Anda di halaman 1dari 33

2001 EDITION

SUPPLEMENT
Special Design
Provisions for
Wind and Seismic

ASD/LRFD
ALLOWABLE STRESS LOAD AND RESISTANCE
DESIGN FACTOR DESIGN

MANUAL FOR ENGINEERED


WOOD CONSTRUCTION

American Forest & Paper Association


American Wood Council
1111 19th Street, NW
Suite 800
American
Washington, DC 20036 Forest &
®
www.awc.org Paper
awcinfo@afandpa.org
Association
America's Forest & Paper People ®
Improving Tomorrow's Environment Today ® ® 06-02 20M American Wood Council

Seismic 2001 Cover.pmd 1 6/9/02, 7:48 PM


2001 EDITION
SUPPLEMENT
Special Design
Provisions for
Wind and Seismic

ASD/LRFD
ALLOWABLE STRESS LOAD AND RESISTANCE
DESIGN FACTOR DESIGN

MANUAL FOR ENGINEERED


WOOD CONSTRUCTION

Copyright © 2001
American Forest & Paper Association, Inc.

Seismic FM draft.pmd 1 5/3/02, 10:35 AM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC

Table of Contents
Chapter/Title Page Chapter/Title Page

1 Designer Flowchart .................................................. 1 4 Lateral Force-Resisting


1.1 Flowchart Systems .............................................................................................. 11
4.1 General
2 General Design Requirements .. 3 4.2 Wood Diaphragms
2.1 General 4.3 Wood Shear Walls
2.2 Terminology
2.3 Notation 5 References ................................................................................. 29

3 Members and Connections ................. 7


3.1 Framing
3.2 Sheathing
3.3 Connections

List of Tables

3.1.1.1 Wall Stud Bending Stress Increase Factors .......... 8 4.2C Nominal Unit Shear Values for Wood-Frame
Diaphragms (Lumber Diaphragms) ........................... 18
3.2A Nominal Uniform Load Capacities, psf,
for Wall Sheathing Resisting Wind Loads ............. 9 4.3.3.4 Shear Capacity Adjustment Factor, Co ................... 20
3.2B Nominal Uniform Load Capacities, psf, 4.3.4 Maximum Shear Wall Aspect Ratios ........................ 21
for Roof Sheathing Resisting Wind Loads ........ 10
4.3A Nominal Unit Shear Values for Wood-Frame
4.2.4 Maximum Diaphragm Aspect Ratios Shear Walls (Wood-based Sheathing) ..................... 25
(Horizontal or Sloped Diaphragms) .......................... 13
4.3B Nominal Unit Shear Values for Wood-Frame
4.2A Nominal Unit Shear Values for Wood-Frame Shear Walls (Gypsum and Cement Plaster) ..... 26
Diaphragms (Blocked Wood Structural Panel
Diaphragms) ............................................................................................ 16 4.3C Nominal Unit Shear Values for Wood-Frame
Shear Walls (Lumber Shear Walls) ............................. 27
4.2B Nominal Unit Shear Values for Wood-Frame
Diaphragms (Unblocked Wood Structural
Panel Diaphragms) .......................................................................... 17

AMERICAN FOREST & PAPER ASSOCIATION

Seismic FM draft.pmd 2 5/3/02, 10:35 AM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 1

DESIGNER
FLOWCHART

1.1 Flowchart 2

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C1 Draft.pmd 1 1/28/02, 4:58 PM


2 DESIGNER FLOWCHART

1.1 Flowchart

Special Design Provisions for


Wind and Seismic Supplement

Select a Trial Design

ASD Design Method LRFD

Design Category = ASD Design Category = LRFD


Allowable Stress Factored Resistance
(Sections 3.0 and 4.0) (Sections 3.0 and 4.0)

Design Capacity ≥
No
Applicable Load
Effect

Yes

Strength Criteria Satisfied

AMERICAN WOOD COUNCIL

Seismic C1 Draft.pmd 2 1/28/02, 4:58 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 3

2
GENERAL
DESIGN
REQUIREMENTS

2.1 General 4
2.2 Terminology 4
2.3 Notation 5

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C2 Draft.pmd 3 5/30/02, 3:18 PM


4 GENERAL DESIGN REQUIREMENTS

2.1 General
2.1.1 Scope provisions permitted by the authority having ju-
risdiction.
The provisions of this Supplement cover materials,
design and construction of wood members, fasteners, and 2.1.2.1 Allowable Stress Design: Allowable stress de-
assemblies to resist wind and seismic forces. sign (ASD) shall be in accordance with the National
Design Specification® (NDS®)for Wood Construction
2.1.2 Design Methods (ANSI/AF&PA NDS-2001), its supplements, and provi-
sions of this Supplement.
Engineered design of wood structures to resist wind 2.1.2.2 Strength Design: Load and resistance factor
or seismic forces shall be by one of the methods described design (LRFD) of wood structures shall be in accordance
in Section 2.1.2.1 and 2.1.2.2. with the Load and Resistance Factor Standard for Engi-
neered Wood Construction (AF&PA/ASCE 16-95), its
Exception: Wood structures shall be permitted supplements, and provisions of this Supplement.
to be constructed in accordance with prescriptive

2.2 Terminology
ALLOWABLE STRESS DESIGN A method of pro- under lateral load is greater than two times the average
portioning structural members such that elastically deflection of adjoining vertical elements of the lateral
computed stresses produced in the members by nominal force-resisting system of the associated story under equiva-
loads does not exceed specific allowable stresses (also lent tributary lateral load.
called working stress design).
DIAPHRAGM, RIGID A diaphragm is rigid for the pur-
BOUNDARY ELEMENT Diaphragm and shear wall pose of distribution of story shear and torsional moment
boundary members to which sheathing transfers forces. when the computed maximum in-plane deflection of the
Boundary elements include chords and collectors at dia- diaphragm itself under lateral load is less than or equal to
phragm and shear wall perimeters, interior openings, two times the average deflection of adjoining vertical el-
discontinuities and re-entrant corners. ements of the lateral force-resisting system of the
associated story under equivalent tributary lateral load.
CHORD A boundary element perpendicular to the ap-
For analysis purposes, it can be assumed that a rigid dia-
plied load that is assumed to resist axial stresses due to
phragm distributes story shear and torsional moment into
the induced moment.
lines of shear walls by the relative lateral stiffness of the
COLLECTOR A diaphragm or shear wall element par- shear walls.
allel and in line with the applied force that collects and
transfers diaphragm shear forces to the vertical elements [For the first iteration, an arbitrary load is ap-
of the lateral force-resisting system and/or distributes plied to each line of shear walls to determine the
forces withing the diaphragm. relative stiffness of the lines of walls. Once the
DIAPHRAGM A roof, floor or other membrane bracing relative stiffnesses of the wall lines have been de-
system acting to transmit lateral forces to the vertical re- termined, the applied lateral load is distributed
sisting elements. When the term “diaphragm” is used, it proportionally. The shear walls are redesigned
includes horizontal bracing systems. and the lateral stiffness is recalculated and the
applied load is re-apportioned. This is continued
DIAPHRAGM, BLOCKED A diaphragm in which all until convergence.]
adjacent sheathing edges are fastened to either common
framing or common blocking.
DIAPHRAGM, UNBLOCKED A diaphragm that has
DIAPHRAGM, FLEXIBLE A diaphragm is flexible for edge nailing at supporting members only. Blocking be-
the purpose of distribution of story shear when the com- tween supporting structural members at panel edges is not
puted maximum in-plane deflection of the diaphragm itself

AMERICAN WOOD COUNCIL

Seismic C2 Draft.pmd 4 5/30/02, 3:18 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 5

included. Diaphragm panels are field nailed to support- PERFORATED SHEAR WALL SEGMENT A sec-
ing members. tion of a perforated shear wall with full height sheathing
DIAPHRAGM BOUNDARY A location where shear is which meets the requirements for maximum aspect ratio
transferred into or out of the diaphragm sheathing. Trans- in Section 4.3.4.
fer is either to a boundary element or to another PLYWOOD A wood structural panel comprised of plies 2
force-resisting element. of wood veneer arranged in cross-aligned layers. The
FIBERBOARD A fibrous, homogeneous panel made plies are bonded with an adhesive that cures on applica-

GENERAL DESIGN REQUIREMENTS


from lignocellulosic fibers (usually wood or cane) and tion of heat and pressure.
having a density of less than 31 pounds per cubic foot REQUIRED STRENGTH Strength of a member, cross
(497 kg/m3) but more than 10 pounds per cubic foot (160 section, or connection required to resist factored loads or
kg/m3). related internal moments and forces.
HARDBOARD A fibrous-felted, homogeneous panel RESISTANCE FACTOR A factor that accounts for
made from lignocellulosic fibers consolidated under heat unavoidable deviations of the actual strength from the
and pressure in a hot press to a density not less than 31 nominal value and the manner and consequences of fail-
pounds per cubic foot. ure.
LATERAL STIFFNESS The inverse of the deforma- SEISMIC DESIGN CATEGORY A classification as-
tion of shear walls under an applied unit load, or the force signed to a structure based on its Seismic Use Group and
required to deform a shear wall a unit distance. the severity of the design earthquake ground motion at
NOMINAL STRENGTH Strength of a member, cross the site.
section, or connection before application of any strength SHEAR WALL A wall designed to resist lateral forces
reduction factors. parallel to the plane of a wall.
ORIENTED STRAND BOARD A mat-formed wood SHEAR WALL LINE A series of shear walls in a line at
structural panel product composed of thin rectangular a given story level.
wood strands or wafers arranged in oriented layers and
SUBDIAPHRAGM A portion of a larger wood dia-
bonded with waterproof adhesive.
phragm designed to anchor and transfer local forces to
PARTICLEBOARD A generic term for a panel prima- primary diaphragm struts and the main diaphragm.
rily composed of cellulosic materials (usually wood),
TIE-DOWN (HOLD-DOWN) A device used to resist
generally in the form of discrete pieces or particles, as
uplift of the chords of shear walls.
distinguished from fibers. The cellulosic material is com-
bined with synthetic resin or other suitable bonding system WOOD STRUCTURAL PANEL A panel manufactured
by a process in which the interparticle bond is created by from veneers; or wood strands or wafers; or a combina-
the bonding system under heat and pressure. tion of veneer and wood strands or wafers; bonded
together with waterproof synthetic resins or other suit-
PERFORATED SHEAR WALL A sheathed wall with
able bonding systems. Examples of wood structural
openings, but which has not been specifically designed
panels are plywood, oriented strand board (OSB), or com-
and detailed for force transfer around wall openings.
posite panels.

2.3 Notation
A = Area of chord cross-section, in.2 E = Modulus of elasticity of end posts, psi
2
A = Area of end post cross-section, in. E = Modulus of elasticity of diaphragm chords, psi
C = Compression chord force, lbs. G = Specific gravity
Co = Shear capacity adjustment factor from Table Ga = Apparent shear wall shear stiffness from nail
4.3.3.4. slip and panel shear deformation, kips/in. (from

Column A, Table 4.3).

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C2 Draft.pmd 5 5/30/02, 3:18 PM


6 GENERAL DESIGN REQUIREMENTS

Ga = Apparent diaphragm shear stiffness from nail 2. The maximum clear height from top of
slip and panel shear deformation, kips/in. (from diaphragm to bottom of diaphragm framing

Column A, Table 4.2). above.


Gac = Combined apparent shear wall shear stiffness t = Uniform uplift force, lbs./ft.
of two-sided shear wall, kips/in. ν = Induced unit shear, lbs./ft.

Ga1 = Apparent shear wall shear stiffness for side 1, νs = Nominal unit shear capacity for seismic design,
kips/in. (from Column A, Table 4.3). lbs./ft.
Ga2 = Apparent shear wall shear stiffness for side 2, νmax = Maximum induced unit shear force, lbs./ft.

kips/in. (from Column A, Table 4.3). νsc = Combined nominal unit shear capacity of two-
Kmin = Minimum ratio of v1/Ga1 or v2/Ga2 sided shear wall for seismic design, lbs./ft.
L = The dimension of a diaphragm perpendicular to νs1 = Nominal unit shear capacity for side 1, lbs./ft.

the direction of application of force. For open- (from Column A, Table 4.3).
front structures, L is the length from the edge of νs2 = Nominal unit shear capacity for side 2, lbs./ft.
the diaphragm at the open front to the vertical (from Column A, Table 4.3).

resisting elements parallel to the direction of νw = Nominal unit shear capacity for wind design,
the applied force. lbs./ft
Lc = The length of the cantilever for a cantilever νwc = Combined nominal unit shear capacity of two-

diaphragm, ft. (see figure 4.2.5.2) sided shear wall for wind design, lbs./ft.
ΣLi = Sum of perforated shear wall segment lengths, x = Distance from chord splice to nearest support,
ft. in.
R = Response modification coefficient ∆c = Diaphragm chord splice slip at the induced unit

T = Tension chord force, lbs. shear in diaphragm, in.


V = Induced shear force in perforated shear wall, ∆a = Total vertical elongation of wall anchorage
lbs. system (including fastener slip, device

W = Diaphragm width, ft. elongation, rod elongation, etc) at the induced


W = The width of a diaphragm in the direction of unit shear in the shear wall, in.
application of force measured as the sheathed δdia = Maximum diaphragm deflection determined by

dimension of the diaphragm. elastic analysis, in.


b = The length of a shear wall or shearwall segment δsw = Maximum shear wall deflection determined by
measured as the sheathed dimension of the elastic analysis, in.

shear wall. φb = Sheathing resistance factor for out of plane


bs = Shear wall length for determining apect ratio. bending
For perforated shearwalls, use the minimum φD = Sheathing resistance factor for in-plane shear

shearwall segment length included in the Li , ft. of shearwalls and diaphragms


h = The height of a shear wall or shearwall segment Ω0 = System overstrength factor
measured as:

1. The maximum clear height from top of


foundation to bottom of diaphragm framing
above or

AMERICAN WOOD COUNCIL

Seismic C2 Draft.pmd 6 5/30/02, 3:18 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 7

MEMBERS AND
3
CONNECTIONS

3.1 Framing 8
3.2 Sheathing 8
3.3 Connections 10

Table 3.1.1.1 Wall Stud Bending Stress Increase Factors ..... 8


Table 3.2A Nominal Uniform Load Capacities, psf, for
Wall Sheathing Resisting Wind Loads .............. 9
Table 3.2B Nominal Uniform Load Capacities, psf, for
Roof Sheathing Resisting Wind Loads ........... 10

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C3 Draft.pmd 7 5/1/02, 7:46 PM


8 MEMBERS AND CONNECTIONS

3.1 Framing
3.1.1 Wall Framing 3.1.2 Floor Framing

In addition to gravity loads, wall framing shall be In addition to gravity loads, floor framing shall be
designed to resist induced wind and seismic forces. The designed to resist induced wind and seismic forces. The
framing shall be designed using methods referenced in framing shall be designed using methods referenced in
2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for
strength design (LRFD). strength design (LRFD).
3.1.1.1 Wall Stud Bending Stress Increase: The bend-
ing stress for sawn lumber wood studs resisting out of 3.1.3 Roof Framing
plane wind loads shall be permitted to be increased by the
factors in Table 3.1.1.1, in lieu of the 1.15 repetitive mem- In addition to gravity loads, roof framing shall be de-
ber factor, to take into consideration the load sharing and signed to resist induced wind and seismic forces. The
composite action provided by wood structural panel framing shall be designed using methods referenced in
sheathing. The factor applies when studs are designed for 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2 for
bending, spaced no more than 16 inches on center, cov- strength design (LRFD).
ered on the inside with a minimum of ½-inch gypsum
wallboard, and sheathed on the exterior with a minimum
of 3/8-inch wood structural panel sheathing that is attached
to the studs using a minimum of 8d common nails spaced a
maximum of 6 inches o.c. at panel edges and 12 inches o.c.
at intermediate framing members.

Table 3.1.1.1 Wall Stud Bending


Stress Increase Factors

Stud Size System Factor


2x4 1.5
2x6 1.4
2x8 1.3
2x10 1.2
2x12 1.15

3.2 Sheathing
3.2.1 Wall Sheathing blies to resist lateral forces shall be designed in accor-
dance with 4.3.
Exterior wall sheathing and its fasteners shall be ca-
pable of resisting and transferring out of plane wind loads 3.2.2 Floor Sheathing
to the wall framing. Maximum spans and nominal uni-
form load capacities for wall sheathing materials are given Floor sheathing shall be capable of resisting and trans-
in Table 3.2A. The ASD allowable uniform load capaci- ferring gravity loads to the floor framing. Sheathing used
ties to be used for wind design shall be determined by in diaphragm assemblies to resist lateral forces shall be
dividing the nominal uniform load capacities by a safety designed in accordance with 4.2.
factor of 1.6. The LRFD factored uniform load capacities
to be used for wind design shall be determined by multi-
plying the nominal uniform load capacities by a resistance
factor, φb, of 0.85. Sheathing used in shear wall assem-

AMERICAN WOOD COUNCIL

Seismic C3 Draft.pmd 8 5/1/02, 7:46 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 9

Table 3.2A Nominal Uniform Load Capacities, psf, for Wall Sheathing Resisting
Wind Loads1

Sheathing Type3 Span Rating or Grade Minimum


Thickness Sheathing Long Dimension Orientation:
(in.)
Perpendicular to Supports Parallel to Supports

Maximum
Stud Spacing
Actual Stud
Spacing (in.)
Maximum
Stud Spacing
Actual Stud
Spacing (in.)
3
(in.) (in.)
12 16 24 12 16 24

MEMBERS AND CONNECTIONS


Nominal Uniform Nominal Uniform
Loads (psf) Loads (psf)

Wood Structural Panels4 24/0 3/8 24 425 240 105 24 90 50 –


(Sheathing Grades, C-C, 24/16 7/16 24 540 305 135 24 110 60 252
C-D, C-C Plugged, OSB) 32/16 15/32 24 625 355 155 24 155 90 402
40/20 19/32 24 950 595 265 24 255 145 652
48/24 23/32 24 1160 805 360 24 380 215 902

Particleboard Sheathing 3/8 16 (contact 16 (contact


(M-S Exterior Glue) 1/2 16 manufacturer) 16 manufacturer)

Particleboard Panel 5/8 16 (contact 16 (contact


Siding 3/4 24 manufacturer) 24 manufacturer)
(M-S Exterior Glue)

Hardboard Siding Lap Siding 7/16 16 460 260 - - - - -


(Direct to Studs) Shiplap Edge Panel Siding 7/16 24 460 260 115 24 460 260 115
Square Edge Panel Siding 7/16 24 460 260 115 24 460 260 115

Cellulosic Fiberboard Regular 1/2 - - - - 16 90 50 -


Sheathing Structural 1/2 - - - - 16 135 75 -
Structural 25/32 - - - - 16 165 90 -
1. Nominal capacities shall be adjusted in accordance with Section 3.2.1 to determine ASD uniform load capacity and LRFD uniform resistances.
2. Sheathing shall be OSB or plywood with 4 or more plies.
3. Wood structural panels shall conform to the requirements for its type in DOC PS 1 or PS2. Particleboard sheathing shall conform to ANSI A208.1.
Hardboard panel and siding shall conform to the requirements of AHA A135.5 or AHA A135.4 as applicable. Cellulosic fiberboard sheathing shall
conform to AHA A194.1 or ASTM C208.
4. Tabulated values are for maximum bending loads from wind. Loads are limited by bending or shear stress assuming a 2-span continuous condition.
For more information, see the ASD Wood Structural Panels Supplement.

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C3 Draft.pmd 9 5/1/02, 7:46 PM

December 15, 2001


10 MEMBERS AND CONNECTIONS

3.2.3 Roof Sheathing determined by dividing the nominal uniform load capaci-
ties by a safety factor of 1.6. The LRFD factored uniform
Roof sheathing and its fasteners shall be capable of load capacities to be used for wind design shall be deter-
resisting and transferring out of plane wind and gravity mined by multiplying the nominal uniform load capacities
loads to the roof framing. Maximum spans and nominal by a resistance factor, φb, of 0.85. Sheathing used in dia-
uniform load capacities for roof sheathing materials are phragm assemblies to resist lateral forces shall be designed
given in Table 3.2B. The ASD allowable uniform load in accordance with 4.2.
capacities to be used for out of plane wind design shall be

Table 3.2B Nominal Uniform Load Capacities, psf, for Roof Sheathing Resisting
Wind Loads1

Sheathing Type Span Rating or Grade Minimum Sheathing Long Dimension Applied
Thickness Perpendicular to Supports
(in.)
Rafter/Truss Spacing (in.)

12 16 19.2 24

Nominal Uniform Loads (psf)

Wood Structural Panels2,3 24/0 3/8 425 240 165 105


(Sheathing Grades, C-C, 24/16 7/16 540 305 210 135
C-D, C-C Plugged, OSB) 32/16 15/32 625 355 245 155
40/20 19/32 950 595 415 265
48/24 23/32 1160 805 560 360
Wood Structural Panels2,3 16 o.c. 19/32 705 395 275 175
(Single Floor Grades, 20 o.c. 19/32 815 455 320 205
Underlayment, C-C 24 o.c. 23/32 1085 610 425 270
Plugged) 32 o.c. 7/8 1390 830 575 370
48 o.c. 1-3/32 1790 1295 1060 680
1. Nominal capacities shall be adjusted in accordance with Section 3.2.3 to determine ASD uniform load capacity and
LRFD uniform resistances.
2. Wood structural panels shall conform to the requirements for its type in DOC PS 1 or PS2.
3. Tabulated values are for maximum bending loads from wind. Loads are limited by bending or shear stress assuming a 2-
span continuous condition. For more information, see the ASD Wood Structural Panels Supplement.

3.3 Connections
December 15, 2001

3.3.1 Connections

Connections resisting induced wind and seismic forces


shall be designed in accordance with methods referenced
in 2.1.2.1 for allowable stress design (ASD) and 2.1.2.2
for strength design (LRFD).

AMERICAN WOOD COUNCIL

Seismic C3 Draft.pmd 10 5/1/02, 7:46 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 11

LATERAL
FORCE-
4
RESISTING
SYSTEMS

4.1 General 12
4.2 Wood Diaphragms 13
4.3 Wood Shear Walls 19

Table 4.2.4 Maximum Diaphragm Aspect Ratios


(Horizontal or Sloped Diaphragms) ............ 13
Table 4.2A-C Nominal Unit Shear Values for Wood-
Frame Diaphragms:
A = Blocked Diaphragms ........................... 16
B = Unblocked Diaphragms ...................... 17
C = Lumber Diaphragms .......................... 18
Table 4.3.3.4 Shear Capacity Adjustment Factor, Co ....... 20
Table 4.3.4 Maximum Shear Wall Aspect Ratios ........... 21
Table 4.3A-C Nominal Unit Shear Values for Wood-
Frame Shear Walls:
A = Wood-based Sheathing ........................ 25
B = Gypsum and Cement Plaster ............. 26
C = Lumber Shear Walls ........................... 27

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C4 Draft.pmd 11 6/11/02, 6:35 PM


12 LATERAL FORCE-RESISTING SYSTEMS

4.1 General
4.1.1 Design Requirements 4.1.5 Wood Systems Resisting
Horizontal Seismic Forces
The proportioning, design, and detailing of engineered Contributed by Masonry and
wood systems, members, and connections in lateral force- Concrete
resisting systems shall be in accordance with methods
referenced in 2.1.2 and provisions in this Chapter. Wood shear walls, diaphragms, trusses and other wood
A continuous load path, or paths, with adequate assemblies shall not be used to resist horizontal seismic
strength and stiffness shall be provided to transfer all forces forces contributed by masonry or concrete construction in
from the point of application to the final point of resis- structures over one story in height.
tance. Exceptions:
1. Wood floor and roof assemblies shall be per-
4.1.2 Shear Capacity mitted to be used in diaphragms and horizontal
trusses to resist horizontal seismic forces (in-
Nominal shear capacities of diaphragms and shear cluding those due to masonry veneer, fireplaces,
walls are provided for reference assemblies in Tables 4.2 and chimneys) provided such forces do not re-
and 4.3, respectively. Alternatively, shear capacity of dia- sult in torsional force distribution through the
phragms and shear walls shall be permitted to be calculated truss or diaphragm.
by principles of mechanics using values of fastener 2. Vertical wood structural panel sheathed shear
strength and sheathing shear capacity. walls shall be permitted to be used to provide
resistance to seismic forces in two-story struc-
4.1.3 Deformation Requirements tures of masonry or concrete construction,
provided the following requirements are met:
Deformation of connections within and between struc- a. Story-to-story wall heights shall not ex-
tural elements shall be considered in design such that the ceed 12 feet.
deformation of each element and connection comprising b. Diaphragms shall not be considered to
the lateral force-resisting system is compatible with the transmit lateral forces by torsional force dis-
deformations of the other lateral force-resisting elements tribution or cantilever past the outermost
and connections and with the overall system. supporting shear wall.
c. Combined deflections of diaphragms and
4.1.4 Boundary Elements shear walls shall not permit story drift of
supported masonry or concrete walls to ex-
Shear wall and diaphragm boundary elements shall ceed 0.7% of the story height.
be provided to transfer the design tension and compres- d. Wood structural panel sheathing in dia-
sion forces. Diaphragm and shear wall sheathing shall not phragms shall have all unsupported edges
be used to splice boundary elements. Diaphragm chords blocked. Wood structural panel sheathing
and collectors shall be placed in, or in contact with, the for both stories of shear walls shall have
plane of the diaphragm framing unless it can be demon- all unsupported edges blocked and, for the
strated that the moments, shears, and deflections, lower story, shall have a minimum thick-
considering eccentricities resulting from other configura- ness of 15/32 inch.
tions, can be tolerated without exceeding the framing e. There shall be no out-of-plane horizontal
capacity and drift limits. offsets between the first and second sto-
ries of wood structural panel shear walls.

4.1.6 Toenails

In seismic categories D, E, and F, toenails shall not be


used to transfer lateral forces greater than 150 pounds per
lineal foot from diaphragms to shearwalls, drag struts to
other elements, or from shear walls to other elements.

AMERICAN WOOD COUNCIL

Seismic C4 Draft.pmd 12 6/11/02, 6:35 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 13

4.2 Wood Diaphragms


4.2.1 Application Requirements Alternatively, for wood structural panel diaphragms,
deflection is permitted to be calculated using a rational
Wood diaphragms are permitted to be used to resist analysis where apparent shear stiffness accounts for panel
horizontal forces provided the deflection in the plane of shear deformation and non-linear nail slip in the sheath-
the diaphragm, as determined by calculations, tests, or ing to framing connection.
analogies drawn therefrom, does not exceed the permis-
sible deflection of attached load distributing or resisting 4.2.3 Shear Capacities
elements. Connections and blocking shall extend into the
diaphragm a sufficient distance to develop the force trans- The nominal unit shear capacities for seismic design 4
ferred into the diaphragm. are provided in Column A of Tables 4.2A, B, and C and
for wind design in Column B of Tables 4.2A, B, and C.

LATERAL FORCE-RESISTING SYSTEMS


4.2.2 Deflection The ASD allowable unit shear capacity shall be deter-
mined by dividing the nominal unit shear capacity by a
Permissible deflection shall be that deflection up to safety factor of 2.0. No further increases shall be permit-
which the diaphragm and any attached load distributing ted. The LRFD factored unit resistance shall be
or resisting element will maintain its structural integrity determined by multiplying the nominal unit shear capac-
under design load conditions, such that the resisting ele- ity by a resistance factor, φD, of 0.65.
ment will continue to support design loads without danger
to occupants of the structure. 4.2.4 Diaphragm Aspect Ratios
Calculations of diaphragm deflection shall account
for bending and shear deflections, fastener deformation, Size and shape of diaphragms shall be limited to the
chord splice slip, and other contributing sources of de- aspect ratios in Table 4.2.4.
flection.
The midspan diaphragm deflection, δdia , is permitted Table 4.2.4 Maximum Diaphragm
to be calculated by use of the following equation: Aspect Ratios
(Horizontal or Sloped Diaphragms)

δdia =
5νL
3
+
0.25νL
+
∑ ( x∆c ) (4.2-1)
8EAW 1000 Ga 2W Diaphragm Maximum
Sheathing Type L/W Ratio
where: Wood structural panel, unblocked 3:1
E = Modulus of elasticity of diaphragm chords, psi Wood structural panel, blocked 4:1
A = Area of chord cross-section, in.2
Single-layer straight lumber sheathing 2:1
Single-layer diagonal lumber sheathing 3:1
Ga = Apparent diaphragm shear stiffness from nail
Double-layer diagonal lumber sheathing 4:1
slip and panel shear deformation, kips/in. (from
Column A, Table 4.2) 4.2.5 Horizontal Distribution of
L = Diaphragm length, ft. Shear
ν = Induced unit shear in diaphragm, lbs./ft.
W = Diaphragm width, ft.
Diaphragms shall be defined as rigid or flexible for
the purposes of distributing shear loads and designing for
x = Distance from chord splice to nearest support,
torsional moments. When a diaphragm is defined as flex-
in. ible, the diaphragm shear forces shall be distributed to the
∆c = Diaphragm chord splice slip at the induced unit vertical resisting elements based on tributary area. When
shear in diaphragm, in. a diaphragm is defined as rigid, the diaphragm shear forces
shall be distributed based on the relative lateral stiffnesses
δdia = Maximum diaphragm deflection determined by
of the vertical resisting elements for the story below.
elastic analysis, in. 4.2.5.1 Torsional Irregularity: Structures with rigid
wood diaphragms shall be considered as torsionally ir-

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C4 Draft.pmd 13 6/11/02, 6:35 PM


14 LATERAL FORCE-RESISTING SYSTEMS

regular when the maximum story drift, computed includ- Figure 4.2.5.2 Cantilevered Diaphragm
ing accidental torsion, at one end of the structure is more
than 1.2 times the average of the story drifts at the two Shear Walls
ends of the structure. Where torsional irregularity exists,
diaphragms shall meet the following requirements:
1. The diaphragm conforms to 4.2.7.1 - 4.2.7.3. Force

2. The L/W ratio of the diaphragm is less than Cantilevered


1:1 for one-story structures or 1:1½ for struc- Diaphragm

tures over one story in height.


Lc

Exception: Where calculations show that diap-


W
hragm deflections can be tolerated, the length, L,
Plan View
shall be permitted to be increased to an L/W ratio
not greater than 1½:1 when sheathed in conform-
ance with 4.2.7.1 or to 1:1 when sheathed in 4.2.6 Construction Requirements
conformance with 4.2.7.2 or 4.2.7.3.
4.2.6.1 Framing Requirements: Diaphragm boundary
4.2.5.1.1 Open Front Structures: Open front struc- elements shall be provided to transmit the design tension,
tures utilizing rigid wood diaphragms to distribute shear compression and shear forces. Diaphragm sheathing shall
forces through torsion shall be permitted provided: not be used to splice boundary elements. Diaphragm
1. The diaphragm length, L, (normal to the open chords and collectors shall be placed in, or in contact with,
side) does not exceed 25 feet. the plane of the diaphragm framing unless it can be dem-
2. The L/W ratio (as shown in Figure 4.2.5.1) onstrated that the moments, shears, and deflections,
of the diaphragm is less than 1:1 for one-story considering eccentricities resulting from other configura-
structures or 1:1½ for structures over one story tions, can be tolerated without exceeding the framing
in height. capacity and drift limits.
4.2.6.2 Sheathing: Diaphragms shall be sheathed with
Exception: Where calculations show that diap- approved materials. Details on sheathing types and thick-
hragm deflections can be tolerated, the length, L, nesses for commonly used floor, roof and ceiling
(normal to the open side) shall be permitted to be diaphragm assemblies are provided in 4.2.7 and Tables
increased to an L/W ratio not greater than 1½:1 4.2A, B, and C.
when sheathed in conformance with 4.2.7.1 or 4.2.6.3 Fasteners: Sheathing shall be attached to fram-
4.2.7.3 or to 1:1 when sheathed in conformance ing using approved fasteners and/or adhesives. Nails or
with 4.2.7.2. other approved sheathing connectors shall be driven flush
with the surface of the sheathing. Details on type, size,
Figure 4.2.5.1 Open Front Building and spacing of mechanical fasteners for typical floor, roof,
and ceiling diaphragm assemblies are provided in 4.2.7
Shear Walls and Tables 4.2A, B, and C.

4.2.7 Diaphragm Assemblies


Force W
L
Open Front 4.2.7.1 Wood Structural Panel Diaphragms: Dia-
on Building
phragms sheathed with wood structural panel sheathing
Plan View
shall be permitted to be used to resist seismic and wind
forces. Wood structural panel sheathing used for dia-
4.2.5.2 Cantilevered Diaphragms: Rigid wood dia- phragms that are part of the lateral force-resisting system
phragms shall be permitted to cantilever past the outermost shall be applied directly to the framing members.
supporting shear wall (or other vertical resisting element)
a distance, Lc, of not more than 25 feet or two thirds of the Exception: Wood structural panel sheathing in a
diaphragm width, W, whichever is smaller. Figure 4.2.5.2 diaphragm is permitted to be fastened over solid
illustrates the dimensions of Lc and W for a cantilevered lumber planking or laminated decking provided
diaphragm. the panel joints and lumber planking or laminated

AMERICAN WOOD COUNCIL

Seismic C4 Draft.pmd 14 6/28/02, 5:12 AM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 15

decking joints do not coincide. In addition, adja- nominal sheathing boards or 2-inch thick nominal lumber
cent panel edges shall be fastened to a common laid at an angle of approximately 45° to the supports. End
member and fasteners shall not be spaced less than joints in adjacent boards shall be separated by at least one
3/8 inches from the edges of panels or joints in joist space and there shall be at least two boards between
the substrate. joints on the same support. Nailing of diagonally sheathed
lumber diaphragms shall be in accordance with Table 4.2C.
Where diaphragms are designated as blocked, all joints Single diagonally sheathed lumber diaphragms shall be
in sheathing shall occur over and be fastened to common permitted to consist of 2x nominal lumber (1½ inches
framing members. The size and spacing of fasteners at thick) where the supports are not less than 3x nominal
wood diaphragm boundaries, panel edges, and intermedi- (2½ inches thick) in width or 4x nominal (3½ inches deep)
ate supports shall be as prescribed in Tables 4.2A and B. in depth.
The diaphragm shall be constructed as follows: 4.2.7.3 Diaphragms Diagonally Sheathed with 4
1. Panels not less than 4 ft. x 8 ft. except at ends Double-Layer of Lumber: Double diagonally sheathed
where reduced widths are permitted. lumber diaphragms are permitted to be used to resist seis-

LATERAL FORCE-RESISTING SYSTEMS


2. Nails spaced not less than 3/8 inches from edges mic and wind forces. Double diagonally sheathed lumber
and ends of panels and framing. Maximum nail diaphragms shall be constructed of two layers of diagonal
spacing of 6 inches along intermediate framing sheathing boards laid perpendicular to each other on the
members when supports are spaced 48 inches same face of the supporting members. Each chord shall
o.c. Maximum nail spacing along intermediate be considered as a beam with uniform load per foot equal
framing of 12 inches for other conditions. to 50% of the unit shear due to diaphragm action. The
3. 2x nominal or wider framing at adjoining load shall be assumed as acting normal to the chord in the
panel edges except that 3x nominal or wider plane of the diaphragm in either direction. Nailing of di-
framing and staggered nailing are required agonally sheathed lumber diaphragms shall be in
where: accordance with Table 4.2C.
a) nails are spaced 2 inches o.c. or 2 ½ 4.2.7.4 Diaphragms Horizontally Sheathed with
inches o.c., or Single-Layer of Lumber: Horizontally sheathed lumber
b) 10d nails having penetration into fram- diaphragms are permitted to be used to resist seismic and
ing of more than 1-1/2 in. are spaced 3 wind forces. Horizontally sheathed lumber diaphragms
inches o.c. or less shall be constructed of minimum 1-inch thick nominal
4. Wood structural panels shall conform to the sheathing boards or minimum 2-inch thick nominal lum-
requirements for its type in DOC PS1 or PS2. ber laid perpendicular to the supports. End joints in
4.2.7.2 Diaphragms Diagonally Sheathed with Single- adjacent boards shall be separated by at least one joist
Layer of Lumber: Single diagonally sheathed lumber space and there shall be at least two boards between joints
diaphragms are permitted to be used to resist seismic and on the same support. Nailing of horizontally sheathed
wind forces. Single diagonally sheathed lumber dia- lumber diaphragms shall be in accordance with Table 4.2C.
phragms shall be constructed of minimum 1-inch thick

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C4 Draft.pmd 15 6/11/02, 6:35 PM


16

Table 4.2A Nominal Unit Shear Values for Wood-Frame Diaphragms

Blocked Wood Structural Panel Diaphragmsa,b


A B
SEISMIC WIND
Nail Spacing (in.) at Diaphragm Boundries (All Cases), at
Nail Spacing (in.) at Diaphragm Boundries (All Cases), at Continuous Panel Edges Continuous Panel Edges Parallel to Load (Cases 3 & 4),
Parallel to Load (Cases 3 & 4), and at All Panel Edges (Cases 5 & 6) and at All Panel Edges (Cases 5 & 6)
6 4 2.5 2 6 4 2.5 2
Minimum Minimum Minimum
Fastener Nominal Nominal Nail Spacing (in.) at Other Panel Edges
Common Nail Spacing (in.) at Other Panel Edges (Cases 1, 2, 3, & 4) (Cases 1, 2, 3, & 4)
Sheathing Grade Penetration in Panel Framing
Nail Size 6 6 4 3 6 6 4 3
Framing Thickness Width
(inches) (inches) (inches) v_s G_a v_s G_a v_s G_a v_s G_a v_w v_w v_w v_w
(plf) (kips/in) (plf) (kips/in) (plf) (kips/in) (plf) (kips/in) (plf) (plf) (plf) (plf)
2 370 15.0 500 8.5 750 12.0 840 20.0 520 700 1050 1175
6d 1 1/4 5/16
3 420 12.0 560 7.0 840 9.5 950 17.0 590 785 1175 1330
2 540 14.0 720 9.0 1060 13.0 1200 21.0 755 1010 1485 1680
Structural Ic 8d 1 3/8 3/8
3 600 12.0 800 7.5 1200 10.0 1350 18.0 840 1120 1680 1890
2 640 24.0 850 15.0 1280 20.0 1460 31.0 895 1190 1790 2045
10d 1 1/2 15/32
3 720 20.0 960 12.0 1440 16.0 1640 26.0 1010 1345 2015 2295
2 340 15.0 450 9.0 670 13.0 760 21.0 475 630 940 1065
5/16
3 380 12.0 500 7.0 760 10.0 860 17.0 530 700 1065 1205
6d 1 1/4
2 370 13.0 500 7.0 750 10.0 840 18.0 520 700 1050 1175
3/8
3 420 10.0 560 5.5 840 8.5 950 14.0 590 785 1175 1330
2 480 15.0 640 9.5 960 13.0 1090 21.0 670 895 1345 1525
3/8
3 540 12.0 720 7.5 1080 11.0 1220 18.0 755 1010 1510 1710
Sheathing and Single- 2 510 14.0 680 8.5 1010 12.0 1150 20.0 715 950 1415 1610
8d 1 3/8 7/16
Floorc 3 570 11.0 760 7.0 1140 10.0 1290 17.0 800 1065 1595 1805
2 540 13.0 720 7.5 1060 11.0 1200 19.0 755 1010 1485 1680
15/32
3 600 10.0 800 6.0 1200 9.0 1350 15.0 840 1120 1680 1890
2 580 25.0 770 15.0 1150 21.0 1310 33.0 810 1080 1610 1835
15/32
3 650 21.0 860 12.0 1300 17.0 1470 28.0 910 1205 1820 2060
10d 1 1/2
2 640 21.0 850 13.0 1280 18.0 1460 28.0 895 1190 1790 2045
19/32
3 720 17.0 960 10.0 1440 14.0 1640 24.0 1010 1345 2015 2295

AMERICAN WOOD COUNCIL


a. Nominal unit shear values shall be adjusted in accordance with 4.2.3 to deter-
mine ASD allowable unit shear capacity and LRFD factored unit resistance. For
general construction requirements see 4.2.6. For specific requirements, see 4.2.7.1
for wood structural panel diaphragms.
LATERAL FORCE-RESISTING SYSTEMS

b. For framing grades other than Douglas-Fir-Larch or Southern Pine, reduced nomi-
nal unit shear capacities shall be determined by multiplying the tabulated nominal
unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)],
where G = Specific Gravity of the framing lumber from the NDS. The Specific
Gravity Adjustment Factor shall not be greater than 1.
c. Apparent shear stiffness values, G_a, are based on nail slip and panel stiffness
values for diaphragms constructed with OSB panels. When plywood panels are
used, diaphragm deflections should be calculated in accordance with the ASD
Wood Structural Panels Supplement.
Table 4.2B Nominal Unit Shear Values for Wood-Frame Diaphragms
Table 4.2 (continued) Nominal Unit Shear Values
Table for Wood-Frame
4.2 (continued) Diaphragms
Nominal Unit Shear Values for Wood-Frame Diaphragms

Seismic C4 Draft.pmd
a,b a,b
Unblocked Wood Structural Panel Diaphragms Unblocked Wood Structural Panel Diaphragms
A B
A B
SEISMIC WIND
Minimum Minimum SEISMIC WIND
Minimum Minimum
Edge Nail Spacing : 6 inches Minimum Edge Nail Spacing: 6 inches
Fastener Nominal Minimum Edge Nail Spacing : 6 inches Edge Nail Spacing: 6 i
Common Nominal Fastener Nominal
Sheathing Grade Penetration in Panel Case 1
Common Cases 2,3,4,5,6 Nominal Case 1 Cases 2,3,4,5,6
Nail Size Sheathing
Framing Grade Penetration in Panel Case 1 Cases 2,3,4,5,6 Case 1 Cases
Framing Thickness Nail Size Framing
Width v_s G_a v_s
Framing G_a
Thickness v_w v_w
(inches) (inches) Width v_s G_a G_a v_w
(plf) (plf) (kips/in) v_s (plf) (plf)

17
(kips/in) (inches) (inches)
2 330 6.5 250 4.5 (plf) (kips/in) (plf) 460 (kips/in) 350 (plf)
6d 1 1/4 5/16
3 370 7.0 280 4.5 520 390
2 480 8.5 360 6.0 670 505
Structural Ic 8d 1 3/8 3/8
3 530 7.5 400 5.0 740 560
2 570 14.0 430 9.5 800 600
10d 1 1/2 15/32
3 640 12.0 480 8.0 895 670
2 300 9.0 220 6.0 420 310
5/16
3 340 7.0 250 5.0 475 350
6d 1 1/4
2 330 7.5 250 5.0 460 350
3/8
3 370 6.0 280 4.0 520 390
2 430 9.0 320 6.0 600 450
3/8
3 480 7.5 360 5.0 670 505
Sheathing and Single- 2 460 8.5 340 5.5 645 475
8d 1 3/8 7/16
Floorc 3 510 7.0 380 4.5 715 530
2 480 7.5 360 5.0 670 505
15/32
3 530 6.5 400 4.0 740 560
2 510 15.0 380 10.0 715 530
15/32
3 580 12.0 430 8.0 810 600
10d 1 1/2
2 570 13.0 430 8.5 800 600
19/32
3 640 10.0 480 7.0 895 670

a. Nominal unit shear values shall be adjusted in accordance with 4.2.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.2.6. For
specific requirements, see 4.2.7.1 for wood structural panel diaphragms.
b. For framing grades other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity
Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS. The Specific Gravity Adjustment Factor shall not be greater than 1.
c. Apparent shear stiffness values, G_a, are based on nail slip and panel stiffness values for diaphragms constructed with OSB panels. When plywood panels are used, diaphragm deflections should be calculated
in accordance with the ASD Wood Structural Panels Supplement.

AMERICAN FOREST & PAPER ASSOCIATION

7/26/2002, 10:43 AM
ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC
17

LATERAL FORCE-RESISTING SYSTEMS


4
18

Table 4.2C Nominal Unit Shear Values for Wood-Frame Diaphragms

Seismic C4 Draft.pmd
Lumber Diaphragmsa
A B
Sheathing Type, Size and Number of Nails per Board SEISMIC WIND
Sheathing Material Nominal Nailing at Intermediate and End Bearing Supports Nailing at Boundary Members v_s G_a v_w
Dimensions (Nails/board/support) (Nails/board/end) (plf) (kips/in) (plf)
1x6 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
Horizontal Lumber 1x8 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)
100 1.5 140

18
Sheathing 2x6 2-16d common nails (3-16d box nails) 3-16d common nails (5-16d box nails)
2x8 3-16d common nails (4-16d box nails) 4-16d common nails (6-16d box nails)
1x6 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
Diagonal Lumber 1x8 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)
600 6.0 840
Sheathing 2x6 2-16d common nails (3-16d box nails) 3-16d common nails (5-16d box nails)
2x8 3-16d common nails (4-16d box nails) 4-16d common nails (6-16d box nails)
1x6 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
Double Diagonal 1x8 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)
1200 9.5 1680
Lumber Sheathing 2x6 2-16d common nails (3-16d box nails) 3-16d common nails (5-16d box nails)
2x8 3-16d common nails (4-16d box nails) 4-16d common nails (6-16d box nails)

a. Nominal unit shear values shall be adjusted in accordance with 4.2.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction require-
ments see 4.2.6. For specific requirements, see 4.2.7.2 for diaphragms diagonally sheathed with a single layer of lumber, see 4.2.7.3 for diaphragms diagonally sheathed with a double layer
of lumber, and see 4.2.7.4 for diaphragms horizontally sheathed with a single layer of lumber.

AMERICAN WOOD COUNCIL


LATERAL FORCE-RESISTING SYSTEMS

6/11/02, 6:35 PM
ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 19

4.3 Wood Shear Walls


4.3.1 Application Requirements 4.3.2.1 Deflection of Perforated Shear Walls: The de-
flection of a perforated shear wall shall be calculated in
Wood shear walls are permitted to resist horizontal accordance with Section 4.3.2, where ν is equal to νmax in
forces provided the deflection of the shear wall, as deter- Equation 4.3-1 and b is taken as the sum of the perforated
mined by calculations, tests, or analogies drawn therefrom, shear wall segments ∑Li.
does not exceed the permissible deflection.
4.3.3 Shear Capacities
4.3.2 Deflection
The ASD allowable unit shear capacity shall be de- 4
Permissible deflection shall be that deflection up to termined by dividing the nominal unit shear capacity by a
which the shear wall and any attached distributing or re- safety factor of 2.0. No further increases shall be permit-

LATERAL FORCE-RESISTING SYSTEMS


sisting element will maintain its structural integrity under ted. The LRFD factored unit resistance shall be determined
design load conditions and continue to support design loads by multiplying the nominal unit shear capacity by a resis-
without danger to occupants of the structure. tance factor, φD, of 0.65.
Calculations of shear wall deflection shall account for 4.3.3.1 Tabulated Nominal Unit Shear Capacities:
bending and shear deflections, fastener deformation, an- Tabulated nominal unit shear capacities for seismic design
chorage slip, and other contributing sources of deflection. are provided in Column A of Tables 4.3A, B, and C and for
The shear wall deflection, δsw, is permitted to be cal- wind design in Column B of Tables 4.3A, B, and C.
culated by use of the following equation: 4.3.3.2 Summing Shear Capacities: For shear walls
sheathed with the same construction and materials on op-
8νh 3 νh h∆a posite sides of the same wall, the combined nominal unit
δ sw = + +
EAb 1000 G a b
(4.3-1) shear capacity, νsc or νwc, shall be permitted to be taken as
twice the nominal unit shear capacity for an equivalent
where: shear wall sheathed on one side.
For seismic design of shear walls sheathed with the
b = Shear wall length, ft.
same construction and materials on opposite sides of a
∆a = Total vertical elongation of wall anchorage shear wall, the shear wall deflection shall be calculated
system (including fastener slip, device using the combined apparent shear wall shear stiffness,
elongation, rod elongation, etc.), at the induced Gac and the combined nominal unit shear capacity, νsc,
shall be calculated using the following equations:
unit shear in the shear wall, in.
E = Modulus of elasticity of end posts, psi
G ac = G a 1 + G a 2 (4.3-2)
A = Area of end post cross-section, in.2

Ga = Apparent shear wall shear stiffness from nail


Vsc = K minGac (4.3-3)
slip and panel shear deformation, (from Column
A, Table 4.3), kips/in. where:
h = Shear wall height, ft. Gac = Combined apparent shear wall shear stiffness

ν = Induced unit shear, lbs./ft. of two-sided shear wall, kips/in.

δsw = Maximum shear wall deflection determined by Ga1 = Apparent shear wall shear stiffness for side 1,

elastic analysis, in. kips/in. (from Column A, Table 4.3)


Ga2 = Apparent shear wall shear stiffness for side 2,
Alternatively, for wood structural panel shear walls, kips/in. (from Column A, Table 4.3)
deflection is permitted to be calculated using a rational
Kmin = Minimum ratio of νs1/Ga1 or νs2/Ga2
analysis where apparent shear stiffness accounts for panel
shear deformation and non-linear nail slip in the sheath- νs1 = Nominal unit shear capacity for side 1, lbs./ft.
ing to framing connection. (from Column A, Table 4.3)

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C4 Draft.pmd 19 6/11/02, 6:35 PM


20 LATERAL FORCE-RESISTING SYSTEMS

νs2 = Nominal unit shear capacity for side 2, lbs./ft. 4.3.3.3 Summing Shear Wall Lines: The nominal
shear capacity for shear walls in a line utilizing shear walls
(from Column A, Table 4.3)
sheathed with the same construction and materials, shall
νsc = Combined nominal unit shear capacity of two- be permitted to be combined.
sided shear wall for seismic design, lbs./ft. 4.3.3.4 Shear Capacity of Perforated Shear Walls: The
nominal shear capacity of a perforated shear wall shall be
Nominal unit shear capacities for shear walls sheathed taken as the nominal unit shear capacity multiplied by the
with dissimilar materials on the same side of the wall are sum of the shear wall segment lengths, ∑Li, and the ap-
not cumulative. For shear walls sheathed with dissimilar propriate shear capacity adjustment factor, Co, from Table
materials on opposite sides, the combined nominal unit 4.3.3.4.
shear capacity, νsc or νwc, shall be either two times the
smaller nominal unit shear capacity or the larger nominal
unit shear capacity, whichever is greater.

Exception: For wind design, the combined nomi-


nal unit shear capacity νwc, of shear walls sheathed
with a combination of wood structural panels and
gypsum wall-board on opposite sides shall equal
the sum of the sheathing capacities of each side
separately.

Table 4.3.3.4 Shear Capacity Adjustment Factor, Co

o
MAXIMUM OPENING HEIGHT 1
WALL HEIGHT, h
h/3 h/2 2h/3 5h/6 h
8' Wall 2'-8" 4'-0" 5'-4" 6'-8" 8'-0"
10' Wall 3'-4" 5'-0" 6'-8" 8'-4" 10'-0"
Percent Full-Height Sheathing 2 Effective Shear Capacity Ratio
10% 1.00 0.69 0.53 0.43 0.36
20% 1.00 0.71 0.56 0.45 0.38
30% 1.00 0.74 0.59 0.49 0.42
40% 1.00 0.77 0.63 0.53 0.45
50% 1.00 0.80 0.67 0.57 0.50
60% 1.00 0.83 0.71 0.63 0.56
70% 1.00 0.87 0.77 0.69 0.63
80% 1.00 0.91 0.83 0.77 0.71
90% 1.00 0.95 0.91 0.87 0.83
100% 1.00 1.00 1.00 1.00 1.00
1
The maximum opening height shall be taken as the maximum opening clear height in a perforated shear wall. Where areas above and below
an opening remain unsheathed, the height of the opening shall be defined as the height of the wall.
2
The sum of the lengths of the perforated shear wall segments divided by the total length of the perforated shear wall.

AMERICAN WOOD COUNCIL

Seismic C4 Draft.pmd 20 6/11/02, 6:35 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 21

4.3.4 Shear Wall Aspect Ratios 4.3.5.2 Perforated Shear Walls: Where wood struc-
tural panel shear walls with openings are not designed for
Size and shape of shear walls shall be limited to the force transfer around the opening, they shall be designed
aspect ratios in Table 4.3.4. as perforated shear walls. The following limitations shall
apply:
Table 4.3.4 Maximum Shear Wall a. A perforated shear wall segment shall be lo-
Aspect Ratios cated at each end of a perforated shear wall.
Openings shall be permitted to occur beyond
Shear Wall Maximum the ends of the perforated shear wall, how-
Sheathing Type h/bs Ratio ever the length of such openings shall not be
included in the length of the perforated shear
Wood structural panels, all edges nailed
Particleboard, all edges nailed
3½:11
2:1 wall. 4
Diagonal Sheathing, conventional 2:1 b. The nominal unit shear capacity shall not ex-
Gypsum wallboard2 2:1 ceed 2,000 plf.

LATERAL FORCE-RESISTING SYSTEMS


Portland Cement Plaster2 2:1 c. Where out of plane offsets occur, portions of
Fiberboard 1½:1 the wall on each side of the offset shall be
1
For design to resist seismic forces, the shear wall aspect ratio shall not considered as separate perforated shear walls.
exceed 2:1 unless the nominal unit shear capacity is multiplied by 2bs/h. In d. Collectors for shear transfer shall be provided
no case shall the aspect ratio exceed 3½:1.
2
Walls having aspect ratios exceeding 1½:1 shall be blocked. through the full length of the perforated shear
wall.
4.3.4.1 Aspect Ratio of Perforated Shear Wall Seg- e. A perforated shear wall shall have uniform
ments: The aspect ratio limitations of 4.3.4 shall apply to top of wall and bottom of wall elevations.
perforated shear wall segments within a perforated shear Perforated shear walls not having uniform
wall. For design to resist seismic forces, the nominal shear elevations shall be designed by other meth-
capacity of the perforated shear wall shall be multiplied ods.
by 2bs/h when the aspect ratio of any perforated shear f. Perforated shear wall height, h, shall not ex-
wall segment included in the sum of shear wall segment ceed 20 feet.
lengths, ∑Li, is greater than 2:1, but does not exceed 3½:1.
Portions of walls with aspect ratios in excess of 3½:1 shall 4.3.6 Construction Requirements
not be counted in the sum of shear wall segments.
4.3.6.1 Framing Requirements: All framing used for
4.3.5 Shear Walls With Openings shear wall construction shall be 2x nominal or larger mem-
bers. Shear wall boundary elements, such as end posts,
The provisions of this section shall apply to the de- shall be provided to transmit the design tension and com-
sign of shear walls with openings. Where framing and pression forces. Shear wall sheathing shall not be used to
connections around the openings are designed for force splice boundary elements. End posts (studs or columns)
transfer around the openings the provisions of 4.3.5.1 shall shall be framed to provide full end bearing.
apply. Where framing and connections around the open- a. Tension and Compression Chords: Tension
ing are not designed for force transfer around the openings force, T, and a compression force, C, result-
the provisions of 4.3.5.2 shall apply. ing from shear wall overturning forces at each
4.3.5.1 Force Transfer Around Openings: Where story level shall be calculated in accordance
shear walls with openings are designed for force transfer with the following:
around the openings, the aspect ratio limitations of 4.3.4
T = C = νh (4.3-4)
shall apply to the overall shear wall including openings
and to each wall pier at the sides of an opening. The height where:
of a wall pier shall be defined as the clear height of the C = Compression chord force, lbs.
pier at the side of an opening. The length of a wall pier
h = Shear wall height, ft.
shall be defined as the sheathed length of the pier. Design
for force transfer shall be based on a rational analysis. T = Tension chord force, lbs.

The length of a wall pier shall not be less than 2 feet. ν = Induced unit shear, lbs./ft.

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C4 Draft.pmd 21 6/11/02, 6:35 PM


22 LATERAL FORCE-RESISTING SYSTEMS

Each end of each perforated shear wall shall be de- connecting shear wall segments, shall be
signed for a tension force, T, and a compression force, C. calculated in accordance with the follow-
Each end of each perforated shear wall segment shall be ing:
designed for a compression force, C, in each segment.
V
For perforated shear walls, the values for T and C result- νmax =
Co ∑ Li (4.3-6)
ing from shear wall overturning forces at each story level
shall be calculated in accordance with the following:
Vh b. Uplift Anchorage at Shear Wall Ends: Where
T =C = the dead load stabilizing moment is not suffi-
Co ∑ Li (4.3-5)
cient to prevent uplift due to overturning
where: moments on the wall (from 4.3.6.1a), an an-
Co = Shear capacity adjustment factor from Table choring device shall be provided at the end
of each shear wall.
4.3.3.4
(1) Uplift Anchorage for Perforated Shear
V = Induced shear force in perforated shear wall, lbs.
Walls: In addition to the requirements of
∑Li = Sum of perforated shear wall segment lengths, 4.3.6.4.b, perforated shear wall bottom
ft. plates at full height sheathing shall be an-
chored for a uniform uplift force, t, equal
4.3.6.2 Sheathing: Shear walls shall be sheathed with to the unit shear force, ν, determined in
approved materials. Sheathing nails or other approved Section 4.3.6.4.a.(1) or calculated by ra-
sheathing connectors shall be driven flush with the sur- tional analysis.
face of the sheathing. Details on sheathing types and c. Anchor Bolts: Foundation anchor bolts shall
thicknesses for commonly used shear wall assemblies are have a steel plate washer under each nut not
provided in 4.3.7 and Tables 4.3A, B, and C. less than 2½" x 2½" x ¼". The plate washer
4.3.6.3 Fasteners: Sheathing shall be attached to fram- shall extend to within ½" of the edge of the
ing using approved fasteners. Details on type, size, and bottom plate on the sheathed side.
spacing of mechanical fasteners in commonly used shear d. Load Path: A load path to the foundation shall
wall assemblies are provided in 4.3.7 and Tables 4.3A, B, be provided for uplift, shear, and compres-
and C. sion forces. Elements resisting shear wall
a. Adhesives: Adhesive attachment of shear wall forces contributed by multiple stories shall
sheathing is not permitted as a substitute for be designed for the sum of forces contributed
mechanical fasteners. Approved adhesive at- by each story.
tachment systems shall be permitted in Seismic
Design Categories A and B where R = 1.5 and 4.3.7 Shear Wall Systems
Ω0 = 2.5 unless other values are approved. In
Seismic Design Categories C-F, adhesive at- 4.3.7.1 Wood Structural Panel Shear Walls: Shear
tachment of shear wall sheathing is not walls sheathed with wood structural panel sheathing shall
permitted. be permitted to be used to resist seismic and wind forces.
4.3.6.4 Shear Wall Anchorage and Load Path: De- The size and spacing of fasteners at shear wall bound-
sign of shear wall anchorage and load path shall conform aries, panel edges, and intermediate supports shall be as
to the requirements of this section, or shall be calculated provided in Table 4.3A. The shear wall shall be constructed
using principles of mechanics. as follows:
a. Anchorage for In-plane Shear: Connections a. Panels installed either horizontally or verti-
shall be provided to transfer the induced unit cally with panel joints occurring over
shear force, ν, into and out of each shear wall. common studs or blocking. Panels not less
(1) In-plane Shear Anchorage for Perforated than 4 ft. x 8 ft. except that a single panel
Shear Walls: The maximum induced unit with a minimum dimension of 1 foot is per-
shear force, νmax, transmitted into the top mitted if it is fully blocked and nailed.
of a perforated shear wall, out of the base b. Nails spaced not less than 3/8 inch from edges
of the perforated shear wall at full height and ends of panels, studs, blocking, and top
sheathing, and into collectors (drag struts) and bottom plates. Maximum nail spacing

AMERICAN WOOD COUNCIL

Seismic C4 Draft.pmd 22 6/11/02, 6:36 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 23

of 6 inches along intermediate framing mem- studs) with panel joints occurring over com-
bers for 3/8-inch and 7/16-inch panels mon studs or blocking.
installed on studs spaced 24 inches o.c. Maxi- b. Nails spaced not less than 3/8 inch from edges
mum nail spacing along intermediate framing and ends of panels, studs, blocking, and top
of 12 inches for other conditions. and bottom plates. Maximum nail spacing 6
c. 2x or wider framing at adjoining panel edges inches along intermediate framing members.
except that 3x or wider framing and staggered c. 2x or wider framing at adjoining panel edges.
nailing are required where: d. Maximum stud spacing of 16 inches.
(1) nails are spaced 2 inches o.c., or e. Minimum length of galvanized roofing nails
(2) 10d nails having penetration into framing is 1½" for ½ inch thick sheathing and 1¾"
of more than 1-1/2 inches are spaced 3 for 25/32 inch thick sheathing.
inches o.c., or less, or f. Fiberboard sheathing shall conform to either 4
(3) nominal unit shear capacity exceeds 700 AHA 194.1 or ASTM C208.
plf in seismic Design Category D, E, or F. 4.3.7.4 Gypsum Wallboard, Gypsum Veneer Base,

LATERAL FORCE-RESISTING SYSTEMS


d. Maximum stud spacing of 24 inches. Water-Resistant Backing Board, Gypsum Sheathing, Gyp-
e. Wood structural panels shall conform to the sum Lath and Plaster, or Portland Cement Plaster Shear
requirements for its type in DOC PS1 or PS2. Walls: Shear walls sheathed with gypsum wallboard, gyp-
4.3.7.2 Particleboard Shear Walls: Shear walls sum veneer base, water-resistant backing board, gypsum
sheathed with particleboard sheathing shall be permitted sheathing, gypsum lath and plaster, or portland cement
to be used to resist wind forces and seismic forces in Seis- plaster shall be permitted to be used to resist wind forces
mic Design Categories A, B, and C. The size and spacing and seismic forces in Seismic Design Categories A-D. End
of fasteners at shear wall boundaries, panel edges, and joints of adjacent courses of gypsum wallboard or sheath-
intermediate supports shall be as provided in Table 4.3A. ing shall not occur over the same stud. The size and spacing
The shear wall shall be constructed as follows: of fasteners at shear wall boundaries, panel edges, and
a. Panels installed either horizontally or verti- intermediate supports shall be as provided in Table 4.3B.
cally with panel joints occurring over Nails shall be spaced not less than 3/8 inch from edges
common studs or blocking. Panels not less and ends of panels, studs, blocking, and top and bottom
than 4 feet x 8 feet except that a single panel plates. Wood framing shall be 2x or wider.
with a minimum dimension of 1 foot is per- a. Gypsum Wallboard, Gypsum Veneer Base,
mitted if it is fully blocked and nailed. Water-Resistant Backing Board: Gypsum
b. Nails spaced not less than 3/8 inch from edges wallboard, gypsum veneer base, or water-
and ends of panels, studs, blocking, and top resistant backing board shall be applied
and bottom plates. Maximum nail spacing parallel or perpendicular to studs. Gypsum
of 6 inches along intermediate framing mem- wallboard shall conform to ASTM C36 and
bers for 3/8-inch panels installed on studs shall be installed in accordance with ASTM
spaced 24 inches o.c. Maximum nail spac- C 840. Gypsum veneer base shall conform
ing along intermediate framing of 12 inches to ASTM C 588 and shall be installed in ac-
for other conditions. cordance with ASTM C 844. Water-resistant
c. 2x or wider framing at adjoining panel edges. backing board shall conform to ASTM C630
d. Maximum stud spacing of 24 inches. and shall be installed in accordance with
e. Particleboard shall conform to ANSI A208.1. ASTM C 840.
4.3.7.3 Fiberboard Shear Walls: Shear walls sheathed b. Gypsum Sheathing: Four-foot-wide pieces of
with fiberboard sheathing shall be permitted to be used to gypsum sheathing shall be applied parallel or
resist wind forces and seismic forces in Seismic Design perpendicular to studs. Two-foot-wide pieces
Categories A, B, and C. The size and spacing of fasteners of gypsum sheathing shall be applied perpen-
at shear wall boundaries, panel edges, and intermediate dicular to the studs. Gypsum sheathing shall
supports shall be as provided in Table 4.3A. The shear conform to ASTM C79 and shall be installed
wall shall be constructed as follows: in accordance with ASTM C 1280.
a. 4 feet x 8 feet fiberboard sheathing shall be c. Gypsum Lath and Plaster: Gypsum lath shall
applied vertically (long dimension parallel to be applied perpendicular to the studs. Gyp-
sum lath shall conform to ASTM C37 and

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C4 Draft.pmd 23 6/11/02, 6:36 PM


24 LATERAL FORCE-RESISTING SYSTEMS

shall be installed in accordance with ASTM on the same face of the supporting members. Nailing of
C 841. Gypsum plaster shall conform to the diagonally sheathed lumber shear walls shall be in accor-
requirements of ASTM C 28. dance with Table 4.3C.
d. Expanded Metal or Woven Wire Lath and 4.3.7.7 Shear Walls Horizontally Sheathed with
Portland Cement: Expanded metal or woven Single-Layer of Lumber: Horizontally sheathed lumber
wire lath and portland cement shall conform shear walls are permitted to be used to resist wind forces
to ASTM C847, ASTM 1032, and ASTM C and seismic forces in Seismic Design Categories A, B,
150 and shall be installed in accordance with and C. Horizontally sheathed lumber shear walls shall be
ASTM C 926 and ASTM C 1063. Metal lath constructed of minimum 1-inch thick nominal sheathing
and lath attachments shall be of corrosion- boards applied perpendicular to the supports. End joints
resistant material. in adjacent boards shall be separated by at least one stud
4.3.7.5 Shear Walls Diagonally Sheathed with Single- space and there shall be at least two boards between joints
Layer of Lumber: Single diagonally sheathed lumber shear on the same support. Nailing of horizontally sheathed
walls are permitted to be used to resist wind forces and lumber shear walls shall be in accordance with Table 4.3C.
seismic forces in Seismic Design Catergories A, B, C, and 4.3.7.8 Shear Walls Sheathed with Vertical Board Sid-
D. Single diagonally sheathed lumber shear walls shall be ing: Vertical board siding shear walls are permitted to be
constructed of minimum 1-inch thick nominal sheathing used to resist wind forces and seismic forces in Seismic
boards laid at an angle of approximately 45° to the sup- Design Categories A, B, and C. Vertical board siding shear
ports. End joints in adjacent boards shall be separated by walls shall be constructed of minimum 1-inch thick nomi-
at least one stud space and there shall be at least two boards nal sheathing boards applied directly to studs and blocking.
between joints on the same support. Nailing of diagonally Nailing of vertical board siding shear walls shall be in
sheathed lumber shear walls shall be in accordance with accordance with Table 4.3C.
Table 4.3C.
4.3.7.6 Shear Walls Diagonally Sheathed with Double-
Layer of Lumber: Double diagonally sheathed lumber
shear walls are permitted to be used to resist wind forces
and seismic forces in Seismic Design Categories A, B, C,
and D. Double diagonally sheathed lumber shear walls
shall be constructed of two layers of 1-inch thick nominal
diagonal sheathing boards laid perpendicular to each other

AMERICAN WOOD COUNCIL

Seismic C4 Draft.pmd 24 6/11/02, 6:36 PM


Table 4.3A Nominal Unit Shear Values for Wood-Frame Shear Wallsa,c

Seismic C4 Draft.pmd
Wood-based Sheathing
A B
Minimum Minimum SEISMIC WIND
Nominal Fastener Panel Edge Fastener Spacing (inches) Panel Edge Fastener Spacing (inches)
Fastener
Sheathing Material Panel Penetration in 6 4 3 2 6 4 3 2
Type & Size

25
Thickness Framing v_s G_a v_s G_a v_s G_a v_s G_a v_w v_w v_w v_w
(inches) (inches) (plf) (kips/in) (plf) (kips/in) (plf) (kips/in) (plf) (kips/in) (plf) (plf) (plf) (plf)
Nail (common or
galvanized box)
5/16 1-1/4 6d 400 13.0 600 18.0 780 23.0 1020 35.0 560 840 1090 1430
Wood Structural
3/8b 460 19.0 720 24.0 920 30.0 1220 43.0 645 1010 1290 1710
Panels - Structural Id
7/16b 1-3/8 8d 510 16.0 790 21.0 1010 27.0 1340 40.0 715 1105 1415 1875
15/32 560 14.0 860 18.0 1100 24.0 1460 37.0 785 1205 1540 2045
15/32 1-1/2 10d 680 22.0 1020 29.0 1330 36.0 1740 50.0 950 1430 1860 2435
5/16 360 13.0 540 18.0 700 24.0 900 37.0 505 755 980 1260
1-1/4 6d
3/8 400 11.0 600 15.0 780 20.0 1020 32.0 560 840 1090 1430
3/8b 440 17.0 640 25.0 820 31.0 1060 45.0 615 895 1150 1485
Wood Structural
d 7/16b 1-3/8 8d 480 15.0 700 22.0 900 28.0 1170 42.0 670 980 1260 1640
Panels - Sheathing
15/32 520 13.0 760 19.0 980 25.0 1280 39.0 730 1065 1370 1790
15/32 620 22.0 920 30.0 1200 37.0 1540 52.0 870 1290 1680 2155
1-1/2 10d
19/32 680 19.0 1020 26.0 1330 33.0 1740 48.0 950 1430 1860 2435
Nail (galvanized casing)
Plywood Siding
5/16 1-1/4 6d 280 13.0 420 16.0 550 17.0 720 21.0 392 588 770 1008
3/8 1-1/2 8d 320 16.0 480 18.0 620 20.0 820 22.0 448 672 868 1148
Nail (common or
Particleboard galvanized box)
Sheathing - 3/8 6d 240 15.0 360 17.0 460 19.0 600 22.0 335 505 645 840
(M-S "Exterior Glue" 3/8 8d 260 18.0 380 20.0 480 21.0 630 23.0 365 530 670 880
and M-2 "Exterior 1/2 280 18.0 420 20.0 540 22.0 700 24.0 390 590 755 980

AMERICAN FOREST & PAPER ASSOCIATION


Glue") 1/2 10d 370 21.0 550 23.0 720 24.0 920 25.0 520 770 1010 1290
5/8 400 21.0 610 23.0 790 24.0 1040 26.0 560 855 1105 1455
Nail (common or
galvanized roofing)
8d common or 11 ga. galv.
Fiberboard Sheathing - 1/2 roofing nail (0.120" x 1 1/2" 340 4.0 460 5.0 520 5.5 475 645 730

7/26/2002, 11:46 AM
Structural long x 7/16" head)
8d common or 11 ga. galv.
25/32 roofing nail (0.120" x 1 3/4" 360 4.0 480 5.0 540 5.5 505 670 755
long x 7/16" head)

a. Nominal unit shear values shall be adjusted in accordance with 4.3.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For
specific requirements, see 4.3.7.1 for wood structural panel shear walls, 4.3.7.2 for particleboard shear walls, and 4.3.7.3 for fiberboard shear walls.
ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC

b. Shears are permitted to be increased to values shown for 15/32 inch sheathing with same nailing provided (a) studs are spaced a maximum of 16 inches o.c., or (b) if panels are applied with long dimension
across studs.
c. For framing grades other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity
Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS. The Specific Gravity Adjustment Factor shall not be greater than 1.
d. Apparent shear stiffness values, G_a, are based on nail slip and panel stiffness values for shear walls constructed with OSB panels. When plywood panels are used, shear wall deflections should be calculated
in accordance with the ASD Wood Structural Panels Supplement.
25

LATERAL FORCE-RESISTING SYSTEMS


4
26

Table 4.3B Nominal Unit Shear Values for Wood-Frame Shear Wallsa

Seismic C4 Draft.pmd
Gypsum and Cement Plaster
A B
Material Max. Fastener Max. Stud
SEISMIC WIND
b
Sheathing Material Fastener Type & Size v_s G_a v_w
Thickness Edge Spacing c Spacing
(plf) (kips/in) (plf)
7" 24" unblocked 150 4.0 150

26
5d cooler (0.086" x 1-5/8" long, 15/64" head) or wallboard nail (0.086" x 1-5/8" long, 9/32" 4" 24" unblocked 220 6.5 220
head) or 0.120" nail x 1-1/2" long, min 3/8" head 7" 16" unblocked 200 5.5 200
4" 16" unblocked 250 7.0 250
7" 16" blocked 250 6.5 250
No. 6 Type S or W drywall screws 1-1/4" long
1/2" 4" 16" blocked 300 9.0 300
8/12" 16" unblocked 120 3.0 120
4/16" 16" blocked 320 8.5 320
No. 6 Type S or W drywall screws 1-1/4" long 4/12" 24" blocked 310 9.5 310
Gypsum wallboard,
8/12" 16" blocked 140 4.0 140
gypsum veneer base, or
6/12" 16" blocked 180 5.0 180
water-resistant gypsum
6d cooler (0.092" x 1-7/8" long, 1/4" head) or wallboard nail (0.0915" x 1-7/8" long, 19/64" 7" 24" unblocked 230 6.0 230
backing board
head) or 0.120" nail x 1-3/4" long, min 3/8" head 4" 24" unblocked 290 8.0 290
7" 16" blocked 290 7.5 290
5/8" No. 6 Type S or W drywall screws 1-1/4" long
4" 16" blocked 350 10.0 350
8/12" 16" unblocked 140 4.0 140
No. 6 Type S or W drywall screws 1-1/4" long
8/12" 16" blocked 180 4.0 180
Base ply--6d cooler (0.092" x 1-7/8" long, 1/4" head) or wallboard nail (0.0915" x 1-7/8"
5/8" long, 19/64" head) or 0.120"nail x 1-3/4" long, min 3/8" head
Base: 9"
16" blocked 500 17.0 500
Face ply--8d cooler (0.113" x 2-38" long, 0.281" head) or wallboard nail (0.113" x 2-3/8"
(Two-Ply) long, 3/8" head) or 0.120" nail x 2-3/8" long, min 3/8" head
Face: 7"

1/2" x 2' x 8' 4" 16" unblocked 150 5.0 150


0.120" nail x 1 3/4" long, 7/16" head, diamond-point, galvanized
4" 24" blocked 350 10.0 350
Gypsum sheathing 1/2" x 4'
7" 16" unblocked 200 5.0 200
6d galvanized cooler (0.092" x 1-7/8" long, 1/4" head) or wallboard nail (0.0915" x 1-7/8" 4/7"

AMERICAN WOOD COUNCIL


5/8" x 4' 16" blocked 400 13.0 400
long, 19/64" head) or 0.120" nail x 1-3/4" long, min 3/8" head
Gypsum lath, plain or 3/8" lath and 0.092"x 1-1/8" long, 19/64" head, gypsum wallboard blued nail or 0.120" nail x1 1/4" long,
5" 16" unblocked 200 6.5 200
perforated 1/2" plaster min 3/8" head
Expanded metal or woven
wire lath and portland 7/8" 0.120" nail x 1½” long, 7/16" head 6" 16" unblocked 360 12.0 360
LATERAL FORCE-RESISTING SYSTEMS

cement plaster

a. Nominal unit shear values shall be adjusted in accordance with 4.3.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For

6/11/02, 6:36 PM
specific requirements, see 4.3.7.4.
b. Type S or W drywall screws shall conform to requirements of ASTM C 1002.
c. Where two numbers are given for maximum fastener edge spacing, the first number denotes fastener spacing at the edges and the second number denotes fastener spacing in the field.
Table 4.3C Nominal Unit Shear Values for Wood-Frame Shear Wallsa

Seismic C4 Draft.pmd
Lumber Shear Walls
A B
Sheathing Type, Size and Number of Nails per Board SEISMIC WIND
Sheathing Material Nominal Nailing at Intermediate Studs Nailing at Shear Wall Boundary Members v_s G_a v_w
Dimensions (nails/board/support) (nails/board/end) (plf) (kips/in) (plf)

27
Horizontal Lumber 1x6 & smaller 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
100 1.5 140
Sheathing 1x8 & larger 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)
Diagonal Lumber 1x6 & smaller 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
600 6.0 840
Sheathing 1x8 & larger 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)
Double Diagonal Lumber 1x6 & smaller 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
1200 10.0 1680
Sheathing 1x8 & larger 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)
1x6 & smaller 2-8d common nails (3-8d box nails) 3-8d common nails (5-8d box nails)
Vertical Lumber Siding 90 1.0 125
1x8 & larger 3-8d common nails (4-8d box nails) 4-8d common nails (6-8d box nails)

a. Nominal unit shear values shall be adjusted in accordance with 4.3.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For
specific requirements, see 4.3.7.5 - 4.3.7.8.

AMERICAN FOREST & PAPER ASSOCIATION

6/11/02, 6:36 PM
ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC
27

LATERAL FORCE-RESISTING SYSTEMS


4
28 LATERAL FORCE-RESISTING SYSTEMS

AMERICAN WOOD COUNCIL

Seismic C4 Draft.pmd 28 6/11/02, 6:36 PM


ASD/LRFD SUPPLEMENT – SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC 29

REFERENCES

AMERICAN FOREST & PAPER ASSOCIATION

Seismic C5 Draft.pmd 29 4/22/02, 8:25 AM


30 REFERENCES

References
1. AHA A194.1-85, Cellulosic Fiber Board, American 13. ASTM C840-01, Standard Specification for Appli-
Hardboard Association, Palatine, IL, 1985. cation and Finishing of Gypsum Board, ASTM, West
Conshocken, PA, 2001.
2. ANSI/AHA A135.4-95, Basic Hardboard, American
Hardboard Association, Palatine, IL, 1995. 14. ASTM C841-99, Standard Specification for Instal-
lation of Interior Lathing and Furring, ASTM, West
3. ANSI/AHA A135.5-95, Prefinished Hardboard Pan-
Conshocken, PA, 1999.
eling, American Hardboard Association, Palatine, IL,
1995. 15. ASTM C844-99, Standard Specification for Appli-
cation of Gypsum Base to Receive Gypsum Veneer
4. ANSI A208.1-93, Particleboard, ANSI, New York,
Plaster, ASTM, West Conshocken, PA, 1999.
NY, 1993
16. ASTM C847-95(2000), Standard Specification for
5. ASTM C28/C28M-01, Standard Specification for
Metal Lath, ASTM, West Conshocken, PA, 2000.
Gypsum Plasters, ASTM, West Conshocken, PA,
2001. 17. ASTM C926-98a, Standard Specification for Appli-
cation of Portland Cement Based Plaster, ASTM,
6. ASTM C36/C36M-01, Standard Specification for
West Conshocken, PA, 1998.
Gypsum Wallboard, ASTM, West Conshocken, PA,
2001. 18. ASTM C1032-96, Standard Specification for Woven
Wire Plaster Base, ASTM, West Conshocken, PA,
7. ASTM C37/C37M-01, Standard Specification for
1996.
Gypsum Lath, ASTM, West Conshocken, PA, 2001.
19. ASTM C1063-99, Standard Specification for Instal-
8. ASTM C79/C79M-01, Standard Specification for
lation of Lathing and Furring to Receive Interior and
Treated Core and Non-treated Core Gypsum Sheath-
Exterior Portland Cement-Based Plaster, ASTM,
ing Board, ASTM, West Conshocken, PA, 2001.
West Conshocken, PA, 1999.
9. ASTM C150-00, Standard Specification for Portland
20. ASTM C1280-99, Standard Specification for Appli-
Cement, ASTM, West Conshocken, PA, 2000.
cation of Gypsum Sheathing, ASTM, West
10. ASTM C208-95(2001), Standard Specification for Conshocken, PA, 1999.
Cellulosic Fiber Insulation Board, ASTM, West
21. PS1-95 Construction and Industrial Plywood, United
Conshocken, PA, 2001.
States Department of Commerce, National Institute
11. ASTM C588/C588M-01, Standard Specification for of Standards and Technology, Gaithersburg, MD,
Gypsum Base for Veneer Plasters, ASTM, West 1995.
Conshocken, PA, 2001.
22. PS2-92 Performance Standard for Wood-Based
12. ASTM C630/C630M-01, Standard Specification for Structural Use Panels, United States Department of
Water-Resistant Gypsum Backing Board, ASTM, Commerce, National Institute of Standards and Tech-
West Conshocken, PA, 2001. nology, Gaithersburg, MD, 1992.

AMERICAN WOOD COUNCIL

Seismic C5 Draft.pmd 30 4/22/02, 8:25 AM

Anda mungkin juga menyukai