Applications
Wireless Broadband Networks
• WiMAX
• WiFi
• MESH
• Wireless Backhaul
Configurations Alvarion Radio Models
ALPU-ALVR
BreezeMax
Data 2 Ethernet
Service Voltage 55VDC
BreezeAccess
Cable Entry/Exit 2
Voltage Protection 130Vpk @ 150A 10/1000μs
BreezeNet
Level 152Vpk @ 1500A 8/20μs
suppression -D A T A D C +
+ D A TA D C -
2
3
D C 2 ( -)
D C 2 ( -)
Installation
Remove the cover by loosening the four captive cover screws using a Phillips CONCEALED
MOUNTING HOLES
screwdriver. Mount the ALPU-ALVR as close to the equipment to be protected
as possible using the provided hardware and the concealed mounting holes.
Mount the unit in the orientation shown.
Thread a multiconductor cable from the data source through the strain relief
adjacent to the marking on the PCB labeled “Input.”
Strip back the cable jacket as needed, then install the conductors into the IDC
connectors labeled “Input” - place the wires into the grooves in the connector,
leaving approximately 1/8” of wire overhanging, and press down firmly with the
punch-down tool until the wires firmly engage into the fork terminals.
Repeat this procedure for the outgoing multiconductor cable, using the EXTERNAL GND LUG
ACCEPTS 4-14 AWG
Tighten the strain reliefs to secure the cables (DO NOT OVER TORQUE!).
Replace the cover.
STRAIN RELIEF ACCEPTS
CABLE DIA. RANGE
0.250" THRU 0.375"
www.transtector.com sales@transtector.com
An ISO 9001:2000 and 14001 Certified Company 1453-036 Rev. A