Bolt H K Bolt H K
Note : 1. Length of stud bolt (LS) inlcude the height of the points.
3. Length of stud bolt (LS) shall be extended when spacer and blank is applied.
Page 2 of 13
BOLT AND NUT DIMENSION FOR FLANGE
CLASS ( RF )
Bolt H K Bolt H K
Note :
3. Length of stud bolt (LS) shall be extended when spacer and blank is applied.
Page 3 of 13
ATTACHMENT - 3
FIG. - 8 AND SPACER & BLANK DIMENSION TABLE
CLASS 150
A
W
Note 6
FIG. - 8 BLANK
Wt
T
B O
Note :
1 Fig. - 8 Blanks dimensions conform to API 590, except thickness T.
2 The thickness of the web (tie bar) shall be 1/4 Inches minimum except when T is less than 1/4 Inches then Wt shall be equal to T.
3 To be installed between flanges as per ASME B16.5. (Flanges with jackscrew assembly for NPS 4 and over).
4 Gasket contact suface shall be 125 to 320 RMS as per ASME B46.1.
5 For dimensional tolerances refer attachment-6
6 Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole.
7 All units are in inches unless for value equal to and/or larger than 12" shall use combination of feet(s) and inches.
(As indicated on table)
Page 5 of 13
CLASS 150
HANDLE DETAIL "A" OR "B"
SPACER BLANKS
T
B O
O
HANDLE DETAIL
2" x 1/4" BAR TACK
PL 1/4" 5/8" f ROD WELDED TO ROCK
1/2" f HOLE 1"
NOTE (5) 3"
1/2"
NOTE (6)
2 1/2"
5/8"
NOTE (6)
8"
8"
5/8"
3/16 3/16
Notes :
1 Spacer and Blank dimensions conform to API 590, except thickness T.
2 To be installed between flanges as per ASME B16.5, with jackscrew assembly.
3 Gasket contact surface shall be 125 to 320 RMS as per ASME B46.1.
4 For dimensional tolerances refer attachment-6
5 To be die stamped 'SPACER' and 'BLANK' on each item respectively.
6 Pipe size, flange rating and material to be die stamped on the handle.
7 All units are in inches unless for value equal to and/or larger than 12" shall use combination of feet(s) and inches.
(As indicated on table)
Page 6 of 13
CLASS 300
A
W
Note 6
FIG. - 8 BLANK
Wt
T
B O
Note :
1 Fig. - 8 Blanks dimensions conform to API 590, except thickness T.
2 The thickness of the web (tie bar) shall be 1/4 Inches minimum except when T is less than 1/4 Inches then Wt shall be equal to T.
3 To be installed between flanges as per ASME B16.5. (Flanges with jackscrew assembly for NPS 4 and over).
4 Gasket contact suface shall be 125 to 320 RMS as per ASME B46.1.
5 For dimensional tolerances refer attachment-6
6 Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole.
7 All units are in inches unless for value equal to and/or larger than 12" shall use combination of feet(s) and inches.
(As indicated on table)
Page 7 of 13
CLASS 300
HANDLE DETAIL "A" OR "B"
SPACER BLANKS
T
B O
O HANDLE DETAIL
50 x 6 BAR TACK
16 f ROD WELDED TO ROCK
NOTE (5) 76
NOTE (6)
64
200
5
Notes :
1 Spacer and Blank dimensions conform to API 590, except thickness T.
2 To be installed between flanges as per ASME B16.5, with jackscrew assembly.
3 Gasket contact surface shall be 125 to 320 RMS as per ASME B46.1.
4 For dimensional tolerances refer attachment-6
5 To be die stamped 'SPACER' and 'BLANK' on each item respectively.
6 Pipe size, flange rating and material to be die stamped on the handle.
7 All units are in inches unless for value equal to and/or larger than 12" shall use combination of feet(s) and inches.
(As indicated on table)
Page 8 of 13
CLASS 600
A
W
Note 6
FIG. - 8 BLANK
Wt
T
B O
Note :
1 Fig. - 8 Blanks dimensions conform to API 590, except thickness T.
2 The thickness of the web (tie bar) shall be 1/4 Inches minimum except when T is less than 1/4 Inches then Wt shall be equal to T.
3 To be installed between flanges as per ASME B16.5. (Flanges with jackscrew assembly for NPS 4 and over).
4 Gasket contact suface shall be 125 to 320 RMS as per ASME B46.1.
5 For dimensional tolerances refer attachment-6
6 Hole size (where required due to bolt spacing) shall be the same as the flange bolt hole.
7 All units are in inches unless for value equal to and/or larger than 12" shall use combination of feet(s) and inches.
(As indicated on table)
Page 9 of 13
CLASS 600
SPACER BLANKS
T
B O
O HANDLE DETAIL
50 x 6 BAR TACK
16 f ROD WELDED TO ROCK
NOTE (5) 76
NOTE (6)
64
200
5
Notes :
1 Spacer and Blank dimensions conform to API 590, except thickness T.
2 To be installed between flanges as per ASME B16.5, with jackscrew assembly.
3 Gasket contact surface shall be 125 to 320 RMS as per ASME B46.1.
4 For dimensional tolerances refer attachment-6
5 To be die stamped 'SPACER' and 'BLANK' on each item respectively.
6 Pipe size, flange rating and material to be die stamped on the handle.
7 All units are in inches unless for value equal to and/or larger than 12" shall use combination of feet(s) and inches.
(As indicated on table)
Page 10 of 13
ATTACHMENT - 4
TOLERANCES FOR SPACERS AND BLANKS
Attachment-6
ID O D
T
(R F .L J )
O D
+0
300 AND UNDER - 1.0
+0