Anda di halaman 1dari 1

Decoder Combinations 2 x Exploras 3 x Exploras 3 x Exploras 3 x Exploras + 4U,4S Explora + 4U,4S Explora + 4T legacy Explora + 2T legacy Explora + 2T legacy

Ports used A B A B C A B C A B C D A B C D A (4P,4U) B (Expl) A (2P,2U) B (Expl) A (2P,2U) B (Expl)


Userbands Frequencies
0 1210 T1 T1 T1 T1 T1 T1 T1 T1
1 1420 T2 T2 T2 T2 T2 T2 T2 T2
2 1680 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T1
3 2040 T1 T1 T1 T1 T1 T4
4 1006 T2 T2 T2 T2 T1 T1 T1 T2
5 1057 T3 T1 T1 T1 T2 T2 T2
6 1108 T2 T2 T2 T3 T3
7 1159 T3 T1 T3
Decoder Combinations 1 x 2P,2U + 2 x Exploras 1 x 2P,2U + 2 x Exploras 1 x 2P,2U + 2 x Exploras + 1 x 4U,4S 2 x Explora + 4U,4S Explora + 2T legacy Explora + 2T legacy
Ports used A (2P,2U) B C A (2P,2U) B C A B C D A B C D A (2P,2U) B (Expl) A (2P,2U) B (Expl)
Userbands Frequencies
0 1210 T1 T1 T1 T1 T1 T1
1 1420 T2 T2 T2 T2 T2 T2
2 1680 T3 T3 T1 T3 T3 T3 T1
3 2040 T1 T2 T1 T1 T2
4 1006 T2 T3 T2 T2 T1 T3
5 1057 T1 T1 T1 T3 T2
6 1108 T2 T2 T2 T1 T3
7 1159 T3 T1 T2
Notes:
1. Best NOT to share any user bands between decoders.
2. Not always possible given the sw limitations, so sharing of tuner 3 settings on combinations of Exploras is the Only way.
3. DO NOT share userbands between (Explora, 4U, 4S) and Legacy decoders.
4. Sharing of a user band between Exploras on tuner 3 works. This is required when using the Explora 5-2 switch.
5. Some combinations are theoretically possible but have not been tested any any users (yet)
6. NB Only two decoders under one subscription are allowed at this point in time.
7. Port A seems to work best with Legacy Decoders (unconfirmed as to why this should be)
8. Some reports suggest that the gap between user band frequencies on a multi tuner decoder must exceed about 100 MHz (unconfirmed).
9. "T" stands for Tuner. All the decoders are multi-tuner decoders.
10. Legacy decoders such as the SD PVR, 1110, 1131, 1132 etc MUST be connected to the legacy ports on the SLNB. HD PVR's (4U, 4P, 2U and 2P can be connected to the legacy ports with or without a MS as required.
11. A SLNB's power consumption on the Unicable ports is 600mA Max at 11-19 Volts. There are restrictions on which legacy decoders may be connected to the Unicable ports.
Typically a PACE 4P or PACE 2P decoder can only supply a maximum of 425mA at 13V- 18V DC. A Legacy decoder should not be connected to a SLNB unicable port on its own. A combination of at least one Explora and a legacy decoder is required to
prevent overloading.

Decoders LNB Power Capability combined. SLNB Power Consumption


mA DC Voltages Port mA DC Voltages
4U UEC HD PVR 4U (4660) 500 13 to 18 A-D 600 11V - 19V
4P PACE HD PVR 4P (850) 425 13 to 18 LEGACY 250 11V - 19V
4U,4S Zapper ?
2P PACE HD PVR 2P (865) 425 13 to 18
2U UEC HD PVR 2U (4828) ?
Explora ?

Anda mungkin juga menyukai