FLOOR LINE
0.4
EXISTING TIE BEAM
ROUGHEN SURFACE, APPLY EPOXY BONDING
PRIOR TO POURING OF NEW CONCRETE NEW STEEL COLUMN
15" x 15" x 21" BASE PLATE W10 x 49
0.6
4-43" DIA. ANCHOR BOLT 15" x 15" x 21" BASE PLATE ADDITIONAL
NEW PEDESTAL
4-43" DIA. ANCHOR BOLT COLUMN ELEVATION
W10 x 49
SCALE: NTS
LATERAL TIES
0.55
2ND APPLICATION 1 LAYER SCH-11UP
1 LAYER SEH-25A GLASS FIBER,
FULL WRAP W/ VERTICAL ORIENTATION
EXISTING TIE BEAM- WRAP AROUND ( FULL LENGTH )
NEW PEDESTAL CONN. DET.
SCALE: NTS
1ST APPLICATION 2 LAYERS SEH-25A
ADDITIONAL STEEL FULL WRAP W/ HORIZONTAL ORIENTATION
COLUMN DETAIL
SCALE: NTS
FINNISH
FLOOR LINE FINNISH
FLOOR LINE
15" x 15" x 21" BASE PLATE
NEW STEEL COLUMN
4-43" DIA. ANCHOR BOLT NATURAL GROUND LINE
LOCATION:
5
E-mail: ecstructuralcomposites@gmail.com
Website: www.ecstructural.com PTR NO.: PLACE/DATE ISSUED:
DRAWN BY: CJB CHECKED BY: HBJ DATE: OCT,2018
CONTRACTOR:
EC STRUCTURAL COMPOSITES, INC.
4F EC Center Bldg., Mindanao Avenue Ext., Brgy. Pasong Putik, Quezon City, 1118
1 2 3 4 4' '5 5 6 7 8
S
B2 B2 B2 B2
3.70M
B2
B2
B2
B2
B2
B2
F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1
R
B2 B2 B2 B2 B2 B2
4.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-2 F-2 F-2 F-2
F-1 F-1 F-1 F-1
Q
B2 B2 B2 B2 B2 B2
4.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-2 F-2 F-2 F-2
F-1 F-1 F-1 F-1
P
B2 B2 B2 B2 B2 B2
4.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-2 F-2 F-2 F-2
PTR NO.:
PRC. NO.:
O
B2 B2 B2 B2 B2 B2
4.00M
B2
B2
B2
B2
B2
B2
B2
B2
ENGR. HEHERSON B. JUAN
N
B2 B2 B2 B2 B2 B2
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
PLACE/DATE ISSUED:
TIN NO:
M
B2 B2 B2 B2 B2 B2
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-3 F-3
F-2 F-2 F-2 F-2
F-1 F-1
L
B2 B2 B2 B1 B1 B2 B2 B2
5.21M
B1
CLIENT:
B2
B2
B2
B2
B2
B2
B2
B2
K
2.79M
F-3 F-3
B2
B2
F-2 F-2 F-2 F-2
F-1 F-1
J
B2 B2 B2 B1 B1 B1 B2 B2 B2
4.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-2 F-2 F-2 F-2
F-1 F-1
I B1 B1 B1
B2 B2 B2 B2 B2 B2
3.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-1 F-1
H
B2 B2 B2 B1 B1 B1 B2 B2 B2
5.00M
F-4 F-4
B2
B2
B2
B2
B2
B2
B2
B2
F-2 F-2 F-2 F-2
F-1 F-1
G B1 B1 B1
B2 B2 B2 B2 B2 B2
4.00M
B2
B2
B2
B2
B2
B2
B2
B2
LOCATION:
PROJECT TITLE:
F
B2 B2 B2 B1 B1 B1 B2 B2 B2
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
F-2 F-2 F-2 F-2
F-1 F-1
E
B2 B2 B2 B1 B1 B1 B2 B2 B2
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
D
B2 B2 B2 B1 B1 B1 B2 B2 B2
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
C
B1 B1 B1
DRAWN BY: CJB
B2 B2 B2 B2 B2 B2
SHEET CONTENT:
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
B
B2 B2 B2 B1 B1 B1 B2 B2 B2
5.00M
B2
B2
B2
B2
B2
B2
B2
B2
CHECKED BY: HBJ
F-3 F-3
F-2 F-2 F-2 F-2
F-1 F-1
A
B2 B2 B2 B1 B1 B1 B2 B2 B2
1
No:
REVISION:
REVISION
REFERENCE No.
DATE:
LEGEND:
DATE: OCT,2018
SHEET NO.:
= EXTENTION FOOTING
5
1
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
8
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
7
2.50M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
6
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
NTS
TYPICAL KEY PLAN FROM
GROUND TO 5TH FLOOR
5
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
5.00M
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
'5
10.00M
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
4'
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
5.00M
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
SCALE:
4
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
3
2.50M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
BEAMS TO BE RETROFITTED
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
ADDITIONAL COLUMN
1
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
3.70M 4.00M 4.00M 4.00M 4.00M 5.00M 5.00M 5.21M 2.79M 4.00M 3.00M 5.00M 4.00M 5.00M 5.00M 5.00M 5.00M 5.00M
=TYPE 1
=TYPE 2
M
Q
C
R
D
S
H
K
F
P
A
E
B
L
LEGEND:
CONTRACTOR: ENGINEER: CLIENT: PROJECT TITLE: SHEET CONTENT: REVISION: SHEET NO.:
No: REFERENCE No. DATE
EC STRUCTURAL COMPOSITES, INC.
ENGR. HEHERSON B. JUAN
1 REVISION 12-03-18 2
4F EC Center Bldg., Mindanao Avenue Ext., Brgy. Pasong Putik, Quezon City, 1118
Trunkline: 962-55-55 Fax: loc. 801 PRC. NO.: TIN NO:
LOCATION:
5
E-mail: ecstructuralcomposites@gmail.com
Website: www.ecstructural.com PTR NO.: PLACE/DATE ISSUED:
DRAWN BY: CJB CHECKED BY: HBJ DATE: OCT,2018
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
8
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
7
2.50M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
6
NTS
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
5
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
5.02M
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
'5
10.00M
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
4'
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
4.98M
SCALE:
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
4
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
3
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
2
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
BEAMS TO BE RETROFITTED
6.00M
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
1
B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2
3.70M 4.00M 4.00M 4.00M 4.00M 5.00M 5.00M 5.21M 2.79M 4.00M 3.00M 5.00M 4.00M 5.00M 5.00M 5.00M 5.00M 5.00M
M
O
C
R
LEGEND:
S
F
P
A
Q
B
L
I
CONTRACTOR: ENGINEER: CLIENT: PROJECT TITLE: SHEET CONTENT: REVISION: SHEET NO.:
No: REFERENCE No. DATE
EC STRUCTURAL COMPOSITES, INC.
ENGR. HEHERSON B. JUAN
1 REVISION 12-03-18 3
4F EC Center Bldg., Mindanao Avenue Ext., Brgy. Pasong Putik, Quezon City, 1118
Trunkline: 962-55-55 Fax: loc. 801 PRC. NO.: TIN NO:
LOCATION:
5
E-mail: ecstructuralcomposites@gmail.com
Website: www.ecstructural.com PTR NO.: PLACE/DATE ISSUED:
DRAWN BY: CJB CHECKED BY: HBJ DATE: OCT,2018
SEE FOOTING DETAILS
GROUND FLOOR
SECOND FLOOR
FOURTH FLOOR
NGL
THIRD FLOOR
FIFTH FLOOR
SCALE:
LINE
LINE
LINE
LINE
LINE
CONTRACTOR: ENGINEER: CLIENT: PROJECT TITLE: SHEET CONTENT: REVISION: SHEET NO.:
No: REFERENCE No. DATE
EC STRUCTURAL COMPOSITES, INC.
ENGR. HEHERSON B. JUAN
1 REVISION 12-03-18 4
4F EC Center Bldg., Mindanao Avenue Ext., Brgy. Pasong Putik, Quezon City, 1118
Trunkline: 962-55-55 Fax: loc. 801 PRC. NO.: TIN NO:
LOCATION:
5
E-mail: ecstructuralcomposites@gmail.com
Website: www.ecstructural.com PTR NO.: PLACE/DATE ISSUED:
DRAWN BY: CJB CHECKED BY: HBJ DATE: OCT,2018