1910.36(a)(1)
Exit Routes:
Exit enclosure
Two - hour fire
Basic Requirements resistance –
rating for four or
An exit must more stories.
be
separated
by fire
resistant One - hour fire
materials. resistance - rating:
three or fewer stories
1910.36(a)(2)
Exit Routes:
Protected
Basic Requirements exit stair
tower
• Openings into an exit must
be limited to those
necessary to allow access to
the exit or to the exit
discharge
• An opening into an exit must
be protected by an approved
self-closing fire door that
remains closed or
automatically closes in an
emergency 1910.36(a)(3)
The number of
exit routes must
be adequate. Remotely
Normally two or located to
more depending on provide
•the size of the options for
building, evacuation
•its occupancy, or
•the arrangement
of the workplace
1910.36(b)
Exit discharge
. . . must lead directly outside or to a street,
walkway, refuge area, public way, or open
space with access to the outside . . .(This
area) must be large enough . . .
Exit Discharge
Offices Storage
EXIT
• penal, or
• correctional facilities
where there is constant
supervision and the
employer has a plan to
remove occupants from the
facility during an
emergency.
1910.36 (d)(3)
Side-Hinged Exit Door
Must be used to connect any
room to an exit route
A door that connects any
room to an exit route must
swing out in the
direction of exit travel if
• the room is designed to be
occupied by more than
50 people or
• contains high hazard
contents
1910.36 (f)(1)
Exit Route Capacity and Dimensions
Capacity
must not
decrease
in the
direction of
exit route
travel to
the exit
discharge
1910.36 (f)(2)
Exit Route Capacity and Dimensions
7-½ ft.
• Ceiling must be
at least 7-½ ft. 6 ft.- 8 in.
high with no
projection
reaching a point
less than 6 ft.- 8
in. from floor
• An exit access
must be at least
28 in. wide at all
points
1910.36 (g)(1) and (2)
Typical Occupant Load Factors
Use (per person)
Assembly Use
•Concentrated use 7 ft2 net
without fixed seating
•Less concentrated use, 15 ft2 net
without fixed seating
•Bench-type seating 1 person/18
linear inches
•Fixed seating # of fixed seats
Typical Occupant Load Factors, cont’d
Use (per person)
Assembly Use
• Waiting spaces 3 ft2 net –
(Restricted -
See NFPA 101 Ch. 13)
in. in.
Board and care 0.4 0.2
Health care 0.3 0.2
•sprinklered
•Non-sprinklered 0.6 0.5
High hazard 0.7 0.4
Contents
All others 0.3 0.2
Exit Route Capacity and Dimensions
1910.36 (g)(4)
Minimize Danger to Employees
Exit routes must be kept free of explosive
or highly flammable furnishings or
other decorations.
1910.37 (a)(1)
Minimize Danger to Employees
1910.37 (a)(3)
Minimize Danger to
1910.37 (a)(2) and (4) Employees
• Arrange exit routes so that
employees will not have
to travel toward a high
hazard area, unless it is
effectively shielded
• Emergency safeguards
(e.g., sprinkler systems,
alarm systems, fire doors,
exit lighting) must be in
proper working order at
all times
Lighting and marking must be adequate
and appropriate.
• Each exit must be clearly
visible and marked with an
“Exit” sign
1910.37 (b)(4)
Lighting and marking must be
adequate and appropriate.
Each doorway or passage along
an exit access that could be
mistaken for an exit must be
marked “Not an Exit” or
similar designation, or be
identified by a sign indicating its
actual use (e.g., closet).
1910.37 (b)(5)
Lighting and marking must be adequate
and appropriate.
Exit routes must be maintained during
construction, repairs, or alterations
. . . Employees must
not occupy a
workplace until the
exit routes . . . are
completed and
ready for
employee use . . .
1910.37 (d)(1)
Exit routes must be maintained during
construction, repairs, or alterations
Employees must not be exposed to hazards of
flammable or explosive substances or
equipment used during construction, repairs, or
alterations, that are beyond the normal permissible
conditions in the workplace, or that would impede
exiting the workplace.
(b) Written and oral emergency
action plans.
An emergency action plan must
be in writing, kept in the
workplace, and available to
employees for review.
However, anemployer with
10 or fewer employees may
communicate the plan orally
to employees.
(c) Minimum elements of an emergency
action plan.
An emergency action
plan must include
at a minimum:
(1) Procedures
for reporting a
fire or other
emergency;
(c) Minimum elements of an
emergency action plan.
(4) Procedures to
account for all
employees after
evacuation;
Verify that
employees
are safe.
(c) Minimum elements of an
emergency action plan.
(5) Procedures to
be followed by
employees
performing
rescue or
medical duties;
and
(c) Minimum elements of an emergency
action plan.
(6) The name or job
title of every
employee who What do I
may be do??
contacted by
employees who
need more We do
information about this!
the plan or an
explanation of their
duties under the
plan.
(d) Employee alarm system.
An employer
must have and
maintain an
employee
alarm system.
(d) Employee alarm system.
. . .The employee
alarm system must
use a
distinctive
signal for each
purpose and
comply with
the requirements in
§ 1910.165.
(e) Training.
An employer must
designate and
train
employees to
assist in a safe
and orderly
evacuation of
other employees.
(f) Review of emergency action plan.
An employer must review the . . .
EAP. . . with each employee
covered by the plan:
(1) When the plan is
developed or the
employee is assigned
initially to a job;
(2) When the employee's
responsibilities under the Informing
plan change; and employees
• Application
• The name or job title of employees responsible for the control of fuel source
hazards.
1910.39 Fire Prevention Plans
• Employee information