55000
5000 9000 9000 9000 9000 9000 5000
4500 4500 4500 4500 4500 4500 4500 4500 4500 4500
200
200
0.40mm THK. PRE-PAINTED AND PREFORMED G.I. END
TOP LINE OF ROOF BEAM/ FLASHING G.I. SHEET WITH TOTAL COATED THICKNESS
600 800
DECK ROOF FLOOR LEVEL OF 0.43 - 0.45 mm THK.
1400
R
CEILING LINE/CORRIDOR F F F F F F F F F F F F F F F F F F F F
D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 EWF-1
3150
1500
SECOND/CORRIDOR FLOOR LINE 20 X 20 mm GROOVE LINES
600
R
F F F F F F F F F F F F F F F F F F F F
(1 @ 900 mm, 1@ 700 mm
EWF-1a HIGH FROM RAMP/ LANDING FLOOR LEVEL) FULLY WELDED ON
3150
R
D-3a D-3 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-1 W-2 W-2 D-1 D-3 D-3a
SIDE ( SEE DETAIL)
R
750
GROUND/CORRIDOR FLOOR LINE
200
300
(1 @ 900 mm, 1@ 700 mm 150 mm THK. CHB EXTERIOR WALL RAILING (BELOW R.C. BENCH)
HIGH FROM RAMP/ LANDING FLOOR LEVEL) FULLY WELDED ON
EMBEDDED ON CHB RAILING SPACED @ 1050 mm O.C
AT 600 mm HIGH WITH PLAIN CEMENT PLASTER PAINTED
FINISH (SUBMIT COLOR SCHEMES FOR APPROVAL)
LEGEND:
SIDE ( SEE DETAIL) - TYPICAL TO OTHER SIDE
R REVISION OF DRAWING DETAILS (1/23/2018) SCHEDULE OF WALL FINISHES :
1 FRONT ELEVATION NOTE: - REVISION OF CORRIDOR RAILING AT GROUND FLOOR
(FROM 150 mm THK. CHB RAILING TO REINFORCED MARK WALL DESCRIPTION
SCALE 1: 100 M. CONCRETE BENCH) ADAPTING THE PROPOSED DEPED
A-5 - FOR SCHOOL BUILDING SITE LOCATED NEAR SEA BOARDS OR COASTAL DESIGN. 150 mm THK. CHB EXTERIOR WALL WITH PLAIN CEMENT PLASTER
AREAS PRONE TO CORROSION ON G.I. ROOFING, CORRUGATED ASPHALT - REVISION OF CORRIDOR RAILING AT SECOND AND EWF - 1 PAINTED FINISH
ROOFING SHEETS (3.0 mm THK. - BITUMINOUS - CELLULOSE FIBRES CAN BE THIRD FLOOR ADAPTING THE PROPOSED DEPED DESIGN. (SUBMIT COLOR SCHEMES FOR APPROVAL)
USED AS ALTERNATE ROOFING MATERIALS). - REVISION OF JAULOUSIE WINDOW (W-2) - FROM THREE (3) 150 mm THK. CHB EXTERIOR WALL RAILING WITH PLAIN CEMENT
PANEL WINDOWS REDUCED INTO TWO (2) PANEL WINDOWS. EWF - 1a PLASTER PAINTED FINISH
- FOR COLUMNS AND BEAMS SIZES REFER TO STRUCTURAL SHOP DRAWINGS. (SUBMIT COLOR SCHEMES FOR APPROVAL)
- REVISION OF PARAPET WALL (R.C. GUTTER) FROM 100 mm THK.
CHB TO 100 mm THK. REINFORCED CONCRETE
100 mm THK. RC PARAPET WITH PLAIN CEMENT PLASTER PAINTED
- ADDITIONAL CANOPY (REINFORCED CONCRETE) ALONG MAIN EWF - 2 FINISH (SUBMIT COLOR SCHEMES FOR APPROVAL)
ENTRANCE, AS RECOMMENDED ON THE PROPOSED DEPED
DESIGN
100 mm THK./ 150 mm THK. CHB INTERIOR WALL WITH PLAIN CEMENT
- ADDITIONAL MEDIA AGUA (REINFORCED CONCRETE SUN IWF - 1 PLASTER PAINTED FINISH
BREAKER) ABOVE WINDOW (W-1) AT REAR.
(SUBMIT COLOR SCHEMES FOR APPROVAL)
- REVISION OF TOILET'S WALL & FLOOR FINISHES
- (IWF-2) FROM 200 X 200mm VIT. GLAZED WALL TILES FINISH 200 X 200 mm VITRIFIED GLAZED TILE WALL FINISH
TO 300 X 300mm VIT. GLAZED WALL TILES FINISH IWF - 2
- (FL-3) FROM 200 X 200 mm VIT. UNGLAZED TILES FLOOR FINISH (SIZE & OR COLOR FOR APPROVAL BY THE END-USER) R
TO 300 X 300mm VIT. UNGLAZED TILES FLOOR FINISH - TYPICAL ON ALL TOILET WALLS
13 12 11 10 9 8 7 6 5 4 3 2 1
55000
5000 9000 9000 9000 9000 9000 5000
0.40 mm THK. (BASE METAL THICKNESS) WITH TOTAL THICKNESS
OF 0.43 - 0.45 mm THK. (WITH PAINT) CORRUGATED G.I. SHEET 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500
ROOFING 0.40mm THK. PRE-PAINTED AND PREFORMED G.I. END
TOP LINE OF PARAPET FLASHING G.I. SHEET WITH TOTAL COATED THICKNESS
OF 0.43 - 0.45 mm THK.
600
R
D-5 D-5
TOP LINE OF ROOF BEAM/
DECK ROOF FLOOR LEVEL
EWF-1
W-3 W-4 W-4 W-3
1475
925
SECOND/CORRIDOR FLOOR LINE R
EWF-1
F F F F F F F F
3150
1475
925
GROUND/CORRIDOR FLOOR LINE
300
2 REAR ELEVATION
SCALE 1: 100 M.
A-5