BULLETIN
PCg-2011
ISO 9001
CERTIFIED
www.versa-valves.com
e-mail: sales@versa-valves.com
QUALITY IS
ABSOLUTE
Quality has no degrees at Versa.
There is no such thing as “pretty
WORLDWIDE
good” or “almost right”. Every prod- ACCESSIBILITY
uct is designed and manufactured to
conform to uniformly high standards. representatives and over 100
These standards are assured by stocking locations comprise Versa’s
a quality management system which worldwide distribution system. They
are supported by manufacturing
testing of all products prior to ship- and technical centers in the United
ment. States and The Netherlands.
No matter how tough the appli- The distributor network is the
cation or environmental demands, key to customer service and the
Versa offers you a choice of valves source of continuous application
to meet the challenge. Advanced de- feedback. Versa uses this input as
sign, durable construction materials part of its research and development
and rigid manufacturing standards program in an effort to respond
provide valves you can rely on for to individual and industry needs.
years of trouble-free performance. Versa makes certain that our
Be it a single valve or a pneumatic distributors’ sales and service
system, Versa’s commitment to qual- personnel receive factory training
ity is uncompromising. Count on it. on an ongoing basis. This
includes basic theory, product
indoctrination and seminars.
Our distributor family is a
source of pride to Versa–but more
important—it is a source of support
and service to all of our customers.
Contact Versa for the distributor
THE COMMITMENT
CONTINUES
Fluid Power is our business. It is
our only business, so we have to be
good at it. Since its beginning in 1949,
Versa has maintained its commitment
customers.
Versa has succeeded in serving
industry’s needs with a broad line
of directional control devices. Our
focus on product variety, technical
expertise and company support
remains constant. It all begins with
a responsiveness to industry needs
and ends with delivery of the valve or
system you need–when you need it.
We view ourselves as problem
solvers and that role requires more
than making good products. It is what
we do before and after that is equally
important From drawing board to
user satisfaction, our commitment is
continuous.
CONTENTS GUIDE
Direct Mount Actuator Valves
Bodyported Valves
Aluminum (Series C5 & C7) 3-way & 4 way . ... .. Page 10 -11
Brass (Series V) 3-way & 4 way . .. ... ... .. ... ... .. Page 12 -14
Stainless Steel (Series E & E5) 3-way ... ... .. ... ... .. . Page 15
Stainless Steel (Series C316) 3-way & 4 way . .. Page 16 - 17
Stainless Steel (Series V316) 3-way & 4 way . .. Page 18 - 20
Lockout Valves:
Brass (Series V) or Stainless Steel (Series V316)
3-way and 4-way . . . . . . . . . . . . . . . . . . . . . . . . . . . ............... Page 21
Technical Information:
Non-Hazardous Service Solenoids ....................Page 26 -27
Hazardous Service Solenoids ............................ Page 28 -29
Option Availability ............................................... Page 30-31
3
DIRECT MOUNT ACTUATOR VALVES
SERIES C5 NAMUR
3-Way/4-Way Field Convertible Solenoid Valves
General Description power requirements makes the most exacting and demanding
The Versa C5 NAMUR mount control valve
(guarded-push to operate) are standard on all C5 NAMUR
is designed to mount directly to any NAMUR valves. Consult factory for other manual overrides available as
actuator, thus reducing actuator response an option.
Operating
Pressure Range††
Ordinary Hazardous
Pneumatic
Service Service
Single Solenoid/Spring Return 15-115 psi 0.8 lbs. 1.1 lbs. †† Pressure ranges may change
(2-position) (1-8 bar) (363 g) (500 g) based on solenoid option.
See page 6.
Double Solenoid/Detented 10-115 psi 1.2 lbs. 1.8 lbs. bar
(2-position) (0.7-8 bar) (545 g) (816 g) MPa =
10
Double Solenoid/Spring Centered 15-115 psi 1.2 lbs. 1.8 lbs. For higher pressure applications,
(1-8 bar) (545 g) (816 g) consult factory.
(3-position)
C5 NAMUR Valve
Product Number Selector
Basic Valve Number*
FUNCTION PORT SIZE Cv (Kv) SINGLE SOLENOID/SPRING DOUBLE SOLENOID/ DOUBLE SOLENOID/SPRING CENTERED, 3 POSITION
RETURN, 2 POSITION DETENT, 2 POSITION Blocked Center Exhaust Ports Open
4-way 1/4 NPT .75 (11) CGS-4232-NB1 -†- (coil code) CGG-4232-NB1 -†- (coil code) CXX-4233-NB1 -†- (coil code) CXX-4234-NB1-†- (coil code)
5/2 & 5/3 G1/4 .75 (11) CGS-4292-NB1 -†- (coil code) CGG-4292-NB1 -†- (coil code) CXX-4293-NB1 -†- (coil code) CXX-4294-NB1 -†- (coil code)
3-way** 1/4 NPT .75 (11) CGS-3232-NB1 -†- (coil code) CGG-3232-NB1 -†- (coil code) CXX-3233-NB1 -†- (coil code) CXX-3234-NB1 -†- (coil code)
G1/4 .75 (11) CGS-3292-NB1 -†- (coil code) CGG-3292-NB1 -†- (coil code) CXX-3293-NB1 -†- (coil code) CXX-3294-NB1 -†- (coil code)
3/2 & 3/3
* All valves include O ring interface seals and #10-24 mounting screws.
For #10-32 screws change NB1 to NB2. For M5 screws change NB1 to NB3.
** 3-way is the same valve as 4-way, but is provided with a relocated cylinder port plug. See note on page 7
4
SERIES E5 NAMUR
3-Way Solenoid Valves
General Description Materials
The Versa E5 NAMUR mount control valve is an inexpensive, Valve Body: anodized aluminum
simple and effective 3-way direct-acting solenoid valve. It Valve Seals: body/plunger –NBR (nitrile)
is designed to mount directly to any actuator with NAMUR valve/actuator mounting O rings –NBR (nitrile)
Screws: (valve to actuator) = stainless steel)
It is most effective on spring return or fail-safe actuators where Solenoid Parts: sleeve, plunger & spring – 304 & 430F stainless
high speed open or close is not important, but where cost is a steel
factor. A threaded actuator vent port is standard. coils–epoxy encapsulated with 3 spade
terminals (std) or 2 or 3 wire lead (opt)
Available as a 3-way, 2-position, direct solenoid, spring return coil cover– (when applicable) option:–C50 =
only, and with most of the Versa solenoid options. See page 6. carbon steel, painted;
–LB–XN, –LB–XX, –PC, –PC–XN,
–PC–XX, –XN, –XX= carbon steel,
electroless nickel plated
Operating
Pressure Range
Ordinary Hazardous
Pneumatic
Service Service
Single Solenoid/Spring Return 0-150 psi 0.6 lbs 0.9 lbs
(2-position) (0-10.3 bar) (272 g) (408 g)
Flow Rates
Cv = 0.08 (Kv = 1.2) average for all ports
(5 SCFM at 100 psi; 8.5 Nm3/h at 7 bar).
For actuator speed rates see page 6.
Options
See page 6.
E5 NAMUR Valve
Product Number Selector
Basic Valve Number*
FUNCTION PORT SIZE Cv Kv SINGLE SOLENOID/SPRING RETURN
2-POSITION
3-Way E5SM-3011-34-NB1 -†- (coil code)
A
1/4 NPT .08 (1.2)
G1/4 .08 (1.2) E5SM-3071-34-NB1 -†- (coil code)
3/2 IN EX
* All valves include O ring interface seals and #10-24 mounting screws.
For #10-32 screws change NB1 to NB2.
For M5 screws change NB1 to NB3.
5
DIRECT MOUNT ACTUATOR VALVES
Actuator Volume
in3 (cm3)
Valve 5 10 25 50 100 150 200 400 600 1000
Type (82) (164) (410) (820) (1640) (2460) (3280) (6560) (9840) (16400)
ACTUATOR C5 .32 .36 .47 .63 .98 1.3 1.7 3.1 4.5 7.2
CYCLE TIME
E5 .46 .64 1.1 2.0 3.9 5.7 7.5 - - -
IN
SECONDS C316 .19 .21 .25 .35 .55 .65 1.0 1.5 2.2 3.5
For double-acting actuators (open & close), use volume from chart. Actuator spring loading may affect shift time.
Slower speeds (adjustable) can always be accomplished
estimated speed. The times indicated are per shift. For by using Versa’s Bleed Control Valves in the control
spring return actuators, use open volume to obtain time valve exhaust port (see page 25).
6
SERIES C5 & E5 NAMUR Dimensions Shown as inch
(mm)
Port markings shown are for valves with NPT threads. Port markings for valves with G threads are: (1) = IN; (2) = B;
(3) = EB; (4) = A; (5) = EA. Option -PC is shown for reference.
.47
(12) .15
1/4” NPT (38) LOCATING HOLE
NOTE: THE FUNCTION OF THE VALVE IS FIELD CONVERTIBLE
(G1/4) .125 DEEP(3.2) WHEN ORDERING A 4 WAY, CGS-4232-NB1
.34 THE PLUG IS IN POSITION “4” (AS SHOWN)
(8.6) .78 4 3 WHEN ORDERING A 3-WAY, CGS-3232-NB1
(19.8)
C THE PLUG IS IN POSITION “3”
1.26 EB BECOMES VENT WHEN USEN AS A 3-WAY
(32)
B A
MANUAL OVERRIDE .47
(Push-Type)
TOP VIEW (12) .47
(12)
.58 .58
1/4” NPT (G1/4)
(14.7) (14.7) BOTTOM VIEW B VENT PORT
.57
.74 (18.8) (14.5)
.26 (6.6)
.34 (8.6)
.62 (15.7) VENT
1.57 C 50
(39.9) .88
.63
.75 (19.1) (22.2)
.35 (8.9) (18)
.32 (8.1)
1/4” NPT (G1/4) .25 (6.4) .63 .88
(18) (22.2)
A B A
.47 .47
1/4” NPT (G1/4)
SIDE VIEW (CGS) INLET PORT
(12) (12)
1.47 1.03
(37.3) (26.2)
NOTES :
Dimensions show 1/4NPT body markings, G1/4 body markings
1/4” NPT (G1/4)
are: (1) = in; (4) = A; (2) = B; (5) = EA; (3) = EB.
A B Optons -PC is shown for reference.
SIDE VIEW (CGG/CXX)
Solenoid Option
A B A B A B
0.44 2.31 0.52 2.31 .73 2.39
(11.2) (58.7) (13.2) (58.7) (18.4) (60.7)
Solenoid Options
Valve
A B C A B C A B C A B C
3.71 1.31 .885 3.71 1.31 1.04 3.79 1.31 1.45 3.53 1.31 1.15
(94.2) (38.3) (22.5) (94.2) (33.3) (26.4) (96.3) (33.3) (36.8) (89.7) (33.3) (29.2)
4.21 3.71 .885 4.21 3.71 1.04 4.29 3.79 1.45 4.03 3.53 1.15
(106.9) (94.2) (22.5) (106.9) (94.2) (26.4) (109.0) (96.3) (36.8) (102.4) (89.7) (29.2)
7
DIRECT MOUNT ACTUATOR VALVES
SERIES C316 NAMUR
Stainless Steel 3 or 4-Way Solenoid Valves
General Description
designed to mount directly to any NAMUR actuator, thus reducing actuator response time and space. Installed costs are also lower
*Operating
Valve Hazardous Service
Pressure Range
Pneumatic Service
Single Solenoid-
Spring Return 25 to 150 psi (1.8 to 10.3 bar) 1.3 lbs (590 gms) 1.6 lbs (725 gms) 2.5 lbs (1130 gms)
Double Solenoid 15 to 150 psi (1 to 10.3 bar) 1.9 lbs (860 gms) 2.6 lbs (1180 gms) 4.3 lbs (1950 gms)
* .
5/2
3/2
*All valves include O ring interface seals and #10-24 mounting screws. For #10-32 screws
change NE1 to NE2. For M5 screws change NE1 to NE3.
Class I, Div 2 (A & B); Class I Div 1 (C & D); Class II Div 1 (E, F & G) 5.6/7.2
1/2” NPT conduit entry, Basic standard -XX Carbon Steel, Electroless nickel plated 1.8/1/8
with Low power 1.8W coil -LB-XX Carbon Steel, Electroless nickel plated 5.6/7.2
with potted coil -PC-XX Carbon Steel, Electroless nickel plated 5.6/7.2
with Stainless housing coil housing -ST-XX Stainless Steel
Flameproof (d) - ATEX IECEx
EEx II 2 G IIB + H2 T3 T6*
Ex d Ex d IIB T3 to T6 Gb 12VDC (D012)
H M20 x 1.5 conduit entry, Basic standard -XN Carbon Steel, Electroless nickel plated 24VDC (D024) 5.6/7.2
A with Low power 1.8W coil, T6 -LB-XN Carbon Steel, Electroless nickel plated 48VDC (D048) 1.8/1/8
Z with potted coil -PC-XN Carbon Steel, Electroless nickel plated 120V60 (A120) 110V50 (E110) 5.6/7.2
with Stainless steel coil housing -ST-XN Stainless Steel 240V60 (A240) 220V50 (E220) 5.6/7.2
A with Flamproof Junction Box -AJB-XN -XN w/Aluminum Epoxy Coated Box
R
- ATEX IECEx, CSA, INMETRO
D
EX II 2 G D
O Ex d e IIC T* Gb
U EX tb IIIC T* ºC Db
S EXd IIC DIP A21 T6 T4
Class I Div I Grp B, C & D
Class I Div II Grp E, F & G
with M20 x 1.5 conduit entry -XDBS † Stainless Steel w/ Junction Box 0.85,1.8 & 4
with 1/2” NPT conduit entry -XDBT † Stainless Steel w/ Junction Box 0.85,1.8 & 4
) - ATEX IECEx
EEX II 2 G Ex e mb II T5 & T6
EEX II 2 D Ex tD A21 IP66/IP67 T100ºC,T85ºC
Ex e mb II T5, T6 Gb
Ex tD A21 IP66/IP67 T100ºC,T85ºC Db
L M20 x 1.5 Conduit entry† -XMAA Engineered polymer NA/4.0
O with 6-12mm ø cable gland† -XMFA Engineered polymer NA/4.0
1/2” NPT conduit entry† -XMAF Engineered polymer NA/4.0
C with 9-16mm ø cable gland† -XMFF Engineered polymer NA/4.0
A FM/CSA
T Class I (Group A, B, C, D); Class II (Group E, F, G), CLASS III, DIV 1 ** NA/1.6
I With PG9 cable gland, mini -DIN type connector -HC-XISC Engineered polymer NA/1.6
with 1/2” NPT conduit entry -HCC-XISC Engineered polymer
O - ATEX
N II 2 G EEx ia IIC T4, to T6** Notes
With PG9 cable gland, mini -DIN type connector -HC-XISX6 Engineered polymer
* For high temperature coil add , -HT NA/1.6
with 1/2” NPT conduit entry -HCC-XISX6 Engineered polymer NA/1.6
(included in XMA_, XIF_)
II 2 G EEx ia IIC T4, to T6 ** 24 Volt DC Only
with M20 x 1.5 conduit entry -XIFA Engineered polymer NA/0.8
with 1/2” NPT conduit entry -XIFF Engineered polymer †For ordering information see “Miscellaneous” NA/0.8
column page 29.
M Manual Override, un-guarded push and hold (not available with all solenoid options) -ME
I Solenoid exhaust adapter, 1/8 NPT -H2
S Silencer/Dust Excluder for Solenoid Exhaust (not available -XISC or -XISX6) -L14
C
Typical CSG-4332-316-NE1-XMA-A120
Top View
1.63” Inches
(41.4) (mm) C316 NAMUR DIMENSIONS SOLENOID OPTIONS
GENERAL SERVICE HAZARDOUS SERVICE HAZARDOUS SERVICE
Valve Type (-XX, -XN, -XISC, -XISX6) (-XMA, -XIF)
Side View A B C A B C A B C
1.44” Inches Single solenoid, spring return Inches 5.62 1.44 2.33 5.67 1.44 2.33 6.59 2.56 4.27
(36.6) (mm) 3-Way or 4-Way (mm) (142.7) (36.6) (59.1) (144) (36.6) (59.1) (167.3) (65) (108.5)
Double solenoid Inches 8.70 1.44 2.33 8.79 1.44 2.33 10.6 2.56 4.27
3-Way or 4-Way (mm) (221) (36.6) (59.1) (233.2) (36.6) (59.1) (269.2) (65) (108.5)
Typical CGG-4332-316-NE1-XX-A120
Side View
For warranty information and/or any additional information with regards to installation,
operation and service warnings, please consult factory.
Typical CGG-4332-316-NE1-XMA_-A120
Side View
9
BODYPORTED VALVES
Operating
Size Pressure Range† s
Series Ordinary Hazardous
Pneumatic Service Service
15-115 psi 0.5 lbs. 0.8 lbs.
C5 (1-8 bar) (235 g) (363 g)
Single Solenoid/spring return
(2-position) 25-115 psi 0.7 lbs. 1.0 lbs.
C7 (1.7-8 bar) (300 g) (454 g)
† Pressure ranges may
10-115 psi 0.87 lbs. 1.2 lbs. change based on
C5 (0.7-8 bar) (395 g) (545 g) solenoid option.
Double Solenoid/detented
See page 6.
(2-position) 15-115 psi 1.0 lbs. 1.3 lbs. bar
C7 (1-8 bar) (454 g) (590 g) MPa =
10
EB EA
IN EB IN EA EB IN EA EB IN EA
1/8 NPT 0.75 (11) CSG-4222-†-(coil code) CGG-4222-†-(coil code) CXX-4223-†-(coil code) CXX-4224-†-(coil code)
C5
4-WAY G1/8” 0.75 (11) CSG-4282-†-(coil code) CGG-4282-†-(coil code) CXX-4283-†-(coil code) CXX-4284-†-(coil code)
5/2 & 5/3 1/4“ NPT 1.6 (23) CSG-4322-†-(coil code) CGG-4322-†-(coil code) CXX-4323-†-(coil code) CXX-4324-†-(coil code)
C7
G1/4 1.6 (23) CSG-4382-†-(coil code) CGG-4382-†-(coil code) CXX-4383-†-(coil code) CXX-4384-†-(coil code)
* 3-Way valve can be obtained by plugging one port of a 4-way. For 3-way NC plug port B (4); for 3-way NO plug port A (2).
10
Bodyported Series C5 & C7 Dimensions
I
.72
18.2
B
F G K
E
C
A
I
.72
18.2
F G
E K
C
A1
Basic Valve
Dimensions A A1 B C H J K
inch 5.03 7.92 1.25 0.88 3.71 1.69 0.38 0.63 2.11 1/8” NPT 2.47
C5
mm 127.7 201.2 31.8 22.4 94.2 42.8 9.5 15.9 53.5 G1/8 62.8
inch 5.65 8.55 1.50 1.06 4.02 2.00 0.47 0.75 2.23 1/4” NPT 2.52
C7
mm 143.6 217.1 38.1 27.0 102.2 50.8 11.8 19.1 56.7 G1/4 64.2
*(2) .144Ø THRU & .234Ø *(2) .172Ø THRU & .281Ø
C’BORE X.28 DEEP C’BORE X.38 DEEP
* (6-32SCREWS 1-1/4” LONG RECOMMENDED, PAS-0632-20) * (8-32SCREWS 1-1/2” LONG RECOMMENDED, PAS-0832-24)
1.25 1.50
.97 .25 31.8 1.12 38.1
24.6 6.4 28.4 .25
6.4
.31 .41
7.9 (2) .144 Ø THRU 10.3
(2) .172 Ø THRU
.63 .81
15.9 20.6
Bottom View
Bottom View .63
.81
.81 20.6
15.9
20.6
.63 .06
15.9 1.6
.06
1.6
1.06
.88 27.0
22.2
.06
.06
1.6
1.6
VALVES SUPPLIED WITH G THREADS HAVE PORTS MARKED AS FOLLOWS: IN=1, A=2, EA=3, B=4, EB=5
11
BODYPORTED VALVES
SERIES V Bodyported
3-Way & 4-Way Solenoid Valves
General Description
Versa Series V valves are full flow valves,
available in 1/8, 1/4, 3/8, 1/2, 3/4 and 1” satisfy.
NPT port sizes. Ports of 1/8 to
1/2 ISO 228 “G” threads Materials
are also available. Three- Valve body: forged brass
way designs are provided Actuating Caps: solenoid – forged brass
with 3 ports; four-way spring cap – diecast aluminum
designs have 5 ports. Each
Internal parts (wetted): rod brass
is available for 2-position or 3-position service. Standard size
Valve seals: NBR (nitrile), standard size O rings
O ring seals provide bubbletight sealing and ease of service.
Screws: zinc plated steel
Each valve is solenoid/pilot actuated, which enables the use of Solenoid parts: sleeve, plunger & spring – 304 & 430F and
physically small solenoids providing low power consumption, 302 stainless steel
and also assures a strong positive shifting force without fear of coils epoxy molded with 2 or 3 wire leads (Std.)
coil burn-out. A complete selection of electrical connections, coil cover (Std) – zinc chromate
plated steel
Operating
Port Ordinary Service Hazardous Service††
Pressure Range†
Size
Pneumatic
lbs. lbs. lbs. lbs.
1/8 or 1/4 40-175 psi 3.5 1.6 4.1 1.9 3.9 1.8 4.5 2.0
Single Solenoid/spring return 3/8 or 1/2 (2.8-12 bar) 5.3 2.4 6.6 3.0 5.7 2.6 7.0 3.2
(2-position) 50-175 psi
3/4 or 1 11.3 5.1 15.0 6.8 11.7 5.3 15.4 7.0
(3.5-12 bar)
1/8 or 1/4 4.9 2.2 5.5 2.5 5.8 2.6 6.3 2.9
Double Solenoid/momentary contact 20-175 psi
3/8 or 1/2 6.7 3.1 8.1 3.7 7.6 3.5 8.9 4.0
(2-position) (1.4-12 bar)
3/4 or 1 13.7 6.2 17.4 8.0 14.6 6.6 18.2 8.3
1/8 or 1/4 40-175 psi 5.8 2.7 6.3 2.9 6.7 3.1 7.1 3.2
Double Solenoid/spring centered 3/8 or 1/2 (2.8-12 bar) 7.6 5.0 8.9 4.0 8.5 5.4 9.7 4.4
(3-position) 50-175 psi
3/4 or 1 17.5 7.9 21.2 9.6 18.3 8.3 22.0 10.0
(3.5-12 bar)
†Pressure ranges may change based on solenoid option. See page 27/29. MPa = bar
10
12
Series V Bodyported Valve Product Number Selector
BASIC VALVE NUMBER
Port Double Solenoid/
Function Flow Single Solenoid/Spring Double Solenoid/Spring Centered 3-position
Size Momentary Contact
(NPT)* CV (Kv) Return 2-position 2-position Blocked Center Exhaust Ports Open
P
P T P T
ACT.
1/8” 1.4 (20.3) VSG-4222-U-(coil code) VGG-4222-U-(coil code) VXX-4223-U-(coil code) VXX-4224-U-(coil code)
1/4” 1.8 (26.1) VSG-4322-U-(coil code) VGG-4322-U-(coil code) VXX-4323-U-(coil code) VXX-4324-U-(coil code)
4-way, 3/8” 3.4 (49.3) VSG-4422-U-(coil code) VGG-4422-U-(coil code) VXX-4423-U-(coil code) VXX-4424-U-(coil code)
1/2” 4.0 (58.0) VSG-4522-U-(coil code) VGG-4522-U-(coil code) VXX-4523-U-(coil code) VXX-4524-U-(coil code)
3/4” 9.7 (140.6) VSG-4622-U-(coil code) VGG-4622-U-(coil code) VXX-4623-U-(coil code) VXX-4624-U-(coil code)
5/2 & 5/3 1” 11.1 (161.0) VSG-4722-U-(coil code) VGG-4722-U-(coil code) VXX-4723-U-(coil code) VXX-4724-U-(coil code)
B A B A
B A B A
P P
P T P T
For coil code see page 27 for ordinary location or page 29 for hazardous location.
Coil & Coil Housing - nonhazardous location Solenoid Operator - nonhazardous location
}
Manual Override -
-PC
-XX
Seals -XN
-AJB-PS-XN
(page 28/29)
-XIFA, E, F
Voltage (coil code) -Nonhazardous location operators - -HC-XISC, -HCC-XISC
(page 26/27). Hazardous location operators - (page 28/29). -HC-XISX6, -HCC-XISX6
For other coil voltages consult factory. -XMAA, E, F, G
-XMFA, E, F, G
Misc - nonhazardous & hazardous
13
BODYPORTED VALVES
BRASS CONSTRUCTION
F C Of
Valve 1/8 -1/4 2 163 56 1 34 44 1 165 33 2132 17 5164 20 1 1932 40 .256 6.5
E 3/8 -1/2 3 34 95 2 78 73 2 51 1 25 1 18 29 2 14 57 .328 8
IN EX
D1 MAX D1 MAX
3 3 (19 mm)
4 (19 mm) 4
1 NPT CONDUIT
1 2
2 NPT CONDUIT CONNECTION X CONNECTION X
B a s i c Va lve
Di me n sio n s A B C C* D1 D E F H J K K* X
NPT or G in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/8 - 1/4 2 163 56 1 327 31 2 323 53 3 76 2 12 64 2 51 1 25 1 12 38 2 1932 66 1316 21 1 329 33 2163 56 31316 97
3/8 - 1/2 3 34 95 1 327 31 2 323 53 3 76 2 78 73 2 34 70 1 38 35 1 1611 43 2 2132 67 7
8 22 1 329 33 2163 56 3 78 98
D1 MAX D1 MAX
3 3
4 (19 mm) 1 4 (19 mm)
8 NPT
EXPILOT PORT
3 1 & 11
FOR 4 4
ONLY
1 NPT CONDUIT CONNECTION X MAX 1 1
2 8 NPT 2 NPT CONDUIT CONNECTION X
EXPILOT PORT
FOR
F
H 138 (35 mm) H 138 (35 mm)
1 1
8 THRU 2 J J
ONLY MANUAL MANUAL
K 13
OVERRIDE 13
K/K* 13 OVERRIDE
32 (10 mm) E 32 K/K* 32 E
(OPTIONAL) (10 mm) (OPTIONAL)
B A C C/C* A (10 mm)
D C/C* D
B a s i c Va lve
Di me n sio n sA B C C* D1 D E F H J K K* X
NPT or G in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/8 - 1/4 3 12 89 1 327 31 2 323 53 3 76 2 12 64 2 51 1 25 1 12 38 2 1932 66 1316 21 1 329 33 2163 56 31316 97
3/8 - 1/2 5 34 146 1 327 31 2 323 53 3 76 2 78 73 2 34 70 1 38 35 1 1611 43 2 2132 67 7
8 22 1 329 33 2163 56 3 78 98
3/4 - 1 8 12 216 2161 52 2 51 3 15
32 88 3 38 86 3 34 95 1 78 48 2167 62 3 29
32 99 1 14 32 1 25 2 12 64 5 325 131
†Dimensions shown are for basic valve as listed on previous page. Some options may change the dimensions, for which consult factory.
14
BODYPORTED VALVES
} }
----------- -LB-XX; -LB-XN
-XDBS* or T* ---------- 60.7
-XX -XX -XX Non Hazard.
-XMAA, E, F or G
-XMFA, E, F or G } Encapsulation (page 28/29) } ----------
----------
Hazard.
MISCELLA Hazard.
-
-HT Class H coil (page 31) -HT
-M,-M5R,-MAE Manual Override (page 31) -----------
-E14 Silencer/Dust Excluder for Solenoid Exhaust -L14 15
*For ordering information See “Miscellaneous” column page 29.
BODYPORTED VALVES
plunger that provides bubbletight performance with long, trouble- Screws: stainless steel
Solenoid internal parts: 304, 430F & 302 stainless steel
smallest package. Stainless steel bodies, actuating caps and Coil/solenoid housing: per solenoid option selected
internal parts allow use in the most aggressive environments.
The C316 Series is available as 4-Way, for double acting devices,
or 3-Way for spring return devices. The 3-Way function can be
*Weights shown are for 3-Way valves. For 4-Way add 0.1 lbs (45 gms).
Porting Sizes Flow Rate
Inlet cylinder & exhaust: 1/4 NPT Cv = 2.0 (Kv = 29.3)
Installation, Filtration and Lubrication Options
Valves have no limit on mounting orientation. See page 17
Lubrication not required
Ambient & media temperature range -5°F to 200°F (-20°to 93°C)
16
Series C316 Bodyported Solenoid Options
Voltages (Coil Codes) NOMINAL
Solenoid Housing All options available in all voltages,
COIL POWER
Detail Material
voltages.
G General Purpose
E 1/2” NPT conduit, NEMA 1, 2, & 3* None Carbon Steel, Painted 6.0/7.0
N 1/2” NPT conduit, watertight, NEMA 4 & 4X** -PC Carbon Steel, Electroless nickel plated 6.0/7.0
E Cord grip PG9 mini-DIN type connector, NEMA 4 -HC Engineered polymer 6.5/10.5
R 1/2” NPT conduit, mini-DIN type connector, NEMA 4 -HCC Engineered polymer 6.5/10.5
A
L * For high temperature coil include -HT
Hazardous Location UL/CSA (NEMA 7& 9)
Class I, Div 2 (A & B); Class I Div 1 (C & D); Class II Div 1 (E, F & G) 5.6/7.2
1/2” NPT conduit entry, Basic standard -XX Carbon Steel, Electroless nickel plated 1.8/1/8
with Low power 1.8W coil -LB-XX Carbon Steel, Electroless nickel plated 5.6/7.2
with potted coil -PC-XX Carbon Steel, Electroless nickel plated 5.6/7.2
with Stainless housing coil housing -ST-XX Stainless Steel
Flameproof (d) - ATEX IECEx
EEx II 2 G IIB + H2 T3 T6*
Ex d Ex d IIB T3 to T6 Gb 12VDC (D012)
H M20 x 1.5 conduit entry, Basic standard -XN Carbon Steel, Electroless nickel plated 24VDC (D024) 5.6/7.2
A with Low power 1.8W coil, T6 -LB-XN Carbon Steel, Electroless nickel plated 48VDC (D048) 1.8/1/8
with potted coil -PC-XN Carbon Steel, Electroless nickel plated 120V60 (A120) 110V50 (E110) 5.6/7.2
Z with Stainless steel coil housing -ST-XN Stainless Steel 220V50 (E220) 240V60 (A240) 5.6/7.2
A with Flamproof Junction Box -AJB-XN -XN w/Aluminum Epoxy Coated Box
R
D - ATEX IECEx, CSA, INMETRO
O EX II 2 G D
Ex d e IIC T* Gb
U EX tb IIIC T* ºC Db
S EXd IIC DIP A21 T6 T4
Class I Div I Grp B, C & D
Class I Div II Grp E, F & G
with M20 x 1.5 conduit entry -XDBS† Stainless Steel w/ Junction Box 0.85,1.8 & 4
with 1/2” NPT conduit entry -XDBT† Stainless Steel w/ Junction Box 0.85,1.8 & 4
) - ATEX IECEx
EEX II 2 G Ex e mb II T5 & T6
EEX II 2 D Ex tD A21 IP66/IP67 T100ºC,T85ºC
Ex e mb II T5, T6 Gb
Ex tD A21 IP66/IP67 T100ºC,T85ºC Db
L M20 x 1.5 Conduit entry† -XMAA Engineered polymer NA/4.0
O with 6-12mm ø cable gland† -XMFA Engineered polymer NA/4.0
1/2” NPT conduit entry† -XMAF Engineered polymer NA/4.0
C with 9-16mm ø cable gland† -XMFF Engineered polymer NA/4.0
A FM/CSA
T Class I (Group A, B, C, D); Class II (Group E, F, G), CLASS III, DIV 1 ** NA/1.6
I With PG9 cable gland, mini -DIN type connector -HC-XISC Engineered polymer NA/1.6
with 1/2” NPT conduit entry -HCC-XISC Engineered polymer Notes
O Intrinsically Safe (ia) - ATEX * For high temperature coil add , -HT
N II 2 G EEx ia IIC T4, to T6**
With PG9 cable gland, mini -DIN type connector -HC-XISX6 Engineered polymer (included in XMA_, XIF_) NA/1.6
with 1/2” NPT conduit entry -HCC-XISX6 Engineered polymer NA/1.6
** 24 Volt DC Only
Intrinsically Safe (ia) - ATEX
II 2 G EEx ia IIC T4, to T6 †For ordering information see “Miscellaneous”
with M20 x 1.5 conduit entry -XIFA Engineered polymer column page 29. NA/0.8
with 1/2” NPT conduit entry -XIFF Engineered polymer NA/0.8
M Manual Override, un-guarded push and hold (not available with all solenoid options) -ME
I Solenoid exhaust adapter, 1/8 NPT -H2
S Silencer/Dust Excluder for Solenoid Exhaust (not available -XISC or -XISX6) -L14
C
Typical CSG-4322-316-XX-A120
Top View
Dimensions
1.62
(41.1)
Dimensions
EA IN EA
5 1 3
SOLENOID OPTIONS
4-Way Single Solenoid, Inches 5.81 1.04 2.13 5.91 1.44 2.30 6.81 2.56 4.13
Spring Return † (mm) (147.7) (26.4) (54.2) (150.2) (36.6) (58.5) (173.0) (65) (104.8) Typical CGG-4322-316-XX-A120
Side View
3-Way Double Solenoid, Inches 8.33 1.04 2.13 8.53 1.44 2.30 10.33 2.56 4.13
Detented † (mm) (211.6) (26.4) (54.2) (216.8) (36.6) (58.5) (262.4) (65) (104.8)
4-Way Double Solenoid, Inches 8.83 1.04 2.13 9.03 1.44 2.30 10.83 2.56 4.13
Detented † (mm) (221.3) (26.4) (54.2) (229.5) (36.6) (58.5) (275.0) (65) (104.8)
3-Way Double Solenoid, Inches 6.41 1.04 2.34 6.51 1.44 2.34 7.41 2.56 4.13
Latching* (mm) (162.9) (26.4) (59.4) (165.5) (36.6) (59.4) (188.2) (65) (104.8) Typical CGG-4322-316-XMA_-A120
Side View
* Add 0.5” (12.7 mm) to “A” dimension for 4-Way Latch Valve. † For dimensions –XDA_ & XDB_ consult factory
Typical CAG-3321-316-356BN-XX-A120
Side View
17
BODYPORTED VALVES
Operating
Port Size Pressure Range† Ordinary Service Hazardous Service††
Pneumatic
lbs. lbs. lbs. lbs.
Single Solenoid/spring return 1/4” & 3/8” NPT 40-175 psi 2.5 1.2 2.8 1.3 2.7 1.2 3.2 1.5
(2-position) 1/2” NPT (2.8-12 bar) 3.4 1.6 3.2 1.5 3.6 1.6 3.6 1.6
Double Solenoid/momentary contact 1/4” & 3/8” NPT 20-175 psi 3.4 1.6 3.9 1.8 3.8 1.7 4.3 2.0
(2-position) 1/2” NPT (1.4-12 bar) 4.3 2.0 4.3 2.0 4.7 2.1 4.7 2.1
Double Solenoid/spring centered 1/4” & 3/8” NPT 40-175 psi 3.5 1.6 4.0 1.8 3.9 1.8 4.4 2.0
(3-position) 1/2” NPT (2.8-12 bar) 5.0 2.3 5.0 2.3 5.4 2.5 5.4 2.5
†
Pressure range may change based on solenoid options. See page 27/29.
MPa = bar
10
††
consult factory.
18
Series V316 Bodyported Valve
Product Number Selector
Port
Function Size Momentary Contact
* CV Return, 2-position 2-position
* Add coil code to valve number (ordinary page 27, hazardous page 29).
Coil & Coil Housing nonhazardous location Solenoid Operator nonhazardous location
none: Std coil & housing, (page 30) none: Std coil & housing, (page 26/27)
-HT: Class H coil, (page 31) -HC or -HCC: DIN style coil and connector, (page 26/27)
-HC or -HCC: DIN style coil & connector, (page 30)
-PC: Potted coil, (page 30) Solenoid Operator - hazardous location
Manual Override
}
-ST: Stainless steel coil cover (page 30)
-LB-XX;-LB-XN Low power (1.8 W) operator, (page 28/29)
-ME: Manual override (page 31) -XX
-PC-XX; -PC-XN
Misc -XN
-AJB-PS-XN
-L14: Silencer/Dust Excluder for -XDAS,T (page 28/29)
Solenoid Exhaust (not available -XIFA, F
for -XISC or -XISX6) -HC-XISC, -HCC-XISC
-HC-XISX6, -HCC-XISX6
-XMAA, E, F, G
-XMFA, E, F, G
19
BODYPORTED VALVES
F C Of
Valve
2 163 56 134 44 33 21
32 17 64 20 119
32 40 .256 6.5
E 1 51
IN EX
3/8 2 3
16 56 1 23
32 44 1 4 32 21
32 17 64 20 119
32 40 .256 6.5
5 51
C 1/2 4 102 3 5
16 84 116 33 21
32 17 64 20 119
32 40 .256 6.5
B
1 1
8 ADAPTER (OPTIONAL - SEE NOTE BELOW) 8 ADAPTER (OPTIONAL - SEE NOTE BELOW)
D1 MAX D1 MAX
9 (15 mm) 1
9
16 (19 mm) 16 8 NPT
EXPILOT PORT
EXPILOT PORT 3 1 & 11
FOR 4 4
ONLY
1 NPT CONDUIT
1 2
2 NPT CONDUIT CONNECTION X CONNECTION X
H 15 (24 mm)
16 H 1 38 (35 mm)
F
J J
MANUAL
K/K* K/K* 13 OVERRIDE
E 32 E (OPTIONAL)
B A C D C/C* A C/C* (10 mm)
D
BASIC VALVE
DIMENSIONS A B C C* D1 D E F H J X
NPT in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4-3/8 2163 56 1 325 29 158 41 2169 65 2 12 64 2 51 1 25 1 12 38 2 78 73 3
4 19 3 43 95
1/2 4 102 1 325 29 158 41 2169 65 2 12 64 2 12 64 1 14 32 1 12 38 2 78 73
3
4 19 3 43 95
H Mounting C C
Holes (3) B
D1 MAX D1 MAX
9
16 (15 mm)
9
16 (15 mm)
BASIC VALVE
DIMENSIONS A B C C* D1 D E F H J X
NPT in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4-3/8 3 12 89 1 325 29 1 58 41 2 169 65 2 12 64 2 51 1 25 112 38 2 78 73 3
4 19 3 34 95
1/2 4 102 1 325 29 1 58 41 2 169 65 2 12 64 2 12 64 114 32 112 38 2 78 73 3
4 19 3 34 95
†Dimensions shown are for basic valve as listed on previous page. Some options may change the dimensions, for which consult factory.
20
LOCKOUT VALVES
BRASS OR STAINLESS STEEL
3-Way NC
Solenoid Operated/Spring Return
Lockout Valves
General Description
Versa 3-way normally closed Lockout Valves function the same as a solenoid operated-spring return valve,
except that a means is provided to allow the valve to be physically locked with a padlock or hasp with
padlock in order to prevent accidental actuation. Two types of lockout are available: one pro-
vides the ability for locking the valve in the de-energized position whereby the inlet is blocked
and the exhaust is open; the other type provides the ability for locking in either the de-energized
or energized position.
Types Available
Series V
Media: Pneumatic Service Pneumatic Service
Pressure: (minimum depends 40 or 50 to 175 psi 40 to 175 psi
on valve size) (2.8 or 3.5 - 12 bar) (2.8 - 12 bar)
Construction Materials: Forged & machined brass; Investment cast & machined 316
NBR (nitrile) O ring seals
Lockout Valves
Product Number Selector
Series V
PORT FLOW LOCKOUT IN LOCKOUT IN LOCKOUT IN LOCKOUT IN OPERATING
FUNCTION
SIZE Cv (kv) EXHAUST POSITION EITHER POSITION EXHAUST POSITION EITHER POSITION PRESSURE
* Add coil code to valve number (ordinary page 27; hazardous page 29).
model number
Options Installation, Filtration and Lubrication
Options available for Series V Lockout Valve are the same Valves have no limitations on mounting orientation.
as listed on page 13.
Options available for Series V316 Lockout Valve are the ISO, ASTM viscosity grade 32 recommended.
same as listed on page 19. Ambient temperature range -10°F (-23°C) to 200°F (95°C).
21
SPECIAL PURPOSE DUAL SOLENOID VALVES
BRASS OR
A dual solenoid valve with a hand lever. The design concept is to provide
the functionality of a, dual coil, 2-position valve with the addition of manual
control or any other actuator. The valve operates as standard 2-position
requiring only momentary electrical contact to shift valve. Various
manual actuators are available. The lever shown is a -”L” type which can
be manually set in either offset position when the solenoid valve is de-
energized.
Redundant Solenoid
When parallel electronic control circuits are utilized in a system, if a complete control
circuit fails or requires maintenance, the parallel circuit will keep the system
running. In a parallel circuit Versa’s Redundant Valve functions the same as
a solenoid operated-spring return valve, except that it has two solenoids
(one for each of the parallel circuits) rather than one solenoid. Either or
both of these solenoids will shift and maintain the controlled device in
the shifted position. Both solenoids must be de-energized to return the
controlled device to the un-shifted position. The use of one Redundant
Valve can replace multiple valves and components to accomplish the
same function. This function can be considered as a (2oo2).
1oo2,
While the Shut off Valve looks similar to the Redundant Solenoid
Valve (shown above) the internal pilot circuit is different. The -SOV
option provides a series pilot control circuit that requires both coils, a
primary and a secondary, to be energized in order for the valve to shift.
Conversely if the electrical signal to either coil is removed the valve will
return to the de-energized position. This function can be considered as
a (1oo2). Where various control devices (e.g., temperature, pressure
switches) could be wired in series with each coil. The actuation of any
one of these devices, attached to either coil, would interrupt the signal to
the coil and cause the valve to shift to the de-energized position.
B
A
B
A
B
A
EA
EB
EA
EB
EA
EB
IN
IN
IN
Construction Material: Forged & machined brass; Investment cast & machined
NBR (nitrile) O ring seals
3-way, normally closed 3-way, normally closed
4-way, 2 position 4-way, 2 position
1/8” NPT or G1/8 (Cv=1.4,Kv=20.3) 1/4” NPT (Cv=1.8,Kv=26
1/4” NPT or G1/4 (Cv=1.8,Kv=26.1) 3/8” NPT (Cv=2.0,Kv=29)
3/8” NPT or G3/8 (Cv=3.4,Kv=49.3) 1/2” NPT (Cv=5.5,Kv=80)
1/2” NPT or G1/2 (Cv=4.0,Kv=58.0)
Solenoid/pilot-spring return Solenoid/pilot-spring return
Actuation:
(2 solenoids per valve), (2 solenoids per valve),
for either ordinary or hazardous service. for either ordinary or hazardous service.
22
SPECIAL PURPOSE DUAL SOLENOID VALVES
How to specify SPECIAL PURPOSE DUAL SOLENOID VALVES
V SA - 3 5 2 1 - 316 - RS (OPTIONS)
V = V Series brass or stainless steel.
See page 12 for Series V,
page 18 for Series V316.
3 = Three-way
4 = Four-way
2 = 1/8”NPT (Series V**)
3 = 1/4”NPT (Series V**) or V316)
4 = 3/8”NPT (Series V**) or V316)
5 = 1/2”NPT (Series V**) or V316)
1 = 3-way NC
2 = 3-way NO, 4-way/2-position
3 = 4-way/3-position (blocked center)
4 = 4-way/3-position (exhaust ports open in center)
-RS
SPECIAL PURPOSE DUAL SOLENOID VALVES SUFFIX -SOV
-PPG
OPTIONS
**
Installation, Filtration And Lubrication
Dimensions
A 24"(610mm) LEADS
24°
Ø .33 (3 MOUNTING
8.3 HOLES)
A D
24"(610mm) LEADS (TYP) 0.57 TYP
24"(610mm) GROUND LEAD 14.6 Ø .33
8.3
(3 MOUNTING HOLES)
GREEN (TYP) 1/2" NPT
1/2" NPT CONDUIT
(5 PORTS) CONNECTION
B
EX EX
C
IN
D
C
SIZE A B† C† D SIZE A B† C† D E
R 3 1/8 & 1/4 in 7.2 3.45 3.66 2 3 1/8 & 5.49 3.80 1.30 2.0 6.37
W mm 183 88 93 51 W 1/4 139 96.6 96.6 50.8 162
S
A in 8.78 3.43 4.18 2.76 A 3/8 & 7.05 4.35 4.62 2.75 6.45
3/8 & 1/2 P
or Y mm 223 87.2 106.1 70 Y 1/2 179 110.4 117.4 69.9 163.9
P
4 in 8.50 3.45 3.66 2 4 1/8 & 6.81 3.80 4.62 2.0 6.37
S 1/8 & 1/4 G
W mm 216 88 93 51 W 1/4 173 96.6 117.4 50.8 161.9
O
A in 10.75 3.50 4.02 2.76 A 3/8 & 9.05 4.35 4.62 2.75 6.45
V Y 3/8 & 1/2 mm 273 89 102 70 Y 1/2 230 110.4 117.4 69.9 163.9
†
23
LATCHING/MANUAL RESET VALVES
BRASS OR
General Description
Latching valves are particularly suited to applications where it is desirable or mandatory
to manually reset or restart a system. A typical application could involve the emergency
shutdown of automatically monitored process operations. Loss or interruption of the
control signal to the valve actuator causes the valve to shift, latch and shut-down
a process step. When the signal is restored the valve remains in the latched position
until the operator manually unlatches it and allows the process step to resume. Positive
latching in such an application is vitally important since many process operations are sequential
and one step must not be started until the one ahead of it has started.
This example is only one of many which can be accommodated through the use of Versa’s Latching Valves. A wide
range of functional types, port sizes, actuators, and latching arrangements provide the engineer with a complete choice
of valving to suit his particular needs.
Actuation Solenoid/pilot for either ordinary service or Solenoid/pilot for either ordinary service or
hazardous service. hazardous service.
NPT or any Series V316 valve body up to 1/2” NPT, as indicated for the type of latching/reset device
required. The actuator on the opposite end of the valve body would be a solenoid/pilot device.
ET
S
U LL
RE
TO
P
ET
ET S
U LL
S
RE
U LL
ET
RE
S
U LL
TO
P
RE
TO
P
TO
P
SET
O
U LL
RE
T
P
O
T
P
24
How to specify LATCHING/RESET VALVES
V AG - 3 5 2 1 - 181B - (OPTIONS)
V = Pneumatic service: nominal 20 to 175 psi
3 = Three-way
4 = Four-way
1 = 3-way NC
2 = 3-way NO, 4-way/2-position
OPTIONS
25
Solenoid/Pilot actuated valves are available with a variety of different solenoids for both nonhazardous and hazardous
locations. Basic details of actuators for nonhazardous locations are listed below. Details for hazardous location actuators
are listed on pages 28/29. For additional data consult factory. Product numbers and other details may be found on the
26
Com-
plete product numbers require, when applicable, a
coil code that represents the desired coil current,
frequency and voltage. The coil code takes the
form shown below, with ratings and voltage substi-
tuted as required
* ###
Rating Code Voltage
A= 60Hz frequency (indicated by three digits;
D= Direct Current (DC) as example, 24 volts = 024,
E= 50 Hz frequency 120 volts = 120).
All usual 50 Hz & 60 Hz AC (Series V=8.7W; Class F epoxy molded coil (155°C) with Steel Electroless nickel plated cover with
Series E=8.7W; Series V316 & E5=6W). 2 leads 24” (61 cm). Continuous duty. 1/2 NPT conduit entry.
All usual DC (Series V=9.5W; For watertight (NEMA 4 & 4X) potted coil
& Electroless nickel plated steel cover
Series E=9.5W; Series V316 & E5=7W). with 1/2 NPT conduit entry option: (-PC)
For Mini DIN connector with PG9 cord
grip, NEMA 4, IP65 per IEC 529 option:
(-HC)
For Mini DIN connector with 1/2 NPT
conduit entry, NEMA 4, IP65 per IEC 529
option: (-HCC)
24V60, 120V60, 240V60 (8.5W, Class F epoxy molded coil (155°C) with For Mini DIN connector with PG9 cord grip,
NEMA 4, IP65 per IEC 529 option: (-HC)
except 6W with NAMUR Series E5) 3 spade terminals. Continuous duty.
24V50, 110V50, 220V50, 240V50 (8.5W, For Mini DIN connector with 1/2 NPT
except 6W with NAMUR Series E5) conduit entry, NEMA 4, IP65 per IEC 529
option: (-HCC)
12VDC, 24VDC, 48VDC (10.5W,
except 7W with NAMUR Series E5) For integrally epoxy molded coil and
1/2” NPT conduit connection with 2 wire
leads 24” (61cm), NEMA 4 option: (-228L)
12VDC, 24VDC, 48 VDC (7W; Class F epoxy molded coil (155°C) Painted carbon steel cover with 1/2 NPT
with 2 leads 24” (61 cm). Continuous conduit entry.
with Mini DIN 10.5W) duty.
110V50, 220V50 (6W; with For watertight (NEMA 4 & 4X potted coil &
Electroless nickel plated steel cover option:
Mini DIN 6.5W) (-PC).
120V60, 240V60 (6W; with
For Mini DIN connector (NEMA 4) with PG9
Mini DIN 6.5W)
cord grip option: (-HC)
27
OPTIONS -
Solenoid/Pilot actuated valves are available with a variety of different solenoids for both nonhazardous and hazardous locations.
Basic details of actuators for hazardous locations are listed below. Details for nonhazardous location actuators are listed on pages
26/27. For additional data consult factory. Product numbers and other details may be found on the appropriate pages for each
Protection Ingress
Protection
None or
General Purpose Indoor & Outdoor CSA NEMA 1,2,3
-U
-HC NEMA 4;
General Purpose Indoor & Outdoor CSA
-HCC (Shown) IP65
-XX
Class I Groups C & D,
Hazardous Locations Class I, Div 2, Groups A, B, C & D; UL - CSA NEMA 7 & 9
Class II, Div 2, Groups E, F & G; T3C;
-LB-XX
-XN
Ex d IIB+H2 T3 to T6 Gb IECEx
(d) Flameproof P66 & IP68
II 2 G Ex d IIB+H2 T3 to T6 IECEx ATEX
-LB-XN
EX II 2 G D ATEX
Ex d e IIC T* Gb ATEX - IECEx -INMETRO
EX tb IIIC T* ºC Db
-XDBS* (d) Flameproof IP66, IP67,
(e) Increased Safety CI Div I Grp B, C & D CSA & IP67
-XDBT*
CI Div II Grp E, F & G
EX d IIC DIP A21 T6 T4
For ordering information
see “Miscellaneous”
column page 29
-XMAA
-XMAE
-XMAF Ex e mb II T5, T6 Gb
IECEx
-XMAG (mb) Encapsulation Ex tD A21 T100ºC, T85ºC Db
(e) Increased Safety IP66 & IP67
-XMFA (tD) Tight Dust II 2 G Ex e mb II T5, T6
-XMFE ATEX
II 2D Ex tD A21 T100ºC, T85ºC
-XMFF
-XMFG
IP65
Class I, Groups (A, B, C & D)
-XISC Intrinsic Safe Class II, Groups (E, F, &G) Factory Mutual CSA
Class III
28
PRODUCT NUMBER COIL CODES: Complete product numbers
require, when applicable, a coil code that represents the desired
coil current type, frequency and voltage. The coil code takes
the form shown below, with ratings and voltage substituted as
required.
24V60, 120V60, 240V60 (8.5W) Class F epoxy molded coil (155ºC), with 3 Page 5.1
24V50, 110V50, 220V50 (8.5W) spade terminals and mini DIN socket with
12VDC, 24VDC, 48VDC (10.5W) PG9 cable gland. Continuous duty.
Voltage
Miscellaneous
All usual 50 Hz & 60 Hz AC (5.6W) Steel chromate coated coil housing with 1/2 NPT conduit entry.
All usual DC (7.2W) For stainless steel (182FM) coil housing add: (-ST)
Steel chromate coated coil housing
12V60, 24V60, 48V60, 120V60, 240V60 with 1/2 NPT conduit entry.
(1.8W) For stainless steel (182FM ) coil housing add: (-ST)
6VDC, 12VDC, 24VDC, 48VDC (1.8W) Maximum pilot pressure 120 psi (8 bar).
1.8W nominal power.
Class F epoxy molded coil (155ºC).
Steel chromate coated coil housing
Continuous duty.
All usual 50 Hz & 60 Hz AC (5.6W) with M20 x 1.5 conduit entry.
3 leads 24” (60 cm).
All usual DC (7.2W) Ground terminal on cover.
For stainless steel (182FM) coil housing add: (-ST)
Steel chromate coated coil housing
with M20 x 1.5 conduit entry.
12V60, 24V60, 48V60, 120V60, 240V60
Ground terminal on cover.
(1.8W)
For stainless steel (182FM) coil housing add: (-ST)
6VDC, 12VDC, 24VDC, 48VDC (1.8W)
Maximum pilot pressure 120 psi (8 bar)
1.8W nominal power.
Stainless steel coil housing with
internal Junction Box. Internal and M 20 Connection ½” Connection
24VDC (D024) external ground screw.
120V60 (A120) 110V50 (E110) No Diode Diode No Diode Diode
230V50 (E230) Epoxy molded coils rated for continuous Standard (vent to atmosphere) XDBS1 XDBS5 XDBT1 XDBT5
duty, Class H – 180°C.
1.8 Watt standard, for lower watt contact 1/8” Adapter (-H2E) XDBS2 XDBS6 XDBT2 XDBT6
factory. 1/4” Adapter (-H2) XDBS3 XDBS7 XDBT3 XDBT7
Dust Nut (-L14) XDBS4 XDBS8 XDBT4 XDBT8
24VDC (4W)
(Consult factory for other voltage op- Thick wall epoxy coil housing with integral
surge suppression, potted within housing. junction box. Internal ground terminal.
tions)
M20 x 1.5 conduit entry: (-XMAA), (-XMFA),
Cable gland for 6-12 mm ø cable: (-XMAE), (-XMFE)
24VDC 1/2 NPT conduit entry with adapter: (-XMAF), (-XMFF)
Continuous duty. Coil & Power Controller
(10W inrush, 2.6W holding) Cable gland for 9-16 mm ø cable: (-XMAG), (-XMFG)
potted with in housing.
(Consult factory for other voltages)
29
OPTIONS AVAILABILITY CHART
Solenoid Options - Nonhazardous Location
VALVE SERIES
NAMUR NAMUR NAMUR
. V
1/2” NPT Conduit entry, NEMA 1,2,3 -C50 -C50 std -C50 std std std std std
1/2” NPT Conduit entry, Potted coil -PC -PC -PC -PC -PC -PC -PC -PC -PC
NEMA 4 & 4X, 11, 12, 13.
1/2” NPT Conduit Integrally Molded -228L -228L n/a -228L n/a n/a n/a n/a n/a
Coil & Conduit Entry, NEMA 4/IP65.
3 Spade Terminals, for use with std std n/a std n/a n/a n/a n/a n/a
mini DIN connector
Mini DIN Connector with PG9 cord grip, -HC -HC -HC -HC -HC -HC -HC -HC -HC
NEMA 4.
Mini DIN Connector with 1/2” NPT conduit -HCC -HCC -HCC -HCC -HCC -HCC -HCC -HCC -HCC
entry, NEMA 4.
1/2” NPT Conduit entry, NEMA 7 & 9, -XX -XX -XX -XX -XX -XX -XX -XX -XX
UL & CSA.
M20 x 1.5 Conduit entry, -XN -XN -XN -XN n/a -XN -XN -XN -XN
(d) Flameproof, IP66, T4, ATEX
Stainless steel (182 FM) coil cover for -XX -ST -ST -ST --ST n/a -ST -TR50-ST -ST --ST
Hazardous Location Options: -XN -ST -ST -ST -ST n/a -ST -ST -ST -ST
Potted Coil (female threaded conduit -XX -PC -PC -PC -PC n/a -PC -TR50-PC -PC -PC
connection) for Hazardous Location options,
NEMA 4X, 11, 12, 13: -XN -PC -PC -PC -PC n/a -PC -PC -PC -PC
Potted Coil (male threaded conduit n/a n/a n/a n/a -PS n/a -PS n/a n/a
connection) for-XX Hazardous
Location options, NEMA 4X, 11, 12, 13.
For -XN Hazardous Location option; -LB-XN -LB-XN -LB-XN -LB-XN n/a -LB-XN -LB-XN -LB-XN -LB-XN
T6, ATEX.
30
Solenoid Options - Hazardous Location Cont.
VALVES SERIES
(e) Increased Safety NAMUR NAMUR
V
(d) Flameproof
EX II 2 G D
Ex d e IIC T* Gb
EX tb IIIC T* ºC Db
EXd IIC DIP A21 T6 T4 n/a n/a -XDBS* n/a -XDBS* n/a -XDBS* -XDBS* -XDBS*
n/a n/a -XDBT* n/a -XDBT* n/a -XDBT* -XDBT* -XDBT*
CSA: CI Div I Grp B, C & D
CI Div II Grp E, F & G
(e) Increased Safety n/a n/a -XMAA n/a -XMAA n/a n/a -XMAA -XMAA
(m) Encapsulated n/a n/a n/a -XMAE n/a -XMAE -- -XMAE
(tD) Dust Tight n/a n/a -XMAF n/a -XMAF n/a -XMAF -XMAF -XMAF
Ex e Ex mb, Ex tD n/a n/a -- n/a -XMAG n/a -XMAG -- -XMAG
Ex e mb II T5, T6 Gb -
Ex tD A21 T100ºC, 85ºC n/a n/a -XMFA n/a XMFA n/a -XMFA -XMFA -XMFA
EEX n/a n/a -- n/a -XMFE n/a -XMFE -XMFE
II 2 G Ex e mb II T5, T6 n/a n/a -XMFF n/a -XMFF n/a -XMFF -XMFF -XMFF
Ex tD A21 T100ºC, 85ºC n/a n/a -- n/a -XMFG n/a -XMFG -- -XMFG
(ia) Intrinsic Safe n/a n/a -XIFA n/a -XIFA n/a -XIFA -XIFA -XIFA
EEx n/a n/a -- n/a -XIFE n/a -XIFE -- -XIFE
II 2 G EEx ia IIC T4, T5 n/a n/a -XIFF n/a -XIFF n/a -XIFF -XIFF -XIFF
Factory Mutual & CSA -HC-XISC n/a -HC-XISC -HC-XISC n/a -HC-XISC -HC-XISC -HC-XISC -HC-XISC
Class I, Groups (A, B, C, D) -HCC-XISC n/a -HCC-XISC -HCC-XISC n/a -HCC-XISC -HCC-XISC -HCC-XISC -HCC-XISC
Class II, Groups (E, F & G)
Class III, Division 1
Unguarded type; push & hold to operate. -- -- -ME -- -MAE -- -M -ME -ME
Unguarded locking type; push to operate
and turn to lock. --
Guarded type; push & hold to operate -CML -- -- -CML -M5R -- -M5R --
(non-locking).
std -- -- std -M -- -G -- --
Seals
High nitrile compound suitable for
“sweet” natural gas, ammonia, R11, 12 or -- -- -- -- -- -- -11 -- --
13 freon.
std -3 std std -3 -3 -155 std std-
(included as standard on all hazardous
location solenoids)
Special Silencer/Dust Excluder -L14 -L14 -L14 -L14 -E14 -L14 -E14 -L14 -L14
Condition Solenoid Exhaust
** Not available with spade terminals or DIN style connectors or suffix -228L 31
WARNINGS REGARDING THE DESIGN APPLICATION,
INSTALLATION AND SERVICE OF VERSA PRODUCTS
The warnings below must be read and reviewed before designing a system utilizing, installing, electrical, mechanical, and safety codes, as well as applicable governmental regulations and
servicing, or removing a Versa product. Improper use, installation or servicing of a Versa laws must be complied with when installing or servicing a Versa product.
product could create a hazard to personnel and property.
should occur to a Versa product, do not operate the system containing the Versa product.
Versa products are not inherently dangerous. They are only a component of a larger system. Consult Versa for technical information.
The system in which a Versa product is used must include adequate safeguards to prevent
injury or damage in the event of system or product failure, whether this failure be of switches,
regulators, cylinders, valves or any other system component. System designers must provide
adequate warnings for each system in which a Versa product is utilized. These warnings,
including those set forth herein, should be provided by the designer to those who will come in
contact with the system. ship for a period of ten years from the date of manufacture, provided said items are used
Where questions exist regarding the applicability of a Versa product to a given use, inquiries limited to the replacement of the Versa product proved to be defective provided the alleg
edly defective product is returned to Versa or its authorized distributor.
from the manufacturer regarding any questioned application prior to proceeding.
Versa provides no other warranties, expressed or implied, except as stated above. There
INSTALLATION, OPERATION AND SERVICE WARNINGS
liability for breach of warranty as herein stated is the only and exclusive remedy and in no
event shall Versa be responsible or liable for incidental or consequential damages.
www.versa-valves.com
e-mail: sales@versa-valves.com