This section gives basic • Flow divider/combiners For example: FDC1-10-*–66 This valve is used in place
specifications for the com- (FDC1) with flows rated will divide an incoming flow of a standard flow divider-
plete line of Vickers screw- to 568 L/min (150 of 45 L/min (12 USgpm) combiner in systems where
in cartridge flow control USgpm). equally out each port with hydraulic motors are used
valves. Its purpose is to • Posi-traction valves an accuracy of 10% each as drive wheels on each
provide a quick, convenient (FDC3) with flows rated side. With 45 L/min (12 side of the machine. The
reference tool when choos- to 567 L/min (150 USgpm) in at “3” port, flow positive traction valve acts
ing Vickers cartridge valves USgpm) out port “4” can be 22 much like a standard flow
or designing a system L/min (6 USgpm) 4,5 L/min divider-combiner as the
using these components. • Operating pressures to (1.2 USgpm) while flow at vehicle travels in a straight
350 bar (5000 psi). port “2” is 22,7 L/min (6 line. Equal amounts of flow
Valve Features and Here are some of the bene- USgpm) 4,5 L/min (1.2 go to each “C” port. As the
Benefits fits of Vickers flow USgpm). vehicle turns a corner, a
Eaton offers a complete controls: The combining accuracy is standard flow divider will
range of Vickers flow con- the same with incoming maintain equal flow to each
• All operating parts are
trols cartridge valves, with a flow at port “4” and “2” drive motor. On a turn, it is
hardened steel, ground
variety of features, including: and flow out port “3” of 45 necessary for the outer
and honed for long life
and low leakage. L/min (12 USgpm). Inlet wheel to turn faster than F
• Products in this catalog the inner wheel. A standard
have been Fatigue tested flow at port “4” will be 22
• Designed for maximum flow divider-combiner will
to one million cycles L/min (6 USgpm) 4,5 L/min
flexibility and minimal provide equal flow to each
at 132% or 10 million (1.2 USgpm). Inlet flow at
space requirements. motor causing the drive
cycles at 115% of rated port “2” will be 22 L/min (6
• All exposed cartridge sur- USgpm) 4,5 L/min (1.2 motors to skid. The positive
pressure. traction valve solves this
faces are zinc dichromate USgpm).
• Non-adjustable, pressure plated to resist corrosion. problem by allowing the
compensated, flow regu- Flow division or combining one motor to turn faster
Steel housings are avail-
lator for flows to 227 will be maintained even if than the other.
able for cartridges rated
L/min (60 USgpm). unequal loads are placed on
to 350 bar (5000 psi) This operates in a similar
ports “4” and “2”.
• Adjustable, pressure application pressures. way as a mechanical differ-
compensated, flow regu- A special feature of the ential on an automobile. In
• All aluminum manifolds
lator for flows to 114 FDC1–** is that it provides a turn, the inside drive
are gold anodized to
L/min (30 USgpm). rephase flow to either port motor is restricted and
resist corrosion.
2 or port 4 when one of the builds up pressure, while
• Fixed and adjustable pri- • Reliable, economical and two is blocked. This feature the outside drive motor is
ority bypass type flow compact. is useful in hydraulic circuits without restriction. Under
regulator for regulated that require cylinders to conditions of high differen-
• Low leakage.
flows to 114 L/min (30 move at the same time. If tial pressure, the positive
USgpm). • Variety of adjustment one cylinder bottoms out
options. traction valve passes extra
• Adjustable flow control first, the opposite cylinder is flow to the least restricted
without free reverse flow • Adjustments designed provided with “rephase” motor to prevent skidding.
check with flows rated to not to go spring solid at flow to allow the cylinder to Under straight running con-
114 L/min (30 gpm). “full in” position or to bottom and start the cylin- ditions the differential pres-
allow the adjustment to ders together for movement sure is low and equal
• Adjustable flow control in the opposite direction.
be removed when amounts of flow are provid-
with free reverse flow
backed out. ed to each drive motor.
check with flows rated to
Notable are the two styles FDC3-**
45 L/min (12 gpm).
of flow divider/combiner: The FDC3-** is a cartridge WARNING
• Needle valves with flows
type positive traction valve For pressure over
rated to 265 L/min (70 •
FDC1-** that divides and combines 210 bar (3000 psi)
USgpm).
The FDC1-** is a cartridge flow, regardless of system use steel housing.
• Velocity fuses with flows load or pressure, propor-
type hydraulic flow divider-
rated to 227 L/min (60 tionally per specified flow
combiner valve. It divides
USgpm). division.
and combines flow, regard-
less of system load or pres-
sure, proportionally per
specified flow division.
A
Flow - L/min
8
Flow - USgpm
2.0
6
1.5
4
A – 9,5 L/min (2.5 USgpm) 1.0
B
B – 1,9 L/min (0.5 USgpm) 0.5 2
C – 0,38 L/min (0.1 USgpm)
C
0
0 1000 2000 3000 4000 5000
Pressure - psi
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
1
Ø12,62 (0.497) Aluminum hous-
ings can be used
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The FR5-10-F is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure compen- stant flow from port 1 to port 2 to port 1 is at the
sated, restrictive screw-in port 2 based on 5.5 bar (80 value of the fixed orifice
flow regulator cartridge psid) regardless of pressure and is non-pressure
valve. changes downstream on compensated.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow 23 L/min (6 USgpm)
Flow regulation accuracy 0,38–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
2 0,38–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9 – 5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
1 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,12 kg (0.26 lbs.)
Sectional View Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont
A 20
(21,8 cSt oil @ 49°C)
5
Flow - USgpm
Flow - L/min
4 B 16
3 12
C
2 8
1 D 4
0
0 1000 2000 3000 4000 5000
Differential pressure - psi
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
0.875"-14 Thd.
31,7
2
(1.25)
1
Aluminum hous-
Ø15,82 (0.623) ings can be used
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The FR1-16-F is a This valve maintains a con- port 2. Reverse flow from
fixed orifice, pressure com- stant flow from port 1 to port 2 to port 1 is at the
pensated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.
2
Pressure - bar
0 70 140 210
35 140
(105 SUS oil @ 120°F)
1 A
30 120
Flow -L/min
Flow - USgpm
25 100
20 80
15 B 60
10 40
C 20
5
0 0
0 1000 2000 3000
Pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing to
108-122 Nm (80-90 ft.lbs)
1.312"-12 Thd.
44,4
(1.75) 2
1
Ø28,55 (1.124)
Description Operation
The FR1-20-F is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure compen- stant flow from port 1 to port 2 to port 1 is at the
sated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.
Pressure - bar
2 0 70 140 210
70 280
(105 SUS oil @ 120°F)
A 240
Flow - L/min
60
Flow - USgpm
1 50 200
40 160
B
30 120
20 C 80
10 40
0 0
0 1000 2000 3000
Pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
38,1 47,2 (1.87) hex
Torque cartridge in (1.50)
aluminum housing to
128-155 Nm (95-115 ft.lbs)
1.625"-12 Thd.
57,1
2
(2.25)
Ø36,47 (1.436)
Description Operation
The FR2-10-F is a limited This valve maintains a con- stream on port 2. Reverse
range adjustable*, pressure stant flow from port 1 to flow from port 2 to port 1
compensated, screw-in port 2 based on the setting is at the value of the fixed
flow regulator cartridge adjustment, regardless of orifice and is non-pressure
valve. pressure changes down compensated.
Pressure - bar
0 35 70 100 140 175 210
(105 SUS oil @ 120°F)
40
A
(21,8 cSt oil @ 49°C)
9
Flow - USgpm
Flow - L/min
30
6
B 20
2 3
10
1 0 0
0 500 1000 1500 2000 2500 3000
Pressure - psi
FR 2 – 10 (V) – * – ** – *.*– 00
1 2 3 4 5 6 7
80,0
(3.15)
53,0
25,4 (1.00) hex (2.09)
25,4 (1.00) hex
1
Ø15,82 (0.623)
Description Operation
The FR2-16 is a limited This valve maintains a con- stream on port 2. Reverse
range adjustable*, pressure stant flow from port 1 to flow from port 2 to port 1 is
compensated, screw-in port 2 based on the setting at the value of the fixed ori-
flow regulator cartridge adjustment, regardless of fice and is non-pressure
valve. pressure changes down compensated.
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,71 kg (1.57 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont
150
A
(21,8 cSt oil @ 49°C)
Flow - USgpm
30 120
Flow - L/min
90
20
B 60
10
30
C
2
0 0
0 500 1000 1500 2000 2500 3000
1 Pressure drop - psi
1 2 3 4 5 6 7
107,2 104,0
(4.22) (4.09)
1.312"-12 Thd.
44,5
2 (1.75)
1
Ø28,55 (1.124)
Description Operation
The FAR1–10 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor, screw-in cartridge valve sure changes upstream of regulated flow base within and counter- clockwise to
with free reverse flow. port 1, or downstream of the adjusting range from 1 increase the flow. This valve
port 2. 13.8 bar (200 psi) to 38 lpm (0.25 to 10 allows free reverse flow
Functional Symbol from port 2 to port 1.
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 5–350 bar (75–5000 psi) steel housing
Min. pressure differential across valve 14 bar (200 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 1–38 L/min (.25–10 USgpm)
Flow regulation accuracy 4–38 L/min (1–10 USgpm) ±10%
1 1–4 L/min (0.25–1 USgpm) ±20%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Sectional View
Reverse check crack pressure 1.7 bar (25 psi)
Leakage at shutoff position 0.4 L/min (24.4 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,02 kg (0.44 lbs.)
“K” 0,23 kg (0.51 lbs.)
“H” 0,26 kg (0.59 lbs.)
Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont
2
Typical Flow Regulation
Cartridge only
12 40
(21,8 cSt oil @ 49°C)
Pressure drop - bar
Pressure drop - psi
10
150
Flow - USgpm
Flow -L/min
8 32
8
100 6 24
4 16
4
50
2 8
1 2 3 4 5 6 7 8
Description Operation
The FAR1–12 is a two-way, This valve maintains a con- the valve to obtain pressure clockwise to decrease the
fully adjustable, pressure stant flow from port 1 to compensated control. The flow and counter- clockwise
compensated, flow regula- port 2 regardless of pres- regulated flow base within to increase the flow. This
tor, screw-in cartridge valve sure changes upstream of the adjusting range from valve allows free reverse
with free reverse flow. port 1, or downstream of 1,5 to 94,5 lpm (0.4 to 25 flow from port 2 to port 1.
port 2. 15,9 bar (230 psi) USgpm) is set by turning
Functional Symbol must be maintained across the adjusting screws
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 315 bar (4500 psi)
Min. pressure differential across valve 15,9 bar (230 psi)
Max. pressure differential across valve 329 bar (4770 psi)
1 Rated flow 1,5–94,5 L/min (.4–25 USgpm)
Flow regulation accuracy 1,5–3,8 L/min (.4–1.0 USgpm) ±20% @5000 psi
Sectional View above 3,8–68,1 L/min (above 1–18 USgpm) ±10% @3000 psi
above 68,1–94,6 L/min (above 18–25 USgpm) ±15% @3000 psi
3,8–56,8 L/min (1–15 USgpm) ±10% @5000 psi
above 56,8–89,1 L/min (above 15–23 USgpm) ±15% @5000 psi
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Reverse check crack pressure 1,7 bar (25 psi)
Leakage at shutoff position 0,5 L/min (30 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–12–2 & C–12–2U
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,43 kg (0.95 lbs.)
Seal kits 02–181304 Buna-N
2 02–181305 Viton®
Viton is a registered trademark of E.I. DuPont
12 75
(21,8 cSt oil @ 49°C)
20
Flow - USgpm
Flow - L/min
150
16 60
8
100 12 45
8 30
50 4
4 15
1 2 3 4 5 6 7 8
Description Operation
The FAR1–16 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor screw-in cartridge valve. sure changes upstream of regulated flow base within and counter- clockwise to
port 1, or downstream of the adjusting range from increase the flow. This valve
Functional Symbol port 2. 17 bar (250 psi) 3,8 to 113,6 L/min (1.0 to 30 allows free reverse flow
2 from port 2 to port 1.
200
(21,8 cSt oil @ 49°C)
Pressure drop - psi
12 120
Pressure drop - bar
30
Flow - USgpm
Flow - L/min
150 100
24 80
8
100 18 60
4 12 40
50
6 20
1 2 3 4 5 6 7 8
1 Function 6 Port size & valve bodies 7 Factory set flow rate
Description Operation
The PFR5–8 is a fixed ori- This valve maintains a con- changes downstream on the spool will shift to try
fice, priority type, pressure stant, factory-set, priority port 3. Flow in excess of and satisfy the priority flow
compensated, flow regula- flow from port 1 to port 3 the priority setting is direct- requirement, thereby clos-
tor, screw-in cartridge based on 5.5 bar (80 psid) ed to port 2. If the priority ing off flow to port 2.
valve. regardless of pressure flow at port 3 is blocked,
3 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) in steel housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated flow maximum inlet flow 15,1 L/min (4 USgpm)
maximum regulated flow 10 L/min (2.5 USgpm)
2
Internal leakage 82 cm3 /min. @ 350 bar (3000 psi) 5 in3 /min @ 5000 psi)
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
1 0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–10 L/min (1.5–2.5 USgpm) ±10% @ 350 bar (5000 psi)
Sectional View Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–8–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,07 kg (0.15 lb.)
3 Seal kits 02–173427 Buna-N
02–173434 Viton®
Viton is a registered trademark of E.I. DuPont
Pressure - bar
1
350 280 210 140 70 0 70 140 210 280 350
3.0 12
(105 SUS oil @ 120°F)
2.5 10
(21,8 cSt oil @ 49°C)
Flow - USgpm
Flow - L/min
2.0 8
1.5 6
1.0 4
0.5 2
0
0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Priority pressure
higher than priority higher than bypass
Pressure - psi
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
0.750"–16 Thd.
40,6 3
(1.60)
Aluminum hous-
1 ings can be used
Ø14,2 (0.559) • for pressures up to
210 bar (3000 psi)
Ø15,8 (0.622) Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The PFR5-10-F is a fixed This valve maintains a con- changes downstream on the spool will shift to satis-
orifice, priority type, stant, factory-set, priority port 3. Flow in excess of fy the priority flow require-
pressure compensated, flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
flow regulator screw-in based on 5.5 bar (80 psid) ed to port 2. If the priority flow to port 2.
cartridge valve. regardless of pressure flow at port 3 is blocked,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow Maximum inlet flow 60 L/min (15 USgpm)
Maximum regulated flow 23 L/min (6 USgpm)
3 Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges.
Pressure - bar
350 280 210 140 70 0 70 140 210 280 350
3 6.0 24
(105 SUS oil @ 120°F)
5.0 20
(21,8 cSt oil @ 49°C)
Flow - USgpm
Flow - L/min
4.0 16
2
3.0 12
2.0 8
1
1.0 4
0 0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Pressure - psi Priority pressure
higher than priority higher than bypass
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
0.875"-14 Thd.
46,0
(1.81) 3
1 Aluminum hous-
Ø15,82 (0.623) ings can be used
• for pressures up to
210 bar (3000 psi)
Ø17,42 (0.686) Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The PFR1-16-F is a fixed This valve maintains a con- changes downstream on the spool will shift to satis-
orifice, priority type, pres- stant, factory-set, priority port 3. Flow in excess of fy the priority flow require-
sure compensated, flow flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
regulator screw-in cartridge based on 5.5 bar (80 psid) ed to port 2. If the priority flow to port 2.
valve. regardless of pressure flow at port 3 is blocked,
30 120
Priority flow rate - L/min
(105 SUS oil @ 120°F)
A
(21,8 cSt oil @ 49°C)
25 100
20 B 80
15 60
A
10 40
B
5 20
0 0
0 500 1000 1500 2000 2500 3000
Back pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum housing to 38,1 (1.50) hex
25,4
108–122 Nm (80–90 ft.lbs) (1.00)
1.312"-12 Thd.
3
73,0
(2.87)
1
Ø26,95 (1.061)
Ø28,55 (1.124)
Description Operation
The PFR2-10 is a limited This valve maintains a con- sure changes downstream the spool will shift to satis-
range adjustable*, pressure stant, factory-set, priority on port 3. Flow in excess of fy the priority flow require-
compensated, priority type, flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
flow regulator screw-in car- based on the setting adjust- ed to port 2. If the priority flow to port 2.
tridge valve. ment, regardless of pres- flow at port 3 is blocked,
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow Maximum inlet flow 60 L/min (15 USgpm)
Maximum regulated flow 38 L/min (10 USgpm)
3
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20%
1,9–7,5 L/min (0.5–1.99 USgpm) ±15%
7,6–37,8 L/min (2.0–10.0 USgpm) ±10%
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
2 Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–10–3
Fluids All general purpose hydraulic fluids such as:
1 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,25 kg (0.54 lb.)
Sectional View Seal kits 565804 Buna-N
889599 Viton®
Viton is a registered trademark of E.I. DuPont
A
(21,8 cSt oil @ 49°C)
9
B 30
6 A
20
3
B
3
10
2
0 0
1 0 500 1000 1500 2000 2500 3000
Back pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch) "C" Adjustment
Torque cartridge in 19,0 (0.75) hex
"K"Adjustment
aluminum housing to Ø38,1 (1.50)
47–54 Nm (35–40 ft.lbs)
"S"Adjustment
4,8 (0.18) hex
80,0
(3.15)
0.875"-14 Thd.
46,0 3
(1.81)
2
1
Ø15,80 (0.622)
Ø17,40 (0.685)
Description Operation
The PFR2-16 is a limited This valve maintains a con- of pressure changes down- blocked, the spool will shift
range adjustable*, priority stant, factory-set, priority stream on port 3. Flow in to satisfy the priority flow
type, pressure compensat- flow from port 1 to port 3 excess of the priority set- requirement, thereby clos-
ed, flow regulator screw-in based on based on the set- ting is directed to port 2. If ing off flow to port 2.
cartridge valve. ting adjustment, regardless the priority flow at port 3 is
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate. Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow Maximum inlet flow 151 L/min (40 USgpm)
Maximum regulated flow 114 L/min (30 USgpm)
3 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F
2 Cavity C–16–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,43 kg (0.95 lb.)
Seal kits 565811 Buna-N
Sectional View 889610 Viton®
Viton is a registered trademark of E.I. DuPont
80
20
B
60
15
A
3
40
10
B
2
20
5
1 0
0
0 500 1000 1500 2000 2500 3000
Back pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch) "S" Adjustment
"C" Adjustment
Torque cartridge in 19,0 (0.75) hex 9,6 (0.37) hex "K" Adjustment,
aluminum housing to Ø51 (2.0)
108–122 Nm (80–90 ft.lbs)
107,2 104,0
(4.22) (4.09)
1.312"-12 Thd.
73,0 3
(2.87)
2
1
Ø26,95 (1.061)
Ø28,55 (1.124)
Description Operation
The PFR*-12 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to maximum
tems in steering and brak- ports 2 and 4 must be pro- pressure.
ing circuits. The static type vided by external relief
3 P
RATINGS AND SPECIFICATIONS
Static Signal (PFRS)
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF
Typical application pressure (all ports) 280 bar (4000 psi)
4 2
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
1 Rated inlet flow 76 L/min (20 USgpm)
LS 5
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–12–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Profile View Filtration Cleanliness code 18/16/13
Housing materials Aluminum or Steel
Weight cartridge only 0,36 kg (0.79 lb.)
Seal kit 202914-921
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.031” (not included in valve)
3 P 218 15
2 EF 145 10
Notes
1 Minimum inlet flow should 73 5
not be less than 1/4 of
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF
1 2 3 4 5 6 7
PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 055 psi (3.8 bar)
PFRD – Priority flow 078 psi (5.4 bar)
000 No Body – – –
regulator 100 psi (6.9 bar)
Dynamic signal type 10T SAE 10 SAE 4 4993511-001 4994808-001 PFRD options
12T SAE 12 SAE 4 4993511-002 4994808-002 075 psi (5.2 bar)
2 Size
04G 1/2” BSPP 1/4” BSPP 4993511-003 4994808-003 110 psi (7.6 bar) F
12 – 12 Size 145 psi (10.0 bar)
06G 3/4” BSPP 1/4” BSPP 4993511-004 4994808-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)
Dimensions
mm (inch)
Note
Standard housings include 1 1/16"-12 UN-2A
port 1, however for most
applications this port must
be blocked. 5 LS
4 CF
86.4
(3.40)
3 P Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
1 210 bar (3000 psi)
Description Operation
The PFR*-16 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
Dynamic Signal (PFRD)
port 2. The valve maintains response or circuit stability control pressure must be
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be pro- sure.
ing circuits. The static type vided by external relief
3 P RATINGS AND SPECIFICATIONS
Static Signal (PFRS) Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF Typical application pressure (all ports) 280 bar (4000 psi)
4 2 Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 150 L/min (40 USgpm)
LS 5 1
Temperature range -40° to 100° C (-40° to 210° F)
Cavity C–16–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Profile View Housing materials (standard) Steel
Weight cartridge only 0,47 kg (1.05 lbs.)
Seal kit 202915-922
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.036” (not included in valve)
5 LS
Pressure Drop Curves Flow - L/min
Cartridge only 38 75 114 151
4 CF 250
Pressure drop psi
200 14
Pressure drop bar
3 P
150 10
2 EF
100 7
1 Notes
Minimum inlet flow should
not be less than 1/4 of 50 3
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20 25 30 35 40 45
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF
1 2 3 4 5 6 7
PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 065 psi (4.5 bar)
PFRD – Priority flow 090 psi (6.2 bar)
000 No Body – – –
regulator 110 psi (7.6 bar)
Dynamic signal type 12T SAE 12 SAE 4 4993512-001 4994809-001 PFRD options
16T SAE 16 SAE 4 4993512-002 4994809-002 080 psi (5.5 bar)
2 Size
06G 3/4” BSPP 1/4” BSPP 4993512-003 4994809-003 110 psi (7.6 bar) F
16 – 16 Size 130 psi (9.0 bar)
08G 1” BSPP 1/4” BSPP 4993512-004 4994809-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)
Dimensions
mm (inch)
4 CF
96.3 (3.79)
3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1
Description Operation
The PFR*-20 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sensing flow control mode. Pump applications where is determined by assuring
priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 Meters The pressure at port 4 can
changes at 2 or 4. This (6 Feet) in length. vary by 10% when the load
1 valve is typically used with Overpressure protection for at the excess flow port 2
LS 5 open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be sure.
ing circuits. The static type provided by external relief
3 P RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Static Signal (PFRS)
Typical application pressure (all ports) 240 bar (3500 psi)
CF EF Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
4 2 Rated inlet flow 230 L/min (60 USgpm)
Temperature range -40° to 100° C (-40° to 210° F)
LS 5 1
Cavity C–20–5S
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
3 P Filtration Cleanliness code 18/16/13
Housing materials (standard) Steel
Profile View Weight cartridge only 0,86 kg (1.9 lbs.)
Seal kit 02-187543
Internal leakage 164 cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.047” (not included in valve)
4 CF 350
Pressure drop psi
300 21
3 P 250
200 14
2 EF 150
Note
Minimum inlet flow should 100 7
not be less than 1/4 of
maximum inlet flow. 50
0
Note Minimum pressure drop 0 10 20 30 40 50 60 70
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF
1 2 3 4 5 6 7
PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 080 psi (5.5 bar)
PFRD – Priority flow regulator 100 psi (6.9 bar)
000 No Body – – –
Dynamic signal type PFRD options
12T SAE 12 SAE 4 4993513-001 4994810-001 085 psi (5.9 bar)
2 Size 16T SAE 16 SAE 4 4993513-002 4994810-002 110 psi (7.6 bar)
20 – 20 Size 06G 3/4” BSPP 1/4” BSPP 4993513-003 4994810-003 7
F
Special features
3 08G 1” BSPP 1/4” BSPP 4993513-004 4994810-004
Seals 00 – None
* These model digits will not be stamped on the valve. (Only required if valve has
U– Urethane (standard)
See section J for housing details. special features, omitted
4 Body if “00”.)
O – Cartridge only
A – Aluminum
S – Steel (standard)
Dimensions
mm (inch)
3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1
Description Operation
The MRV2-10 is a 2-way, This valve will increase or rotary adjustment.
2 position, manual decrease flow by changing Recommended flow path
semi-rotary screw-in flow the variable orifice with the is 2 to 1.
restrictor valve. RATINGS AND SPECIFICATIONS
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 05 – 0-18,9 L/min (0–5 USgpm)
10 – 0-37,8 L/min (0–10 USgpm)
15 – 0-56,7 L/min (0–15 USgpm)
Internal leakage 164 cm3 /min. (10 in3/min)
maximum 210 bar (3000 psi)
Functional Symbol Temperature range -40° to 120°C (-40° to 248°F)
Manual operators B – Ball lever (friction lock)*
E – Ball lever (10 position detent)*
2 1 D – Lever (10 position detent)*
L – Lever (friction lock)*
*Light duty housings only K – Knob (non-locking)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 561810 Buna-N
Sectional View 889609 Viton®
Viton is a registered trademark of E.I. DuPont
7
A - 05
1 6
B - 10
5
C - 15
4
3
2
1
0
0 2 4 6 8 10 12 14
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7
41,0 38,1
(1.60) 58,0
(1.50) X (2.28)
X X X
42,0 42,0
(1.65) (1.65)
0.875"-14 Thd.
31,7
(1.25) 2
Ø3,45-3,50 0
(#29 or 0.136+0.002)
1 x 4,76 (0.187)
Ø15,80 (0.622) in mating housing
Description Operation
The MRV2-16 is a 2-way, 2 This valve will increase or Recommended flow path
position, manual semi- decrease flow by changing is 2 to 1.
rotary screw-in flow restric- the variable orifice with the
tor valve. rotary adjustment.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 10 – 0-37,8 L/min (0–10 USgpm) 30 – 0-113,5 L/min (0–30 USgpm)
15 – 0-56,7 L/min (0–15 USgpm) 35 – 0-132,4 L/min (0–35 USgpm)
20 – 0-75,7 L/min (0–20 USgpm) 40 – 0-151,4 L/min (0–40 USgpm)
Functional Symbol 25 – 0-94,6 L/min (0–25 USgpm) 45 – 0-170,3 L/min (0–45 USgpm)
Internal leakage 82 cm3 /min. (5 in3 /min
maximum 210 bar (3000 psi)
2 1 Temperature range -40° to 120°C (-40° to 248°F)
Manual operators D – Lever (10 position detent)
L – Lever (friction lock)
K – Knob (non-locking)
Light duty housings only
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Sectional View Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 561810 Buna-N
889609 Viton®®
Viton is a registered trademark of E.I. DuPont
Pressure Drop Curve Rated flow
Cartridge only (See model code position 6)
A - 10 E - 30
@ 5,5 bar (80 psi) B - 15 F - 35
pressure drop C - 20 G - 40
Flow - L/min (21,8 cSt oil @ 49°C) D - 25 H - 45
7
1
6
5
4
3
2
1
0 4 8 12 16 20 24 28 32 36 40 44
Flow - USgpm (105 SUS oil @ 20°F)
1 2 3 4 5 6 7
76,0
X X (3.00)
6,0
(2.40)
Description Operation
The NV1–8 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in either wise.
direction, from full flow to
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) steel housing
210 bar (3000 psi) aluminum housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow 45 L/min (12 USgpm)
Internal leakage 5 drops/min. maximum @ 350 bar (5000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 2
Cavity C–8–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,07 kg. (0.15 lbs.)
Seal Kits 02-165875 Buna–N
02-165877 Viton®
Viton is a registered trademark of E.I. DuPont
150
2
8
100
1
4
50
0 0
0 5 10 12
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum or steel housing
to 34–41 Nm (25–30 ft.lbs)
"C" Adjustment
0.750"–16 Thd.
Description Operation
The NV1–10 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in either wise.
direction, from full flow to
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Functional Symbol Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 2 Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg. (0.24 lbs.)
Seal Kits 565806 Buna–N
889627 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
5
Pressure drop - bar
70
Pressure drop - psi
60 4
50
2 3
40
30 2
1
20
1
10
0 0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
47–54 Nm (35–40 ft.lbs)
Ø42,0
(1.65)
43,0
(1.69)
0.875"-14 Thd.
31,7
(1.25) 2
1
Ø15,80 (0.622)
Description Operation
The NV1–16 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical Typical application pressure (all ports) 210 bar (3000 psi)
direction Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
of flow
Rated flow 151 L/min (40 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,34 kg. (0.76 lbs.)
Seal kits 565810 Buna–N
889609 Viton®
Viton is a registered trademark of E.I. DuPont
2
70 5
1 60
Pressure drop - bar
Pressure drop - psi
4
50
Application Note 3
40
The valve is not intended
for use at low flows, may 30
chatter below 10 L/min 2
(2.5 gpm) 20
1
10
0
0 10 20 30 40
Flow - USgpm (105 SUS oil @ 20°F)
1 2 3 4 5 6
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
108–122 Nm (80–90 ft.lbs)
Ø61,0
(2.40)
61,0
(2.40)
44,4
(1.75) 2
1
Ø28,55 (1.124)
Description Operation
The NV1–20 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Typical Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
direction
of flow Rated flow 265 L/min (70 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 Cavity C–20–2
Fluids All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum
Weight cartridge only 0,59 kg. (1.3 lbs.)
Seal kits 889615 Buna-N
889619 Viton ®
Viton is a registered trademark of E.I. DuPont
1 50
40 3
Application Note 30 2
The valve is not intended
20
for use at low flows, may
chatter below 10 L/min 1
10
(2.5 gpm)
0 0
0 10 20 30 40 50 60 70
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
128–155 Nm (95–115 ft.lbs)
Ø61,0
(2.40)
62,0
(2.44)
47,6 (1.87) hex
1.625"-12 Thd.
57,1
(2.25)
2
1
Ø36,47 (1.436)
Description Operation
The FCV7-10 is a non- This valve when applied turned counterclockwise. In above allowing flow
pressure compensated, without the free flow check the full clockwise position between port 2 and port 1,
adjustable, flow restrictor will allow flow between this valve provides tight while it allows free reverse
available with and without ports 1 and 2 through an shut-off. When applied with from port 1 to port 2.
free-flow check. increasing variable orifice the free flow check, the
when the adjustment is valve will work as stated
1 2 3 4 5 6 7
0.875"-14 Thd.
31,7
(1.25)
2
1
Ø15,82 (0.623)
Description Operation
The FCV11–12 is a direct This valve is non-pressure from full flow to tight shut
acting, adjustable needle compensated. Flow is con- off, by turning the adjust-
valve. trolled in either direction, ment feature clockwise.
Sectional View
Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60 80 100
90 6,21
A – Cartridge with C-12-2
valve body, full open 80 5,52
1 2 3 4 5 6 7 8 9
S – Steel
A – Aluminum 7 8 Valve type 9
Cavity Special features
Blank – Cavity without NV – Needle Valve 00 – None
undercut (Adjustable) (Only required if valve has
U – Cavity with undercut special features, omitted
Dimensions if “00”.)
mm (inch)
1.063"–12
Thd.
44,6
(1.80)
2
Aluminum hous-
ings can be used
• for pressures up to
1 210 bar (3000 psi)
Ø23,75 (0.935) Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The FCV6-16 is a non-pres- This valve allows flow counterclockwise. In the full
sure compensated, between ports 1 and 2 clockwise position this valve
adjustable, flow restrictor. through an increasing provides tight shut-off.
variable orifice when the
Functional Symbol adjustment is turned
80
70 5
1 60 4
50
3
40
30 2
20
1
10
0
0 10 20 30 40 50 60
Flow - USgpm (105 SUS @ 120°F)
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft.lbs)
"S" Adjustment
4,8 (0.18) hex "C" Adjustment
"K" Adjustment 19,1 (0.75) hex
Ø38,1 (1.50)
59,0
51,0 51,0 (2.32)
(2.00) (2.00)
38,1 (1.5) hex
1
Ø28,55 (1.124)
Description Operation
The VF1-10-F is a screw-in This valve is normally open setting of the valve, it clos- pressure at port 1 is
cartridge velocity fuse. from port 1 to port 2. When es. The valve returns to the reduced to less than 80 psi.
flow exceeds the open condition when the
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
Flow regulation accuracy 1,9–22,7 L/min (0.5–6.0 USgpm) ±20%
1 Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Internal leakage Port 2 to 1; <5 drops/min
maximum @ 210 bar (3000 psi)
Fusing Reverse
direction flow Temperature range -40° to 120°C (-40° to 248°F)
direction Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg (0.25 lbs.)
Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont
2
Cartridge only
A -22,8 L/min (6 USgpm)
maximum flow setting Pressure drop - bar
Port 1 to 2, fusing 0 3 7 10 14 17 20
1 direction 8 30
(105 SUS oil @ 120°F)
Port 2 to 1, reverse
(21,8 cSt oil @ 49°C)
flow down to 0 25
Flow - L/min
6
Flow - USgpm
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum housing to
47–54 Nm (35–40 ft.lbs)
0.875"-14 Thd.
31,7
(1.25)
2
1
Ø15,82 (0.623)
Description Operation
The VF1-16-F is a factory- This valve is normally open condition when the pres-
set, screw-in cartridge from port 1 to port 2. When sure at port 1 is reduced to
velocity fuse. flow exceeds the setting of less than 80 psi.
the valve, it closes. The
valve returns to the open
30
Flow - USgpm
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft. lbs)
38,1 (1.5) hex
29,0
(1.13)
1.312"-12 Thd.
44,5
(1.75)
2
1
Ø28,55 (1.124)
Description Operation
The VF1-20-F is a factory- This valve is normally open valve returns to the open
set, screw-in cartridge from port 1 to port 2. When condition when the pres-
velocity fuse. flow exceeds the setting of sure at port 1 is reduced to
the valve, it closes. The less than 80 psi.
RATINGS AND SPECIFICATIONS
Functional Symbol Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
2 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 227 L/min (60 USgpm)
Flow regulation accuracy 60–227 L/min (15–60 USgpm) ±20%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
1 Internal leakage (Port 1 to 2 closed) 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Fusing Reverse Cavity C–20–2
direction flow direction Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum
Weight cartridge only 0,82 kg. (1.80 lbs.)
Seal kits 889615 Buna–N
889619 Viton®
Viton is a registered trademark of E.I. DuPont
2
A -228 L/min (60 USgpm)
maximum flow setting
Port 1 to 2, fusing
1 direction Pressure drop - bar
Port 2 to 1, reverse 0 3 7 10 14 17 20
flow down to 0 80 300
B -114 L/min (30 USgpm)
250
(105 SUS oil @ 120°F)
A 200
The valve is not intended direction
for use in pump unloading Port 2 to 1, reverse 40 150
applications flow down to 0
C -38 L/min (10 USgpm) 100
B
maximum flow setting 20
C 50
Port 1 to 2, fusing
direction
0
Port 2 to 1, reverse 0 45 100 150 200 250 300
flow down to 0
Pressure drop - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum housing to
128–155 Nm (95–115 ft. lbs) 38,1 47,6 (1.87) hex
(1.50)
1.625"-12 Thd.
57,2
(2.25)
2
1
Ø36,47 (1.436)
Description Operation
The FDC1-10 is a pressure This valve is used in the regardless of system pres- flows from ports 2 and 4
compensated, spool type, dividing mode. It will take sure to ports 2 and 4. and combine them into port
screw-in, flow divider/com- the inlet flow (port 3) and In the combining mode this 3 according to the ratio
biner cartridge. split the flow according to valve will take the inlet specified.
the ratio specified,
3 C D
600 40
500
30
2 400
300 20
200
10
100
Note 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Port 1 unused, blocked by
blind cavity Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
8,0
(0.31) 25,4 (1.00) hex
Notes
Port 1, unused, blocked by 2
blind cavity.
Description Operation
The FDC1-16 is a pressure This valve is used in the regardless of system pres- flows from ports 2 and 4
compensated, spool type, dividing mode. It will take sure to ports 2 and 4. and combine them into port
screw-in, flow divider/com- the inlet flow (port 3) and In the combining mode this 3 according to the ratio
biner cartridge. split the flow according to valve will take the inlet specified.
the ratio specified,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Temperature range -40° to 120° C (-40° to 248° F)
2 4 Cavity C–16–4
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
3 Standard housing materials Aluminum
Weight cartridge only 0,35 kg (0.78 lbs.)
Seal Kits 889634 Buna–N
889638 Viton®
Viton is a registered trademark of E.I. DuPont
E
600 40
2 F
500
30
400
300 20
200
Note 10
100
Port 1 unused, blocked by
blind cavity 0
0 5 10 15 20 25 30 35 40 45 50
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
Dimensions
mm (inch) 13,0
(0.51) 38,1 (1.50) hex
Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft. lbs) 1.312"-12 Thd.
4
Notes
Port 1, unused, blocked by
blind cavity. 104,8
(4.12) 3
Minimum inlet flow should
not be less than 1/4 of
maximum inlet flow for
a given code. 2
Ø25,37 (0.999)
Ø26,95 (1.061)
Ø28,55 (1.124)
Description Operation
The FDC1-20 is a line This valve is used in the regardless of system pres- flows from ports 2 and 3
mounted pressure dividing mode. It will take sure to ports 2 and 4. and combine them into port
compensated, spool type, the inlet flow (port 1) and In the combining mode this 1 according to the ratio
flow divider/combiner split the flow according to valve will take the inlet specified.
valve. the ratio specified,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Fluids All general purpose hydraulic fluids such as:
2 3 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 2,6 kg. (5.75 lbs.)
1 Seal Kits 889639 Buna–N
889643 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
A
25
300 20
B
15
200
C 10
100
5
D
0
0 20 40 60 80 100
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
FDC1 – Flow divider/ CODE FLOW DIVISION% MAX. INLET FLOW 00 – None
combiner Port 4 Port 2 L/min (USgpm) (Only required if valve has
special features, omitted
2 Size 33 50 50 190,0 (50)
34 43 57 228,0 (60) if “00”.)
20 – 20 Size 36 33 67 266,0 (70)
44 50 50 266,0 (70)
3 Seals 46 40 60 304,0 (80) F
Blank– Buna-N 66 50 50 380,0 (100)
V – Viton® 88 50 50 380,0 (100)
4 Port size
178,0 (7.00)
152,4 (6.00) 12,7 (0.50)
Dimensions
mm (inch)
63,5
Torque cartridge in housing (2.50)
128–155 Nm (95–115 ft. lbs) 31,7
(1.25) 2 3
Note
Minimum inlet flow should 31,7 31,7
not be less than 1/4 of 12,7
(1.25) (1.25)
maximum inlet flow for a (0.50)
given code.
101,6 104,0
(4.00) (4.10)
76,2
(3.00)
50,8
(2.00)
44,4 44,4
1 (1.75) (1.75) Ø10,0 (0.406 thru) (3 plcs.)
76,2
(3.00)
Description Operation
The FDC3-10 is a pressure This valve is used in the In the combining mode this port 3 according to the ratio
compensated, spool type, dividing mode. It will take valve will take the inlet specified.
screw-in, posi-traction the inlet flow (port 3) and flows from ports 2 and 4
cartridge valve. split the flow to ports 2 and combine them into
and 4.
3
600 40
500
30
400
2
300 20
200
10
100
0
Note 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Port 1 unused, blocked by Inlet flow rate, port 3, - USgpm (105 SUS oil @ 120°F)
blind cavity
1 2 3 4 5 6
Dimensions
mm (inch)
Ø15,80 (0.622)
Ø17,40 (0.685)
Ø18,97 (0.747)
Description Operation
The FDC3-16 is a pressure This valve is used in the In the combining mode this
compensated, spool type, dividing mode. It will take valve will take the inlet
screw-in, posi-traction the inlet flow (port 3) and flows from ports 2 and 4
cartridge valve. split the flow to ports 2 and combine them into
and 4. port 3 according to the ratio
specified.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbol Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated inlet flow See model code, item
4 2 Temperature range -40° to 120° C (-40° to 248° F)
Cavity C–16–4 (See page 70)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
3
Standard housing materials Aluminum
Weight cartridge only 0,35 kg. (0.78 lbs.)
Seal kits 889634 Buna–N
889638 Viton®
Viton is a registered trademark of E.I. DuPont
E
Pressure drop - psi
C D
600 40
F
500
2
30
400
300 20
200
10
Note 100
1 2 3 4 5 6
FDC3 – Posi-traction valve CODE FLOW DIVISION % MAX. INLET FLOW 00 – None
Port 4 Port 2 L/min (USgpm)
(Only required if valve has
2 Size special features, omitted
16 – 16 Size 22 50 50 57,0 (15) if “00”.)
33 50 50 76,0 (20)
3 Seals 44 50 50 106,4 (28)
55 50 50 126,2 (34)
Blank– Buna-N 66 50 50 152,0 (40) F
V – Viton® 88 50 50 228,0 (60)
4 Port size
0 – Cartridge only
CODE PORT SIZE HOUSING NUMBER
Aluminum Light duty
12T SAE 12 566200
6B 3/4” BSPP 02-175468
See section J for housing details.
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
108–122 Nm (80–90 ft. lbs) 13,0
38,1 (1.50) hex
(0.51)
Ø25,37 (0.999)
Ø26,95 (1.061)
Ø28,55 (1.124)
Description Operation
The FDC3-20 is a line This valve is used in the In the combining mode this port 1 according to the ratio
mounted, pressure dividing mode. It will take valve will take the inlet specified.
compensated, spool type, the inlet flow (port 1) and flows from ports 2 and 3
posi-traction cartridge split the flow to ports and combine them into
valve. 2 and 3.
Sectional View
400
Pressure drop - psi
A C D
350 25
B
300
20
250
200 15
150
10
100
50 5
0
0 20 40 60 80 100 120 140
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
00 – None
(Only required if valve has
special features, omitted
if “00”.)
63,5
Note (2.50)
Minimum inlet flow should 31,7
not be less than 1/4 of (1.25) 2 3
maximum inlet flow for
a given code.
12,7 31,7 (1.25) 31,7 (1.25)
(0.50)
101,6
(4.00)
104,0
76,2 (4.10)
(3.00)
44,4 44,4
(1.75) (1.75) Ø10,3 (0.406 thru) (3 plcs.)
1
76,2
(3.00)