Anda di halaman 1dari 30

46

S P EC IALTY P RODUCTS

Centrifugal Filter Holders


C AP S U LE S AN D C ARTRI DG E S
• Durable, reusable unit for concentrating, desalting or purifying samples by centrifuge
• Compatible with most ø13 mm filters and ø30 mm centrifuge tubes (both sold separately)
• Easy to use units assemble quickly for repeated use Capsules – Introduction 48
PES Capsule Filter (CCS) 49
Unit diagram below.
PTFE Capsule Filters – Hydrophobic
S P E C I F I C AT I O N S (CCF) and Hydrophilic (CCFH) 50
• Housing: Acrylic, Polyacetal, Polypropylene Polypropylene Capsule Filter (CCP) 51
• Effective filtration area: 0.65 cm2 Glass Microfiber Capsule Filter (CCG) 52
• Maximum sample volume: 2 mL
• Minimum sample volume: 0.15 mL Cartridges – Introduction 53
• Maximum RCF: 19.6 x 103m/s2 (2,000 x g) End Fixture Configurations 54
UHP-13C Ultrafilter Unit
• Dead Volume: 0.01 mL
Cellulose Acetate Membrane (TCR) 55
Polyethersulfone (PES) Membrane (TCS) 56
O R D E R I N G I N F O R M AT I O N Polyethersulfone (PES) Membrane for the
Grade UHP-13C
Compatible filter size ø13 mm
Food and Beverage Industries (TCS-G) 57
Quantity per package* 1 Polyethersulfone (PES) Membrane for the
* Each unit includes 1 main body assembly, Electronics Industry (TCS-E) 58
12 cell caps, 12 filtrate caps, and 3 silicone O-rings.
Hydrophobic PTFE Membrane (TCF) 59
ACCESSORIES Hydrophilic PTFE Membrane (TCFH) 60
FPM O-ring UHP-13C-FPM
Coated Cellulose Acetate Membrane (TCY) 61
Quantity per package 1
Single Layer Coated Cellulose
Acetate Membrane (TCYE) 62
UHP-13C Unit Assembly USY Series Unit Assembly Polypropylene (TCP) 63
Single Layer Polypropylene (TCP/TCPE) 64
Multigrade Polypropylene (TCPD) 65
1
1. Cell Cap 1 1. Luer Cap
Epoxy Cellulose (TC) 66
2. Locking Nut 2. Luer Lock Inlet Glass Fiber (TCG)
2
3. Filter Cell
2
3. Cell Cap
68
3
4. Filter Holder O-ring 4. Silicone Check Valve All Polypropylene (OH) 69
5. Support Screen 5. Retentive Cell
4
3 6. Base Body 6. Ultrafilter String Wound (W) 70
7. Filtrate Cup 7. Filtrate Cell
SS Cartridge Housing – 1TS Type 71
4 5
5 SS Cartridge Housing – 1TM Type 72
6
6 Sanitary SS Cartridge Housing – 1TVA Type 73
Sanitary SS Cartridge Housing – 1TWA Type 74
7
7 Polypropylene Cartridge Housing
– 1PP Type 75
Acrylic Cartridge Housing – 1PA Type 76

800-334-7132 800-334-7132
48 49
C AP S U LE S C AP S U LE S

Capsules – Introduction PES Capsule Filter (CCS)


• All-polypropylene housing is sturdy and chemically • Can be sterilized by autoclaving (121°C, 30 min) or treatment with
compatible ethylene oxide (EtO)
• Three membrane-type media and two depth-type media • Available presterilized (EtO) or pre-rinsed (recommended when
• Wide range of retentive pore sizes filtering high purity water)
• All types available in three different lengths
• Diameter is a standard 78 mm A P P L I C AT I O N S
• Selected media available presterilized by ethylene oxide (EtO) • Filter pure water, high purity chemicals, pharmaceuticals,
cosmetics, and tissue culture media
A P P L I C AT I O N S • Remove bacteria or sub-micron particulates
• Filter tissue culture media, fermentation broth, and
ground water S P E C I F I C AT I O N S
• Can be set in serial mode to maximize throughput Maximum Inlet Pressure 0.39 MPa (57 psi)
volumes Maximum Operating Temperature 60°C (140°F)
• Point-of-use sterile filtration
Use capsules for pilot/prototype studies, scale up to W AT E R F L O W R AT E

Differential Pressure (MPa, [psi])



the same media in the cartridge format CCS-020 CCS-045 300

• Not recommended for air filtration Five different filter media are available in the capsule format. Layers Double Double
Pore Size (µm) 0.20 0.45 200

Minimum bubble point (water) ≥0.39 MPa (57 psi) ≥0.29 MPa (43 psi) 020
LRV / Organism ≥7 B. diminuta ≥7 S. marcescens
Media Code Characteristic Media type Pore Size or Membrane Filtration 100
Length Code Length (mm)* Filtration Area (cm2) 045
Nominal layers area per
Rating (µm) capsule (cm2) C 102 450
PES CCS hydrophilic membrane 0.20 – 0.45 double up to 1800 D 129 900 0 5 10 15 20
PTFE CCF hydrophobic membrane 0.05 – 1.0 single/double up to 3600 E 201 1800
Flow Rate (L/min)
PTFE CCFH hydrophilic membrane 0.20 single up to 3600 *Length given is for capsule with end fixture H.
Typical water flow rate for CCS-____-D1B at 25˚ C
Polypropylene CCP hydrophobic depth-type 0.8 – 30 N/A up to 2600
Glass CCG - depth-type 0.45 – 1.0 N/A up to 1200
For detailed chemical compatibility information, see page 116. O R D E R I N G I N F O R M AT I O N
When ordering length code “C”, end fixture code “D” is not available.
(S) 1
CCS - - 1 (R) 2

1
Pore size Pore Size Code Length (mm) Length Code End fixture End Fixture
(µm) (Inlet and Outlet) Code
0.20 020 102 C " NPTM
1/4 B
3
0.45 045 129 D " NPTM
1/2 D
4 201 E 3/8" hose barb H
2 11/2" sanitary N
5 D fitting
B
1/4" NPTM 1/2" NPTM 1. When ordering sterile units, specify “S” in the last position of the catalog number.
2. When ordering Pre-rinsed units, specify “R” in the last position of the catalog number.

1 1. Vent/drain (1/8" NPT)


2. Housing
3. End cap
4. Outer sleeve
5. Pleated filter media

H N
3/8" hose barb 1-1/2" sanitary fitting

800-334-7132 w w w. a d v a n t e c m f s . c o m
48 49
C AP S U LE S C AP S U LE S

Capsules – Introduction PES Capsule Filter (CCS)


• All-polypropylene housing is sturdy and chemically • Can be sterilized by autoclaving (121°C, 30 min) or treatment with
compatible ethylene oxide (EtO)
• Three membrane-type media and two depth-type media • Available presterilized (EtO) or pre-rinsed (recommended when
• Wide range of retentive pore sizes filtering high purity water)
• All types available in three different lengths
• Diameter is a standard 78 mm A P P L I C AT I O N S
• Selected media available presterilized by ethylene oxide (EtO) • Filter pure water, high purity chemicals, pharmaceuticals,
cosmetics, and tissue culture media
A P P L I C AT I O N S • Remove bacteria or sub-micron particulates
• Filter tissue culture media, fermentation broth, and
ground water S P E C I F I C AT I O N S
• Can be set in serial mode to maximize throughput Maximum Inlet Pressure 0.39 MPa (57 psi)
volumes Maximum Operating Temperature 60°C (140°F)
• Point-of-use sterile filtration
Use capsules for pilot/prototype studies, scale up to W AT E R F L O W R AT E

Differential Pressure (MPa, [psi])



the same media in the cartridge format CCS-020 CCS-045 300

• Not recommended for air filtration Five different filter media are available in the capsule format. Layers Double Double
Pore Size (µm) 0.20 0.45 200

Minimum bubble point (water) ≥0.39 MPa (57 psi) ≥0.29 MPa (43 psi) 020
LRV / Organism ≥7 B. diminuta ≥7 S. marcescens
Media Code Characteristic Media type Pore Size or Membrane Filtration 100
Length Code Length (mm)* Filtration Area (cm2) 045
Nominal layers area per
Rating (µm) capsule (cm2) C 102 450
PES CCS hydrophilic membrane 0.20 – 0.45 double up to 1800 D 129 900 0 5 10 15 20
PTFE CCF hydrophobic membrane 0.05 – 1.0 single/double up to 3600 E 201 1800
Flow Rate (L/min)
PTFE CCFH hydrophilic membrane 0.20 single up to 3600 *Length given is for capsule with end fixture H.
Typical water flow rate for CCS-____-D1B at 25˚ C
Polypropylene CCP hydrophobic depth-type 0.8 – 30 N/A up to 2600
Glass CCG - depth-type 0.45 – 1.0 N/A up to 1200
For detailed chemical compatibility information, see page 116. O R D E R I N G I N F O R M AT I O N
When ordering length code “C”, end fixture code “D” is not available.
(S) 1
CCS - - 1 (R) 2

1
Pore size Pore Size Code Length (mm) Length Code End fixture End Fixture
(µm) (Inlet and Outlet) Code
0.20 020 102 C " NPTM
1/4 B
3
0.45 045 129 D " NPTM
1/2 D
4 201 E 3/8" hose barb H
2 11/2" sanitary N
5 D fitting
B
1/4" NPTM 1/2" NPTM 1. When ordering sterile units, specify “S” in the last position of the catalog number.
2. When ordering Pre-rinsed units, specify “R” in the last position of the catalog number.

1 1. Vent/drain (1/8" NPT)


2. Housing
3. End cap
4. Outer sleeve
5. Pleated filter media

H N
3/8" hose barb 1-1/2" sanitary fitting

800-334-7132 w w w. a d v a n t e c m f s . c o m
50 51
C AP S U LE S C AP S U LE S

PTFE Capsule Filters – Hydrophobic (CCF) and Hydrophilic (CCFH) Polypropylene Capsule Filter (CCP)
• Compatible: solvent and pH-resistant • Hydrophilic: • Depth-type matrix: high dirt holding capacity, superior retention
• Hydrophobic: – Polyester membrane support • Compatible with aqueous solutions and solvents
– Supported membrane except CCF-A10 and CCF-005 – Single layer • Thermally welded to prevent fiber slough-off and minimize
– Single layer except CCF-A10 and CCF-005 which has double layer – 0.2 µm pore size changes in pore size during filtration
– 5 pore sizes • Wide range of particle size cut-offs
– Can be sterilized by autoclaving (121ºC, 30 min) or treatment with Note: Autoclaving or allowing mem- • Can be sterilized by autoclaving (121ºC, 30 min) or treatment
ethylene oxide (EtO). brane to dry will render it hydrophobic. with ethylene oxide (EtO).
W AT E R F L O W R AT E
A P P L I C AT I O N S W AT E R F L O W R AT E A P P L I C AT I O N S

Differential Pressure (MPa, [psi])


LX JX HX FX
• Use serially as prefilter and final filter CCF-005
• High purity water filtration 0.06
[8.7] 1

Differential Pressure (MPa, [psi])


0.3
• Corrosive fluids and gases, photoresists, and both alkalis and acids [43.5]
• Prefiltration to a final membrane filter such as PES or PTFE 3, 7, 10

(CCS, CCF, or CCFH) 30


• Hydrophobic: CCF-010 0.04
[5.8]
– Solvent filtration 0.2
• Ultracleaning
[29.0] CCF-A10
• Hydrophilic: • Filtration of process chemicals 0.02
[2.9]
– Solvents with higher surface tension CCF, CCFH-020
– Heterogeneous fluid mixtures 0.1
[14.5]
CCF-050
S P E C I F I C AT I O N S
0 5 10 15 20
CCF-100 Maximum Inlet Pressure 0.39 MPa (57 psi)
Flow Rate (L/min)
Maximum Operating Temperature 60°C (140°F)
S P E C I F I C AT I O N S 0 5 10 15 20 Typical water flow rate for CCP-____-D1B at 25˚C.
Maximum Inlet Pressure 0.39 MPa (57 psi) Flow Rate (L/min)

Maximum Operating Temperature 60°C (140°F) Typical water flow rate for CCF/CCFH-___-D1B at 25˚C
CCP-
LX JX HX FX 1 3 7 10 30
CCF-005 CCF-A10 CCF-010 CCF-020 CCF-050 CCF-100 CCFH-020 Particle size (µm) 0.8 1.0 2.0 3.0 2–5 5 – 10 10 – 20 10 – 20 20 - 30
Hydrophobic Hydrophilic % Particle
retention >99 >99 >99 >99 94 98 98 92 97
Layers Double Double Single Single Single Single Single
Length Length*
Pore size (µm) 0.05 0.10 0.10 0.20 0.50 1.0 0.20
Code (mm) Filtration Area (cm2)
Min. bubble
C 102 400 500 500 550 500 600 500 550 650
point (IPA)
MPa (psi) ≥0.16 (23) ≥0.15 (22) ≥0.13 (20) ≥0.09 (13) ≥0.05 (7) ≥0.03 (4) - D 129 800 1000 1000 1100 1000 1200 1000 1100 1300
Length Length* E 201 1600 2000 2000 2200 2000 2400 2000 2200 2600
Code (mm) Filtration Area (cm2) *Length given is for capsule with end fixture H.
C 102 900 900 570 570 570 570 900
D 129 1800 1800 1150 1150 1150 1150 1800 O R D E R I N G I N F O R M AT I O N
E 201 3600 3600 2300 2300 2300 2300 3600
*Length given is for capsule with end fixture H. CCP - - 1

O R D E R I N G I N F O R M AT I O N
Retention Characteristic Code Length (mm) Length Code End Fixtures End Fixture
(Inlet and Outlet) Code
CCF -
- 1 (S) 1 LX 102 C " NPTM
1/4 B
CCFH - JX 129 D " NPTM
1/2 D
HX 201 E 3/8" hose barb H
FX 11/2" sanitary N
Pore Size Pore Size Code Pore Size Pore Size Code Length (mm) Length Code End Fixtures End Fixture 1 fitting
(µm) (µm) (Inlet and Outlet) Code
3
0.05 005 0.2 020 102 C 1/4" NPTM B 7
0.10 A10 129 D 1/2" NPTM D 10
0.10 010 201 E 3/8" hose barb H 30
0.20 020 11/2" sanitary N
0.50 050 fitting
1.00 100
1. When ordering sterile units, specify “S” in the last position of the catalog number.

800-334-7132 w w w. a d v a n t e c m f s . c o m
50 51
C AP S U LE S C AP S U LE S

PTFE Capsule Filters – Hydrophobic (CCF) and Hydrophilic (CCFH) Polypropylene Capsule Filter (CCP)
• Compatible: solvent and pH-resistant • Hydrophilic: • Depth-type matrix: high dirt holding capacity, superior retention
• Hydrophobic: – Polyester membrane support • Compatible with aqueous solutions and solvents
– Supported membrane except CCF-A10 and CCF-005 – Single layer • Thermally welded to prevent fiber slough-off and minimize
– Single layer except CCF-A10 and CCF-005 which has double layer – 0.2 µm pore size changes in pore size during filtration
– 5 pore sizes • Wide range of particle size cut-offs
– Can be sterilized by autoclaving (121ºC, 30 min) or treatment with Note: Autoclaving or allowing mem- • Can be sterilized by autoclaving (121ºC, 30 min) or treatment
ethylene oxide (EtO). brane to dry will render it hydrophobic. with ethylene oxide (EtO).
W AT E R F L O W R AT E
A P P L I C AT I O N S W AT E R F L O W R AT E A P P L I C AT I O N S

Differential Pressure (MPa, [psi])


LX JX HX FX
• Use serially as prefilter and final filter CCF-005
• High purity water filtration 0.06
[8.7] 1

Differential Pressure (MPa, [psi])


0.3
• Corrosive fluids and gases, photoresists, and both alkalis and acids [43.5]
• Prefiltration to a final membrane filter such as PES or PTFE 3, 7, 10

(CCS, CCF, or CCFH) 30


• Hydrophobic: CCF-010 0.04
[5.8]
– Solvent filtration 0.2
• Ultracleaning
[29.0] CCF-A10
• Hydrophilic: • Filtration of process chemicals 0.02
[2.9]
– Solvents with higher surface tension CCF, CCFH-020
– Heterogeneous fluid mixtures 0.1
[14.5]
CCF-050
S P E C I F I C AT I O N S
0 5 10 15 20
CCF-100 Maximum Inlet Pressure 0.39 MPa (57 psi)
Flow Rate (L/min)
Maximum Operating Temperature 60°C (140°F)
S P E C I F I C AT I O N S 0 5 10 15 20 Typical water flow rate for CCP-____-D1B at 25˚C.
Maximum Inlet Pressure 0.39 MPa (57 psi) Flow Rate (L/min)

Maximum Operating Temperature 60°C (140°F) Typical water flow rate for CCF/CCFH-___-D1B at 25˚C
CCP-
LX JX HX FX 1 3 7 10 30
CCF-005 CCF-A10 CCF-010 CCF-020 CCF-050 CCF-100 CCFH-020 Particle size (µm) 0.8 1.0 2.0 3.0 2–5 5 – 10 10 – 20 10 – 20 20 - 30
Hydrophobic Hydrophilic % Particle
retention >99 >99 >99 >99 94 98 98 92 97
Layers Double Double Single Single Single Single Single
Length Length*
Pore size (µm) 0.05 0.10 0.10 0.20 0.50 1.0 0.20
Code (mm) Filtration Area (cm2)
Min. bubble
C 102 400 500 500 550 500 600 500 550 650
point (IPA)
MPa (psi) ≥0.16 (23) ≥0.15 (22) ≥0.13 (20) ≥0.09 (13) ≥0.05 (7) ≥0.03 (4) - D 129 800 1000 1000 1100 1000 1200 1000 1100 1300
Length Length* E 201 1600 2000 2000 2200 2000 2400 2000 2200 2600
Code (mm) Filtration Area (cm2) *Length given is for capsule with end fixture H.
C 102 900 900 570 570 570 570 900
D 129 1800 1800 1150 1150 1150 1150 1800 O R D E R I N G I N F O R M AT I O N
E 201 3600 3600 2300 2300 2300 2300 3600
*Length given is for capsule with end fixture H. CCP - - 1

O R D E R I N G I N F O R M AT I O N
Retention Characteristic Code Length (mm) Length Code End Fixtures End Fixture
(Inlet and Outlet) Code
CCF -
- 1 (S) 1 LX 102 C " NPTM
1/4 B
CCFH - JX 129 D " NPTM
1/2 D
HX 201 E 3/8" hose barb H
FX 11/2" sanitary N
Pore Size Pore Size Code Pore Size Pore Size Code Length (mm) Length Code End Fixtures End Fixture 1 fitting
(µm) (µm) (Inlet and Outlet) Code
3
0.05 005 0.2 020 102 C 1/4" NPTM B 7
0.10 A10 129 D 1/2" NPTM D 10
0.10 010 201 E 3/8" hose barb H 30
0.20 020 11/2" sanitary N
0.50 050 fitting
1.00 100
1. When ordering sterile units, specify “S” in the last position of the catalog number.

800-334-7132 w w w. a d v a n t e c m f s . c o m
52 53
C AP S U LE S C ARTRI DG E S

Glass Microfiber Capsule Filter (CCG) Cartridges – Introduction


• Depth-type matrix of borosilicate glass microfiber • Available in a wide variety of media and end fixture
• Large dirt holding capacity configurations
• Resistant to most fluids except strong acids • Media can be mixed and configured in serial format
• Contains a small amount of acrylic resin binder to enhance wet strength to maximize throughput volumes, flow rates, and
• Can be sterilized by autoclaving (121ºC, 30 min) or treatment with ethylene oxide (EtO). cartridge life
• Fit many commercially available filter housings
A P P L I C AT I O N S
• Sea water filtration A P P L I C AT I O N S
• Aquaculture • Large surface area permits large throughput volumes
• Prefiltration to a final membrane filter such as PES or PTFE (CCS, CCF, or CCFH) and higher flow rates
• Suitable for both prefiltration and final filtration of
S P E C I F I C AT I O N S fluids in pharmaceutical, food, beverage, and electronics
Maximum Inlet Pressure 0.29 MPa (43 psi) W AT E R F L O W R AT E industries
• Wide choice of media and core enables use in many Eleven different filter media are available in cartridge format.

Differential Pressure (MPa, [psi])


Maximum Operating Temperature 60°C (140°F) 045 1
0.06 chemical and thermal conditions
[8.7]

CCG-045 CCG-1 0.04


S P E C I F I C AT I O N S
[5.8]
Nominal Pore Media Code Media type Format Absolute/ Pore Size or Metric/
Size (µm) 1 – 1.5 µm 1.5 – 2.0 µm Nominal Rating (µm) English
0.02
Length Length* [2.9] lengths 1
Code (mm) Filtration Area (cm2) Cellulose acetate TCR Membrane Pleated, internal prefilter Absolute 0.20 – 0.80 Metric
C 102 300 Polyethersulfone (PES) TCS Membrane Pleated, internal prefilter Absolute 0.20 – 0.45 Metric
0 5 10 15 20
D 129 600 Polyethersulfone (PES) TCS-G Membrane Pleated, internal prefilter Absolute 0.20 – 0.65 Metric 2
Flow Rate (L/min)
E 201 1200 Polyethersulfone (PES) TCS-E Membrane Pleated, internal prefilter Absolute 0.20 – 0.45 Metric
Typical water flow rate for CCG-____-D1B at 25˚C. 3
*Length given is for capsule with end fixture H. Hydrophobic PTFE TCF Membrane Pleated Absolute 0.05 – 1.0 Metric
Hydrophilic PTFE TCFH Membrane Pleated Absolute 0.10 – 1.0 Metric 2
Coated cellulose acetate TCY Membrane Pleated, dual layer Nominal 0.21 – 2.0 Metric
O R D E R I N G I N F O R M AT I O N 4
Coated cellulose acetate TCYE Membrane Pleated, single layer Nominal 0.21 – 10 Metric
Polypropylene TCP Bonded fiber Pleated, multiple layers Nominal 0.8 – 3.0 Metric
CCG - - 1 Polypropylene TCP/TCPE Bonded fiber Pleated, single layer Nominal 1 – 30 Metric 5
Polypropylene, multigrade TCPD Depth-type Spirally wound Nominal 1 – 70 Metric
Epoxy cellulose TC Depth-type Pleated Nominal 1 – 30 Metric
Nominal Pore Nominal Pore Length Length End Fixtures End Fixture Glass fiber TCG Depth-type Pleated, dual layer Nominal 0.45 – 1 Metric
Size (µm) Size Code (mm) Code (Inlet and Outlet) Code All-polypropylene OH Bonded fiber Graded density Nominal 1 – 75 English
0.45 045 102 C " NPTM 1/4 B String (11 types of media) W String fiber String wound Nominal 0.5 – 200 English
1.0 1 129 D " NPTM 1/2 D
201 E 3/8" hose barb H 1. End cap
Gasket/O-ring Gasket/O-ring Autoclavable Max Temp.
11/2" sanitary N Polymer Code (°C) 2. Support media
fitting 3. Final membrane
EPR E O 150
EPDM D O 150 4. Core tube
Chloroprene N X 120 5. Outer sleeve
NBR B X 130
Silicone S O 230
FPM V O 260
PTFE (Gasket only) H O 260
FEP Encapsulated (O-ring only) F O 260
O – Recommended X – Not recommended

For detailed chemical compatibility information, see page 126.


Filter housings are available – call to discuss your particular needs.

800-334-7132 w w w. a d v a n t e c m f s . c o m
52 53
C AP S U LE S C ARTRI DG E S

Glass Microfiber Capsule Filter (CCG) Cartridges – Introduction


• Depth-type matrix of borosilicate glass microfiber • Available in a wide variety of media and end fixture
• Large dirt holding capacity configurations
• Resistant to most fluids except strong acids • Media can be mixed and configured in serial format
• Contains a small amount of acrylic resin binder to enhance wet strength to maximize throughput volumes, flow rates, and
• Can be sterilized by autoclaving (121ºC, 30 min) or treatment with ethylene oxide (EtO). cartridge life
• Fit many commercially available filter housings
A P P L I C AT I O N S
• Sea water filtration A P P L I C AT I O N S
• Aquaculture • Large surface area permits large throughput volumes
• Prefiltration to a final membrane filter such as PES or PTFE (CCS, CCF, or CCFH) and higher flow rates
• Suitable for both prefiltration and final filtration of
S P E C I F I C AT I O N S fluids in pharmaceutical, food, beverage, and electronics
Maximum Inlet Pressure 0.29 MPa (43 psi) W AT E R F L O W R AT E industries
• Wide choice of media and core enables use in many Eleven different filter media are available in cartridge format.

Differential Pressure (MPa, [psi])


Maximum Operating Temperature 60°C (140°F) 045 1
0.06 chemical and thermal conditions
[8.7]

CCG-045 CCG-1 0.04


S P E C I F I C AT I O N S
[5.8]
Nominal Pore Media Code Media type Format Absolute/ Pore Size or Metric/
Size (µm) 1 – 1.5 µm 1.5 – 2.0 µm Nominal Rating (µm) English
0.02
Length Length* [2.9] lengths 1
Code (mm) Filtration Area (cm2) Cellulose acetate TCR Membrane Pleated, internal prefilter Absolute 0.20 – 0.80 Metric
C 102 300 Polyethersulfone (PES) TCS Membrane Pleated, internal prefilter Absolute 0.20 – 0.45 Metric
0 5 10 15 20
D 129 600 Polyethersulfone (PES) TCS-G Membrane Pleated, internal prefilter Absolute 0.20 – 0.65 Metric 2
Flow Rate (L/min)
E 201 1200 Polyethersulfone (PES) TCS-E Membrane Pleated, internal prefilter Absolute 0.20 – 0.45 Metric
Typical water flow rate for CCG-____-D1B at 25˚C. 3
*Length given is for capsule with end fixture H. Hydrophobic PTFE TCF Membrane Pleated Absolute 0.05 – 1.0 Metric
Hydrophilic PTFE TCFH Membrane Pleated Absolute 0.10 – 1.0 Metric 2
Coated cellulose acetate TCY Membrane Pleated, dual layer Nominal 0.21 – 2.0 Metric
O R D E R I N G I N F O R M AT I O N 4
Coated cellulose acetate TCYE Membrane Pleated, single layer Nominal 0.21 – 10 Metric
Polypropylene TCP Bonded fiber Pleated, multiple layers Nominal 0.8 – 3.0 Metric
CCG - - 1 Polypropylene TCP/TCPE Bonded fiber Pleated, single layer Nominal 1 – 30 Metric 5
Polypropylene, multigrade TCPD Depth-type Spirally wound Nominal 1 – 70 Metric
Epoxy cellulose TC Depth-type Pleated Nominal 1 – 30 Metric
Nominal Pore Nominal Pore Length Length End Fixtures End Fixture Glass fiber TCG Depth-type Pleated, dual layer Nominal 0.45 – 1 Metric
Size (µm) Size Code (mm) Code (Inlet and Outlet) Code All-polypropylene OH Bonded fiber Graded density Nominal 1 – 75 English
0.45 045 102 C " NPTM 1/4 B String (11 types of media) W String fiber String wound Nominal 0.5 – 200 English
1.0 1 129 D " NPTM 1/2 D
201 E 3/8" hose barb H 1. End cap
Gasket/O-ring Gasket/O-ring Autoclavable Max Temp.
11/2" sanitary N Polymer Code (°C) 2. Support media
fitting 3. Final membrane
EPR E O 150
EPDM D O 150 4. Core tube
Chloroprene N X 120 5. Outer sleeve
NBR B X 130
Silicone S O 230
FPM V O 260
PTFE (Gasket only) H O 260
FEP Encapsulated (O-ring only) F O 260
O – Recommended X – Not recommended

For detailed chemical compatibility information, see page 126.


Filter housings are available – call to discuss your particular needs.

800-334-7132 w w w. a d v a n t e c m f s . c o m
54 55
C ARTRI DG E S C ARTRI DG E S

End Fixture Configurations Cellulose Acetate (TCR)


Twelve different end configurations are pictured below; see the individual cartridge listings for availability. All-polypropylene • Dual cellulose acetate membranes provide internal prefiltration by placing
(OH) and string wound (W) cartridges have a compression seal (not pictured), eliminating the need for gaskets or O-rings. a larger pore size membrane upstream of final rated pore size membrane
• Polyester membrane support is non-fiber releasing
• Low protein binding

A P P L I C AT I O N S
• Filter ultra-pure water, rinse waters, cosmetics, pharmaceuticals,
and beverages (beer and wine)

S P E C I F I C AT I O N S Materials:
TCR-020 TCR-045 TCR-080 End cap Polybutyleneterephthalate (PBT)

H Size 222 heat-resistant O-ring,


flat closed
Standard O-ring: Silicone
M Size 222 O-ring, flat closed
Standard O-ring: EPR
Note: Non-Autoclavable
L Size 222 O-ring with internal
stainless steel support, flat closed
Available for TCR-type only
Pore size
Dual membranes:
0.20 µm 0.45 µm 0.80 µm Sealing material
Support media
Medical grade polyurethane
Polyester
Note: Autoclavable Note: Autoclavable Upstream 0.80 µm 0.80 µm 5.0 µm Prefilter membrane Cellulose acetate
Downstream 0.20 µm 0.45 µm 0.80 µm Final membrane Cellulose acetate
Challenge organism B. diminuta S. marcescens S. cerevisiae Core tube Polypropylene
LRV (Log reduction value) ≥7 ≥7 ≥7 Outer sleeve Polypropylene
Bubble Point (MPa) ≥0.294 ≥0.235 ≥0.088
Filtration area per single length 4200 cm2
Max. differential pressure (25°C) 0.39 MPa (57 psi)
Max. operating temperature 80°C (176°F)

O R D E R I N G I N F O R M AT I O N

K Size 222 heat-resistant O-ring,


spear closed
Standard O-ring: Silicone
R Size 222 O-ring, spear closed
Standard O-ring: EPR
Note: Non-Autoclavable
S Size 222 O-ring with tabs and
internal stainless steel support,
spear closed
TCR - - B
Note: Autoclavable Available for TCR-type only
Note: Autoclavable

Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring
(µm) Code (mm) Code Code Polymer Code
0.20 020 250 (single) S F R EPR E (standard)
0.45 045 500 (double) D N S EPDM D
0.80 080 750 (triple) T M P Chloroprene N
1000 (quad) Q L Q NBR B
Note: Codes N, L, Q, and S are Silicone S
autoclavable at 121ºC, 30 min.
FPM V

J Size 226 heat-resistant O-ring


with tabs, spear closed
Standard O-ring: Silicone
P Size 226 O-ring with tabs,
spear closed
Standard O-ring: EPR
Q Size 226 O-ring with tabs and
internal stainless steel support,
spear closed
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
Note: Autoclavable Note: Non-Autoclavable Available TCR-type only 100
4
[0.58]

Differential Pressure (kPa [psi])


Note: Autoclavable [14.5]

Differential Pressure (kPa [psi])


80 3
[11.6] [0.43] TCR-020

TCR-020
60
[8.7] 2
TCR-045
[0.29] TCR-045

40
[5.8]
1
[0.14]
TCR-080
20
[2.9]
TCR-080

0 100 200 300 400 500

F N 120 size O-ring


C Flat Gasket 0 10 20 30 40
Flat Gasket
Standard O-ring: Silicone Standard Gasket: Chloroprene Flow Rate (N L/min/250 mm length)
Standard Gasket: EPR Flow Rate (L/min/250 mm length) Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Note: Non-Autoclavable Note: Autoclavable (for PP) or NBR (for SS) Conditions: Pipe dia. 3/4 in., Water temp. 20°C
Available for TC-type only
Note: Non-Autoclavable
800-334-7132 w w w. a d v a n t e c m f s . c o m
54 55
C ARTRI DG E S C ARTRI DG E S

End Fixture Configurations Cellulose Acetate (TCR)


Twelve different end configurations are pictured below; see the individual cartridge listings for availability. All-polypropylene • Dual cellulose acetate membranes provide internal prefiltration by placing
(OH) and string wound (W) cartridges have a compression seal (not pictured), eliminating the need for gaskets or O-rings. a larger pore size membrane upstream of final rated pore size membrane
• Polyester membrane support is non-fiber releasing
• Low protein binding

A P P L I C AT I O N S
• Filter ultra-pure water, rinse waters, cosmetics, pharmaceuticals,
and beverages (beer and wine)

S P E C I F I C AT I O N S Materials:
TCR-020 TCR-045 TCR-080 End cap Polybutyleneterephthalate (PBT)

H Size 222 heat-resistant O-ring,


flat closed
Standard O-ring: Silicone
M Size 222 O-ring, flat closed
Standard O-ring: EPR
Note: Non-Autoclavable
L Size 222 O-ring with internal
stainless steel support, flat closed
Available for TCR-type only
Pore size
Dual membranes:
0.20 µm 0.45 µm 0.80 µm Sealing material
Support media
Medical grade polyurethane
Polyester
Note: Autoclavable Note: Autoclavable Upstream 0.80 µm 0.80 µm 5.0 µm Prefilter membrane Cellulose acetate
Downstream 0.20 µm 0.45 µm 0.80 µm Final membrane Cellulose acetate
Challenge organism B. diminuta S. marcescens S. cerevisiae Core tube Polypropylene
LRV (Log reduction value) ≥7 ≥7 ≥7 Outer sleeve Polypropylene
Bubble Point (MPa) ≥0.294 ≥0.235 ≥0.088
Filtration area per single length 4200 cm2
Max. differential pressure (25°C) 0.39 MPa (57 psi)
Max. operating temperature 80°C (176°F)

O R D E R I N G I N F O R M AT I O N

K Size 222 heat-resistant O-ring,


spear closed
Standard O-ring: Silicone
R Size 222 O-ring, spear closed
Standard O-ring: EPR
Note: Non-Autoclavable
S Size 222 O-ring with tabs and
internal stainless steel support,
spear closed
TCR - - B
Note: Autoclavable Available for TCR-type only
Note: Autoclavable

Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring
(µm) Code (mm) Code Code Polymer Code
0.20 020 250 (single) S F R EPR E (standard)
0.45 045 500 (double) D N S EPDM D
0.80 080 750 (triple) T M P Chloroprene N
1000 (quad) Q L Q NBR B
Note: Codes N, L, Q, and S are Silicone S
autoclavable at 121ºC, 30 min.
FPM V

J Size 226 heat-resistant O-ring


with tabs, spear closed
Standard O-ring: Silicone
P Size 226 O-ring with tabs,
spear closed
Standard O-ring: EPR
Q Size 226 O-ring with tabs and
internal stainless steel support,
spear closed
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
Note: Autoclavable Note: Non-Autoclavable Available TCR-type only 100
4
[0.58]

Differential Pressure (kPa [psi])


Note: Autoclavable [14.5]

Differential Pressure (kPa [psi])


80 3
[11.6] [0.43] TCR-020

TCR-020
60
[8.7] 2
TCR-045
[0.29] TCR-045

40
[5.8]
1
[0.14]
TCR-080
20
[2.9]
TCR-080

0 100 200 300 400 500

F N 120 size O-ring


C Flat Gasket 0 10 20 30 40
Flat Gasket
Standard O-ring: Silicone Standard Gasket: Chloroprene Flow Rate (N L/min/250 mm length)
Standard Gasket: EPR Flow Rate (L/min/250 mm length) Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Note: Non-Autoclavable Note: Autoclavable (for PP) or NBR (for SS) Conditions: Pipe dia. 3/4 in., Water temp. 20°C
Available for TC-type only
Note: Non-Autoclavable
800-334-7132 w w w. a d v a n t e c m f s . c o m
56 57
C ARTRI DG E S C ARTRI DG E S

Polyethersulfone (PES) Membrane (TCS) Polyethersulfone (PES) Membrane for the Food and Beverage Industries (TCS-G)
• Dual Polyethersulfone (PES) membranes provide internal A P P L I C AT I O N S •Dual Polyethersulfone (PES) membranes provide internal A P P L I C AT I O N S
prefiltration by placing a larger pore size membrane • Filtration for electronics, cosmetics, pharmaceuticals prefiltration by placing a larger pore size membrane • Food and beverage Industries
upstream of final rated pore size membrane and beverage Industries upstream of final rated pore size membrane
• Low extractables • Low extractables
• Enhanced chemical compatibility • Enhanced chemical compatibility
• Quick rinse down • Quick rinse down
• Low protein binding • Low protein binding
• 100% integrity tested during manufacturing • 100% integrity tested during manufacturing
• Non-fiber releasing • Non-fiber releasing
• Selected types may be hot water sanitized
S P E C I F I C AT I O N S Materials:
TCS-020 TCS-045 End cap Polypropylene S P E C I F I C AT I O N S Materials:
Pore size 0.20 µm 0.45 µm Support media Polypropylene TCS-G020 TCS-G045 TCS-G065 End cap Polypropylene
Dual membranes: Prefilter membrane Polytethersulfone (PES) Pore size 0.20 µm 0.45 µm 0.65 µm Support media Polypropylene
Upstream 0.45 µm 0.65 µm Final membrane Polytethersulfone (PES) Challenge Organism B.diminuta S.marcescens S.cerevisiae Prefilter membrane Polytethersulfone (PES)
Downstream 0.20 µm 0.45 µm Core tube Polypropylene LRV (Log reduction value) ≥7 ≥7 ≥7 Final membrane Polytethersulfone (PES)
Challenge organism B. diminuta S. marcescens Outer sleeve Polypropylene Max. differential pressure (25°C) 0.39 MPa [57 psi] Core tube Polypropylene
LRV (Log reduction value) ≥7 ≥7 Max. operating temperature 80°C (176°F) Outer sleeve Polypropylene
Filtration area per single length 4000 cm2 Filtration area (with 250 mm) 6600 cm2
Max. differential pressure (25°C) 0.39 MPa (57 psi) Diffusion Rate (with 250 mm) <55 mL/min <53 mL/min
<40 mL/min
Max. operating temperature 80°C (176°F) at 0.326 MPa at 0.206 MPa at 0.100 MPa

O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N

TCS - - 1 TCS-G - - 1

Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring
(µm) Code (mm) Code Code Polymer Code (µm) Code (mm) Code Code Polymer Code
0.20 020 250 (single) S F R EPR E (standard) 0.20 020 250 (single) S F R EPR E
0.45 045 500 (double) D N K EPDM D 0.45 045 500 (double) D K EPDM D
750 (triple) T M P Chloroprene N 0.65 065 750 (triple) T M P Chloroprene N
1000 (quad) Q H J NBR B 1000 (quad) Q H J NBR B
Note: Codes H, J, K, and N are Silicone S Note: Codes H, K, and J may be hot water Silicone S (standard)
autoclavable at 121ºC, 30 min. FPM V sanitized at 85ºC for 30 min, up to 100
FPM V
times.

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
2
50 [0.29]
Differential Pressure (kPa [psi])

2.0

Differential Pressure (kPa [psi])


[7.2] [0.29]
Differential Pressure (kPa [psi])

TCS-020 40

Differential Pressure (kPa [psi])


[5.8] TCS-G020
TCS-G020
40
[5.8] TCS-020 1.5
30 [0.22]
[4.3]
TCS-G045
30 TCS-045 TCS-G045
1
[4.3]
[0.14] 20 1
[2.9] [0.14]
TCS-045
20
[2.9] TCS-G065
10
TCS-G065 0.5
[1.4]
[0.07]
10
[1.4]
0 10 20 30 40
0 100 200 300 400 500
0 100 200 300 400 500
0 10 20 30 40 Flow Rate (N L/min/250 mm length) Flow Rate (L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C Conditions: Pipe dia. 3/4 in., Water temp. 20°C Flow Rate (N L/min/250 mm length)
Flow Rate (L/min/250 mm length) Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Conditions: Pipe dia. 3/4 in., Water temp. 20°C

800-334-7132 800-334-7132
56 57
C ARTRI DG E S C ARTRI DG E S

Polyethersulfone (PES) Membrane (TCS) Polyethersulfone (PES) Membrane for the Food and Beverage Industries (TCS-G)
• Dual Polyethersulfone (PES) membranes provide internal A P P L I C AT I O N S •Dual Polyethersulfone (PES) membranes provide internal A P P L I C AT I O N S
prefiltration by placing a larger pore size membrane • Filtration for electronics, cosmetics, pharmaceuticals prefiltration by placing a larger pore size membrane • Food and beverage Industries
upstream of final rated pore size membrane and beverage Industries upstream of final rated pore size membrane
• Low extractables • Low extractables
• Enhanced chemical compatibility • Enhanced chemical compatibility
• Quick rinse down • Quick rinse down
• Low protein binding • Low protein binding
• 100% integrity tested during manufacturing • 100% integrity tested during manufacturing
• Non-fiber releasing • Non-fiber releasing
• Selected types may be hot water sanitized
S P E C I F I C AT I O N S Materials:
TCS-020 TCS-045 End cap Polypropylene S P E C I F I C AT I O N S Materials:
Pore size 0.20 µm 0.45 µm Support media Polypropylene TCS-G020 TCS-G045 TCS-G065 End cap Polypropylene
Dual membranes: Prefilter membrane Polytethersulfone (PES) Pore size 0.20 µm 0.45 µm 0.65 µm Support media Polypropylene
Upstream 0.45 µm 0.65 µm Final membrane Polytethersulfone (PES) Challenge Organism B.diminuta S.marcescens S.cerevisiae Prefilter membrane Polytethersulfone (PES)
Downstream 0.20 µm 0.45 µm Core tube Polypropylene LRV (Log reduction value) ≥7 ≥7 ≥7 Final membrane Polytethersulfone (PES)
Challenge organism B. diminuta S. marcescens Outer sleeve Polypropylene Max. differential pressure (25°C) 0.39 MPa [57 psi] Core tube Polypropylene
LRV (Log reduction value) ≥7 ≥7 Max. operating temperature 80°C (176°F) Outer sleeve Polypropylene
Filtration area per single length 4000 cm2 Filtration area (with 250 mm) 6600 cm2
Max. differential pressure (25°C) 0.39 MPa (57 psi) Diffusion Rate (with 250 mm) <55 mL/min <53 mL/min
<40 mL/min
Max. operating temperature 80°C (176°F) at 0.326 MPa at 0.206 MPa at 0.100 MPa

O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N

TCS - - 1 TCS-G - - 1

Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring
(µm) Code (mm) Code Code Polymer Code (µm) Code (mm) Code Code Polymer Code
0.20 020 250 (single) S F R EPR E (standard) 0.20 020 250 (single) S F R EPR E
0.45 045 500 (double) D N K EPDM D 0.45 045 500 (double) D K EPDM D
750 (triple) T M P Chloroprene N 0.65 065 750 (triple) T M P Chloroprene N
1000 (quad) Q H J NBR B 1000 (quad) Q H J NBR B
Note: Codes H, J, K, and N are Silicone S Note: Codes H, K, and J may be hot water Silicone S (standard)
autoclavable at 121ºC, 30 min. FPM V sanitized at 85ºC for 30 min, up to 100
FPM V
times.

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
2
50 [0.29]
Differential Pressure (kPa [psi])

2.0

Differential Pressure (kPa [psi])


[7.2] [0.29]
Differential Pressure (kPa [psi])

TCS-020 40

Differential Pressure (kPa [psi])


[5.8] TCS-G020
TCS-G020
40
[5.8] TCS-020 1.5
30 [0.22]
[4.3]
TCS-G045
30 TCS-045 TCS-G045
1
[4.3]
[0.14] 20 1
[2.9] [0.14]
TCS-045
20
[2.9] TCS-G065
10
TCS-G065 0.5
[1.4]
[0.07]
10
[1.4]
0 10 20 30 40
0 100 200 300 400 500
0 100 200 300 400 500
0 10 20 30 40 Flow Rate (N L/min/250 mm length) Flow Rate (L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C Conditions: Pipe dia. 3/4 in., Water temp. 20°C Flow Rate (N L/min/250 mm length)
Flow Rate (L/min/250 mm length) Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Conditions: Pipe dia. 3/4 in., Water temp. 20°C

800-334-7132 800-334-7132
58 59
C ARTRI DG E S C ARTRI DG E S

Polyethersulfone (PES) Membrane for the Electronics Industr y (TCS-E) Hydrophobic PTFE (TCF)
• Dual Polyethersulfone (PES) membranes provide internal A P P L I C AT I O N S • PTFE membrane supported on a non-fiber releasing A P P L I C AT I O N S
prefiltration by placing a larger pore size membrane • Filtration for electronics Industry polypropylene backing • Filtration of photo resists and organic solvents
upstream of final rated pore size membrane • Enhanced chemical resistance • Uses in the electronics industry and in chemical
• Low extractables • Selected types may be in-line steam sterilized (126°C, manufacturing
• Enhanced chemical compatibility 30 min) or autoclaved (121°C, 30 min) • Filtering gases and venting tanks
• Quick rinse down
• 100% integrity tested during manufacturing Note: Process fluids must have a surface tension of <32 mN/m (dyne/cm) to properly wet the filter and to achieve
• Non-fiber releasing optimized flow rates and performance characteristics. For fluids with a surface tension ≥ 32 mN/m (dyne/cm), use
• Superior recovery of resistivity and TOC since hydrophilic PTFE (TCFH-type cartridges).
cartridges are individually flushed with pure water in
the manufacturing process S P E C I F I C AT I O N S Materials:
TCF-005 TCF-010 TCF-020 TCF-050 TCF-100 TCF-020L End cap Polypropylene
S P E C I F I C AT I O N S Materials: Pore size 0.05 µm 0.10 µm 0.20 µm 0.50 µm 1.00 µm 0.20 µm Support media Polypropylene
TCS-E020 TCS-E045 TCS-E045S TCS-E-020/045 TCS-E-045S Filtration area per single length 9200 cm2 9200 cm2 7000 cm2 7000 cm2 7000 cm2 16,400 cm2 Membrane PTFE
Pore size 0.20 µm 0.45 µm 0.45 µm End cap Polypropylene Polypropylene Max. differential pressure (25°C) 0.39 MPa (57 psi) 0.25 MPa (36 psi) Core tube Polypropylene
Filtration area (with 250 mm) 6700 cm2 8800 cm2 Support media Polypropylene Polypropylene Max. operating temperature 80°C (176°F) 40°C (104°F) Outer sleeve Polypropylene
Max. differential pressure (25°C) 0.39 MPa [57 psi] Prefilter membrane Polytethersulfone (PES) -
Max. operating temperature 80°C (176°F) Final membrane Polytethersulfone (PES) Polyethersulfone (PES) O R D E R I N G I N F O R M AT I O N
Core tube Polypropylene Polypropylene
Outer sleeve Polypropylene Polypropylene TCF - 0 2 0 L - *1 3 *2
TCF - - 1
O R D E R I N G I N F O R M AT I O N

TCS-E - - 1
Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring
(µm) Code (mm) Code Code Polymer Code
0.05 005 250 (single) S F R EPR E (standard)
Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring 0.10 010 500 (double) D N K EPDM D
(µm) Code (mm) Code Code Polymer Code 0.20 020 750 (triple) T M P Chloroprene N
0.20 020 250 (single) S F R EPR E (standard) 0.50 050 1000 (quad) Q H J NBR B
0.45 045 500 (double) D M P EPDM D 1.00 100 *1 Available with length codes Note: Codes H, J, K, and N are Silicone S
0.45 045S 750 (triple) T Chloroprene N S, D, and T. autoclavable at 121ºC, 30 min, or can FPM V
be steam sterilized at 126ºC for 30 min.
1000 (quad) Q NBR B PTFE H (Gasket only)
*2 Available with end fixture codes
Silicone S F, M, R, and P. FEP F (O-ring only)
Encapsulated
FPM V

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
25
TCF-005 TCF-005
[3.6] TCS-E020 TCF-010
Differential Pressure (kPa [psi])

0.8
100
[0.11]
Differential Pressure (kPa [psi])

[14.5] 1.0

Differential Pressure (kPa [psi])

Differential Pressure (kPa [psi])


[0.14]
20 TCS-E020
TCF-020
[2.9]
0.6 80
[11.6] 0.8
[0.09] [0.12]
15
[2.2] TCF-050
TCS-E045 60 TCF-010
0.6
0.4 [8.7]
[0.09] TCF-020L
[0.06] TCS-E045
10
TCF-100
[1.4]
TCS-E045S 40 0.4
TCS-E045S
[5.8] TCF-020 [0.06]
TCF-050
0.2
5 [0.03] TCF-020L
[0.7] 20 TCF-100 0.2
[2.9] [0.03]

0 10 20 30 40 0 100 200 300 400 500


0 10 20 30 40 0 100 200 300 400 500
Flow Rate (L/min/250 mm length) Flow Rate (L/min/250 mm length) Flow Rate (L/min/250 mm length) Flow Rate (L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
58 59
C ARTRI DG E S C ARTRI DG E S

Polyethersulfone (PES) Membrane for the Electronics Industr y (TCS-E) Hydrophobic PTFE (TCF)
• Dual Polyethersulfone (PES) membranes provide internal A P P L I C AT I O N S • PTFE membrane supported on a non-fiber releasing A P P L I C AT I O N S
prefiltration by placing a larger pore size membrane • Filtration for electronics Industry polypropylene backing • Filtration of photo resists and organic solvents
upstream of final rated pore size membrane • Enhanced chemical resistance • Uses in the electronics industry and in chemical
• Low extractables • Selected types may be in-line steam sterilized (126°C, manufacturing
• Enhanced chemical compatibility 30 min) or autoclaved (121°C, 30 min) • Filtering gases and venting tanks
• Quick rinse down
• 100% integrity tested during manufacturing Note: Process fluids must have a surface tension of <32 mN/m (dyne/cm) to properly wet the filter and to achieve
• Non-fiber releasing optimized flow rates and performance characteristics. For fluids with a surface tension ≥ 32 mN/m (dyne/cm), use
• Superior recovery of resistivity and TOC since hydrophilic PTFE (TCFH-type cartridges).
cartridges are individually flushed with pure water in
the manufacturing process S P E C I F I C AT I O N S Materials:
TCF-005 TCF-010 TCF-020 TCF-050 TCF-100 TCF-020L End cap Polypropylene
S P E C I F I C AT I O N S Materials: Pore size 0.05 µm 0.10 µm 0.20 µm 0.50 µm 1.00 µm 0.20 µm Support media Polypropylene
TCS-E020 TCS-E045 TCS-E045S TCS-E-020/045 TCS-E-045S Filtration area per single length 9200 cm2 9200 cm2 7000 cm2 7000 cm2 7000 cm2 16,400 cm2 Membrane PTFE
Pore size 0.20 µm 0.45 µm 0.45 µm End cap Polypropylene Polypropylene Max. differential pressure (25°C) 0.39 MPa (57 psi) 0.25 MPa (36 psi) Core tube Polypropylene
Filtration area (with 250 mm) 6700 cm2 8800 cm2 Support media Polypropylene Polypropylene Max. operating temperature 80°C (176°F) 40°C (104°F) Outer sleeve Polypropylene
Max. differential pressure (25°C) 0.39 MPa [57 psi] Prefilter membrane Polytethersulfone (PES) -
Max. operating temperature 80°C (176°F) Final membrane Polytethersulfone (PES) Polyethersulfone (PES) O R D E R I N G I N F O R M AT I O N
Core tube Polypropylene Polypropylene
Outer sleeve Polypropylene Polypropylene TCF - 0 2 0 L - *1 3 *2
TCF - - 1
O R D E R I N G I N F O R M AT I O N

TCS-E - - 1
Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring
(µm) Code (mm) Code Code Polymer Code
0.05 005 250 (single) S F R EPR E (standard)
Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring 0.10 010 500 (double) D N K EPDM D
(µm) Code (mm) Code Code Polymer Code 0.20 020 750 (triple) T M P Chloroprene N
0.20 020 250 (single) S F R EPR E (standard) 0.50 050 1000 (quad) Q H J NBR B
0.45 045 500 (double) D M P EPDM D 1.00 100 *1 Available with length codes Note: Codes H, J, K, and N are Silicone S
0.45 045S 750 (triple) T Chloroprene N S, D, and T. autoclavable at 121ºC, 30 min, or can FPM V
be steam sterilized at 126ºC for 30 min.
1000 (quad) Q NBR B PTFE H (Gasket only)
*2 Available with end fixture codes
Silicone S F, M, R, and P. FEP F (O-ring only)
Encapsulated
FPM V

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
25
TCF-005 TCF-005
[3.6] TCS-E020 TCF-010
Differential Pressure (kPa [psi])

0.8
100
[0.11]
Differential Pressure (kPa [psi])

[14.5] 1.0

Differential Pressure (kPa [psi])

Differential Pressure (kPa [psi])


[0.14]
20 TCS-E020
TCF-020
[2.9]
0.6 80
[11.6] 0.8
[0.09] [0.12]
15
[2.2] TCF-050
TCS-E045 60 TCF-010
0.6
0.4 [8.7]
[0.09] TCF-020L
[0.06] TCS-E045
10
TCF-100
[1.4]
TCS-E045S 40 0.4
TCS-E045S
[5.8] TCF-020 [0.06]
TCF-050
0.2
5 [0.03] TCF-020L
[0.7] 20 TCF-100 0.2
[2.9] [0.03]

0 10 20 30 40 0 100 200 300 400 500


0 10 20 30 40 0 100 200 300 400 500
Flow Rate (L/min/250 mm length) Flow Rate (L/min/250 mm length) Flow Rate (L/min/250 mm length) Flow Rate (L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
60 61
C ARTRI DG E S C ARTRI DG E S

Hydrophilic PTFE (TCFH) Coated Cellulose Acetate (TCY)


• Unsupported PTFE membrane has been treated to A P P L I C AT I O N S • Dual layer of coated cellulose acetate membrane A P P L I C AT I O N S
render the matrix hydrophilic • Strong acid and strong alkali solutions • Low protein binding • Use as a prefilter to a final membrane cartridge
• Polypropylene support is non-fiber releasing • Photo resists • Excellent dirt holding characteristics, superior particle • Filter protein-containing solutions for the food,
• Chemically aggressive liquids with a surface retention cosmetic and pharmaceutical industries
tension ≥32 mN/m (dyne/cm) • Excellent water and air flow rates • Purify process waters
Note: This cartridge is not autoclavable. • Non-fiber releasing

S P E C I F I C AT I O N S Materials: S P E C I F I C AT I O N S Materials:
TCY-ND, -LD, -HD End cap Polypropylene
TCFH-010 TCFH-020 TCFH-050 TCFH-100 TCFH-020L End cap Polypropylene
Filtration area per single length 5500 cm2 Support media Polypropylene
Pore size 0.10 µm 0.20 µm 0.50 µm 1.00 µm 0.20 µm Support media Polypropylene
Max. differential pressure (25°C) 0.49 MPa (71 psi) Prefilter membrane Coated cellulose acetate
Filtration area per single length 9800 cm2 21,600 cm2 Membrane Hydrophilic PTFE
Max. operating temperature 80°C (176°F) Final membrane Coated cellulose acetate
Max.differential pressure (25°C) 0.39 MPa (57 psi) 0.39 MPa (57 psi) Core tube Polypropylene
Max. operating temperature 80°C (176°F) 60°C (140°F) Outer sleeve Polypropylene Core tube Polypropylene
Outer sleeve Polypropylene

O R D E R I N G I N F O R M AT I O N Retention Particle Size


Characteristic 0.21µm 0.3 µm 0.48 µm 0.65 µm 0.8 µm 1.0 µm 2.0 µm
TCFH - - 1 Code % Particle Retention
TCY-ND 99.9 99.9 99.9 >99.9
TCY-LD 99 99.9 99.9 >99.9
TCY-HD 99 99.9 99.9 99.9 >99.9
Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring Test Criteria: Single length (250 mm) cartridge, flow rate 10 L/min.
(µm) Code (mm) Code Code Polymer Code
0.10 010 250 (single) S F R EPR E (standard) O R D E R I N G I N F O R M AT I O N
0.20 020/020L 500 (double) D N EPDM D
0.50 050 750 (triple) T M P Chloroprene N
TCY - - 1
1.00 100 1000 (quad) Q NBR B
Silicone S
FPM V
PTFE H (Gasket only) Retention Length Length End Fixture Gasket/O-ring Gasket/O-ring
FEP F (O-ring only) Characteristic (mm) Code Code Polymer Code
Encapsulated
Code
ND 250 (single) S F R EPR E (standard)
T Y P I C A L W AT E R F L O W R AT E
LD 500 (double) D N K EPDM D
HD 750 (triple) T M P Chloroprene N
50
[7.2]
1000 (quad) Q H J NBR B
Note: Codes H, J, K, and N are Silicone S
Differential Pressure (kPa [psi])

autoclavable at 121ºC, 30 min. FPM V


40
[5.8]

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
TCFH-010 TCY-ND
30
2.0
[4.3] TCFH-020
[0.29]

Differential Pressure (kPa [psi])


TCFH-020L 50
TCY-ND

Differential Pressure (kPa [psi])


[7.2]

20
[2.9] 40 1.5
[5.8] [0.22]

TCFH-050

10 30
[1.4] [4.3] 1.0
TCY-LD
TCFH-100
[0.14]

20 TCY-LD
[2.9]
0 10 20 30 40 0.5
TCY-HD
[0.07]
10 TCY-HD
Flow Rate (L/min/250 mm length) [1.4]
Conditions: Pipe dia. 3/4 in., Water temp. 20°C

0 100 200 300 400 500


0 10 20 30 40

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)


Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
60 61
C ARTRI DG E S C ARTRI DG E S

Hydrophilic PTFE (TCFH) Coated Cellulose Acetate (TCY)


• Unsupported PTFE membrane has been treated to A P P L I C AT I O N S • Dual layer of coated cellulose acetate membrane A P P L I C AT I O N S
render the matrix hydrophilic • Strong acid and strong alkali solutions • Low protein binding • Use as a prefilter to a final membrane cartridge
• Polypropylene support is non-fiber releasing • Photo resists • Excellent dirt holding characteristics, superior particle • Filter protein-containing solutions for the food,
• Chemically aggressive liquids with a surface retention cosmetic and pharmaceutical industries
tension ≥32 mN/m (dyne/cm) • Excellent water and air flow rates • Purify process waters
Note: This cartridge is not autoclavable. • Non-fiber releasing

S P E C I F I C AT I O N S Materials: S P E C I F I C AT I O N S Materials:
TCY-ND, -LD, -HD End cap Polypropylene
TCFH-010 TCFH-020 TCFH-050 TCFH-100 TCFH-020L End cap Polypropylene
Filtration area per single length 5500 cm2 Support media Polypropylene
Pore size 0.10 µm 0.20 µm 0.50 µm 1.00 µm 0.20 µm Support media Polypropylene
Max. differential pressure (25°C) 0.49 MPa (71 psi) Prefilter membrane Coated cellulose acetate
Filtration area per single length 9800 cm2 21,600 cm2 Membrane Hydrophilic PTFE
Max. operating temperature 80°C (176°F) Final membrane Coated cellulose acetate
Max.differential pressure (25°C) 0.39 MPa (57 psi) 0.39 MPa (57 psi) Core tube Polypropylene
Max. operating temperature 80°C (176°F) 60°C (140°F) Outer sleeve Polypropylene Core tube Polypropylene
Outer sleeve Polypropylene

O R D E R I N G I N F O R M AT I O N Retention Particle Size


Characteristic 0.21µm 0.3 µm 0.48 µm 0.65 µm 0.8 µm 1.0 µm 2.0 µm
TCFH - - 1 Code % Particle Retention
TCY-ND 99.9 99.9 99.9 >99.9
TCY-LD 99 99.9 99.9 >99.9
TCY-HD 99 99.9 99.9 99.9 >99.9
Pore Size Pore Size Length Length End Fixture Gasket/O-ring Gasket/O-ring Test Criteria: Single length (250 mm) cartridge, flow rate 10 L/min.
(µm) Code (mm) Code Code Polymer Code
0.10 010 250 (single) S F R EPR E (standard) O R D E R I N G I N F O R M AT I O N
0.20 020/020L 500 (double) D N EPDM D
0.50 050 750 (triple) T M P Chloroprene N
TCY - - 1
1.00 100 1000 (quad) Q NBR B
Silicone S
FPM V
PTFE H (Gasket only) Retention Length Length End Fixture Gasket/O-ring Gasket/O-ring
FEP F (O-ring only) Characteristic (mm) Code Code Polymer Code
Encapsulated
Code
ND 250 (single) S F R EPR E (standard)
T Y P I C A L W AT E R F L O W R AT E
LD 500 (double) D N K EPDM D
HD 750 (triple) T M P Chloroprene N
50
[7.2]
1000 (quad) Q H J NBR B
Note: Codes H, J, K, and N are Silicone S
Differential Pressure (kPa [psi])

autoclavable at 121ºC, 30 min. FPM V


40
[5.8]

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
TCFH-010 TCY-ND
30
2.0
[4.3] TCFH-020
[0.29]

Differential Pressure (kPa [psi])


TCFH-020L 50
TCY-ND

Differential Pressure (kPa [psi])


[7.2]

20
[2.9] 40 1.5
[5.8] [0.22]

TCFH-050

10 30
[1.4] [4.3] 1.0
TCY-LD
TCFH-100
[0.14]

20 TCY-LD
[2.9]
0 10 20 30 40 0.5
TCY-HD
[0.07]
10 TCY-HD
Flow Rate (L/min/250 mm length) [1.4]
Conditions: Pipe dia. 3/4 in., Water temp. 20°C

0 100 200 300 400 500


0 10 20 30 40

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)


Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
62 63
C ARTRI DG E S C ARTRI DG E S

Single Layer Coated Cellulose Acetate (TCYE) Polypropylene (TCP)


• High efficiency single layer of coated cellulose acetate A P P L I C AT I O N S • Multiple layers of nonwoven polypropylene maximize A P P L I C AT I O N S
• Economical • Filter process waters filtration efficiency • Filter process waters
• Excellent particle retention • Filter protein-containing solutions for the food, • Maximal throughput volumes and retention ratings • Filter protein-containing solutions for the food,
• Low protein binding, non-fiber releasing cosmetic and pharmaceutical industries • Thermally bonded to prevent fiber slough-off, minimize cosmetic and pharmaceutical industries
• Excellent water and air flow rates extractables
• Supported both upstream and downstream (TCP-HX, FX only)
S P E C I F I C AT I O N S Materials: Materials:
TCYE-NS, -LS, -HS, -BS End cap Polypropylene S P E C I F I C AT I O N S End cap Polypropylene
Filtration area per single length 6200 cm2 Support media Polypropylene TCP-LX TCP-JX TCP-HX TCP-FX TCP-02AM Support media Polypropylene
Max. differential pressure (25°C) 0.49 MPa (71 psi) Membrane Coated cellulose acetate Filtration area per single length 3300 cm2 4500 cm2 4200 cm2 5100 cm2 2900 cm2 Membrane Polypropylene
Max. operating temperature 80°C (176°F) Core tube Polypropylene Max. differential pressure (25°C) 0.49 MPa (71 psi) Core tube Polypropylene
Outer sleeve Polypropylene Max. operating temperature 80°C (176°F) Outer sleeve Polypropylene

Retention Particle Size % Retention


Retention Particle Size
Characteristic 0.2 µm 0.48 µm 0.65 µm 0.8 µm 1.0 µm 2.0 µm 3.0 µm (0.3 µm
Characteristic 0.21µm 0.3 µm 0.48 µm 0.65 µm 0.8 µm 1.0 µm 2.0 µm 3.0 µm 5.0 µm 10 µm
Code % Particle Retention DOP)
Code % Particle Retention
TCP-LX 45 90 98 >99 99.9999
TCYE-NS 99 99.9 99.9 >99.9
TCP-JX 60 80 94 >99 99.999
TCYE-LS 98 99 99 >99.9
TCP-HX 70 93 >99 99.99
TCYE-HS 96 99 99 99 >99.9
TCP-FX 30 60 95 >99 99.84
TCYE-BS 98 99.9 99.9 >99.9
TCP-02AM 43 77 >99 -
Test Criteria: Single length (250 mm) cartridge, flow rate 10 L/min.
Test Criteria: Single length (250 mm) cartridge, flow rate 10 L/min.
O R D E R I N G I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
TCYE - - 1
TCP - - 1

Retention Length Length End Fixture Gasket/O-ring Gasket/O-ring


Characteristic (mm) Code Code Polymer Code Retention Length Length End Fixture Gasket/O-ring Gasket/O-ring
Code Characteristic (mm) Code Code Polymer Code
Code
NS 250 (single) S F R EPR E (standard)
LX 250 (single) S F R EPR E (standard)
LS 500 (double) D N K EPDM D
JX 500 (double) D N K EPDM D
HS 750 (triple) T M P Chloroprene N
HX 750 (triple) T M P Chloroprene N
BS 1000 (quad) Q H J NBR B
FX 1000 (quad) Q H J NBR B
Note: Codes H, J, K, and N are Silicone S
autoclavable at 121ºC, 30 min. 02AM Silicone S
FPM V Note: Codes H, J, K, and N are
autoclavable at 121ºC, 30 min. FPM V
PTFE H (Gasket only)
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E FEP F (O-ring only)
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E Encapsulated
TCYE-NS
25 1.0
[3.6] [0.14] TCP-LX
Differential Pressure (kPa [psi])

TCP-LX TCP-JX
Differential Pressure (kPa [psi])

50 1.0

Differential Pressure (kPa [psi])

Differential Pressure (kPa [psi])


[7.2] [0.14]
20 0.8
[2.9] [0.11] TCYE-NS
40 0.8
TCYE-LS
[5.8] [0.12] TCP-02AM

15 0.6
[2.2] [0.09] TCP-JX
TCYE-HS TCYE-LS 30 0.6
[4.3] [0.09]
10 0.4 TCP-HX
[1.4] [0.06]
20 0.4
TCYE-BS TCP-02AM
TCYE-HS [2.9] [0.06]
TCP-HX
5 0.2 TCP-FX
[0.7] [0.03] 10 TCP-FX 0.2
TCYE-BS [1.4] [0.03]

0 10 20 30 40 0 100 200 300 400 500 0 100 200 300 400 500
0 10 20 30 40

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length) Flow Rate (L/min/250 mm length)
Flow Rate (L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
62 63
C ARTRI DG E S C ARTRI DG E S

Single Layer Coated Cellulose Acetate (TCYE) Polypropylene (TCP)


• High efficiency single layer of coated cellulose acetate A P P L I C AT I O N S • Multiple layers of nonwoven polypropylene maximize A P P L I C AT I O N S
• Economical • Filter process waters filtration efficiency • Filter process waters
• Excellent particle retention • Filter protein-containing solutions for the food, • Maximal throughput volumes and retention ratings • Filter protein-containing solutions for the food,
• Low protein binding, non-fiber releasing cosmetic and pharmaceutical industries • Thermally bonded to prevent fiber slough-off, minimize cosmetic and pharmaceutical industries
• Excellent water and air flow rates extractables
• Supported both upstream and downstream (TCP-HX, FX only)
S P E C I F I C AT I O N S Materials: Materials:
TCYE-NS, -LS, -HS, -BS End cap Polypropylene S P E C I F I C AT I O N S End cap Polypropylene
Filtration area per single length 6200 cm2 Support media Polypropylene TCP-LX TCP-JX TCP-HX TCP-FX TCP-02AM Support media Polypropylene
Max. differential pressure (25°C) 0.49 MPa (71 psi) Membrane Coated cellulose acetate Filtration area per single length 3300 cm2 4500 cm2 4200 cm2 5100 cm2 2900 cm2 Membrane Polypropylene
Max. operating temperature 80°C (176°F) Core tube Polypropylene Max. differential pressure (25°C) 0.49 MPa (71 psi) Core tube Polypropylene
Outer sleeve Polypropylene Max. operating temperature 80°C (176°F) Outer sleeve Polypropylene

Retention Particle Size % Retention


Retention Particle Size
Characteristic 0.2 µm 0.48 µm 0.65 µm 0.8 µm 1.0 µm 2.0 µm 3.0 µm (0.3 µm
Characteristic 0.21µm 0.3 µm 0.48 µm 0.65 µm 0.8 µm 1.0 µm 2.0 µm 3.0 µm 5.0 µm 10 µm
Code % Particle Retention DOP)
Code % Particle Retention
TCP-LX 45 90 98 >99 99.9999
TCYE-NS 99 99.9 99.9 >99.9
TCP-JX 60 80 94 >99 99.999
TCYE-LS 98 99 99 >99.9
TCP-HX 70 93 >99 99.99
TCYE-HS 96 99 99 99 >99.9
TCP-FX 30 60 95 >99 99.84
TCYE-BS 98 99.9 99.9 >99.9
TCP-02AM 43 77 >99 -
Test Criteria: Single length (250 mm) cartridge, flow rate 10 L/min.
Test Criteria: Single length (250 mm) cartridge, flow rate 10 L/min.
O R D E R I N G I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
TCYE - - 1
TCP - - 1

Retention Length Length End Fixture Gasket/O-ring Gasket/O-ring


Characteristic (mm) Code Code Polymer Code Retention Length Length End Fixture Gasket/O-ring Gasket/O-ring
Code Characteristic (mm) Code Code Polymer Code
Code
NS 250 (single) S F R EPR E (standard)
LX 250 (single) S F R EPR E (standard)
LS 500 (double) D N K EPDM D
JX 500 (double) D N K EPDM D
HS 750 (triple) T M P Chloroprene N
HX 750 (triple) T M P Chloroprene N
BS 1000 (quad) Q H J NBR B
FX 1000 (quad) Q H J NBR B
Note: Codes H, J, K, and N are Silicone S
autoclavable at 121ºC, 30 min. 02AM Silicone S
FPM V Note: Codes H, J, K, and N are
autoclavable at 121ºC, 30 min. FPM V
PTFE H (Gasket only)
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E FEP F (O-ring only)
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E Encapsulated
TCYE-NS
25 1.0
[3.6] [0.14] TCP-LX
Differential Pressure (kPa [psi])

TCP-LX TCP-JX
Differential Pressure (kPa [psi])

50 1.0

Differential Pressure (kPa [psi])

Differential Pressure (kPa [psi])


[7.2] [0.14]
20 0.8
[2.9] [0.11] TCYE-NS
40 0.8
TCYE-LS
[5.8] [0.12] TCP-02AM

15 0.6
[2.2] [0.09] TCP-JX
TCYE-HS TCYE-LS 30 0.6
[4.3] [0.09]
10 0.4 TCP-HX
[1.4] [0.06]
20 0.4
TCYE-BS TCP-02AM
TCYE-HS [2.9] [0.06]
TCP-HX
5 0.2 TCP-FX
[0.7] [0.03] 10 TCP-FX 0.2
TCYE-BS [1.4] [0.03]

0 10 20 30 40 0 100 200 300 400 500 0 100 200 300 400 500
0 10 20 30 40

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length) Flow Rate (L/min/250 mm length)
Flow Rate (L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
64 65
C ARTRI DG E S C ARTRI DG E S
Multigrade Polypropylene (TCPD)
Single Layer Polypropylene (TCP/TCPE) • Spirally wound multigrade all-polypropylene A P P L I C AT I O N S
construction • Ideal for viscous fluids and fluids that have a
• All-polypropylene construction, medium is single layer A P P L I C AT I O N S • Increasing depth retention gradient: as fluid flows heterogeneous particle population
of thermally bonded polypropylene • Use as a prefilter in series upstream of a final Prefilter or clarifying filter
through the cartridge, retention efficiency increases •
• Pore size range 1 – 30 µm membrane to clarify solutions Filtration of pure or rinse waters, magnetized paint
• Maximal chemical compatibility •
• TCP – Upstream and downstream support • Applications that require chemical resistance and coatings, synthetic resins, high viscosity resins, plating
– Larger effective filtration area chemical cleanliness solutions, etching solutions and strong alkali solutions
• TCPE – Thicker grade of polypropylene is stronger
and does not require support S P E C I F I C AT I O N S Materials:
– Less effective filtration area TCPD-01A, -02A, -03A, -05A, -1, -3, -7, -10, -30 End cap Polypropylene
Max. differential pressure (25°C) 0.49 MPa (71 psi) Support media Polypropylene net
S P E C I F I C AT I O N S Max. operating temperature 80°C (176°F) Filter Polypropylene
TCP-1 TCP-3 TCP-7 TCP-10 TCP-30 TCPE-3 TCPE-10 TCPE-30 Core tube Polypropylene
Nominal pore size 1 µm 3 µm 7 µm 10 µm 30 µm 3 µm 10 µm 30 µm
Retention Particle Size
Filtration area per single length 4200 cm2 5600 cm2 4200 cm2 5000 cm2 6200 cm2 3700 cm2
Characteristic 0.6 µm 1.0 µm 2 µm 3 µm 5 µm 10 µm 20 µm 30 µm 40 µm 70 µm
Max. differential pressure (25°C) 0.49 MPa (71 psi)
Code % Particle Retention
Max. operating temperature 80°C (176°F)
TCPD-01A 90 >99.9
TCPD-02A >99 >99.9
Materials: TCPD-03A 95 >99 >99.9
End cap Polypropylene TCPD-05A 95 >99 >99.9
O R D E R I N G I N F O R M AT I O N Support Media (TCP) Polypropylene TCPD-1 90 95 >99
Membrane Polypropylene TCPD-3 70 90 >99
TCP - - 1 Core tube Polypropylene TCPD-7 40 80 >99
Outer sleeve Polypropylene TCPD-10 60 90 95 >99
TCPE - - 1 TCPD-30 60 90 95 >99

O R D E R I N G I N F O R M AT I O N
Nominal Nominal Length Length End Fixture Gasket/O-ring Gasket/O-ring
TCPD - - 1
Pore Size Pore Size (mm) Code Code Polymer Code
Code (TCP) Code (TCPE)
1 - 250 (single) S F R EPR E (standard)
3 3 500 (double) D N K EPDM D Nominal Length Length End Fixture Gasket/O-ring Gasket/O-ring
7 - 750 (triple) T M P Chloroprene N Pore Size (mm) Code Code Polymer Code
10 10 1000 (quad) Q H J NBR B Code
30 30 Note: Codes H, J, K, and N are Silicone S 01A 1 250 (single) S F R EPR E (standard)
autoclavable at 121ºC, 30 min
FPM V 02A 3 500 (double) D N K EPDM D
PTFE H (Gasket only) 03A 7 750 (triple) T M P Chloroprene N
FEP F (O-ring only) 05A 10 1000 (quad) Q H J NBR B
Encapsulated
30 Note: Codes H, J, K, and N are Silicone S
autoclavable at 121ºC, 30 min.
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E FPM V
PTFE H (Gasket only)
TCP-1, TCPE-3 TCPE-3
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E FEP F (O-ring only)
10
Differential Pressure (kPa [psi])

TCPD-01A TCPD-02A TCPD-02A Encapsulated


Differential Pressure (kPa [psi])

[1.4] TCPD-03A TCPD-01A 03A TCPD-05A


0.3
[0.043] 100

Differential Pressure (kPa [psi])


TCP-1, TCPE-10 2.0

Differential Pressure (kPa [psi])


8 [14.5]
[0.29]
[1.2]
TCPD-05A
TCP-3, 7, 10, 30 80
TCPE-10, 30 0.2 [11.6] 1.5
6
[0.029] [0.22]
[0.9] TCP-3, 7, 10, 30 TCPD-1

TCPE-30 60
[8.7]
4 1.0
[0.6] [0.14] TCPD-3
0.1
[0.014] 40
TCPD-1
[5.8]
2
[0.3] TCPD-3
0.5
[0.07] TCPD-7
20
TCPD-10
[2.9] TCPD-30
TCPD-10
0 10 20 30 40 0 100 200 300 400 500 TCPD-30

0 100 200 300 400 500


0 10 20 30 40
Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
64 65
C ARTRI DG E S C ARTRI DG E S
Multigrade Polypropylene (TCPD)
Single Layer Polypropylene (TCP/TCPE) • Spirally wound multigrade all-polypropylene A P P L I C AT I O N S
construction • Ideal for viscous fluids and fluids that have a
• All-polypropylene construction, medium is single layer A P P L I C AT I O N S • Increasing depth retention gradient: as fluid flows heterogeneous particle population
of thermally bonded polypropylene • Use as a prefilter in series upstream of a final Prefilter or clarifying filter
through the cartridge, retention efficiency increases •
• Pore size range 1 – 30 µm membrane to clarify solutions Filtration of pure or rinse waters, magnetized paint
• Maximal chemical compatibility •
• TCP – Upstream and downstream support • Applications that require chemical resistance and coatings, synthetic resins, high viscosity resins, plating
– Larger effective filtration area chemical cleanliness solutions, etching solutions and strong alkali solutions
• TCPE – Thicker grade of polypropylene is stronger
and does not require support S P E C I F I C AT I O N S Materials:
– Less effective filtration area TCPD-01A, -02A, -03A, -05A, -1, -3, -7, -10, -30 End cap Polypropylene
Max. differential pressure (25°C) 0.49 MPa (71 psi) Support media Polypropylene net
S P E C I F I C AT I O N S Max. operating temperature 80°C (176°F) Filter Polypropylene
TCP-1 TCP-3 TCP-7 TCP-10 TCP-30 TCPE-3 TCPE-10 TCPE-30 Core tube Polypropylene
Nominal pore size 1 µm 3 µm 7 µm 10 µm 30 µm 3 µm 10 µm 30 µm
Retention Particle Size
Filtration area per single length 4200 cm2 5600 cm2 4200 cm2 5000 cm2 6200 cm2 3700 cm2
Characteristic 0.6 µm 1.0 µm 2 µm 3 µm 5 µm 10 µm 20 µm 30 µm 40 µm 70 µm
Max. differential pressure (25°C) 0.49 MPa (71 psi)
Code % Particle Retention
Max. operating temperature 80°C (176°F)
TCPD-01A 90 >99.9
TCPD-02A >99 >99.9
Materials: TCPD-03A 95 >99 >99.9
End cap Polypropylene TCPD-05A 95 >99 >99.9
O R D E R I N G I N F O R M AT I O N Support Media (TCP) Polypropylene TCPD-1 90 95 >99
Membrane Polypropylene TCPD-3 70 90 >99
TCP - - 1 Core tube Polypropylene TCPD-7 40 80 >99
Outer sleeve Polypropylene TCPD-10 60 90 95 >99
TCPE - - 1 TCPD-30 60 90 95 >99

O R D E R I N G I N F O R M AT I O N
Nominal Nominal Length Length End Fixture Gasket/O-ring Gasket/O-ring
TCPD - - 1
Pore Size Pore Size (mm) Code Code Polymer Code
Code (TCP) Code (TCPE)
1 - 250 (single) S F R EPR E (standard)
3 3 500 (double) D N K EPDM D Nominal Length Length End Fixture Gasket/O-ring Gasket/O-ring
7 - 750 (triple) T M P Chloroprene N Pore Size (mm) Code Code Polymer Code
10 10 1000 (quad) Q H J NBR B Code
30 30 Note: Codes H, J, K, and N are Silicone S 01A 1 250 (single) S F R EPR E (standard)
autoclavable at 121ºC, 30 min
FPM V 02A 3 500 (double) D N K EPDM D
PTFE H (Gasket only) 03A 7 750 (triple) T M P Chloroprene N
FEP F (O-ring only) 05A 10 1000 (quad) Q H J NBR B
Encapsulated
30 Note: Codes H, J, K, and N are Silicone S
autoclavable at 121ºC, 30 min.
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E FPM V
PTFE H (Gasket only)
TCP-1, TCPE-3 TCPE-3
T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E FEP F (O-ring only)
10
Differential Pressure (kPa [psi])

TCPD-01A TCPD-02A TCPD-02A Encapsulated


Differential Pressure (kPa [psi])

[1.4] TCPD-03A TCPD-01A 03A TCPD-05A


0.3
[0.043] 100

Differential Pressure (kPa [psi])


TCP-1, TCPE-10 2.0

Differential Pressure (kPa [psi])


8 [14.5]
[0.29]
[1.2]
TCPD-05A
TCP-3, 7, 10, 30 80
TCPE-10, 30 0.2 [11.6] 1.5
6
[0.029] [0.22]
[0.9] TCP-3, 7, 10, 30 TCPD-1

TCPE-30 60
[8.7]
4 1.0
[0.6] [0.14] TCPD-3
0.1
[0.014] 40
TCPD-1
[5.8]
2
[0.3] TCPD-3
0.5
[0.07] TCPD-7
20
TCPD-10
[2.9] TCPD-30
TCPD-10
0 10 20 30 40 0 100 200 300 400 500 TCPD-30

0 100 200 300 400 500


0 10 20 30 40
Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)
Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
66 67
C ARTRI DG E S C ARTRI DG E S

Epoxy Cellulose (TC) O R D E R I N G I N F O R M AT I O N


• 100% cellulose wet strengthened with epoxy resin to A P P L I C AT I O N S Stainless steel molded material
minimize fiber release • Filter high viscosity liquids such as syrups
• Available with standard polypropylene core or with stain- • Filter fuels, oils, cutting oils and resins TC - -S4C
less steel core (type 304, single length only) for high • Purify industrial and rinse waters
temperature applications
• See Glass Fiber (TCG) for smaller nominal pore sizes
Nominal Nominal Gasket/O-ring Gasket/O-ring
Note: TC-type are not autoclavable. Pore Size Pore Size Polymer Code
(µm) Code
1 1 NBR B (standard)
S P E C I F I C AT I O N S 3 3 EPR E
TC type TC- _ -S4C_ 10 10 Silicone S
Molded Material Polypropylene Stainless steel 30 30 FPM V
1 3 10 30 1 3 10 30
Nominal 1 µm 3 µm 10 µm 30 µm 1 µm 3 µm 10 µm 30 µm
pore size
Filtration area 4000 cm2 3400 cm2 T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
per single length
Max. differential 0.49 MPa (71 psi) 0.49 MPa (71 psi) TC-1

Differential Pressure (kPa [psi])


0.8

Differential Pressure (kPa [psi])


25
[0.12]
pressure (25°C) [3.6] TC-1

Max temperature 80°C (176°F) 150°C (302°F) 20


[2.9] 0.6
[0.09]
15
Materials: [2.2]
0.4
TC-3 [0.06]
End cap Polypropylene 10
[1.4] TC-10, 30
Stainless steel (seal material: silicone) 0.2
TC-3, 10, 30

5
Filter Epoxy Cellulose [0.7]
[0.03]

Core tube Polypropylene or


stainless steel 0 10 20 30 40 0 100 200 300 400 500

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)


Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
O R D E R I N G I N F O R M AT I O N
Polypropylene molded material

TC - - 1

Nominal Nominal Length Length End Fixture Gasket/O-ring Gasket/O-ring


Pore Size Pore Size (mm) Code Code Polymer Code
(µm) Code
1 1 250 (single) S F R EPR E
3 3 500 (double) D N P Chloroprene N (standard)
10 10 750 (triple) T M C NBR B
30 30 1000 (quad) Q* Silicone S
FPM V

*Quad length (1000 mm) not available in end fixture Code C.

800-334-7132 w w w. a d v a n t e c m f s . c o m
66 67
C ARTRI DG E S C ARTRI DG E S

Epoxy Cellulose (TC) O R D E R I N G I N F O R M AT I O N


• 100% cellulose wet strengthened with epoxy resin to A P P L I C AT I O N S Stainless steel molded material
minimize fiber release • Filter high viscosity liquids such as syrups
• Available with standard polypropylene core or with stain- • Filter fuels, oils, cutting oils and resins TC - -S4C
less steel core (type 304, single length only) for high • Purify industrial and rinse waters
temperature applications
• See Glass Fiber (TCG) for smaller nominal pore sizes
Nominal Nominal Gasket/O-ring Gasket/O-ring
Note: TC-type are not autoclavable. Pore Size Pore Size Polymer Code
(µm) Code
1 1 NBR B (standard)
S P E C I F I C AT I O N S 3 3 EPR E
TC type TC- _ -S4C_ 10 10 Silicone S
Molded Material Polypropylene Stainless steel 30 30 FPM V
1 3 10 30 1 3 10 30
Nominal 1 µm 3 µm 10 µm 30 µm 1 µm 3 µm 10 µm 30 µm
pore size
Filtration area 4000 cm2 3400 cm2 T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
per single length
Max. differential 0.49 MPa (71 psi) 0.49 MPa (71 psi) TC-1

Differential Pressure (kPa [psi])


0.8

Differential Pressure (kPa [psi])


25
[0.12]
pressure (25°C) [3.6] TC-1

Max temperature 80°C (176°F) 150°C (302°F) 20


[2.9] 0.6
[0.09]
15
Materials: [2.2]
0.4
TC-3 [0.06]
End cap Polypropylene 10
[1.4] TC-10, 30
Stainless steel (seal material: silicone) 0.2
TC-3, 10, 30

5
Filter Epoxy Cellulose [0.7]
[0.03]

Core tube Polypropylene or


stainless steel 0 10 20 30 40 0 100 200 300 400 500

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)


Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C
O R D E R I N G I N F O R M AT I O N
Polypropylene molded material

TC - - 1

Nominal Nominal Length Length End Fixture Gasket/O-ring Gasket/O-ring


Pore Size Pore Size (mm) Code Code Polymer Code
(µm) Code
1 1 250 (single) S F R EPR E
3 3 500 (double) D N P Chloroprene N (standard)
10 10 750 (triple) T M C NBR B
30 30 1000 (quad) Q* Silicone S
FPM V

*Quad length (1000 mm) not available in end fixture Code C.

800-334-7132 w w w. a d v a n t e c m f s . c o m
68 69
C ARTRI DG E S C ARTRI DG E S

Glass Fiber (TCG) All Polypropylene (OH)


• Upstream polypropylene followed by a glass fiber layer A P P L I C AT I O N S • All-polypropylene construction: melt blown polypropylene A P P L I C AT I O N S
that is wet strengthened with acrylic resin • Filter high viscosity liquids such as syrups filaments are spun into a gradient density media, maximiz- • Prefilter upstream of a final pleated cartridge
• For larger pore size retention see Epoxy Cellulose (TC) • Filter fuels, oils, cutting oils and resins ing particle retention • Moderate differential pressures and temperatures
• Purify industrial and rinse waters • Excellent flow rates
Note: TCG-type cartridges are not autoclavable. • Double open end: Compression seal eliminates the need
for O-rings or gaskets
S P E C I F I C AT I O N S
TCG-045 TCG-1 S P E C I F I C AT I O N S P E R F O R M A N C E D ATA
Nominal pore size 0.45 µm 1 µm OH WATER FLOW RATE 1
Filtration area per single length 3300 cm2 Nominal pore size 1 – 75 µm
kPa psi
Max. differential pressure (25°C) 0.49 MPa (71 psi) Max. operating pressure (25°C) 0.11 MPa (15 psi) 1. OHO010
Max. operating temperature 80°C (176°F) Max. temperature 60°C (140°F) 15 1 2
2. OHO030
2.0 3
3. OHO050
Materials: 4. OHO100
O R D E R I N G I N F O R M AT I O N 5. OHO200
End cap Polypropylene 4

Differential Pressure
6. OHO300
Upstream support Polypropylene 1.5

Filter Glass Fiber


OH O - - C 10 7. OHO500 5

8. OHO750
Downstream support Polypropylene 6

Core tube Polypropylene 1.0


Outer sleeve Polypropylene Nominal Pore Nominal Pore Length Length
7

Size (µm) Size Code (inches) Code 5


8

1 010 10 10
O R D E R I N G I N F O R M AT I O N 0.5
3 030 20 20
5 050 30 30
TCG - - 1 10 100 40 40
20 200 0
0 2 6 8 10
4
30 300 GPM
50 500 0 10 20 30 40
Nominal Pore Nominal Pore Length Length End Fixture Gasket/O-ring Gasket/O-ring 75 750 LPM

Size (µm) Size Code (mm) Code Code Polymer Code 1. Conditions: clean water at 25˚C; data are for 10-inch cartridges
0.45 045 250 (single) S F R EPR E
1 1 500 (double) D N EPDM D
750 (triple) T M P Chloroprene N (standard)
1000 (quad) Q NBR B
Silicone S
FPM V

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
TCG 045, 1 TCG 045, 1
Differential Pressure (kPa [psi])

25 0.8
Differential Pressure (kPa [psi])

[3.6] [0.12]

20
[2.9] 0.6
[0.09]
15
[2.2]
0.4
[0.06]
10
[1.4]

0.2
5 [0.03]
[0.7]

0 10 20 30 40 0 100 200 300 400 500

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)


Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
68 69
C ARTRI DG E S C ARTRI DG E S

Glass Fiber (TCG) All Polypropylene (OH)


• Upstream polypropylene followed by a glass fiber layer A P P L I C AT I O N S • All-polypropylene construction: melt blown polypropylene A P P L I C AT I O N S
that is wet strengthened with acrylic resin • Filter high viscosity liquids such as syrups filaments are spun into a gradient density media, maximiz- • Prefilter upstream of a final pleated cartridge
• For larger pore size retention see Epoxy Cellulose (TC) • Filter fuels, oils, cutting oils and resins ing particle retention • Moderate differential pressures and temperatures
• Purify industrial and rinse waters • Excellent flow rates
Note: TCG-type cartridges are not autoclavable. • Double open end: Compression seal eliminates the need
for O-rings or gaskets
S P E C I F I C AT I O N S
TCG-045 TCG-1 S P E C I F I C AT I O N S P E R F O R M A N C E D ATA
Nominal pore size 0.45 µm 1 µm OH WATER FLOW RATE 1
Filtration area per single length 3300 cm2 Nominal pore size 1 – 75 µm
kPa psi
Max. differential pressure (25°C) 0.49 MPa (71 psi) Max. operating pressure (25°C) 0.11 MPa (15 psi) 1. OHO010
Max. operating temperature 80°C (176°F) Max. temperature 60°C (140°F) 15 1 2
2. OHO030
2.0 3
3. OHO050
Materials: 4. OHO100
O R D E R I N G I N F O R M AT I O N 5. OHO200
End cap Polypropylene 4

Differential Pressure
6. OHO300
Upstream support Polypropylene 1.5

Filter Glass Fiber


OH O - - C 10 7. OHO500 5

8. OHO750
Downstream support Polypropylene 6

Core tube Polypropylene 1.0


Outer sleeve Polypropylene Nominal Pore Nominal Pore Length Length
7

Size (µm) Size Code (inches) Code 5


8

1 010 10 10
O R D E R I N G I N F O R M AT I O N 0.5
3 030 20 20
5 050 30 30
TCG - - 1 10 100 40 40
20 200 0
0 2 6 8 10
4
30 300 GPM
50 500 0 10 20 30 40
Nominal Pore Nominal Pore Length Length End Fixture Gasket/O-ring Gasket/O-ring 75 750 LPM

Size (µm) Size Code (mm) Code Code Polymer Code 1. Conditions: clean water at 25˚C; data are for 10-inch cartridges
0.45 045 250 (single) S F R EPR E
1 1 500 (double) D N EPDM D
750 (triple) T M P Chloroprene N (standard)
1000 (quad) Q NBR B
Silicone S
FPM V

T Y P I C A L W AT E R F L O W R AT E T Y P I C A L A I R F L O W R AT E
TCG 045, 1 TCG 045, 1
Differential Pressure (kPa [psi])

25 0.8
Differential Pressure (kPa [psi])

[3.6] [0.12]

20
[2.9] 0.6
[0.09]
15
[2.2]
0.4
[0.06]
10
[1.4]

0.2
5 [0.03]
[0.7]

0 10 20 30 40 0 100 200 300 400 500

Flow Rate (L/min/250 mm length) Flow Rate (N L/min/250 mm length)


Conditions: Pipe dia. 3/4 in., Water temp. 20°C Conditions: Pipe dia. 3/4 in., Air 0.49 MPs, 25°C

800-334-7132 w w w. a d v a n t e c m f s . c o m
70 71
C ARTRI DG E S C ARTRI DG E H OU S I NG S

String Wound (W) Stainless Steel Cartridge Housing – 1TS Type


• Manufactured using “string” of selected materials wound A P P L I C AT I O N S • Stainless steel housing for single cartridge filter, consisting
around a core tube • Coarse filtration upstream of a final pleated filter of body and head with center post
• Core tubes available in polypropylene and three grades • Filtration of industrial water • Easily perform cartridge filter replacement by loosening
of steel • Clarification of process fluids the cap nut and removing the housing head
• Continuously wound – no joints that would restrict flow • Choose from 3/4" PT or 1" PT inlet/outlet
or allow by-pass • Designed for use with end fixture codes C and F
• Double-open end – compression seal eliminates the need • Mounting accessories available
for O-rings or gaskets
• Selection of materials allows a wide range of chemical S P E C I F I C AT I O N S
and temperature tolerances Model 1TS 1TS-2 1TS-B 1TS-2B
Cartridge Capacity 250 mm x 1 500 mm x 1 250 mm x 1 500 mm x 1
S P E C I F I C AT I O N S Cartridge Compatibility End fixture codes: C and F
All W cartridges Inlet/Outlet 3/4" PT 1" PT
Nominal pore size 0.5 – 200 µm Dimensions Height 366 619 369 622
Max. inlet pressure (25°C) 0.11 MPa (15 psi) (mm) Diameter 121 121 123 123
Max. Operation Pressure 0.69 MPa (100 psi)
Composition Head: SCS14
O R D E R I N G I N F O R M AT I O N Body: SUS316 Gasket: FPM, PTFE
Weight (kg) 2.0 4.0 2.4 4.4
W- -C O Note: Use thread-sealing tape on tapered inlet and outlet.
1TS, 1TS-2

O R D E R I N G I N F O R M AT I O N
String String Composition Core Composition Core Composition Nominal Pore Nominal Pore Length Length Model 1TS 1TS-2 1TS-B 1TS-2B Sealing Nut
Composition Code Code Size (µm) Size Code (inches) Code
Catalog No. 26804010 26804020 26804040 26804030
Bleached cotton, B Tin plated steel D 0.5 005 5 B Vent Plug
industrial
Bleached cotton, C 304 stainless F 1 010 9.75 F OPTIONAL ACCESSORIES Sealing Nut Gasket
FDA
Model 1TS, 1TS-B Stand Mounting Kit Vent Plug Gasket Seal Plate
Glass fiber G 316 stainless G 3 030 10 1 OUT
Composition SUS304 Galvanized Steel
Baked glass fiber H Polypropylene P 5 050 20 2 Head O-ring
Catalog No. 28804030 28804055
Nylon N Special core Z 10 100 30 3 IN
extender, cover Washer

Polypropylene, P 15 150 40 4 Body Gasket


Spring
FDA
Fibrillated Q 20 200
polypropylene
Rayon R 25 250 Housing Body
Polyester S 30 300 Center Post
Industrial V 40 400
polypropylene 50 500
75 750
100 P10
125 P12
150 P15
200 P20

Stand Unit with Mounting Kit


Drain Plug Gasket

Drain Plug

800-334-7132 w w w. a d v a n t e c m f s . c o m
70 71
C ARTRI DG E S C ARTRI DG E H OU S I NG S

String Wound (W) Stainless Steel Cartridge Housing – 1TS Type


• Manufactured using “string” of selected materials wound A P P L I C AT I O N S • Stainless steel housing for single cartridge filter, consisting
around a core tube • Coarse filtration upstream of a final pleated filter of body and head with center post
• Core tubes available in polypropylene and three grades • Filtration of industrial water • Easily perform cartridge filter replacement by loosening
of steel • Clarification of process fluids the cap nut and removing the housing head
• Continuously wound – no joints that would restrict flow • Choose from 3/4" PT or 1" PT inlet/outlet
or allow by-pass • Designed for use with end fixture codes C and F
• Double-open end – compression seal eliminates the need • Mounting accessories available
for O-rings or gaskets
• Selection of materials allows a wide range of chemical S P E C I F I C AT I O N S
and temperature tolerances Model 1TS 1TS-2 1TS-B 1TS-2B
Cartridge Capacity 250 mm x 1 500 mm x 1 250 mm x 1 500 mm x 1
S P E C I F I C AT I O N S Cartridge Compatibility End fixture codes: C and F
All W cartridges Inlet/Outlet 3/4" PT 1" PT
Nominal pore size 0.5 – 200 µm Dimensions Height 366 619 369 622
Max. inlet pressure (25°C) 0.11 MPa (15 psi) (mm) Diameter 121 121 123 123
Max. Operation Pressure 0.69 MPa (100 psi)
Composition Head: SCS14
O R D E R I N G I N F O R M AT I O N Body: SUS316 Gasket: FPM, PTFE
Weight (kg) 2.0 4.0 2.4 4.4
W- -C O Note: Use thread-sealing tape on tapered inlet and outlet.
1TS, 1TS-2

O R D E R I N G I N F O R M AT I O N
String String Composition Core Composition Core Composition Nominal Pore Nominal Pore Length Length Model 1TS 1TS-2 1TS-B 1TS-2B Sealing Nut
Composition Code Code Size (µm) Size Code (inches) Code
Catalog No. 26804010 26804020 26804040 26804030
Bleached cotton, B Tin plated steel D 0.5 005 5 B Vent Plug
industrial
Bleached cotton, C 304 stainless F 1 010 9.75 F OPTIONAL ACCESSORIES Sealing Nut Gasket
FDA
Model 1TS, 1TS-B Stand Mounting Kit Vent Plug Gasket Seal Plate
Glass fiber G 316 stainless G 3 030 10 1 OUT
Composition SUS304 Galvanized Steel
Baked glass fiber H Polypropylene P 5 050 20 2 Head O-ring
Catalog No. 28804030 28804055
Nylon N Special core Z 10 100 30 3 IN
extender, cover Washer

Polypropylene, P 15 150 40 4 Body Gasket


Spring
FDA
Fibrillated Q 20 200
polypropylene
Rayon R 25 250 Housing Body
Polyester S 30 300 Center Post
Industrial V 40 400
polypropylene 50 500
75 750
100 P10
125 P12
150 P15
200 P20

Stand Unit with Mounting Kit


Drain Plug Gasket

Drain Plug

800-334-7132 w w w. a d v a n t e c m f s . c o m
72 73
C ARTRI DG E H OU S I NG S C ARTRI DG E H OU S I NG S

Stainless Steel Cartridge Housing – 1TM Type Sanitar y Stainless Steel Cartridge Housing – 1TVA Type
• 2-part stainless steel housing for a single cartridge filter, consisting of body • Sanitary stainless steel housing for a single cartridge filter, with sanitary
and head with clamp ferrule type inlet, outlet, and seal for easy inspection and cleaning
• Easily perform cartridge filter replacement by loosening the sealing clamp • 31/2 S-clamp wraps around body and base sections, which can be easily
and removing the housing head removed for disassembly
• Few components allows for simple maintenance, and easy operation • Designed for use with end fixture codes* C and F
• Lightweight housing can be cleaned by a washing machine • 1TVA Type is compatible with applications that require vented housings
• Designed for use with end fixture codes M, H, and L
S P E C I F I C AT I O N S
S P E C I F I C AT I O N S Model 1TVA-1S-FS 1TVA-2S-FS 1TVA-3S-FS
Model 1TM-1S-MV 1TM-2S-MV Cartridge Capacity 250 mm x 1 500 mm x 1 750 mm x 1
Cartridge Capacity 250 mm x 1 500 mm x 1 Cartridge Compatibility End fixture codes: C and F*
Cartridge Compatibility End fixture codes: M, H, L Inlet/Outlet 1S ferrule
Inlet/Outlet 1" PT Dimensions Height 408 658 908
Dimensions Height 451 704 (mm) Diameter 200
(mm) Diameter 181 Max. Operation Pressure 0.49 MPa (71 psi)
Max. Operation Pressure 0.49 MPa (71 psi) Composition Gasket: Silicon, PTFE Ball Valve: SUS316
Composition O-ring: FPM Head, Body: SU5304 Body, Base, Clamp: SUS304
Weight (kg) 1.8 2.2 Weight (kg) 3.5 5.0 6.5

Note: Use thread-sealing tape on tapered inlet and outlet. Note: Ball valve cannot be sterilized by autoclave. 1TVA-1S-FS
Use thread-sealing tape on tapered inlet and outlet.
1TM-1S-MV, 1TM-2S-MV
O R D E R I N G I N F O R M AT I O N
* Please contact us for information on sanitary housings compatible with
Model 1TM-1S-MV 1TM-2S-MV Plug
other filter cartridge end fixture codes.
Catalog No. 26805010 26805020 Plug O-ring

OUT O R D E R I N G I N F O R M AT I O N
Housing Head Model 1TVA-1S-FS 1TVA-2S-FS 1TVA-3S-FS
IN Catalog No. 26980101 26980102 26980103
Ball Valve

Body O-ring

Clamp
Housing Body

Center Post

Body Gasket
Housing Body
Housing Base

Sealing Nut Gasket


Plug O-ring 3 1/2 S Clamp
Plug Sealing Nut

800-334-7132 w w w. a d v a n t e c m f s . c o m
72 73
C ARTRI DG E H OU S I NG S C ARTRI DG E H OU S I NG S

Stainless Steel Cartridge Housing – 1TM Type Sanitar y Stainless Steel Cartridge Housing – 1TVA Type
• 2-part stainless steel housing for a single cartridge filter, consisting of body • Sanitary stainless steel housing for a single cartridge filter, with sanitary
and head with clamp ferrule type inlet, outlet, and seal for easy inspection and cleaning
• Easily perform cartridge filter replacement by loosening the sealing clamp • 31/2 S-clamp wraps around body and base sections, which can be easily
and removing the housing head removed for disassembly
• Few components allows for simple maintenance, and easy operation • Designed for use with end fixture codes* C and F
• Lightweight housing can be cleaned by a washing machine • 1TVA Type is compatible with applications that require vented housings
• Designed for use with end fixture codes M, H, and L
S P E C I F I C AT I O N S
S P E C I F I C AT I O N S Model 1TVA-1S-FS 1TVA-2S-FS 1TVA-3S-FS
Model 1TM-1S-MV 1TM-2S-MV Cartridge Capacity 250 mm x 1 500 mm x 1 750 mm x 1
Cartridge Capacity 250 mm x 1 500 mm x 1 Cartridge Compatibility End fixture codes: C and F*
Cartridge Compatibility End fixture codes: M, H, L Inlet/Outlet 1S ferrule
Inlet/Outlet 1" PT Dimensions Height 408 658 908
Dimensions Height 451 704 (mm) Diameter 200
(mm) Diameter 181 Max. Operation Pressure 0.49 MPa (71 psi)
Max. Operation Pressure 0.49 MPa (71 psi) Composition Gasket: Silicon, PTFE Ball Valve: SUS316
Composition O-ring: FPM Head, Body: SU5304 Body, Base, Clamp: SUS304
Weight (kg) 1.8 2.2 Weight (kg) 3.5 5.0 6.5

Note: Use thread-sealing tape on tapered inlet and outlet. Note: Ball valve cannot be sterilized by autoclave. 1TVA-1S-FS
Use thread-sealing tape on tapered inlet and outlet.
1TM-1S-MV, 1TM-2S-MV
O R D E R I N G I N F O R M AT I O N
* Please contact us for information on sanitary housings compatible with
Model 1TM-1S-MV 1TM-2S-MV Plug
other filter cartridge end fixture codes.
Catalog No. 26805010 26805020 Plug O-ring

OUT O R D E R I N G I N F O R M AT I O N
Housing Head Model 1TVA-1S-FS 1TVA-2S-FS 1TVA-3S-FS
IN Catalog No. 26980101 26980102 26980103
Ball Valve

Body O-ring

Clamp
Housing Body

Center Post

Body Gasket
Housing Body
Housing Base

Sealing Nut Gasket


Plug O-ring 3 1/2 S Clamp
Plug Sealing Nut

800-334-7132 w w w. a d v a n t e c m f s . c o m
74 75
C ARTRI DG E H OU S I NG S C ARTRI DG E H OU S I NG S

Sanitar y Stainless Steel Cartridge Housing – 1TWA Type Polypropylene Cartridge Housing – 1PP Type
• Sanitary stainless steel housing for a single cartridge filter, with sanitary • Polypropylene housing for a single cartridge filter, with 3/4" PTF (PT
ferrule type inlet, outlet, and seal for easy inspection and cleaning nipple) type inlet and outlet; high quality and economical
• 4S-clamp wraps around body and base sections; 31/2S-nut seals the top • Suitable for sanitary applications, such as pharmaceutical or high purity
plate and body water filtration; smooth inner walls of housing deter adhesion and
• Designed for use with end fixture codes* C and F accumulation of microbes and minute particles
• Inlet/outlet base of 1TWA Type allows unit be placed on short, straight • Designed for use with end fixture codes* C and F
sections of piping • Several accessories for mounting the unit are available
• Unit head available with push-button vent
S P E C I F I C AT I O N S
Model 1TWA-1S-FS 1TWA-2S-FS 1TWA-3S-FS S P E C I F I C AT I O N S
Cartridge Capacity 250 mm x 1 500 mm x 1 750 mm x 1 Model 1PP-1-FS 1PP-2-FS
Cartridge Compatibility End fixture codes: C and F* Cartridge Capacity 250 mm x 1 500 mm x 1
Inlet/Outlet 1S ferrule Cartridge Compatibility End fixture codes: C and F*
Dimensions Height 412 667 917 Inlet/Outlet
3
/4 " PTF (PT nipple)
(mm) Diameter 183 Dimensions Height 340 594
Max. Operation Pressure 0.49 MPa (71 psi) (mm) Diameter 126
Composition Gasket: Silicon 1TWA-1S-FS Max. Operation Temperature 60°C
Top Plate, Body, Base, Clamp: SUS304 Max. Operation Pressure 0.49 MPa (71 psi) @ 25°C, 1PP-1, 1PP-2
Weight (kg) 5.4 6.9 9.2 0.19 MPa (28 psi) @ 60°C
Note: Ball valve cannot be sterilized by autoclave. Composition Head, Body, Adapter, Drain Cap, Nipple: Polypropylene
Use thread-sealing tape on tapered inlet and outlet. O-ring: Silicone, FPM, Ethylene-propylene Vent,
Adapter Spring: SUS304
* Please contact us for information on sanitary housings compatible with other Weight (kg) 0.84 1.3
filter cartridge end fixture codes. Note: 1PA Type units are made for liquid filtration only and are not suitable for air filtration.
1PA Type units cannot be sterilized by autoclave.
Use thread-sealing tape on tapered inlet and outlet.
O R D E R I N G I N F O R M AT I O N
Model 1TWA-1S-FS 1TWA-2S-FS 1TWA-3S-FS * Please contact us for information on polypropylene housings compatible with
Catalog No. 26980201 26980202 26980203 other filter cartridge end fixture codes.
Sealing Nut

Sealing Nut Gasket


O R D E R I N G I N F O R M AT I O N
Model 1PP-1-FS 1PP-2-FS
Locking Ring Catalog No. 43011000 43021000
Spring

Top Plate OPTIONAL ACCESSORIES


Catalog No. Customize the unit with:
O-ring Housing Stand 1PP-1K (for 1PP-1) 44801010 • Silicone, FPM, or Ethylene-propylene O-rings
(SUS304) 1PP-2K (for 1PP-2) 44801020 • Inlet/outlet pressure gauges
4 S-Clamp Mounting Kit (SUS304) 44801030 • SUS304, PE-coated SUS304, or titanium adapter springs
Tightening Tools 1PP-H (for head) 44801040 • Housing available with SUS304 push-button vent or polypropylene
(PVC) 1PP-B (for body) 44801050 vent (with O-ring seal).
Contact us for more information on these options.
Housing Body

Body Gasket

Housing Base

Sealing Nut Gasket

Sealing Nut

800-334-7132 w w w. a d v a n t e c m f s . c o m
74 75
C ARTRI DG E H OU S I NG S C ARTRI DG E H OU S I NG S

Sanitar y Stainless Steel Cartridge Housing – 1TWA Type Polypropylene Cartridge Housing – 1PP Type
• Sanitary stainless steel housing for a single cartridge filter, with sanitary • Polypropylene housing for a single cartridge filter, with 3/4" PTF (PT
ferrule type inlet, outlet, and seal for easy inspection and cleaning nipple) type inlet and outlet; high quality and economical
• 4S-clamp wraps around body and base sections; 31/2S-nut seals the top • Suitable for sanitary applications, such as pharmaceutical or high purity
plate and body water filtration; smooth inner walls of housing deter adhesion and
• Designed for use with end fixture codes* C and F accumulation of microbes and minute particles
• Inlet/outlet base of 1TWA Type allows unit be placed on short, straight • Designed for use with end fixture codes* C and F
sections of piping • Several accessories for mounting the unit are available
• Unit head available with push-button vent
S P E C I F I C AT I O N S
Model 1TWA-1S-FS 1TWA-2S-FS 1TWA-3S-FS S P E C I F I C AT I O N S
Cartridge Capacity 250 mm x 1 500 mm x 1 750 mm x 1 Model 1PP-1-FS 1PP-2-FS
Cartridge Compatibility End fixture codes: C and F* Cartridge Capacity 250 mm x 1 500 mm x 1
Inlet/Outlet 1S ferrule Cartridge Compatibility End fixture codes: C and F*
Dimensions Height 412 667 917 Inlet/Outlet
3
/4 " PTF (PT nipple)
(mm) Diameter 183 Dimensions Height 340 594
Max. Operation Pressure 0.49 MPa (71 psi) (mm) Diameter 126
Composition Gasket: Silicon 1TWA-1S-FS Max. Operation Temperature 60°C
Top Plate, Body, Base, Clamp: SUS304 Max. Operation Pressure 0.49 MPa (71 psi) @ 25°C, 1PP-1, 1PP-2
Weight (kg) 5.4 6.9 9.2 0.19 MPa (28 psi) @ 60°C
Note: Ball valve cannot be sterilized by autoclave. Composition Head, Body, Adapter, Drain Cap, Nipple: Polypropylene
Use thread-sealing tape on tapered inlet and outlet. O-ring: Silicone, FPM, Ethylene-propylene Vent,
Adapter Spring: SUS304
* Please contact us for information on sanitary housings compatible with other Weight (kg) 0.84 1.3
filter cartridge end fixture codes. Note: 1PA Type units are made for liquid filtration only and are not suitable for air filtration.
1PA Type units cannot be sterilized by autoclave.
Use thread-sealing tape on tapered inlet and outlet.
O R D E R I N G I N F O R M AT I O N
Model 1TWA-1S-FS 1TWA-2S-FS 1TWA-3S-FS * Please contact us for information on polypropylene housings compatible with
Catalog No. 26980201 26980202 26980203 other filter cartridge end fixture codes.
Sealing Nut

Sealing Nut Gasket


O R D E R I N G I N F O R M AT I O N
Model 1PP-1-FS 1PP-2-FS
Locking Ring Catalog No. 43011000 43021000
Spring

Top Plate OPTIONAL ACCESSORIES


Catalog No. Customize the unit with:
O-ring Housing Stand 1PP-1K (for 1PP-1) 44801010 • Silicone, FPM, or Ethylene-propylene O-rings
(SUS304) 1PP-2K (for 1PP-2) 44801020 • Inlet/outlet pressure gauges
4 S-Clamp Mounting Kit (SUS304) 44801030 • SUS304, PE-coated SUS304, or titanium adapter springs
Tightening Tools 1PP-H (for head) 44801040 • Housing available with SUS304 push-button vent or polypropylene
(PVC) 1PP-B (for body) 44801050 vent (with O-ring seal).
Contact us for more information on these options.
Housing Body

Body Gasket

Housing Base

Sealing Nut Gasket

Sealing Nut

800-334-7132 w w w. a d v a n t e c m f s . c o m
76
C ARTRI DG E H OU S I NG S

Acr ylic Cartridge Housing – 1PA Type


VAC U U M F I LTRATION
• Acrylic housing for a single cartridge filter, with 3/4" PF type inlet
and outlet; high quality and economical
• Transparent housing permits observation of filtration process Introduction 78
• Lightweight yet strong construction; can be assembled by hand
Glass Microfiltration: Support Systems 79
• Designed for use with end fixture codes C and F
13 mm Glass Microanalysis Holders 80
S P E C I F I C AT I O N S 25 mm Glass Microanalysis Holders 81
Model 1PA
47 mm Glass Microanalysis Holders 82
Cartridge Capacity 250 mm x 1
Cartridge Compatibility End fixture codes: C and F 47 mm Glass Microanalysis Holders
3
Inlet/Outlet /4 " PF (3/4 "PFM x 3/4 " PTM changeable)
– With All-PTFE Seal 83
Dimensions Height 345
(mm) Diameter 170 47 mm Glass Sterility Test Unit 84
Max. Operation Temperature 38°C 90 mm Glass Microanalysis Holders 85
Max. Operation Pressure 0.5 MPa (73 psi) @ 38°C
Composition Head: Polypropylene Filter Flasks and Stoppers 86
Body: Acrylonitrile Styrene Resin (acrylic)
Body O-ring: Silicone
All-Glass Filtration Assemblies 87
Connector O-ring:NBR Phase/Fraction Collectors 88
Weight (kg) 1.0
Note: - 1PA Type units are made for aqueous filtration only and are
Stainless Steel Filter Holders 89
1PA
not suitable for air or organic solvent filtration. Polysulfone Filter Holders 90
- 1PA Type units cannot be sterilized by autoclave.
- Units include hand-tightening tool as standard accessory. PVC Standard Vacuum Manifolds 92
- Use thread-sealing tape on tapered inlet and outlet.
Head Plug PVC Extraction Manifolds 93
O R D E R I N G I N F O R M AT I O N Plug O-ring Stainless Steel Vacuum Manifolds 94
Head
Model 1PA OUT Vacuum Pressure Pumps 96
Catalog No. 26807000
Connector

Connector O-ring
OPTIONAL ACCESSORIES
Adapter

IN Adapter O-ring

Sealing O-ring

Housing Body

Model ø15mm Hose Adapter L-shape Mounting Kit Housing Stand


Composition Polypropylene SUS304 SUS304
Catalog No. 28801011 28801022 28801012

Plug O-ring

Drain Plug

800-334-7132 800-334-7132