ot u"rl, Starken AAC Btock Watt - lnfill Watt (Non-toad bearing) lnstattation ,uruu,
"l \ \ \
<D
a)
s
o

O) lmportant
o)

a Block wall installation notes


to
O)

1. Thick bed levelling mortar should be nominally 10mm to 30mm


> thick (Final mortar bed thickness after blocks are tapped in
o place). Allow levellinq mortar to set at least for min. of four
D hoursbefore commencing the remaining block courses. Longer
o hours may be required depending on weather condition and
\s
o
mortar mix ratio (water content).
tu\
2. Provide 10mm to 30mm gap between block wall and columns/
stiffeners.
:t 3. Allow a minimum of 20mm clearance (up to 50mm) between
S block wall and beam/ slab soffit.
s
4. Use cement sand mortar having a mix ratio of 1:7 to 1:8 for f illing
2o the clearance gaps and thick bed leveling purpose.

o 5. AAC blocks must be installed in a stretcher bond pattern with a


o) minimum 100mm block overlap. Blocks are typically cut to
a 300mm length to achieve 300mm vertical joint offset.
o
{
o) 6. At the junction of block wall/ siiffener or column, fix ST2 Ties
vertically at 600mm centres, first and last courses.
I
7. At the junction of block wall/ soffit of slab or beam, install ST2
Ties horizontally at 1200mm centres, first and the last blocks of
6
)o the final course.

N 8. Ensure 2mm to 3mm thickness of Thin Bed Adhesive (TBA) at


block vertical and horizontal joints. Joints should be completely
filled with adhesive. Occasionally, approximately 5mm thick
joints may occur due to block dimensional toloerance-
9. Clean any excess adhesive within 1 to 2 hours after block laying
is recommended.
'10. Where required by design, clearance gaps (block wall to soffit)
can be adjusted to suit and/or filled with compatible suitable
sealand instead of cement/ sand mortar.
1 1. Ensure the first block course is true and level before proceeding
to the subsequent courses. Use suitable apparatus such as spirit
level, laser levelling and alignment instrument, e.t.c.
12. AIIow wet blocks io dry before insiallation.
13. lvlinimum block length allowed to be installed within each block
course is 100mm.
14. Freshly erected block wall must be protected from rain or water
prior to curing or skim coating/ rendering.
15. Check the level and alignment of subsequent courses
occasionally.
'16. Vertical reinforced concrete stlffeners may be spaced to
accomodate up io 4m AAC wall length.
17. lf block wall height exceeds 4500mm in height, provide
horizontal strffener before laying the remaining blocks above the
4500mm level.
18. Reinforced concrete beams, columns, slabs and stiffeners must
be designed by qualified elgineer.

19. The details provided in this manual are only applicable io internal
wall only for service load of 0.25kPa- For external wall and
applications required to withstand more than 0.25kPa load,
stiffeners may be spaced less than 4m. Refer Starken technical
department for advice.
20. When used externally and subjected to wind load, stiffeners
spacing should be reduced to engineer's specification.

o5
o
q
$
a
e
o
Block lnstallation Guidelines {!
s
q

Step 1 -Setting up & levelling 6


Note: Verticality alignment string must be installed at least at each wall end or corner
a)
a
'o
a
o
o
3
RC Beam/ Slab s
Straightness alignment string =
Verticality
alignment 1Omm to 30mm thick bed 6
string cement/ sand mortar levelling
course (1:7 to 1:B mix ratio) \=o
over DPC o
Reinforced a
O
concrete stiffener
or column to
{
engineer's detail Damp proof course (DPC)r
c)
slip joint at ground level, +<
wet area, precast/ $
pre-stressed/ post-tensioned q
Reinforced concrete
slab or beam to reinforced concrete slabs
engineer's detail N
ot
s

Step 2 - First block course (laying first block)

RC Beam/ SIab First block set 1Omm to 30mm away from


Straightness alignment string
edge of column or stiffener. Apply adhesive to
block bottom surface before laying. Tap block
Verticality
with rubber mallet to align with levelling
alignment 1Omm to 30mm thick bed
string. Check with spirit level.
string cement/ sand mortar levelling
course (1:7 to 1:8 mix ratio)
Apply adhesive to block over DPC
Reinforced perpend before laying
concrete stiffener subsequeni blocks
or column to
engineer's detail Damp proof course (DPC)r
slip joint at ground level,
wet area, precast/
Reinforced concrete pre-stressed/ post-tensioned
slab or beam to reinforced concrete slabs
engineer's detail

*l l-' 10mm to 30mm gap filled with cement


sand mortar (1:7 to 1:8 mix ratio)

o6
CD

O)

o)
o

0r
q
BIock lnstallation Guidelines
0)

CJ)
il Step 3 - First block course (Laying subsequent blocks)
o

>
o
h
o
o
-
s RC Beam/ Slab
Straightness alignment string
ST2 Tie fied to column or
stiffener & bedded into adhesive
Verticality at block horizontal joint
= alignment 1Omm to 30mm thick bed
s= string cement/ sand mortar levelling
eo Lay the remaining first course (1:7 to 1:B mix ratio)
course blocks (Apply over DPC
Reinforced
o adhesive to block bottom
0) concrete stiffener
a. surface before laying)
o' or column to
o Damp proof course (DPC)/
engineer's detail
0)
slip joint at ground level,
:l
I=. Reinforced concrete
wet area, precast/
pre-stressed/ post-tensioned
slab or beam to reinforced concrete slabs
;- engineer's detail
-o
N

-*l l._ 10mm to 30mm gap filled with cement


sand mortar (1:7 to 1:8 mix ratio)

Step 4 - Laying subsequent blocks courses


Note: 1. Straightness alignment string should be moved upward as each block course progresses
2. Ensure mortar levelling course has achieve sufficient strength before laying the subsequent block courses.

Apply adhesive to top of


RC Beam/ Slab first course blocks and all
ST2 Tie fied to column or
stiffener & bedded into adhesive perpends of adjacent
Verticality at block horizontal joint blocks before placing the
alignment next blocks in position
string Cut block to 300mm length
to achieve stretcher bond Straightness alignment string
laying pattern (100mm min.
Reinforced
concrete stiffener block overlap)
or column to 10mm to 30mm thick bed
engineer's detajl cement/ sand mortar levelling
course (1:7 to 1:B mix ratio)
over DPC
Reinforced concrete
slab or beam to Damp proof course (DPC)/
engineer's detail slip joint at ground level,
wet area, precast/
pre-stressed/ post-tensioned
reinforced concrete slabs

-*lF- 10mm to 30mm gap filled with cement


sand mortar (1:7 to 1 :B mix ratio)

o7
G

o
Block lnstallation Guidelines l!
a
o
e

Step 5 - Final block course 6


S
Note: 1. The longer leg of ST2 Tie is sandwiched between block join and embedded into thin bed adhesive. s()
2. The shorter leg of ST2 Tie can be fix to RC Structure / Stiffener by one of the following methods: a
a. Gas-driven fastening system (Hilti / Ramset) E
$
b- Nylon wall plug (min. 6mm @) & suitable fastener
c. Hand-driven concrete nail (smm @ x 25mm long min.)
s
o
20mm to 50mm min. gap 3

RC Beam/ Slab
IT filled with lean mortar
having cement to sand
ratio of 1:7 to 1:8
s
E
I
N
S
-
c-- - r rvqu!v q( '200n-rr
,, \o
Verticality cert!'es honzontally. and sa
alignment firsr & last blocks of the
O
string frnal course
1Omm to 30mm thick bed {
cement/ sand mortar levelling
a)
Reinforced course (1:7 to 1:B mix ratio) t<
concrete stiffener ST2 Tie fied to column oi- over DPC CU

q
or column to stiffener & bedded into adhesive
engineer's detail at biock horizontal loint
N
ot
Reinforced concrete Damp proof course (DPC)/ I
slab or beam to slip joint at ground level,
engineer's detail wet area, precast/
pre-stressed/ post-tensioned
reinforced concrete slabs

I
I 10mm to 30mm gap filled with cement
I
-lF- sand mortar (1 :7 to 1:8 mix raiio)
I
I
I

I
I 1omm to 30mm gap filled
t with cement sand mortar
I (1:7 to 1:B mix ratio)
\

-l z.

Starken AAC Blocks


\
Fastener I
I
I

ST2 Tie !
I I
!:
t .'
RC Column --------t"+
\"\ ,"
\

o8
Edff
P. qr_
ur$q)
I I

,+-= -

6'
J I
cL

-\ ,"r0, Starken AAC Btock Watt - tnfilt Watt (Non-toad bearing) lnstattation uanuat

\ \ \
CD

O)
s
o

O)

q
Standard lnstallation Details
ND

@
q) Non-Load Bearing Starken Block Wall lnstallation (Figure 1)
*
o Note: 1. Cement to sand ratio is by volume
2. lf necessary or more practicle, reinforced concrete stiffener may also be constructed
after erection of block wal. Under such practice, provide adequate temporary support
! for the erected block wall to ensure its stability
o
B
o
\
o
Reinforced concrete ST2 Tie spaced at 1200mm centres horizontally,
s slab or beam to and first & last blocks of the final course
engineer's detail
20mm to 50mm min. gap

I
filled with lean mortar having
=
S
cement to sand ratio of
Q)\
1:7 to 1:B
2o
o E
T Reinforced concrete
a) E stiffener or column to
o- o
o engineer's detail
o' ro
o <-
0)
:.
:l
s_ c
'o) ST2 Tie spaced at
c 600mm centres
(s vertically, and first &
-o = last block courses
= N x
(E
Damp proof course (DPC)/
slip joint at ground level,
wet area, precast/
pre-stressed/ post-tensioned
reinforced concrete slabs

l_
I 10mm to 30mm gap filled
with cement sand mortar
(1:7 to 1:8 mix raiio)

Elevation View

11
a

ss
o
Standard lnstallation Details c5

$
LD

Detail I
Starken Block Wallto Golumn & Slab / Beam Soffit Detail (Figure 2) 6
Ai ST2 Tie, one end fixed to soffit of reinforced
'i
$
C)
-a
'o
concrete slab or beam and the other end embedded $
into adhesive at block perpend joint a
o
Reinforced
concrete slab or G
S
beam to
engineer's detail E

6
Reinforced concrete
20mm to 50mm min. gap
filled with lean mortar having stiffener or column to \o
=
cement to sand ratio of
engineer's detail sa
1:7 to 1:8 o
{{
2mm to 3mm thick ST2 Tie, one end fixed to c)
thin bed adhesive to reinforced conrete siiffener / t$
perpends
joints T| ru
allblock "E ,b;pmf column and another end q
and horizontat t"#'fl" embedded into adhesive at
,,,.,ffiSt"d, block horizontal joint N
starken AAC Brocks ffi ot
s
1Omm to 30mm gap filled
with cement sand mortar
(1:7 to 1:8 mix ratio)

;;; I
I
Starken Block Wallto Column & Floor Detail (Figure 3)
B I

1Omm to 30mm gap filled


with cement sand mortar
(1:7 to 1:B mix ratio)

Reinforced concrete 2mm to 3mm thick thin bed


stiffener or column to adhesive to all block perpends Starken AAC Blocks laid in
engineer's detail and horizontal joints stretcher bond pattern with
minimum 100mm block overlap
between courses
ST2 Tie, one end fixed to
reinforced conrete stiffener /
column and another end Damp proof course (DPC)/
embedded into adhesive at slip joint at ground level,
block horizontal joint wet area, precast/
pre-stressed/ post-tensioned
reinforced concrete slabs

Reinforced concrete slab or


beam to engineer's detail

12
5
CD

o)
0)
o

o) Standard lnstallation Details


0)

b
0l

o Ia-a/
o
E
o
o
Reinforced concrete
\= slab or beam to
engineer's detail

=
$-
= Fibre glass reinforcing tap Min. 20mm up to 50mm gap filled with
E (150mm wide) bedded into cement/ sand mortar (1:7 to 1 :B mix ratio)
skim coat/ render/ plaster
o
A)
o_ ST2 Ties, one end fixed to soffit of
o
o reinforced concrete slab or beam and 2mm to 3mm thick thin bed adhesive
tu
the other end embedded into adhesive to all block joints
-
s- at block perpend joint

Starken AAC Blocks laid in Skim coating or render to both sides


6 stretcher bond pattern as specified
o
,\,

l--1
Starken Block Wall & Beam Soffit Junction (Figure 5)

Reinforced concrete
slab or beam to
engineer's detail

Fibre glass reinforcing tap (150mm wide) Min. 20mm up to 50mm gap filled with
along beam-to-block wall junction cement/ sand mortar (1:7 to 1:8 mix ratio)
bedded into skim coat/ render/ plaster

ST2 Ties, one end fixed to soffit of


reinforced concrete slab or beam and 2mm to 3mm thick thin bed adhesive
the other end embedded into adhesive to all block joints
at block perpend joint

Starken AAC Blocks (Min. 100mm thick) Skim coating or render to both sides
laid in stretcher bond pattern as specified

13
o
a
CS

e
o
Standard lnstallation Details $
$
c)
q

Starken Block Wall & Stiffener Junction (Figure 6) 6


Note: Thisitemcanbeomittedifstiffenerisconstructedaftertheerectionafblockwallundersuchcircumstances, S
Block wall shauld terminate along the sides of the praposed stiffener or/ can be affset up to 30mm away
a
C)
a
'o
$
a
ST2 Ties, one end fixed to reinforced Starken AAC Blocks o
concrete stiffener/ column and another Reinforced concrete stiffener or laid in stretcher
3
end embedded into adhesive at block column to engineer's detail. bond pattern {E
vertical joint

\o
=
a
e
O
q

Fibre glass reinforcing tape


(150mm) bedded into skim
__r/il* --lF- 1
t
C)

CS

U)

///
coat/ render/ plaster
|
(\
o{
1Omm to 30mm gap filled ;xil.Tt::x:;:T,H'" s
with cement sand mortar
(1:7 to 1:8 mix ratio)

Starken Block Wall & Floor Junction (Figure 7)

Starken AAC Blocks laid in


rT 2mm to 3mm thick thin bed

r
stretcher bond pattern adhesive to all block joints

Skim coating or render to both 1Omm to 30mm thick


sides as specified thin bed cement/ sand
mortar levelling course
(1:7 to 1:B mix ratio)
over DPC

I
Damp proof course/ slip joint at
ground level, wet area, precast/ I

pre-stressed/ post-tensioned
RC Slabs

Reinforced concrete
slab or beam to
engineer's detail

14
=
b
q)
N
o

0) Stand ard Installation Details


o)

cn
tu Starken Block Wall Corners (Figure 8)
+
o - For Wall Without Horizontal RC Stiffener
Note: 1. This detail is applicable ta wall without horizontal stiffener only
2. For best results, install angle corner bead during application of skim coat or render
o
m
o
o

s=
Starken AAC Blocks
laid in stretcher
bond pattern
=
=
s
2o
o
o.
o
o
a)
Starken AAC Blocks tied
s- together by keying in full block
overlapping at each course

6
o
\)

lsometric View

Starken Block Wallto Block WallJunction (Figure 9)


- For Wall Without Horizontal RC Stiffener
Note: 1. This detail is applicable to wall without horizontal stiffener only
2. For best results, install angle corner bead during application of skim coat or render

Full overlapping at
alternate courses with
adjacent block wall

Starken AAC Blocks


laid in stretcher
bond pattern

lsometric View
15
o
$

o
Standard lnstallation Details a
CE

v)
e

Starken Block Wall & Other Masonry Wall Junction (Figure 10) 6
Note: This item can be omitted if stiffener is constructed after the erection ot block wall under such circumstances,
\a
block wall should terminate alang the sides of the proposed stiffener or/ can be offset up to 30mm away q)
a
'o
$
s
o
Non-load bearing wall by others Plaster or skim coat as
specified -(tr

ST2 Ties, one end fixed to reinforced Reinforced concrete stiffener


concrete stiffener/ column and another
end embedded into adhesive at block Starken AAC Blocks
o
vertical joint laid in stretcher s
bond pattern \o
o
a
o

o
+<
$
Fibre glass reinforcing tape CD

(150mm) bedded into skim


coat/ render/ plaster N
o
Skim coating or render to
'1Omm to 30mm gap filled
both sides as specified
with cement sand mortar
(1:7 to 1:8 mix ratio)
Plan View

Starken Block Wall & Other Masonry WallJunction (Figure 11)


Note: This detail was prepared based on current standard practice applicable to most masonry walls such as brick wall,
Such details may prone to exhibit hairine crack (At the RC wall & AAC wall joint). For best result, control joint
i ncorpe rati ng f lexi ble sealant is re com m en de d.

10mm to 30mm gap filled


with cement sand mortar
Fibre glass reinforcing tape
(1:7 to 1:8 mix ratio)
(150mm) bedded into skim
coat/ render/ plaster

Ir Starken AAC Block wall

Skim coating or render to


ST2 Ties, one end fixed to reinforced both sides as specified
concrete stiffener/ column and another
end embedded into adhesive at block
vertical joint

Wall Junction (Plan View)