We have done an audit of the 3G Sites CE utilization and CE congestion failure
based on the statistics of last week( 4th-Mar to 10th-Mar)
As the result , we suggest to expand BPN2 borard for 53 sites while 6 of them are high priority.
The expansion threshold: