EXPERIMENT No: 1

TITLE:

“To Verify theImpulse Momentum Principle for a jet of water striking on 90,120 and 180
deflection and to investigate the effect of velocity of flow on impulse force of the jet for
various deflection ”
INTRODUCTION:

The impulse-momentum states that the change in momentum of an object equals the impulse applied to
it. The impulse-momentum theorem is logically equivalent to Impact of jet apparatus is a very simple
apparatus which directly measure the impulse force of the jet by an equivalent weight placed I the pan.

OBJECTIVE:
The objective of this experiment is to determine the Impulse Momentum Principle.

PROCEDURE:

 Level the apparatus.


 At zero load and zero flow rate adjust the pointer.
 Switch on the pump.
 Place the load and gradually open the valve till the collar reaches its original position.
 Note down the time to collect the known volume of water in jet.
 Repeat the previous steps for 100gm, 150gm, and 200gm load increment till the valve is
completely open.

RECORTED DATA:
Sr. Volume Time Weight
(m3) (sec) (kg)
1 0.002 9.82 0.10
2 0.002 6.31 0.20
3 0.002 4.29 0.35
DATA ANALYSIS:

Coefficient of Discharge Cd

Deflection Sr. Mass F=mg Time Q V F=KPQV Error


Ѳ

(kg) (N) (sec) (m3/s) (m/s) (N) %


1 0.10 0.981 9.82 0.00020 4.05 0.82 19.63
Flat
Rate 2 0.20 1.962 6.31 0.00031 6.31 2.00 1.9

3 0.35 3.4335 4.20 0.00047 9.27 4.32 20.52

1 0.05 0.491 8.86 0.00022 4.489 1.013 51.53


90
2 0.1 0.981 6.54 0.00030 6.083 1.860 47.26

3 0.2 1.96 3.70 0.00054 10.752 5.674 65.15

1 0.1 0.981 9.5 0.00021 4.2 1.323 25.8


120
2 0.2 1.962 8.43 0.00023 4.6 1.584 24.1

3 0.35 3.4335 5.11 0.00039 7.8 4.563 24.7

1 0.10 0.981 14.56 0.00013 2.74 0.757 29.50


180
2 0.20 1.962 8.52 0.00023 4.65 2.179 9.93

3 0.35 3.4335 5.48 0.00036 7.26 5.3 35.34

DISSCUSSION:

 Serial number.
 Mass is denoted in kg.
 Experimental force is calculated in N.
 Time is measured in sec.
 Discharge is denoted in (m3/s) .
 Velocity is calculated in (m/s).
 Theoretical force is determined.
 Error is calculated.

CONCLUSION:

 At the deflection of flat plate error is 19.63%.


 At the deflection of 90 error is 51.53%.
 At the deflection of 120 error is 25.8%.
 At the deflection of 180 error is 29.50%.