Anda di halaman 1dari 12

A3G560-AQ41-01

Operating instructions

ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION


Bachmühle 2
D-74673 Mulfingen Read these operating instructions carefully before starting work on the
Phone +49 (0) 7938 81-0 device. Observe the following warnings to prevent malfunctions or
Fax +49 (0) 7938 81-110 danger to persons.
info1@de.ebmpapst.com These operating instructions are to be regarded as part of the device.
www.ebmpapst.com The device is only to be sold or passed on together with the operating
instructions.
CONTENTS These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1. SAFETY REGULATIONS AND INFORMATION 1
1.1 Hazard levels for warnings
1.1 Hazard levels for warnings 1
1.2 Staff qualifications 1 These operating instructions use the following hazard levels to indicate
1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations:
1.4 Voltage 1
DANGER
1.5 Safety and protective features 2
Indicates an imminently hazardous situation which will result in
1.6 Electromagnetic radiation 2
death or serious injury if the specified actions are not taken.
1.7 Mechanical movement 2
Compliance with the instructions is imperative.
1.8 Emissions 2
1.9 Hot surface 2 WARNING
1.10 Transport 2 Indicates a potentially hazardous situation which can result in
1.11 Storage 3 death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
2. INTENDED USE 3
CAUTION
3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which can result in
3.1 Product drawing 4 minor or moderate injury or damage to property if the specified
3.2 Nominal data 5 actions are not taken.
3.3 Data according to Commission Regulation (EU) 327/2011 5 NOTE
3.4 Technical description 5 A potentially harmful situation can occur and, if not avoided, can
3.5 Mounting data 6 lead to property damage.
3.6 Transport and storage conditions 6
3.7 Electromagnetic compatibility 6 1.2 Staff qualifications
4. CONNECTION AND STARTUP 6 The device may only be transported, unpacked, installed, operated,
4.1 Mechanical connection 6 maintained and otherwise used by suitably qualified, trained and
4.2 Electrical connection 6 authorized technical staff.
4.3 Connecting the cables 7 Only authorized specialists are permitted to install the device, to carry
4.4 Factory settings 8 out a test run and to perform work on the electrical installation.
4.5 Connection diagram 9
1.3 Basic safety rules
4.6 Checking connections 10
4.7 Switching on the device 10 The safety hazards associated with the device must be assessed again
4.8 Switching off the device 10 following installation in the final product.
The locally applicable industrial safety regulations are always to be
Translation of the original operating instructions

5. INTEGRATED PROTECTIVE FEATURES 10 observed when working on the device.


Keep the workplace clean and tidy. Untidiness in the work area
6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 10 increases the risk of accidents.
CAUSES AND REMEDIES Note the following when working on the device:
6.1 Cleaning 11
; Do not perform any modifications, additions or conversions on the
6.2 Safety inspection 11
device without the approval of ebm-papst.
6.3 Disposal 11
1.4 Voltage
; Check the device's electrical equipment at regular intervals; see
Chapter 6.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 1 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

WARNING 1.7 Mechanical movement


Live terminals and connections even with device
switched off DANGER
Electric shock Rotating device
Risk of injury to body parts coming into contact with the rotor or
→ Wait five minutes after disconnecting the voltage at all poles
the impeller.
before opening the device.
→ Secure the device against accidental contact.
CAUTION
→ Before working on the system/machine, wait until all
In the event of a fault, the rotor and the impeller will be
parts have come to a standstill.
energized
The rotor and the impeller have basic insulation. DANGER
→ Do not touch the rotor and impeller once installed. Ejected parts
Missing protective devices may cause balancing weights or
CAUTION broken fan blades to be ejected and cause injuries.
If control voltage or a stored speed set value is applied,
→ Take appropriate safety measures.
the motor will restart automatically, e.g. after a power
failure. WARNING
Risk of injury Rotating device
→ Keep out of the device’s danger zone.# When working on Long hair and dangling items of clothing, jewelry and the like
the device, switch off the line voltage and ensure that it can become entangled and be pulled into the device. Injuries
cannot be switched back on. can result.
→ Wait until the device comes to a stop. → Do not wear any loose-fitting or dangling clothing or jewelry
while working on rotating parts.
→ After working on the device, remove any tools or other
objects from the device. → Protect long hair with a cap.

1.5 Safety and protective features 1.8 Emissions

DANGER WARNING
Protective device missing and protective device not Depending on the installation and operating conditions,
functioning the sound pressure level may exceed 70 dB(A).
Without a protective device there is a risk of serious injury, for Risk of noise-induced hearing loss
instance if the hands reach or are sucked into the device during → Take appropriate technical safety measures.
operation. → Protect operating personnel with appropriate safety
→ Operate the device only with a fixed protective device and equipment such as hearing protection.
guard grille. → Also observe the requirements of local agencies.
→ The fixed protective device must be able to withstand the
kinetic energy of a fan blade that becomes detached at 1.9 Hot surface
maximum speed. There must not be any gaps which it is
possible to reach into with the fingers, for example. CAUTION
High temperature on electronics housing
→ The device is a built-in component. As the operator, you Risk of burns
are responsible for ensuring that the device is secured
adequately. → Ensure sufficient protection against accidental contact.
Translation of the original operating instructions

→ Stop the device immediately if you notice a missing or 1.10 Transport


ineffective protective device.
WARNING
1.6 Electromagnetic radiation Transporting the fan
Injuries from tipping or slipping
Interference from electromagnetic radiation is possible, e.g. in conjunction
with open- and closed-loop control devices. → Wear safety shoes and cut-resistant safety gloves. #The fan
If impermissible radiation levels occur following installation, appropriate is only to be transported in its original packaging. #The fan is
shielding measures have to be taken by the user. to be transported lying flat, i.e. the motor axis must be
vertical. #Secure the fan(s) e.g. with a lashing strip to stop
NOTE anything slipping or tipping.
Electrical or electromagnetic interference after installing
the device in customer equipment.
→ Verify that the entire setup is EMC-compliant.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 2 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

1.11 Storage ● Using the device as a safety component or to perform safety-related


functions.
; Store the device, partially or fully assembled, in a dry place,
protected against the weather and free from vibration, in the original ● Operation with completely or partially disassembled or manipulated
packaging in a clean environment. protective devices.
; Protect the device against environmental effects and dirt until final ● In addition, all applications not listed among the intended uses.
installation.
; We recommend storing the device for no longer than one year in
order to guarantee trouble-free operation and the longest possible
service life.
; Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.
; Maintain the storage temperature, see
Chapter 3.6 Transport and storage conditions.

2. INTENDED USE
The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.
Intended use also includes
● Using the device only in power systems with grounded neutral (TN/
TT power systems).
● The device is to be used in networks with network quality
characteristics as per EN 50160.
● Using the device only in stationary systems.
● Performing all maintenance work.
● Conveying air at an ambient air pressure between 800 mbar and
1050 mbar.
● Using the device within the permitted ambient temperature range; see
Chapter 3.6 Transport and storage conditions and
Chapter 3.2 Nominal data.
● Operating the device with all protective devices.
● Following the operating instructions.
Translation of the original operating instructions

Improper use
In particular, operating the device in the following ways is prohibited and
could be hazardous:
● Operating the device in an unbalanced state, e.g. due to dirt deposits
or ice formation.
● Resonant operation, operation with severe vibration. This also
includes vibration transmitted to the fan from the customer installation.
● Operation in medical equipment with a life-sustaining or life-support
function.
● Conveying solids in the flow medium.
● Painting the device
● Connections (e.g. screws) coming loose during operation.
● Conveying air that contains abrasive particles.
● Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.
● Conveying air with high dust content, e.g. suctioning off sawdust.
● Operating the device close to flammable materials or components.
● Operating the device in an explosive atmosphere.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 3 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1 Direction of air flow "V"


2 Max. clearance for screw 16 mm
3 Cable PVC AWG18, 6x crimped ferrules
4 Cable PVC AWG22, 3x crimped ferrules
Translation of the original operating instructions

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 4 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

3.2 Nominal data 3.4 Technical description


Motor M3G112-GA Weight 10.1 kg
Size 560 mm
Phase 3~ Motor size 112
Nominal voltage / VAC 400 Rotor surface Painted black
Nominal voltage 380 .. 480 Electronics housing Die-cast aluminum, painted black
range / VAC material
Frequency / Hz 50/60 Blade material Sheet aluminum insert, sprayed with PP
Method of obtaining ml plastic
data Number of blades 5
Speed (rpm) / min-1 1350 Blade pitch -5°
Power consumption / W 945 Airflow direction V
Current draw / A 1.5 Direction of rotation Counterclockwise, viewed toward rotor
Min. ambient -25 Degree of protection IP54
temperature / °C Insulation class "B"
Max. ambient 60 Moisture (F) / H2
temperature / °C Environmental (H)
ml = Max. load · me = Max. efficiency · fa = Free air protection class
cs = Customer specification · ce = Customer equipment Installation position Shaft horizontal or rotor on bottom; rotor
Subject to change on top on request
Condensation On rotor side
3.3 Data according to Commission Regulation (EU) 327/ drainage holes
2011 Mode S1
Actual Req. 2015
Motor bearing Ball bearing
01 Overall efficiency ηes / % 42.9 33.5 Technical features - Output 10 VDC, max. 10 mA
- Alarm relay
02 Measurement category A
- Integrated PID controller
03 Efficiency category Static
- Motor current limitation
04 Efficiency grade N 49.4 40
- PFC, passive
05 Variable speed drive Yes - Soft start
06 Year of manufacture The year of manufacture is specified on the
product's rating label. - Control input 0-10 VDC / PWM
07 Manufacturer ebm-papst Mulfingen GmbH & Co. KG - Control interface with SELV potential
Amtsgericht (court of registration) Stuttgart safely disconnected from supply
· HRA 590344 - Thermal overload protection for
D-74673 Mulfingen
electronics/motor
08 Type A3G560-AQ41-01
- Line undervoltage / phase failure
09 Power consumption Ped / kW 0.93
detection
09 Air flow qv / m³/h 7890
Touch current <= 3.5 mA
09 Pressure increase total psf / 168 according to IEC
Pa 60990 (measuring
10 Speed (rpm) n / min-1 1360 circuit Fig. 4, TN
Translation of the original operating instructions

11 Specific ratio* 1.05 system)


12 Recycling/disposal Information on recycling and disposal is
provided in the operating instructions.
Motor protection Thermal overload protector (TOP)
13 Maintenance Information on installation, operation and internally connected
maintenance is provided in the operating with cable Variable
instructions.
Protection class I (with customer connection of protective
14 Additional components Components used to calculate the energy
efficiency that are not apparent from the earth)
measurement category are detailed in the Conformity with CE
CE declaration. standards
* Specific ratio = 1 + pfs / 100 000 Pa Approval EAC; CCC
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
; Use the device in accordance with its degree of protection.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 5 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

Information on surface quality 4. CONNECTION AND STARTUP


The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period. 4.1 Mechanical connection
This has no effect on strength, dimensional stability and dimensional
accuracy. CAUTION
The color pigments in the paints used perceptibly react to UV light over Cutting and crushing hazard when removing fan from
the course of time. This does not however in any way affect the packaging
technical properties of the products. The product is to be protected against → Carefully remove the device from its packaging, grasping it
UV radiation to prevent the formation of patches and fading. Changes in by only the blades near the hub. Strictly avoid shocks.
color are not a reason for complaint and are not covered by the warranty. → Wear safety shoes and cut-resistant safety gloves.
3.5 Mounting data CAUTION
Heavy load when unpacking device
; Secure the screws against unintentional loosening (e.g. use self- Risk of physical injury, such as back injuries.
locking screws).
→ Two people should work together to remove the device from
For screw clearance, see Chapter 3.1 Product drawing its packaging.
Strength class of 8.8 CAUTION
screws The blades of the impeller could be damaged.
Any further mounting data required can be taken from the product → Carefully set down the fan on a soft surface. Make sure the
drawing or Section Chapter 4.1 Mechanical connection. blades are not subjected to load. #Following installation,
make sure the impeller moves easily and that the blades of
3.6 Transport and storage conditions
the impeller are not deformed or bent and do not catch at any
Max. permitted 80 °C point.
ambient temp. for NOTE
motor (transport/ Damage to the device from vibration
storage) Bearing damage, shorter service life
Min. permitted -40 °C
→ The fan must not be subjected to force or excessive vibration
ambient temp. for
from sections of the installation. #If the fan is connected to air
motor (transport/
ducts, the connection should be isolated from vibration, e.g.
storage)
using compensators or similar elements. #Ensure stress-free
attachment of the fan to the substructure.
3.7 Electromagnetic compatibility
; Check the device for transport damage. Damaged devices are not to
EMC immunity to According to EN 61000-6-2 (industrial be installed.
interference environment) ; Install the undamaged device in accordance with your application.
EMC circuit feedback According to EN 61000-3-2/3
EMC interference According to EN 61000-6-4 (industrial CAUTION
emission environment) Possible damage to the device
If the device slips during installation, serious damage can result.
If several devices are switched in parallel on the supply side
→ Ensure that the device is securely positioned at its place of
so that the line current of the arrangement is in the range of 16-
installation until all fastening screws have been tightened.
75 A, then this arrangement conforms to IEC 61000-3-12
The fan must not be strained on fastening.
Translation of the original operating instructions

provided that the short-circuit power Ssc at the connection point ●


of the customer system to the public power system is greater
than or equal to 120 times the rated output of the arrangement.
4.2 Electrical connection
It is the responsibility of the installation engineer or operator/ DANGER
owner of the device to ensure, if necessary after consultation Voltage on the device
with the network operator, that this device is only connected to Electric shock
a connection point with a Ssc value that is greater than or equal
→ Always connect a protective earth first.
to 120 times the rated output of the arrangement.
→ Check the protective earth.
DANGER
Faulty insulation
Risk of fatal injury from electric shock
→ Use only cables that meet the specified installation
regulations for voltage, current, insulation material, capacity,
etc.
→ Route cables so that they cannot be touched by any
rotating parts.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 6 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

DANGER 3/PE AC 20 A 20 A C20A 2.5 14


Electrical charge (>50 µC) between phase conductor and 380-480
protective earth connection after switching off supply VAC
with multiple devices connected in parallel. 3/PE AC 25 A 25 A C25A 4.0 12
Electric shock, risk of injury 380-480
→ Ensure sufficient protection against accidental contact. VAC
Before working on the electrical hookup, short the supply * AWG = American Wire Gauge
and PE connections.
CAUTION 4.2.3 Reactive currents
Voltage Because of the EMC filter integrated for compliance with EMC
The fan is a built-in component and has no disconnecting switch. limits (interference emission and immunity to interference),
→ Only connect the fan to circuits that can be switched off with reactive currents can be measured in the supply line even
an all-pole disconnection switch. when the motor is at a standstill and the line voltage is switched
→ When working on the fan, secure the system/machine in on.
which the fan is installed so as to prevent it from being ● The values are typically in the range < 250 mA
switched back on. ● At the same time, the effective power in this operating state
NOTE (operational readiness) is typically < 5 W.
Device malfunctions possible
Route the device's control lines separately from the supply line. 4.2.4 Residual current circuit breaker (RCCB)

→ Maintain the greatest possible clearance. If the use of a residual current device (RCD) is required in your
Recommendation: clearance > 10 cm (separate cable installation, only AC/DC-sensitive residual current devices
routing) (type B or B+) are permissible. As with variable frequency
drives, residual current devices cannot provide personal safety
NOTE
while operating the device. When the device power supply is
Water ingress into wires or cables
switched on, pulsed charging currents from the capacitors in the
Water ingress at the customer end of the cable can damage the
integrated EMC filter can lead to the instant tripping of residual
device.
current devices. We recommend the use of residual current
→ Make sure the end of the cable is connected in a dry circuit breakers (RCCB) with a trip threshold of 300 mA and
environment. delayed tripping (super-resistant, characteristic K).
Only connect the device to circuits that can be switched off with
4.2.5 Leakage current
an all-pole disconnection switch.
For asymmetrical power systems or if a phase fails, the
4.2.1 Requirements leakage current can increase to a multiple of the nominal value.

; Check whether the information on the nameplate matches the


connection data. 4.2.6 Locked-rotor protection
; Before connecting the device, make sure the power supply matches Due to the locked-rotor protection, the starting current (LRA) is
the device voltage. equal to or less than the nominal current (FLA).
; Only use cables designed for the current level indicated on the
nameplate. 4.3 Connecting the cables
Translation of the original operating instructions

For determining the cross-section, note the sizing criteria according


to EN 61800-5-1. The protective earth must have a cross-section The device has external leads.
equal to or greater than that of the phase conductor. ; First connect the "PE" (protective earth).
We recommend the use of 105 °C cables. Ensure that the minimum ● Connect the cables according to your application. When doing so,
cable cross-section is at least observe Chapter 4.5 Connection diagram.
AWG 26 / 0.13 mm².
4.3.1 Cable routing
4.2.2 Supply connection and fuses
Water must be prevented from reaching the cable exit along the cable.
Assignment of supply cable cross-sections and their required fuses (line
protection only, no equipment protection). NOTE
Damage caused by moisture penetration.
Nominal Fuse Automatic Cable Cable Moisture can penetrate into the terminal box if water is
voltage circuit cross- cross- constantly present at the cable glands.
breaker section section
VDE UL VDE mm² *AWG → To prevent the constant accumulation of water at the cable
glands, the cable should be routed in a U-shaped loop
3/PE AC 16 A 15 A C16A 1.5 16
wherever possible.# If this is not possible, a drip edge can
380-480
be produced by fitting a cable tie directly in front of the cable
VAC
gland for example.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 7 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

Fans installed lying flat

Fig. 1: Fan installed lying flat, cable routed in a U-shaped loop.


; Make sure the cable is routed in a U-shaped loop.
; Avoid kinks or bends in the bushing.

Fans installed upright

Fig. 2: Cable routing for fans installed upright.


The cables must always be routed downward.

4.4 Factory settings


Factory settings made for the device by ebm-papst.
Mode PWM control
Translation of the original operating instructions

Group address 1
Fan/device address 1
Max. PWM / % 100
Min. PWM / % 0
Save set value to Yes
EEPROM
Set value requirement Analog
Direction of action Positive (heating)

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 8 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

4.5 Connection diagram

Drawing preliminary!

No. Conn. Designation Color Function/assignment


1 1, 2 PE green/ Protective earth
yellow
1 3, 4, 5 L1, L2, L3 black Power supply 50 / 60 Hz
1 6 COM white 1 Floating status contact, break for failure (2A, max. 250 VAC, min. 10 mA, AC1)
1 7 NC white 2 Floating status contact, break for failure
2 8 0 - 10 V yellow Control input, set value 0-10 VDC, impedance 100 kOhm, SELV
2 11 + 10 V red Voltage output 10 VDC (±3%), max. 10 mA, power supply for external devices (e.g.
potentiometers), SELV
Translation of the original operating instructions

2 12 GND blue Reference ground for control interface, SELV

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 9 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

4.6 Checking connections 5. INTEGRATED PROTECTIVE FEATURES


; Ensure isolation from supply (all phases). The integrated protective functions cause the motor to switch off
; Make sure a restart is impossible automatically in the event of the faults described in the table.
; Check the cables for proper fit. Fault Safety feature description/
function
4.7 Switching on the device Rotor position detection error An automatic restart follows.
The device may only be switched on if it has been installed properly and Blocked rotor ; After the blockage is
in accordance with its intended use, including the required safety removed, the motor restarts
mechanisms and professional electrical hookup. This also applies for automatically.
devices which have already been equipped with plugs and terminals or Line undervoltage (line voltage ; If the line voltage returns to
similar connectors by the customer. outside of permitted nominal permitted values, the motor
voltage range) restarts automatically.
WARNING
Phase failure A phase of the supply voltage
Hot motor housing
fails for at least 5 s.
Risk of fire
; When all phases are
→ Ensure that no combustible or flammable materials are correctly supplied again, the
located close to the fan. motor automatically restarts after
; Before switching on, check the device for visible external damage 10-40 s.
and make sure the protective devices are functional.
; Check the fan's air flow paths for foreign matter and remove any
foreign matter found. 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE
; Apply the nominal supply voltage.
CAUSES AND REMEDIES
; Start the device by changing the input signal.
Do not perform any repairs on your device. Send the device to ebm-
NOTE papst for repair or replacement.
Damage to the device from vibration
Bearing damage, shorter service life WARNING
Live terminals and connections even with device
→ Low-vibration operation of the fan must be ensured over the
switched off
entire speed control range. #Severe vibration can arise for
Electric shock
instance from inexpert handling, transportation damage and
resultant imbalance or be caused by component or structural → Wait five minutes after disconnecting the voltage at all poles
resonance. #Speed ranges with excessively high vibration before opening the device.
levels and possibly resonant frequencies must be CAUTION
determined in the course of fan commissioning. #Either run If control voltage or a stored speed set value is applied,
through the resonant range as quickly as possible with the motor will restart automatically, e.g. after a power
speed control or find another remedy.# Operation with failure.
excessively high vibration levels can lead to premature Risk of injury
failure.
→ Keep out of the device’s danger zone.# When working on
4.8 Switching off the device the device, switch off the line voltage and ensure that it
cannot be switched back on.
Switching off the device during operation:
Translation of the original operating instructions

→ Wait until the device comes to a stop.


; Switch off the device via the control input.
→ After working on the device, remove any tools or other
; Do not switch the motor (e.g. in cyclic operation) on and off via power objects from the device.
supply.
If the device is out of use for some time, e.g. when in storage,
Switching off the device for maintenance: we recommend switching it on for at least two hours to allow
; Switch off the device via the control input. any condensation to evaporate and to move the bearings.
; Do not switch the motor (e.g. in cyclic operation) on and off via power Malfunction/fault Possible cause Possible remedy
supply. Impeller not Imbalance in rotating Clean the device;
; Disconnect the device from the power supply. running smoothly parts replace it if imbalance
; When disconnecting, be sure to disconnect the ground connection last. persists after cleaning.
Make sure no
weight clips are
removed during
cleaning.
Motor not turning Mechanical blockage Switch off, isolate
from supply and
remove mechanical
blockage.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 10 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

Line voltage faulty Check line voltage, In the event of further malfunctions, contact ebm-papst.
restore power supply.
Attention! The error
message resets
6.1 Cleaning
automatically.
Device restarts NOTE
automatically without Damage to the device during cleaning
warning. Malfunction possible
Faulty connection Isolate from supply, → Do not clean the device using a water jet or high-pressure
correct connection; cleaner.
see connection
diagram. → Do not use any acid, alkali or solvent-basedcleaning
Broken motor winding Replace device agents.
Thermal overload Allow motor to cool → Do not use any pointed or sharp-edged objects for cleaning
protector activated off, locate and rectify
cause of error, 6.2 Safety inspection
release restart lockout NOTE
if necessary High-voltage test
Deficient cooling Improve cooling. Let The integrated EMC filter has Y capacitors. The tripping current
the device cool down. is exceeded when AC testing voltage is applied.
To reset the error
→ Test the device with DC voltage when you perform the
message, switch off
legally required high-voltage test. The voltage to be used
the line voltage for at
corresponds to the peak value of the AC voltage required by
least 25 s and then
the standard.
switch it on again.
Alternatively, reset What to check How to check How often What action?
the error message by Contact Visual inspection At least every Repair or
applying a control protection 6 months replacement of
signal of < 0.5 V to cover for device
Din1 or by shorting intactness or
Din1 to GND. damage
Ambient temperature Reduce the ambient Device for Visual inspection At least every Replacement of
too high temperature. Let the damage to 6 months device
device cool down. blades and
To reset the error housing
message, switch off Fastening the Visual inspection At least every Fasten
the line voltage for at cables 6 months
least 25 s and then Fastening the Visual inspection At least every Fasten
switch it on again. protective earth 6 months
Alternatively, reset terminal
the error message by Insulation of Visual inspection At least every Replace cables
applying a control cables for 6 months
signal of < 0.5 V to
Translation of the original operating instructions

damage
Din1 or by shorting Condensation Visual inspection At least every Open holes
Din1 to GND. drainage holes 6 months
Impermissible point of Correct the operating for clogging,
operation (e.g. back point. Let the device where necessary
pressure too high) cool down. Welds for crack Visual inspection At least every Replace device
To reset the error formation 6 months
message, switch off
Abnormal acoustic At least every Replace device
the line voltage for at
bearing noise 6 months
least 25 s and then
switch it on again.
Alternatively, reset 6.3 Disposal
the error message by For ebm-papst, environmental protection and resource preservation are
applying a control top priority corporate goals.
signal of < 0.5 V to ebm-papst operates an environmental management system which is
Din1 or by shorting certified in accordance with ISO 14001 and rigorously implemented
Din1 to GND. around the world on the basis of German standards.
Right from the development stage, ecological design, technical safety
and health protection are fixed criteria.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 11 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A3G560-AQ41-01
Operating instructions

The following section contains recommendations for ecological disposal


of the product and its components.
6.3.1 Country-specific legal requirements
NOTE
Country-specific legal requirements
Always observe the applicable country-specific legal
regulations with regard to the disposal of products or waste
occurring in the various phases of the life cycle. The
corresponding disposal standards are also to be heeded.

6.3.2 Disassembly
Disassembly of the product must be performed or supervised by
qualified personnel with the appropriate technical knowledge.
The product is to be disassembled into suitable components for disposal
employing standard procedures for motors.
WARNING
Heavy parts of the product may drop off. Some of the
product components are heavy. These components
could drop off during disassembly.
This can result in fatal or serious injury and material damage.
→ Secure components before unfastening to stop them falling.

6.3.3 Component disposal


The products are mostly made of steel, copper, aluminum and plastic.
Metallic materials are generally considered to be fully recyclable.
Separate the components for recycling into the following categories:
● Steel and iron
● Aluminum
● Non-ferrous metal, e.g. motor windings
● Plastics, particularly with brominated flame retardants, in accordance
with marking
● Insulating materials
● Cables and wires
● Electronic scrap, e.g. circuit boards
Only ferrite magnets and not rare earth magnets are used in external
rotor motors from ebm-papst Mulfingen GmbH & Co. KG.
; Ferrite magnets can be disposed of in the same way as normal iron
and steel.
Translation of the original operating instructions

Electrical insulating materials on the product, in cables and wires are


made of similar materials and are therefore to be treated in the same
manner.
The materials concerned are as follows:
● Miscellaneous insulators used in the terminal box
● Power cables
● Cables for internal wiring
● Electrolytic capacitors
Dispose of electronic components employing the proper procedures for
electronic scrap.

→ Please contact ebm-papst for any other questions on disposal.

Item no. 50223-5-9970 · ENU · Change 99339 · Approved 2018-04-26 · Page 12 / 12