating IEC Type: IP67 conforming to IEC 60529
1 +
Vibration 7 G amplitude + 0.65 mm (f=10 to 55 Hz)
2
Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
4
R 0 to 5.5 V
LED indicator type Red - output, green - learning mode
3 –
Enclosure material Die cast Zinc
Sensitivity Adjustment Automatic, through self-teach function
1 (+) Connection M12, 4 pin connector
Light emission Red or green (automatic selection)
Analog 2 4 Solid State
Output Output Electrical DC models
3 (–) Voltage limits (including ripple) 10 - 30 Vdc
Rated Supply Voltage 12 - 24 V (with reverse polarity protection)
Operating Frequency 10,000 Hz
Analog output 0 - 5.5 V (voltage proportional to light reflected by the object)
Current consumption (max.)(no load) 80 mA
Power-up delay (max.) 100 ms
On delay (max.) 50 µs
Off delay (max.) 50 µs
Timing 20 ms “off delay”

Accessories
Description Catalog Number
Mark magnification lens XURZ01
Mark reduction lens XURZ02

Excess Gain Curve Optional Lenses for Focusing or Magnifying


% of signal

100
90
2 1
80
70 XURZ01
60
50
40
3
30
20
10
XURZ02

0 XURK1KSMM12 Lens
0 5 10 15 20 25
Distance (mm) 1. Green LED, unit in
learning mode
1 XURK1KSMM12 2. Red LED, output state
2 XURK1KSMM12 + XURZ01
3. Learning mode button
3 XURK1KSMM12 + XURZ02 for mark

4. Learning mode button


for background
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

141
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XURU Ultra Violet (UV) Self-Teaching, DC
XURU Ultra Violet (UV) Self-Teaching, DC

Features:
• Detects invisible marks, glues, varnishes, etc.
• For detection of Ultra Violet marks and products containing UV blueing agents, as used for
packaging identification and quality assurance.
• 0 to 7 V analog output, depending on the illumination level of UV mark
• Self Teaching for memorization of target and precision repeatability
Photoelectric Sensors

• Magnifying lenses increase sensing distance to 18mm or focuses to 7 mm (optional)


• Mounting adjustable in 3 positions (straight or 90°)
• 20 ms Off Delay built in timing feature
• Automatic sensitivity adjustment (self-teaching)
• Automatic light/dark switching, depending on order of teaching (mark or background)
Voltage Load Operating
Circuit Output Voltage Catalog
Drop Current Frequency
Type Mode Range Number
Max. Max. Max.
Diffuse - 9 mm (0.354") Nominal Sensing Rangea – Micro Style Connector
Discrete and
Light/Operate 12 - 24 Vdc 2 V PNP, 1 V NPN 200 mA 2000 Hz XURU1KSMM12
analog outputs
a 7mm with XURZ02 and 18mm with XURZ01 (see chart)

3.2 .60 Detection zone and


81 15
mark size (mm)
Ø25

.33 .82
21 1.22
9 31 a

.17 1.08 1.10 M12x1


4 27 28
.55
14 2.30
58
Ø

1.67
42 .94 .23
8xM5x6 6
24
1.56
40
a Ø
IN mm IN mm
1.44 1.10 XURU1KSMM12 .35 9 .20 5
37 28
XURU1KSMM12 + XURZ01 .71 18 .28 7
Dual Dimensions inches
mm XURU1KSMM12 + XURZ02 .28 7 .12 3
Excess Gain Curve
% of signal

100
90
2 1
80 Vertical Plane
70
5° < α < 20°
60
α α
50
An angle of 5 to 10°
40
3 5° 5°
from vertical is recommended
for reflective or
30 transparent surfaces.
20 Max. vertical
inclination: 20°
10
0
0 5 10 15 20 25
Distance (mm)

1 XURU1KSMM12
2 XURU1KSMM12 + XURZ01
3 XURU1KSMM12 + XURZ02

142
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XURU Ultra Violet (UV) Self-Teaching, DC
XURU Ultra Violet (UV) Self-Teaching, DC

Wiring Specifications
Mechanical
PNP 9 mm
Nominal sensing range
1 + (7 mm with XURZ01,18 mm with XURZ01)
2 UV spot dimensions 5 mm diameter
R
4 0 to 7 V Operation 14° to 131° F (-10° to 55° C)
3 Temperature range
– Storage -4° to 158° F (-20° to 70° C)

Photoelectric Sensors
NEMA Type 3,4,4X,6,6,12,13
Enclosure rating
IEC Type IP67 conforming to IEC 60529
NPN
1 Vibration 7 G amplitude + 0.6 mm (f=10 to 55 Hz)
+
2 Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27

4 LED indicator type Red - output, green - learning mode


R 0 to 7 V
3 – Enclosure material Die cast Zinc
Sensitivity Adjustment Automatic, through self-teach function
Connection M12, 4 pin connector, with adjustable mounting plane
Light emission Red or green (automatically selected) 370 nm
1 (+)
Electrical DC models
Analog 2 4 Solid State Voltage range 10 - 30 Vdc
Output Output
Rated Supply Voltage 12 - 24 V (reverse polarity protected)
3 (–) Operating Frequency 2000 Hz
Current consumption (max.)(no load) 80 mA
Power-up delay (max.) 100 ms
On delay (max.) 250 µs
Off delay (max.) 250 µs
Timing 20 ms “off delay” selectable by internal switch
Analog output 0–7 V (voltage proportional to light reflected by the object)

Accessories
Description Catalog Number
Mark magnification lens XURZ01
Mark reduction lens XURZ02

Selectable Mounting Orientation Functions

1. Green LED, unit in


learning mode

2. Red LED, output state


3. Learning mode button
for mark

4. Learning mode button


for background
Optional Lenses for Focusing or Magnifying

XURZ01

XURZ02

XURU1KSMM12 Lens
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

143
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XURC Full Color and Fiber Optic Full Color Detectors
XURC Full Color and Fiber Optic Full Color Detectors

Features
• Ideal for applications such as sorting, label detection and multi-color printing
• Self-teaching with adjustable sensitivity for comparing and matching of similar colors
• Three channels with independent outputs
• Selectable response time
Photoelectric Sensors

• Synchronization option available


• Selectable 40 ms time delay
• Adjustable sensing distance
• Withstands very high vibration
• Detects up to 8 mm diameter mark
• Easy programming panel under hinged, protective cover
Operating
Circuit Output Load Current Catalog
Voltage Range Frequency
Type Type Maximum Number
Maximum
Diffuse – 40 to 60 mm (1.57 to 2.36") Nominal Sensing Range
PNP Light 12-24 Vdc 100 mA 1.2 kHz XURC3PPML2
NPN Light 12-24 Vdc 100 mA 1.2 kHz XURC3NPML2
Fiber Optic – See Fiber Optic Cables for Sensing Distances
PNP Light 12-24 Vdc 100 mA 1.2 kHz XURC4PPML2
NPN Light 12-24 Vdc 100 mA 1.2 kHz XURC4NPML2

Recommended Fiber Optics


Sensing Type System Sensing Distance Diameter of Spot Catalog Number
Convergent Diffuse 10 mm 2.5 mm XUFNL01L2
Convergent Diffuse 20 mm 5 mm XUFNL02L2
Convergent Diffuse 30 mm 8 mm XUFNL03L2
Standard Diffuse 5 mm — XUFN05321
XURC3 Standard Diffuse 4 mm — XUFS05320
Standard Thru-Beam 250 mm — XUFN12301 + XUFZ01
1.97 .27 Standard Thru-Beam 150 mm — XUFS2020 + XUFZ01
50 7
1.65 .86 For additional plastic fiber optics, see p.120.
2 x M5 42 22
(Depth 10) Application Notes
Optimal installation is achieved when the sensor is approximately 15° tilted towards the object
.99 Dia. surface. One method for establishing an angle of 15° is shown in the illustration below. When
25
2.68 the visible spot is positioned 10 mm forward of the vertical center-line to the uppermost fixing
68
3.15 hole of the detector, the face of the detector is at an angle of 15° to the target object.
80
XURC4 Since the detection is less XURC3
affected by the changes in the
sensing angle, moving direction 2.68
of the object should be as shown 68
.71
in the figure to the right. 18
.27 .21 Dia.
7 5
15
°
3.27
1.97 83
15° 50
Direction of Movement

XURC4
2.60 .40
.21 3.24 .21 .99 66 10
(2)
5 82 5 25
1.45
37 .63
16
.19
1.73

5
.98
44

25

1.18
30 Ø4.4 (3)
(4) .59
15
Dual Dimensions inches (1)
mm
(1) DIN Rail Mounting Accessory (Included)
(2) Locking Latch for Fiber Optic Cables

144
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XURC Full Color and Fiber Optic Full Color Detectors
XURC Full Color and Fiber Optic Full Color Detectors

Wiring Specifications
Mechanical
+ Operation 14° to 122° F (-10° to 50° C) q
PNP BN Temperature Range
Ue: 12 to 24 V PK (Set) Storage -22° to 158° F (-30° to -70° C)
le : 100 mA VT (Sync)
BK (OutA) Enclosure Rating IEC Type IP67 conforming to IEC 60529
WH (Out B) Vibration Amplitude 0.75 mm, f =10-55 Hz (2 hours/each of 3 axes)
GY (Out C) Shock Resistance 50 G (5 shocks/each of 3 axes)
BU –

Photoelectric Sensors
Maximum Operating Humidity 35 to 85% RH q
XURC•PPML2 at 40 mm at 50 mm at 60 mm
Spot diameter
4 mm 6 mm 8 mm
Case Aluminum
+ Enclosure Material Lens Glass
NPN BN BK (OutA)
Ue: 12 to 24 V WH (Out B) Cover Polyarylate
le : 100 mA GY (Out C) Wiring 24 AWG (0.2 mm2), Cable: vinyl rubber sleeve
PK (Set)
VT (Sync) Electrical
BU Voltage Range 12 - 24 Vdc

Voltage Limit (Including Ripple) 10 - 30 Vdc
XURC•NPML2
Voltage Drop (Across Switch, Closed State) 1.5 V
Load Current (Maximum) 100 mA
Current Consumption (Maximum) (No Load) 150 mA
Wire Definitions Power-up Delay (Maximum) 100 ms

Sleeve Time Delay programmable by switch 40 ms on falling edge


Title Function
Color Fast Normal Slow
Programmable Response Time
Brown +V Supply voltage, 12 to 24 V 0.8 ms 1.5 ms 6 ms
Blue 0V Supply ground Physical Characteristics
Pink SET Set signal Ambient Light Immunity (max.) Sunlight: 10,000 Lux, halogen light: 3000 Lux
Violet EXT External synchronous input Short Circuit Protection Yes, each Independent channel

Black OUT A Control output A


White OUT B Control output B
Grey OUT C Control output C q Ice and condensation may impede performance.
Selection of Operating Mode
4 C or C + I selector
1 Operating Status LED
Mode C
This mode is used for the detection of different colored objects.
2 Learning mode button, for memorizing reference colors
Mode C or C + I
In this mode, the detector is insensitive to varying surface finishes
3 Reference color and operating mode selector
of the object to be detected.
Selection of reference colors (SET)
Selection of operating mode
OUT 1 5 Synchronization mode selector
Tolerance mode (positions 1-5)
Internal synchronization mode (INT)
5 positions allow selection of the tolerance level to be
A B C In this mode, color detection is performed continually.
applied to the shading of the color to be detected.
External synchronization mode (EXT)
SET 2 Run mode (position S)
In this mode, color detection is synchronized with an external
This mode enables sorting by color
signal.
TOLERANCE
2 3 4 C+I External synchronization mode
1 5 4
3 A Object
S B C detected Same color
RUN
C SET
Ext. synchro
FAST T-ON
EXT (40ms) signal Different color
N 7 ON R R R R = Response time
5 Output
INT T-OFF OFF
SLOW
6 Response time mode selector
6 7 Output time delay selector (T-ON/T-OFF)
Fast mode (F), Normal mode (N), Slow mode (S)

Output time delay, internal synchronization mode Output time delay, external synchronization mode

Object Object
detected detected

ON Ext. synchro
Output signal
OFF 40 ms 40 ms
ON
Output
OFF 40 ms 40 ms

145
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Advanced Label Detection Fork, DC
XUV Advanced Label Detection Fork, DC

Features:
• Detects opaque colors on transparent background
• Self teaches to memorize label for accurate detection
• Adjustable from straight to 90 ° connection
• Two LEDs indicate three conditions: yellow - output, green - ready, red - error
Photoelectric Sensors

• Standard Nano style connector


• Durable zinc alloy enclosure
Load Operating
Circuit Output Voltage Catalog
Current Frequency
Type Mode Range Number
Max. Max.
Thru-beam - 2mm (0.079") Nominal Sensing Range – Infra-red light emission
PNP/NPN Light/Dark 12 - 24 Vdc 100 mA 10K Hz XUVK0252S

Thru-beam - 2mm (0.079") Nominal Sensing Range – Visible red/green light emission
PNP/NPN Light/Dark 12 - 24 Vdc 100 mA 10K Hz XUVK0252VS

Function table
Output state (PNP or NPN) indicator (illuminated when detector output is ON)

Thru-beam system
Mode
Absence of label in the beam Presence of label in the beam

Light switching

Dark switching

1 Applications: the infra-red transmission beam detector XUV-K0252S is suitable for the detection of all types of opaque legends; the red/
green transmission beam detector XUV-K0252VS is suitable for the detection of all types of opaque and different colors.
2 The detector incorporates “self-teaching” setting: the light or dark switching function is selected when performing the first stage of the
“self-teaching” setting procedure during set-up of the detector (see “self-teaching” setting procedure, below).

“Self-teaching” setting procedure


• Place the label to be detected in the beam of the optical fork. Press the SET button and hold
down until the green LED (2) goes out.
• When the green LED flashes, the detector has learned the label. Place the item to which
the label is affixed in the beam of the optical fork. Press the SET button and hold down until
the green LED goes out.
• When the green LED illuminates as a steady light, the “self-teaching” setting procedure is
completed and the detector is ready for operation.
1 mm

1 Yellow LED - output state indicator


4 2 Double color green/red LED - Ready/Error
3 “Self-teaching” SET button
4 Locking screw

146
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Advanced Label Detection Fork, DC
XUV Advanced Label Detection Fork, DC

.08 Specifications
2
.35 .35 .79 Mechanical

.30
7.5
9 9 20
Operation 32° to 131° F (0° to 55° C)
Temperature range
Storage -4° to 158° F (-20° to 70° C)
Enclosure rating IEC Type IP65 conforming to IEC 60068-2-27
1 2 Vibration 7 G amplitude + 1 mm (f = 10 to 42 Hz) conforming to IEC 60068-2-6
1.97
50

Shock resistance 30 G for 11 mm conforming to IEC 60068-2-7

Photoelectric Sensors
Case Zinc alloy
3.54
90
Enclosure material
3.83
97.5
Lens Glass
Ø0.17 3
Wiring Female NANO connector
Ø4.25
4 Electrical
Voltage range 12 - 24 Vdc
1.02
.71
18

26

Voltage limit (including ripple) 10 - 30 Vdc


.30
7.5

Voltage drop (across switch, closed state) 1.5 V


Load current (max.) 100 mA
.31 M8
8 Current consumption (max.)(no load) 50 mA
.71 .16 Operating frequency (max.) 10K Hz
18 4
1.02 Power-up delay (max.) 30 ms
26 On delay (max.) 100 µ
Off delay (max.) 100 µ
Physical Characteristics
XUVK0252S 880 nm
Emitter wave length:
.08 XUVK0252VS 635 nm
2
Short circuit protection yes
.35 .35 .79 Overload protection yes
.30
7.5

9 9 20 Protective Circuitry
Reverse polarity
yes
protection

1 2
1.97
50

3.54
90

Ø0.17 3
Ø4.25
4
M8

1.02
.71
18

26
.31
8

.71 .16
18 4
1.02 .30
26 7.5

1 Green/Red LED = Ready/Error


2 Yellow LED = Output
3 SET button
4 Locking screw

Connector
NPN output 2 4 PNP output

1 3
+ –

Dual Dimensions inches


mm

Connector Cables (M8 or S suffix)


XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
For additional cable options and lengths see p. 518

147
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Self-Contained Fork Type (30 mm)
Economy, DC
XUV Self-Contained Fork Type (30 mm) / Economy, DC

Features:
• Self contained electronics eliminates the need for a separate amplifier
• Ideal for detection of small parts at fast speeds
• 360° LED output indicator
• ABS enclosure
Photoelectric Sensors

• CE mark
Voltage Range Load Current Operating Catalog
Circuit Type Output Mode Connection
Max Max Frequency Number
Thru-Beam – 30mm (1.18") Nominal Sensing Range
PNP Dark 19-38 Vdc 150 mA 1000 Hz 2m (6.6’) cable XUVH0312
NPN Dark 19-38 Vdc 150 mA 1000 Hz 2m (6.6’) cable XUVJ0312

Function Table
Thru-Beam System
Function
No object present in the beam Object present in the beam

Output state (PNP) LED


(illuminated when Dark Mode
detector output is ON)

Detection Curve
.06 (± .01) in.
1.5 (± 0.3) mm

148
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Self-Contained Fork Type (30 mm)
Economy, DC
XUV Self-Contained Fork Type (30 mm) / Economy, DC

Wiring Specifications
Mechanical
Dark mode (no object present) Operating 23° to 131° F (-5° to 55° C)
Temperature Range
Storage - 4° to 158° F (- 20° to 70° C)
PNP output Enclosure Rating IEC Type IP54 conforming to IEC 60529
Case PC/ABS
BN Enclosure Material Lens PMMA
Cable PVC

Photoelectric Sensors
BK
Vibration resistance (IEC 60068-2-6) 7 gn, amplitude ± 1mm (f = 42 Hz to 150 Hz)
BU
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
LED indicator type 360° ring LED: shows output status
Connection Cable 5 mm diameter cable, 3 x 0.5 mm2
Electrical
Voltage Limits (including ripple) 19 – 38 Vdc
Voltage Drop (across switch) closed state max. 1.5 V
Current consumption (no load) Max. 20 mA
Load Current Max. 150 mA
Max. Operating frequency 1000 Hz.
On delay max. 500 µs
Off delay max 500 µs
Power-up delay max 30 ms
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
Physical Characteristics
Ambient light immunity 1000 Lux.
Emitter wave length 880 nm

2.28 = .55 =
58 14
1.18
30
(1)

.43 in. dia.


11 mm dia. 1.18
.10 30
2.7 2.68
(3) 2.03 (2)
68
.20" dia 52
5 mm dia.
1.10
.72 .79 28
18 20
.08
2 .20 .26
.20 .08
5 7
5 2
1.85
47

(1) Optical Axis


(2) LED
Dual Dimensions inches
mm (3) 360° Diffuser

149
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUVF Dynamic Fork Type – DC
XUVF Dynamic Fork Type - DC

XUVF sensors detect the dynamic flow of all types of objects (both metal or plastic, and of any
color or shape)
Fork body detects moving targets for use in applications such as:
• Parts ejection, as in air compression transfer of parts
• Counting parts traveling down a chute
Photoelectric Sensors

• Continuous feeding of thread, for the detection of breakage

Features:
• Detects targets falling at a minimum of 10 cm per second, maximum 15 meters per second
• Off-delay (reset) timer function: 0 to 5 seconds
• Sensitivity and timing adjustment by separate potentiometers
• Green output LED and red alarm LED for clear indications
• Sturdy aluminum body and M8 (Nano) connector
Voltage Load Operating
Circuit Output Catalog
Range Current Frequency
Type Type Number
Max. Max. Max.
Thru Beam - 30mm x 30mm Fork – Minimum Target 2mm – Nano Style Connector
PNP/NPN Light/Dark 18 - 30 Vdc 100 mA 500 Hz XUVF30M8

Thru Beam - 60mm x60mm Fork – Minimum Target 2mm – Nano Style Connector
PNP/NPN Light/Dark 18 - 30 Vdc 100 mA 500 Hz XUVF60M8

5.16
131
Dual Dimensions inches .63
mm
2.36 16
60
4.25
108
1.18 .63
30 16
2.75
(R) (R) (E) 70
(E) 1.41
36

.13 .13
3.5 3.5
M8 M8
.86 2xØ4.2 .86 2xØ4.2
22 22
.59
15

Sensitivity
.59 T imer off
15
delay 0 to 5s.
3.38
Sensitivity 86
T imer off
1.97 LEDs
50 delay 0 to 5s.
.45 .45 E=Emitter
11.6 LEDs 11.6 R=Receiver

XUVF30M8 XUVF60M8

150
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUVF Dynamic Fork Type – DC
XUVF Dynamic Fork Type - DC

Wiring Specifications
Connector Mechanical
Alarm Output Operation 32° to 140° F (0° to 60° C)
Temperature range
2 4 Storage -4° to 176° F (-20° to 80° C)
1 (+) 3 (–) Enclosure rating IEC Type IP65 conforming to IEC 60529
Vibration 25 G amplitude ± 2 mm (f =10 to 55 Hz)
Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27

Photoelectric Sensors
PNP 1 +
Case Aluminum
4 Enclosure material
Output Lenses Polycarbonate
2 Alarm Connection M8 (Nano Style 4 Pin DC) connector
3 – Minimum target size 2mm diameter
Emission type Infrared
Sunlight: 4000 lux
Ambient Immunity (max)
NPN 1 + Incandescent: 400 lux
4 Output Electrical
2 Alarm Voltage limits (including ripple) 18–30 Vdc (reverse polarity protected)
3 – Voltage drop (across switch, closed state) 2V
Current consumption (max.)(no load) 120 mA
Power-up delay (max.) 100 ms
On delay (max.) 1 ms
Off delay (max.) 1 ms
Timing Off-delay (reset): 0 to 5 seconds
Two LED Indicators Output, alarm, supply failure and short circuit
Minimum Target Speed 10 cm/s @ 2 mm Dia.
Maximum Target Speed 15 cm/s @ 2 mm Dia.

Output
on GR

Alarm
on RD

Detection of parts passing through fork: green LED indicates output. If parts are lodged inside fork, red LED indicates alarm.

Connector Cables (M8 or S suffix)


XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
For additional cable options and lengths see p. 518

151
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUVF Dynamic Window Type – DC
XUVF Dynamic Window Type - DC

XUVF sensors detect the dynamic flow of all types of objects (both metal and plastic, and of
any color or shape).
Window body detects moving targets for use in applications such as:
• Parts ejection, as in air compression transfer of parts
• Counting parts traveling down a chute
Photoelectric Sensors

• Continuous feeding of thread, for the detection of breakage

Features:
• Detects targets falling at a minimum of 10 cm per second, maximum 15 meters per second
• Off-delay (reset) timer function: 0 to 5 seconds
• Sensitivity and timing adjustment by separate potentiometers
• Green output LED and red alarm LED for clear indications
• Sturdy aluminum body and M12 (Micro) connector
Voltage Load Operating
Circuit Output Catalog
Range Current Frequency
Type Type Number
Max. Max. Max.
Thru Beam - 200mm x 120mm Window – Minimum Target 4mm – Micro Style Connector
PNP/NPN Light/Dark 18–30 Vdc 100 mA 500 Hz XUVF120M12

Thru Beam - 200mm x 180mm Window – Minimum Target 4mm – Micro Style Connector
PNP/NPN Light/Dark 18–30 Vdc 100 mA 500 Hz XUVF180M12

Thru Beam - 200mm x 250mm Window – Minimum Target 4mm – Micro Style Connector
PNP/NPN Light/Dark 18–30 Vdc 100 mA 500 Hz XUVF250M12

3.34 4xØ5 1.97


85 50

Sensitivity adjustment
potentiometer

Time delay adjustment


potentiometer (0–5 sec.)
9.05
a1 230 Red LED: Alarm
Green LED: Output

7.87 8.76 In the event of a supply


200 223 malfunction, the red
LED flashes.

In the event of a short-


circuit on the output,
both the red and green
(R) (E) LEDs flash.

.86
22

2.36 .98 .98


60 25 25 E=Emitter
a
R=Receiver
M12

Dimensions
a a1
Dual Dimensions inches
IN mm IN mm mm

XUVF120M12 8.07 205 4.72 120


XUVF180M12 10.43 265 7.09 180
XUVF250M12 13.19 335 9.84 250

152
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUVF Dynamic Window Type – DC
XUVF Dynamic Window Type - DC

Wiring Specifications
Connector Mechanical
1 ( +) Temperature range Operation 32° to 140° F (0° to 60° C)

2 4 Storage -4° to 176° F (-20° to 80° C)


Alarm Output Enclosure rating
IEC Type IP65 conforming to IEC 60529

3 ( –) Vibration 25 G amplitude ± 2 mm (f =10 to 55 Hz)


Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27

Photoelectric Sensors
PNP 1 + Case Aluminum
Enclosure material
4 Output Lenses Polycarbonate
2 Connection M12 Micro Style 4 pin connector
Alarm
3 Minimum target size 4 mm diameter

Emission type Infrared
Sunlight: 4000 lux
Ambient Immunity (max)
NPN 1 + Incandescent: 400 lux

4 Output Electrical
Voltage limits (including ripple) 18–30 Vdc (reverse polarity protected)
2 Alarm
Voltage drop (across switch, closed state) 2V
3 –
Current consumption (max.)(no load) 400 mA
Power-up delay (max.) 100 ms
On delay (max.) 1 ms
Off delay (max.) 1 ms
Timing Off-delay (reset): 0 to 5 seconds
LED Indicators Output, alarm, supply failure and short circuit
Minimum Target Speed 10 cm/s @ 4 mm Dia.
Maximum Target Speed 15 cm/s @ 4 mm Dia.

Detection of parts passing through window: green LED indicates output. If parts are lodged inside window, red LED indicates alarm,
but sensing operation is not affected.

Connector Cables (M12 or D suffix)


XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518

153
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUZ Power Supply/Converter, AC to DC
ZUZ Power Supply/Converter, AC to DC

Features:
• AC supply, DC output
• Two channel amplifier, for PNP Solid State
• Three LED indicators: Power, Output 1, Output 2
• N.O. and N.C. output per channel
Photoelectric Sensors

• 40 ms Time delay optional


Output Operating
Circuit Output Voltage Catalog
Voltage Frequency
Type Mode Range Number
Max. Max. Output
AC, Relay Output N.O./N.C. 100 to 240 Vac 30 Vdc 50 Hz XUZF02

Mounting rail fixing


3.6

.29
7.3
91.5
2.7 1.77
68.5 45
+
.59
15

1.51

1.44
36.5
38.5
– .75 .75

3.09
78.5
63.5
2.5

19.2 19.2

.94

1.77
24

45
.78
4.5
Dual Dimensions inches
mm

154
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUZ Power Supply/Converter, AC to DC
XUZ Power Supply/Converter, AC to DC

Specifications
Mechanical
Storage -22° F to 158° F (-30° C to 70° C)
Temperature range
Operation 14° F to 131° F (-10° C to 55° C)
Enclosure rating IEC Type IP20 conforming to IEC 60529
Vibration 7 G +/- 1.5 mm F: 10-55 Hz
Shock resistance 10 G at 3 axes / 3 times

Photoelectric Sensors
Supply: green
LED indicator type Output - channel 1: yellow
Output - channel 2: yellow
Enclosure material ABS
Electrical
Voltage range 100-240 Vac
Voltage on Relay Output 264 Vac, 30 Vdc
Current consumption (max.)(no load) 10 mA
Operating frequency (max.) 50 Hz
Power-up delay (max.) 20 ms
On delay (max.) .1 ms
Time delay 40 ms (fixed)
Relay load current 1A

Terminals
1-2 Supply AC
3 N.C. contact output, channel 1
9 11 13 15 17 19 4 N.C. contact output, channel 2
5 Common output, channel 1
6 Common output, channel 2
7 N.O. contact output, channel 1
8 N.O. contact output, channel 2
9 Supply DC 12 V (–) for detector controlling channel 1
11 Connection terminal for output of detector controlling channel 1
13 Supply DC 12 V (+) for detector controlling channel 1
D1 D2 D3 15 Supply DC 12 V (–) for detector controlling channel 2
17 Connection terminal for output of detector controlling channel 2
19 Supply DC 12 V (+) for detector controlling channel 2

LED indicators
2 4 6 8
D1 Supply (green)
D2 Output, channel 1 (yellow)
D3 Output, channel 2 (yellow)
1 3 5 7

Connections
BN +
11 13 15 17 19

OUT2 OUT1
PNP
8

BK
IN2
BU
5
6

-
BN
+
PNP
3
4

BK
IN1
2

BU
-
9

AC

155
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Reflectors
Specifications
Reflectors / Specifications

0.3" Corner cube reflectors used with retroreflective photoelectric sensors provide a high degree of
reliability since they return the light to its source even if the reflector and the switch are skewed
quite significantly in respect to each other. Corner cube reflectors also have the only reflective
surface that works with polarized photoelectric sensors. The nominal sensing distance for every
retroreflective switch model in this catalog was established using a 3" RF30 reflector. Smaller

3"
reflectors will result in shorter sensing distances. They are used to detect smaller targets
comparable with their dimension. The standard reflectors present a “blind spot” at about 10%
Photoelectric Sensors

of the sensing distance. Special reflectors XUZC24/50 are designed to eliminate this
inconvenience and allow the reflector to come as close as touching the sensor lenses.
RF30
RF30 and RF20 models can be mounted via a bolt. RF10 models can be mounted using a bezel
0.3"
or plate (not provided) or using its own adhesive tape. Rectangular shaped reflectors increase
sensing precision. They are also easier to mount side-by-side to increase the reflective surface.
Reflective tape can be used for covering unusually shaped targets. It is not a corner cube
reflector. Only Super reflective tape is a corner cube reflector. It can also be used with polarized
2"

retroreflective sensors.

Reflectors
RF20 Description Reflectivity Temperature Rating Catalog Number
3" diameter, acrylic lens 4000X 150° F (65° C) RF30
2" diameter, acrylic lens 4000X 150° F (65° C) RF20
1" diameter, acrylic lens 4000X 150° F (65° C) RF10
1"

3.25" x 1.5", acrylic lens (orange) 4000X 150° F (65° C) RF13


4" x 4" diameter, acrylic lens 4000X 150° F (65° C) XUZC100
1.3" x 1.1" close proximity – acrylic 6000X 150° F (65° C) XUZC24a
RF10 2" x 2" close proximity – acrylic 6000X 150° F (65° C) XUZC50a
0.63" (16 mm) 4000X 150° F (65° C) XUZC16
0.83" (21 mm) 4000X 150° F (65° C) XUZC21
1.22" (31 mm) 4000X 150° F (65° C) XUZC31
1"

1.53" (39 mm) 4000X 150° F (65° C) XUZC39


3.15" (80 mm) 4000X 150° F (65° C) XUZC80
3.25"
a Note: XUZ C24/50 reflectors must always be mounted in the vertical plane with respect to the optical axis of the switch.
RF13
Retroreflective Tape
Typical Luminance Factor➀ Catalog
Description Temperature
(Perpendicular Reading) Number
Photoelectric grade sheeting with adhesive backing➁
3" wide, 1' long➂ 200X 200° F (93.4° C) RF7590
High intensity sheeting with adhesive backing - vinyl sealed➁
.82
21

3" wide, 1' long➂ 670X 150° F (65.6° C) RF3870


1.30

High gain sheeting with adhesive backing - porous surface➁


33

2" wide, 1' long➂ 900X 175° F (79.5° C) RF7610

Super Reflective Tape – corner cube type, adhesive backing


Can be used with polarized retroreflective systems
.94 Typical Luminance Factor➀
24 Description Temperature Catalog Number
= = (Perpendicular Reading)
1.14 1" wide, 3’ long 2000X 140° F (60° C) XUZB11
29 1" wide, 16' long 2000X 140° F (60° C) XUZB15
XUZC24 ➀ Expressed as times brighter than a perfectly diffusing white surface.
➁ Not suitable for polarized models.
➂ Also available in 10’, 50’ and 100’ lengths.
1.37
35 2xR1 Dual Dimensions inches
4xR5 mm
3.5 3.1
91 80
100

2.0
59
1.85
47
2.83
72

2.36

2.71
60

69

100 2.8
8 73 XUZB• XUZC••
XUZC100 XUZD15 4xØ4.5 4xR2.25 .31 .13
8 3.5 .31
XUZC50 8

156
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Accessories
Accessories

Description For Use With Catalog Number

Covers
Protective Cover XUJ, XUE XUZD25
Potentiometer Cover XUJ XUJZ01
XUJZ01 XUZD15
Reflector Cover XUZC XUZD15
Transparent Cover XUD XUDZ02
XUZD25

Photoelectric Sensors
Transparent Cover XUV XUVZ02
Alignment Tool XUJ, XUE (Thru-beam) XUZD09
Lens Hood XUE XUZD02
Bottom Entry Conduit Cover (9mm) XUJ XUJZ09

Masks
XUZD09 Mask: 10cm/40cm Range, 0.5mm/1mm Diameter Classic XUM (Thru-beam except XUML) XUMZ01
XUVZ02
Mask: 0.9m/1.5m Range, 1.5mm/2mm Diameter Classic XUM (Thru-beam except XUML) XUMZ03
Mask: 1M Range, 6mm Diameter XUJ (Thru-beam) XUJZ02

Mirrors
90 ° Mirror Adaptor XU 18mm (Retroreflective and Diffuse) XUBZ01
XUDZ02 90 ° Mirror Adaptor XU 18 mm (Thru-beam) XUBZ02

Mounting Hardware
XUZD02 Mounting Bracket (Plastic) XUML•S XUZA46
XULZ41 a
Mounting Bracket (Metal) XUL XULZ43
XULZ43
XUMZ0k Mounting Bracket (Metal) XUJ XUZA41
Adjustable Mounting Bracket (Metal) XUJ XUZA43
XUJZ09 Mounting Bracket (Metal) XUE XUZA44
Mounting Bracket (Metal) XUM XUZA47
XUBZ01 Mounting Bracket (Metal) XUJL, XUJB XUZA49
Mounting Bracket (Metal) XU 18 mm, XUB XUZA118
XUJZ02
Swivel Mounting Bracket (Plastic) XU 18 mm, XUB XUZA218

XUBZ02 Precision adjustment mounting bracket (micro metric precision) XU2 18 mm laser, XUB XUZA318
Mounting Bracket (Plastic) XUA XSAZ108
Mounting Bracket (Plastic) XUA XSZB108
Mounting Bracket (Plastic) XU 18 mm, XUB XSAZ118
Mounting Bracket (Plastic) XU 18 mm, XUB XSZB118
Mounting Nuts (Plastic) XU 18 mm, XUB XSAZ318
Swivel mounting bracket (Plastic) XUC XSZSB30
a See p. 170 for mounting positions of the XULZ41.

XULZ41 XUZA41 XUZA43

XSAZ1•• XSZB1••
XUZA46 XUZA44
XSAZ1kk
XSA a b b1 c d d1 dia d2 dia d3 dia f g g1
Z108 23.5/.92 14.2/.56 16.7/.66 10/.39 8/.31 8.5.33 2/0.7 3/.12 13/.51 16/.63 5/.19
Z118 41/1.61 30/1.18 33/1.3 20/.79 18/.71 18.5/.72 3.9/.15 6/.23 29/1.14 30/1.18 8/.31
Z130 53/2.06 39.5/1.55 42.5/1.67 20/.79 21.5/.85 30./1.2 3.9/.15 5/.19 39/1.53 40/1.57 10/.39

XSZBkkk
XUZA318 XUZA49 XSZ a a1 b b1 b2 dia
B108 19.9/.78 14.5/.57 14/.55 12.5/.49 7.5/.29 8/.31
B118 26/1.02 15.7/.62 22/.86 20.1/.79 11.5/.45 18/.71
B130 39/1.53 21.7/.85 35.5/1.40 31/1.22 18.5/.73 30/1.18

XUZA118 XUZA218 XUZA47

157
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Accessories
Accessories

1.89
48 2x¯7

0.63

=
16

3.46
2.83

88
72
(1)
¯4,2

133.5
6.26

=
101.5
4.0
Photoelectric Sensors

5.87
10¡ 10¡

149
3.15 2.87 5xØ8
73
2.6

80
66

¯4 ¯6 3.59
10¡10¡

91
0.87

XUZD15
0.63
22

0.63
16

16
¯6

= =
3.28 1.73 1.73
83.4 5.04É5.32 44 44
128É135
XUZD25
Ø7

1.06
27
2.75 1.45
9.45 70 37
240
XUZD09 0.10
2.5 Ø18.5

1.38
35
1.69
2.32

43
59

1.10 = =
12.7 28 1.97
(0.50) 50
M30x1 0.59
15
0.039

0.25
1

6.5
0.79 0.90 6.34
20 1.3 23

0.39
= =
(0.25)

10

0.65
16.5
33
27.9
XUZD0• (1.10) 20.3 0.25 0.79
6.5 20
(0.80)
14.2 XUZA118
4x¯4.2 0.27 (0.56)
7 0.39 1.77 Ø18.5
29.2 10 45
=

(1.15)
=

1.57
40

15
1.18
30

28.7 50.8

0.98
=

2.64

25
(1.13)
67

(2.00)
0.19
5
=

2.16
66.7 55
4x¯4.2
(2.62)
0.31 0.94 0.31
0.27
7

8 = 24 = 8
0.25
6.5

= = = 1.18 = XSZSB30
= 1.18 = 30
1.57

1.06
27
19.5
30
0.76
40
1.57 1.65
40 42 15
XUZA43
XUZA218
1.51 Ø
38.3
b

Ød1
b1
b2

0.14
Dual Dimensions inches
2.5 b1

3.5
b

mm a1
f
0.98

(1) a
Ød3
Ød2
= = = =
c G G1 0.16 0.86 0.31
a 4 22 8

XSAZ1kk XSZB

XSA a b b1 c d d1 dia d2 dia d3 dia f g g1 XSZ a a1 b b1 b2 dia


Z108 23.5/.92 14.2/.56 16.7/.66 10/.39 8/.31 8.5.33 2/0.7 3/.12 13/.51 16/.63 5/.19 B108 19.9/.78 14.5/.57 14/.55 12.5/.49 7.5/.29 8/.31

Z118 41/1.61 30/1.18 33/1.3 20/.79 18/.71 18.5/.72 3.9/.15 6/.23 29/1.14 30/1.18 8/.31 B118 26/1.02 15.7/.62 22/.86 20.1/.79 11.5/.45 18/.71

Z130 53/2.06 39.5/1.55 42.5/1.67 20/.79 21.5/.85 30./1.2 3.9/.15 5/.19 39/1.53 40/1.57 10/.39 B130 39/1.53 21.7/.85 35.5/1.40 31/1.22 18.5/.73 30/1.18

158
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
3-D Accessories
3-D Accessories

Description For Use With Catalog Number


3-D mounting kit for 18mm cylindrical XUB, XU18, XUZC50 XUZB2003
3-d mounting kit for miniature rectangular XUM, XUZC50 XUZM2003
3-D mounting kit for subcompact (50x50) XUK, XUZC50 XUZK2003
3-D mounting kit for compact rectangular XUX, XUZC50 XUZX2003
Protective 3-D mounting kit for XUM XUM XUZM2004
Protective 3-D mounting kit for XUK XUK XUZK2004
Protective 3-D mounting kit for XUX XUX XUZX2004

Photoelectric Sensors
M12 Stem (75mm usable length) XUZB, XUZM, XUZK, XUZX XUZ2001
3-D mounting base XUZ2001 XUZ2003

XUZX2004 XUZX2003 XUZK2004 XUZK2003

XUZB2003 XUZM2003 XUZM2004

XUZ2001

XUZ2003

159
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
3-D Accessories
Dimensions
3-D Accessories, Dimensions

XUZK2003 XUZK2004 XUZX2003

2.3 2.36 1.9


59.25 60 50 0.64
1.57 1.59 1.57
16.49
40.02 40.5 40
56.35

2.36
40 2.36

60
2.2

60
40.02

1.57
1.57

100
3.9

1.3
Photoelectric Sensors

2.8

33
73
M4 ∅0.21
0.18 5.5
0.17
4.5 ∅
4.5 ∅ 0.22
45 2.48

5.5
63
1.77
1.1
28

‡ 0.2
1.3
5
33

XUZX2004 XUZB2003 XUZM2003 XUZM2004


2.87 0.22 1.77 1.14 1.49
1.59
73 1.4 5.75 45 38
29 0.76 40.5 0.51
∅ 0.72 M4 36 0.86 13

1.57
19.5

0.98 40
18.5 22.0

42 1.3
33

0.98
25
1.65

25
1.3
33
3.9
99

1.6
40

M5 M4 M3 M3
1.59
40.5
1.63
41.5

XUZ2003 Component XUZ2001


0.76
19.5
1.1
28
0.76
19.5

1.4
36
0.47
∅ 0.25 ‡ 0.57 12
120
4.7

∅ 0.5 6.5 14.5


1.77
0.07

45

12.5
1.9

1.57
0.9 40
23
0.9
23

Dual Dimensions inches


mm

160
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUML, XUM Classic and XUL Sensing Patterns
ing Patterns

XUML
Thru-beam Retroreflective Proximity Diffuse
cm cm 1
6 6 cm
2 2
6 mm
T 2 2 1
4 R
4

Photoelectric Sensors
8 m 2 4 m 0.1 0.2 0.4 m
-2 0.2
-2
-4 -4 -2
-6 Su 8m -6 (1) Su 2m -1
Su 0.4 m
(2) Su 4m
10 x 10 cm target
(1) Polarized (2) Infra-red (std.) 1 white 90%
XUZC50 reflector 2 grey 18%

XUM Classic
Thru-beam system Reflex system Diffuse system (example 0.7 m)
cm cm
6 6 cm
4 4 2
Dia. 6 mm 1
E 2 R m 2 m m
7 0.2 2 3 0.2 0.4 0.7
-2 -2 Su 2 m (polarized) -1 target
-4 -4 -2 20 x 20 cm
Su 7m 6'
-6 -6 white 90%
23' Su 3 m (infrared) Su 0.7 m grey 18%
9' 2.29'

XUL
Thru-beam system Polarized reflex system Diffuse system Diffuse system with
background suppression
cm cm
mm mm
10 10
10 10 8 8
6 6
5 Dia.16 mm 5 4 4
m 2 2 m

0.2 -2 0.1 0.3 0.7 m -2 0.1 0.2 0.25 m


-5 -5 4 6 -4 -4
-6 -6
-10 -10 -8 (1) -8
Su 8m Su 4m -10 Su 0.7m -10 Su 0.25 m
26' 15' 2' 1'
target target white 90%
20 x 20 cm (1) white 90% 20 x 20 cm black 6%

161
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJL, XUJ and XUE Sensing Patterns
XUJL, XUJ and XUE Sensing Patterns

XUJL
Thru-beam system Retroreflective system Polarized retroreflective system
cm
10 cm cm
6 6
6
20 mm 4 4
2 2 2
0 0 0
Photoelectric Sensors

20 m -2 10 m -2 8 m
-2
-6 -6 -6
-4 -4
-10 Su 15 m Su 8m Su ≤ 6 m

XUJ
Thru-beam system Retroreflective system Diffuse system (side approach recommended)

10 dia. of beam dia. of beam dia. of beam


10
8 cm cm 8 cm
6 6 6
4 dia. 20 mm 4 4
2 m 2 m 2 m
0 0 0
-2
2 12 2 7 -2 0.05 0.6 1.2
-4 -4 -4 target
-6 -6 -6
-8 -8 20 x 20 cm
(1)
-10 Su 10 m Su 6 m -10 (2) (1) white 90%
Su 0.7 m
Su 1.2 m (2) black 6 %

XUE
Thru-beam system Retroreflective system Diffuse system (side approach recommended)

Approach zone, yellow LED on Approach zone, yellow LED on


dia. of beam Operating zone, green LED on Operating zone, green LED on
cm
30 dia. of beam
dia. of beam cm
20 9 cm
dia. 40 mm 6 2
m 3 m 1 m
0
30 40 -3 0,5
8 10
12 -1 0.0 0. 1
target
-6 -2 5 4
-20 (2) 20 x 20 cm
-30 Su 8 m (polarized) (1)
Su 30 m Su 10 m Su 1.5 m (1) white 90%
(2) grey 18%
XUE•30 XUE•10

Background Suppression XUE

4
D (cm)
8
10 20 30 40 50 60 70 80 90 100
4

8
cm

Adjustment set at 75 cm Adjustment set at 75 cm


using a matt black target, using a matt white target,
reflection coefficient 6% reflection coefficient 90%
Target moving perpendicular to vertical axis

162
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFN and XUFS Sensing Patterns
XUFN and XUFS Sensing Patterns

Thru-beam system

XUFN12301 XUFN12311 XUFN10302 XUFNZ01 XUFN02801 XUFS2020

20 mm
mm mm mm mm mm

mm

Su ≤ 30 mm

Photoelectric Sensors
Su
20
(1)
120 10
10
120
20 200
mm
120 mm 100

100 mm
120 mm

4 2 - -

Su ≤ 200 mm
15
dia. of 2 4
60 beam
60 cm 100
50
Su

Su
6 3 -3 -6
Su

dia. of
beam
cm cm cm
cm
4 2 -2 -4 4 2 -2 -4
4 2 -2 -4
dia. of dia. of 6 3 -3 -6
dia. of beam beam dia. of
beam
beam

XUFN10312 XUFN35301 XUFN35311 XUFZ910, Z920 XUFZ911, Z921

mm mm mm
35 mm

35 mm

mm mm
Su

200 300
Su

Su ≤ 300 mm
25

Su ≤ 200 mm
100 25
100 mm

cm
cm 100 150
4 2 -2 -4
50
dia. of 4 2 -2 -4
beam dia. of
Su

beam
cm cm
cm 6 3 -3 -6 8 4 -4 -8
4 2 -2 -4 dia. of dia. of
dia. of beam beam
beam

Brackets: XUFZ03, Z04 or Z05 Brackets: XUFZ03, Z04 or Z05 Brackets: XUFZ13, Z14 or Z15 Brackets: XUFZ13, Z14 or Z15
Cable: XUFZ910 or Z920 Cable: XUFZ911 or Z921 Cable: XUFZ910 or Z920 Cable: XUFZ911 or Z921

mm mm
mm mm
Su

Su

dia. 5 mm dia. 5 mm
Su

Su

dia. 1 mm dia. 1.4 mm

cm 6 -6 cm 6 -6
cm 2 -2 cm 4 -4
dia. of dia. of
dia. of dia. of beam beam
beam beam

NOTE: Su = usable sensing distance

163
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN, XUFS, and XUE Sensing Patterns
XUFN, XUFS, and XUE Sensing Patterns

Proximity diffuse system


XUFN05312 XUFN15322 XUFN01321 XUFN04331 XUDZ01
XUFN05323 XUFN15332 XUFN01331 XUFN02323
XUFN05331

mm

Su ≤ 15 mm

Su ≤ 12 mm

Su ≤ 20 mm
Su ≤ 4 mm
Photoelectric Sensors

1
mm mm mm mm
50
1 1 2 1
40
15 20
Su ≤ 50 mm

10 10 2
30 10

20 mm 4 2 -2 -4 mm 4 2 -2 -4 mm 4 2 -2 -4 mm 4 2 -2 -4

10 dia. of dia. of dia. of dia. of


beam beam beam beam

mm 6 4 2 -2 -4 -6
dia. of
beam

1 Target 30 x 30 cm, white 90%


2 Target 15 x 15 cm, white 90%
Su = usable sensing distance

XUFS0520

mm

70
50
Su ≤ 70 mm

cm
2 1 -1 -2
dia. of
beam

164
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUML and XUM Dimensions
XUML and XUM Dimensions

XUML Classic
Cable version

27 10 (4) (1) 12 (2) XUZA47 bracket Bra cket footprint

4.5
(3) 15

7.5 4

Photoelectric Sensors
3.5

18
25.5
34

41
3.2

17.5
8.3 (1) Oblo ng hole 3 x 4 mm

5
(2) LEDs
(1) (3) Oblo ng hole 8.2 x 3.2 mm
4 mm dia. 5 (4) Sensitivity potentiometer

Connector version

XUZA46 bracket
27 12 (3) 12 (2)

5.5
3.5

(1)
4
25.5

25.5
34

37
(1)
17.5
5

(1) Oblong hole 3 x 4 mm


12 7 (2) LEDs
19 (3) Sensitivity potentiometer

XUM Classic
Sensitivity Sensitivity
adjustment adjustment .39
.86
.94 22 10
LED 24
1.26
32

.31

1.45
8

37
1.00
25.5

Dia. 4.5
2 elongated
Dia. 4.5 Dual Dimensions inches
holes dia. 3 x 4 mm

165
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUL, XUJL and XUJ Dimensions
XUL, XUJL and XUJ Dimensions

XUL

1.77 1.37 sensitivity .70 LED Mounting bracket


45 35 potentiometer 18
(diffuse model) 20¡
Optical axis
equivalent to R .57
DC

.27
7
AC XUG A 14.5

.43
11
Photoelectric Sensors

10¡ 10¡

2.75
dia.

70

1.18
3mm B

30
1.5
39
2.14
54.5

1.10
28
B

1.10*

3.15
80
28
6mm 6mm
dia. dia.
A 10¡

.17
4.5
.55
14
.39
10

.47
12
10¡ A : 1 elongated hole, dia. 4.1 x 10 mm
10¡ 1.59
B : 1 elongated hole, dia. 3.1 x 10 mm
1.18
.81 40.5
30
20.6 20.6 *Front mounting (3mm dia.
1.18 .81 screws and inserts supplied)
30

XUJLM
XUJLM• • • • XUJLM• • • • P9 Front face Mounting bracket
XUZA49
0.1 2.4 0.1 2.6 1.07
1.1
2.6 (7) 61 2.6 (7) 66 (4) (8) 27.2
28
(4) 0.4
(9)
97.50

10
0.51

3.84

0.25 0.94 0.5 0.47


R
13

6.5 24 14 12
2.46 (62.5)
1.0 1.0 1.0 1.0 T
0.4 0.4 1.0 1.0

0.4 0.4 1.0 1.0


10 10 25 25

10 10 25 25

25 25 25 25 (10)
(1)
2.5 (62.5)

30 (6)

0.63 0.63
3.3
85
1.2

16 16
30.5
1.2

(5) 0.5
0.47 0.55 (3) 0.25 0.47 0.55 (3) 0.5 0.5 12.8
12 (2) 14 3.3 6.25 12 (2) 14 2.2 12.7 2.17 12.8
83.6 57 55.2

Notes
(1) cable gland – P11 (0.5" NPT standard) (5) cable gland – P9 (bottom entry option) (9) 2 oblong holes 6.5 dia. x 16.5
(2) 2 oblong holes 6.5 dia. x 10 mm (6) front mounting (4 mm screws and nuts incl.) (10) 1 oblong hole 6.5 dia. x 30.5
(3) 1 oblong hole 6.5 dia. x 24 mm (7) on polarized models only
(4) 8 oblong holes 4.2 dia. x 10 mm (8) ON/OFF LED – yellow

XUJ
2.40 .10 2.60
1.35

1.07
.05

61 LED LED sensitivity and 2.6 LED LED 66 sensitivity and 27.2
time delay time delay
potentiometers polarized potentiometers
models
only
3.34

R
85
.51
13

.10
2.6 E
A
1.18*
1.18

1.18

98.85
3.89
30

30
30
1.20
30.5

2.46
62.5
.66

17

B B
17

C
10¡10¡ 10¡ 10¡ 10 10
.39 .78 .35 .39 .78 .35 1.28
10 20 9 10¡ 20 9 32.6
2.88 2.24
75.9 57
* Front mounting
A : 1/2 " NPT Note : Receiver (R) and Emitter (E) (∅ 4 screws and inserts supplied)
B : 1 elongated hole ∅ 4.2 x 14 are reversed on diffuse models
C : CM8 / PG9 cable gland with background suppression Dual Dimensions inches
mm

166
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUE and XUD Classic Dimensions
XUE and XUD Dimensions

XUE
XUE.300..., XUE.10031 XUE.080319 Mounting bracket Lens hood for XUE/XUR
2.79 .43 1.31 XUZD01/D02
71 11 35.5 13¡
(3)

2.52
64

Photoelectric Sensors
22.3
.87

1.69
2.32
100
3.9

43
59
T

1.97
50
102.5 dia.
4.74

LED 6
(2)

.15
2.79
15 15

7
71
10¡ 10¡

1.28
.78 .90
34
20 23
1.31
35.5

1.30

25.5
.94
(1) 33

.39 1.97 .39 .80 (1) 1/2 " NPT


9.9 50 9.9 20.5 (2) 1 elongated hole dia. 6 x 23
3.22 1.71
82 (3) 1 elongated hole dia. 6 x 18
43.5

XUD Classic
.19 2.00 Mounting Plate
5 51
.26
6.6

.28
7.3
1.10

R
28
.03
7.4

1.46
37.3
1.26

E dia. 4.5
32
13.3

14.2
.52

.55
1.18 .27 .19 .43
.55 2 x dia. 3.2 5 111.06
14.2 30 7 3.5x5.2 3.5x5.2
Omega rail 27
mounting

Dual Dimensions inches


mm

167
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN and XUFS Dimensions
XUFN and XUFS Dimensions

Thru-beam (pairs)

L = 59.0 Ø0.08
Photoelectric Sensors

1500 2.2

0.7
Ø0.08 18
2.2
.11

.11

.11
3

3
L = 19.7 Ø0.04
M 2.6 dia. 0.06 M 2.6 dia. 0.06 M 2.6 dia. 0.03 500 1
x 0.45

0.39
1.5 x 0.45 1.5 x 0.45 0.8
.59 .19 3.5

.59 .19 3.5


15 5 90

15 5 90

3.5

10
.47
12

90
.47

.47
12

12

M4 M3 M0.11x0.02
M4
x 0.7 x 0.5 3x0.5
x 0.7

.59
15
M3
M4 M4 x 0.5
x 0.7 x 0.7

dia.2.2 dia.2.2 dia.2.2 dia. 1 dia.1


dia. 2.2
(.09") (.09") (.09") (.04") (.04")
(.09")
( to be used only with XUD detectors )

XUFN12301 XUFN11311 XUFN10302 XUFN10312 XUFN35301 XUFN35311 XUFN0281

Ø0.08 Ø0.08
1 x dia. 1 1 x dia. 1 1 x dia. 1 1 x dia. 1 1 x dia. 0.5 1 x dia. 0.5 2.2 2.2
16 x dia. 2 x dia.
0.265 0.265 XUFZ910 ZUFZ921

Proximity (bifurcated)
Note: Emitter cable for XUFN05323, M6
XUFN04351, and XUFN02323
dia. 0.04 is marked with a white trace. Dia
dia. 0.08 dia. 0.04 On the amplifiers the emitter
dia. 0.08

32.5
dia. 0.08 1 1

1.3
2.2 2.2 is at the bottom. 0.04 (1)
2.2 Ø0.5
.70 13
18
M6 M4
Ø1.2
.11 .47

x 0.7 dia. 0.08


3 12

x 0.75
.59
15

2.2 5
M6 M 2.6
.70
18

x 0.75 x 0.45
.59
15
.11
3

dia.
.47
15 .59 12

Dia dia. 0.06


0.08
.11

0.04 (1) M3
3

2.2 M 6 1.5
15

38.1
x 0.5

970
3.5
90

x 0.75
.59
15

M4
.59

dia.
.47
3 12

dia. 0.08 x 0.7


M4 0.8
.31

2.2 M 2.6
11
8

x 0.7 x 0.45
M4
.47

x 0.7
90 0.11 12

M6 M6 Fiber tip diameter


x 0.75 x 0.75
.59

.59
15

15

Nuts M6 M4 M3
dia. 0.06
3.5 .13
90 3.5
3.5 0.2

Across flats 10 7 5
3.5

1.5
90 5

dia. 0.1 dia. 2.5 Note: Used only with XUD detectors
2.5
( to be used only with XUD detectors ) Ø0.08 Ø0.08
2.2 2.2
XUFN05321 XUFN15322 XUFN05323 XUFN01321 XUFN04331 XUDZ01 XUFN02323
XUFN05331 XUFN15332 XUFN01331
XUFS0520

2 x dia. 1 2 x dia. 1 1 x dia. 1 + 2 x dia. 2 x dia. 1 x dia. 0.5 + 1 x dia. 0.5 +


16 x dia. 0.5 0.265 8 x dia. 0.265 4 x dia. 0.25
0.265 Dual Dimensions inches
mm

168
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Dimensions of Accessories for XUF, XUA
Dimensions of Accessories for XUF, XUA

XUF
XUFZ210
M8x1 M4

Photoelectric Sensors
15 1000 20

XUFZ310
M10x1 M6

10
15 1000 20

XUFZ01 XUFZ03 XUFZ04 XUFZ05


0.10
2.75

0.10
2.75

0.10
2.75
0.22 (1) 0.10 0.22 0.10 0.22 0.10
5.5 2.75 5.5 2.75 5.5 (1) 2.75
ø0.2 (5)
ø0.18
4.5

0.37

0.37

0.37
ø0.14 ø0.14 ø0.14
9.5
0.6

0.6
9.5

9.5
15

15
0.11 (1)
3.5 3.5 3.5
0.23

3 0.4
0.6
0.23

0.23
15
6

6
10
0.3 0.47 0.3 0.47 0.3 0.47
7.5 12 7.5 12 7.5 12

XUFZ02 XUFZ13 XUFZ14 XUFZ15


0.10
2.75

0.10
2.75
0.22 0.10 0.22 0.10

0.10
2.75
ø0.11 (1) 0.22 0.10
2.8 5.5 2.75 5.5 2.75 5.5 2.75
ø0.2 (5)

0.6
15

9.5 0.6
9.5 0.6

15
15

(1)
ø0.14 ø0.14 ø0.14

0.37
0.37

0.37

0.25 (1)
9.5

3.5 3.5 3.5


0.23

6.5
0.23
0.23

0.36
6
6
6

9.2
0.3 0.47 0.3 0.47 0.3 0.47
7.5 12 7.5 12 7.5 12

XUA

XSAZ108 XSZB108 831608

Ø8 .53 .83 Ø8 1.50 .63


13.5 21 38 16
.49
.71 12.5
18 Ø3 screw
Ø3.8 panel drilling .30 .43
.37 7.5 11 .201 dia. thru
.12 .98
9.5 3 5
Ø3 .78 25
Ø3 panel drilling .375 dia. C
19.9 9.5 bore
= =
.28
.94 2 elongated holes 7
24 No. 8-32 UNC .31 dia.
4 x 8 (M4 screw) 2B Type 2 tap 8
.39 1.51
= =

1.06 .87
10 27 38.3
22 .260 dia. .63
6.6 16
.16
4

Dual Dimensions inches


mm

169
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Detectors Dimensions
XUV Detectors Dimensions

Thru-beam (pairs)

XUVN06240, 244 XUVN06520, 254 XUVN20210, 214 XUVN0243G, R XUVN0143G, R

.78 .47 .37


20 12 9.5
2 holes dia. 2.4 .11 .19
.13 5
Photoelectric Sensors

3
3.5

65.5
2.5
dia.

1.39
35.5
.21
5.5
.78
20

11
.78

.19
5

.21
5.5
20

1.77
45
3.0

.17
4.5
78
.13
.78
20
.86
22

3.5
.47

.11
.11

3
12 .17 .78
dia. 17 3
4.5 20 .43
2 holes dia. 4.6 11
2 holes Ø 3.4

.39
1.73

10
44 .94

.39
10
24

Reflex/Diffuse
XUVN0244 XUVN0245 XUVN05415 XUVN02428 XUVN01428
1.18
30 1.02
dia. 26
.78 2 holes Ø 2.4 .11
.78

.39
20

10
20 3
.19

18.5

.90
.72

23
5

.31
.78

.43
20

11

8
.78
20
.86
22

.23
6
dia. .66 .13 2 elongated
2 holes Ø 3.4
17 3.5 holes Ø 3.4 x 4.4
.65
16.5

.35
9
.35

1.41
9

36

Amplifiers
XUVF Examples of utilization and mounting positions of the XULZ41 mounting bracket
3.60
91.5 45
.59
15

2.69 1.77
68.5 45
1.43
36.5

3.09
78.5
2.50
63.5

XUVH/J

2 holes dia. 3.4


4.5 dia.
1.10
28

1.26
32
.78
20

.39 1.18
.55
10 30
2.36 Dual Dimensions inches
14.2 mm
60

170
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Substitution Guide
Substitution Guide

Old Design New Design Old Design New Design Old Design New Design
Design 18 XU1P18PP340WL5 XUB1APAWL5 + XUZC50 XU2P18PP340W XUB2APBWL2R + XUB2AKSWL2T

XU1B18NP340 XUB0ANSNL2 + XUZC50 XU1P18PP340WL5 XUB1APBWL5 + XUZC50 XU2P18PP340WD XUB2APAWM12R + XUB2AKAWM12T


XU1B18NP340D XUB0ANSNM12 + XUZC50 XU2B18NP340 XUB0ANSNL2 + XUB0AKSNL2T XU2P18PP340WD XUB2APBWM12R + XUB2AKAWM12T
XU1B18PP340 XUB 0APSNL2 + XUZC50 XU2B18NP340D XUB0ANSNM12 + XUB0AKSNM12T XU5B18NP340 XUB0ANSNL2
XU1B18PP340D XUB0APSNM12 + XUZC50 XU2B18PP340 XUB0APSNL2 + XUB0AKSNL2T XU5B18NP340D XUB0ANSNM12

Photoelectric Sensors
XU1N18NP340 XUB1BNANL2 + XUZC50 XU2B18PP340D XUB0APSNM12 + XUB0AKSNM12T XU5B18PP340 XUB0APSNL2
XU1N18NP340 XUB1BNBNL2 + XUZC50 XU2M18NP340 XUB0BNSNL2 + XUB0BKSNL2T XU5B18PP340D XUB0APSNM12
XU1N18NP340D XUB1BNANM12 + XUZC50 XU2M18NP340D XUB0BNSNM12 + XUB0BKSNM12T XU5B18PP340L5 XUB0APSNL5
XU1N18NP340D XUB1BNBNM12 + XUZC50 XU2M18NP340WD XUB0BNSWM12 + XUB0BKSWM12T XU5M18NP340 XUB0BNSNL2
XU1N18NP340L5 XUB1BNANL5 + XUZC50 XU2M18PP340 XUB0BPSNL2 + XUB0BKSNL2T XU5M18NP340D XUB0BNSNM12
XU1N18NP340L5 XUB1BNBNL5 + XUZC50 XU2M18PP340D XUB0BPSNM12 + XUB0BKSNM12T XU5M18NP340L5 XUB0BNSNL5
XU1N18NP340T10 XUB1BNANL2T10 + XUZC50 XU2M18PP340L10 XUB0BPSNL10 + XUB0BKSNL10T XU5M18NP340W XUB0BNSWL2
XU1N18NP340T10 XUB1BNBNL2T10 + XUZC50 XU2M18PP340L5 XUB0BPSNL5 + XUB0BKSNL5T XU5M18NP340WL5 XUB0BNSWL5
XU1N18NP340W XUB1BNAWL2 + XUZC50 XU2M18PP340W XUB0BPSWL2 + XUB0BKSWL2T XU5M18PP340 XUB0BPSNL2
XU1N18NP340W XUB1BNBWL2 + XUZC50 XU2M18PP340WD XUB0BPSWM12 + XUB0BKSWM12T XU5M18PP340D XUB0BPSNM12
XU1N18NP340WD XUB1BNAWM12 + XUZC50 XU2M18PP340WL5 XUB0BNSWL5 + XUB0BKSWL5T XU5M18PP340L5 XUB0BPSNL5
XU1N18NP340WD XUB1BNBWM12 + XUZC50 XU2N18NP340 XUB2BNANL2R + XUB2BKSNL2T XU5M18PP340W XUB0BPSWL2
XU1N18PP340 XUB1BPANL2 + XUZC50 XU2N18NP340 XUB2BNBNL2R + XUB2BKSNL2T XU5M18PP340WD XUB0BPSWM12
XU1N18PP340 XUB1BPBNL2 + XUZC50 XU2N18NP340D XUB2BNANM12R + XUB2BKSNM12T XU5M18PP340WL5 XUB0BPSWL5
XU1N18PP340D XUB1BPANM12 + XUZC50 XU2N18NP340D XUB2BNBNM12R + XUB2BKSNM12T XU5N18NP340 XUB4BNANL2
XU1N18PP340D XUB1BPBNM12 + XUZC50 XU2N18NP340WD XUB2BNAWM12R + XUB2BKAWM12T XU5N18NP340 XUB4BNBNL2
XU1N18PP340L5 XUB1BPANL5 + XUZC50 XU2N18NP340WD XUB2BNBWM12R + XUB2BKAWM12T XU5N18NP340D XUB4BNANM12
XU1N18PP340L5 XUB1BPBNL5 + XUZC50 XU2N18PP340 XUB2BPANL2R + XUB2BKSNL2T XU5N18NP340D XUB4BNBNM12
XU1N18PP340T10 XUB1BPANL2T10 + XUZC50 XU2N18PP340 XUB2BPBNL2R + XUB2BKSNL2T XU5N18NP340L5 XUB4BNANL5
XU1N18PP340T10 XUB1BPBNL2T10 + XUZC50 XU2N18PP340D XUB2BPANM12R + XUB2BKSNM12T XU5N18NP340L5 XUB4BNBNL5
XU1N18PP340W XUB1BPAWL2 + XUZC50 XU2N18PP340D XUB2BPBNM12R + XUB2BKSNM12T XU5N18NP340T10 XUB4BNANL2T10
XU1N18PP340W XUB1BPBWL2 + XUZC50 XU2N18PP340L5 XUB2BPANL5R + XUB2BKSNL5T XU5N18NP340T10 XUB4BNBNL2T10
XU1N18PP340WD XUB1BPAWM12 + XUZC50 XU2N18PP340L5 XUB2BPBNL5R + XUB2BKSNL5T XU5N18NP340W XUB4BNAWL2
XU1N18PP340WD XUB1BPBWM12 + XUZC50 XU2N18PP340W XUB2BPAWL2R + XUB2BKSWL2T XU5N18NP340W XUB4BNBWL2
XU1N18PP340WL5 XUB1BPAWL5 + XUZC50 XU2N18PP340W XUB2BPBWL2R + XUB2BKSWL2T XU5N18NP340WD XUB4BNAWM12
XU1N18PP340WL5 XUB1BPBWL5 + XUZC50 XU2N18PP340WD XUB2BPAWM12R + XUB2BKAWM12T XU5N18NP340WD XUB4BNBWM12
XU1P18NP340 XUB1ANANL2 + XUZC50 XU2N18PP340WD XUB2BPBWM12R + XUB2BKAWM12T XU5N18NP340WL5 XUB4BNAWL5
XU1P18NP340 XUB1ANBNL2 + XUZC50 XU2N18PP340WL5 XUB2BPAWL5R + XUB2BKSWL5T XU5N18NP340WL5 XUB4BNBWL5
XU1P18NP340D XUB1ANANM12 + XUZC50 XU2N18PP340WL5 XUB2BPBWL5R + XUB2BKSWL5T XU5N18PP340 XUB4BPANL2
XU1P18NP340D XUB1ANBNM12 + XUZC50 XU2P18NP340 XUB2ANANL2R + XUB2AKSNL2T XU5N18PP340 XUB4BPBNL2
XU1P18NP340L5 XUB1ANANL5 + XUZC50 XU2P18NP340 XUB2ANBNL2R + XUB2AKSNL2T XU5N18PP340D XUB4BPANM12
XU1P18NP340L5 XUB1ANBNL5 + XUZC50 XU2P18NP340D XUB2ANANM12R + XUB2AKSNM12T XU5N18PP340D XUB4BPBNM12
XU1P18NP340W XUB1ANAWL2 + XUZC50 XU2P18NP340D XUB2ANBNM12R + XUB2AKSNM12T XU5N18PP340L5 XUB4BPANL5
XU1P18NP340W XUB 1ANBWL2 + XUZ C50 XU2P18NP340W XUB2ANAWL2R + XUB2AKSWL2T XU5N18PP340L5 XUB4BPBNL5
XU1P18NP340WD XUB1ANAWM12 + XUZC50 XU2P18NP340W XUB2ANBWL2R + XUB2AKSWL2T XU5N18PP340T10 XUB4BPANL2T10
XU1P18NP340WD XUB1ANBWM12 + XUZC50 XU2P18NP340WD XUB2ANAWM12R + XUB2AKAWM12T XU5N18PP340T10 XUB4BPBNL2T10
XU1P18PP340 XUB1APANL2 + XUZC50 XU2P18NP340WD XUB2ANBWM12R + XUB2AKAWM12T XU5N18PP340W XUB4BPAWL2
XU1P18PP340 XUB1APBNL2 + XUZC50 XU2P18PP340 XUB2APANL2R + XUB2AKSNL2T XU5N18PP340W XUB4BPBWL2
XU1P18PP340D XUB1APANM12 + XUZC50 XU2P18PP340 XUB2APBNL2R + XUB2AKSNL2T XU5N18PP340WD XUB4BPAWM12
XU1P18PP340D XUB1APBNM12 + XUZC50 XU2P18PP340D XUB2APANM12R + XUB2AKSNM12T XU5N18PP340WD XUB4BPBWM12
XU1P18PP340L5 XUB1APANL5 + XUZC50 XU2P18PP340D XUB2APBNM12R + XUB2AKSNM12T XU5N18PP340WL5 XUB4BPAWL5
XU1P18PP340L5 XUB1APBNL5 + XUZC50 XU2P18PP340L10 XUB2APANL10R + XUB2AKSNL10T XU5N18PP340WL5 XUB4BPBWL5
XU1P18PP340W XUB1APAWL2 + XUZC50 XU2P18PP340L10 XUB2APBNL10R + XUB2AKSNL10T XU5P18NP340 XUB4ANANL2
XU1P18PP340W XUB1APBWL2 + XUZC50 XU2P18PP340L5 XUB2APANL5R + XUB2AKSNL5T XU5P18NP340 XUB4ANBNL2
XU1P18PP340WD XUB1APAWM12 + XUZC50 XU2P18PP340L5 XUB2APBNL5R + XUB2AKSNL5T XU5P18NP340D XUB4ANANM12
XU1P18PP340WD XUB1APBWM12 + XUZC50 XU2P18PP340W XUB2APAWL2R + XUB2AKSWL2T XU5P18NP340D XUB4ANBNM12

171
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Substitution Guide
Substitution Guide

Old Design New Design Old Design New Design Old Design New Design
Design 18 XU9N18NP340 XUB9BNANL2 + XUZC50 XUDJ003937S XUDA2NSMM8

XU5P18NP340L5 XUB4ANANL5 XU9N18NP340 XUB9BNBNL2 + XUZC50 Design Compact


XU5P18NP340L5 XUB4ANBNL5 XU9N18NP340D XUB9BNANM12 + XUZC50 XUEF010315 XUX0ARCTT16 + XUZX2000
XU5P18NP340W XUB4ANAWL2 XU9N18NP340D XUB9BNBNM12 + XUZC50 XUEF010315H7 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU5P18NP340W XUB4ANBWL2 XU9N18NP340L5 XUB9BNANL5 + XUZC50 XUEF080319 XUX0ARCTT16 + XUZX2000
Photoelectric Sensors

XU5P18NP340WD XUB4ANAWM12 XU9N18NP340L5 XUB9BNBNL5 + XUZC50 XUEF080319H4 XUX0ARCTT16 + XUZX2000 + XUZX2001


XU5P18NP340WD XUB4ANBWM12 XU9N18NP340W XUB9BNAWL2 + XUZC50 XUEF10031 XUX0ARCTT16 + XUZX2000
XU5P18PP340 XUB4APANL2 XU9N18NP340W XUB9BNBWL2 + XUZC50 XUEF10031H7 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU5P18PP340 XUB4APBNL2 XU9N18NP340WD XUB9BNAWM12 + XUZC50 XUEF300314 XUX0ARCTT16 + XUZX2000
XU5P18PP340D XUB4APANM12 XU9N18NP340WD XUB9BNBWM12 + XUZC50 XUEF300314H7 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU5P18PP340D XUB4APBNM12 XU9N18PP340 XUB9BPANL2 + XUZC50 XUEH017535 XUX0AKSAT16 + XUZX2000
XU5P18PP340L10 XUB4APANL10 XU9N18PP340 XUB9BPBNL2 + XUZC50 XUEH017535H7 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU5P18PP340L10 XUB4APBNL10 XU9N18PP340D XUB9BPANM12 + XUZC50 XUEH10753 XUX0AKSAT16 + XUZX2000
XU5P18PP340L5 XUB4APANL5 XU9N18PP340D XUB9BPBNM12 + XUZC50 XUEH10753H7 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU5P18PP340L5 XUB4APBNL5 XU9N18PP340L5 XUB9BPANL5 + XUZC50 XUEH3000 XUX0AKSAT16T + XUZX2000
XU5P18PP340W XUB4APAWL2 XU9N18PP340L5 XUB9BPBNL5 + XUZC50 XUEH3000H7 XUX0AKSAT16T + XUZX2000 + XUZX2001
XU5P18PP340W XUB4APBWL2 XU9N18PP340W XUB9BPAWL2 + XUZC50 XUEH307534 XUX0AKSAT16 + XUZX2000
XU5P18PP340WD XUB4APAWM12 XU9N18PP340W XUB9BPBWL2 + XUZC50 XUEH307534H7 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU5P18PP340WD XUB4APBWM12 XU9N18PP340WD XUB9BPAWM12 + XUZC50 XUEH753538 XUX0AKSAT16 + XUZX2000
XU5P18PP340WL5 XUB4APAWL5 XU9N18PP340WD XUB9BPBWM12 + XUZC50 XUEH753538H4 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU5P18PP340WL5 XUB4APBWL5 XU9N18PP340WL5 XUB9BPAWL5 + XUZC50 XUET010315 XUX0ARCTT16 + XUZX2000
XU8B18NP340 XUB0ANSNL2 XU9N18PP340WL5 XUB9BPBWL5 + XUZC50 XUET010315H7 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU8B18NP340D XUB0ANSNM12 XU9P18NP340 XUB9ANANL2 + XUZC50 XUET080319 XUX0ARCTT16 + XUZX2000
XU8B18PP340 XUB0APSNL2 XU9P18NP340 XUB9ANBNL2 + XUZC50 XUET080319H4 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU8B18PP340D XUB0APSNM12 XU9P18NP340D XUB9ANANM12 + XUZC50 XUET10031 XUX0ARCTT16 + XUZX2000
XU8B18PP340L10 XUB0APSNL10 XU9P18NP340D XUB9ANBNM12 + XUZC50 XUET10031H7 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU8M18NP340 XUB0BNSNL2 XU9P18NP340L5 XUB9ANANL5 + XUZC50 XUET300314 XUX0ARCTT16 + XUZX2000
XU8M18NP340D XUB0BNSNM12 XU9P18NP340L5 XUB9ANBNL5 + XUZC50 XUET300314H7 XUX0ARCTT16 + XUZX2000 + XUZX2001
XU8M18NP340L5 XUB0BNSNL5 XU9P18NP340W XUB9ANAWL2 + XUZC50 XUJK06353 XUX0AKSAT16 + XUZX2000
XU8M18NP340W XUB0BNSWL2 XU9P18NP340W XUB9ANBWL2 + XUZC50 XUJK063539 XUX0AKSAT16 + XUZX2000
XU8M18NP340WD XUB0BNSWM12 XU9P18NP340WD XUB9ANAWM12 + XUZC50 XUJK063539D1 XUX0AKSAM12 + XUZX2000
XU8M18PP340 XUB0BPSNL2 XU9P18NP340WD XUB9ANBWM12 + XUZC50 XUJK063539D2 XUX0AKSAM12 + XUZX2000
XU8M18PP340D XUB0BPSNM12 XU9P18PP340 XUB9APANL2 + XUZC50 XUJK063539H7 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU8M18PP340L5 XUB0BPSNL5 XU9P18PP340 XUB9APBNL2 + XUZC50 XUJK063539P9 XUX0AKSAT16 + XUZX2000
XU8M18PP340W XUB0BPSWL2 XU9P18PP340D XUB9APANM12 + XUZC50 XUJK06353D1 XUX0AKSAM12 + XUZX2000
XU8M18PP340WD XUB0BPSWM12 XU9P18PP340D XUB9APBNM12 + XUZC50 XUJK06353D2 XUX0AKSAM12 + XUZX2000
XU9B18NP340 XUB0ANSNL2 + XUZC50 XU9P18PP340W XUB9APAWL2 + XUZC50 XUJK06353H7 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU9B18NP340D XUB0ANSNM12 + XUZC50 XU9P18PP340W XUB9APBWL2 + XUZC50 XUJK06353P9 XUX0AKSAT16 + XUZX2000
XU9B18PP340 XUB0APSNL2 + XUZC50 XU9P18PP340WD XUB9APAWM12 + XUZC50 XUJK103534 XUX0AKSAT16 + XUZX2000
XU9B18PP340D XUB0APSNM12 + XUZC50 XU9P18PP340WD XUB9APBWM12 + XUZC50 XUJK103534D1 XUX0AKSAM12 + XUZX2000
XU9B18PP340L5 XUB0APSNL5 + XUZC50 XU9P18PP340WL5 XUB9APANL5 + XUZC50 XUJK103534D2 XUX0AKSAM12 + XUZX2000
XU9M18NP340 XUB0BNSNL2 + XUZC50 XU9P18PP340WL5 XUB9APBNL5 + XUZC50 XUJK103534P9 XUX0AKSAT16 + XUZX2000

XU9M18NP340D XUB0BNSNM12 + XUZC50 Design Amplifier XUJK123538 XUX0AKSAT16 + XUZX2000

XU9M18NP340L5 XUB0BNSNL5 + XUZC50 XUDH003537 XUDA1PSML2 XUJK123538D1 XUX0AKSAM12 + XUZX2000


XU9M18NP340W XUB0BNSWL2 + XUZC50 XUDH003537S XUDA1PSMM8 XUJK123538D2 XUX0AKSAM12 + XUZX2000
XU9M18PP340 XUB0BPSNL2 + XUZC50 XUDH003537T10 XUDA1PSML2T10 XUJK123538P9 XUX0AKSAT16 + XUZX2000
XU9M18PP340D XUB0BPSNM12 + XUZC50 XUDH003937 XUDA2PSML2 XUJK703538 XUX0AKSAT16 + XUZX2000
XU9M18PP340L5 XUB0BPSNL5 + XUZC50 XUDH003937S XUDA2PSMM8 XUJK703538D1 XUX0AKSAM12 + XUZX2000
XU9M18PP340W XUB0BPSWL2 + XUZC50 XUDJ003537 XUDA1NSML2 XUJK703538D2 XUX0AKSAM12 + XUZX2000
XU9M18PP340WD XUB0BPSWM12 + XUZC50 XUDJ003537S XUDA1NSMM8 XUJK703538H7 XUX0AKSAT16 + XUZX2000 + XUZX2001
XU9M18PP340WL5 XUB0BPSWL5 + XUZC50 XUDJ003937 XUDA2NSML2 XUJK703538P9 XUX0AKSAT16 + XUZX2000

172
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Substitution Guide
Substitution Guide

Old Design New Design Old Design New Design Old Design New Design
Design Compact XUJT060319P9 XUX0ARCTT16 + XUZX2000 XULH043539DH7 XUK9APANM12 + XUZK2003
XUJLM0811 XUX1ARCNT16 + XUZX2000 XUJT06031D1 XUX0ARCTT16 + XUZX2000 XULH043539DH7 XUK9APBNM12 + XUZK2003
XUJLM0811H7 XUX1ARCNT16 + XUZX2000 + XUZX2001 XUJT06031D2 XUX0ARCTT16 + XUZX2000 XULH043539H7 XUK9APANL2 + XUZK2003
XUJLM0811P9 XUX1ARCNT16 + XUZX2000 XUJT06031P9 XUX0ARCTT16 + XUZX2000 XULH043539H7 XUK9APBNL2 + XUZK2003
XUJLM0811T10 XUX1ARCNT16T10 + XUZX2000 XUJT100314 XUX0ARCTT16 + XUZX2000 XULH043539L05 XUK9APANL5 + XUZK2003

Photoelectric Sensors
XUJLM1503 XUX0ARCTT16T + XUZX2000 XUJT100314D1 XUX0ARCTT16 + XUZX2000 XULH043539L05 XUK9APBNL5 + XUZK2003
XUJLM1503H7 XUX0ARCTT16T + XUZX2000 + XUZX2001 XUJT100314D2 XUX0ARCTT16 + XUZX2000 XULH043539L10 XUK9APANL10 + XUZK2003
XUJLM1503P9 XUX0ARCTT16T + XUZX2000 XUJT100314H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH043539L10 XUK9APBNL10 + XUZK2003
XUJLM1514 XUX2ARCNT16R + XUZX2000 XUJT100314P9 XUX0ARCTT16 + XUZX2000 XUJLM0619 XUK9ARCNL2 + XUZX2000
XUJLM1514H7 XUX2ARCNT16R + XUZX2000 + XUZ X2001 XUJT120318 XUX0ARCTT16 + XUZX2000 XUJLM0619H7 XUK9ARCNL2 + XUZX2000
XUJLM1514P9 XUX2ARCNT16R + XUZ X2000 XUJT120318D1 XUX0ARCTT16 + XUZX2000 XUJLM0619P9 XUK9ARCNL2 + XUZX2000
XUJM06031 XUX0ARCTT16 + XUZX2000 XUJT120318D2 XUX0ARCTT16 + XUZX2000 XULH06353 XUK1APANL2 + XUZK2003
XUJM060319 XUX0ARCTT16 + XUZX2000 XUJT120318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH06353 XUK1APBNL2 + XUZK2003
XUJM060319D1 XUX0ARCTT16 + XUZX2000 XUJT120318P9 XUX0ARCTT16 + XUZX2000 XULH06353D XUK1APANM12 + XUZK2003
XUJM060319D2 XUX0ARCTT16 + XUZX2000 XUJT700318 XUX0ARCTT16 + XUZX2000 XULH06353D XUK1APBNM12 + XUZK2003
XUJM060319H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUJT700318D1 XUX0ARCTT16 + XUZX2000 XULH06353H7 XUK1APANL2 + XUZK2003
XUJM060319P9 XUX0ARCTT16 + XUZX2000 XUJT700318D2 XUX0ARCTT16 + XUZX2000 XULH06353H7 XUK1APBNL2 + XUZK2003
XUJM06031D1 XUX0ARCTT16 + XUZX2000 XUJT700318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH06353L05 XUK1APANL5 + XUZK2003
XUJM06031D2 XUX0ARCTT16 + XUZX2000 XUJT700318P9 XUX0ARCTT16 + XUZX2000 XULH06353L05 XUK1APBNL5 + XUZK2003

XUJM06031H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 Design Compact 50 x 50 XULH06353L10 XUK1APANL10 + XUZK2003

XUJM06031P9 XUX0ARCTT16 + XUZX2000 XUK1ARCTL10 XUK0ARCTL10 + XUZK2003 + XUZA50 XULH06353L10 XUK1APBNL10 + XUZK2003
XUJM1000 XUX0AKSAT16T + XUZX2000 XUK1ARCTL2 XUK0ARCTL2 + XUZK2003 + XUZA50 XULH083534 XUK2APANL2R + XUZK2003
XUJM1000 XUX0ARCTT16T + XUZX2000 XUK2AKSAL10 XUK0AKSAL10 + XUZK2003 + XUK0AKSAL10T + XUZK2003 XULH083534 XUK2APBNL2R + XUZK2003
XUJM1000D1 XUX0AKSAM12T + XUZX2000 XUK2AKSAL10R XUK0AKSAL10 + XUZK2003 XULH083534D XUK2APANM12R + XUZK2003
XUJM1000D1 XUX0ARCTT16T + XUZX2000 XUK2AKSAL10T XUK0AKSAL10T + XUZK2003 XULH083534D XUK2APBNM12R + XUZK2003
XUJM1000D2 XUX0AKSAM12T + XUZX2000 XUK2AKSAL2 XUK0AKSAL2 + XUZK2003 + XUK0AKSAL2T + XUZK2003 XULH083534DH7 XUK2APANM12R + XUZK2003
XUJM1000D2 XUX0ARCTT16T + XUZX2000 XUK2AKSAL2R XUK0AKSAL2 + XUZK2003 XULH083534DH7 XUK 2APBNM12R + XUZK2003
XUJM1000H7 XUX0AKSAT16T + XUZX2000 + XUZX2001 XUK2AKSAL2T XUK0AKSAL2T + XUZK2003 XULH083534L05 XUK2APANL5R + XUZK2003
XUJM1000H7 XUX0ARCTT16T + XUZX2000 + XUZX2001 XUK2AKSAM12 XUK0AKSAM12 + XUZK2003 + XUK0AKSAM12T + XUZK2003 XULH083534L05 XUK2APBNL5R + XUZK2003
XUJM1000P9 XUX0AKSAT16T + XUZX2000 XUK2AKSAM12R XUK0AKSAM12 + XUZK2003 XULH083534L10 XUK2APANL10R + XUZK2003
XUJM1000P9 XUX0ARCTT16T + XUZX2000 XUK2AKSAM12T XUK0AKSAM12T + XUZK2003 XULH083534L10 XUK2APBNL10R + XUZK2003
XUJM100314 XUX0ARCTT16 + XUZX2000 XUK2ARCTL10 XUK0ARCTL10 + XUZK2003 + XUK2ARCTL10T + XUZK2003 XULH153538 XUK0AKSAL2 + XUZK2003
XUJM100314D1 XUX0ARCTT16 + XUZX2000 XUK2ARCTL10R XUK0ARCTL10 + XUZK2003 XULH153538D XUK0AKSAM12 + XUZK2003
XUJM100314D2 XUX0ARCTT16 + XUZX2000 XUK2ARCTL10T XUK2ARCTL10T + XUZK2003 XULH153538H7 XUK0AKSAL2 + XUZK2003
XUJM100314H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUK2ARCTL2 XUK0ARCTL2 + XUZK2003 + XUK2ARCTL2T + XUZK2003 XULH153538L05 XUK0AKSAL5 + XUZK2003
XUJM100314P9 XUX0ARCTT16 + XUZX2000 XUK2ARCTL2R XUK0ARCTL2 + XUZK2003 XULH303538 XUK0AKSAL2 + XUZK2003
XUJM120318 XUX0ARCTT16 + XUZX2000 XUK2ARCTL2T XUK2ARCTL2T + XUZK2003 XULH303538D XUK0AKSAM12 + XUZK2003
XUJM120318D1 XUX0ARCTT16 + XUZX2000 XUK5AKSAL10 XUK0AKSAL10 + XUZK2003 XULH303538DH7 XUK0AKSAM12 + XUZK2003
XUJM120318D2 XUX0ARCTT16 + XUZX2000 XUK5AKSAL2 XUK0AKSAL2 + XUZK2003 XULH303538L05 XUK0AKSAL5 + XUZK2003
XUJM120318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUK5AKSAM12 XUK0AKSAM12 + XUZK2003 XULH303538L10 XUK0AKSAL10 + XUZK2003
XUJM120318P9 XUX0ARCTT16 + XUZX2000 XUK5ARCTL10 XUK0ARCTL10 + XUZK2003 XULH703535 XUK5APANL2 + XUZK2003
XUJM700318 XUX0ARCTT16 + XUZX2000 XUK5ARCTL2 XUK0ARCTL2 + XUZK2003 XULH703535 XUK5APBNL2 + XUZK2003
XUJM700318D1 XUX0ARCTT16 + XUZX2000 XUK9AKSAL10 XUK0AKSAL10 + XUZK2003 + XUZA50 XULH703535D XUK5APANM12 + XUZK2003
XUJM700318D2 XUX0ARCTT16 + XUZX2000 XUK9AKSAL2 XUK0AKSAL2 + XUZK2003 + XUZA50 XULH703535D XUK5APBNM12 + XUZK2003
XUJM700318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUK9AKSAM12 XUK0AKSAM12 + XUZK2003 + XUZA50 XULH703535H7 XUK5APANL2 + XUZK2003
XUJM700318P9 XUX0ARCTT16 + XUZX2000 XUK9ARCTL10 XUK0ARCTL10 + XUZK2003 + XUZA50 XULH703535H7 XUK5APBNL2 + XUZK2003
XUJT06031 XUX0ARCTT16 + XUZX2000 XUK9ARCTL2 XUK0ARCTL2 + XUZK2003 + XUZA50 XULH703535L05 XUK5APANL5 + XUZK2003
XUJT060319 XUX0ARCTT16 + XUZX2000 XULH043539 XUK9APANL2 + XUZK2003 XULH703535L05 XUK5APBNL5 + XUZK2003
XUJT060319D1 XUX0ARCTT16 + XUZX2000 XULH043539 XUK9APBNL2 + XUZK2003 XULH703535L10 XUK5APANL10 + XUZK2003
XUJT060319D2 XUX0ARCTT16 + XUZX2000 XULH043539D XUK9APANM12 + XUZK2003 XULH703535L10 XUK5APBNL10 + XUZK2003
XUJT060319H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH043539D XUK9APBNM12 + XUZK2003 XULJ043539 XUK9ANANL2 + XUZK2003

173
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Substitution Guide

Old Design New Design Old Design New Design Old Design New Design
Design Compact 50 x 50 XUMH023539L10 XUM0APSAL10 + XUZM2003 XUMLJ0451S XUM1ANBM8 + XUZM2003
XULJ043539 XUK9ANBNL2 + XUZK2003 XUMH03353 XUM0APSAL2 + XUZM2003 XUMLJ0854 XUM2ANANL2R + XUZM2003
XULJ043539D XUK9ANANM12 + XUZK2003 XUMH03353L10 XUM0APSAL10 + XUZM2003 XUMLJ0854 XUM2ANBNL2R + XUZM2003
XULJ043539D XUK9ANBNM12 + XUZK2003 XUMH07301 XUM2AKSNL2T + XUZM2003 XUMLJ0854S XUM2ANANM8R + XUZM2003
XULJ06353 XUK1ANANL2 + XUZK2003 XUMH07301L10 XUM2AKSNL10T + XUZM2003 XUMLJ0854S XUM2ANBNM8R + XUZM2003
Photoelectric Sensors

XULJ06353 XUK1ANBNL2 + XUZK2003 XUMH073534 XUM0APSAL2 + XUZM2003 XUMLJ1055 XUM6ANANL2 + XUZM2003


XULJ06353D XUK1ANANM12 + XUZK2003 XUMH073534L10 XUM0APSAL10 + XUZM2003 XUMLJ1055 XUM6ANBNL2 + XUZM2003
XULJ06353D XUK1ANBNM12 + XUZK2003 XUMH103535 XUM0APSAL2 + XUZM2003 XUMLJ1055S XUM6ANANM8 + XUZM2003
XULJ06353L10 XUK1ANANL10 + XUZK2003 XUMH15353R XUM0APSAL2 + XUZM2003 XUMLJ1055S XUM6ANBNM8 + XUZM2003
XULJ06353L10 XUK1ANBNL10 + XUZK2003 XUMH703535 XUM0APSAL2 + XUZM2003 XUMLJ4055 XUM5ANANL2 + XUZM2003
XULJ083534 XUK2ANANL2R + XUZK2003 XUMJ023539 XUM0ANSAL2 + XUZM2003 XUMLJ4055 XUM5ANBNL2 + XUZM2003
XULJ083534D XUK2ANANM12R + XUZK2003 XUMJ03353 XUM0ANSAL2 + XUZM2003 XUMLJ4055S XUM5ANANM8 + XUZM2003
XULJ153538 XUK0AKSAL2 + XUZK2003 XUMJ073534 XUM0ANSAL2 + XUZM2003 XUMLJ4055S XUM5ANBNM8 + XUZM2003
XULJ153538D XUK0AKSAM12 + XUZK2003 XUMJ103535 XUM0ANSAL2 + XUZM2003
XULJ153538H7 XUK0AKSAL2 + XUZK2003 XUMJ15353R XUM0ANSAL2 + XUZM2003
XULJ153538L05 XUK0AKSAL5 + XUZK2003 XUMJ703535 XUM0ANSAL2 + XUZM2003
XULJ303538 XUK0AKSAL2 + XUZK2003 XUMLH0259 XUM9APANL2 + XUZM2003
XULJ303538D XUK0AKSAM12 + XUZK2003 XUMLH0259 XUM9APBNL2 + XUZM2003
XULJ303538L05 XUK0AKSAL5 + XUZK2003 XUMLH0259S XUM9APANM8 + XUZM2003
XULJ703535 XUK5ANANL2 + XUZK2003 XUMLH0259S XUM9APBNM8 + XUZM2003
XULJ703535 XUK5ANBNL2 + XUZK2003 XUMLH0451 XUM1APANL2 + XUZM2003
XULJ703535D XUK5ANANM12 + XUZK2003 XUMLH0451 XUM1APBNL2 + XUZM2003
XULJ703535D XUK5ANBNM12 + XUZK2003 XUMLH0451L10 XUM1APANL10 + XUZM2003
XULK0830 XUK2AKSNL2T + XUZK2003 XUMLH0451L10 XUM1APBNL10 + XUZM2003
XULK0830D XUK2AKSNM12T + XUZK2003 XUMLH0451S XUM1APANM8 + XUZM2003
XULK0830L05 XUK2AKSNL5T + XUZK2003 XUMLH0451S XUM1APBNM8 + XUZM2003
XULK0830L10 XUK2AKSNL10T + XUZK2003 XUMLH0451T10 XUM1APANL2T10 + XUZM2003
XULM040319 XUK9ARCNL2 + XUZK2003 XUMLH0451T10 XUM1APBNL2T10 + XUZM2003
XULM040319H7 XUK9ARCNL2 + XUZK2003 XUMLH0803 XUM2AKSNL2T + XUZM2003
XULM040319L05 XUK9ARCNL5 + XUZK2003 XUMLH0803S XUM2AKSNM8T + XUZM2003
XULM040319L10 XUK9ARCNL10 + XUZK2003 XUMLH0854 XUM2APANL2R + XUZM2003
XULM0600 XUK2ARCNL2T + XUZK2003 XUMLH0854 XUM2APBNL2R + XUZM2003
XULM0600H7 XUK2ARCNL2T + XUZK2003 XUMLH0854S XUM2APANM8R + XUZM2003
XULM0600L05 XUK2ARCNL5T + XUZK2003 XUMLH0854S XUM2APBNM8R + XUZM2003
XULM0600L10 XUK2ARCNL10T + XUZK2003 XUMLH1055 XUM6APANL2 + XUZM2003
XULM06031 XUK1ARCNL2 + XUZK2003 XUMLH1055 XUM6APBNL2 + XUZM2003
XULM06031H7 XUK1ARCNL2 + XUZK2003 XUMLH1055S XUM6APANM8 + XUZM2003
XULM06031H7L10 XUK1ARCNL10 + XUZK2003 XUMLH1055S XUM6APBNM8 + XUZM2003
XULM06031L05 XUK1ARCNL5 + XUZK2003 XUMLH4055 XUM5APANL2 + XUZM2003
XULM06031L10 XUK1ARCNL10 + XUZK2003 XUMLH4055 XUM5APBNL2 + XUZM2003
XULM080314 XUK2ARCNL2R + XUZK2003 XUMLH4055S XUM5APANM8 + XUZM2003
XULM080314H7 XUK2ARCNL2R + XUZK2003 XUMLH4055S XUM5APBNM8 + XUZM2003
XULM080314L05 XUK2ARCNL5R + XUZK2003 XUMLH4055T10 XUM5APANL2T10 + XUZM2003
XULM080314L10 XUK2ARCNL10R + XUZK2003 XUMLH4055T10 XUM5APBNL2T10 + XUZM2003
XULM300318 XUK0ARCTL2 + XUZK2003 XUMLJ0259 XUM9ANANL2 + XUZM2003
XULM300318H7 XUK0ARCTL2 + XUZK2003 XUMLJ0259 XUM9ANBNL2 + XUZM2003
XULM300318H7L10 XUK0ARCTL10 + XUZK2003 XUMLJ0259S XUM9ANANM8 + XUZM2003
XULM300318L05 XUK0ARCTL5 + XUZK2003 XUMLJ0259S XUM9ANBNM8 + XUZM2003
XULM300318L10 XUK0ARCTL10 + XUZK2003 XUMLJ0451 XUM1ANANL2 + XUZM2003

Design Miniature XUMLJ0451 XUM1ANBNL2 + XUZM2003

XUMH023539 XUM0APSAL2 + XUZM2003 XUMLJ0451S XUM1ANANM8 + XUZM2003

174
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
General
General

Principles of A photo-electric sensor basically comprises a light beam emitter (light emitting
Composition of diode) and a light sensitive receiver (photo-transistor).
optical detection a photo-electric A light emitting diode is an electronic semi-conductor component which emits
sensor light when an electrical current flows through it. This light can be visible or
invisible, depending on the transmission wavelength.
Detection occurs when an object enters the transmitted light beam and, in so
doing, affects the intensity of the light at the receiver. As the light intensity at

Photoelectric Sensors
the receiver decreases, a point is reached whereby the output of the sensor
changes state.

1 3 4

1 Light beam emitter


2 Light beam receiver
3 Processing stage
4 Output stage

Depending on the model, the transmission beam is either infra-red, visible red
Light spectrum or visible green.
Visible red light emitting diodes (LEDs) and photo-transistors are used for
plastic fiber optic and polarized retroreflective system sensors.

10
1 nm 400 nm 750 nm 3 µm

100 200 300 500 600 700 800 900 1000 1100

The advantage of LEDs is their very fast response. To render the


Modulation system insensitive to ambient light, the current flowing through the LED is
modulated to produce a pulsed light transmission.
Only the pulsed signal will be used by the photo-transistor and processed to
control the load.

175
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Detection Systems
Detection Systems

Thru-beam The thru-beam system comprises 2 components:


an emitter and a receiver.
system • long sensing distance - up to 203 ft (62m)
• precise and reliable detection
• good resistance in polluted environments (dust,
stray light beams, etc.)
But:
Photoelectric Sensors

- the object to be detected must be opaque


- it requires 2 components, that must be mounted
facing each other (emitter and receiver)

Retroreflective The retroreflective system comprises an emitter/receiver


unit and a reflector for returning the transmitted light beam
system back to the receiver.
• medium sensing distance
• precise detection
• simple installation and setting-up (only one
component to be wired)
• detection of opaque objects (general retroreflect-
ive system) or non reflective transparent objects
(retroreflective system specifically for
transparent materials)
But: only recommended for use in clean
environments.

Polarized The polarized retroreflective system is an extension of the


retroreflective system and incorporates light beam
retroreflective polarization filters. These filters enable reflective objects to
system be detected.
Their characteristics are identical to those of the
retroreflective system, but include the following features:
- reliable detection of all types of reflective
objects, due to the polarization filters
- visible light beam transmission (red), which
assists alignment of the system

Proximity The proximity diffuse system simply comprises one emitter/


receiver unit. It is the object itself which
diffuse system reflects the transmitted light beam back to the receiver.
• short sensing distance which is dependent on
the color of the object (reflection coefficient)
• simple installation and setting-up (only one
component to be mounted and wired)
• detection of any type of object (opaque,
reflective or transparent)
But: only recommended for use in clean
environments.

Proximity The proximity diffuse system with background suppression


is an extension of the proximity diffuse system and
diffuse system incorporates features which make it insensitive to
with background objects.
Their characteristics are identical to those of the proximity
background diffuse system, but include the following features:
- sensing distance not related to color of object
suppression - insensitive to background objects, even if they
are more reflective than the object to be
detected

176
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Specific Aspects of the Various Detection Systems
Specific Aspects of the Various Detection Systems

Thru-beam The thru-beam system requires precise alignment of the emitter and receiver.
Alignment of emitter
system and receiver
For long sensing distance thru-beam systems it is recommended that the
mechanical alignment tool be used.

Photoelectric Sensors
Retroreflective The reflector comprises a considerable number of corner cube cavities which
Function of ensure total reflection of all light rays back along the same path.
system the reflector Types of reflector:
- circular,
- rectangular,
- reflective tape.
The reflector orientation angle (α) must be between 10 and 20°
(see sensing distance correction coefficient below).

40

α 30
20
10
0
0 80 % 100 %

Angle of incidence α Correction coefficient

Effect of reflector size on sensing distance of sensor.


Choice of
XUZC16
reflector XUZC21
XUZC31
XUZC39
XUZC80
XUZC100
XUZC24
XUZC50
XUZB01/B05 c
XUZB11/B15 c
0 10 % 25 % 50 % 75 % 100 % 125 % 150 %

XUE, XUJ, XUL, XUM, ZUC


XUE, XUJ, XUL, XUM polarized retroreflective, ZUC
XUB, XUP, XU••18
c For an equivalent surface area to that of the XUZC80.

The reflector must be smaller than the object to be detected.

177
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Specific Aspects of the Various Detection Systems
Specific Aspects of the Various Detection Systems

Retroreflective The positioning of the reflector must be very precise, in order to reflect the
Positioning transmitted beam back to the receiver.
system (cont.) the reflector
Photoelectric Sensors

Incorrect orientation
Incorrect centering
Correct position

In order to avoid inadvertent operation due to stray reflections, avoid mounting


the sensor-reflector optical axis at right-angles to the object to be detected, or
any other reflective objects.

When using a reflector with small corner cubes (for example XUZC80) for short
Using reflectors for sensing distances (D < 10% Sn), almost all of the beam is reflected back to the
short sensing emitter and the sensor fails to
distances operate correctly. The use of a reflector with large corner cubes (for example
XUZC24 and XUZC50) ensures that the light beam will be
reflected back towards the receiver.

D D

D < 10% Sn

Polarized In the polarized retroreflective system, the transmitted light beam is


Detection of highly filtered so that only the rays on a vertical plane are passed through. The corner
retroreflective reflective objects cube reflector depolarizes the beam and reflects it back to the receiver, which is
system designed to accept light rays on a horizontal plane only.
Applications: A reflective object sends back the light rays in the same plane on
which they were received (vertical plane). The beam is blocked by the receiver
filter, since only rays on a horizontal plane are accepted.

1
2

1
3

4
1Non polarized
2Vertically polarized
3Horizontally polarized
4The reflector depolarizes the light beam

178
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Specific Aspects of the Various Detection Systems
Specific Aspects of the Various Detection Systems

Proximity diffuse The sensing distance of a proximity diffuse system sensor is


Influence of the influenced by the object material (reflection coefficient, color, etc.).
system object material
to be detected Usable sensing distance
Sn
1,2 Sn
Sn

Photoelectric Sensors
0,5 Sn
Object reflection
coefficient
0,1 Sn
10 % 50 % 100 % 140 %
White paper
Brown cardboard
Planed wood
Wooden pallets
Aluminum
Plastic bottles
Rubber

The curve above indicates the usable sensing distance (Sn) correction factor
related to the reflection coefficient of the object.
Note: If the application requires that different object materials be
detected at the same distance, the choice of sensor and adjustment of the
sensitivity is based on the object which has the lowest reflection coefficient.

In the event of background objects being present which are more


Influence of reflective than the object to be detected, the proximity diffuse system is not
background suitable. To avoid the background being detected, it is advisable to use a
objects proximity diffuse system with background suppression.

ON ON

Proximity diffuse This system enables detection of an object at a given distance


Principle irrespective of its color (reflection coefficient), while ignoring any background
system with objects.
background It is a proximity diffuse system which focuses the light beam such that the
luminous spot being reflected back to the photo-sensitive receiver is at a distance
suppression equal to that of the object to be detected. By relating to the distance of this spot,
the sensor will differentiate the object from the background.

Object 1 Object 2
Transmitter

Background

Back- Non
ground
spot detection
Detection
threshold Object
spot 1
Detection
Object
spot 2

Recommended trajectories of objects


Setting-up
recommendations

Recommended Recommended Not recommended

179
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Specific Systems - General
Specific Systems - General

Fiber optics The fiber optic acts as a light conductor. Light rays entering the fiber at a certain
Principle angle are conveyed to the required place, with minimum loss.

1 2
Photoelectric Sensors

1 core 2 sheath

Plastic fibers The core of the fiber is flexible plastic (PMMA). There is
usually a single fiber, 0.25 to 1 mm,
depending on the model.
They are used with amplifiers transmitting red light.
Minimum bend radius:
-10 mm for fiber with 0.25 mm core,
-25 mm for fiber with 1 mm core.
Advantage: Fibers can be cut to the required length.

The core of the fiber is silica. For maximum flexibility, each


Glass fibers fiber comprises numerous strands of approximate diameter
50 µ.
They are used with amplifiers transmitting infra-red or red
light.
Minimum bend radius:
-10 mm with plastic sheath,
-90 mm with stainless steel sheath.
Advantages:
-suitable for use in temperatures up to 250° C,
-stainless steel sheathed fibers provide
protection against mechanical impacts and
crushing.

Separate amplifier.
XU 3537

Specific aspects
H00
D-

-Compact.
t
-Detection of very small
objects.
-Precise detection.

Optical heads Separate amplifier.


Specific aspects -Very small detection head.
-Extensive range of heads
(fork, extra flat, convergent,
etc.) for specific applications.
-Detection of small objects.

Proximity Detection of color index mark on contrasting plain color background. Principle
Detection of of operation based on the difference between the colors (contrast) of the
diffuse system contrasting colors background and index mark in green or red light. The stronger the contrast
for color mark between the colors, the higher the difference
between the received signal strengths and the more reliable the
reading detection.

180
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Outputs and Wiring
Outputs and Wiring

2-wire BN AC or • Not protected against overload


2-wire AC or AC/DC AC/DC
and short-circuit.
• Light or dark switching output
BU AC or
AC/DC function, depending on model.

Photoelectric Sensors
3-wire BN + • Protected against overload and
3-wire DC PNP short-circuit.
BK
PNP or NPN type • 4 models:
BU – - PNP light switching,
- NPN light switching,
BN + - PNP dark switching,
NPN
BK
- NPN dark switching.

BU –

OG • Protected against overload and


3-wire DC BN + short-circuit.
PNP or NPN type, light PNP • 2 models:
BK
or dark programmable - PNP light/dark programmable
switching,
switching BU –
- NPN light/dark programmable
BN + switching.
NPN • Light or dark switching program-
BK
ming by means of connecting
BU – orange wire (OG) to either:
- brown wire (BN) for light
OG
switching, or
- blue wire (BU) for dark
switching.

5-wire BK AC/DC • Light switching or light/dark


5-wire AC/DC OG programmable switching,
output relay RD depending on model.
BN
BU AC/DC • AC or DC supply with wide
voltage range.
• 1 N.C./N.O. output relay, either 2 A
(cos ϕ = 1) or 0.5 A (cos ϕ = 0.4).

Analog output + • Analog output sensors are


Output voltage 3
4 based on a proximity diffuse
system with background sup-
Vs pression and provide an output
D
signal proportional to the dis-
6
tance of the object from the
1 – sensor (signal not dependent on
the reflection coefficient of
+ the object).
Output current 3
5
• 2 output configurations possible
on the same unit:
- output voltage: the output
D voltage varies between 0 and
6 10 V, in proportion to the
mA
1 – sensor-object distance,
- output current: the output
current varies between 4 and
20 mA, in proportion to the
sensor-object distance.

181
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Outputs and Connections
Outputs and Connections

Output
Light switching:
functions beam received
= output ON
Thru-beam and
retroreflective systems:
OFF
Photoelectric Sensors

Output ON = no object present.

ON

ON
Proximity diffuse system:

Output ON = object present.

OFF

Dark switching:
beam not received
(broken)
= output ON Thru-beam and
ON
retroreflective systems:

Output ON = object present.

OFF

Proximity diffuse system:


OFF

Output ON = no object present.

ON

Connection Factory fitted molded cable, good protection against splashing liquids.
Pre-cabled
methods

Ease of installation and maintenance.


Connector

Flexibility, cable runs to required length.


Screw terminals

182
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Complementary Functions
Complementary Functions

Output signal Some models of XUJ, XUE and XUV sensors incorporate an
Principle adjustable time delay.
time delay The following configurations are possible:
- light switching output, time delay on beam break,
- dark switching output, time delay on beam break,
- light switching output, time delay on beam make,
- dark switching output, time delay on beam make.

Photoelectric Sensors
Delay on beam make Delay on beam break

Thru-beam system Thru-beam system

Retroreflective system Retroreflective system

Object leaves detection zone: beam Object enters detection zone: beam
made broken

Proximity diffuse system Proximity diffuse system

Object enters detection zone: beam Object leaves detection zone: beam
made broken

The time delay is triggered as the beam is made and the output will not change
Time delay on beam state until the preset time (T) has elapsed. If the beam is
make broken and re-made during this period, the timer resets to zero.
Receiver state
(beam made/
t
beam broken)

Time delay t
period T

1
Light switching
output t
0

Dark switching 1
output t
0

The time delay is triggered as the beam is broken and the output will not change
Time delay on beam state until the preset time (T) has elapsed. If the beam is made and re-broken
make during this period, the timer resets to zero.
Receiver state
(beam made/
t
beam broken)

Time delay t
period T T

Light switching 1
output t
0

Dark switching 1
output t
0

183
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Complementary Functions
Complementary Functions

One shot function The one shot function is an extension of the time delay function and can
Principle either be on beam make or on beam break.
As the beam is made or broken, the output of the sensor immediately
changes state and remains in this condition during the preset time T,
irrespective of further beam makes or breaks.
After the preset time T has elapsed the output returns to its initial state,
until the next beam make or beam break.
Photoelectric Sensors

Time delay and Sensor type Time delay Monostable Time delay
Sensors incorporating function function
one shot function feature
-

XUJT••••• Adjustable
0.25 to
and/or c
15 s

XUET••••• Adjustable
q 0.03 to 1 s
or a or a or 1 to 60 s

XUVH••••• 40 ms
XUVJ••••• fixed

XUVF••••• 40 ms
fixed

XUVT••••• Adjustable
q 0.03 to 3s or 1
or a or a to 60 s

cTime delay on beam make and/or beam break.


aSwitchable selection of beam make or beam break.
qSwitchable selection of time delay or monostable.

Beam break test For verification of correct operation of the sensor. A test input enables the transmitted beam to be broken in order to verify
that the output of the sensor changes state. This function is incorporated in sensors type XUM and XUV.

BN + BN +

VI VI

BU – BU –

Beam made Beam broken

184
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Complementary Functions
Complementary Functions

Verification of Signal 1,2 A red LED illuminates when the intensity of the light beam
level 0,81 at the receiver is no longer strong enough to ensure correct
correct operation of the sensor. This being the possible result of
operation Red LED
dirty lenses, excessively polluted atmosphere, disturbance
of optical alignment, etc.
This function is incorporated in retroreflective and
LED off LED on thru-beam system sensors type XU•B18,

Photoelectric Sensors
XU•M18 (DC), XUM, XUJ, XUD and XUV.

Signal 1,2 In addition to the red LED indicting loss of received beam
level 1
0,8 strength, a warning output is available for
remote signalling. The output signal is delayed by 160 ms to
eliminate temporary conditions.
Red LED
This function is incorporated in retroreflective and
t t
thru-beam system sensors type XUM, XUJ and XUV.
Warning 1
output 0

LED off LED on

Optical Signal 1,2 A green LED assists setting-up by illuminating when


level 1 optimum optical alignment of the sensor is achieved.
alignment aid 0,8
This function is incorporated in sensors type XUJ, XUE,
XUD and XUV.
Red LED

Green LED
Optimum
alignment

LED off LED on

Detection of These retroreflective system sensors, with low


hysteresis, are specifically designed for detecting
transparent transparent object materials, such as:
objects - PET and PVC bottles and receptacles,
- clear glass bottles, etc.,
- PE (polyethylene) films.
Visible red beam transmission.
They are used in conjunction with a close range
reflector, type XUZC24 or XUZC50.
The sensing distance of the sensor depends on the reflector
used.
The sensor-reflector distance depends on both the reflector
used and the material to be detected.

185
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Complementary Functions
Complementary Functions

Synchronization The synchronization input is an additional wire which is used externally to either activate or deactivate the sensor. When the
sensor is deactivated (blocked) its output is OFF, irrespective of the presence or absence of an object. This synchronization
inputs input is incorporated in amplifiers for use with optical sensing heads (type XUV).

PNP type sensors + Synchronization input open


Photoelectric Sensors

PNP
Sensor deactivated (blocked)

Output OFF

+
Synchronization input connected to “+”
PNP
Sensor activated

Normal operation of sensor


– and associated output

+
NPN type sensors Synchronization input connected to “–”
NPN
Sensor deactivated (blocked)

Output OFF

+ Synchronization input open


NPN
Sensor activated

Normal operation of sensor


– and associated output

Application example: Verification of cork presence in bottle


The synchronization feature makes it possible to verify the presence of a cork in a bottle and also, to feed this information to
a PLC in the form S = no cork present. This is achieved by two detections: “presence of bottle” (synchronization sensor 2)
and “absence of cork” (optical sensing head 3).
Advantages:
• Very fast processing speed (unrelated to cycle time of PLC).
• Saving use of PLC input.
• This delocalized function can be used in an autonomous way, without a PLC, to directly control an
actuator for the removal of a defective product.

BK 1 Amplifier type XUV (PNP).


2 Proximity diffuse system light switching
PNP type photo-electric sensor
3 (detection of bottle presence/absence).
1
3 Convergent optical sensing head type
XUVN02428, (detection of cork
presence/absence).
BK = output signal wires from amplifier 1
and sensor 2.
GR = synchronization input wire of
GR BK
S amplifier 1.
2

186
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Curves
Curves

Detection curves Ideal detection The zone indicates the


Thru-beam positioning tolerance of the receiver.
system The zone represents the
usable sensing zone of the system.
T R
Any opaque object entering this zone
breaks the beam and causes the
d ≤ Sn sensor’s output to change state.

Photoelectric Sensors
Acceptable detection
T = emitter
R R = receiver

d ≤ Sn

Example: detection of an Special cases: It is possible to modify


object’s excessive height the usable beam to suit the
application, by masking the lenses.

1 Effective beam
2 Mask

1 2

Ideal detection The zone indicates the


Retroreflective positioning tolerance of the reflector.
and polarized The zone represents the
retroreflective usable sensing zone of the system.
systems Any opaque object entering this zone
breaks the beam and causes the
sensor’s output to change state.
Sn

Acceptable detection
T = emitter
R = receiver

T/R

Sn

The zone represents that of


Proximity diffuse and the sensor’s sensitivity. All this zone
proximity diffuse with is usable: any sufficiently reflective
T/R object entering this zone, in the
background
direction of the arrow, will cause the
suppression systems Sn sensor’s output to change state. The
black line corresponds to a white
Object 20 x 20 cm surface and the blue line to a darker
surface. A test, using the object to be
detected, will enable calculation of
the zone of sensitivity in relation to
the object’s reflection coefficient.
90% white object
18% grey object

Proximity diffuse systems with


background suppression enable the
detection of colored objects, or
T/R objects with different reflection
coefficients, at virtually the same
Sn distance.
90% white object
Object 20 x 20 cm 6 % black object

187
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Curves
Curves

Gain curves The operating distance (Sa) is the assured operating distance of the sensor,
Principle taking into account the environment (dust, etc.) and the
reflector used.
Sa < Sn (Sn = nominal sensing distance).
The gain curve indicates the acceptable safety margin for a thru-beam or
retroreflective system sensor before jeopardizing its correct operation.
The gain is defined by the following ratio:
Photoelectric Sensors

signal received by the photo-transistor


gain =
signal needed for switching

Gain 1 corresponds to the minimum signal received which will cause the sensor’s
output to change state.

The following thresholds should be used, depending on the ambient conditions:


gain ≥ 5: slightly dusty environment,
gain ≥ 10: polluted environment, dusty ambient air, slight mist,
gain ≥ 50: very polluted environment, fog, smoke, etc.
The measured values are generally transcribed onto a log/log graph:
-the distances are shown by the x-axis,
-the gain is shown by the y-axis.
Note: The sensing distance varies with temperature.
The nominal sensing distances indicated on the reference/characteristic pages
for the various types of photo-electric sensors take these variations into account,
within the temperature limits shown.

Thru-beam system: XUJM1000 + XUJM100314


Examples of excess (measurement made at ambient temperature + 25° C).
gain curves

500 Nominal sensing distance


Sn = 20 m

100
Polluted environment
50
(necessary gain = 10)
Sa ≤ 3 m
Very polluted environment
10
(necessary gain = 50)
5
Sa ≤ 1 m

1
0,1 0,2 0,4 0,8 2 3 5 10 15 20
0,6 1 4 6 D (m)

Retroreflective system: XUJM06031


(measurement made at ambient temperature + 77° F (25° C), with reflector
XUZC80).

Nominal sensing distance


40 Sn = 12 m
30 Polluted environment
20
(necessary gain = 10)
10 Sa ≤ 5 m

1
0,2 0,6 1 2 4 6 8 10
0,1 0,4 0,8 3 5 9 D (m)

188
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Standards and Certifications - Parameters Related to the Environment
Standards and Certifications - Parameters Related to the Environment

Influence of climatic Standard photo-electric sensors are designed to have a high immunity to
Ambient light ambient light.
environment

Photoelectric Sensors
Note: Caution should be taken, however, in the event of pulsed lights (neon signs,
flashing beacons, flash lights, etc.).

If the operating temperatures indicated on the reference/characteristic pages for


Dust, fumes, the various sensors are not adhered to, the sensing distances will be affected
pollution, and thus jeopardize the correct operation of the unit.
temperature,
humidity Behavior in environments with high
levels of interference:
- retroreflective system: risk of
unreliable operation,
- proximity diffuse system: not
recommended,
- thru-beam system:
recommended.
Correction coefficients to be applied to
sensing distances indicated:
1: clean environment,
0.6: lightly polluted environment,
0.25: moderately polluted environment,
0.10: heavily polluted environment
(for thru-beam system).

3 Outdoor mounting

2 Ensure that the sensor (and


reflector) are well protected.
Mount the sensor (and reflector) on a
thermally insulated surface to prevent
frost, ice or condensation affecting the
1 optical components.

1 Protective cover
2 Sun shade
3Thermally insulated support

Resistance to Owing to the very wide range of chemicals encountered in modern industry, it is very difficult to give general
guidelines common to all sensors. To ensure lasting efficient operation, it is essential that the chemicals coming into
chemicals in the contact with the sensors will not affect their casings and, in doing so, prevent their reliable operation. Refer to
environment “Enclosure Materials” on the specification pages relating to the various sensor models.

Resistance to shock The sensors are tested in accordance with the standard IEC 60068-2-27.

Resistance to The sensors are tested in accordance with the standard IEC 60068-2-6.

vibration
Degrees of Please refer to the reference/characteristic pages for the various sensors.

protection IP67: Protection against the effects of immersion, tested in accordance with the standard IEC 60529. sensor
immersed for 30 minutes, in 1 m of water.
No deterioration in either operating or insulation characteristics is permitted.

189
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Specific Aspects of Electronic Detectors
Specific Aspects of Electronic Detectors

Terminology MA
Ir Leakage current (Ir)
The leakage current (Ir) corresponds to the current flowing through the sensor
when in the “open” state.
XU Characteristic of 2-wire type photo-electric sensors.

Voltage drop (Vd)


Vd
Photoelectric Sensors

The voltage drop (Vd) corresponds to the voltage at the sensor’s


V
terminals when in the “closed” state.
XU (Value measured at nominal current rating of sensor).
Characteristic of 2-wire type photo-electric sensors.

Supply voltage V on
First-up delay
Detector operational at state 1
The time (t) between the connection of the power supply to the
Detector at state 0 photo-electric sensor and its fully operational state.
t

Delays
• Response time (Ra):
Ra Rr The time delay between entry of an object into the operating zone of
the sensor, and the subsequent change of output state.
This parameter limits the speed and size of the object.
• Recovery time (Rr):
The time delay between an object leaving the operating zone,
in which it is being detected, and the subsequent change of
output state.
This parameter limits the interval between successive objects.

Supply Check that the voltage limits of the sensor are compatible with the rated voltage
Photo-electric of the AC supply used.
detectors for
AC circuits
(AC and AC/DC models)

DC source: Check that the voltage limits of the sensor and the
Photo-electric sensors acceptable level of ripple, are compatible with the supply used.
for DC circuits

AC source (comprising transformer, rectifier, smoothing capacitor):


The supply voltage must be within the operating limits specified for the sensor.
Where the voltage is derived from a single phase AC supply, the voltage must be
rectified and smoothed to ensure that:
- The peak voltage of the DC supply is lower than the maximum
voltage rating of the sensor.
Peak voltage = nominal voltage x √2
- The minimum voltage of the DC supply is greater than the
minimum voltage rating of the sensor, given that:
∆V = (I x t) / C
∆V = maximum ripple: 10% (V),
I = anticipated load current (mA),
t = period of 1 cycle (10 ms full wave rectified for a 50 Hz supply
frequency voltage),
C = capacitance (µF).
As a general rule, use a transformer with a lower secondary voltage (Ve) than the
required DC voltage (V).
Example:
18 Vac to obtain 24 Vdc,
36 Vac to obtain 48 Vdc.
Fit a smoothing capacitor of 400 µF minimum per sensor, or 2000 µF minimum
per ampere required.

190
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Specific Aspects of Electronic Detectors
Specific Aspects of Electronic Detectors

Types of output These sensors are wired in series with the load to be switched.
2-wire Because of this they are subject to:
- a leakage current (in the open state),
- a voltage drop (in the closed state).
AC/DC
For polarized (polarity conscious) DC sensors, the supply polarities must be
observed.
AC/DC For non polarized (not polarity conscious) AC sensors, the supply

Photoelectric Sensors
polarity load connections to + or – are immaterial.
Advantages:
- The sensors can be wired in the same way as mechanical limit switches.
- For AC and AC/DC models, they can be connected to either positive (PNP)
or negative (NPN) logic inputs. No risk of incorrect connections.
But:
Check the possible effects of residual current and voltage drop on the input
device being controlled (pick-up and drop-out thresholds).

These sensors comprise 2 wires for the DC supply and a third wire for
3-wire transmission of the output signal.
- PNP type: switching the positive side to the load,
+ - NPN type: switching the negative side to the load.

PNP
The programmable universal sensors provide a choice of function,
either: PNP/N.O., PNP/N.C., NPN/N.O., NPN/N.C.

+ Advantages:
- Programmable output signal, no residual current, low voltage drop.
NPN - N.O. + N.C. versions, for solid state input coincidence control
– (4-wire type: XUJ and XUE).
- Programmable models, reduced stock levels.
But:
Certain models must only be used with their designated PNP or NPN type of
logic input.

Sensors incorporating output relay.


5-wire Both AC and DC sensors have electrically separate supply and output circuits.
AC/DC Advantages:
- Higher output current, no voltage drop, no residual current.
- Flexibility of output voltage.
- Sensors suitable for use with PLCs.
AC/DC
But:
Reduced service life and operating rate.
Example: XUJ, XUE, XUL sensors incorporating output relay
Number of operating cycles Number of operating cycles

1,5 1,5
107 10
7

106 106
220 V
110 V

220 V

110 V
48 V
24 V

48 V
24 V

0,01 0,1 1 10 0,01 0,1 1 5 10


i(A) i(A)
Service life for cos ϕ = 0.4 Service life for cos ϕ = 1

191
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors

Connection The following points should be taken


2-wire type into account:
in series • Multivoltage sensors cannot be
connected in series.
• When in the open state, each
sensor will share the supply
voltage, i.e.:
U supply
Photoelectric Sensors

U sensor =
n sensors

(based on the assumption that


each sensor has the same
residual current value).
U sensor and U supply must
remain within the sensor’s
voltage limits.
• If only one sensor in the circuit is
in the open state, it will be
supplied at a voltage almost equal
to the supply voltage.
• When in the closed state, a small
voltage drop is present across
each sensor. The resultant loss
of voltage at the load will be the
sum of the individual voltage
drops and, therefore, the load
voltage should be selected
accordingly.

Not recommended. Prone to


3-wire type incorrect operation, must be pretested.
The following points should be taken
into account:
• Sensor 1 carries the load current
in addition to the no-load current
consumption values of the other
sensors connected in series. For
certain models, this connection
method is not possible unless a
current limiting resistor is used.
• When in the closed state, each
sensor will produce a voltage
drop and, therefore, the load
voltage should be selected
accordingly.
• As sensor 1 closes, sensor 2
will not operate until a certain time
“T” has elapsed (corresponding to
the first-up delay) and likewise for
the following sensors in the
sequence.
• “Flywheel” diodes should be used
when the load being switched is
inductive.

For these sensors the supply and


5-wire type output circuits are electrically
separate.
• The sensor/relay contact
galvanic isolation is 1500 to
2500 V, depending on the model.
• The maximum voltage across
each contact is 250 V.

192
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors

Connection 2 and 3-wire type sensors


Wiring sensor with U
in series mechanical contact The following points should be taken
into account:
(continued) • When the mechanical contact is
open, the photo-electric sensor is
not supplied.

Photoelectric Sensors
• When the contact closes, the
sensor will not operate until a cer-
tain time “T” has elapsed (corre-
sponding to the first-up delay).

5-wire type sensors


The following points should be taken into account: In scheme 1, as the external
series contact opens, the voltage transient caused by the breaking of the
inductive load will appear inside the sensor and, if greater than the
recommended max. insulation voltage, may cause a “flashover” within the
sensor. The return path of this voltage will be back to one line of the supply,
through the sensor, and should “flashover” occur anywhere on the printed circuit
board, severe damage could occur. It is recommended to use schemes 2 or 3.
AC AC AC

AC AC AC
Scheme 1 Scheme 2 Scheme 3

Connection in The use of sensors wired in parallel,


2-wire type either between themselves or together
parallel with mechanical contacts, is not
recommended.
Should one of the sensors be in the
closed state, the sensor in parallel will
be “shorted-out” and no longer
supplied. As the first sensor passes
into the open state, the second sensor
will become energized and will be
subject to its first-up delay.
The configuration is only permissible
where the sensors will be working
alternately.
This method of connection can lead to
irreversible damage of the units.

No restrictions.
3-wire type The use of “flywheel” diodes is
recommended when an inductive load
(relay) is being switched.

No restrictions.
5-wire type For these sensors, the supply and
output circuits are electrically separate.
The sensor/relay contact galvanic
isolation is 1500 to 2500 V, depending
on the model.
The maximum voltage across each
contact is 250 Vac, depending on the
model.

193
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors

Wiring advice No limitation up to 200 m or up to a line capacitance of ≤ 0.1 µF (characteristics


Length of cable of sensor remain unaffected). It is, however, advisable to take into account
voltage drop on the line.

Telemecanique photo-electric sensors are immune to electrical


Separation of control interference encountered in normal industrial conditions.
and power cables
Photoelectric Sensors

Where extreme conditions of electrical “noise” could occur (large


motors, spot-welders, etc.) it is advisable to protect against transients in the
normal way:
- suppress interference at source,
- limit the length of the cable,
- separate power and control wiring from each other,
- filter the supply,
- use twisted and shielded cable pairs for output signals.
In cases necessitating intervention at the machine (e.g.: arc welding), disconnect
the sensors.

1 1

≥10
cm
2
2
1 Control cable
2 Power cable

The level of dust and damp protection depends on how carefully the screws,
Dust and damp seals, cable glands, blanking plugs, etc. have been tightened.
protection of cable To ensure efficient dust and damp protection, use the correct diameter cable for
glands the cable gland used.

AC supply 2-wire type sensors cannot be connected directly to an AC supply.


This would result in immediate destruction of the sensor and considerable
danger to the user.
An appropriate load (refer to the instruction sheet supplied with the sensor) must
always be connected in series with the sensor.

Capacitive load At switch-on, it is necessary to limit (by resistor) the charging current of the
capacitive load C.
(greater than -R The voltage drop in the sensor can also be taken into account by
0.1 µF) subtracting it from the supply voltage for calculation of R.
-C V (supply)
R=
I max. (sensor)

Load + If the load comprises an incandescent lamp, the cold state resistance can be 10
times lower than the hot state resistance. This can cause very high current levels
comprising an a on switching.
incandescent –
Fit a pre-heat resistance in parallel with the photo-electric sensor.

lamp + V2
R= x 10
P
a V = supply voltage
P = lamp power

194
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors

Problem Possible causes Remedy

The sensors output will not Output stage faulty or complete failure Check that the sensor is compatible with the supply being used.
change state when an object of the sensor (in either case, the Check the load current characteristics:
enters the operating zone sensor must be replaced), or the short- - if load current I ≥ maximum current, a relay should be interposed
circuit protection has tripped between the sensor and the load,
- if load current I ≤ maximum current, check for wiring faults (short-circuit).

Photoelectric Sensors
In any case, a “quick-blow” fuse should be placed in series with the sensor.

Wiring error Verify that the wiring conforms to the wiring shown on the sensor
label or instruction sheet.

Supply fault Check that the sensor is compatible with the supply (AC or DC).
Check that the supply voltage is within the voltage limits of the sensor.
Remember that with rectified, filtered supply: U peak = U nominal x √2.

With a retroreflective system: The retroreflective system must operate in conjunction with a reflector.
- incorrect use of reflector, Respect the operating distances. Clean the reflector.
- poor state of reflector Replace the reflector if it has been damaged.

False or erratic operation, with or Influence of reflective background or Refer to the instruction sheet supplied with the sensor. For adjustable sensors,
without the presence of an object surface of the object (stray reflections) reduce or increase the sensing distance.
in the operating zone

Operating distance poorly defined for Apply the correction coefficients.


the reflector or object used Realign the system.
Clean the reflector or, if damaged, replace it.

Influence of immediate environment Check the cleanliness of the lenses and reflector.
Fit a lens hood, where required.

Influence of transient interference on Ensure that any DC supplies, when derived from rectified AC, are correctly
the supply lines. smoothed (C > 400 µF).
Separate AC power cables and DC low level cables.
Where very long distances are involved, use suitable cable: screened and twisted
pairs of the correct cross-sectional area

Equipment liable to emit Position the sensors as far away as possible from any sources of interference.
electromagnetic interference

Response time of the sensor too slow Check the suitability of the sensor for the object to be detected.
for the particular object being detected If necessary, select a photo-electric sensor with a higher switching frequency.

Influence of high temperature Eliminate sources of radiated heat, or protect the sensor casing with a heat shield.
Realign, having adjusted the temperature around the fixing support.

No detection following a period Vibration, shock Realign.


of service Change the support or protect the sensor.

Contact deterioration On an inductive load, use an RC suppressor connected in parallel with the load.
Example: LA4D•••
To eliminate contact contamination, the minimum current recommended is 15 mA.
The relay output models are not recommended for rapid counting of objects since
their service life is too short.
Use models with solid state output.

Dusty atmosphere Clean the lenses and reflectors with a soft cloth.

195
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Photoelectric Sensors

196
© 1997-2002 Schneider Electric All Rights Reserved 10/02