Anda di halaman 1dari 2

SRP-6PA SERIES 6 INCH 72 CELLS

320-335W

KEY FEATURES

Bankable products

Safety for salt mist corrosion


(IEC61701, tested in TÜV SÜD)

Safety for ammonia corrosion


(IEC62716, tested in TÜV SÜD)

MANAGEMENT SYSTEM
ISO 9001: Quality management system
ISO 14001: Standard for environmental management system
Top rank in Photon yield measurement OHSAS 18001: International standard for occupational health and safety assessment
system

INSURANCE
Safety for fire risk
(Class C tested in TÜV SÜD and Rheinand)

PRODUCT CERTIFICATES
Outstanding power output capability at low irradiance

WARRANTY
100%
97.5% 97.5% Add
Triple 100% Electroluminescence (EL) tests minimize tion
al V
94.7% alue
breakage rate from
Line
91.2% ar War
90% ra nty
87.7%
3.42%
84.2%
World 1st company to pass “Thresher Test” and “On-site
4.32%
Power Measure ment Validation” certificate 80.7%
80%

0 5 10 15 20 25
YEARS Guaranteed Power

Anti-PID products, passing TÜV SÜD system voltage durability test


10
YEARS
Guarantee on product
material and workmanship
25
YEARS
linear power
output warranty

Specifications are subject to change without further notification SRP-DS-EN-2018V2.0 © Copyright 2018 Seraphim

SERAPHIM SOLAR SYSTEM CO., LTD.


www.seraphim-energy.com info@seraphim-energy.com
SRP-6PA SERIES 6 INCH 72 CELLS

Electrical Characteristics
Module Type SRP-320-6PA SRP-325-6PA SRP-330-6PA SRP-335-6PA

STC NOCT STC NOCT STC NOCT STC NOCT

Maximum Power -Pmp (W) 320 236 325 240 330 244 335 248

Open Circuit Voltage -Voc (V) 45.5 42 45.7 42.2 45.9 42.4 46.2 42.6

Short Circuit Current -Isc (A) 8.96 7.24 9.03 7.30 9.12 7.37 9.20 7.43

Maximum Power Voltage -Vmp (V) 37 34.6 37.3 34.8 37.5 35.0 37.7 35.3

Maximum Power Current -Imp (A) 8.65 6.83 8.72 6.89 8.80 6.98 8.89 7.02

Module Efficiency STC-ηm (%) 16.49 16.75 17.01 17.26


Power Tolerance(W) (0,+4.99)
Maximum System Voltage (V) 1000 (TÜV)
Maximum Series Fuse Rating (A) 15
Pmax Temperature Coefficient -0.41%/°C
Voc Temperature Coefficient -0.32 %/°C
Isc Temperature Coefficient +0.05 %/°C
Operating Temperature -40~+85 °C
Nominal Operating Cell Temperature 45±2 °C
STC: lrradiance 1000 W/m2 module temperature 25°C AM=1.5
NOCT: lrradiance 800 W/m2 ambient temperature 20°C wind speed :1m/s Power measurement tolerance: +/-3%

Curve Technical drawing

10 10 40±1
Cells temp. = 25 °C
Incident Irrad. = 1000 W/m²

Junction Box
8 8 Mounting holes
Incident Irrad. = 800 W/m²

I
SERIAL NUMBER

6 6
Incident Irrad. = 600 W/m²
Current [A]

SERIAL NUMBER
Current [A]

Label

4 Incident Irrad. = 400 W/m² 4 Incident Irrad. = 1000 W/m²

1100 ±1
Cells temp. = 10 °C
Cells temp. = 25 °C
Cells temp. = 40 °C
CELL COLOR LABEL

2 Incident Irrad. = 200 W/m² 2 Cells temp. = 55 °C


Cells temp. = 70 °C

0 0 Grounding holes
0
Ø2
0 10 20 30 40 50 0 10 20 30 40 50 2×Ø4
10±1
1956±1

1176±1
1676±1

Voltage [V] Voltage [V]


SERIAL NUMBER

negative ( - ) positive ( + )

Mechanical Specifications Connector

External Dimension 1956 x 992 x 40mm


Weight 21.5kg A A

Solar Cells Poly crystalline 156.75 x 156.75 mm (72pcs)



Glass of Both Side 3.2 mm tempered glass, low iron
Frame Anodized aluminium alloy
942±1
Junction Box IP67 992±1

Output Cables 4.0 mm2,cable length:1100 mm


35
9 70 70
.5

Connector MC4 Compatible


R4

70

Mechanical Load 5400 Pa


14

40
70

II
Packing Configuration I
2:1
5:1
Section A-A
External Dimension 1956 x 992 x 40mm 10:1

Container 20’GP 40’GP


Pieces per Pallet 27 27 * All Dimensions in mm
* The above drawing is a graphical representation of the product.
For engineering quality drawings please contact SERAPHIM.
Pallets per Container 10 22
Pieces per Container 270 594

Specifications are subject to change without further notification SRP-DS-EN-2018V2.0 © Copyright 2018 Seraphim

SERAPHIM SOLAR SYSTEM CO., LTD.


www.seraphim-energy.com info@seraphim-energy.com

Anda mungkin juga menyukai