Anda di halaman 1dari 73

Flow Controls

Flow control functions for applications up to 350 bar (5000 psi)


and 570 L/min (150 gpm)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-1


Flow Controls Section F
Section contents

Typical Application Rated Flow


Model Pressure bar (psi) L/min (USgpm) Page
Flow control cartridges - Introduction, features and benefits............................................................................................F-3
Flow regulator valves, fixed, pressure compensated
FR5-8 ...........................350 (5000) ................................................................10 (2.5) ........................................................F-4
FR5-10 .........................350 (5000) ................................................................23 (6) ...........................................................F-6
FR1-16..........................210 (3000) ................................................................114 (30)........................................................F-8
FR1-20 .........................210 (3000 .................................................................227 (60) .....................................................F-10
Flow regulator valves, adjustable, pressure compensated
FR2-10 .........................210 (3000) ................................................................38 (10) .......................................................F-12
FR2-16 .........................210 (3000) ................................................................114 (30)......................................................F-14
FAR1-10 .......................350 (5000) ................................................................38 (10) .......................................................F-16
FAR1-12........................350 (5000) ................................................................95 (25) .......................................................F-18
FAR1-16........................350 (5000) ................................................................114 (30)......................................................F-20
Priority flow regulators (bypass type, fixed)
PFR5-8 .........................350 (5000) ................................................................15 (4) .........................................................F-22
PFR5-10 .......................350 (5000) ................................................................60 (15) .......................................................F-24
PFR1-16 .......................210 (3000) ................................................................151 (40) .....................................................F-26
Priority flow regulators (bypass type, adjustable)
PFR2-10 .......................210 (3000) ................................................................60 (15) .......................................................F-28
PFR2-16 .......................210 (3000) ................................................................151 (40) .....................................................F-30
Static and dynamic signal priority valves (for steering circuits)
PFR*-12 .......................280 (4000) (NEW) ....................................................76 (20) .......................................................F-32
PFR*-16 .......................280 (4000) (NEW) ....................................................150 (40) .....................................................F-34
PFR*-20 .......................280 (4000) (NEW) ....................................................230 (60) .....................................................F-36
Manual rotary flow control cartridges
MRV2-10 ......................210 (3000) ................................................................19-57 (5-15) ...............................................F-38
MRV2-16......................210 (3000) ................................................................38-170 (10-45)............................................F-40
Needle valve cartridges
NV1-8 ...........................350 (5000) ................................................................45 (12) .......................................................F-42
NV1-10 .........................210 (3000) ................................................................45 (12) .......................................................F-44
NV1-16 .........................210 (3000) ................................................................151 (40) .....................................................F-46
NV1-20 .........................210 (3000) ................................................................265 (70) .....................................................F-48
Flow control cartridges
FCV7-10 .......................210 (3000) ................................................................45 (12) .......................................................F-50
FCV11-12......................350 (5000) ................................................................114 (30)......................................................F-52
FCV6-16 .......................210 (3000) ................................................................208 (55) .....................................................F-54
Velocity fuse cartridges
VF1-10 ..........................210 (3000) ................................................................23 (6) .........................................................F-56
VF1-16..........................210 (3000) ................................................................114 (30)......................................................F-58
VF1-20..........................210 (3000) ................................................................227 (60) .....................................................F-60
Flow divider/combiner cartridges and manifold assemblies
FDC1-10 .......................210 (3000) ................................................................6-61 (1.5-16)...............................................F-62
FDC1-16 .......................210 (3000) ................................................................46-178 (12-47) ...........................................F-64
FDC1-20.......................210 (3000) ................................................................190-380 (50-100) .......................................F-66
Posi-traction cartridges and manifold assemblies
FDC3-10.......................210 (3000) ................................................................23-61 (6-16) ...............................................F-68
FDC3-16.......................210 (3000) ................................................................60-228 (15-60) ...........................................F-70
FDC3-20.......................210 (3000) ................................................................190-570 (50-150) .......................................F-72

F-2 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Flow Controls
Section introduction

This section gives basic • Flow divider/combiners For example: FDC1-10-*–66 This valve is used in place
specifications for the com- (FDC1) with flows rated will divide an incoming flow of a standard flow divider-
plete line of Vickers screw- to 568 L/min (150 of 45 L/min (12 USgpm) combiner in systems where
in cartridge flow control USgpm). equally out each port with hydraulic motors are used
valves. Its purpose is to • Posi-traction valves an accuracy of 10% each as drive wheels on each
provide a quick, convenient (FDC3) with flows rated side. With 45 L/min (12 side of the machine. The
reference tool when choos- to 567 L/min (150 USgpm) in at “3” port, flow positive traction valve acts
ing Vickers cartridge valves USgpm) out port “4” can be 22 much like a standard flow
or designing a system L/min (6 USgpm) 4,5 L/min divider-combiner as the
using these components. • Operating pressures to (1.2 USgpm) while flow at vehicle travels in a straight
350 bar (5000 psi). port “2” is 22,7 L/min (6 line. Equal amounts of flow
Valve Features and Here are some of the bene- USgpm) 4,5 L/min (1.2 go to each “C” port. As the
Benefits fits of Vickers flow USgpm). vehicle turns a corner, a
Eaton offers a complete controls: The combining accuracy is standard flow divider will
range of Vickers flow con- the same with incoming maintain equal flow to each
• All operating parts are
trols cartridge valves, with a flow at port “4” and “2” drive motor. On a turn, it is
hardened steel, ground
variety of features, including: and flow out port “3” of 45 necessary for the outer
and honed for long life
and low leakage. L/min (12 USgpm). Inlet wheel to turn faster than F
• Products in this catalog the inner wheel. A standard
have been Fatigue tested flow at port “4” will be 22
• Designed for maximum flow divider-combiner will
to one million cycles L/min (6 USgpm) 4,5 L/min
flexibility and minimal provide equal flow to each
at 132% or 10 million (1.2 USgpm). Inlet flow at
space requirements. motor causing the drive
cycles at 115% of rated port “2” will be 22 L/min (6
• All exposed cartridge sur- USgpm) 4,5 L/min (1.2 motors to skid. The positive
pressure. traction valve solves this
faces are zinc dichromate USgpm).
• Non-adjustable, pressure plated to resist corrosion. problem by allowing the
compensated, flow regu- Flow division or combining one motor to turn faster
Steel housings are avail-
lator for flows to 227 will be maintained even if than the other.
able for cartridges rated
L/min (60 USgpm). unequal loads are placed on
to 350 bar (5000 psi) This operates in a similar
ports “4” and “2”.
• Adjustable, pressure application pressures. way as a mechanical differ-
compensated, flow regu- A special feature of the ential on an automobile. In
• All aluminum manifolds
lator for flows to 114 FDC1–** is that it provides a turn, the inside drive
are gold anodized to
L/min (30 USgpm). rephase flow to either port motor is restricted and
resist corrosion.
2 or port 4 when one of the builds up pressure, while
• Fixed and adjustable pri- • Reliable, economical and two is blocked. This feature the outside drive motor is
ority bypass type flow compact. is useful in hydraulic circuits without restriction. Under
regulator for regulated that require cylinders to conditions of high differen-
• Low leakage.
flows to 114 L/min (30 move at the same time. If tial pressure, the positive
USgpm). • Variety of adjustment one cylinder bottoms out
options. traction valve passes extra
• Adjustable flow control first, the opposite cylinder is flow to the least restricted
without free reverse flow • Adjustments designed provided with “rephase” motor to prevent skidding.
check with flows rated to not to go spring solid at flow to allow the cylinder to Under straight running con-
114 L/min (30 gpm). “full in” position or to bottom and start the cylin- ditions the differential pres-
allow the adjustment to ders together for movement sure is low and equal
• Adjustable flow control in the opposite direction.
be removed when amounts of flow are provid-
with free reverse flow
backed out. ed to each drive motor.
check with flows rated to
Notable are the two styles FDC3-**
45 L/min (12 gpm).
of flow divider/combiner: The FDC3-** is a cartridge WARNING
• Needle valves with flows
type positive traction valve For pressure over
rated to 265 L/min (70 •
FDC1-** that divides and combines 210 bar (3000 psi)
USgpm).
The FDC1-** is a cartridge flow, regardless of system use steel housing.
• Velocity fuses with flows load or pressure, propor-
type hydraulic flow divider-
rated to 227 L/min (60 tionally per specified flow
combiner valve. It divides
USgpm). division.
and combines flow, regard-
less of system load or pres-
sure, proportionally per
specified flow division.

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-3


FR5-8
Flow regulator, fixed

Description Operation Operation


The FR5–8 is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure stant flow from port 1 to port 2 to port 1 is at the value
compensated, restrictive port 2 based on 5.5 bar of the fixed orifice and is non-
flow regulator screw-in (80 psid) regardless of pres- pressure compensated.
cartridge valve. sure changes downstream on

Functional Symbols RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2
Typical application pressure (all ports) 350 bar (5000 psi) steel housing
210 bar (3000 psi) aluminum housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated flow 10 L/min (2.5 USgpm)
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) 20% @ 210 bar (3000 psi)
0,4–1,9 L/min (0.1–0.49 USgpm) 40% @ 350 bar (5000 psi)
1
1,9 – 5,7 L/min (0.5–1.49 USgpm) 15%
5,7–10 L/min (1.5–2.5 USgpm) 10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Sectional View
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–8–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,05 kg (0.12 lbs.)
2
Seal kits 02–165875 Buna-N
02–165877 Viton®
Viton is a registered trademark of E.I. DuPont
1

Typical Flow Regulation


Pressure - bar
Cartridge only
0 70 140 210 280 350
3.0
10
2.5
(21,8 cSt oil @ 49°C)
(105 SUS oil @ 120°F)

A
Flow - L/min

8
Flow - USgpm

2.0

6
1.5

4
A – 9,5 L/min (2.5 USgpm) 1.0
B
B – 1,9 L/min (0.5 USgpm) 0.5 2
C – 0,38 L/min (0.1 USgpm)
C
0
0 1000 2000 3000 4000 5000
Pressure - psi

F-4 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FR5-8

FR 5 – 8 (V) – F – (*) ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate,

FR5 – Flow regulator 0 – Cartridge only nominal


(Specify in USgpm)
2 Size CODE PORT SIZE HOUSING NUMBER
Range 0,4–9,5 L/min
8 – 8 Size Aluminum Steel (0.1–2.5 USgpm)
Fatigue rated Fatigue rated
3 Seals 4T SAE 4 02–160730 02–160736 Example:
Blank – Buna-N 6T SAE 6 02–160731 02–160737 0.5– 1,9 L/min (0.5 USgpm) F
V – Viton® 8T SAE 8 02–160732 02–160738 8 Special features
4 Adjustment 2G 1/4” BSPP 02–160727 02–160733 00 – None
F – Fixed orifice 3G 3/8” BSPP 02–160728 02–160734 (Only required if valve has
See section J for housing details. special features, omitted
5 Valve housing material if “00”.)
Omit for cartridge only
S – Steel
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in steel or 8,6


aluminum housing to (0.34) 22,1 (.870) hex
34-41 Nm (25-30 ft.lbs)
0.750"-16 Thd.
27,8
(1.09)
2

1
Ø12,62 (0.497) Aluminum hous-
ings can be used
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-5


FR5-10
Flow regulator, fixed

Description Operation
The FR5-10-F is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure compen- stant flow from port 1 to port 2 to port 1 is at the
sated, restrictive screw-in port 2 based on 5.5 bar (80 value of the fixed orifice
flow regulator cartridge psid) regardless of pressure and is non-pressure
valve. changes downstream on compensated.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow 23 L/min (6 USgpm)
Flow regulation accuracy 0,38–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
2 0,38–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9 – 5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
1 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,12 kg (0.26 lbs.)
Sectional View Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 21 L/min (5.5 USgpm)


Cartridge only B – 13,3 L/min (3.5 USgpm)
C – 7,8 L/min (2.0 USgpm)
D – 0,95 L/min (0.25 USgpm)
2
Differential pressure - bar

0 70 140 210 280 350


1 6 24
(105 SUS oil @ 120°F)

A 20
(21,8 cSt oil @ 49°C)

5
Flow - USgpm

Flow - L/min

4 B 16

3 12
C
2 8

1 D 4

0
0 1000 2000 3000 4000 5000
Differential pressure - psi

F-6 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FR5-10

FR 5 – 10 (V) – F – (*) ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate

FR5 – Flow regulator 0 – Cartridge only (Specify in USgpm)


Range 0,38–22,7 L/min
2 Size CODE PORT SIZE HOUSING NUMBER
(0.1–6.0 USgpm)0 – only
10 – 10 Size Aluminum Aluminum Steel
Light duty Fatigue rated Fatigue rated 8 Special features
3 Seals 3B 3/8” BSPP 02–175462 – – 00 – None
Blank– Buna-N 2G 1/4” BSPP – 876702 02-175102 (Only required if valve has F
V – Viton® special features, omitted
3G 3/8” BSPP – 876703 02-175103 if “00”.)
4 Adjustment 6H SAE 6 – 876700 –
F – Fixed orifice 8H SAE 8 – 876701 –
6T SAE 6 566151 – 02-175100
5 Housing material
8T SAE 8 – – 02-175101
Omit for cartridge only See section J for housing details.
A – Aluminum
S – Steel

Dimensions
mm (inch)

Torque cartridge in housing 20,8 25,4 (1.00) hex


A – 47-54 Nm (35-40 ft.lbs) (0.82)
S – 68-75 Nm (50-55 ft.lbs)

0.875"-14 Thd.

31,7
2
(1.25)

1
Aluminum hous-
Ø15,82 (0.623) ings can be used
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-7


FR1-16
Flow regulator, fixed

Description Operation
The FR1-16-F is a This valve maintains a con- port 2. Reverse flow from
fixed orifice, pressure com- stant flow from port 1 to port 2 to port 1 is at the
pensated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,33 kg (0.72 lbs.)
Seal kits 565810 Buna-N
880609 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 114 L/min (30.0 USgpm)


Cartridge only B – 60 L/min (15.0 USgpm)
C – 9,5 L/min (2.5 USgpm)

2
Pressure - bar
0 70 140 210
35 140
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)

1 A
30 120
Flow -L/min
Flow - USgpm

25 100
20 80
15 B 60
10 40
C 20
5
0 0
0 1000 2000 3000
Pressure - psi

F-8 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FR1-16

FR 1 – 16 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR1 – Flow regulator 0 – Cartridge only nominal


(Specify in USgpm)
2 Size CODE PORT SIZE HOUSING NUMBER
Range 1,9–114 L/min
16 – 16 Size Aluminum Aluminum (0.5–30 USgpm)
Light duty Fatigue rated
3 Seals 6B 3/4” BSPP 02–175463 – 7 Special features
Blank– Buna-N 12T SAE 12 566149 – 00 – None F
V – Viton® 4G 1/2” BSPP – 876716 (Only required if valve has
special features, omitted
4 Adjustment 6G 3/4” BSPP – 876718 if “00”.)
F – Fixed orifice 10H SAE 10 – 876717
12H SAE 12 – 566113
See section J for housing details.

Dimensions
mm (inch)
28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing to
108-122 Nm (80-90 ft.lbs)
1.312"-12 Thd.

44,4
(1.75) 2

1
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-9


FR1-20
Flow regulator, fixed

Description Operation
The FR1-20-F is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure compen- stant flow from port 1 to port 2 to port 1 is at the
sated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 227 L/min (60 USgpm)
2 Flow regulation accuracy 3,8–18,5 L/min (1–4.9 USgpm) ±15%
19–227 L/min (5–60 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–20–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,82 kg (1.8 lbs.)
Seal kits 889615 Buna-N
889619 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 227 L/min (60.0 USgpm)


Cartridge only B – 114 L/min (30.0 USgpm)
C – 38 L/min (10.0 USgpm)

Pressure - bar
2 0 70 140 210
70 280
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)

A 240
Flow - L/min

60
Flow - USgpm

1 50 200
40 160
B
30 120
20 C 80
10 40
0 0
0 1000 2000 3000
Pressure - psi

F-10 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FR1-20

FR 1 – 20 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR1 – Flow regulator 0 – Cartridge only (Specify in USgpm)


Range 3,8 – 227 L/min
2 Size CODE PORT SIZE HOUSING NUMBER (0.1 – 60 USgpm)
20 – 20 Size Aluminum Aluminum
Light duty Fatigue rated 7 Special features
3 Seals 8B 1” BSPP 02–175464 – 00 – None
Blank– Buna-N 16T SAE 16 566409 – (Only required if valve has F
V – Viton® special features, omitted
6G 3/4” BSPP – 876732
if “00”.)
4 Adjustment 8G 1” BSPP – 876734
F – Fixed orifice 12H SAE 12 – 876733
16H SAE 16 – 876735
See section J for housing details.

Dimensions
mm (inch)
38,1 47,2 (1.87) hex
Torque cartridge in (1.50)
aluminum housing to
128-155 Nm (95-115 ft.lbs)
1.625"-12 Thd.

57,1
2
(2.25)

Ø36,47 (1.436)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-11


FR2-10
Flow regulator, adjustable

Description Operation
The FR2-10-F is a limited This valve maintains a con- stream on port 2. Reverse
range adjustable*, pressure stant flow from port 1 to flow from port 2 to port 1
compensated, screw-in port 2 based on the setting is at the value of the fixed
flow regulator cartridge adjustment, regardless of orifice and is non-pressure
valve. pressure changes down compensated.

*The flow adjustment is from the factory RATINGS AND SPECIFICATIONS


set maximum flow rate down to 50% of
that factory set flow rate. Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbol Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 38 L/min (10 USgpm)
2
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20%
1,9–7,5 L/min (0.5–1.99 USgpm) ±15%
7,6–37,8 L/min (2.0–10.0 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
1 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,22 kg (.48 lbs.)
Sectional View Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 38,0 L/min (10.0 USgpm)


Cartridge only B – 19,0 L/min (5.0 USgpm)

Pressure - bar
0 35 70 100 140 175 210
(105 SUS oil @ 120°F)

40
A
(21,8 cSt oil @ 49°C)

9
Flow - USgpm

Flow - L/min

30
6
B 20
2 3
10

1 0 0
0 500 1000 1500 2000 2500 3000
Pressure - psi

F-12 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FR2-10

FR 2 – 10 (V) – * – ** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR2 – Flow regulator 0 – Cartridge only (Specify in USgpm)


Range 0,38–22,7 L/min
2 Size CODE PORT SIZE HOUSING NUMBER (0.1–6.0 USgpm)
10 – 10 Size Aluminum Aluminum
light duty Fatigue rated 7 Special features
3 Seals 3B 3/8” BSPP 02–175462 – 00 – None
Blank– Buna-N 6T SAE 6 566151 – (Only required if valve has F
V – Viton® special features, omitted
2G 1/4” BSPP – 876702
if “00”.)
4 Adjustment 3G 3/8” BSPP – 876703
C – Cap 6H SAE 6 – 876700
F – Factory-set 8H SAE 8 – 876701
I – Internal See section J for housing details.
K – Knob
S – Screw

"S" Adjustment "K" Adjustment


Dimensions 4,8 (0.18) hex Ø38,1 (1.5)
mm (inch)
"F" Adjustment
Torque cartridge in
aluminum housing to
"C" Adjustment "I" Adjustment
47-54 Nm (35-40 ft.lbs)
19,0 (0,75) hex

80,0
(3.15)
53,0
25,4 (1.00) hex (2.09)
25,4 (1.00) hex

0.875" -14 Thd.


31,7
2 (1.25)

1
Ø15,82 (0.623)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-13


FR2-16
Flow regulator, adjustable

Description Operation
The FR2-16 is a limited This valve maintains a con- stream on port 2. Reverse
range adjustable*, pressure stant flow from port 1 to flow from port 2 to port 1 is
compensated, screw-in port 2 based on the setting at the value of the fixed ori-
flow regulator cartridge adjustment, regardless of fice and is non-pressure
valve. pressure changes down compensated.
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,71 kg (1.57 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 114 L/min (30.0


Cartridge only USgpm)
B – 38 L/min (10.0 USgpm
C – 9,5 L/min (2.5 USgpm)
Pressure drop - bar

0 35 70 100 140 175 210


40
(105 SUS oil @ 120°F)

150
A
(21,8 cSt oil @ 49°C)
Flow - USgpm

30 120
Flow - L/min

90
20
B 60
10
30
C
2
0 0
0 500 1000 1500 2000 2500 3000
1 Pressure drop - psi

F-14 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FR2-16

FR 2 – 16 (V) – * – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR2 – Flow regulator 0 – Cartridge only (Specify in USgpm)


Range 1,9–114 L/min
2 Size CODE PORT SIZE HOUSING NUMBER
(0.5–30 USgpm)
16 – 16 Size Aluminum Aluminum
Light duty Fatigue rated 7 Special features
3 Seals 6B 3/4” BSPP 02–175463 – 00 – None
Blank– Buna-N 12T SAE 12 566149 – (Only required if valve has F
V – Viton® 4G 1/2” BSPP – 876716 special features, omitted
if “00”.)
4 Adjustment 6G 3/4” BSPP – 876718
K – Knob 10H SAE 10 – 876717
S – Screw 12H SAE 12 – 876713
C – Cap See section J for housing details.

Dimensions "S" Adjustment


mm (inch) 9,6 (0.37) hex
Torque cartridge in "C" Adjustment "K" Adjustment
aluminum housing to 19,1 (0.75) hex Ø50,8 (2.00)
108-122 Nm (80-90 ft.lbs)

107,2 104,0
(4.22) (4.09)

38,1 (1.50) hex

1.312"-12 Thd.
44,5
2 (1.75)

1
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-15


FAR1-10
Flow regulator, pressure
compensated, fully
adjustable

Description Operation
The FAR1–10 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor, screw-in cartridge valve sure changes upstream of regulated flow base within and counter- clockwise to
with free reverse flow. port 1, or downstream of the adjusting range from 1 increase the flow. This valve
port 2. 13.8 bar (200 psi) to 38 lpm (0.25 to 10 allows free reverse flow
Functional Symbol from port 2 to port 1.
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 5–350 bar (75–5000 psi) steel housing
Min. pressure differential across valve 14 bar (200 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 1–38 L/min (.25–10 USgpm)
Flow regulation accuracy 4–38 L/min (1–10 USgpm) ±10%
1 1–4 L/min (0.25–1 USgpm) ±20%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Sectional View
Reverse check crack pressure 1.7 bar (25 psi)
Leakage at shutoff position 0.4 L/min (24.4 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,02 kg (0.44 lbs.)
“K” 0,23 kg (0.51 lbs.)
“H” 0,26 kg (0.59 lbs.)
Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

2
Typical Flow Regulation
Cartridge only

PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION


Flow - L/min (21,8 cSt oil @ 49ºC) Pressure differential across valve in bar
8 16 24 32 40 70 140 210 280 350
200 12
(105 SUS oil @ 120°F)

12 40
(21,8 cSt oil @ 49°C)
Pressure drop - bar
Pressure drop - psi

10
150
Flow - USgpm

Flow -L/min

8 32
8
100 6 24

4 16
4
50
2 8

0 2 4 6 8 10 12 0 1000 2000 3000 4000 5000


Flow - USgpm (105 SUS oil @ 120°F) Pressure differential across valve in psi

F-16 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FAR1-10

FAR1 – 10 (V) – * – * – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate,

FAR1 – Fully adjustable, 0 – Cartridge only Blank – Normal factory


pressure compensated flow setting at 5 USgpm
regulator with reverse flow CODE PORT SIZE HOUSING NUMBER User requested setting
check Aluminum Aluminum Steel within .25–10 US gpm
Light duty Fatigue rated Fatigue rated (1-–38 L/min.)
2 Size 3B 3/8” BSPP 02–175462 – – 8 Special features
10 – 10 Size
2G 1/4” BSPP – 876702 02-175102 F
00 – None
3 Seals 3G 3/8” BSPP – 876703 02-175103 (Only required if valve has
Blank– Buna-N 6H SAE 6 – 876700 – special features, omitted
V – Viton® 8H SAE 8 – 876701 – if “00”.)

4 6T SAE 6 566151 – 02-175100


Adjustment
8T SAE 8 – – 02-175101
S – Screw with locknut
K – Handknob with locknut See section J for housing details.
H – Calibrated handknob with
NOTE:
locknut
To reset scale and knob to an
5 Valve housing material optimum viewing position:

Omit for cartridge only 1. Loosen the set screw


S – Steel 2. Rotate zero point on scale to a desired
A – Aluminum orientation.
3. Align mark on knob with zero on scale.
38,1 4. Tighten the set screw firmly.
"H" adjustment (1.50)
"K" adjustment To change the setting:
30,5
Dimensions "S" Ø38,1 (1.20) 1. Loosen the set screw
mm (inch) 61,1
adjustment (1.50) 2. Loosen jamnut while holding the knob
(2.40) steady, or move the knob along the axis
Torque cartridge 4,75 (0.19) hex max. slightly.
in housing 3. Turn adjusting screw (jamnut and knob
A – 47–54 Nm will turn at the same time).
(35–40 ft.lbs) 4. At the new adjusting screw position,
S – 68–75 Nm 56,9 tighten jamnut firmly while holding the
72,4
(50–55 ft.lbs) (2.24)
(2.85) knob steady, or move the knob along
25,4 axis slightly.
(1.00)
“K” adjustment 5. Tighten the set screw firmly.
hex
kit – 565585
Aluminum hous-
ings can be used
31,8 76,5
• for pressures up to
0.875"–14 2 (1.25) (3.01) 210 bar (3000 psi)
Thd. max. Steel housings must be used
for operating pressures above
1 210 bar (3000 psi)
Ø15,8 (0.62)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-17


FAR1-12
Flow regulator, pressure
compensated, fully
adjustable

Description Operation
The FAR1–12 is a two-way, This valve maintains a con- the valve to obtain pressure clockwise to decrease the
fully adjustable, pressure stant flow from port 1 to compensated control. The flow and counter- clockwise
compensated, flow regula- port 2 regardless of pres- regulated flow base within to increase the flow. This
tor, screw-in cartridge valve sure changes upstream of the adjusting range from valve allows free reverse
with free reverse flow. port 1, or downstream of 1,5 to 94,5 lpm (0.4 to 25 flow from port 2 to port 1.
port 2. 15,9 bar (230 psi) USgpm) is set by turning
Functional Symbol must be maintained across the adjusting screws
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 315 bar (4500 psi)
Min. pressure differential across valve 15,9 bar (230 psi)
Max. pressure differential across valve 329 bar (4770 psi)
1 Rated flow 1,5–94,5 L/min (.4–25 USgpm)
Flow regulation accuracy 1,5–3,8 L/min (.4–1.0 USgpm) ±20% @5000 psi
Sectional View above 3,8–68,1 L/min (above 1–18 USgpm) ±10% @3000 psi
above 68,1–94,6 L/min (above 18–25 USgpm) ±15% @3000 psi
3,8–56,8 L/min (1–15 USgpm) ±10% @5000 psi
above 56,8–89,1 L/min (above 15–23 USgpm) ±15% @5000 psi
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Reverse check crack pressure 1,7 bar (25 psi)
Leakage at shutoff position 0,5 L/min (30 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–12–2 & C–12–2U
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,43 kg (0.95 lbs.)
Seal kits 02–181304 Buna-N
2 02–181305 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation


Cartridge only
1
PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION
Flow - L/min (21,8 cSt oil @ 49°C) Pressure differential across valve in bar
15 30 45 60 75 90 70 140 210 280 350
200 90
24
(105 SUS oil @ 120°F)
Pressure drop - bar
Pressure drop - psi

12 75
(21,8 cSt oil @ 49°C)

20
Flow - USgpm

Flow - L/min

150
16 60
8
100 12 45

8 30
50 4
4 15

0 4 8 12 16 20 24 0 1000 2000 3000 4000 5000


Flow - USgpm (105 SUS oil @ 120°F) Pressure differential across valve in psi

F-18 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FAR1-12

FAR1 – 12 (V) – * – * – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size

FAR1 – Fully adjustable, 0 – Cartridge only


pressure compensated flow
regulator with reverse flow CODE PORT SIZE HOUSING NUMBER
check C-12-2U C-12-2 C-12-2U C-12-2
Aluminum Aluminum Steel Steel
2 Size Fatigue rated Fatigue rated Fatigue rated Fatigue rated
12 – 12 Size 10T(U) SAE 10 02–160641 02-160640 02-169817 02-169744 F
3
12T(U) SAE 12 02–160645 02-160644 02-169790 02-169782
Seals
4G(U) 1/2” BSPP 02–161116 02-161118 02-172512 02-172062
Blank– Buna-N
V – Viton® 6G(U) 3/4” BSPP 02–161115 02-161117 02-162922 02-169665
See section J for housing details.
4 Adjustment
S – Screw with locknut
K – Handknob with locknut 7 8
Factory set flow rate, Special features
H – Calibrated handknob with
locknut Blank – Normal factory 00 – None
setting at 10 USgpm (Only required if valve has
5 Valve housing material User requested setting special features, omitted NOTE:
Within .04–25 US gpm if “00”.)
Omit for cartridge only To reset scale and knob to an
(1,5-–94,6 L/min.) up to
S – Steel optimum viewing position:
210 bar (3000 psi)
A – Aluminum 1. Loosen the set screw.
Within 0.4-23 USgpm
(1,5-87,1 L/min.) up to 2. Rotate zero point on scale to a desired
350bar (5000 psi) orientation.
3. Align mark on knob with zero on scale.
38,1
"H" adjustment (1.50) 4. Tighten the set screw firmly.
"K" adjustment
30,5 To change the setting:
"S" Ø38,1 (1.20) 1. Loosen the set screw.
73,1
Dimensions adjustment (2.88) (1.50) 2. Loosen jamnut while holding the knob
mm (inch) 4,75 (0.19) hex max. steady, or move the knob along the axis
slightly.
Torque cartridge
3. Turn adjusting screw (jamnut and knob
in housing will turn at the same time).
A – 81–95 Nm
(60–70 ft.lbs) 67,2 4. At the new adjusting screw position,
(2.65) 82,6 tighten jamnut firmly while holding the
S – 102–115 Nm 31,7 (3.25) knob steady, or move the knob along
(75–85 ft.lbs) (1.25) axis slightly.
hex
5. Tighten the set screw firmly.
“K” adjustment
kit – 565585 Aluminum hous-
ings can be used
• for pressures up to
44,7 88,4 210 bar (3000 psi)
1.06"–12 2 (1.76) (3.48) Steel housings must be used
Thd. max. for operating pressures above
210 bar (3000 psi)
1
Ø23,7 (0.94)
EATON Vickers
Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-19
FAR1-16
Flow regulator, pressure
compensated, fully
adjustable

Description Operation
The FAR1–16 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor screw-in cartridge valve. sure changes upstream of regulated flow base within and counter- clockwise to
port 1, or downstream of the adjusting range from increase the flow. This valve
Functional Symbol port 2. 17 bar (250 psi) 3,8 to 113,6 L/min (1.0 to 30 allows free reverse flow
2 from port 2 to port 1.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
1 Min. pressure differential across valve 17 bar (250 psi)
Max. pressure differential across valve 328 bar (4750 psi)
Sectional View Rated flow 3,8–113,6 L/min (1–30 USgpm)
Flow regulation accuracy 3,8–15,1 L/min (1.0–4.0 USgpm) ±30% @5000 psi
above 15,1–30,3 L/min (above 4.0–8.0 USgpm) ±20% @5000 psi
above 30,3–113,6 L/min (above 8.0–30.0 USgpm) ±10% @5000 psi
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Reverse check crack pressure 1,7 bar (25 psi)
Leakage at shutoff position 0,55 L/min (33.5 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,67 kg (1.48 lbs.)
“K” 0,70 kg (1.55 lbs.)
2 “H” 0,74 kg (1.62 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Viton is a registered trademark of E.I. DuPont

1 Typical Flow Regulation


Cartridge only

PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION


Flow - L/min (21,8 cSt oil @ 49°C) Pressure differential across valve in bar
20 40 60 80 100 120 100 240 300 350
36
(105 SUS oil @ 120°F)

200
(21,8 cSt oil @ 49°C)
Pressure drop - psi

12 120
Pressure drop - bar

30
Flow - USgpm

Flow - L/min

150 100
24 80
8
100 18 60
4 12 40
50
6 20

0 6 12 18 24 30 36 1000 2000 3000 4000 5000


Flow - USgpm (105 SUS oil @ 120°F) Pressure differential across valve in psi

F-20 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FAR1-16

FAR1 – 16 (V) – * – * – *** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size & valve bodies 7 Factory set flow rate

FAR1 – Fully adjustable, 0 – Cartridge only Blank – Normal factory


pressure compensated flow CODE PORT SIZE HOUSING NUMBER setting at 15 USgpm
regulator with reverse flow User requested setting
Aluminum Aluminum Steel
check Light duty Fatigue rated Fatigue rated
Within 1–30 USgpm
(3,8-–113,6 L/min.) Port
2 Size 4G 1/2” BSPP – 876716 02-175106 bodies
16 – 16 Size 6B 3/4” BSPP 02-175463 – –
8
F
Special features
6G 3/4” BSPP – 876718 02-175107
3 Seals 00 – None
10T SAE 10 – – –
Blank– Buna-N (Only required if valve has
V – Viton® 10H SAE 10 – 876717 02-175104 special features, omitted
12T SAE 12 566149 – – if “00”.)
4 Adjustment
12H SAE 12 – 566113 02-175105
S – Screw with locknut See section J for housing details.
K – Handknob with locknut
H – Calibrated handknob with
NOTE:
locknut
To reset scale and knob to an
5 Valve housing material optimum viewing position:

Omit for cartridge only 1. Loosen the set screw.


S – Steel 2. Rotate zero point on scale to a desired
A – Aluminum orientation.
"H"Adjustment 38,1 3. Align mark on knob with zero on scale.
"K" Adjustment 4. Tighten the set screw firmly.
30,5 (1.50)
"S" Adjustment 82,1 Ø38,1
(3.40) max. (1.50)
To change the setting:
4,75 (0.19) hex (1.20)
79,1 1. Loosen the set screw.
(3.11) 2. Loosen jamnut while holding the knob
Dimensions steady, or move the knob along the axis
mm (inch) slightly.
38,1 94,5 3. Turn adjusting screw (jamnut and knob
Torque cartridge (3.72)
(1.50) will turn at the same time).
in housing hex
A – 108–122 Nm 4. At the new adjusting screw position,
(80–90 ft.lbs) tighten jamnut firmly while holding the
79,1
knob steady, or move the knob along
S – 136–149 Nm (3.11)
axis slightly.
(100–110 ft.lbs)
5. Tighten the set screw firmly.
“K” adjustment kit – 02-185169
101,9
46,4 (4.01) Aluminum hous-
(1.83) max. ings can be used
1.312"–12 Thd.
• for pressures up to
28,5 210 bar (3000 psi)
(1.12) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-21


PFR5-8
Priority flow regulator, fixed

Description Operation
The PFR5–8 is a fixed ori- This valve maintains a con- changes downstream on the spool will shift to try
fice, priority type, pressure stant, factory-set, priority port 3. Flow in excess of and satisfy the priority flow
compensated, flow regula- flow from port 1 to port 3 the priority setting is direct- requirement, thereby clos-
tor, screw-in cartridge based on 5.5 bar (80 psid) ed to port 2. If the priority ing off flow to port 2.
valve. regardless of pressure flow at port 3 is blocked,

Functional Symbol RATINGS AND SPECIFICATIONS

3 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) in steel housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated flow maximum inlet flow 15,1 L/min (4 USgpm)
maximum regulated flow 10 L/min (2.5 USgpm)
2
Internal leakage 82 cm3 /min. @ 350 bar (3000 psi) 5 in3 /min @ 5000 psi)
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
1 0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–10 L/min (1.5–2.5 USgpm) ±10% @ 350 bar (5000 psi)
Sectional View Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–8–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,07 kg (0.15 lb.)
3 Seal kits 02–173427 Buna-N
02–173434 Viton®
Viton is a registered trademark of E.I. DuPont

2 Typical Flow Regulation


Cartridge only

Pressure - bar
1
350 280 210 140 70 0 70 140 210 280 350
3.0 12
(105 SUS oil @ 120°F)

2.5 10
(21,8 cSt oil @ 49°C)
Flow - USgpm

Flow - L/min

2.0 8

1.5 6

1.0 4

0.5 2

0
0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Priority pressure
higher than priority higher than bypass
Pressure - psi

F-22 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFR5-8

PFR5 – 8 (V) – F – (*) – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate,

PFR5 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


CODE PORT SIZE HOUSING NUMBER
Range 0,4–9,5 L/min
2 Size (0.1–2.5 USgpm)
Aluminum Steel Example:
8 – 8 Size Fatigue rated Fatigue rated
0.5–1,9 L/min (0.5 USgpm)
3 Seals 4T SAE 4 02–160741 02-160745
8 Special features
Blank– Buna-N 6T SAE 6 02–160742 02-160746 F
V – Viton® 2G 1/4” BSPP 02–160739 02-160743 00 – None
(Only required if valve has
3G 3/8” BSPP 02–160740 02-160744
4 Adjustment special features, omitted
See section J for housing details. if “00”.)
F – Fixed orifice
5 Valve housing material

Omit for cartridge only


S – Steel
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in steel


or aluminum housing to
34–41 Nm (25–30 ft.lbs) 8,5
(0.33) 22,1 (.870) hex

0.750"–16 Thd.

40,6 3
(1.60)

Aluminum hous-
1 ings can be used
Ø14,2 (0.559) • for pressures up to
210 bar (3000 psi)
Ø15,8 (0.622) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-23


PFR5-10
Priority flow regulator, fixed

Description Operation
The PFR5-10-F is a fixed This valve maintains a con- changes downstream on the spool will shift to satis-
orifice, priority type, stant, factory-set, priority port 3. Flow in excess of fy the priority flow require-
pressure compensated, flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
flow regulator screw-in based on 5.5 bar (80 psid) ed to port 2. If the priority flow to port 2.
cartridge valve. regardless of pressure flow at port 3 is blocked,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow Maximum inlet flow 60 L/min (15 USgpm)
Maximum regulated flow 23 L/min (6 USgpm)
3 Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges.

2 Temperature range -40° to 120°C (-40° to 248°F)


Cavity C–10–3
1 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18 /16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,13 kg (0.28 lb.)
Sectional View Seal kits 565804 Buna-N
889599 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation


Cartridge only

Pressure - bar
350 280 210 140 70 0 70 140 210 280 350
3 6.0 24
(105 SUS oil @ 120°F)

5.0 20
(21,8 cSt oil @ 49°C)
Flow - USgpm

Flow - L/min

4.0 16
2
3.0 12

2.0 8
1
1.0 4

0 0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Pressure - psi Priority pressure
higher than priority higher than bypass

F-24 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFR5-10

PFR5 – 10 (V) – F – * – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate

PFR5 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


CODE PORT SIZE HOUSING NUMBER
Range 0,38–22,7 L/min
2 Size (0.1–6.0 USgpm)
Aluminum Aluminum Steel
10 – 10 Size Light duty Fatigue rated 8 Special features
3 Seals 2G 1/4” BSPP – 876705 02-175127 00 – None
Blank– Buna-N 3B 3/8” BSPP 02–173358 – – (Only required if valve has F
V – Viton® 3G 3/8” BSPP – 876714 02-175128 special features, omitted
if “00”.)
4 6T SAE 6 566162 – –
Adjustment
F – Fixed orifice 6H SAE 6 – 876704 02-175124
8H SAE 8 – 876711 –
5 Valve housing material 8T SAE 8 – 02-175125 –
Omit for cartridge only See section J for housing details.
S – Steel
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in housing


A – 47–54 Nm (35–40 ft.lbs) 25,4 (1.0) hex
20,8
S – 68–75 Nm (50–55 ft.lbs)
(0.82)

0.875"-14 Thd.
46,0
(1.81) 3

1 Aluminum hous-
Ø15,82 (0.623) ings can be used
• for pressures up to
210 bar (3000 psi)
Ø17,42 (0.686) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-25


PFR1-16
Priority flow regulator, fixed

Description Operation
The PFR1-16-F is a fixed This valve maintains a con- changes downstream on the spool will shift to satis-
orifice, priority type, pres- stant, factory-set, priority port 3. Flow in excess of fy the priority flow require-
sure compensated, flow flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
regulator screw-in cartridge based on 5.5 bar (80 psid) ed to port 2. If the priority flow to port 2.
valve. regardless of pressure flow at port 3 is blocked,

Functional Symbol RATINGS AND SPECIFICATIONS


3 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow Maximum inlet flow 151 L/min (40 USgpm)
Maximum regulated flow 114 L/min (30 USgpm)
2
Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
1 Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Cavity C–16–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,38 kg (0.84 lb.)
Seal kits 565811 Buna-N
889610 Viton®
Viton is a registered trademark of E.I. DuPont

3 Typical Flow Regulation


Cartridge only
A – Port 3, priority (regulated
2 outlet) pressurized.
B – Port 2, (bypass outlet)
pressurized.
1
Back pressure - bar
0 35 70 100 140 175 210
Priority flow rate - USgpm

30 120
Priority flow rate - L/min
(105 SUS oil @ 120°F)

A
(21,8 cSt oil @ 49°C)

25 100
20 B 80
15 60
A
10 40
B
5 20
0 0
0 500 1000 1500 2000 2500 3000
Back pressure - psi

F-26 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFR1-16

PFR1 – 16 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

PFR1 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


Range 1,9–114 L/min
2 CODE PORT SIZE HOUSING NUMBER
Size (0.5–30 USgpm)
16 – 16 Size Aluminum Aluminum
Light duty Fatigue rated 7 Special features
3 Seals 12T SAE 12 566152 – 00 – None
Blank– Buna-N 6B 3/4” BSPP 02–175465 – (Only required if valve has F
V – Viton® 10H SAE 10 – 876721 special features, omitted
if “00”.)
4 Adjustment 12H SAE 12 – 876723
F – Fixed orifice 4G 1/2” BSPP – 876720
6G 3/4” BSPP – 876722
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing to 38,1 (1.50) hex
25,4
108–122 Nm (80–90 ft.lbs) (1.00)

1.312"-12 Thd.

3
73,0
(2.87)

1
Ø26,95 (1.061)

Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-27


PFR2-10
Priority flow regulator,
adjustable

Description Operation
The PFR2-10 is a limited This valve maintains a con- sure changes downstream the spool will shift to satis-
range adjustable*, pressure stant, factory-set, priority on port 3. Flow in excess of fy the priority flow require-
compensated, priority type, flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
flow regulator screw-in car- based on the setting adjust- ed to port 2. If the priority flow to port 2.
tridge valve. ment, regardless of pres- flow at port 3 is blocked,
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow Maximum inlet flow 60 L/min (15 USgpm)
Maximum regulated flow 38 L/min (10 USgpm)
3
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20%
1,9–7,5 L/min (0.5–1.99 USgpm) ±15%
7,6–37,8 L/min (2.0–10.0 USgpm) ±10%
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
2 Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–10–3
Fluids All general purpose hydraulic fluids such as:
1 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,25 kg (0.54 lb.)
Sectional View Seal kits 565804 Buna-N
889599 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A - Port 3, priority


Cartridge only (regulated)
outlet pressurized
B - Port 2, bypass outlet
pressurized
Priority (regulated) flow rate - USgpm

Back pressure - bar


Priority (regulated) flow rate - L/min

0 35 70 100 140 175 210


40
(105 SUS oil @ 120°F)

A
(21,8 cSt oil @ 49°C)

9
B 30
6 A
20
3
B
3
10
2
0 0
1 0 500 1000 1500 2000 2500 3000
Back pressure - psi

F-28 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFR2-10

PFR2 – 10 (V) – * – ** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

PFR2 – Priority flow regulator 0 – Cartridge only nominal


(Specify in USgpm) Range
2 CODE PORT SIZE HOUSING NUMBER
Size 0,38–37,8 L/min (0.1–10.0
Aluminum Aluminum USgpm)
10 – 10 Size
Light duty Fatigue rated
3 Seals 3B 3/8” BSPP 02–173358 – 7 Special features
Blank– Buna-N 6T SAE 6 566162 – 00 – None F
V – Viton® 2G 1/4” BSPP – 876705 (Only required if valve has
special features, omitted
4 3G 3/8” BSPP – 876714 if “00”.)
Adjustment
C – Cap 6H SAE 6 – 876704
K – Knob 8H SAE 8 – 876711
S – Screw See section J for housing details.

Dimensions
mm (inch) "C" Adjustment
Torque cartridge in 19,0 (0.75) hex
"K"Adjustment
aluminum housing to Ø38,1 (1.50)
47–54 Nm (35–40 ft.lbs)

"S"Adjustment
4,8 (0.18) hex
80,0
(3.15)

25,4 (1.0) hex

0.875"-14 Thd.

46,0 3
(1.81)
2

1
Ø15,80 (0.622)
Ø17,40 (0.685)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-29


PFR2-16
Priority flow regulator,
adjustable

Description Operation
The PFR2-16 is a limited This valve maintains a con- of pressure changes down- blocked, the spool will shift
range adjustable*, priority stant, factory-set, priority stream on port 3. Flow in to satisfy the priority flow
type, pressure compensat- flow from port 1 to port 3 excess of the priority set- requirement, thereby clos-
ed, flow regulator screw-in based on based on the set- ting is directed to port 2. If ing off flow to port 2.
cartridge valve. ting adjustment, regardless the priority flow at port 3 is
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate. Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow Maximum inlet flow 151 L/min (40 USgpm)
Maximum regulated flow 114 L/min (30 USgpm)
3 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F
2 Cavity C–16–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,43 kg (0.95 lb.)
Seal kits 565811 Buna-N
Sectional View 889610 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – Port 3, priority


Cartridge only (regulated) outlet
pressurized
B – Port 2, bypass outlet
pressurized

Back pressure - bar


Priority (regulated) flow rate - USgpm

Priority (regulated) flow rate - L/min

0 35 75 100 140 175 210


100
25
A
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)

80
20
B
60
15
A
3
40
10
B
2
20
5

1 0
0
0 500 1000 1500 2000 2500 3000
Back pressure - psi

F-30 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFR2-16

PFR2 – 16 (V) – * – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

PFR2 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


Range 1,9–114 L/min
2 CODE PORT SIZE HOUSING NUMBER
Size (0.5–30 USgpm)
Aluminum Aluminum
16 – 16 Size
Light duty Fatigue rated 7 Special features
3 Seals 12T SAE 12 566152 – 00 – None
Blank– Buna-N 6B 3/4” BSPP 02-175465 – (Only required if valve has F
V – Viton® 10H SAE 10 – 876721 special features, omitted
if “00”.)
4 12H SAE 12 – 876723
Adjustment
C – Cap 4G 1/2” BSPP – 876720
K – Knob 6G 3/4” BSPP – 876722
S – Screw See section J for housing details.

Dimensions
mm (inch) "S" Adjustment
"C" Adjustment
Torque cartridge in 19,0 (0.75) hex 9,6 (0.37) hex "K" Adjustment,
aluminum housing to Ø51 (2.0)
108–122 Nm (80–90 ft.lbs)

107,2 104,0
(4.22) (4.09)

38,1 (1.50) hex

1.312"-12 Thd.

73,0 3
(2.87)
2

1
Ø26,95 (1.061)

Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-31


PFRD/S-12
Priority flow regulator valve

Description Operation
The PFR*-12 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to maximum
tems in steering and brak- ports 2 and 4 must be pro- pressure.
ing circuits. The static type vided by external relief
3 P
RATINGS AND SPECIFICATIONS
Static Signal (PFRS)
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF
Typical application pressure (all ports) 280 bar (4000 psi)
4 2
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
1 Rated inlet flow 76 L/min (20 USgpm)
LS 5
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–12–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Profile View Filtration Cleanliness code 18/16/13
Housing materials Aluminum or Steel
Weight cartridge only 0,36 kg (0.79 lb.)
Seal kit 202914-921
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.031” (not included in valve)

5 LS Pressure Drop Curves


Flow - L/min
Cartridge only 10 20 30 40 50 60 70 80 90
4 CF 290 20
Pressure drop bar
Pressure drop psi

3 P 218 15

2 EF 145 10

Notes
1 Minimum inlet flow should 73 5
not be less than 1/4 of
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF

F-32 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFRS/D-12

PFR* 12 U * *** *** 00

1 2 3 4 5 6 7

1 Function 5 Ports* 6 Control Pressure

PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 055 psi (3.8 bar)
PFRD – Priority flow 078 psi (5.4 bar)
000 No Body – – –
regulator 100 psi (6.9 bar)
Dynamic signal type 10T SAE 10 SAE 4 4993511-001 4994808-001 PFRD options
12T SAE 12 SAE 4 4993511-002 4994808-002 075 psi (5.2 bar)
2 Size
04G 1/2” BSPP 1/4” BSPP 4993511-003 4994808-003 110 psi (7.6 bar) F
12 – 12 Size 145 psi (10.0 bar)
06G 3/4” BSPP 1/4” BSPP 4993511-004 4994808-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)

Dimensions
mm (inch)

Torque cartridge in housing


A – 81-95 Nm (60–70 ft.lbs)
S – 102–115 Nm (75–85 ft.lbs) 1 1/4" HEX
33.3
(1.31)

Note
Standard housings include 1 1/16"-12 UN-2A
port 1, however for most
applications this port must
be blocked. 5 LS

4 CF
86.4
(3.40)

3 P Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
1 210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-33


PFRD/S-16
Priority flow regulator valve

Description Operation
The PFR*-16 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
Dynamic Signal (PFRD)
port 2. The valve maintains response or circuit stability control pressure must be
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be pro- sure.
ing circuits. The static type vided by external relief
3 P RATINGS AND SPECIFICATIONS
Static Signal (PFRS) Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF Typical application pressure (all ports) 280 bar (4000 psi)
4 2 Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 150 L/min (40 USgpm)
LS 5 1
Temperature range -40° to 100° C (-40° to 210° F)
Cavity C–16–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Profile View Housing materials (standard) Steel
Weight cartridge only 0,47 kg (1.05 lbs.)
Seal kit 202915-922
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.036” (not included in valve)
5 LS
Pressure Drop Curves Flow - L/min
Cartridge only 38 75 114 151
4 CF 250
Pressure drop psi

200 14
Pressure drop bar

3 P

150 10
2 EF

100 7
1 Notes
Minimum inlet flow should
not be less than 1/4 of 50 3
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20 25 30 35 40 45
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF

F-34 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFRS/D-16

PFR* 16 U * *** *** 00

1 2 3 4 5 6 7

1 Function 5 Ports* 6 Control Pressure

PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 065 psi (4.5 bar)
PFRD – Priority flow 090 psi (6.2 bar)
000 No Body – – –
regulator 110 psi (7.6 bar)
Dynamic signal type 12T SAE 12 SAE 4 4993512-001 4994809-001 PFRD options
16T SAE 16 SAE 4 4993512-002 4994809-002 080 psi (5.5 bar)
2 Size
06G 3/4” BSPP 1/4” BSPP 4993512-003 4994809-003 110 psi (7.6 bar) F
16 – 16 Size 130 psi (9.0 bar)
08G 1” BSPP 1/4” BSPP 4993512-004 4994809-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)

Dimensions
mm (inch)

Torque cartridge in housing


A – 108-122 Nm (80-90 ft. lbs)
S – 136–149 Nm (100–110 ft. 17.8 (.70) 1.50" HEX
lbs)
Note
1 5/16"-2 UN-2A
Standard housings include
port 1, however for most
applications this port must 5 LS
be blocked.

4 CF

96.3 (3.79)

3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-35


PFRD/S-20
Priority flow regulator valve

Description Operation
The PFR*-20 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sensing flow control mode. Pump applications where is determined by assuring
priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 Meters The pressure at port 4 can
changes at 2 or 4. This (6 Feet) in length. vary by 10% when the load
1 valve is typically used with Overpressure protection for at the excess flow port 2
LS 5 open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be sure.
ing circuits. The static type provided by external relief
3 P RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Static Signal (PFRS)
Typical application pressure (all ports) 240 bar (3500 psi)
CF EF Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
4 2 Rated inlet flow 230 L/min (60 USgpm)
Temperature range -40° to 100° C (-40° to 210° F)
LS 5 1
Cavity C–20–5S
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
3 P Filtration Cleanliness code 18/16/13
Housing materials (standard) Steel
Profile View Weight cartridge only 0,86 kg (1.9 lbs.)
Seal kit 02-187543
Internal leakage 164 cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.047” (not included in valve)

Pressure Drop Curves


Flow - L/min
5 LS Cartridge only 75 151 227
400

4 CF 350
Pressure drop psi

Pressure drop bar

300 21
3 P 250
200 14
2 EF 150
Note
Minimum inlet flow should 100 7
not be less than 1/4 of
maximum inlet flow. 50
0
Note Minimum pressure drop 0 10 20 30 40 50 60 70
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF

F-36 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code PFRS/D-20

PFR* 20 U * *** *** 00

1 2 3 4 5 6 7

1 Function 5 Ports* 6 Control Pressure

PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 080 psi (5.5 bar)
PFRD – Priority flow regulator 100 psi (6.9 bar)
000 No Body – – –
Dynamic signal type PFRD options
12T SAE 12 SAE 4 4993513-001 4994810-001 085 psi (5.9 bar)
2 Size 16T SAE 16 SAE 4 4993513-002 4994810-002 110 psi (7.6 bar)
20 – 20 Size 06G 3/4” BSPP 1/4” BSPP 4993513-003 4994810-003 7
F
Special features
3 08G 1” BSPP 1/4” BSPP 4993513-004 4994810-004
Seals 00 – None
* These model digits will not be stamped on the valve. (Only required if valve has
U– Urethane (standard)
See section J for housing details. special features, omitted
4 Body if “00”.)
O – Cartridge only
A – Aluminum
S – Steel (standard)

Dimensions
mm (inch)

Torque cartridge in housing 1 7/8 HEX.


A – 130-155 Nm (95-115 ft. lbs) 20,3 (.80)
S – 160–180 Nm (120–135 ft. lbs)

1 5/8 -12 UN-2A


Note
Standard housings include 5 LS
port 1, however for most
applications this port must
be blocked. 4 CF
105,2 (4.14)

3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-37


MRV2-10
Manual rotary flow
control valve

Description Operation
The MRV2-10 is a 2-way, This valve will increase or rotary adjustment.
2 position, manual decrease flow by changing Recommended flow path
semi-rotary screw-in flow the variable orifice with the is 2 to 1.
restrictor valve. RATINGS AND SPECIFICATIONS
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 05 – 0-18,9 L/min (0–5 USgpm)
10 – 0-37,8 L/min (0–10 USgpm)
15 – 0-56,7 L/min (0–15 USgpm)
Internal leakage 164 cm3 /min. (10 in3/min)
maximum 210 bar (3000 psi)
Functional Symbol Temperature range -40° to 120°C (-40° to 248°F)
Manual operators B – Ball lever (friction lock)*
E – Ball lever (10 position detent)*
2 1 D – Lever (10 position detent)*
L – Lever (friction lock)*
*Light duty housings only K – Knob (non-locking)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 561810 Buna-N
Sectional View 889609 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Cartridge only
@ 5,5 bar (80 psi)
pressure drop
Flow - L/min (21,8 cSt oil @ 49°C)
10 20 30 40 50 60
Rated flow 9
A B
2 C
(See model code 8
position 6)
Knob lever position

7
A - 05
1 6
B - 10
5
C - 15
4
3
2
1
0
0 2 4 6 8 10 12 14
Flow - USgpm (105 SUS oil @ 120°F)

F-38 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code MRV2-10

MRV2 – 10 (V) – * – ** – **– 00

1 2 3 4 5 6 7

1 Function 4 Adjustment 5 Port size 6 Port size

MRV2 – Manual rotary valve 0 – No operator 0 – Cartridge only 0 – Cartridge only


B – Ball lever CODE PORT SIZE HOUSING NUMBER
2 Size (friction lock)*
Aluminum Aluminum
10 – 10 Size E – Ball lever Light duty Fatigue rated
(10 position detent)*
3 Seals D – Lever 3B 3/8” BSPP 02-175462 –
Blank– Buna-N (10 position detent)* 6T SAE 6 566151 – F
V – Viton® L – Lever (friction lock)* 2G 1/4” BSPP – 876702
K – Knob (non-locking)
* Light duty housings only.
3G 3/8” BSPP – 876703
6H SAE 6 – 876700
8H SAE 8 – 876701
See section J for housing details.

Dimensions 6 Max flow ranges 7 Special features


mm (inch) (nominal) 00 – None
Torque cartridge in aluminum 05 – 0–18,9 L/min (0–5 USgpm) (Only required if valve has
housing 47–54 Nm (35–40 ft.lbs) 10 – 0–37,8 L/min (0–10 special features, omitted
USgpm) if “00”.)
15 – 0–56,7 L/min (0–15 USgpm)
MRV2-10-K Knob Operated MRV2-10-B/E Models MRV2-10-D/L Models
Arrow can be re-located by
slacking the plate. Re-tighten nut. Ø25,4 (1.00) 41,0
(1.60)

41,0 38,1
(1.60) 58,0
(1.50) X (2.28)
X X X

42,0 42,0
(1.65) (1.65)

MRV2-10-E/D Models MRV2-10-B/L Models


37,0
(1.45) 17,0 Locating
(0.67) Locating pin hole
25,4 (1.00) hex pin hole

0.875"-14 Thd.
31,7
(1.25) 2
Ø3,45-3,50 0
(#29 or 0.136+0.002)
1 x 4,76 (0.187)
Ø15,80 (0.622) in mating housing

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-39


MRV2-16
Manual rotary valve

Description Operation
The MRV2-16 is a 2-way, 2 This valve will increase or Recommended flow path
position, manual semi- decrease flow by changing is 2 to 1.
rotary screw-in flow restric- the variable orifice with the
tor valve. rotary adjustment.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 10 – 0-37,8 L/min (0–10 USgpm) 30 – 0-113,5 L/min (0–30 USgpm)
15 – 0-56,7 L/min (0–15 USgpm) 35 – 0-132,4 L/min (0–35 USgpm)
20 – 0-75,7 L/min (0–20 USgpm) 40 – 0-151,4 L/min (0–40 USgpm)
Functional Symbol 25 – 0-94,6 L/min (0–25 USgpm) 45 – 0-170,3 L/min (0–45 USgpm)
Internal leakage 82 cm3 /min. (5 in3 /min
maximum 210 bar (3000 psi)
2 1 Temperature range -40° to 120°C (-40° to 248°F)
Manual operators D – Lever (10 position detent)
L – Lever (friction lock)
K – Knob (non-locking)
Light duty housings only
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Sectional View Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 561810 Buna-N
889609 Viton®®
Viton is a registered trademark of E.I. DuPont
Pressure Drop Curve Rated flow
Cartridge only (See model code position 6)
A - 10 E - 30
@ 5,5 bar (80 psi) B - 15 F - 35
pressure drop C - 20 G - 40
Flow - L/min (21,8 cSt oil @ 49°C) D - 25 H - 45

20 40 60 80 100 120 140 160 180


2 9
A B C D E F G H
8
Knob lever position

7
1
6
5
4
3
2
1

0 4 8 12 16 20 24 28 32 36 40 44
Flow - USgpm (105 SUS oil @ 20°F)

F-40 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code MRV2-16

MRV2 – 16 (V) – * – *** – **– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Max flow ranges


MRV2 – Manual rotary valve 0 – Cartridge only (nominal)
CODE PORT SIZE HOUSING NUMBER 10 – 0-37,8 L/min
2 Size (0-10 USgpm)
Aluminum Aluminum
16 – 16 Size Light duty Fatigue rated 15 – 0-56,7 L/min
(0-15 USgpm)
3 Seals 6B 3/4” BSPP 02-175463 – 20 – 0-75,7 L/min
Blank– Buna-N 12T SAE 12 566149 – (0-20 USgpm) F
V – Viton® 4G 1/2” BSPP – 876716 25 – 0-94,6 L/min
(0-25 USgpm)
6G 3/4” BSPP – 876718
4 Adjustment 30 – 0-113,5 L/min
10H SAE 10 – 876717 (0-30 USgpm)
0 – No operator
D – Lever (10 position 12H SAE 12 – 566113 35 – 0-132,4 L/min
detent)* See section J for housing details. (0-35 USgpm)
L – Lever (friction lock)* 40 – 0-151,4 L/min
K – Knob (non-locking) (0-40 USgpm)
* Light duty housings only. 45 – 0-170,3 L/min
(0-45 USgpm)
7 Special features
Dimensions 00 – None
mm (inch) (Only required if valve has
special features, omitted
Torque cartridge in aluminum
if “00”.)
housing 108–122 Nm (80–90 ft.lbs)

MRV2-16-K Knob Operated MRV2-16-D/L Models


58,0
(2.28)

76,0
X X (3.00)

6,0
(2.40)

MRV2-16-D Models MRV2-16-L Models


46,0 24,8 Locating
(1.81) Locating pin hole
(0.98) pin hole
38,1 (1.50) hex
1.312"-12 Thd.
44,4
(1.75) 2 Ø3,45-3,50
(#29 or 0.136+00.002)
1 x 4,76 (0.187)
Ø28,55 (1.124) in mating housing

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-41


NV1-8
Needle valve

Description Operation
The NV1–8 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in either wise.
direction, from full flow to
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) steel housing
210 bar (3000 psi) aluminum housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow 45 L/min (12 USgpm)
Internal leakage 5 drops/min. maximum @ 350 bar (5000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 2
Cavity C–8–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,07 kg. (0.15 lbs.)
Seal Kits 02-165875 Buna–N
02-165877 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View Pressure Drop Curve


Cartridge only
Full open
Port 1 to port 2
or port 2 to port 1.

Flow - L/min (21,8 cSt oil @ 49°C)


0 10 20 30 40
200
12
Pressure drop - bar
Pressure drop - psi

150

2
8
100

1
4
50

0 0
0 5 10 12
Flow - USgpm (105 SUS oil @ 120°F)

F-42 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code NV1-8

NV1 – 8 (V) – * – (*) – **– 00

1 2 3 4 5 6 7

1 Function 6 Port size 7 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


CODE PORT SIZE HOUSING NUMBER (Only required if valve has
2 Size special features, omitted
Aluminum Steel
8 – 8 Size Fatigue rated Fatigue rated if “00”.)

3 4T SAE 4 02–160730 02-160736


Seals
6T SAE 6 02–160731 02-160737 F
Blank– Buna-N
V – Viton® 8T SAE 8 02–160732 02–160738
2G 1/4” BSPP 02–160727 02-160733
4 Style 3G 3/8” BSPP 02–160728 02-160734
S – Screw See section J for housing details.
C – Cap
K – Knob
5 Valve housing material

Omit for cartridge only


S – Steel
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in
aluminum or steel housing
to 34–41 Nm (25–30 ft.lbs)
"C" Adjustment

12,7 (.50) hex


33,3
(1.31)

0.750"–16 Thd.

22,1 (0.87) hex


27,8 Aluminum hous-
(1.09) ings can be used
2
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
1
for operating pressures above
Ø12,62 (0.497) 210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-43


NV1-10
Needle valve

Description Operation
The NV1–10 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in either wise.
direction, from full flow to
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Functional Symbol Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 2 Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg. (0.24 lbs.)
Seal Kits 565806 Buna–N
889627 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Pressure Drop Curve Fully open port 1 to port 2


Cartridge only or port 2 to port 1

Flow - L/min (21,8 cSt oil @ 49°C)


5 10 15 20 25 30 35 40 45

5
Pressure drop - bar

70
Pressure drop - psi

60 4
50
2 3
40
30 2
1
20
1
10
0 0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)

F-44 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code NV1-10

NV1 – 10 (V) – * – **– 00

1 2 3 4 5 6

1 Function 5 Port size 6 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


(Only required if valve has
2 CODE PORT SIZE HOUSING NUMBER
Size special features, omitted
Aluminum Aluminum if “00”.)
10 – 10 Size Light duty Fatigue rated
3 Seals 3B 3/8” BSPP 02–175462 –
Blank– Buna-N 6T SAE 6 566151 – F
V – Viton® 2G 1/4” BSPP – 876702
4 3G 3/8” BSPP – 876703
Style
6H SAE 6 – 876700
K – Knob (black)
R – Knob (red) 3G SAE 8 – 876701
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
47–54 Nm (35–40 ft.lbs)

Ø42,0
(1.65)

43,0
(1.69)

25,4 (1.00) hex

0.875"-14 Thd.
31,7
(1.25) 2

1
Ø15,80 (0.622)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-45


NV1-16
Needle valve

Description Operation
The NV1–16 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to

2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical Typical application pressure (all ports) 210 bar (3000 psi)
direction Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
of flow
Rated flow 151 L/min (40 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,34 kg. (0.76 lbs.)
Seal kits 565810 Buna–N
889609 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Full open port 2 to port 1


Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C)


0 20 40 60 80 100 120 140

2
70 5

1 60
Pressure drop - bar
Pressure drop - psi

4
50
Application Note 3
40
The valve is not intended
for use at low flows, may 30
chatter below 10 L/min 2
(2.5 gpm) 20
1
10

0
0 10 20 30 40
Flow - USgpm (105 SUS oil @ 20°F)

F-46 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code NV1-16

NV1 – 16 (V) – K – ***– 00

1 2 3 4 5 6

1 Function 5 Port size 6 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


CODE PORT SIZE HOUSING NUMBER (Only required if valve has
2 Size special features, omitted
Aluminum Aluminum
16 – 16 Size Light duty Fatigue rated
if “00”.)

3 Seals 6B 3/4” BSPP 02–175463 –


Blank– Buna-N 12T SAE 12 566149 – F
V – Viton® 4G 1/2” BSPP – 876716
6G 3/4” BSPP – 876718
4 Style
10H SAE 10 – 876717
K – Knob (black)
R – Knob (red) 12G SAE 12 – 566113
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
108–122 Nm (80–90 ft.lbs)

Ø61,0
(2.40)

61,0
(2.40)

38,1 (1.50) hex


1.312"-12 Thd.

44,4
(1.75) 2

1
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-47


NV1-20
Needle valve

Description Operation
The NV1–20 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Typical Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
direction
of flow Rated flow 265 L/min (70 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
1 Cavity C–20–2
Fluids All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum
Weight cartridge only 0,59 kg. (1.3 lbs.)
Seal kits 889615 Buna-N
889619 Viton ®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Full open port 2 to port 1.


Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C)


0 40 80 120 160 200 240
70 5
2
60
4
Pressure drop - bar
Pressure drop - psi

1 50

40 3

Application Note 30 2
The valve is not intended
20
for use at low flows, may
chatter below 10 L/min 1
10
(2.5 gpm)
0 0
0 10 20 30 40 50 60 70
Flow - USgpm (105 SUS oil @ 120°F)

F-48 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code NV1-20

NV1 – 20 (V) – * – ***– 00

1 2 3 4 5 6

1 Function 5 Port size 6 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


CODE PORT SIZE HOUSING NUMBER (Only required if valve has
2 Size special features, omitted
Aluminum Aluminum
20 – 20 Size Light duty Fatigue rated if “00”.)

3 Seals 8B 1” BSPP 02–175464 –


Blank– Buna-N 16T SAE 16 566409 – F
V – Viton® 6G 3/4” BSPP – 876732
8G 1” BSPP – 876734
4 Style
12H SAE 12 – 876733
K – Knob (black)
16H SAE 16 – 876735
R – Knob (red)
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
128–155 Nm (95–115 ft.lbs)

Ø61,0
(2.40)

62,0
(2.44)
47,6 (1.87) hex

1.625"-12 Thd.
57,1
(2.25)
2

1
Ø36,47 (1.436)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-49


FCV7-10
Flow control valve

Description Operation
The FCV7-10 is a non- This valve when applied turned counterclockwise. In above allowing flow
pressure compensated, without the free flow check the full clockwise position between port 2 and port 1,
adjustable, flow restrictor will allow flow between this valve provides tight while it allows free reverse
available with and without ports 1 and 2 through an shut-off. When applied with from port 1 to port 2.
free-flow check. increasing variable orifice the free flow check, the
when the adjustment is valve will work as stated

Functional Symbols RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
FCV7-10(V)-*-FF/10/20/40

2 Typical application pressure (all ports) 210 bar (3000 psi)


FCV7-10(V)-*-NV(F)

2 Rated flow 45 L/min (12 USgpm)


Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
1 1 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration ISO 4406, class 18/16/13 or cleaner
Sectional Views Standard housing materials Aluminum
Weight cartridge only 0,11 kg (0.25 lbs.)
Seal kits 565806 Buna N
889627 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Cartridge only Typical Flow Regulation (full open)
2 2
Flow - L/min (21,8 cSt oil @ 49°C)
"FF" "10,20,40" "NV" 4,8 14,4 24,0 33,6 43,2
1 1
"NVF"
9,6 19,2 28,8 38,4 48,0
3000 200
Pressure drop - psi

Pressure drop - bar


A B C D E
CURVE CODE FLOW, VALVE 2400 160
OPTION* DIRECTION CONDITION F
PORT: 1800 120
A 10 2 to 1 Open 1200 80
1 to 2 Closed G
B 20 2 to 1 Open 600 40
1 to 2 Closed
0 0
C 10 1 to 2 Open
D 40 2 to 1 Open
1 to 2 Closed 300 20
Pressure drop - psi

Pressure drop - bar

E NVF Both directions Open H


240 16
F 20 1 to 2 Open I
180 12
G 40 1 to 2 Open
120 J
H FF 2 to 1 Open 8
I FF 1 to 2 Open & closed 60 4
J NV Both directions Open
0 0
*See controlled flow option in model code. 0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)

F-50 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FCV7-10

FCV7 – 10 (V) – * – **– ***– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Special features

FCV7 – Flow regulator 0 – Cartridge only 00 – None


CODE PORT SIZE HOUSING NUMBER (Only required if valve has
2 Size special features, omitted
Aluminum Aluminum
10 – 10 Size Light duty Fatigue rated if “00”.)

3 Seals 3B 3/8” BSPP 02–175462 –


Blank– Buna-N 6T SAE 6 566151 – F
V – Viton® 2G 1/4” BSPP – 876702
3G 3/8” BSPP – 876703
4 Style
6H SAE 6 – 876700
C – Cap
K – Knob 8H SAE 8 – 876701
S – Screw See section J for housing details.

6 CONTROLLED FLOW OPTION MAXIMUM FLOW RANGE (NOMINAL)


NV Needle valve 0-45 L/min (0-12 USgpm)
NVF Needle valve, fine 0-38 L/min (0-10 USgpm)
FF Needle valve with free reverse flow 0-45 L/min (0-12 USgpm)
10 Flow range, type 10, with free reverse flow 0-6,6 L/min (0-1.75 USgpm)
20 Flow range, type 20, with free reverse flow 0-14 L/min (0-3.75 USgpm)
40 Flow range, type 40, with free reverse flow 0-27 L/min (0-7.25 USgpm)
Dimensions
mm (inch)
"K" Adjustment "C" Adjustment
Torque cartridge in
aluminum housing to Ø38,1
(1.50)
47–54 Nm (35–40 ft.lbs)

5,1 (0.20) max. travel 44


(1.73) "S" Adjustment
4,8 (0.18) hex
30,2 19,1 (0.75) hex
(1.18)
25,4 (1.00) hex

0.875"-14 Thd.
31,7
(1.25)
2

1
Ø15,82 (0.623)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-51


FCV11-12
Flow control valve

Description Operation
The FCV11–12 is a direct This valve is non-pressure from full flow to tight shut
acting, adjustable needle compensated. Flow is con- off, by turning the adjust-
valve. trolled in either direction, ment feature clockwise.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure 350 bar (5000 psi) Port “1” to “2”
210 bar (3000 psi) Port “1” to “2”
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
Internal leakage less than 5 drops / min. max. @210 bar (3000 psi)
2
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-2 or C-12-2U
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
1 Weight cartridge only 0,24 kg (0.54 lb.)
Seal kit 02–165889 Buna–N
02–165888 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View
Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60 80 100
90 6,21
A – Cartridge with C-12-2
valve body, full open 80 5,52

Pressure drop - bar


B – Cartridge with C-12-2U 70 4,83
Pressure drop - psi

valve body, full open A


60 4,14
C – Cartridge only, full B
open 50 3,45
40 C
2,5
30 2,0
2
20 1,0
10 0,5
1
0
0 5 10 15 20 25 30

Flow - USgpm (105 SUS @ 120°F)

F-52 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FCV11-12

FCV11 – 12 (V) – S – *– ***– (U) – NV – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port size

FCV11 – Flow control valve 0 – Cartridge only


CODE PORT SIZE HOUSING NUMBER
2 Size
C-12-2U C-12-2 C-12-2U C-12-2
12 – 12 Size Aluminum Aluminum Steel Steel
Fatigue rated Fatigue rated Fatigue rated Fatigue rated
3 Seals
10T(U) SAE 10 02–160641 02–160640 02–169817 02–169744
Blank– Buna-N F
12T(U) SAE 12 02–160645 02–160644 02v169790 02–169782
V – Viton®
4G(U) 1/2” BSPP 02–161116 02–161118 02–172512 02–172062
4 Adjustment 6G(U) 3/4” BSPP 02–161115 02–161117 02–162922 02–169665
S – Screw See section J for housing details.
Note: C-12-2U housings have undercut for improved flow.
5 Valve housing material

S – Steel
A – Aluminum 7 8 Valve type 9
Cavity Special features
Blank – Cavity without NV – Needle Valve 00 – None
undercut (Adjustable) (Only required if valve has
U – Cavity with undercut special features, omitted
Dimensions if “00”.)
mm (inch)

Torque cartridge in housing


A – 81–95 Nm (60–70 ft.lbs) "S" Adjustment
S – 102–115 Nm (75–85 ft.lbs) 3,2 (0.12) hex
40,0
(1.60)

31,8 (1.25) hex

1.063"–12
Thd.
44,6
(1.80)

2
Aluminum hous-
ings can be used
• for pressures up to
1 210 bar (3000 psi)
Ø23,75 (0.935) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-53


FCV6-16
Flow control valve

Description Operation
The FCV6-16 is a non-pres- This valve allows flow counterclockwise. In the full
sure compensated, between ports 1 and 2 clockwise position this valve
adjustable, flow restrictor. through an increasing provides tight shut-off.
variable orifice when the
Functional Symbol adjustment is turned

2 RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 208 L/min (55 USgpm)
Internal leakage Port 2 to 1; <5 drops/min
maximum @ 210 bar (3000 psi)
1
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,37 kg (0.81 lbs.)
Seal kits 889631 Buna-N
889635 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Full open port 1 to port 2


Cartridge only or port 2 to port 1

Flow - L/min (21,8 cSt oil @ 49°C)


0 40 80 120 160 200
100 7
90
2 6
Pressure drop - bar
Pressure drop - psi

80
70 5
1 60 4
50
3
40
30 2
20
1
10
0
0 10 20 30 40 50 60
Flow - USgpm (105 SUS @ 120°F)

F-54 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FCV6-16

FCV6 – 16 (V) – * – *** – NV– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Controlled flow option

FCV6 – Flow control valve 0 – Cartridge only NV – Needle valve


2 Size CODE PORT SIZE HOUSING NUMBER 7 Special features

16 – 16 Size Aluminum Aluminum 00 – None


Light duty Fatigue rated (Only required if valve has
3 Seals special features, omitted
6B 3/4” BSPP 02–175463 –
Blank– Buna-N 12T SAE 12 566149 – if “00”.) F
V – Viton®
4G 1/2” BSPP – 876716
4 Style 6G 3/4” BSPP – 876718
C – Cap 10H SAE 10 – 876717
K – Knob 12H SAE 12 – 566113
S – Screw See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft.lbs)
"S" Adjustment
4,8 (0.18) hex "C" Adjustment
"K" Adjustment 19,1 (0.75) hex
Ø38,1 (1.50)

59,0
51,0 51,0 (2.32)
(2.00) (2.00)
38,1 (1.5) hex

1.312" -12 Thd.


44,7
(1.76)
2

1
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-55


VF1-10
Velocity fuse

Description Operation
The VF1-10-F is a screw-in This valve is normally open setting of the valve, it clos- pressure at port 1 is
cartridge velocity fuse. from port 1 to port 2. When es. The valve returns to the reduced to less than 80 psi.
flow exceeds the open condition when the
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
Flow regulation accuracy 1,9–22,7 L/min (0.5–6.0 USgpm) ±20%
1 Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Internal leakage Port 2 to 1; <5 drops/min
maximum @ 210 bar (3000 psi)
Fusing Reverse
direction flow Temperature range -40° to 120°C (-40° to 248°F)
direction Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg (0.25 lbs.)
Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation

2
Cartridge only
A -22,8 L/min (6 USgpm)
maximum flow setting Pressure drop - bar
Port 1 to 2, fusing 0 3 7 10 14 17 20
1 direction 8 30
(105 SUS oil @ 120°F)

Port 2 to 1, reverse
(21,8 cSt oil @ 49°C)
flow down to 0 25
Flow - L/min
6
Flow - USgpm

B -14,44 L/min (3 USgpm) 20


maximum flow setting A
Application Note Port 1 to 2, fusing 4 15
The valve is not intended direction
for use in pump unloading 10
Port 2 to 1, reverse 2 B
applications flow down to 0 5
C
C -3,8 L/min (1 USgpm)
maximum flow setting 0
0 45 100 150 200 250 300
Port 1 to 2, fusing Pressure drop - psi
direction
Port 2 to 1, reverse
flow down to 0

F-56 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code VF1-10

VF1 – 10 (V) – F – ** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

VF1 – Velocity fuse 0 – Cartridge only nominal


(Specify in USgpm)
2 CODE PORT SIZE HOUSING NUMBER
Size Range 1,9–22,7 L/min
Aluminum Aluminum (0.5)–6.0 USgpm)
10 – 10 Size
Light duty Fatigue rated
3 Seals 3B 3/8” BSPP 02–175462 – 7 Special features
Blank– Buna-N 6T SAE 6 566151 – 00 – None F
V – Viton® 2G 1/4” BSPP – 876702 (Only required if valve has
special features, omitted
4 3G 3/8” BSPP – 876703 if “00”.)
Adjustment
F – Fixed orifice 6H SAE 6 – 876700
8H SAE 8 – 876701
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing to
47–54 Nm (35–40 ft.lbs)

19,0 25,4 (1.00) hex


(0.75)

0.875"-14 Thd.
31,7
(1.25)
2

1
Ø15,82 (0.623)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-57


VF1-16
Velocity fuse

Description Operation
The VF1-16-F is a factory- This valve is normally open condition when the pres-
set, screw-in cartridge from port 1 to port 2. When sure at port 1 is reduced to
velocity fuse. flow exceeds the setting of less than 80 psi.
the valve, it closes. The
valve returns to the open

RATINGS AND SPECIFICATIONS


Functional Symbol
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 114 L/min (30 USgpm)
Flow regulation accuracy 9,5–114 L/min (2.5–30.0 USgpm) ±20%
1 Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Internal leakage Port 1 to 2 closed; <5 drops/min
maximum @ 210 bar (3000 psi)
Fusing Reverse Temperature range -40° to 120°C (-40° to 248°F)
direction flow direction
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,33 kg (0.72 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation


Cartridge only

2 A -114 L/min (30 USgpm)


maximum flow setting
Port 1 to 2, fusing Pressure drop - bar
direction 0 3 7 10 14 17 20
1 Port 2 to 1, reverse 40 150
flow down to 0
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)

B -60 L/min (15 USgpm) 125


Flow - L/min

30
Flow - USgpm

maximum flow setting


Application Note 100
Port 1 to 2, fusing A
The valve is not intended direction 20 75
for use in pump unloading
applications Port 2 to 1, reverse B
50
flow down to 0 10
C -19 L/min (5 USgpm) C 25
maximum flow setting
0
Port 1 to 2, fusing 0 45 100 150 200 250 300
direction
Pressure drop - psi
Port 2 to 1, reverse
flow down to 0

F-58 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code VF1-16

VF1 – 16 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

VF1 – Velocity fuse 0 – Cartridge only nominal


CODE PORT SIZE HOUSING NUMBER (Specify in USgpm)
2 Size Range 9,5-114 L/min
Aluminum Aluminum
16 – 16 Size Light duty Fatigue rated (2.5-30.0 USgpm)

3 6B 3/4” BSPP 02–175463 – 7 Special features


Seals
Blank– Buna-N 12T SAE 12 566149 – 00 – None F
V – Viton® 4G 1/2” BSPP – 876716 (Only required if valve has
6G 3/4” BSPP – 876718 special features, omitted
4 Style if “00”.)
10H SAE 10 – 876717
F – Factory set
12H SAE 12 – 566113
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft. lbs)
38,1 (1.5) hex
29,0
(1.13)

1.312"-12 Thd.
44,5
(1.75)
2

1
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-59


VF1-20
Velocity fuse

Description Operation
The VF1-20-F is a factory- This valve is normally open valve returns to the open
set, screw-in cartridge from port 1 to port 2. When condition when the pres-
velocity fuse. flow exceeds the setting of sure at port 1 is reduced to
the valve, it closes. The less than 80 psi.
RATINGS AND SPECIFICATIONS
Functional Symbol Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
2 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 227 L/min (60 USgpm)
Flow regulation accuracy 60–227 L/min (15–60 USgpm) ±20%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
1 Internal leakage (Port 1 to 2 closed) 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Fusing Reverse Cavity C–20–2
direction flow direction Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum
Weight cartridge only 0,82 kg. (1.80 lbs.)
Seal kits 889615 Buna–N
889619 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation


Cartridge only

2
A -228 L/min (60 USgpm)
maximum flow setting
Port 1 to 2, fusing
1 direction Pressure drop - bar
Port 2 to 1, reverse 0 3 7 10 14 17 20
flow down to 0 80 300
B -114 L/min (30 USgpm)
250
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)

maximum flow setting


60
Flow - L/min

Application Note Port 1 to 2, fusing


Flow - USgpm

A 200
The valve is not intended direction
for use in pump unloading Port 2 to 1, reverse 40 150
applications flow down to 0
C -38 L/min (10 USgpm) 100
B
maximum flow setting 20
C 50
Port 1 to 2, fusing
direction
0
Port 2 to 1, reverse 0 45 100 150 200 250 300
flow down to 0
Pressure drop - psi

F-60 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code VF1-20

VF1 – 20 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

VF1 – Velocity fuse 0 – Cartridge only nominal


CODE PORT SIZE HOUSING NUMBER (Specify in USgpm)
2 Size Range 60-227 L/min
Aluminum Aluminum
20 – 20 Size Light duty Fatigue rated (15-60.0 USgpm)

3 8B 1” BSPP 02–175464 – 7 Special features


Seals
Blank– Buna-N 16T SAE 16 566409 – 00 – None F
V – Viton® 6G 3/4” BSPP – 876732 (Only required if valve has
8G 1” BSPP – 876734 special features, omitted
4 Style if “00”.)
12H SAE 12 – 876733
F – Factory set
16H SAE 16 – 876735
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing to
128–155 Nm (95–115 ft. lbs) 38,1 47,6 (1.87) hex
(1.50)

1.625"-12 Thd.
57,2
(2.25)
2

1
Ø36,47 (1.436)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-61


FDC1-10
Flow divider/combiner

Description Operation
The FDC1-10 is a pressure This valve is used in the regardless of system pres- flows from ports 2 and 4
compensated, spool type, dividing mode. It will take sure to ports 2 and 4. and combine them into port
screw-in, flow divider/com- the inlet flow (port 3) and In the combining mode this 3 according to the ratio
biner cartridge. split the flow according to valve will take the inlet specified.
the ratio specified,

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Temperature range -40° to 120°C (-40° to 248°F)
2 4
Cavity C–10–4
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
3 Standard housing materials Aluminum
Weight cartridge only 0,10 kg. (0.22 lbs.)
Seal Kits 889625 Buna–N
566080 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View Typical Flow Regulation Flow Division


Cartridge only (See model code position 5)
A - 3* spool
B - 4* spool
C - 6* spool
D - 8* spool

Flow - L/min (21,8 cSt oil @ 49°C)


4
15 30 45 60
800
A B 50
700
Pressure drop - bar
Pressure drop - psi

3 C D
600 40
500
30
2 400
300 20
200
10
100
Note 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Port 1 unused, blocked by
blind cavity Flow - USgpm (105 SUS oil @ 120°F)

F-62 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FDC1-10

FDC1 – 10 (V) – ** – **– 00

1 2 3 4 5 6

1 Function 5 Flow divisions (ratios)


FDC1 – Flow divider/ CODE FLOW DIVISION% RATED INLET FLOW
combiner Port 4 Port 2 L/min (USgpm)
2 Size 5.1 33 67 5,7 (1.5)
5.5 50 50 3,8 (1)
10 – 10 Size 11 50 50 7,6 (2)
21 67 33 11,4 (3)
3 Seals 22 50 50 15,2 (4) F
Blank– Buna-N 33 50 50 22,8 (6)
V – Viton® 34 43 57 26,6 (7)
36 33 67 34,2 (9)
4 Port size 43 57 43 26,6 (7)
44 50 50 30,4 (8)
0 – Cartridge only 46 40 60 38,0 (10)
CODE PORT SIZE HOUSING NUMBER 62 75 25 30,4 (8)
63 67 33 34,2 (9)
Aluminum 64 60 40 38,0 (10)
3B 3/8”BSPP 02–175467* 66 50 50 45,6 (12)
88 50 50 60,8 (16)
6T SAE 6 566234*
2G 1/4” BSPP 02–185804
3G 3/8”BSPP 02–185805 7 Special features
6H SAE 6 02–185802 00 – None
8H SAE 8 02–185803 (Only required if valve has
*Light duty housing special features, omitted
See section J for housing details. if “00”.)

8,0
(0.31) 25,4 (1.00) hex

Dimensions 0.875"-14 Thd.


mm (inch)
4
Torque cartridge in
aluminum housing to
47–54 Nm (35–40 ft.lbs) 63,9
(2.51) 3

Notes
Port 1, unused, blocked by 2
blind cavity.

Minimum inlet flow should


not be less than 1/4 of Ø15,80 (0.622)
maximum inlet flow for Ø17,40 (0.685)
a given code. Ø18,97 (0.747)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-63


FDC1-16
Flow divider/combiner

Description Operation
The FDC1-16 is a pressure This valve is used in the regardless of system pres- flows from ports 2 and 4
compensated, spool type, dividing mode. It will take sure to ports 2 and 4. and combine them into port
screw-in, flow divider/com- the inlet flow (port 3) and In the combining mode this 3 according to the ratio
biner cartridge. split the flow according to valve will take the inlet specified.
the ratio specified,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Temperature range -40° to 120° C (-40° to 248° F)
2 4 Cavity C–16–4
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
3 Standard housing materials Aluminum
Weight cartridge only 0,35 kg (0.78 lbs.)
Seal Kits 889634 Buna–N
889638 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View Typical Flow Regulation Flow Division


Cartridge only (See model code position 5)
A - 2* spool
B - 3* spool
C - 4* spool
D - 5* spool
E - 6* spool
F - 8* spool
4
Flow - L/min (21,8 cSt oil @ 49°C)
50 100 150 200
800
3
A B C D 50
700
Pressure drop - bar
Pressure drop - psi

E
600 40
2 F
500
30
400
300 20
200
Note 10
100
Port 1 unused, blocked by
blind cavity 0
0 5 10 15 20 25 30 35 40 45 50
Flow - USgpm (105 SUS oil @ 120°F)

F-64 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FDC1-16

FDC1 – 16 (V) – *** – **– 00

1 2 3 4 5 6

1 Function 5 Flow divisions (ratios)


FDC1 – Flow divider/ CODE FLOW DIVISION% RATED INLET FLOW
combiner Port 4 Port 2 L/min (USgpm)
2 Size 22 50 50 45,6 (12)
28 20 80 114,0 (30)
16 – 16 Size 33 50 50 68,0 (18)
36 33 67 98,0 (26)
3 Seals 43 57 43 79,0 (21) F
Blank– Buna-N 44 50 50 90,0 (24)
V – Viton® 46 40 60 114,0 (30)
55 50 50 114,0 (30)
4 Port size 62 75 25 90,0 (24)
63 67 33 98,0 (26)
0 – Cartridge only 64 60 40 114,0 (30)
CODE PORT SIZE HOUSING NUMBER 66 50 50 132,0 (35)
82 80 20 114,0 (30)
Aluminum Light duty 84 67 33 132,0 (35)
12T SAE 12 566200 88 50 50 178,0 (47)
6B 3/4” BSPP 02-175468
See section J for housing details.
6 Special features
00 – None
(Only required if valve has
special features, omitted
if “00”.)

Dimensions
mm (inch) 13,0
(0.51) 38,1 (1.50) hex
Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft. lbs) 1.312"-12 Thd.
4
Notes
Port 1, unused, blocked by
blind cavity. 104,8
(4.12) 3
Minimum inlet flow should
not be less than 1/4 of
maximum inlet flow for
a given code. 2

Ø25,37 (0.999)
Ø26,95 (1.061)
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-65


FDC1-20
Flow divider/combiner

Description Operation
The FDC1-20 is a line This valve is used in the regardless of system pres- flows from ports 2 and 3
mounted pressure dividing mode. It will take sure to ports 2 and 4. and combine them into port
compensated, spool type, the inlet flow (port 1) and In the combining mode this 1 according to the ratio
flow divider/combiner split the flow according to valve will take the inlet specified.
valve. the ratio specified,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Fluids All general purpose hydraulic fluids such as:
2 3 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 2,6 kg. (5.75 lbs.)
1 Seal Kits 889639 Buna–N
889643 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Pressure Drop Curves Flow Division:


(See model code position 5)
A - 3* spool
2
B - 4* spool
C - 6* spool
D - 8* spool
1

Inlet flow rate, port 1, - L/min (21,8 cSt oil @ 49°C)


0 100 200 300
3
30
400
Pressure drop - bar
Pressure drop - psi

A
25

300 20
B
15
200
C 10
100
5
D
0
0 20 40 60 80 100
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)

F-66 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FDC1-20

FDC1 – 20 (V) – *** – **– 00

1 2 3 4 5 6

1 Function 5 Flow divisions (ratios) 6 Special features

FDC1 – Flow divider/ CODE FLOW DIVISION% MAX. INLET FLOW 00 – None
combiner Port 4 Port 2 L/min (USgpm) (Only required if valve has
special features, omitted
2 Size 33 50 50 190,0 (50)
34 43 57 228,0 (60) if “00”.)
20 – 20 Size 36 33 67 266,0 (70)
44 50 50 266,0 (70)
3 Seals 46 40 60 304,0 (80) F
Blank– Buna-N 66 50 50 380,0 (100)
V – Viton® 88 50 50 380,0 (100)

4 Port size

16T – SAE 16 (light duty)


20T – SAE 20 (light duty)
(Available as a complete
assembly only.)

178,0 (7.00)
152,4 (6.00) 12,7 (0.50)
Dimensions
mm (inch)
63,5
Torque cartridge in housing (2.50)
128–155 Nm (95–115 ft. lbs) 31,7
(1.25) 2 3

Note
Minimum inlet flow should 31,7 31,7
not be less than 1/4 of 12,7
(1.25) (1.25)
maximum inlet flow for a (0.50)
given code.

101,6 104,0
(4.00) (4.10)

76,2
(3.00)
50,8
(2.00)

44,4 44,4
1 (1.75) (1.75) Ø10,0 (0.406 thru) (3 plcs.)
76,2
(3.00)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-67


FDC3-10
Posi-traction valve

Description Operation
The FDC3-10 is a pressure This valve is used in the In the combining mode this port 3 according to the ratio
compensated, spool type, dividing mode. It will take valve will take the inlet specified.
screw-in, posi-traction the inlet flow (port 3) and flows from ports 2 and 4
cartridge valve. split the flow to ports 2 and combine them into
and 4.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Temperature range -40° to 120° C (-40° to 248° F)
4 2
Cavity C–10–4
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
3 Standard housing materials Aluminum
Weight cartridge only 0,10 kg (0.22 lbs.)
Seal kits 889625 Buna–N
566080 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View Pressure Drop Curves Flow Division


Cartridge only (See model code position 5)
A - 33 spool
B - 44 spool
C - 66 spool
D - 88 spool

Inlet flow rate, port 3, - L/min (21,8 cSt oil @ 49°C)


4
15 30 45 60 75
800
A B C D 50
700
Pressure drop - bar
Pressure drop - psi

3
600 40
500
30
400
2
300 20
200
10
100
0
Note 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Port 1 unused, blocked by Inlet flow rate, port 3, - USgpm (105 SUS oil @ 120°F)
blind cavity

F-68 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FDC3-10

FDC3 – 10 (V) – ** – **– 00

1 2 3 4 5 6

1 Function 3 Seals 5 Flow divisions (ratios)


FDC3 – Posi-traction valve Blank– Buna-N CODE FLOW DIVISION% MAX. INLET FLOW
V – Viton® Port 4 Port 2 L/min (USgpm)
2 Size
33 50 50 22,8 (6.0)
10 – 10 Size 44 50 50 30,4 (8.0)
4 Port size
66 50 50 45,6 (12.0)
0 – Cartridge only 88 50 50 60,8 (16.0)
CODE PORT SIZE HOUSING NUMBER
F
Aluminum
3B 3/8” BSPP 02-175467* 6 Special features

6T SAE 6 566234* 00 – None


2G 1/4” BSPP 02-185804 (Only required if valve has
special features, omitted
3G 3/8” BSPP 02-185805
if “00”.)
6H SAE 6 02-185802
8H SAE 8 02-185803
*Light duty housing
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in 8,0 25,4 (1.00) hex


aluminum housing to (0.31)
47–54 Nm (35–40 ft. lbs)
0.875"-14 Thd.
Notes
4
Port 1, unused, blocked by
blind cavity.
63,9
(2.51) 3
Minimum inlet flow should
not be less than 1/4 of
maximum inlet flow for a 2
given code.

Ø15,80 (0.622)
Ø17,40 (0.685)
Ø18,97 (0.747)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-69


FDC3-16
Posi-traction valve

Description Operation
The FDC3-16 is a pressure This valve is used in the In the combining mode this
compensated, spool type, dividing mode. It will take valve will take the inlet
screw-in, posi-traction the inlet flow (port 3) and flows from ports 2 and 4
cartridge valve. split the flow to ports 2 and combine them into
and 4. port 3 according to the ratio
specified.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbol Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated inlet flow See model code, item
4 2 Temperature range -40° to 120° C (-40° to 248° F)
Cavity C–16–4 (See page 70)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
3
Standard housing materials Aluminum
Weight cartridge only 0,35 kg. (0.78 lbs.)
Seal kits 889634 Buna–N
889638 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View Pressure Drop Curves Flow Division


Cartridge only (See model code position 5)
A - 22 spool
B - 33 spool
C - 44 spool
D - 55 spool
E - 66 spool
F - 88 spool
4 Flow - L/min (21,8 cSt oil @ 49°C)
50 100 150 200
800
A
3 700 50
B
Pressure drop - bar

E
Pressure drop - psi

C D
600 40
F
500
2
30
400
300 20
200
10
Note 100

Port 1 unused, blocked by 0


blind cavity 0 5 10 15 20 25 30 35 40 45 50
Flow - USgpm (105 SUS oil @ 120°F)

F-70 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FDC3-16

FDC3 – 16 (V) – ** – **– 00

1 2 3 4 5 6

1 Function 5 Flow divisions (ratios) 6 Special features

FDC3 – Posi-traction valve CODE FLOW DIVISION % MAX. INLET FLOW 00 – None
Port 4 Port 2 L/min (USgpm)
(Only required if valve has
2 Size special features, omitted
16 – 16 Size 22 50 50 57,0 (15) if “00”.)
33 50 50 76,0 (20)
3 Seals 44 50 50 106,4 (28)
55 50 50 126,2 (34)
Blank– Buna-N 66 50 50 152,0 (40) F
V – Viton® 88 50 50 228,0 (60)
4 Port size
0 – Cartridge only
CODE PORT SIZE HOUSING NUMBER
Aluminum Light duty
12T SAE 12 566200
6B 3/4” BSPP 02-175468
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
108–122 Nm (80–90 ft. lbs) 13,0
38,1 (1.50) hex
(0.51)

Notes 1.312"-12 Thd.


Port 1, unused, blocked by
blind cavity.
4

Minimum inlet flow should 104,8


not be less than 1/4 of (4.13)
3
maximum inlet flow for
a given code.
2

Ø25,37 (0.999)
Ø26,95 (1.061)
Ø28,55 (1.124)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-71


FDC3-20
Posi-traction valve

Description Operation
The FDC3-20 is a line This valve is used in the In the combining mode this port 1 according to the ratio
mounted, pressure dividing mode. It will take valve will take the inlet specified.
compensated, spool type, the inlet flow (port 1) and flows from ports 2 and 3
posi-traction cartridge split the flow to ports and combine them into
valve. 2 and 3.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol
Rated inlet flow See model code
2 3 Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
1 Weight cartridge only 2,6 kg. (5.75 lbs.)
Seal kits (2 req’d.) 889639 Buna–N
889643 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Pressure Drop Curves Flow Division


(See model code position 5)
2 A - 33 spool
B - 44 spool
C - 66 spool
D - 88 spool
1

Inlet flow rate, port 1, - L/min (21,8 cSt oil @ 49°C)


0 100 200 300 400 500 600
3 30
Pressure drop - bar

400
Pressure drop - psi

A C D
350 25
B
300
20
250
200 15
150
10
100
50 5
0
0 20 40 60 80 100 120 140
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)

F-72 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code FDC3-20

FDC3 – 20 (V) – *** – **– 00

1 2 3 4 5 6

1 Function 3 Seals 5 Flow divisions (ratios)


FDC3 – Posi-traction valve Blank – Buna-N CODE FLOW DIVISION% MAX. INLET FLOW
V – Viton® Port 4 Port 2 L/min (USgpm)
2 Size
4 Port size 33 50 50 190,0 (50)
20 – 20 Size 44 50 50 266,0 (70)
16T – SAE 16 (light duty) 66 50 50 380,0 (100)
20T – SAE 20 (light duty) 88 50 50 570,0 (150)
(Available as complete F
assembly only.)
6 Special features

00 – None
(Only required if valve has
special features, omitted
if “00”.)

Dimensions 12,7 (0.50) 152,4 (6.00) 12,7 (0.50)


mm (inch)

Torque cartridge in housing 76,2


128–155 Nm (95–115 ft. lbs) (3.0)

63,5
Note (2.50)
Minimum inlet flow should 31,7
not be less than 1/4 of (1.25) 2 3
maximum inlet flow for
a given code.
12,7 31,7 (1.25) 31,7 (1.25)
(0.50)

101,6
(4.00)
104,0
76,2 (4.10)
(3.00)

44,4 44,4
(1.75) (1.75) Ø10,3 (0.406 thru) (3 plcs.)
1
76,2
(3.00)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 F-73

Anda mungkin juga menyukai