INFORMATION 1 (5)
Prepared (also subject responsible if other) No.
Cell Level Half Rate Load Allocation
1 Short Description..................................................................................................2
2 Revision Information............................................................................................2
3 Customer Benefits.................................................................................................2
4 Technical Description........................................................................................3
5 Feature activation/deactivation............................................................................3
Ericssonwide Internal
INFORMATION 2 (5)
Prepared (also subject responsible if other) No.
1 Short Description
Node: BSC
This feature provides cell level control of the existing half rate load allocation functionality.
When activated it will override the BSC level control.
Half rate load allocation optimises the usage of capacity when the traffic load is high, whilst
it offers the best possible speech quality when the traffic load is low. This is achieved by
changing the channel rate at allocation in accordance with the traffic load in the cell. At high
traffic load TCH/HR is allocated and at low traffic load TCH/FR is allocated.
2 Revision Information
PA1 First Issue
PA2 Activation/Deactivation section 5 added.
PA3 Additional note in relation to impact to OSS in part 3.
3 Customer Benefits
The EndUser
The customer will benefit from a better speech quality since half rate is only allocated when
there is a need for it in the cell (i.e. when there is no idle timeslots left).
The Operator
Ericssonwide Internal
INFORMATION 3 (5)
Prepared (also subject responsible if other) No.
Note: This command is defined with one new parameter for command RLDEC. The new
parameter is CELLOAD. This additional parameter will have no impact whatsoever with
the operation of OSS scripting.
4 Technical Description
This PDI will provided cell level control of the half rate load allocation functionality in
addition to the BSC level control.
The cell level control will be provided by the parameter CELLOAD in command RLDEC
(Radio Control Cell, Description Data, Change). The value range and default value of the are
as follows:
Range: 0100, 255
Default: 255 (OFF)
Unit: 1
Value: %
The cell level parameter will also be included in the printout command RLDEP (Radio
Control Cell Description Data, Print). If CELLOAD has the default value (255), no value
will be presented at command RLDEP.
If the cell level parameter (CELLOAD) is left at the default value (255), the half rate load
allocation in that cell is controlled by the value set across the BSC (with an exchange
property).
If the cell level parameter (CELLOAD) is changed from the default value (255), the half rate
load allocation in that cell is controlled by the cell level parameter (CELLOAD), which
overrides the BSC level setting.
Ericssonwide Internal
INFORMATION 4 (5)
Prepared (also subject responsible if other) No.
5 REQUIRMENTS
To install the adaptation for the CELLOAD parameter in the RLDEP printout, do the
following: (All files are included in software alignment package and can be found in the
”OSS” directory.)
6 Feature activation/deactivation
This feature can be turned on or off by setting a parameter CELLOAD in
command RLDEP. If the CELLOAD parameter is set to either 0 (zero) or
255 this feature will be turned off. Otherwise, it will be as on. Please
refer to OPI for interpretation of CELLOAD.
1). To activate:
eg.
RLDEC:CELL=cell,BCCHNO=bcchno,NEWNAME=newname,CELLOAD=50.
1). To deactivate:
eg.
RLDEC:CELL=cell,BCCHNO=bcchno,NEWNAME=newname,CELLOAD=255.