Steel Structures-I: Assignment 2

(Unit 3 and 4: Tension and Compression Members)

1. Design a tension member subjected to an axial load of 150 KN. Use single angle and the thickness of the gusset
plate is 12mm.

2. Determine the tensile strength of an equal angle section 60mm x 60mm x 6mm, if single leg of the angle is
connected to the gusset plate by a fillet weld.

3. Select a suitable angle section to carry a factored tensile load of 150 KN. Use M20 bolts (HSFG).

4. Determine the tensile strength of a single angle section 80mm x 80mm x 6mm connected to a 8mm thick gusset
plate with four 20mm diameter bolts in a single row.

5. Design a built-up column 7.2m long and required to carry a load of 4000 KN. The column is effectively held in
position at both ends restrained in direction at one end

6. Design a laced column of length of 9m with two channels back-to-back and to carry an axial load of 1000 KN.
The column is restrained in position but not in direction at both ends

7. Design a battened column 10m long to carry a factored axial load of 1200 KN. The column is restrained in
position but not in direction at both ends. Assume the channels are placed toe-to-toe

8. Calculate the design strength of a built-up compression member consisting of ISHB 300 with a cover plate
325mm x 16mm on each flange. The length of the column is 6m. Assume the bottom of the column is fixed and the
top is pinned.

Steel Structures-I: Assignment 2


(Unit 3 and 4: Tension and Compression Members)

1. Design a tension member subjected to an axial load of 150 KN. Use single angle and the thickness of the gusset
plate is 12mm.

2. Determine the tensile strength of an equal angle section 60mm x 60mm x 6mm, if single leg of the angle is
connected to the gusset plate by a fillet weld.

3. Select a suitable angle section to carry a factored tensile load of 150 KN. Use M20 bolts (HSFG).

4. Determine the tensile strength of a single angle section 80mm x 80mm x 6mm connected to a 8mm thick gusset
plate with four 20mm diameter bolts in a single row.

5. Design a built-up column 7.2m long and required to carry a load of 4000 KN. The column is effectively held in
position at both ends restrained in direction at one end

6. Design a laced column of length of 9m with two channels back-to-back and to carry an axial load of 1000 KN.
The column is restrained in position but not in direction at both ends

7. Design a battened column 10m long to carry a factored axial load of 1200 KN. The column is restrained in
position but not in direction at both ends. Assume the channels are placed toe-to-toe

8. Calculate the design strength of a built-up compression member consisting of ISHB 300 with a cover plate
325mm x 16mm on each flange. The length of the column is 6m. Assume the bottom of the column is fixed and the
top is pinned.