Anda di halaman 1dari 297

PROJECT :-

SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

1. PROTECTION RELAY CONNECTION DIAGRAMS


( DOCUMENT NO. FROM 1KGG900573 – 09 TO 1KGG900573 – 15 )

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

CIRCULATING WATER PUMP A SWITCHGEAR ( 1BA -4)

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

CIRCULATING WATER PUMP B SWITCHGEAR (1BA -5)

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

FD FAN A SWITCHGEAR ( 1BA -6)

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

GR FAN A SWITCHGEAR ( 1BA -8)

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

BOILER FEED PUMP A SWITCHGEAR ( 1BA -10)

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

CONDENSATE PUMP A SWITCHGEAR ( 1BA -13)

ABB
Project :
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

COOLING WATER PUMP SWITCHGEAR ( 1BA -16)

ABB
PROJECT :-
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

2. PROTECTION SETTINGS
( DOCUMENT NO. 1KGG900573 - 16 )

ABB
ABB Motor 4/10/2008 8:24 AM
PTSP-O7 REF542

BLR FEED PP A Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 4800
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 320
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 90
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T trip °C = 150
Temp.for Alarm T warn °C = 100

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 1600
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 1280
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 4
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min = NA
Heating up - rated operation I = 0,2 -2In min = NA
Heating up - overcurrent I > 0,2 In min NA

Network data =
Current transformer - Ratio A = 400
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 Blr_Feed_PP_A_Mo_prot_V4E_Set Mot_Data
ABB Motor 4/10/2008 8:25 AM
PTSP-O7 HAZEM REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage : BLR FEED PP A Panel: 1BA-10 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPS Order: 4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 400 A
7 Motor rated current In m 320 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 320 A 0.800 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 1600 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 4.0 sec 4000 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 1120 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 6 min 360 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 76 C 76 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In Motor current Ie 0.800
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 35 560 A 1.750 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom ca.ambi.+70 deg C 95 C 95 C
24 Motor rated current 0,1... 5 In I nom 320 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 50.0 C 50 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 20 min 1200 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 7 min 420 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 7 min 420 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 150 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 100 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperazure 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.08 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Reset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In (Wdl) Startvalue 1.4 1.125 360 A 0.90 In
40 Overcurrent- time multiplier k 0.05 .. 1.5 0.208
41 Short-circuit- current I>>> 0,1..40,00 *In(Wdl) Startvalue 1,4 * Is(Ia) 1.875 3000 A 7.50 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 V 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.05 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 4800 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 Blr_Feed_PP_A_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:26 AM
PTSP-O7

Note: Inputs for Calculation Calculated values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: BLR FEED PP A

Tau: I< 0,1 Ie 20 min Cooling


Tau: 0,1 Ie< I < 2Ie 07 min Heating up 1
Tau: I>2Ie 07 min Heating up 2

Warning temp. 100 C Trip temperature 150 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
170

150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 Blr_Feed_PP_A_Mo_prot_V4E_Set Temp_curve
ABB Motor 4/10/2008 8:26 AM
PTSP-O7 REF542

CIRC WTR PP A Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 1027
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 79
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 120
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T warn °C = 140
Temp.for Alarm T trip °C = 130

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 395
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 316
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 1.5
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min = NA
Heating up - rated operation I = 0,2 -2In min = NA
Heating up - overcurrent I > 0,2 In min NA

Network data =
Current transformer - Ratio A = 100
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 Circ_Wtr_PP_A_Mo_prot_V4E_Set Mot_Data
ABB Motor 4/10/2008 8:27 AM
PTSP-O7 HAZEM REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage : CIRC WTR PP A Panel: 1BA-4 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPS Order:4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 100 A
7 Motor rated current In m 79 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 79 A 0.790 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 395 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 1.5 sec 1500 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 277 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 6 min 360 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 96 C 96 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 0.790
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 32.91 130 A 1.646 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom ca.ambi.+70 deg C 120 C 120 C
24 Motor rated current 0,1... 5 In I nom 79 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 60.0 C 60 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 20 min 1200 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 12 min 720 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 12 min 720 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 140 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 130 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperature 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.079 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Rerset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In Startvalue 1.4 1.14 90.06 A 0.90 In
40 Overcurrent time multiplier k 0.05 .. 1.5 0.800
41 Short-circuit- current I>>> 0,1..40,00 *In Startvalue 1,4 * Is(Ia) 2.025 800 A 8.00 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.050 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 1027 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 Circ_Wtr_PP_A_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:27 AM
PTSP-O7

Note: Inputs for Calculation Calculated Values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: CIRC WTR PP A

Tau: I< 0,1 Ie 20 min Cooling


Tau: 0,1 Ie< I < 2Ie 12 min Heating up 1
Tau: I>2Ie 12 min Heating up 2

Warning temp. 130 C Trip temperature 140 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
170

150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 Circ_Wtr_PP_A_Mo_prot_V4E_Set Temp_curve
ABB Motor 4/10/2008 8:28 AM
PTSP-O7 REF542

CIRC WTR PP B Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 1027
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 79
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 120
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T warn °C = 140
Temp.for Alarm T trip °C = 130

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 395
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 316
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 1.5
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min = NA
Heating up - rated operation I = 0,2 -2In min = NA
Heating up - overcurrent I > 0,2 In min NA

Network data =
Current transformer - Ratio A = 100
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 Circ_Wtr_PP_B_Mo_prot_V4E_Set Mot_Data
ABB Motor 4/10/2008 8:28 AM
PTSP-O7 HAZEM REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage : CIRC WTR PP B Panel: 1BA-5 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPS Order:4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 100 A
7 Motor rated current In m 79 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 79 A 0.790 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 395 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 1.5 sec 1500 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 277 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 6 min 360 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 96 C 96 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In Motor current Ie 0.790
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 32.91 130 A 1.646 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom ca.ambi.+70 deg C 120 C 120 C
24 Motor rated current 0,1... 5 In I nom 79 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 60.0 C 60 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 20 min 1200 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 12 min 720 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 12 min 720 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 140 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 130 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperature 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.079 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Reset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In (Wdl) Startvalue 1.4 1.14 90.06 A 0.90 In
40 Overcurrent time multiplier k 0.05 .. 1.5 0.800
41 Short-circuit- current I>>> 0,1..40,00 *In(Wdl) Startvalue 1,4 * Is(Ia) 2.025 800 A 8.00 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.05 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 1027 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 Circ_Wtr_PP_B_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:29 AM
PTSP-O7

Note: Inputs for Calculation Calculated Values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: CIRC WTR PP B

Tau: I< 0,1 Ie 20 min Cooling


Tau: 0,1 Ie< I < 2Ie 12 min Heating up 1
Tau: I>2Ie 12 min Heating up 2

Warning temp. 130 C Trip temperature 140 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
170

150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 Circ_Wtr_PP_B_Mo_prot_V4E_Set Temp_curve
ABB Motor 4/10/2008 8:29 AM
PTSP-O7 REF542

COND PP A Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 445
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 32
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 120
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T trip °C = 140
Temp.for Alarm T warn °C = 130

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 160
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 128
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 1
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min = NA
Heating up - rated operation I = 0,2 -2In min = NA
Heating up - overcurrent I > 0,2 In min NA

Network data =
Current transformer - Ratio A = 50
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 Cond_PP_A_Mo_prot_V4E_Set Mot_Data
ABB Motor 4/10/2008 8:30 AM
PTSP-O7 REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage :COND PP A Panel: 1BA-13 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPS Order:4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 50 A
7 Motor rated current In m 32 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 32 A 0.640 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 160 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 1.0 sec 1000 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 112 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 9 min 540 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 96 C 96 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In Motor current Ie 0.640
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 34.37 55 A 1.719 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom 120 C 120 C
24 Motor rated current 0,1... 5 In I nom 32 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 60.0 C 60 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 30 min 1800 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 12 min 720 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 12 min 720 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 140 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 130 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperazure 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.064 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Reset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In (Wdl) Startvalue 1.4 1.25 40 A 0.80 In
40 Overcurrent time multiplier k 0.05 .. 1.5 0.800
41 Short-circuit- current I>>> 0,1..40,00 *In(Wdl) Startvalue 1,4 * Is(Ia) 2.0312 325 A 6.50 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.05 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 445 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 Cond_PP_A_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:30 AM
PTSP-O7

Note: Inputs for calculation Calculated values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: COND PP A

Tau: I< 0,1 Ie 30 min Cooling


Tau: 0,1 Ie< I < 2Ie 12 min Heating up 1
Tau: I>2Ie 12 min Heating up 2

Warning temp. 130 C Trip temperature 140 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
170

150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 Cond_PP_A_Mo_prot_V4E_Set Temp_curve
ABB Motor 4/10/2008 8:30 AM
PTSP-O7 REF542

COOLG WTR PP Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 500
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 36
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 120
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T trip °C = 140
Temp.for Alarm T warn °C = 130

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 180
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 144
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 1.6
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min = NA
Heating up - rated operation I = 0,2 -2In min = NA
Heating up - overcurrent I > 0,2 In min NA

Network data =
Current transformer - Ratio A = 50
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 Coolg_Wtr_PP_Mo_prot_V4E_Set Mot_Data
ABB Motors 4/10/2008 8:31 AM
PTSP-O7 HAZEM REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage : COOLG WTR PP Panel: 1BA -16 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPZ Order: 4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 50 A
7 Motor rated current In m 36 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 36 A 0.720 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 180 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 1.6 sec 1600 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 126 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 8.4 min 504 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 96 C 96 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In Motor current Ie 0.720
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 33.334 60 A 1.667 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom ca.ambi.+70 deg C 120 C 120 C
24 Motor rated current 0,1... 5 In I nom 36 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 60.0 C 60 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 28 min 1680 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 12 min 720 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 12 min 720 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 140 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 130 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperazure 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.072 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Reset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In (Wdl) Startvalue 1.4 1.25 45 A 0.90 In
40 Overcurrent time multiplier k 0.05 .. 1.5 0.800
41 Short-circuit- current I>>> 0,1..40,00 *In(Wdl) Startvalue 1,4 * Is(Ia) 2.0833 375 A 7.50 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.05 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 500 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 Coolg_Wtr_PP_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:31 AM
PTSP-O7

Note: Inputs for calculation Calculated values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: COOLG WTR PP

Tau: I< 0,1 Ie 28 min Cooling


Tau: 0,1 Ie< I < 2Ie 12 min Heating up 1
Tau: I>2Ie 12 min Heating up 2

Warning temp. 130 C Trip temperature 140 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
170

150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 Coolg_Wtr_PP_Mo_prot_V4E_Set Temp_curve
ABB Motor 4/10/2008 8:32 AM
PTSP-O7 REF542

FD FAN A Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 2352
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 163
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 90
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T trip °C = 150
Temp.for Alarm T warn °C = 100

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 815
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 652
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 5
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min =
Heating up - rated operation I = 0,2 -2In min =
Heating up - overcurrent I > 0,2 In min

Network data =
Current transformer - Ratio A = 200
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 FD_Fan_A_Mo_prot_V4E_Set Mot_Data
ABB Motor 4/10/2008 8:32 AM
PTSP-O7 HAZEM REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage : FD FAN A Panel: 1BA-6 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPS Order: 4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 200 A
7 Motor rated current In m 163 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 163 A 0.815 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 815 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 5.0 sec 5000 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 571 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 6.3 min 378 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 72 C 72 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In Motor current Ie 0.815
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 34.35 280 A 1.718 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom ca.ambi.+70 deg C 90 C 90 C
24 Motor rated current 0,1... 5 In I nom 163 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 50.0 C 50 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 21 min 1260 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 7 min 420 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 7 min 420 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 150 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 100 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperazure 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.0815 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Reset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In (Wdl) Startvalue 1.4 1.104 179.952 A 0.90 In
40 Overcurrent time multiplier k 0.05 .. 1.5 0.208
41 Short-circuit- current I>>> 0,1..40,00 *In(Wdl) Startvalue 1,4 * Is(Ia) 2.0858 1700 A 8.50 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.05 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 2352 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 FD_Fan_A_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:32 AM
PTSP-O7

Note: Inputs for calculation Calculated values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: FD FAN A

Tau: I< 0,1 Ie 21 min Cooling


Tau: 0,1 Ie< I < 2Ie 07 min Heating up 1
Tau: I>2Ie 07 min Heating up 2

Warning temp. 100 C Trip temperature 150 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 FD_Fan_A_Mo_prot_V4E_Set Temp_curve
ABB Motor 4/10/2008 8:33 AM
PTSP-O7 REF542

GR FAN A Motor Data

Motor-Typ
Rated data
Rated Power(output) Sn KW = 692
Rated voltage Un V = 11000
Rated frequency Fn Hz = 50
Rated current on Un (rated voltage) In A = 50
Rated current on 0.8 Un In-0,8 A =
Max. permissible Permanent current Imax. Th sec =

Max. trip time for 6 x In T 6 max sec =


Nom-Temperature T nom °C = 90
max.-Temperature T max
Ambient temperature T amb °C = 55
Temp.for Trip T trip °C = 150
Temp.for Alarm T warn °C = 100

Insulation class A; B F Class =


Start data:
Start current on Un (rated voltage) Ia A = 250
Start factor on Un (rated voltage) x In = 5
Start current on 0.8Un (rated voltage) Ia_0,8 A = 200
Start factort on 0.8Un (rated voltage) x In = 4
Max. Starttime on Un ta sec = 43
Max. Starttime on 0,8x Un ta_0,8 sec =
Max. block period of the Motors te > ta sec =
Max. block period of the Motors te < ta sec =

Admissible number of starts N cold = 3


Admissible number of starts N warm = 2
Tau-Time constant ( ZK )
Stillstand ( cooling) I < 0,2 In min =
Heating up - rated operation I = 0,2 -2In min =
Heating up - overcurrent I > 0,2 In min

Network data =
Current transformer - Ratio A = 100
min. Ground current A = 3
ZCT(cable change transformer) =
for Earth leakage currents ratio

min. dates for calculation

Note:
In the case of deviation of the operating voltage Un to an undervoltage Unu
changes the startcurrent(Iau) according to that formula

Iau = Ian x ( Unu/ Un)


Ian = startcurrent on rated - voltage
Iau = startcurrent on under - voltage
Un = Rated voltage
Unu = Under -rated voltage

1 OF 1 GR_Fan_A_Mo_prot_V4E_Set Mot_Data
ABB Motor 4/10/2008 8:34 AM
PTSP-O7 HAZEM REF 542

1 Setting value for motor protection REF -SW-Version V4E.03b

2 Motor usage : GR FAN A Panel: 1BA-8 Input -Data


3 Project: 11kV UNIT SWGR AT AZSPS Order: 4688190 Calculating data
4 Date:
REF sectting- REF-Dialog- Stand.- Primary-value Ref Setting value
5 Function Default
range display value
6 CT rated value In 100 A
7 Motor rated current In m 50 A
8 Start monitoring:
9 Motor rated current In 0,2 ...2 * In =Ie Motor current Ie 50 A 0.500 In
10 Start current on Un ( 0,8Un) Ia 1,0 ... 20,00 * Ie = Ia Start value Is 250 A 5.00 Ie
11 Start time on Un (0,8Un) ta 40...300 000 ms time 43.0 sec 43000 ms
12 as Motorstart analyses 0,2 .. 0,8 *Is Motorstart 0,7 * Is 175 A 0.70 Is
13 Number of starts
14 Permissible Warmstarts 1.....10 No. of Warmstarts 2 2 2
15 Permissible coldstarts 1.....10 No. of coldstarts 3 3 3
16 reset time for 1Start 1.…7200 sec. time 0,3 xZK Off 6.3 min 378 sec
17 Temperature for Warmstart 20....200 deg.C Temp. f. Warmst. 0,8 x(Tnom) 72 C 72 C
18 blocking Rotor
19 Motor rated current In 0,2 ...2 * In Motor current Ie 0.500
20 Start current 1.000 ... 27.778 * In Startvalue 80 % Ia 32 80 A 1.600 Ie
21 delay time block. Rotor 40 . 30 000 msec. time ( ta < te)=0,6x ta 0.05 sec 50 msec
22 Thermal protection
23 Operating temperature 50..400 deg.[C] T nom ca.ambi.+70 deg C 90 C 90 C
24 Motor rated current 0,1... 5 In I nom 50 A
25 Start temperature 10 .. 400 deg.[C] T ini 50%Tnom 50.0 C 50 C
26 Cooling time constant at Stillstand 10 .. 100 000 [s] ZK off 3....5 ZK Normal 21 min 1260 sec
27 Warming time on 0,1--2x Ie 10 .. 20 000 [s] ZK Normal Isolierklase A,B,F 7 min 420 sec
28 Warming time on > 2x Ie 10 . .20 000 [s] ZK fault 7 min 420 sec
29 Trip temp. 50 .. 400 deg.[C] T Max. ca 1,1 * Tnom 150 C
30 Warntemp 50 .. 400 deg.[C] T Warn. ca1,05 * Tnom 100 C
31 Ambient temp. 10 .. 50 deg.[C] T Ambient 30 deg C 40 55 C
32 Reset Temperazure 10 .. 400 deg.[C] T (rst ) Ambient -temp 55 C
33 Unbalaced load
34 Start thresholdexpressed 0,05 .. 0,30 In / CT Is 10% Motor 0.05 10 %
35 Heating parameter of motor 0.5 .. 30 K 10 0.5
36 Reset the thermal memory 0 .. 2000 sec Reset time 60 60
37 % of Reset 0 .. 100% Time decreasing rate 0 0
38 Overcurrent / short-circuit protection
39 Overcurrent - current I> 0,05...40 *In (Wdl) Startvalue 1.4 1.2 60 A 0.60 In
40 Overcurrent time multiplier k 0.05 .. 1.5 1.023
41 Short-circuit- current I>>> 0,1..40,00 *In(Wdl) Startvalue 1,4 * Is(Ia) 2 500 A 5.00 In
42 Short-circuit- Triptime t>>> 15 . .300 000 msec time 50 msec 0.05 sec 50 msec
43 Earth Fault -protection CT = 60 A 1.00 A
44 Direc. E/F current Ie> 0,05..40*In Startvalue 0,1 * Ie 5.4 A 0.09 In
45 Direc. E/F voltage Uo> 0.02 .. 0.7 Uo Voltage 10 0.10 Uo
46 Direc. E/F triptime te> 40 .. 30 000 msec time 0.05 sec 50 msec
47 E/F base current Ie> 0,05..40*In Startvalue 1 3 0.05 In
48 E/F time multiplier k 0.05 .. 1.5 0.100
49 Low load
50 Nom. Real power 50 .. 1000000 kW 692 kW
51 Min. load 5 .. 100 % Pn 40 %
52 Min. current 2 .. 20 % In 20 %
53 Op. time 1.0 .. 1000.0 s 600 sec

Prepared: Hazem M. Al-Khalifa

1 OF 1 GR_Fan_A_Mo_prot_V4E_Set Setting_Tab
ABB REF 542 4/10/20088:34 AM
PTSP-O7

Note: Inputs for calculation Calculated values

Customer: AZSPS
Project: 11kV UNIT SWGR
Motor: GR FAN A

Tau: I< 0,1 Ie 21 min Cooling


Tau: 0,1 Ie< I < 2Ie 07 min Heating up 1
Tau: I>2Ie 07 min Heating up 2

Warning temp. 100 C Trip temperature 150 C

Temperatur Curve
T Umgebungstemp für Berechnung:
[C]
T ambient temp. for calculation
150

130

110

90

70

50

30
0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

Motor Current
6
5
4
3
2
1
0
[A] 0 0 0 00 00 00 00 00 00 00 00 00
.0 .0 5. 5. 5. 5. 5. 5. 5. 5. 5.
15 30 54 4 4 4 4 4 4 4 84
15 25 35 45 55 65 75 28 [s]

1 OF 1 GR_Fan_A_Mo_prot_V4E_Set Temp_curve
PROJECT :-
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

3. PROTECTION LOGICS
( DOCUMENT NO. 1KGG900573 - 17 )

ABB
1/25 BLR FEED PP A U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 124


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

125
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 BLR FEED PP A U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 BLR FEED PP A U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 BLR FEED PP A U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 BLR FEED PP A U1

114 132
( 11 ) /01 SIGNAL 1
( 403 ) /24 CB CLOSING BLOCK 123
( 27 ) /02 CB DISCHARGED ( 91 ) /05 CB OFF CMD ( 13 ) /05
( 92 ) /05 CB OFF CMD 116 ( 23 ) /06 CB- UINIT TEST POS. ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 33 ) /02 SELECTOR MODE 'TEST' ( 66 ) /05 CB OFF CMD
( 70 ) /05
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0 133
( 20 ) /01 SIGNAL 0 ( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 12 ) /05
( 23 ) /06 CB- UINIT TEST POS.
( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD
138
( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 140
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

141
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

142
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
129
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 BLR FEED PP A U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 BLR FEED PP A U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

( 11 ) /01 SIGNAL 1
62 ESW POSITION
( 25 ) /06 ESW O PEN POS. 88 96
( 128 ) /07
( 33 ) /02 SELECTOR MODE 'TEST' ( 126 ) /07
( 25 ) /06 ESW O PEN POS. 8

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 BLR FEED PP A U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 BLR FEED PP A U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 137
( 22 ) /05 CB OPEN POS. 121
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 BLR FEED PP A U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 BLR FEED PP A U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

181
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 BLR FEED PP A U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 BLR FEED PP A U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 BLR FEED PP A U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 145

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 BLR FEED PP A U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
148
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 182

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 147

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 BLR FEED PP A U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 BLR FEED PP A U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 183
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 162


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 180

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 163


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 179

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 164


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 185

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 161


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 BLR FEED PP A U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
146

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 BLR FEED PP A U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 BLR FEED PP A U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 BLR FEED PP A U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 BLR FEED PP A U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 BLR FEED PP A U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 BLR FEED PP A U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 4000
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
128
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 BLR FEED PP A U1

139
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


1/25 CIRC WTR PP A U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 124


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

125
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 CIRC WTR PP A U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 CIRC WTR PP A U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 CIRC WTR PP A U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 CIRC WTR PP A U1

114 132
( 403 ) /24 CB CLOSING BLOCK ( 11 ) /01 SIGNAL 1
( 91 ) /05 CB OFF CMD 123
( 27 ) /02 CB DISCHARGED ( 13 ) /05
( 92 ) /05 CB OFF CMD 116 ( 23 ) /06 CB- UINIT TEST POS. ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 33 ) /02 SELECTOR MODE 'TEST'
( 70 ) /05 ( 66 ) /05 CB OFF CMD
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0 133
( 20 ) /01 SIGNAL 0 ( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 23 ) /06 CB- UINIT TEST POS. ( 12 ) /05

137 ( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD


( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 142
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

140
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

141
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
128
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 CIRC WTR PP A U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 CIRC WTR PP A U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

( 11 ) /01 SIGNAL 1
62 ESW POSITION
( 25 ) /06 ESW O PEN POS. 88 96
( 128 ) /07
( 33 ) /02 SELECTOR MODE 'TEST' ( 126 ) /07
( 25 ) /06 ESW O PEN POS. 8

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 CIRC WTR PP A U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 CIRC WTR PP A U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 138
( 22 ) /05 CB OPEN POS. 121
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 CIRC WTR PP A U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 CIRC WTR PP A U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

182
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 CIRC WTR PP A U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 CIRC WTR PP A U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 CIRC WTR PP A U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 146

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 CIRC WTR PP A U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
147
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 183

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 148

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 CIRC WTR PP A U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 CIRC WTR PP A U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 181
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 162


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 180

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 163


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 179

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 164


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 185

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 161


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 CIRC WTR PP A U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
145

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 CIRC WTR PP A U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 CIRC WTR PP A U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 CIRC WTR PP A U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 CIRC WTR PP A U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 CIRC WTR PP A U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 CIRC WTR PP A U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 1500
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
129
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 CIRC WTR PP A U1

139
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


1/25 CIRC WTR PP B U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 124


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

125
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 CIRC WTR PP B U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 CIRC WTR PP B U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 CIRC WTR PP B U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 CIRC WTR PP B U1

114 132
( 403 ) /24 CB CLOSING BLOCK ( 11 ) /01 SIGNAL 1
( 91 ) /05 CB OFF CMD 121
( 27 ) /02 CB DISCHARGED ( 13 ) /05
( 92 ) /05 CB OFF CMD 116 ( 23 ) /06 CB- UINIT TEST POS. ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 33 ) /02 SELECTOR MODE 'TEST'
( 70 ) /05 ( 66 ) /05 CB OFF CMD
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0 133
( 20 ) /01 SIGNAL 0 ( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 23 ) /06 CB- UINIT TEST POS. ( 12 ) /05

139 ( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD


( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 140
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

142
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

141
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
129
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 CIRC WTR PP B U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 CIRC WTR PP B U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

( 11 ) /01 SIGNAL 1
ESW POSITION
62
( 25 ) /06 ESW O PEN POS. 88 96
( 128 ) /07
( 33 ) /02 SELECTOR MODE 'TEST' ( 126 ) /07
( 25 ) /06 ESW O PEN POS. 8

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 CIRC WTR PP B U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 CIRC WTR PP B U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 137
( 22 ) /05 CB OPEN POS. 123
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 CIRC WTR PP B U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 CIRC WTR PP B U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

182
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 CIRC WTR PP B U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 CIRC WTR PP B U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 CIRC WTR PP B U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 146

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 CIRC WTR PP B U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
147
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 183

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 148

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 CIRC WTR PP B U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 CIRC WTR PP B U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 181
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 162


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 180

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 163


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 179

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 164


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 185

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 161


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 CIRC WTR PP B U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
145

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 CIRC WTR PP B U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 CIRC WTR PP B U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 CIRC WTR PP B U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 CIRC WTR PP B U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 CIRC WTR PP B U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 CIRC WTR PP B U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 1500
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
128
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 CIRC WTR PP B U1

138
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


1/25 COND PP A U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 125


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

124
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 COND PP A U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 COND PP A U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 COND PP A U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 COND PP A U1

132
114 ( 11 ) /01 SIGNAL 1
( 403 ) /24 CB CLOSING BLOCK
( 91 ) /05 CB OFF CMD 123
( 27 ) /02 CB DISCHARGED ( 23 ) /06 CB- UINIT TEST POS. ( 13 ) /05
( 92 ) /05 CB OFF CMD 116
( 33 ) /02 SELECTOR MODE 'TEST' ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 66 ) /05 CB OFF CMD
( 70 ) /05
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0 133
( 20 ) /01 SIGNAL 0 ( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 23 ) /06 CB- UINIT TEST POS. ( 12 ) /05
137 ( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD
( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 142
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

140
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

141
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
128
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 COND PP A U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 COND PP A U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

( 11 ) /01 SIGNAL 1
62 ESW POSITION
( 25 ) /06 ESW O PEN POS. 88 96
( 126 ) /07
( 33 ) /02 SELECTOR MODE 'TEST' ( 128 ) /07
( 25 ) /06 ESW O PEN POS. 8

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 COND PP A U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 COND PP A U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 138
( 22 ) /05 CB OPEN POS. 121
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 COND PP A U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 COND PP A U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

181
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 COND PP A U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 COND PP A U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 COND PP A U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 145

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 COND PP A U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
148
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 182

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 147

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 COND PP A U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 COND PP A U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 183
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 162


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 180

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 163


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 179

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 164


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 185

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 161


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 COND PP A U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
146

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 COND PP A U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 COND PP A U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 COND PP A U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 COND PP A U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 COND PP A U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 COND PP A U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 1000
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
129
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 COND PP A U1

139
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


1/25 COOLG WTR PP U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 125


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

124
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 COOLG WTR PP U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 COOLG WTR PP U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 COOLG WTR PP U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 COOLG WTR PP U1

132
114 ( 11 ) /01 SIGNAL 1
( 403 ) /24 CB CLOSING BLOCK ( 91 ) /05 CB OFF CMD 123
( 27 ) /02 CB DISCHARGED ( 23 ) /06 CB- UINIT TEST POS. ( 13 ) /05
( 92 ) /05 CB OFF CMD 116
( 33 ) /02 SELECTOR MODE 'TEST' ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 66 ) /05 CB OFF CMD
( 70 ) /05
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0 133
( 20 ) /01 SIGNAL 0 ( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 23 ) /06 CB- UINIT TEST POS. ( 12 ) /05
( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD
137
( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 142
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

140
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

141
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
128
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 COOLG WTR PP U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 COOLG WTR PP U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

62 ( 11 ) /01 SIGNAL 1
( 25 ) /06 ESW O PEN POS. ESW POSITION

( 126 ) /07 88 96
( 33 ) /02 SELECTOR MODE 'TEST'
( 128 ) /07
( 25 ) /06 ESW O PEN POS. 8

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 COOLG WTR PP U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 COOLG WTR PP U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 138
( 22 ) /05 CB OPEN POS. 121
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 COOLG WTR PP U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 COOLG WTR PP U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

181
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 COOLG WTR PP U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 COOLG WTR PP U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 COOLG WTR PP U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 146

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 COOLG WTR PP U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
147
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 182

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 148

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 COOLG WTR PP U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 COOLG WTR PP U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 179
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 164


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 185

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 161


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 183

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 162


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 180

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 163


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 COOLG WTR PP U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
145

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 COOLG WTR PP U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 COOLG WTR PP U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 COOLG WTR PP U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 COOLG WTR PP U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 COOLG WTR PP U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 COOLG WTR PP U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 1600
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
129
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 COOLG WTR PP U1

139
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


1/25 FD FAN A U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 124


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

125
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 FD FAN A U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 FD FAN A U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 FD FAN A U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 FD FAN A U1

114 132
( 11 ) /01 SIGNAL 1
( 403 ) /24 CB CLOSING BLOCK
( 91 ) /05 CB OFF CMD 123
( 27 ) /02 CB DISCHARGED ( 13 ) /05
116 ( 23 ) /06 CB- UINIT TEST POS.
( 92 ) /05 CB OFF CMD ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 33 ) /02 SELECTOR MODE 'TEST'
( 70 ) /05 ( 66 ) /05 CB OFF CMD
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0 133
( 20 ) /01 SIGNAL 0 ( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 23 ) /06 CB- UINIT TEST POS. ( 12 ) /05
138 ( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD
( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 140
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

141
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

142
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
129
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 FD FAN A U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 FD FAN A U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

( 11 ) /01 SIGNAL 1
62 ESW POSITION
( 25 ) /06 ESW O PEN POS. 88 96
( 128 ) /07
( 33 ) /02 SELECTOR MODE 'TEST' ( 126 ) /07
8
( 25 ) /06 ESW O PEN POS.

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 FD FAN A U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 FD FAN A U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 137
( 22 ) /05 CB OPEN POS. 121
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 FD FAN A U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 FD FAN A U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

182
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 FD FAN A U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 FD FAN A U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 FD FAN A U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 145

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 FD FAN A U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
148
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 183

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 147

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 FD FAN A U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 FD FAN A U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 181
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 162


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 180

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 163


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 179

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 164


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 185

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 161


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 FD FAN A U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
146

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 FD FAN A U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 FD FAN A U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 FD FAN A U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 FD FAN A U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 FD FAN A U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 FD FAN A U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 5000
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
128
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 FD FAN A U1

139
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


1/25 GR FAN A U1

118 127
( 24 ) /06 CB- UINIT SERVICE POS.
( 19 ) /01 PANEL IN SERVICE
( 21 ) /05 CB CLOSE POS.

( 19 ) /01 PANEL IN SERVICE Operating hours: 0.000 h


126

0
( 63 ) /01 131
( 11 ) /01 SIGNAL 1

( 20 ) /01 SIGNAL 0
( 11 ) /01 SIGNAL 1
67 ch 401

( 18 ) /01 SIGNAL 1 RISE DELAY

Time [ms] 500 125


1 ( 20 ) /01 SIGNAL 0

( 20 ) /01 SIGNAL 0 ( 137 ) /01 CB UNIT RACKED OUT

Adr.:15

123
( 23 ) /06 CB- UINIT TEST POS.

( 14 ) /01 PANEL ALARM ( 137 ) /01 CB UNIT RACKED OUT

2
64 Adr.:10
( 15 ) /01
( 16 ) /01
( 202 ) /01
90 97 ch 409

( 65 ) /01 ( 17 ) /01 ACKNOLEDGEMENT


( 34 ) /03 RESET ALARM

Time [ms] 200

135
( 151 ) /05 CB DEF POSITION
( 137 ) /01 CB UNIT RACKED OUT
( 74 ) /06 CB-UNIT DEF POS.

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


2/25 GR FAN A U1

TRIP COIL
38

( 28 ) /02 TRIPPING COIL FAIL


8

Adr.:28, Inv.

UPSTREAM CB OFF
34

( 29 ) /02 UPSTREAM CB OFF


9

Adr.:29
MCB CONTROL OFF
35

( 30 ) /02 MCB CONTROL OFF


10

Adr.:30

MCB SPACE HTR OFF


4

( 31 ) /02 MCB SPACE HEATER OFF


11

Adr.:31
MCB MOTOR CHARG. OFF
5

( 32 ) /02 MCB MOTOR CHARG. OFF


12

Adr.:32

SEL 'TEST'
6

( 33 ) /02 SELECTOR MODE 'TEST'


13

Adr.:33

SEL 'LOCAL'
CB DISCHARGED 7
3
( 26 ) /02 SELECTOR MODE 'LOCAL'
( 27 ) /02 CB DISCHARGED 14
7

Adr.:34
Adr.:27

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


3/25 GR FAN A U1

EXTERNAL TRIP 1 REMOTE CB OFF

36 33

( 35 ) /03 EXTERNAL TRIP 1 ( 42 ) /03 REMOTE CB OFF


15 22

Adr.:35 Adr.:42

EXTERNAL TRIP 2 SPARE

37 31

( 36 ) /03 EXTERNAL TRIP 2 ( 34 ) /03 RESET ALARM


16 23

Adr.:36 Adr.:43

SEL 'REMOTE' SPARE


15 8

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 44 ) /03


17 24

Adr.:37 Adr.:44

SEL 'OFF' SPARE


14 30

( 38 ) /03 SELECTOR MODE 'OFF' ( 45 ) /03


18 25

Adr.:38 Adr.:45
SPARE SPARE
13 9

( 39 ) /03 ( 46 ) /03
19 26

Adr.:39 Adr.:46

SPARE SPARE
12 10

( 40 ) /03 ( 47 ) /03
20 27

Adr.:40 Adr.:47

REMOTE CB ON SPARE
32 11

( 41 ) /03 REMOTE CB ON ( 48 ) /03


21 28

Adr.:41 Adr.:48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


4/25 GR FAN A U1

SPARE SPARE
16 22

( 49 ) /04 ( 56 ) /04
29 36

Adr.:111 Adr.:118
SPARE SPARE
17 23

( 50 ) /04 ( 57 ) /04
30 37

Adr.:112 Adr.:119
SPARE SPARE
18 24

( 51 ) /04 ( 58 ) /04
31 38

Adr.:113 Adr.:120

SPARE SPARE
19 25
( 52 ) /04 ( 59 ) /04
32 39

Adr.:114 Adr.:121
SPARE SPARE
29 26

( 53 ) /04 ( 60 ) /04
33 40

Adr.:115 Adr.:122

SPARE SPARE
20 27

( 54 ) /04 ( 61 ) /04
34 41

Adr.:116 Adr.:123

SPARE SPARE
21 28
( 55 ) /04 ( 62 ) /04
35 42

Adr.:117 Adr.:124

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


5/25 GR FAN A U1

114 132
( 11 ) /01 SIGNAL 1
( 403 ) /24 CB CLOSING BLOCK
( 91 ) /05 CB OFF CMD 121
( 27 ) /02 CB DISCHARGED ( 13 ) /05
116 ( 23 ) /06 CB- UINIT TEST POS.
( 92 ) /05 CB OFF CMD ( 33 ) /02 SELECTOR MODE 'TEST' ( 68 ) /05 OFF CMD
( 98 ) /13 MCB MOTOR CHARG. OFF ( 66 ) /05 CB OFF CMD
( 70 ) /05
( 38 ) /03 SELECTOR MODE 'OFF'
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 133
( 11 ) /01 SIGNAL 1
( 20 ) /01 SIGNAL 0 ( 87 ) /05 ( 96 ) /05 CB CLOSE CMD 122
( 23 ) /06 CB- UINIT TEST POS. ( 12 ) /05
138 ( 33 ) /02 SELECTOR MODE 'TEST' ( 64 ) /05 CLOSE CMD
( 99 ) /05 CB CLOSE CMD
( 24 ) /06 CB- UINIT SERVICE POS.
( 77 ) /06 ES INTERLOCK
( 22 ) /05 CB OPEN POS.
( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1 ( 114 ) /05
( 11 ) /01 SIGNAL 1 141
( 11 ) /01 SIGNAL 1

( 23 ) /06 CB- UINIT TEST POS.

142
112 ( 22 ) /05 CB OPEN POS.
( 38 ) /03 SELECTOR MODE 'OFF' ( 72 ) /05 CB OPEN POS. DEF
( 100 ) /21 PROTECT.TRIP ( 157 ) /05 CB NO COMMAND
( 20 ) /01 SIGNAL 0
( 97 ) /05 CB INTERLOCKING

140
( 84 ) /05 ( 21 ) /05 CB CLOSE POS.
( 92 ) /05 CB OFF CMD ( 73 ) /05 CB CLOSE POS.DEF
87
( 42 ) /03 REMOTE CB OFF ( 157 ) /05 CB NO COMMAND
( 11 ) /01 SIGNAL 1
( 43 ) /05 LOCAL AND REMOTE
113 ch 419 CIRCUIT- BREAKER
( 66 ) /05 CB OFF CMD
129
( 22 ) /05 CB OPEN POS.
( 21 ) /05 CB CLOSE POS.
21 2
89 Time [ms] 100 ( 151 ) /05 CB DEF POSITION
CB
( 41 ) /03 REMOTE CB ON 95 ch 416
( 90 ) /05 CB ON CMD ( 99 ) /05 CB CLOSE CMD
( 43 ) /05 LOCAL AND REMOTE 22 1
( 11 ) /01 SIGNAL 1 ( 93 ) /05

Time [ms] 100 Adr.:10

( 91 ) /05 CB OFF CMD


61 ( 96 ) /05 CB CLOSE CMD
( 26 ) /02 SELECTOR MODE 'LOCAL' 134
( 43 ) /05 LOCAL AND REMOTE
( 37 ) /03 SELECTOR MODE 'REMOTE' ( 157 ) /05 CB NO COMMAND

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


6/25 GR FAN A U1

CB - UINIT POS
39
( 23 ) /06 CB- UINIT TEST POS.
( 24 ) /06 CB- UINIT SERVICE POS.
0 3

( 74 ) /06 CB-UNIT DEF POS.

0 4

Adr.:15

EARTH SWITCH POS.


49

( 25 ) /06 ESW O PEN POS.


5

Adr.:16, Inv.

52

( 25 ) /06 ESW O PEN POS. ( 77 ) /06 ES INTERLOCK

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


7/25 GR FAN A U1

208
( 89 ) /25 CB-TRIPPED STORE

136 ch 400

( 21 ) /05 CB CLOSE POS.


( 69 ) /07 143
( 78 ) /07

Time [ms] 500


( 22 ) /05 CB OPEN POS. ( 76 ) /07 ( 82 ) /07
192
( 11 ) /01 SIGNAL 1
174 ch 402
( 102 ) /21 PROTECTION TRIP ( 75 ) /07 VCB TRIP
222

219 ( 83 ) /07 CB TRIPPED 9


Time [ms] 1000
( 17 ) /01 ACKNOLEDGEMENT
Adr.:49

( 11 ) /01 SIGNAL 1
SEL 'LOCAL'
74

( 26 ) /02 SELECTOR MODE 'LOCAL'


5

Adr.:5

( 11 ) /01 SIGNAL 1
62 ESW POSITION
( 25 ) /06 ESW O PEN POS. 88 96
( 128 ) /07
( 33 ) /02 SELECTOR MODE 'TEST' ( 126 ) /07
( 25 ) /06 ESW O PEN POS. 8

Adr.:8

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


8/25 GR FAN A U1

( 11 ) /01 SIGNAL 1
OC TRIP
149 150
( 271 ) /17 LOCKED ROTOR TRIP
( 140 ) /08
( 105 ) /21 50 OC INST DEF TRIP 3

Adr.:6

( 11 ) /01 SIGNAL 1

DEF TRIP
93

( 108 ) /21 64G DEF TRIP


4

Adr.:9

( 11 ) /01 SIGNAL 1
KEY SWITCH LOCAL
70

( 26 ) /02 SELECTOR MODE 'LOCAL'


6

Adr.:24

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


9/25 GR FAN A U1

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


49 TRIP RELEASE UNIT CB
94 137
( 22 ) /05 CB OPEN POS. 124
( 408 ) /21 46 UNBALANCE TRIP ( 23 ) /06 CB- UINIT TEST POS.
( 131 ) /09 CB REL.
7 ( 11 ) /01 SIGNAL 1 13
( 11 ) /01 SIGNAL 1

Adr.:7 Adr.:13

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SPARE
SPARE
76
75

( 20 ) /01 SIGNAL 0 ( 20 ) /01 SIGNAL 0


14
10

Adr.:14
Adr.:23

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


MCB CONTROL OFF
CB CLOSE POS.
77
119
( 30 ) /02 MCB CONTROL OFF
( 21 ) /05 CB CLOSE POS. 15
11

Adr.:25
Adr.:11

( 11 ) /01 SIGNAL 1
( 11 ) /01 SIGNAL 1
CB OPEN POS. SEL LOCAL
120 73

( 22 ) /05 CB OPEN POS. ( 26 ) /02 SELECTOR MODE 'LOCAL'


12 16

Adr.:12 Adr.:26

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


10/25 GR FAN A U1

( 97 ) /05 CB INTERLOCKING
( 11 ) /01 SIGNAL 1 CLOSE CMD
CB TEST POS. 130
68 ( 64 ) /05 CLOSE CMD
1
( 23 ) /06 CB- UINIT TEST POS.
17
Adr.:21
Adr.:17

( 11 ) /01 SIGNAL 1
TRIP CMD
( 11 ) /01 SIGNAL 1
117
SPARE
69 ( 68 ) /05 OFF CMD
2
( 20 ) /01 SIGNAL 0
18
Adr.:22

Adr.:18

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


SEL OFF VCB TRIP
71 190

( 38 ) /03 SELECTOR MODE 'OFF' ( 83 ) /07 CB TRIPPED


19 23

Adr.:19 Adr.:126

( 11 ) /01 SIGNAL 1 ( 11 ) /01 SIGNAL 1


REMOTE OPERATION ANY MCB TRIP
72 65
( 30 ) /02 MCB CONTROL OFF 91

( 37 ) /03 SELECTOR MODE 'REMOTE' ( 31 ) /02 MCB SPACE HEATER OFF


( 85 ) /10 ANY MCB TRIPPED
20 ( 32 ) /02 MCB MOTOR CHARG. OFF 24
( 20 ) /01 SIGNAL 0

Adr.:20 Adr.:127

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


11/25 GR FAN A U1

206
( 20 ) /01 SIGNAL 0
( 191 ) /11 ALARM PAGE 1

189
( 86 ) /13 MCB CONTROL OFF
( 94 ) /13 MCB SPACE HEATER OFF ( 67 ) /11
( 98 ) /13 MCB MOTOR CHARG. OFF
( 127 ) /13 CB DISCHARGED
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 20 ) /01 SIGNAL 0

194
( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2

183
( 219 ) /15 49 THERM OVERL ALARM
( 220 ) /15 51 OC IDMT TIME ALARM ( 88 ) /11
( 221 ) /15 50 OC INST DEF TRIP
( 262 ) /15 51N IDMT EF ALARM
( 248 ) /16 64G DEF TRIP
( 249 ) /16 37 LOW LOAD ALARM
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

184
( 269 ) /17 MOTOR START ALARM
( 270 ) /17 MAX NO OF STARTS
( 271 ) /17 LOCKED ROTOR TRIP
( 272 ) /17 UNBALANCE TRIP
( 273 ) /18 27 UNDERVOLTAGE ALARM
( 274 ) /18 59 OVERVOLTAGE ALARM
( 20 ) /01 SIGNAL 0 ( 80 ) /11
( 20 ) /01 SIGNAL 0
193

( 195 ) /11 ALARM PAGE 3


( 20 ) /01 SIGNAL 0

186
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 280 ) LED 3
( 281 ) LED 4
( 282 ) LED 5
( 283 ) LED 6
( 20 ) /01 SIGNAL 0 ( 125 ) /11
( 20 ) /01 SIGNAL 0 195

( 196 ) /11 ALARM PAGE 4


( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


12/25 GR FAN A U1

223
( 127 ) /13 CB DISCHARGED
( 98 ) /13 MCB MOTOR CHARG. OFF
( 83 ) /07 CB TRIPPED
( 81 ) /14 TRIPPING COIL FAIL
( 403 ) /24 CB CLOSING BLOCK
( 221 ) /15 50 OC INST DEF TRIP
( 248 ) /16 64G DEF TRIP
( 181 ) /14 PROTECTION TRIP ( 79 ) /12

224
225
( 120 ) /12 220
( 123 ) /12
( 18 ) /01 SIGNAL 1 RISE DELAY

221
( 271 ) /17 LOCKED ROTOR TRIP ( 95 ) /12
( 272 ) /17 UNBALANCE TRIP
( 285 ) /19 EXTERNAL TRIP 1
( 218 ) /19 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


13/25 GR FAN A U1

CONTROL MCB OFF

red: CONTROL MCB TRIPED


108

101
( 30 ) /02 MCB CONTROL OFF ( 86 ) /13 MCB CONTROL OFF
1
( 17 ) /01 ACKNOLEDGEMENT Page: 1

SPACE HEATER MCB OFF

red: SPACE HTR MCB TRIPED


109

100
( 31 ) /02 MCB SPACE HEATER OFF ( 94 ) /13 MCB SPACE HEATER OFF
2
( 17 ) /01 ACKNOLEDGEMENT Page: 1

MOTOR CHARG MCB OFF

red: MTR CHARG MCB TRIPED


106

103
( 32 ) /02 MCB MOTOR CHARG. OFF ( 98 ) /13 MCB MOTOR CHARG. OFF
3
( 17 ) /01 ACKNOLEDGEMENT Page: 1

63 ch 404

( 27 ) /02 CB DISCHARGED
( 127 ) /13 CB DISCHARGED 188

Time [ms] 20000


( 83 ) /07 CB TRIPPED

CB DISCHARGED / TRIP
( 184 ) /13 CB DISCHARGED
green: CB DISCHARGED

red: CB TRIP
207

( 83 ) /07 CB TRIPPED
4
Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


14/25 GR FAN A U1

TRIPPING COIL

red: TRIPPING COIL FAIL


107

102
( 28 ) /02 TRIPPING COIL FAIL ( 81 ) /14 TRIPPING COIL FAIL
5
( 17 ) /01 ACKNOLEDGEMENT Page: 1

CB ON BLOCKING

red: CB CLOSE BLOCKED


110

( 403 ) /24 CB CLOSING BLOCK


6
Page: 1

Alarm Page 1 of 4

209 red: > Alarm Page 2,3 or4


( 20 ) /01 SIGNAL 0
( 194 ) /11 ALARM PAGE 2 167
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4
( 197 ) /14
( 103 ) /22 DISABLE 46 UNBAL LOAD PR 7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 1
( 113 ) /22 DISABLE 51LR LOCKED PROT
REF Prot.Start/Trip

amber: Protection Start


203 red: Protection Trip
( 169 ) /21 REF PROTECT.TRIP 146

( 183 ) /25 REF PROT. TRIP STORE ( 174 ) /14 159


( 181 ) /14 PROTECTION TRIP
8
( 17 ) /01 ACKNOLEDGEMENT Page: 1

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


15/25 GR FAN A U1

49 Therm.Overl.Alarm

202 red: 49 Therm.Overl.Alarm


( 407 ) /24 49 THERM. OVERLOAD ALARM 144

( 237 ) /25 49 THERM OVERL ALARM ST ( 231 ) /15 160


( 219 ) /15 49 THERM OVERL ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51 OC IDMT Alarm

201 red: 51 OC IDMT Alarm


( 104 ) /23 51 OC IDMT TIME ALARM
147
( 238 ) /25 51OC IDMT ALARM STORE ( 233 ) /15 158
( 220 ) /15 51 OC IDMT TIME ALARM
2
( 17 ) /01 ACKNOLEDGEMENT Page: 2

50 Inst.OC Trip

red: 50 Inst.OC Trip


155
( 105 ) /21 50 OC INST DEF TRIP 181

( 243 ) /25 50 OC INST TRIP STORE ( 234 ) /15 165


( 221 ) /15 50 OC INST DEF TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 2

51N EF IDMT Alarm

red: 51N EF IDMT Alarm


200
( 106 ) /23 51N IDMT EF ALARM 148

( 268 ) /25 51N IDMT EF ALARM STOR ( 261 ) /15 157


( 262 ) /15 51N IDMT EF ALARM
4
( 17 ) /01 ACKNOLEDGEMENT
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


16/25 GR FAN A U1

64G Dir EF TimeTrip

red: 64G Dir EF TimeTrip


199
( 108 ) /21 64G DEF TRIP 175

( 161 ) /25 64G DEF TRIP STORE ( 160 ) /16 213


( 248 ) /16 64G DEF TRIP
5
( 17 ) /01 ACKNOLEDGEMENT Page: 2

37 Low Load Alarm

198 red: 37 Low Load Alarm


( 107 ) /23 37 LOW LOAD ALARM 176
( 129 ) /25 37 LOW LOAD ALARM STO ( 119 ) /16 212
( 249 ) /16 37 LOW LOAD ALARM

( 17 ) /01 ACKNOLEDGEMENT 6
Page: 2

Alarm Page 2 of 4

216 red: > Alarm Page 1,3 or4


( 191 ) /11 ALARM PAGE 1
( 20 ) /01 SIGNAL 0 173
( 195 ) /11 ALARM PAGE 3
( 196 ) /11 ALARM PAGE 4 ( 254 ) /16
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
7
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT Page: 2
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
178

( 181 ) /14 PROTECTION TRIP


8
Page: 2

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


17/25 GR FAN A U1

51MS Start up Alarm

red: 51MS Start up Alarm


154 179
( 404 ) /24 51MS MOTOR START ALARM

( 182 ) /25 MOTOR START ALARM STORE ( 176 ) /17 164


( 269 ) /17 MOTOR START ALARM
1
( 17 ) /01 ACKNOLEDGEMENT Page: 3

66 No.ofStarts Alarm

153 red: 66 No.ofStarts Alarm


( 406 ) /24 66 MAX NO OF STARTS 185

( 186 ) /25 MAX NO STARTS STORE ( 177 ) /17 161


( 270 ) /17 MAX NO OF STARTS
2
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

51LR Lock. RotorTrip

red: 51LR Lock. RotorTrip


152
( 405 ) /21 51 LR LOCKED ROTOR TRIP 182

( 188 ) /25 LOCKED ROTOR TRIP STORE ( 178 ) /17 162


( 271 ) /17 LOCKED ROTOR TRIP
3
( 17 ) /01 ACKNOLEDGEMENT Page: 3

46 Unbalance TRIP

red: 46 Unbalance TRIP


151
( 408 ) /21 46 UNBALANCE TRIP 180

( 190 ) /25 46 UNBALANCE TRIP STOR ( 179 ) /17 163


( 272 ) /17 UNBALANCE TRIP
4
( 17 ) /01 ACKNOLEDGEMENT Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


18/25 GR FAN A U1

27 UnderVoltageAlarm

red: 27 UnderVoltageAlarm
197 171
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 135 ) /18 210
( 138 ) /25 27 UNDERVOLT ALARM STO ( 273 ) /18 27 UNDERVOLTAGE ALARM
5
( 17 ) /01 ACKNOLEDGEMENT Page: 3

59 OverVoltage Alarm

205 red: 59 OverVoltage Alarm


( 411 ) /24 59 OVERVOLTAGE ALARM 172

( 139 ) /25 59 OVERVOLT ALARM STOR ( 136 ) /18 215


( 274 ) /18 59 OVERVOLTAGE ALARM
6
( 17 ) /01 ACKNOLEDGEMENT
Page: 3

Alarm Page 3 of 4

red: > Alarm Page1,2 or4


168
218
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2
( 20 ) /01 SIGNAL 0 ( 275 ) /18 7
( 196 ) /11 ALARM PAGE 4 Page: 3
( 103 ) /22 DISABLE 46 UNBAL LOAD PR
( 109 ) /22 DISABLE 50 OC INST PROT
( 110 ) /22 DISABLE 64G DEF PROT
( 113 ) /22 DISABLE 51LR LOCKED PROT REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
145

( 181 ) /14 PROTECTION TRIP


8
Page: 3

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


19/25 GR FAN A U1

External Trip 1

red: External Trip 1


156 187
( 35 ) /03 EXTERNAL TRIP 1

( 141 ) /19 166


( 150 ) /25 EXTERNAL TRIP 1 STORE ( 285 ) /19 EXTERNAL TRIP 1
1
( 17 ) /01 ACKNOLEDGEMENT Page: 4

External Trip 2

196 red: External Trip 2


( 36 ) /03 EXTERNAL TRIP 2
169
( 143 ) /25 EXTERNAL TRIP 2 STORE
( 142 ) /19
211
( 218 ) /19 EXTERNAL TRIP 2
2
( 17 ) /01 ACKNOLEDGEMENT Page: 4

46 UNBALANCE PROT

red: Unbal Prot Disabled


80

( 103 ) /22 DISABLE 46 UNBAL LOAD PR


3
Page: 4

50 OC INST PROT

red: OCInst Prot Disabled


79

( 109 ) /22 DISABLE 50 OC INST PROT


4
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


20/25 GR FAN A U1

64G DEF PROT

red: D E/F Prot Disabled


78

( 110 ) /22 DISABLE 64G DEF PROT


5
Page: 4

51LR PROT

red: LRotor Prot Disabled


81

( 113 ) /22 DISABLE 51LR LOCKED PROT


6
Page: 4

Alarm Page 4 of 4

red: > Alarm Page1,2 or3


170
217
( 191 ) /11 ALARM PAGE 1
( 194 ) /11 ALARM PAGE 2 ( 284 ) /20
( 195 ) /11 ALARM PAGE 3 7
( 20 ) /01 SIGNAL 0 Page: 4

REF Prot.Start/Trip

amber: Protection Start


red: Protection Trip
177

( 181 ) /14 PROTECTION TRIP


8
Page: 4

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


21/25 GR FAN A U1

( 103 ) /22 DISABLE 46 UNBAL LOAD PR

43 82

( 144 ) /21 RESET UNBALANCE MEMORY


( 408 ) /21 46 UNBALANCE TRIP
2

66
( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 20 ) /01 SIGNAL 0
( 20 ) /01 SIGNAL 0 ( 170 ) /21 EXTERNAL TRIP
104

( 109 ) /22 DISABLE 50 OC INST PROT ( 100 ) /21 PROTECT.TRIP

84 99
( 408 ) /21 46 UNBALANCE TRIP
( 20 ) /01 SIGNAL 0 ( 169 ) /21 REF PROTECT.TRIP
( 105 ) /21 50 OC INST DEF TRIP
( 105 ) /21 50 OC INST DEF TRIP ( 20 ) /01 SIGNAL 0
2 ( 20 ) /01 SIGNAL 0
( 108 ) /21 64G DEF TRIP
( 20 ) /01 SIGNAL 0
( 405 ) /21 51 LR LOCKED ROTOR TRIP

204
( 100 ) /21 PROTECT.TRIP

( 236 ) /25 PROTECTION TRIP STORE

( 111 ) /21
( 110 ) /22 DISABLE 64G DEF PROT

83
214
( 102 ) /21 PROTECTION TRIP

( 108 ) /21 64G DEF TRIP ( 17 ) /01 ACKNOLEDGEMENT ( 101 ) /21 PROTECTION TRIP RESET
2

51
85
( 104 ) /23 51 OC IDMT TIME ALARM ( 71 ) /21

( 113 ) /22 DISABLE 51LR LOCKED PROT


( 112 ) /21

92

( 405 ) /21 51 LR LOCKED ROTOR TRIP

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


22/25 GR FAN A U1

44
56
( 115 ) /22 ( 103 ) /22 DISABLE 46 UNBAL LOAD PR

( 122 ) /22 ENABLE ALL PROT FUs

45
55
( 116 ) /22 ( 109 ) /22 DISABLE 50 OC INST PROT

( 122 ) /22 ENABLE ALL PROT FUs

46
54
( 117 ) /22 ( 110 ) /22 DISABLE 64G DEF PROT

( 122 ) /22 ENABLE ALL PROT FUs

47
53
( 118 ) /22 ( 113 ) /22 DISABLE 51LR LOCKED PROT

( 122 ) /22 ENABLE ALL PROT FUs

48

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


23/25 GR FAN A U1

50

( 104 ) /23 51 OC IDMT TIME ALARM


0

42

( 106 ) /23 51N IDMT EF ALARM


0

( 401 ) /24 MOTOR START

86

( 107 ) /23 37 LOW LOAD ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


24/25 GR FAN A U1

59 ch 403

( 401 ) /24 MOTOR START

( 121 ) /24 MOTORSTART


Time [ms] 43000
40
( 121 ) /24 MOTORSTART 58

( 404 ) /24 51MS MOTOR START ALARM ( 406 ) /24 66 MAX NO OF STARTS

0
0

57
41

( 145 ) /24 RESET TH.-MEMORY ( 124 ) /24 TH. OVERLOAD CB BLOCK


( 407 ) /24 49 THERM. OVERLOAD ALARM
0

98
( 23 ) /06 CB- UINIT TEST POS. ( 35 ) /03 EXTERNAL TRIP 1
( 36 ) /03 EXTERNAL TRIP 2
( 105 ) /21 50 OC INST DEF TRIP
60 ( 108 ) /21 64G DEF TRIP ( 402 ) /24 CB CLOSING BLOCK
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 408 ) /21 46 UNBALANCE TRIP
( 28 ) /02 TRIPPING COIL FAIL
( 410 ) /24 27 UNDERVOLTAGE ALARM ( 20 ) /01 SIGNAL 0
0

( 72 ) /05 CB OPEN POS. DEF


105
( 402 ) /24 CB CLOSING BLOCK ( 403 ) /24 CB CLOSING BLOCK
128
( 17 ) /01 ACKNOLEDGEMENT

( 411 ) /24 59 OVERVOLTAGE ALARM


0

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


25/25 GR FAN A U1

139
BL
( 21 ) /05 CB CLOSE POS. FAULT RECORDER
( 22 ) /05 CB OPEN POS.
( 96 ) /05 CB CLOSE CMD
( 91 ) /05 CB OFF CMD
( 100 ) /21 PROTECT.TRIP
( 104 ) /23 51 OC IDMT TIME ALARM
( 105 ) /21 50 OC INST DEF TRIP
( 106 ) /23 51N IDMT EF ALARM
( 107 ) /23 37 LOW LOAD ALARM
( 108 ) /21 64G DEF TRIP
( 410 ) /24 27 UNDERVOLTAGE ALARM
( 404 ) /24 51MS MOTOR START ALARM
( 405 ) /21 51 LR LOCKED ROTOR TRIP
( 407 ) /24 49 THERM. OVERLOAD ALARM
( 408 ) /21 46 UNBALANCE TRIP
( 411 ) /24 59 OVERVOLTAGE ALARM
( 406 ) /24 66 MAX NO OF STARTS

( 130 ) /25 FAULT REC. OVERFLOW


OVERFLOW

111 ch 411 115 ch 412


( 100 ) /21 PROTECT.TRIP ( 133 ) /25 ( 132 ) /25
START

Time [ms] 5000 Time [ms] 100


191

( 83 ) /07 CB TRIPPED ( 89 ) /25 CB-TRIPPED STORE


( 274 ) /18 59 OVERVOLTAGE ALARM ( 139 ) /25 59 OVERVOLT ALARM STOR
( 285 ) /19 EXTERNAL TRIP 1 ( 150 ) /25 EXTERNAL TRIP 1 STORE
( 102 ) /21 PROTECTION TRIP ( 236 ) /25 PROTECTION TRIP STORE
( 181 ) /14 PROTECTION TRIP ( 183 ) /25 REF PROT. TRIP STORE
( 219 ) /15 49 THERM OVERL ALARM ( 237 ) /25 49 THERM OVERL ALARM ST
( 220 ) /15 51 OC IDMT TIME ALARM ( 238 ) /25 51OC IDMT ALARM STORE
( 221 ) /15 50 OC INST DEF TRIP ( 243 ) /25 50 OC INST TRIP STORE
( 262 ) /15 51N IDMT EF ALARM ( 268 ) /25 51N IDMT EF ALARM STOR
( 248 ) /16 64G DEF TRIP ( 161 ) /25 64G DEF TRIP STORE
( 254 ) /16 ( 129 ) /25 37 LOW LOAD ALARM STO
( 269 ) /17 MOTOR START ALARM ( 182 ) /25 MOTOR START ALARM STORE
( 270 ) /17 MAX NO OF STARTS ( 186 ) /25 MAX NO STARTS STORE
( 271 ) /17 LOCKED ROTOR TRIP ( 188 ) /25 LOCKED ROTOR TRIP STORE
( 272 ) /17 UNBALANCE TRIP ( 190 ) /25 46 UNBALANCE TRIP STOR

( 218 ) /19 EXTERNAL TRIP 2 ( 273 ) /18 27 UNDERVOLTAGE ALARM ( 138 ) /25 27 UNDERVOLT ALARM STO

( 18 ) /01 SIGNAL 1 RISE DELAY ( 143 ) /25 EXTERNAL TRIP 2 STORE

ABB ZSPS - 4688190 Hazem 11kV UNIT 1 SWGR's


PROJECT :-
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

4. COMMISSIONING / HAND OVER REPORTS

ABB
PROJECT :-
SPARES FOR 11KV UNIT SWITCHGEAR (UNIT – 1)

5. IDMT IEC 60255-3 CURVE DEFINITION

ABB

Anda mungkin juga menyukai