II. High-capacity storage tank HLS


Product specification
 Upright storage tank made of steel S235JRG2 with a large surface bare-tube heat exchanger
 Enamelling in accordance with DIN 4753 Part 3 on the inside, primer applied to the outside
 Magnesium protection anode of 1¼’’ provided for completion of the
cathodic corrosion protection
 The temperature probes can be placed in variable positions due to the use of
sensor terminal blocks
 Inspection opening 180 x 110 x LK 150
 All external threads are flat sealing
 CFC free soft PU-foam insulation with a thickness of 80 mm and a PVC coating,
bottom insulation included, in accordance with DIN 4753 Part 8,
RAL colours 9006; 9010; 2002; 5015
 Compressive strength 10 bar

B Storage tank model HLS 150 HLS 200 HLS 300 HLS 400 HLS 500

Änderungen im Zuge der Weiterentwicklung vorbehalten. Für evtl. Druckfehler und Irrtümer in diesem Produktblatt übernehmen wir keine Haftung.
Capacity [litre] 150 200 300 400 500
Diameter without insulation [mm] 500 500 550 600 650
Diameter with insulation [mm] 660 660 710 760 810
Insulation [mm] 80
Height with insulation [mm] 1002 1262 1560 1790 1756
Tilted height [mm] 1000 1250 1550 1780 1760
Heating area [m2] 1,0 1,5 3,2 4,2 4,6
Water content WT [litre] 6,3 9,4 20,1 26,4 28,9
Volume flow WT [m³/h] 1,3 2,0 3,6 3,8 4,0
Pressure loss WT [mbar] 50 120 410 590 720
Perfomance index* according to DIN 4708 2,6 4,9 19 27 35

Continuous output according to


760 990 2100 2250 2400
DIN 4708 (10º/80º/45º) [l/h]

Max. T / max. P TW [°C / bar] 95 / 10


Max. T / max. P HZG** [°C / bar] 160 / 25
Cold-/Hotwater, ext. thread (KW/WW) [inches] G1 G1 G1 G1 G1
Circulation, (Z) [inches] G ¾ ext. thread G ¾ ext. thread G ¾ int. thread G ¾ int. thread G ¾ int. thread
Heat exchangers (VL/RL) [inches] G 1 ext. thread G 1 ext. thread Rp 1 int. thread Rp 1 int. thread Rp 1 int. thread
Electric heating allowed for (via the inspection flange)
Nominal width of the inspection flange (RFL) DN 110
Connections for sensors/regulators Sensor terminal block
Thermometer connection M8 thermometer optional
Dimensions
KW [mm] 110 110 115 129 130
RL [mm] 180 180 210 210 225
VL [mm] 500 500 550 600 650
Z [mm] 522 632 1000 906 1200
WW [mm] 839 1099 1393 1611 1571
Weight [kg] 74 89 170 208 235

* In order to achieve the performance index NL given here the boiler output needs to be higher than the stated continuous output.