3
bends
8 in., 8-ft long, 2 bends
Steam pressure = 645 psia. Total head =18 ft. Drum internal loss 0.3 psi.
Evaporator tube ID =1.738 in length=11 ft.
rator circuits, this graphical method is sometimes
used, although it is tedious. If the downcomer or
external riser piping consists of several parallel or
parallel-series paths, the electrical analogy is used to
determine flow and pres sure drop in each circuit. A
computer program best handles this problem.
EXAMPLE CALCULATION
Fig. 1 is a waste-heat boiler operating under the
following conditions:
Gas flow = 200,000 lb/hr
Gas inlet temperature = 1,650°F (vol% C02 =7,
H2O = 18, N2 = 69, 02 = 6)
Steam pressure = 500 psia
Feed water temperature = 230°F
The total steam generated is 63,5001b/hr. The
first four rows are bare, followed by six finned tubes
and then 10 more with higher fin density. Details of
downcomers, riser pipes and other pertinent
information are in Table 1.
Determine the system's circulation ratio and the
flow in each pipe circuit. Note that the boiler design
calculations must be done before circulation studies
can be taken up. Also, one must have a good feel for
the downcomer and riser pipe sizes and their layout.
Often piping layout is changed at the last moment to
accommodate other equipment in the plant without
reevaluating circulation. A computer program was
developed to perform this analysis. The evaporator
4HYDROCARBONPROCESSING/JANUARY1998
For water tube boilers, heat flux, q = Uo x ( tg - ts) x
At/Ai ,Where Uo = overall outside heat -transfer
coefficient, Btu/ft2-hr-°F
tg, i s are gas and steam temperatures, °F
At, Ai are the tube outside and inside surface areas,
ft2/ft. This ratio is for bare tubes, while for finned tubes it
could be high, say 5 to 12. Hence, one must be careful
while analyzing finned tube bundles, as the heat flux can
be very high inside the tubes.
In fire tube boilers, q = Uo x ( tg - ts)
Based on preliminary analyses, the CR in each circuit
and overall basis seems to be reasonable. The maximum
heat flux at the inlet to each section is in Table 1. Correlations
are available in the literature for allowable heat flux
as a function of pressure, quality and tube size, etc. These
are mostly based on experimental data conducted in
laboratories and are often used for guidance only. The
5 of 8 11/4/2018, 10:58 AM
boiler circulation calculation | THERMAL POWER PLANT A-Z https://powerplanta2z.blogspot.com/2015/09/boiler-circulation-calculatio...
6 of 8 11/4/2018, 10:58 AM
boiler circulation calculation | THERMAL POWER PLANT A-Z https://powerplanta2z.blogspot.com/2015/09/boiler-circulation-calculatio...
7 of 8 11/4/2018, 10:58 AM
boiler circulation calculation | THERMAL POWER PLANT A-Z https://powerplanta2z.blogspot.com/2015/09/boiler-circulation-calculatio...
namely the tubes that connect the bot tom header to the
top header and the header itself, which has an L-shape.
Flow calculations were done and orifices were used to
ensure proper flow distribution in all the heated circuits.