Tension rod 3
7 1)
Coupler M10 to M100 S460 acc.to technical documentation 460 610
Turnbuckle 6
2)
Gusset plate 5 M10 to M100 ->S355 EN 1993-1-1:2005 EN 1993-1-1:2005
Component Annex System Material Techn. Delivery Condition Mechanical Properties
Size (Minimum Values)
Yield strength Tensile strength
Rp0,2 Rm
[N/mm2] [N/mm2]
1)
steel cast A4 acc.to technical documentation
Fork end 3 M10 to M100 G20Mn5 acc.to technical documentation 1)
335 600
connector
1)
G20NiMoCr4 acc.to technical documentation
1)
M10 to M16 8.8 acc.to technical documentation 665 800
Pin 4.1
1)
M20 to M100 8.8 acc.to technical documentation 685 882
Tension rod 3
7 1)
Coupler M10 to M100 S460 acc.to technical documentation 520 690
Turnbuckle 6
2)
Gusset plate 5 M10 to M100 ->S355 EN 1993-1-1:2005 EN 1993-1-1:2005
Füßgängerbrücke Walverdang,
Luxembourg
Contractor: Bohlen AG, Speicher
Treetop Walkway
at Lough Key Forest Park
Co. Roscommon, Republic of Ireland
This publication provides the technical details currently used by Macalloy in the manufacture of its components.
The company reserves the right to amend technical details as and where necessary in line with its policy of continuous development.
Macalloy, Caxton Way, Dinnington, Sheffield S25 3QE, U.K. Tel: +44 (0)1909 519200. Fax: +44 (0)1909 519201
Website: www.macalloy.com Email: sales@macalloy.com