Anda di halaman 1dari 2

14 April, 2012 Emerson FZE

PO BOX 17033
Jebel Ali Free Zone (South)
Dubai, UAE
E: dmmc.quality@emerson.com

Calibration Data Sheet Consistent with ISO 10474 3.1B or EN 10204 3.1

Customer Information Manufacturer Information

Name: TRIZAC ABU DHABI Sales Order: 97301522


PO: FPO 1220.12 Line: 16

Device Information Calibration Information


Device Type: Pressure Transmitter
Tag No: WM24-PT-707 Factory: Dubai
Station Name: Station 13C
Serial No: 9172925 Operator ID: 1111397
Model No: 2051TG2A2B21BS5I1M5D4P1Q4Q8Q15A0227 Calibration Date: 4/14/2012 4:07:35PM

Module Serial No: 12480446


Output: Linear

Attached Models
0306RT22BA11SG

Equipment Used
EqNumber: EqName:
DMMC-ELEC-69 Pressure Calibrator
DMMC-ELEC-73 Pressure Calibrator
IC-00487 MultiMeter
IC-00493 Loadbox

Calibration Data

Range: 0.000 TO 100.000 PSIG


% of Range Applied Pressure Requested Applied Pressure Analog Output (mA) % Span Error Pass/Fail

100.000 100.000 PSI 100.0000 PSIG 20.0050 0.0313 PASS


80.000 80.000 PSI 80.0000 PSIG 16.8032 0.0200 PASS
60.000 60.000 PSI 60.0000 PSIG 13.6028 0.0175 PASS
40.000 40.000 PSI 40.0000 PSIG 10.4046 0.0288 PASS
20.000 20.000 PSI 20.0000 PSIG 7.2044 0.0275 PASS
0.000 0.000 PSI 0.0000 PSIG 4.0022 0.0138 PASS

Page 1 of 2 179172925_Q4-PRESSURE_DMMC_1
This is to certify that the listed product meets the applicable Rosemount Specifications.
Measuring and test equipment used in the manufacture and inspection of the listed product are
traceable to the National Institute of Standards and Technology. The calibration system was
designed to meet the intent of ANSI Z540-1-1994.

Venkatesh Chandran
Quality Manager, Rosemount MEA

Page 2 of 2 179172925_Q4-PRESSURE_DMMC_1