Anda di halaman 1dari 687

Ver.

LTE eNB

Call Parameter Description


COPYRIGHT
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright.
No information contained herein may be copied, translated, transcribed or duplicated for any commercial
purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics
Co., Ltd.

TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective
companies.

This manual should be read and used as a guideline for properly installing and operating the product.

All reasonable care has been made to ensure that this document is accurate. If you have any comments on
this manual, please contact our documentation centre at the following address:

Address: Document Center 3rd Floor Jeong-bo-tong-sin-dong. 129, Samsung-ro, Yeongtong-gu, Suwon-si,
Gyeonggi-do, Korea 443-742
Homepage: http://www.samsungdocs.com

©2013 SAMSUNG Electronics Co., Ltd. All rights reserved.


LTE eNB Call Parameter Description

INTRODUCTION

Purpose
This manual is for the purpose of understanding for parameter Description in the S
amsung LTE eNB

Audience
The audience of this parameter Description is the Samsung LTE eNB operators.

Document Content and Organization


CHAPTER 1. Overview
This chapter describes Overview of Parameter Description.
 Description of entries
 Main body of parameter entries

CHAPTER 2. Parameter Description


This chapter describes the parameters used in Call Processing features. These param
eters are arranged in an alphabetical order.

Relevance
This manual applies to the following Samsung network software releases:

Technology Software Release

LTE Package 2.6.1

© SAMSUNG Electronics Co., Ltd. I


INTRODUCTION

Revision History
VERSION DATE OF ISSUE REMARKS

1.0 03. 2013. First Version

II © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description

TABLE OF CONTENTS

INTRODUCTION I

Purpose ...................................................................................................................................................... I
Audience ..................................................................................................................................................... I
Document Content and Organization ....................................................................................................... I
Relevance ................................................................................................................................................... I
Revision History ........................................................................................................................................ II

CHAPTER 1. Overview 1-1

1.1 Description of entries ............................................................................................................ 1-1

1.2 Main body of parameter entries ............................................................................................ 1-2

CHAPTER 2. Parameter Description 2-1

2.1 A .............................................................................................................................................. 2-1

2.2 B ............................................................................................................................................ 2-43

2.3 C ............................................................................................................................................ 2-98

2.4 D .......................................................................................................................................... 2-158

2.5 E .......................................................................................................................................... 2-182

2.6 F .......................................................................................................................................... 2-206

2.7 G .......................................................................................................................................... 2-215

2.8 H .......................................................................................................................................... 2-237

2.9 I ............................................................................................................................................ 2-253

2.10 J........................................................................................................................................... 2-289

2.11 K .......................................................................................................................................... 2-289

2.12 L .......................................................................................................................................... 2-290

2.13 M.......................................................................................................................................... 2-294

2.14 N .......................................................................................................................................... 2-377

2.15 O .......................................................................................................................................... 2-401

2.16 P ...........................................................................................................................................2-411

2.17 Q .......................................................................................................................................... 2-460

© SAMSUNG Electronics Co., Ltd. III


TABLE OF CONTENTS

2.18 R........................................................................................................................................... 2-480

2.19 S ........................................................................................................................................... 2-540

2.20 T ........................................................................................................................................... 2-601

2.21 U........................................................................................................................................... 2-652

2.22 V ........................................................................................................................................... 2-667

2.23 W .......................................................................................................................................... 2-669

2.24 X ........................................................................................................................................... 2-670

IV © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description

CHAPTER 1. Overview

1.1 Description of entries


Each parameter is described separately and arranged in alphabetical order.
Entries fall into two parts:
 Header line: Parameter name
 Main body, composed of several fields as mentioned in section 1.2.

Each parameter is described in detail to show how -


 To enable or disable a feature.
 To configure the parameter.
 Operator can modify the values of the parameter.

Engineering rule related to each parameter is provided and corresponding range unit
of the parameter is also available.
If any caution need to take care pertaining to any parameter or during its configura
tion is also mentioned in the document for each parameter.

Chapter 2 contains parameters arranged in an alphabetical order.

© SAMSUNG Electronics Co., Ltd. 1-1


CHAPTER 1. Overview

1.2 Main body of parameter entries


The main body contains up below fields:
 Parameter Name
 Description: parameter definition
 Object class & hierarchy: object name(s) in which the parameter is defined
 Type: parameter type.
 Data Type: int, byte, word, enum
 Unit: unit in which the parameter value is expressed, such as seconds, minutes, and
dBm
 Range: displayed in square brackets and the unit if any
 Read/Write: Readable (READ) or writable (READ_WRITE)
 Default value: Default value for the parameter
 Rec. Value: Recommendation
 Commands: Related commands to access the parameter.
 Engineering Rules: Rules for modifying the parameter value based on different
Conditions
 Caution/Note: Checks/conditions/remarks/notes, wherever applicable
 Delta: Indicates if there is a change from previous Software package
 Real time change: Can be modified at real-time or not
 Need to Reset: Any Hardware/board reset needed after parameter value is changed

1-2 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description

CHAPTER 2. Parameter Description

2.1 A
A1_THRESHOLD_RSRP
Parameter name A1_THRESHOLD_RSRP
Description RSRP threshold used for the EUTRA measurement report
triggering condition of Event A1.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-EUTRA-A1CNF, CHG-EUTRA-A1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g.,, handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-1


CHAPTER 2. Parameter Description

A1_THRESHOLD_RSRQ
Parameter name A1_THRESHOLD_RSRQ
Description RSRQ threshold used for the EUTRA measurement report
triggering condition of Event A1.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 32
Rec. Value 32
Commands RTRV-EUTRA-A1CNF, CHG-EUTRA-A1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g.,, Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g.,, handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-2 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

A2_THRESHOLD_RSRP
Parameter name A2_THRESHOLD_RSRP
Description RSRP threshold used for the EUTRA measurement report
triggering condition of Event A2.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-EUTRA-A2CNF, CHG-EUTRA-A2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g.,, handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-3


CHAPTER 2. Parameter Description

A2_THRESHOLD_RSRQ
Parameter name A2_THRESHOLD_RSRQ
Description RSRQ threshold used for the EUTRA measurement report
triggering condition of Event A2.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 32
Rec. Value 32
Commands RTRV-EUTRA-A2CNF, CHG-EUTRA-A2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g.,, handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-4 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

A3_OFFSET
Parameter name A3_OFFSET
Description RSRP threshold used for the EUTRA measurement report
triggering condition of Event A3.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type short
Unit dB
Range -30-30
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-EUTRA-A3CNF, CHG-EUTRA-A3CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g.,, Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-5


CHAPTER 2. Parameter Description

A3_REPORT_ON_LEAVE
Parameter name A3_REPORT_ON_LEAVE
Description Whether to report when an UE satisfies Event A3 leaving condition.
- False: Set the a3ReportOnLeave parameter to False. Even when
an UE satisfies leaving condition, it is not reported (default).
- True: Set the a3ReportOnLeave parameter to True. When an UE
satisfies leaving condition, it is reported.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-EUTRA-A3CNF, CHG-EUTRA-A3CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-6 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

A4_THRESHOLD_RSRP
Parameter name A4_THRESHOLD_RSRP
Description RSRP threshold used for the EUTRA measurement report
triggering condition of Event A4.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-EUTRA-A4CNF, CHG-EUTRA-A4CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-7


CHAPTER 2. Parameter Description

A4_THRESHOLD_RSRQ
Parameter name A4_THRESHOLD_RSRQ
Description RSRQ threshold used for the EUTRA measurement report
triggering condition of Event A4.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 32
Rec. Value 32
Commands RTRV-EUTRA-A4CNF, CHG-EUTRA-A4CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-8 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

A5_THRESHOLD1_RSRP
Parameter name A5_THRESHOLD1_RSRP
Description RSRP threshold1 used for the EUTRA measurement report
triggering condition of Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-EUTRA-A5CNF, CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-9


CHAPTER 2. Parameter Description

A5_THRESHOLD1_RSRQ
Parameter name A5_THRESHOLD1_RSRQ
Description RSRQ threshold1 used for the EUTRA measurement report
triggering condition of Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 32
Rec. Value 32
Commands RTRV-EUTRA-A5CNF, CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-10 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

A5_THRESHOLD2_RSRP
Parameter name A5_THRESHOLD2_RSRP
Description RSRP threshold2 used for the EUTRA measurement report
triggering condition of Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-EUTRA-A5CNF, CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-11


CHAPTER 2. Parameter Description

A5_THRESHOLD2_RSRQ
Parameter name A5_THRESHOLD2_RSRQ
Description RSRQ threshold2 used for the EUTRA measurement report
triggering condition of Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 32
Rec. Value 32
Commands RTRV-EUTRA-A5CNF, CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-12 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACC_CLASS_BAR_TIME_DATA
Parameter name ACC_CLASS_BAR_TIME_DATA
Description Access barring time for a cell in a base station.
A UE does not perform RRC connection configuration until the
T305 timer is elapsed if a random value (from 0 to 1), generated by
the UE, is less than accessProbabilityFactor by assuming the cell
is barred. The T305 timer value is calculated based on (0.7 + 0.6 *
rand) * acBarring time.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_s4/ci_s8/ci_s16/ci_s32/ci_s64/ci_s128/ci_s256/ci_s512
Read/Write READ/WRITE
Default value ci_s512
Rec. Value ci_s512
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-13


CHAPTER 2. Parameter Description

ACC_CLASS_BAR_TIME_MMTELVIDEO
Parameter name ACC_CLASS_BAR_TIME_MMTELVIDEO
Description Access barring time for a cell in a base station.
A UE does not perform RRC connection configuration until the
T305 timer is elapsed if a random value (from 0 to 1), generated by
the UE, is less than accessProbabilityFactor by assuming the cell
is barred. The T305 timer value is calculated based on (0.7 + 0.6 *
rand) * acBarring time.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_s4/ci_s8/ci_s16/ci_s32/ci_s64/ci_s128/ci_s256/ci_s512
Read/Write READ/WRITE
Default value ci_s4
Rec. Value ci_s4
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-14 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACC_CLASS_BAR_TIME_MMTELVOICE
Parameter name ACC_CLASS_BAR_TIME_MMTELVOICE
Description Access barring time for a cell in a base station.
A UE does not perform RRC connection configuration until the
T305 timer is elapsed if a random value (from 0 to 1), generated by
the UE, is less than accessProbabilityFactor by assuming the cell
is barred. The T305 timer value is calculated based on (0.7 + 0.6 *
rand) * acBarring time.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_s4/ci_s8/ci_s16/ci_s32/ci_s64/ci_s128/ci_s256/ci_s512
Read/Write READ/WRITE
Default value ci_s4
Rec. Value ci_s4
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-15


CHAPTER 2. Parameter Description

ACC_CLASS_BAR_TIME_SIGNAL
Parameter name ACC_CLASS_BAR_TIME_SIGNAL
Description Access barring time for a cell in a base station.
A UE does not perform RRC connection configuration until the
T305 timer is elapsed if a random value (from 0 to 1), generated by
the UE, is less than accessProbabilityFactor by assuming the cell
is barred. The T305 timer value is calculated based on (0.7 + 0.6 *
rand) * acBarring time.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_s4/ci_s8/ci_s16/ci_s32/ci_s64/ci_s128/ci_s256/ci_s512
Read/Write READ/WRITE
Default value ci_s512
Rec. Value ci_s512
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-16 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACCESS_BARRING_EMERGENCY_CALL
Parameter name ACCESS_BARRING_EMERGENCY_CALL
Description Whether to use emergency call barring of a cell in a station.
- False: Emergency Call Barring is not used.
- True: Emergency Call Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-17


CHAPTER 2. Parameter Description

ACC_PROB_FAC_DATA
Parameter name ACC_PROB_FAC_DATA
Description Access probability factor of a cell in a station.
A UE can access a cell if a rand value (from 0 to 1), generated by
the UE, is rand lt; accessProbabilityFactor. If not, it cannot access
a cell.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_p00/ci_p05/ci_p10/ci_p15/ci_p20/ci_p25/ci_p30/ci_p40/ci_p50/
ci_p60/ci_p70/ci_p75/ci_p80/ci_p85/ci_p90/ci_p95
Read/Write READ/WRITE
Default value ci_p95
Rec. Value ci_p95
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-18 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACC_PROB_FAC_MMTELVIDEO
Parameter name ACC_PROB_FAC_MMTELVIDEO
Description Access probability factor of a cell in a station.
A UE can access a cell if a rand value (from 0 to 1), generated by
the UE, is rand lt; accessProbabilityFactor. If not, it cannot access
a cell.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_p00/ci_p05/ci_p10/ci_p15/ci_p20/ci_p25/ci_p30/ci_p40/ci_p50/
ci_p60/ci_p70/ci_p75/ci_p80/ci_p85/ci_p90/ci_p95
Read/Write READ/WRITE
Default value ci_p95
Rec. Value ci_p95
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-19


CHAPTER 2. Parameter Description

ACC_PROB_FAC_MMTELVOICE
Parameter name ACC_PROB_FAC_MMTELVOICE
Description Access probability factor of a cell in a station.
A UE can access a cell if a rand value (from 0 to 1), generated by
the UE, is rand lt; accessProbabilityFactor. If not, it cannot access
a cell.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_p00/ci_p05/ci_p10/ci_p15/ci_p20/ci_p25/ci_p30/ci_p40/ci_p50/
ci_p60/ci_p70/ci_p75/ci_p80/ci_p85/ci_p90/ci_p95
Read/Write READ/WRITE
Default value ci_p95
Rec. Value ci_p95
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-20 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACC_PROB_FAC_SIGNAL
Parameter name ACC_PROB_FAC_SIGNAL
Description Access probability factor of a cell in a station.
A UE can access a cell if a rand value (from 0 to 1), generated by
the UE, is rand lt; accessProbabilityFactor. If not, it cannot access
a cell.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range ci_p00/ci_p05/ci_p10/ci_p15/ci_p20/ci_p25/ci_p30/ci_p40/ci_p50/
ci_p60/ci_p70/ci_p75/ci_p80/ci_p85/ci_p90/ci_p95
Read/Write READ/WRITE
Default value ci_p95
Rec. Value ci_p95
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-21


CHAPTER 2. Parameter Description

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use Event A1.
- Inactive: Event A1 is not used.
- Active: Event A1 is used.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-EUTRA-A1CNF, CHG-EUTRA-A1CNF
Engineering rules If this parameter setting is changed, it will affect the measurement
gap while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-22 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use Event A2.
- Inactive: Event A2 is not used.
- Active: Event A2 is used.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-EUTRA-A2CNF, CHG-EUTRA-A2CNF
Engineering rules If this parameter setting is changed, it will affect the measurement
gap while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-23


CHAPTER 2. Parameter Description

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use Event A3.
- Inactive: Event A3 is not used.
- Active: Event A3 is used.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Active
Rec. Value Active
Commands RTRV-EUTRA-A3CNF, CHG-EUTRA-A3CNF
Engineering rules If this parameter setting is changed, it will affect the mobility (e.g.,
handover) while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-24 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use Event A4.
- Inactive: Event A4 is not used.
- Active: Event A4 is used.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-EUTRA-A4CNF, CHG-EUTRA-A4CNF
Engineering rules If this parameter setting is changed, it will affect the mobility (e.g.,
handover) while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-25


CHAPTER 2. Parameter Description

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use Event A5.
- Inactive: Event A5 is not used.
- Active: Event A5 is used.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-EUTRA-A5CNF, CHG-EUTRA-A5CNF
Engineering rules If this parameter setting is changed, it will affect the mobility (e.g.,
handover) while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-26 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use EUTRA periodic report.
- Inactive: EUTRA periodic report is not used.
- Active: EUTRA periodic report is used.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-EUTRA-PRD, CHG-EUTRA-PRD
Engineering rules If this parameter setting is changed, it will affect the SONoperation
(e.g., ANR) while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use GERAN B1 event report.
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-GERAN-B1CNF, CHG-GERAN-B1CNF
Engineering rules If this parameter setting is changed, it will affect the measurement
gap operation while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-27


CHAPTER 2. Parameter Description

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use GERAN B2 event report.
- Inactive: GERAN B2 event report is not used.
- Active: GERAN B2 event report is used.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-GERAN-B2CNF, CHG-GERAN-B2CNF
Engineering rules If this parameter setting is changed, it will affect the measurement
gap operation while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-28 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use GERAN periodic event report .
- Inactive: GERAN periodic event report is not used.
- Active: GERAN periodic event report is used.
Object class & hierarchy PLDGeranPeriodicInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-GERAN-PRD, CHG-GERAN-PRD
Engineering rules If this parameter setting is changed, it will affect the measurement
gap operation while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-29


CHAPTER 2. Parameter Description

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description As the state information of an operational MME, its
ACTIVE_STATE is changed to Inactive if there is a MME that is not
meant to be used among MMEs that have linked S1 setup. The
default is active. If the status is Equip, it is recommended not to
change the status to Inactive.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type word32
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Active
Rec. Value Active
Commands RTRV-MME-CONF, CHG-MME-CONF
Engineering rules - Active: An operator uses MME that has S1 setup.
- Inactive: An operator does not use MME that has S1 setup.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-30 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use UTRA Event B1.
- Inactive: UTRA Event B1 is not used.
- Active: UTRA Event B1 is used.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Active
Rec. Value Active
Commands RTRV-UTRA-B1CNF, CHG-UTRA-B1CNF
Engineering rules If this parameter setting is changed, it will affect the measurement
gap operation while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-31


CHAPTER 2. Parameter Description

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use UTRA Event B2.
- Inactive: UTRA Event B2 is not used.
- Active: UTRA Event B2 is used.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-UTRA-B2CNF, CHG-UTRA-B2CNF
Engineering rules If this parameter setting is changed, it will affect the measurement
gap operation while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-32 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_STATE
Parameter name ACTIVE_STATE
Description Whether to use UTRA periodic report .
- Inactive: UTRA periodic report is not used.
- Active: UTRA periodic report is used.
Object class & hierarchy PLDUtraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range Inactive/Active
Read/Write READ/WRITE
Default value Inactive
Rec. Value Inactive
Commands RTRV-UTRA-PRD, CHG-UTRA-PRD
Engineering rules If this parameter setting is changed, it will affect the measurement
gap operation while the UE is active.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

ACTIVE_UECOUNT
Parameter name ACTIVE_UECOUNT
Description Number of active calls applied to a channel card.
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit UE
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This parameter indicates the Active Call Count currently connected
to the Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-33


CHAPTER 2. Parameter Description

ACTIVE_UECOUNT
Parameter name ACTIVE_UECOUNT
Description Number of active calls applied to a cell.
Object class & hierarchy PLDCellPlmnState
Type Static
Data Type int
Unit UE
Range 0-2147483647
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELLPLMN-STS
Engineering rules This parameter indicates the Active Call Count currently connected
to the Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

ACTIVE_UECOUNT
Parameter name ACTIVE_UECOUNT
Description Number of active calls applied to a cell.
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit UE
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules This parameter indicates the Active Call Count currently connected
to the Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-34 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ACTIVE_UECOUNT
Parameter name ACTIVE_UECOUNT
Description Number of active calls applied to a sub-cell.
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit UE
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules This parameter indicates the Active Call Count currently connected
to the Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

ACTIVE_UECOUNT
Parameter name ACTIVE_UECOUNT
Description Accumulated number of calls applied to all the cells in the system.
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit UE
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules This parameter indicates the Active Call Count currently connected
to the Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-35


CHAPTER 2. Parameter Description

ADD_SPECTRUM_EMISSION
Parameter name ADD_SPECTRUM_EMISSION
Description Additional spectrum emission used by an operational cell.
A UE can reduce power from max. power (3GPP TS 36.101,
6.2.4). This information is broadcasted to the UE via SIB2.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type word32
Unit NA
Range 1-32
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-36 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ADMINISTRATIVE_STATE
Parameter name ADMINISTRATIVE_STATE
Description This parameter changes the X2 Link state to Neighbor eNB.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range locked/unlocked/shuttingDown
Read/Write READ/WRITE
Default value unlocked
Rec. Value unlocked
Commands RTRV-NBR-ENB, CHG-NBR-ENB, CRTE-NBR-ENB, DLT-NBR-ENB
Engineering rules Changes the settings for Unlocked, Shutdown, and Locked.
Unlocked signifies a normal operation of the X2 Link state. Shutdown
signifies the normal execution of the current X2 Handover in
progress, but restricts new X2 Handovers.
Locked signifies restriction of both the current X2 Handover in
progress and the new X2 Handover.
Caution/Note Please note that if the setting is set to Shutdown or Locked, the S1
Handover is executed instead of the X2 Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-37


CHAPTER 2. Parameter Description

ADMINISTRATIVE_STATE
Parameter name ADMINISTRATIVE_STATE
Description Status of MME link.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type word32
Unit NA
Range locked/unlocked/shuttingDown
Read/Write READ/WRITE
Default value unlocked
Rec. Value unlocked
Commands RTRV-MME-CONF, CHG-MME-CONF
Engineering rules - locked: The active calls connected to the MME are all dropped
and no new call is allowed to be connected to the MME.
- unlocked: Connection to the MME is normal.
- shuttingDown: The active calls connected to the MME are
maintained, but no new call is allowed to be connected to the
MME.
Caution/Note Before selecting Locked option, please note that all the signals for
the corresponding MME become disconnected, if Locked is
selected.
Delta NA
Real time change Yes
Need to reset No

2-38 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ARFCN
Parameter name ARFCN
Description ARFCN of a GERAN neighbor cell located around a base station.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-1023
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN, CHG-NBR-GERAN, CRTE-NBR-GERAN,
DLT-NBR-GERAN
Engineering rules This parameter indicates the ARFCN value of the GERAN
Neighbor Cell. Values ranging from 0-1023 can be entered, but the
actual value used in the GERAN network must be entered.
Caution/Note Take precaution so as not to enter the same information you’ve
entered previously. (If all three of the networkColourCode,
baseStationColourCode, and ARFCN information match the
previously entered information, then the system determines it as
repeated entry.)
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-39


CHAPTER 2. Parameter Description

ARFCN_DL
Parameter name ARFCN_DL
Description Downlink ARFCN (Absolute Radio Frequency Channel Number) of
a UTRAN neighbor cell located around a base station.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-16383
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN, CHG-NBR-UTRAN, CRTE-NBR-UTRAN,
DLT-NBR-UTRAN
Engineering rules This parameter indicates the ARFCN DL value of the UTRAN
Neighboring Cell. Values from 0 to 16,383 can be entered.
Please note that if this parameter is used, then the exact value
used by the actual UTRAN network must be entered.
Caution/Note Be sure not to enter the same value that was previously registered.
(If the physCellID and ARFCN DL are identical, the system
determines the entry to be a repeated entry).
Delta NA
Real time change Yes
Need to reset No

2-40 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ARFCN_UL
Parameter name ARFCN_UL
Description Uplink ARFCN (Absolute Radio Frequency Channel Number) of a
UTRAN neighbor cell located around a base station.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-16383
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN, CHG-NBR-UTRAN, CRTE-NBR-UTRAN,
DLT-NBR-UTRAN
Engineering rules This parameter indicates the ARFCN UL value of the UTRAN
Neighboring Cell. Values from 0 to 16,383 can be entered.
Please note that if this parameter is used, then the exact value
used by the actual UTRAN network must be entered.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-41


CHAPTER 2. Parameter Description

AUTO_RECOVERY_METHOD
Parameter name AUTO_RECOVERY_METHOD
Description Method of automatic recovery.
Object class & hierarchy PLDDiagCallConf
Type Static
Data Type word32
Unit NA
Range CELL_RELEASE/DSP_RESET_ONLY
/RU_RESET_ONLY/DSP_RU_RESET
Read/Write READ/WRITE
Default value CELL_RELEASE
Rec. Value CELL_RELEASE
Commands RTRV-DIAG-CONF, CHG-DIAG-CONF
Engineering rules This procedure is for engaging auto recovery if alarm is triggered.
- CELL_RELEASE: Releases the Cell and engages recovery.
- DSP_RESET_ONLY: Resets the DSP and engages recovery.
- RU_RESET_ONLY: Resets the RU and engages recovery.
- DSP_RU_RESET: Resets the DSP and the RU and engages
recovery.
Caution/Note The Auto Recovery is the procedure of resetting the corresponding
Cell or the Base Station. Please note that the all the signals for the
corresponding Cell or the Base Station become disconnected, if
Reset option is selected.
Delta NA
Real time change Yes
Need to reset No

2-42 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.2 B
B1_THRESHOLD_GERAN
Parameter name B1_THRESHOLD_GERAN
Description Threshold1 of GERAN B1 event report.
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-63
Read/Write READ/WRITE
Default value 60
Rec. Value 60
Commands RTRV-GERAN-B1CNF, CHG-GERAN-B1CNF
Engineering rules The actual value is (parameter-110) dBm.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

B1_THRESHOLD_UTRA_EC_NO
Parameter name B1_THRESHOLD_UTRA_EC_NO
Description UTRA EcNO threshold used for the Inter-RAT measurement report
triggering condition of UTRA Event B1.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-49
Read/Write READ/WRITE
Default value 20
Rec. Value 20
Commands RTRV-UTRA-B1CNF, CHG-UTRA-B1CNF
Engineering rules It’s the EcNO threshold used for the UTRA B1 Event report trigger
and used the when the measQuantityUtra equals EcNO.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-43


CHAPTER 2. Parameter Description

B1_THRESHOLD_UTRA_RSCP
Parameter name B1_THRESHOLD_UTRA_RSCP
Description UTRA RSCP threshold used for the Inter-RAT measurement report
triggering condition of UTRA Event B1.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type short
Unit NA
Range -5-91
Read/Write READ/WRITE
Default value 80
Rec. Value 80
Commands RTRV-UTRA-B1CNF, CHG-UTRA-B1CNF
Engineering rules It’s the RSCP threshold used for the UTRA B1 Event report trigger
and used the when the measQuantityUtra equals RSCP.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

B2_THRESHOLD1_RSRP
Parameter name B2_THRESHOLD1_RSRP
Description RSRP threshold of GERAN B2 event report.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 70
Rec. Value 70
Commands RTRV-GERAN-B2CNF, CHG-GERAN-B2CNF
Engineering rules The corresponding parameter indicates the RSRP Threshold of the
GERAN B2 Threshold1 (ThresholdEUTRA).
Caution/Note The corresponding parameter is used when the
triggerQuantityEutra is set to RSRP.
Delta NA
Real time change Yes
Need to reset No

2-44 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

B2_THRESHOLD1_RSRP
Parameter name B2_THRESHOLD1_RSRP
Description RSRP threshold1 used for the EUTRA measurement report
triggering condition of UTRA Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-97
Read/Write READ/WRITE
Default value 70
Rec. Value 70
Commands RTRV-UTRA-B2CNF, CHG-UTRA-B2CNF
Engineering rules It’s the RSCP threshold used for the Eutra Measurement report
trigger of UTRA B2 Event and used the when the trigQuan equals
RSCP.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

B2_THRESHOLD1_RSRQ
Parameter name B2_THRESHOLD1_RSRQ
Description RSRQ threshold of GERAN B2 Event Report.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-GERAN-B2CNF, CHG-GERAN-B2CNF
Engineering rules The corresponding parameter indicates the RSRQ Threshold of the
GERAN B2 Threshold1 (ThresholdEUTRA).
Caution/Note The corresponding parameter is used when the
triggerQuantityEutra is set to RSRQ.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-45


CHAPTER 2. Parameter Description

B2_THRESHOLD1_RSRQ
Parameter name B2_THRESHOLD1_RSRQ
Description RSRQ threshold1 used for the EUTRA measurement report
triggering condition of UTRA Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit dB
Range 0-34
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-UTRA-B2CNF, CHG-UTRA-B2CNF
Engineering rules It’s the RSRQ threshold used for the Eutra Measurement report
trigger of UTRA B2 Event and used the when the trigQuan equals
RSRQ.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

B2_THRESHOLD2_GERAN
Parameter name B2_THRESHOLD2_GERAN
Description Threshold of GERAN Event B2 report.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit dBm
Range 0-63
Read/Write READ/WRITE
Default value 60
Rec. Value 60
Commands RTRV-GERAN-B2CNF, CHG-GERAN-B2CNF
Engineering rules It is a Threshold for the GERAN B2 Event report trigger. It indicates
the Threshold value for GREAN Measurement. The actual value is
(parameter-110) dBm.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-46 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

B2_THRESHOLD2_UTRA_EC_NO
Parameter name B2_THRESHOLD2_UTRA_EC_NO
Description UTRA EcNO threshold2 used for the Inter-RAT UTRA
measurement report triggering condition of UTRA Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-49
Read/Write READ/WRITE
Default value 20
Rec. Value 20
Commands RTRV-UTRA-B2CNF, CHG-UTRA-B2CNF
Engineering rules The condition/value is used if measQuantityUtra equals EcNO.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

B2_THRESHOLD2_UTRA_RSCP
Parameter name B2_THRESHOLD2_UTRA_RSCP
Description UTRA RSCP threshold2 used for the Inter-RAT UTRA
measurement report triggering condition of UTRA Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type short
Unit NA
Range -5-91
Read/Write READ/WRITE
Default value 80
Rec. Value 80
Commands RTRV-UTRA-B2CNF, CHG-UTRA-B2CNF
Engineering rules The condition/value is used if measQuantityUtra equals RSCP.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-47


CHAPTER 2. Parameter Description

BAND_INDICATOR
Parameter name BAND_INDICATOR
Description Band indicator of a GERAN neighbor cell around a base station.
- dcs1800: Indicate DCS 1800 band.
- dcs1900: Indicate PCS 1900 band.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range ci_dcs1800/ci_pcs1900
Read/Write READ/WRITE
Default value ci_dcs1800
Rec. Value ci_dcs1800
Commands RTRV-NBR-GERAN, CHG-NBR-GERAN, CRTE-NBR-GERAN,
DLT-NBR-GERAN
Engineering rules The BandIndicator value included in measObjectGERAN can either
be DCS1800 or PCS1900. If the ARFCN has no relation with either
of the two bands, then the BandIndicator value is meaningless.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-48 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAND_INDICATOR
Parameter name BAND_INDICATOR
Description Band indicator of GERAN FA object.
- dcs1800: Indicate DCS 1800 band.
- dcs1900: Indicate PCS 1900 band.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range ci_dcs1800/ci_pcs1900
Read/Write READ/WRITE
Default value ci_dcs1800
Rec. Value ci_dcs1800
Commands RTRV-GERAN-FA, CHG-GERAN-FA
Engineering rules It indicates the GERAN Band Indicator to which the corresponding
GERAN FA belongs to.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-49


CHAPTER 2. Parameter Description

BAND_INDICATOR
Parameter name BAND_INDICATOR
Description Designates the Target Band during Idle Mode Load Distribution.
Object class & hierarchy PLDIdleModeLbInfoFunc
Type Static
Data Type word16
Unit NA
Range 1-64
Read/Write READ/WRITE
Default value 2
Rec. Value 2
Commands RTRV-IDLELB-INFO, CHG-IDLELB-INFO
Engineering rules This value designates the Band information that is to be included in
the IdleModeControlInfo IE during Idle Mode Load Distribution.
When entering this setting, enter the information used by the
neighboring LTE network.
Caution/Note Enter the actual information in use by the neighboring LTE network.
Delta NA
Real time change Yes
Need to reset No

2-50 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BANDWIDTH_DL
Parameter name BANDWIDTH_DL
Description Downlink bandwidth information of a E-UTRAN neighbor cell
around a base station.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range ci_SystemBandwidth_n6(0)/ci_SystemBandwidth_n15(1)/
ci_SystemBandwidth_n25(2)/ci_SystemBandwidth_n50(3)/
ci_SystemBandwidth_n75(4)/ci_SystemBandwidth_n100(5)
Read/Write READ/WRITE
Default value ci_SystemBandwidth_n25(2)
Rec. Value ci_SystemBandwidth_n25(2)
Commands RTRV-NBR-EUTRAN, CHG-NBR-EUTRAN, CRTE-NBR-EUTRAN,
DLT-NBR-EUTRAN
Engineering rules Each of the following downlink transmission bandwidth parameter
values indicates:
- ci_SystemBandwidth_n6: 6 RBs are used.
- ci_SystemBandwidth_n15: 15 RBs are used.
- ci_SystemBandwidth_n25: 25 RBs are used.
- ci_SystemBandwidth_n50: 50 RBs are used.
- ci_SystemBandwidth_n75: 75 RBs are used.
- ci_SystemBandwidth_n100: 100 RBs are used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-51


CHAPTER 2. Parameter Description

BANDWIDTH_UL
Parameter name BANDWIDTH_UL
Description Uplink bandwidth information of a E-UTRAN neighbor cell around a
base station.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range ci_SystemBandwidth_n6(0)/ci_SystemBandwidth_n15(1)/
ci_SystemBandwidth_n25(2)/ci_SystemBandwidth_n50(3)/
ci_SystemBandwidth_n75(4)/ci_SystemBandwidth_n100(5)
Read/Write READ/WRITE
Default value ci_SystemBandwidth_n25(2)
Rec. Value ci_SystemBandwidth_n25(2)
Commands RTRV-NBR-EUTRAN, CHG-NBR-EUTRAN, CRTE-NBR-EUTRAN,
DLT-NBR-EUTRAN
Engineering rules Each of the following uplink transmission bandwidth parameter
values indicates:
- ci_SystemBandwidth_n6: 6 RBs are used.
- ci_SystemBandwidth_n15: 15 RBs are used.
- ci_SystemBandwidth_n25: 25 RBs are used.
- ci_SystemBandwidth_n50: 50 RBs are used.
- ci_SystemBandwidth_n75: 75 RBs are used.
- ci_SystemBandwidth_n100: 100 RBs are used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-52 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC11_DATA
Parameter name BAR_AC11_DATA
Description Whether to use barring data for AC 11 (Home PLMN only if the
EHPLMN list is not present or any EHPLMN) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-53


CHAPTER 2. Parameter Description

BAR_AC11_MMTELVIDEO
Parameter name BAR_AC11_MMTELVIDEO
Description Whether to use barring data for AC 11 (Home PLMN only if the
EHPLMN list is not present or any EHPLMN) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-54 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC11_MMTELVOICE
Parameter name BAR_AC11_MMTELVOICE
Description Whether to use barring data for AC 11 (Home PLMN only if the
EHPLMN list is not present or any EHPLMN) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-55


CHAPTER 2. Parameter Description

BAR_AC11_SIGNAL
Parameter name BAR_AC11_SIGNAL
Description Whether to use barring for AC 11 (Home PLMN only if the
EHPLMN list is not present or any EHPLMN) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-56 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC12_DATA
Parameter name BAR_AC12_DATA
Description Whether to use barring data for AC 12 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-57


CHAPTER 2. Parameter Description

BAR_AC12_MMTELVIDEO
Parameter name BAR_AC12_MMTELVIDEO
Description Whether to use barring data for AC 12 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-58 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC12_MMTELVOICE
Parameter name BAR_AC12_MMTELVOICE
Description Whether to use barring data for AC 12 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-59


CHAPTER 2. Parameter Description

BAR_AC12_SIGNAL
Parameter name BAR_AC12_SIGNAL
Description Whether to use barring for AC 12 (Home PLMN and visited PLMNs
of home country only. For this purpose the home country is defined
as the country of the MCC part of the IMSI) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-60 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC13_DATA
Parameter name BAR_AC13_DATA
Description Whether to use barring data for AC 13 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-61


CHAPTER 2. Parameter Description

BAR_AC13_MMTELVIDEO
Parameter name BAR_AC13_MMTELVIDEO
Description Whether to use barring data for AC 13 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-62 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC13_MMTELVOICE
Parameter name BAR_AC13_MMTELVOICE
Description Whether to use barring data for AC 13 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-63


CHAPTER 2. Parameter Description

BAR_AC13_SIGNAL
Parameter name BAR_AC13_SIGNAL
Description Whether to use barring for AC 13 (Home PLMN and visited PLMNs
of home country only. For this purpose the home country is defined
as the country of the MCC part of the IMSI) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-64 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC14_DATA
Parameter name BAR_AC14_DATA
Description Whether to use barring data for AC 14 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-65


CHAPTER 2. Parameter Description

BAR_AC14_MMTELVIDEO
Parameter name BAR_AC14_MMTELVIDEO
Description Whether to use barring data for AC 14 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-66 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC14_MMTELVOICE
Parameter name BAR_AC14_MMTELVOICE
Description Whether to use barring data for AC 14 (Home PLMN and visited
PLMNs of home country only. For this purpose the home country is
defined as the country of the MCC part of the IMSI) of a cell in a
base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-67


CHAPTER 2. Parameter Description

BAR_AC14_SIGNAL
Parameter name BAR_AC14_SIGNAL
Description Whether to use barring for AC 14 (Home PLMN and visited PLMNs
of home country only. For this purpose the home country is defined
as the country of the MCC part of the IMSI) of a cell in a base
station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-68 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC15_DATA
Parameter name BAR_AC15_DATA
Description Whether to use barring for AC15 of a cell in a base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-69


CHAPTER 2. Parameter Description

BAR_AC15_MMTELVIDEO
Parameter name BAR_AC15_MMTELVIDEO
Description Whether to use barring for AC15 of a cell in a base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

BAR_AC15_MMTELVOICE
Parameter name BAR_AC15_MMTELVOICE
Description Whether to use barring for AC15 of a cell in a base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-70 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BAR_AC15_SIGNAL
Parameter name BAR_AC15_SIGNAL
Description Whether to use barring for AC15 of a cell in a base station.
- False: Barring is not used.
- True: Barring is used.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-71


CHAPTER 2. Parameter Description

BARRING_CTR_USAGE
Parameter name BARRING_CTR_USAGE
Description How to set up the ac-BarringInfo parameter of SIB2.
- barringOff: Barring control parameter is not used.
- manualCtrl: Barring control is used manually.
- cpuStatusCtrl: Barring control is used depending on CPU
overload.
Object class & hierarchy PLDCellAccessInfoLogic
Type Static
Data Type word32
Unit NA
Range barringOff/manualCtrl/cpuStatusCtrl
Read/Write READ/WRITE
Default value cpuStatusCtrl
Rec. Value cpuStatusCtrl
Commands RTRV-CELL-ACS, CHG-CELL-ACS
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-72 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BARRING_DATA_USAGE
Parameter name BARRING_DATA_USAGE
Description Whether to use ac-BarringforMO-Data of a cell in a base station.
- CI_no_use: ac-BarringforMO-Data is not used. A UE can access
a cell upon service request.
- CI_use: ac-BarringforMO-Data is used. A UE controls access to a
cell depending on access barring data parameter upon service
request.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write -
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-73


CHAPTER 2. Parameter Description

BARRING_MMTELVIDEO_USAGE
Parameter name BARRING_MMTELVIDEO_USAGE
Description Whether to use ac-ssac-BarringForMMTEL-Voice of a cell in a
base station.
- CI_no_use: ssac-BarringForMMTEL-Voice is not used. A UE can
access a cell upon service request.
- CI_use: ssac-BarringForMMTEL-Voice is used. A UE controls
access to a cell depending on access barring data parameter
upon service request.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-74 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BARRING_MMTELVOICE_USAGE
Parameter name BARRING_MMTELVOICE_USAGE
Description Whether to use ssac-BarringForMMTEL-Voice of a cell in a base
station.
- CI_no_use: ssac-BarringForMMTEL-Voice is not used. A UE can
access a cell upon service request.
- CI_use: ssac-BarringForMMTEL-Voice is used. A UE controls
access to a cell depending on access barring data parameter
upon service request.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-75


CHAPTER 2. Parameter Description

BARRING_SIGNAL_USAGE
Parameter name BARRING_SIGNAL_USAGE
Description Whether to use ac-BarringforMO-Signaling of a cell in a base
station.
- CI_no_use: ac-BarringforMO-Signaling is not used. A UE can
access a cell during attachment.
- CI_use: ac-BarringforMO-Signaling is used. A UE controls access
to a cell depending on access barring data parameter during
attachment.
Object class & hierarchy PLDBarringParam
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-76 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BASE_STATION_COLOUR_CODE
Parameter name BASE_STATION_COLOUR_CODE
Description Base station colour code of GERAN neighbor cell around a base
station.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type Byte
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN, CHG-NBR-GERAN, CRTE-NBR-GERAN,
DLT-NBR-GERAN
Engineering rules Indicates the Base station colour code of the neighboring GERAN
Cell. The codes range from 0 to 7 and must be entered in decimal
format. The Base station colour code of the GERAN Neighbor Cell
must be entered accurately.
Caution/Note Enter the correct code. It must not repeat a previously entered
code.
(If all three of the baseStationColourCode, networkColourCode,
and ARFCN information match previously entered information, the
system will deem it to be a repeated entry.)
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-77


CHAPTER 2. Parameter Description

BH_BW_CAC_DL_THRESH_FOR_EMER_HO
Parameter name BH_BW_CAC_DL_THRESH_FOR_EMER_HO
Description This is the percentage of downlink backhaul bandwidth that can be
allocated to each QCI (QoS Class Identifier) for emergency call
and handover call. If the downlink usage exceeds the entered
parameter value when either an emergency call or handover call is
requested, the Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDQciBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-BHBW-QCI, CHG-BHBW-QCI
Engineering rules This is the downlink threshold value when Backhaul CAC for
Emergency handover call is executed and the bhBwCACOption is
either 0 or 2. It is applied only to the Handover call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-78 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BH_BW_CAC_DL_THRESH_FOR_EMER_HO
Parameter name BH_BW_CAC_DL_THRESH_FOR_EMER_HO
Description This is the percentage of downlink backhaul bandwidth that can be
allocated to each service group for emergency call and handover
call. If the downlink usage exceeds the entered parameter value
when either an emergency call or handover call is requested, the
Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDSvcGrpBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-BHBW-SVCGR, CHG-BHBW-SVCGR
Engineering rules This is the downlink threshold value when Backhaul CAC for
Emergency handover call is executed and the bhBwCACOption is
either 0 or 2. It is applied only to the Handover call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-79


CHAPTER 2. Parameter Description

BH_BW_CAC_DL_THRESH_FOR_NORMAL
Parameter name BH_BW_CAC_DL_THRESH_FOR_NORMAL
Description This is the percentage of downlink backhaul bandwidth that can be
allocated to each QCI (QoS Class Identifier) for a Normal call. If the
downlink usage exceeds the entered parameter value when a
normal call is requested, the Backhaul Bandwidth CAC Fail is
generated.
Object class & hierarchy PLDQciBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 30
Rec. Value 30
Commands RTRV-BHBW-QCI, CHG-BHBW-QCI
Engineering rules This is the downlink threshold value when Backhaul CAC for
normal call is executed and the bhBwCACOption is either 0 or 2.
It is applied only to the Normal call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-80 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BH_BW_CAC_DL_THRESH_FOR_NORMAL
Parameter name BH_BW_CAC_DL_THRESH_FOR_NORMAL
Description This is the percentage of downlink backhaul bandwidth that can be
allocated to each service group for a Normal Call. If the downlink
usage exceeds the entered parameter value when a normal call is
requested, the Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDSvcGrpBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 30
Rec. Value 30
Commands RTRV-BHBW-SVCGR, CHG-BHBW-SVCGR
Engineering rules This is the downlink threshold value when Backhaul CAC for
normal call is executed and the bhBwCACOption is either 0 or 2.
It is applied only to the Normal call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-81


CHAPTER 2. Parameter Description

BH_BW_CAC_OPTION
Parameter name BH_BW_CAC_OPTION
Description This is the parameter that determines the Backhaul CAC policy
used when backhaul based CAC (Call Admission Control) is
performed per cell.
- bhBwCac_QCI_only: QoS based CAC.
- bhBwCac_ServiceGroup_only: Service group based CAC.
- bhBwCac_Both_QCI_ServiceGroup: QoS amp; Service group
based CAC.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range bhBwCac_QCI_only/bhBwCac_ServiceGroup_only/
bhBwCac_Both_QCI_ServiceGroup
Read/Write READ/WRITE
Default value bhBwCac_ServiceGroup_only
Rec. Value bhBwCac_ServiceGroup_only
Commands RTRV-CELL-CAC, CHG-CELL-CAC
Engineering rules If the parameter is 0, QoS based CAC is applied. If the parameter
is 1, then the Service Group based CAC is applied. If the
parameter is 2, both the Qos and Service Group based CAC’s are
applied.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-82 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BH_BW_CAC_UL_THRESH_FOR_EMER_HO
Parameter name BH_BW_CAC_UL_THRESH_FOR_EMER_HO
Description This is the percentage of uplink backhaul bandwidth that can be
allocated to each QCI (QoS Class Identifier) for emergency call
and handover call. If the uplink usage exceeds the entered
parameter value when either an emergency call or handover call is
requested, the Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDQciBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-BHBW-QCI, CHG-BHBW-QCI
Engineering rules This is the uplink threshold value when Backhaul CAC for
Emergency handover call is executed and the bhBwCACOption is
either 0 or 2. It is applied only to the Handover call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-83


CHAPTER 2. Parameter Description

BH_BW_CAC_UL_THRESH_FOR_EMER_HO
Parameter name BH_BW_CAC_UL_THRESH_FOR_EMER_HO
Description This is the percentage of uplink backhaul bandwidth that can be
allocated to each service group for emergency call and handover
call.. If the uplink usage exceeds the entered parameter value
when either an emergency call or handover call is requested, the
Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDSvcGrpBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 35
Rec. Value 35
Commands RTRV-BHBW-SVCGR, CHG-BHBW-SVCGR
Engineering rules This is the uplink threshold value when Backhaul CAC for
Emergency handover call is executed and the bhBwCACOption is
either 0 or 2. It is applied only to the Handover call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-84 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BH_BW_CAC_UL_THRESH_FOR_NORMAL
Parameter name BH_BW_CAC_UL_THRESH_FOR_NORMAL
Description This is the percentage of uplink backhaul bandwidth that can be
allocated to each QCI (QoS Class Identifier) for a normal call. If the
uplink usage amount the entered parameter value when a normal
call is requested, the Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDQciBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 30
Rec. Value 30
Commands RTRV-BHBW-QCI, CHG-BHBW-QCI
Engineering rules This is the uplink threshold value when Backhaul CAC for Normal
call is executed and the bhBwCACOption is either 0 or 2.
It is applied only to the Normal call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-85


CHAPTER 2. Parameter Description

BH_BW_CAC_UL_THRESH_FOR_NORMAL
Parameter name BH_BW_CAC_UL_THRESH_FOR_NORMAL
Description This is the percentage of uplink backhaul bandwidth that can be
allocated to each service group for Normal Call. If the uplink usage
amount the entered parameter value when a normal call is
requested, the Backhaul Bandwidth CAC Fail is generated.
Object class & hierarchy PLDSvcGrpBhBwInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 30
Rec. Value 30
Commands RTRV-BHBW-SVCGR, CHG-BHBW-SVCGR
Engineering rules This is the uplink threshold value when Backhaul CAC for Normal
call is executed and the bhBwCACOption is either 0 or 2.
It is applied only to the Normal call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-86 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BH_BW_CAC_USAGE
Parameter name BH_BW_CAC_USAGE
Description This is the parameter that determines whether or not to execute
Backhaul bandwidth based CAC per cell.
- CI_no_use: Does not perform backhaul bandwidth based CAC.
- CI_use: Performs backhaul bandwidth based CAC.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-CELL-CAC, CHG-CELL-CAC
Engineering rules If the parameter is set to CI_no_use, then Backhaul CAC is not
executed. If the parameter is set to CI_use, then Backhaul CAC is
executed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-87


CHAPTER 2. Parameter Description

BH_LINK_CAPACITY[Kbps]
Parameter name BH_LINK_CAPACITY[Kbps]
Description Total backhaul link capacity of a base station
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type word32
Unit Kbps
Range 0-10000000
Read/Write READ/WRITE
Default value 1000000
Rec. Value 1000000
Commands RTRV-ENB-INF, CHG-ENB-INF
Engineering rules Indicates the maximum backhaul capacity. Supports up to 0-10
Gigabytes, and the default value is 1 Gigabyte.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-88 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BH_SERVICE_GROUP
Parameter name BH_SERVICE_GROUP
Description Service group of QCI (QoS Class Identifier). The entered
parameter value is used for backhaul CAC (Call Admission
Control).
- voipService: The QCI uses VoIP (voice over Internet Protocol)
service.
- videoService: The QCI uses video service.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range voipService/videoService
Read/Write READ/WRITE
Default value voipService
Rec. Value voipService
Commands RTRV-QCI-VAL, CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-89


CHAPTER 2. Parameter Description

BLACK_LIST_IDX
Parameter name BLACK_LIST_IDX
Description Index information of a black list cell.
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-127
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-BLACK-LIST, CHG-BLACK-LIST, CRTE-BLACK-LIST,
DLT-BLACK-LIST
Engineering rules -
Caution/Note This Index value is required to execute the Search/Change/Create/
Delete commands. If the Index value is not entered when
searching, all EQUIP status information is displayed.
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-90 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BLIND_CCOSUPPORT
Parameter name BLIND_CCOSUPPORT
Description Whether to support blind CCO during GERAN interworking.
- False: Blind CCO is not supported.
- True: Blind CCO is supported.
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-INTERWORKING, CHG-GERAN-INTERWORKING,
RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules The corresponding parameter indicates whether GERAN Blind CCO
is supported or not.
Caution/Note If the parameter is set to not supported, then Blind CCO is not
executed even though Blind CCO is selected in accordance with
priority order. Instead, it determines the synchronized process
commencing with the next order of priority.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-91


CHAPTER 2. Parameter Description

BLIND_PRIORITY0
Parameter name BLIND_PRIORITY0
Description Indicates the first priority of blind type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value enhancedRedirection
Rec. Value enhancedRedirection
Commands RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules This parameter indicates the priority order for the Blind based
GERAN interworking process, excluding PS-HO. It can be specified
in 4 priorities from BlindPriority0 to BlindPriority3, with BlindPriority0
having the highest priority.
Caution/Note In case of GERAN interworking, PS-HO has the highest priority.
If PS-HO is not possible, then the interworking process is
determined based on a preset priority order.
Delta NA
Real time change Yes
Need to reset No

2-92 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BLIND_PRIORITY1
Parameter name BLIND_PRIORITY1
Description Indicates the 2nd priority of blind type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value ccoWithNacc
Rec. Value ccoWithNacc
Commands RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules This parameter indicates the priority order for the Blind based
GERAN interworking process, excluding PS-HO. It can be specified
in 4 priorities from BlindPriority0 to BlindPriority3, with BlindPriority0
having the highest priority.
Caution/Note In case of GERAN interworking, PS-HO has the highest priority.
If PS-HO is not possible, then the interworking process is
determined based on a preset priority order.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-93


CHAPTER 2. Parameter Description

BLIND_PRIORITY2
Parameter name BLIND_PRIORITY2
Description Indicates the 2nd priority of blind type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value ccoWithOutNacc
Rec. Value ccoWithOutNacc
Commands RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules This parameter indicates the priority order for the Blind based
GERAN interworking process, excluding PS-HO. It can be specified
in 4 priorities from BlindPriority0 to BlindPriority3, with BlindPriority0
having the highest priority.
Caution/Note In case of GERAN interworking, PS-HO has the highest priority.
If PS-HO is not possible, then the interworking process is
determined based on a preset priority order.
Delta NA
Real time change Yes
Need to reset No

2-94 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BLIND_PRIORITY3
Parameter name BLIND_PRIORITY3
Description Indicates the 4th priority of blind type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value geranRedirection
Rec. Value geranRedirection
Commands RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules This parameter indicates the priority order for the Blind based
GERAN interworking process, excluding PS-HO. It can be specified
in 4 priorities from BlindPriority0 to BlindPriority3, with BlindPriority0
having the highest priority.
Caution/Note In case of GERAN interworking, PS-HO has the highest priority.
If PS-HO is not possible, then the interworking process is
determined based on a preset priority order.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-95


CHAPTER 2. Parameter Description

BLIND_REDIR_SUPPORT
Parameter name BLIND_REDIR_SUPPORT
Description Whether to support blind redirection during GERAN interworking.
- False: Blind Redirection not support
- True: Blind Redirection support
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules This parameter indicates whether GERAN Blind Redirection is
supported or not.
Caution/Note If the parameter is set to False, then Blind Redirection is not
executed even though Blind Redirection is selected in accordance
with the priority order. Instead, it determines the synchronized
process commencing with the next order of priority.
Delta NA
Real time change Yes
Need to reset No

2-96 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

BUFFERING_TIME
Parameter name BUFFERING_TIME
Description An eNB stores CSL data in the eNB memory for a certain time to
reduce network load. This is called buffering time.
If the buffering time is set to 10, the CSL data in the memory is
transmitted to the CSL server 10 secs after it is generated.
However, the CSL data is immediately transmitted to the CSL
server if 10 CSL data is saved in the memory before 10 seconds
have elapsed.
Object class & hierarchy PLDCslInfo
Type Static
Data Type int
Unit sec
Range 5-60
Read/Write READ/WRITE
Default value 5
Rec. Value 5
Commands RTRV-CSL-INF, CHG-CSL-INF
Engineering rules If the buffering time is too short (e.g.,, 1 second), overload may
occur in the LSM.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-97


CHAPTER 2. Parameter Description

2.3 C
CALL_CAC_THRESH_FOR_EMER_HO
Parameter name CALL_CAC_THRESH_FOR_EMER_HO
Description Acceptable percentage for emergency calls and handover calls.
If the number of connected calls exceeds ‘MAX_CALL_COUNT *
CALL_CAC_THRESH_FOR_EMER_HO’, the Capacity based CAC
Fail is generated when a normal call is requested.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-CELL-CAC, CHG-CELL-CAC
Engineering rules Max call count * callCACThreshForEmerHo is calculated to
execute the CAC for the Emergency call in Cell unit.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-98 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CALL_CAC_THRESH_FOR_EMER_HO
Parameter name CALL_CAC_THRESH_FOR_EMER_HO
Description Acceptable percentage for emergency calls and handover calls.
If the number of connected calls exceeds ‘MAX_ENB_CALL_
COUNT * CALL_CAC_THRESH_FOR_EMER_HO’, the Capacity
based CAC Fail is generated when a normal call is requested.
Object class & hierarchy PLDEnbCacInfoFunc
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-ENB-CAC, CHG-ENB-CAC
Engineering rules Max call count * callCACThreshForEmerHo is calculated to
execute the CAC for the Emergency call in Enb unit.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-99


CHAPTER 2. Parameter Description

CALL_CAC_THRESH_FOR_EMER_HO
Parameter name CALL_CAC_THRESH_FOR_EMER_HO
Description Acceptable percentage for emergency calls and handover calls.
If the number of connected calls exceeds ‘MAX_CALL_COUNT *
CALL_CAC_THRESH_FOR_EMER_HO’, the Capacity based CAC
Fail is generated when a normal call is requested.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-SVR-CAC, CHG-SVR-CAC
Engineering rules Max call count * callCACThreshForEmerHo is calculated to
execute the CAC for the Emergency call in Server unit.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-100 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CALL_CAC_THRESH_FOR_NORMAL
Parameter name CALL_CAC_THRESH_FOR_NORMAL
Description Acceptable percentage for normal calls. If the number of connected
calls exceeds ‘MAX_CALL_COUNT * CALL_CAC_THRESH_
FOR_NORMAL’ when a normal call is requested, the Capacity
based CAC Fail is generated.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 90
Rec. Value 90
Commands RTRV-CELL-CAC, CHG-CELL-CAC
Engineering rules Max call count * callCACThreshForNormal is calculated to execute
the CAC for the Normal call in Cell unit.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-101


CHAPTER 2. Parameter Description

CALL_CAC_THRESH_FOR_NORMAL
Parameter name CALL_CAC_THRESH_FOR_NORMAL
Description Acceptable percentage for normal calls. If the number of connected
calls exceeds ‘MAX_ENB_CALL_COUNT * CALL_CAC_THRESH_
FOR_NORMAL’ when a normal call is requested, the Capacity
based CAC Fail is generated.
Object class & hierarchy PLDEnbCacInfoFunc
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 90
Rec. Value 90
Commands RTRV-ENB-CAC, CHG-ENB-CAC
Engineering rules Max call count * callCACThreshForNormal is calculated to execute
the CAC for the Normal call in eNB unit.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-102 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CALL_CAC_THRESH_FOR_NORMAL
Parameter name CALL_CAC_THRESH_FOR_NORMAL
Description Acceptable percentage for normal calls. If the number of connected
calls exceeds ‘MAX_CALL_COUNT * CALL_CAC_THRESH_
FOR_NORMAL’ when a normal call is requested, the Capacity
based CAC Fail is generated.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 90
Rec. Value 90
Commands RTRV-SVR-CAC, CHG-SVR-CAC
Engineering rules Max call count * callCACThreshForNormal is calculated to execute
the CAC for the Normal call in Server unit.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-103


CHAPTER 2. Parameter Description

CALL_COUNT_CAC_USAGE
Parameter name CALL_COUNT_CAC_USAGE
Description Whether to perform capacity based CAC (Call Admission Control)
per base station.
- CI_no_use: Does not perform capacity based CAC per base
station.
- CI_use: Performs capacity based CAC per base station.
Object class & hierarchy PLDEnbCacInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-ENB-CAC, CHG-ENB-CAC
Engineering rules This is the parameter that indicates whether CAC in eNB unit is
executed or not.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-104 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CALL_COUNT_CAC_USAGE
Parameter name CALL_COUNT_CAC_USAGE
Description Whether to perform call count based CAC among server-based
capacity based CAC (Call Admission Control) functions.
- CI_no_use: Does not perform capacity based CAC per server.
- CI_use: Performs capacity based CAC per server.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-SVR-CAC, CHG-SVR-CAC
Engineering rules This is the parameter that indicates whether CAC in Server unit is
executed or not.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-105


CHAPTER 2. Parameter Description

CC_ID
Parameter name CC_ID
Description Channel card ID (Unique in the system)
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This indicates the Channel Card ID information.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-106 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CCO_T304
Parameter name CCO_T304
Description Value of a timer that is started by an eNB when it receives the
Mobility From EUTRA Command message during handover.
The timer is cleared if cell change order is successfully executed to
the Inter RAT. The default is 200 ms and an operator can change it
during operation.
- ci_cco_t_304_ms100: 100 ms.
- ci_cco_t_304_ms200: 200 ms.
- ci_cco_t_304_ms500: 500 ms.
- ci_cco_t_304_ms1000: 1000 ms.
- ci_cco_t_304_ms2000: 2000 ms.
- ci_cco_t_304_ms4000: 4000 ms.
- ci_cco_t_304_ms8000: 8000 ms.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_cco_t_304_ms100/ci_cco_t_304_ms200/ci_cco_t_304_ms500/
ci_cco_t_304_ms1000/ci_cco_t_304_ms2000/
ci_cco_t_304_ms4000/ci_cco_t_304_ms8000
Read/Write READ/WRITE
Default value ci_cco_t_304_ms1000
Rec. Value ci_cco_t_304_ms1000
Commands RTRV-TIME-INF, CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-107


CHAPTER 2. Parameter Description

CELL_BARRED
Parameter name CELL_BARRED
Description Whether a cell is barred or not.
- ci_Barred: A cell is barred.
- ci_notBarred: A cell is not barred.
If the cell status becomes shutdown, the cellBarred value of SIB1
becomes ci_barred. Also, when an operator set this parameter to
ci_barred, the cellBarred value of SIB1 becomes ci_barred and it is
broadcasted.
Object class & hierarchy PLDCellAccessInfoLogic
Type Static
Data Type short
Unit NA
Range ci_barred/ci_notBarred
Read/Write READ/WRITE
Default value ci_notBarred
Rec. Value ci_notBarred
Commands RTRV-CELL-ACS, CHG-CELL-ACS
Engineering rules If this parameter is set to ci_barred, call service is not available for
the cell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-108 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_COUNT_CAC_USAGE
Parameter name CELL_COUNT_CAC_USAGE
Description Whether to perform call count based CAC among cell-based
capacity based CAC (Call Admission Control) functions.
- CI_no_use: Does not perform capacity based CAC per cell.
- CI_use: Performs capacity based CAC per cell.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-CELL-CAC, CHG-CELL-CAC
Engineering rules This is the parameter that determines whether or not CAC for the
call count based on the Cell is executed or not. It is not executed if
the parameter is 0, and executed if the parameter is 1.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-109


CHAPTER 2. Parameter Description

CELL_ID
Parameter name CELL_ID
Description ID of a GERAN neighbor cell around a base station
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN, CHG-NBR-GERAN, CRTE-NBR-GERAN,
DLT-NBR-GERAN
Engineering rules This is the only value that can distinguish the GERAN Cell within
the GERAN location area, and the entry can be from 0 to 65,535.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

CELL_IDENTITY
Parameter name CELL_IDENTITY
Description Indicates cell Identity.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range 0~268435455
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-IDLE, CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-110 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDBarringParam
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-BAR-PARA, CHG-BAR-PARA
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-BLACK-LIST, CHG-BLACK-LIST, CRTE-BLACK-LIST,
DLT-BLACK-LIST
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-111


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDBlindCCOconf
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-BLCCO, CHG-GERAN-BLCCO
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description Cell no. Maximum input value is the maximum number of cells
supported by the system. Its maximum value is determined by
FA/Sector. For example, max. 3 cells are supported if the maximum
capacity per system of a service provider is 1 FA/3 Sector.
Object class & hierarchy PLDCallPlmnState
Type Static
Data Type word16
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CALLPLMN-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-112 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description Cell no. Maximum input value is the maximum number of cells
supported by the system. Its maximum value is determined by
FA/Sector. For example, max. 3 cells are supported if the maximum
capacity per system of a service provider is 1 FA/3 Sector.
Object class & hierarchy PLDCallState
Type Static
Data Type word16
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CALL-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDCellAccessIdle
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CAS-IDLE, CHG-CAS-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-113


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDCellAccessInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CELL-ACS, CHG-CELL-ACS
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CELL-CAC, CHG-CELL-CAC
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-114 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description Cell no. Maximum input value is the maximum number of cells
supported by the system. Its maximum value is determined by
FA/Sector. For example, max. 3 cells are supported if the maximum
capacity per system of a service provider is 1 FA/3 Sector.
Object class & hierarchy PLDCellPlmnState
Type Static
Data Type word16
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELLPLMN-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDCellReselectInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CELL-RSEL, CHG-CELL-RSEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-115


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CELL-SEL, CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description Cell no. Maximum input value is the maximum number of cells
supported by the system. Its maximum value is determined by
FA/Sector. For example, max. 3 cells are supported if the maximum
capacity per system of a service provider is 1 FA/3 Sector.
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-116 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CSGPCI-IDLE, CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A1CNF, CHG-EUTRA-A1CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-117


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A2CNF, CHG-EUTRA-A2CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A3CNF, CHG-EUTRA-A3CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-118 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A4CNF, CHG-EUTRA-A4CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A5CNF, CHG-EUTRA-A5CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-119


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-FA, CHG-EUTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CELL-IDLE, CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-120 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-PRIOR, CHG-EUTRA-PRIOR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-121


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-PRD, CHG-EUTRA-PRD
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word32
Unit NA
Range 0-2
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-NBR-EUTRAN, CHG-NBR-EUTRAN, CRTE-NBR-EUTRAN,
DLT-NBR-EUTRAN
Engineering rules
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-122 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description Indicates the eNB Cell Number to which the GERAN Neighbor Cell
belongs.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range 0-2
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN, CHG-NBR-GERAN, CRTE-NBR-GERAN,
DLT-NBR-GERAN
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-123


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range 0-2
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN, CHG-NBR-UTRAN, CRTE-NBR-UTRAN,
DLT-NBR-UTRAN
Engineering rules This value indicates the eNB Cell Number to which the UTRAN
Neighbor Cell belongs.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to retrieve
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-B1CNF, CHG-GERAN-B1CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-124 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-B2CNF, CHG-GERAN-B2CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDGeranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-PRIOR, CHG-GERAN-PRIOR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-125


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA, CHG-GERAN-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-INTWO, CHG-GERAN-INTWO
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-126 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDGeranPeriodicInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-PRD, CHG-GERAN-PRD
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDGeranReselectInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-RESEL, CHG-GERAN-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-127


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDHybridPciInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-HYBRIDPCI-INF, CHG-HYBRIDPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDInterworkControlInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-INTWO-OPT, CHG-INTWO-OPT
Engineering rules This value specifies the Cell Number for changing the Interworking
Options. Please note that an entry can be made for each cell.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-128 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDMeasurementInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-MEAS-FUNC, CHG-MEAS-FUNC
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDMobilityStateInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-MOBIL-STA, CHG-MOBIL-STA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-129


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description Specifies a cell index to change/retrieve.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR, CHG-NET-SHR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDOpenPciInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-OPENPCI-INF, CHG-OPENPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-130 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell for which a command is executed.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-POS-CONF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDQosCacParam
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-QCAC-PARA, CHG-QCAC-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-131


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of call to change.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-QCACQ-PARA, CHG-QCACQ-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDQuantityConfigEutra
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-QUANT-EUTRA, CHG-QUANT-EUTRA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-132 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDQuantityConfigGeran
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-QUANT-GERAN, CHG-QUANT-GERAN
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDQuantityConfigUtra
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-QUANT-UTRA, CHG-QUANT-UTRA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-133


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDSibSchedulingIdle
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-SIB-IDLE, CHG-SIB-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDSibSchedulingInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-SIB-INF, CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-134 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-TIME-INF, CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-B1CNF, CHG-UTRA-B1CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-135


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-B2CNF, CHG-UTRA-B2CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR, CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-136 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA, CHG-UTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDUtranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-PRIOR, CHG-UTRA-PRIOR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-137


CHAPTER 2. Parameter Description

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change
Object class & hierarchy PLDUtraPeriodicInfo
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-PRD, CHG-UTRA-PRD
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

CELL_NUM
Parameter name CELL_NUM
Description No. of a cell to change/retrieve
Object class & hierarchy PLDUtraReselectInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-RESEL, CHG-UTRA-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-138 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_PARA_ID
Parameter name CELL_PARA_ID
Description Cell parameter ID information of a UTRAN neighbor cell around a
base station. (TDD)
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-127
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN, CHG-NBR-UTRAN, CRTE-NBR-UTRAN,
DLT-NBR-UTRAN
Engineering rules This parameter indicates the Physical Cell ID of the UTRAN
Neighbor Cell, which is the TDD type that exists around eNB.
Entry can be from 0 up to 127, but the precise value of the UTRAN
Neighbor Cell must be entered.
Caution/Note Please note that the entry must not be the same as previously
registered value. (If cellParaID and arfcnDl are the same, then the
system determines the entry as repeated entry.)
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-139


CHAPTER 2. Parameter Description

CELL_RESERVED_OP_USE0
Parameter name CELL_RESERVED_OP_USE0
Description cellReservedOpUse of PLMN #0. This is broadcasted to a UE
through SIB (System Information Block) 1.
- ci_Reserved: A UE that has a specific AC (Access Class) for
PLMN #0 can perform selection/re-selection.
- ci_notReserved: A UE that has all the AC (Access Class) for
PLMN #0 can perform selection/re-selection.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type enum
Unit NA
Range ci_reserved/ci_notReserved
Read/Write READ/WRITE
Default value ci_notReserved
Rec. Value ci_notReserved
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-140 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_RESERVED_OP_USE1
Parameter name CELL_RESERVED_OP_USE1
Description cellReservedOpUse of PLMN #1. This is broadcasted to a UE
through SIB 1.
- ci_Reserved: A UE that has a specific AC (Access Class) for
PLMN #1 can perform selection/re-selection.
- ci_notReserved: A UE that has all the AC (Access Class) for
PLMN #1 can perform selection/re-selection.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type int
Unit NA
Range ci_reserved/ci_notReserved
Read/Write READ/WRITE
Default value ci_notReserved
Rec. Value ci_notReserved
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-141


CHAPTER 2. Parameter Description

CELL_RESERVED_OP_USE2
Parameter name CELL_RESERVED_OP_USE2
Description cellReservedOpUse of PLMN #2. This is broadcasted to a UE
through SIB 1.
- ci_Reserved: A UE that has a specific AC (Access Class) for
PLMN #2 can perform selection/re-selection.
- ci_notReserved: A UE that has all the AC (Access Class) for
PLMN #2 can perform selection/re-selection.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type int
Unit NA
Range ci_reserved/ci_notReserved
Read/Write READ/WRITE
Default value ci_notReserved
Rec. Value ci_notReserved
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-142 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_RESERVED_OP_USE3
Parameter name CELL_RESERVED_OP_USE3
Description cellReservedOpUse of PLMN #3. This is broadcasted to a UE
through SIB 1.
- ci_Reserved: A UE that has a specific AC (Access Class) for
PLMN #3 can perform selection/re-selection.
- ci_notReserved: A UE that has all the AC (Access Class) for
PLMN #3 can perform selection/re-selection.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type int
Unit NA
Range ci_reserved/ci_notReserved
Read/Write READ/WRITE
Default value ci_notReserved
Rec. Value ci_notReserved
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-143


CHAPTER 2. Parameter Description

CELL_RESERVED_OP_USE4
Parameter name CELL_RESERVED_OP_USE4
Description cellReservedOpUse of PLMN #4. This is broadcasted to a UE
through SIB 1.
- ci_Reserved: A UE that has a specific AC (Access Class) for
PLMN #4 can perform selection/re-selection.
- ci_notReserved: A UE that has all the AC (Access Class) for
PLMN #4 can perform selection/re-selection.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type int
Unit NA
Range ci_reserved/ci_notReserved
Read/Write READ/WRITE
Default value ci_notReserved
Rec. Value ci_notReserved
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-144 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_RESERVED_OP_USE5
Parameter name CELL_RESERVED_OP_USE5
Description Broadcasted.
- ci_Reserved: A UE that has a specific AC (Access Class) for
PLMN #5 can perform selection/re-selection.
- ci_notReserved: A UE that has all the AC (Access Class) for
PLMN #5 can perform selection/re-selection.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type int
Unit NA
Range ci_reserved/ci_notReserved
Read/Write READ/WRITE
Default value ci_notReserved
Rec. Value ci_notReserved
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-145


CHAPTER 2. Parameter Description

CELL_SIZE
Parameter name CELL_SIZE
Description Cell size.
- ci_cellsize_verysmall: Smallest cell.
- ci_cellsize_small: Small size cell.
- ci_cellsize_medium: Middle size cell.
- ci_cellsize_large: Large size cell.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type unsigned_int
Unit NA
Range ci_cellsize_verysmall/ci_cellsize_small/ci_cellsize_medium/
ci_cellsize_large
Read/Write READ/WRITE
Default value ci_cellsize_large
Rec. Value ci_cellsize_large
Commands RTRV-CELL-INFO, CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-146 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CELL_TYPE
Parameter name CELL_TYPE
Description Cell operation type.
- macroCell: Operates many normal cells.
- openCell: Operates a single normal cell.
- hybridCell: Operates CSG cells as well as normal cells.
- csgCell: Operates only CSG (Closed Subscriber Group) cells.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range macroCell/openCell/hybridCell/csgCell
Read/Write READ/WRITE
Default value macroCell
Rec. Value macroCell
Commands RTRV-CELL-IDLE, CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-147


CHAPTER 2. Parameter Description

CHECK_UE_ID_USAGE
Parameter name CHECK_UE_ID_USAGE
Description This parameter determines whether to perform repeated entry
checks for S-TMSI (SAE Temporary Mobile Station Identifier) for a
new call.
- CI_no_use: S-TMSI duplication check is not performed.
- CI_use: S-TMSI duplication check is performed.
Object class & hierarchy PLDEnbCacInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-ENB-CAC, CHG-ENB-CAC
Engineering rules If it is a duplicate, the existing call is released and the new call is
accepted.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-148 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

C_ID
Parameter name C_ID
Description CID of a UTRAN neighbor cell around a base station
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN, CHG-NBR-UTRAN, CRTE-NBR-UTRAN,
DLT-NBR-UTRAN
Engineering rules This parameter indicates the C-ID value of the UTRAN Neighboring
Cell. This data must be accurately entered in order to execute RIM
process. The SI of the UTRAN Neighboring Cell, obtained through
the RIM process, is used during CSFB with 3G SIB operation.
Caution/Note The exact C-ID value set in the UTRAN Neighboring Cell must be
entered.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-149


CHAPTER 2. Parameter Description

CIPHER_EA_PRIOR
Parameter name CIPHER_EA_PRIOR
Description Ciphering algorithm information supported by a base station.
- EEA0: NULL.
- EEA1: SNOW 3G.
- EEA2: AES.
Object class & hierarchy PLDSecurityInfoFunc
Type Static
Data Type word32
Unit NA
Range EEA0/EEA1/EEA2
Read/Write READ/WRITE
Default value EEA1
Rec. Value EEA1
Commands RTRV-SECU-INF, CHG-SECU-INF
Engineering rules This is the Integrity Protection algorithm information supported by
the Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-150 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CLASS_ID
Parameter name CLASS_ID
Description Signal Class Id in a base station. Each Class Id is defined as
follows:
- S1 Signaling
- X2 Signaling
- S1/X2-U management
Object class & hierarchy PLDSigDSCPData
Type Static
Data Type word32
Unit NA
Range 0-2
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-SIGDSCP-DATA, CHG-SIGDSCP-DATA
Engineering rules This is the Class ID to define the DSCP value of the Signaling
message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-151


CHAPTER 2. Parameter Description

COMMON_SHARING_PORTION
Parameter name COMMON_SHARING_PORTION
Description Common allocation amount for network resources of a cell in a
base station
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-NET-SHR, CHG-NET-SHR
Engineering rules This is a portion of the Cell resources commonly used within a
Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

CONFIDENCE
Parameter name CONFIDENCE
Description Accuracy of GPS service (%)
Object class & hierarchy PLDPositioningConf
Type Static
Data Type %
Unit NA
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-POS-CONF, CHG-POS-CONF
Engineering rules Enters the accuracy of the position data input by the operator in
percentage. The closer the value is to 100 %, the higher the
accuracy.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-152 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CONNECT_INTERVAL
Parameter name CONNECT_INTERVAL
Description If the SCTP link is not configured although this is a peer node
equipped to PLD, periodic connection is tried based on this timer
value.
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit sec
Range 1-10
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-SCTP-PARA, CHG-SCTP-PARA
Engineering rules If the node to be set for the SCTP Link is EQUIP in PLD, but there
still exists a node that is not yet established the SCTP Connection,
then an INIT message is transmitted based on the connect Interval
setting to make the SCTP Connection.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-153


CHAPTER 2. Parameter Description

CSFB_OPTION
Parameter name CSFB_OPTION
Description Defines operation type when CSFB indication is received.
- ueCapability: by UE Capability
- blind: Blind CSFB
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range geranCsfbByUecapa/geranCsfbByBlind
Read/Write READ/WRITE
Default value geranCsfbByBlind
Rec. Value geranCsfbByBlind
Commands RTRV-GERAN-INTWO/CHG-GERAN-INTWO
Engineering rules The corresponding parameter indicates the CSFB operation type if
the CSFB indicator is received. If the parameter is set to blind, then
Blind CSFB is executed regardless of UE Capability. If it is set to
ueCapability, then the operation type is determined based on the
UE Capability.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-154 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CSG_IDENTITY
Parameter name CSG_IDENTITY
Description ID when a cell is a CSG (Closed Subscriber Group) cell.
Object class & hierarchy PLDCellAccessIdle
Type Static
Data Type word32
Unit NA
Range 0-134217727
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CAS-IDLE, CHG-CAS-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

CSG_PCIRANGE
Parameter name CSG_PCIRANGE
Description PCI range of a CSG cell. The range includes the starting value.
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range ci_rangePCI_n4/ci_rangePCI_n8/ci_rangePCI_n12/
ci_rangePCI_n16/ci_rangePCI_n24/ci_rangePCI_n32/
ci_rangePCI_n48/ci_rangePCI_n64/ci_rangePCI_n84/
ci_rangePCI_n96/ci_rangePCI_n128/ci_rangePCI_n168/
ci_rangePCI_n252/ci_rangePCI_n504
Read/Write READ/WRITE
Default value ci_rangePCI_n84
Rec. Value ci_rangePCI_n84
Commands RTRV-CSGPCI-IDLE, CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-155


CHAPTER 2. Parameter Description

CSG_PCIRANGE_USAGE
Parameter name CSG_PCIRANGE_USAGE
Description Whether to use PCI range of a CSG cell.
- CI_no_use: PCI range is not used.
- CI_use: PCI range is used.
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-CSGPCI-IDLE, CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

CSG_PCISTART
Parameter name CSG_PCISTART
Description PCI start value of a CSG cell
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range 0-503
Read/Write READ/WRITE
Default value 420
Rec. Value 420
Commands RTRV-CSGPCI-IDLE, CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-156 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

CSL_IPV4
Parameter name CSL_IPV4
Description IPv4 type CSL Server IP address
Object class & hierarchy PLDCslInfo
Type Static
Data Type IPv4Address
Unit NA
Range -
Read/Write READ/WRITE
Default value ‘0.0.0.0’
Rec. Value ‘0.0.0.0’
Commands RTRV-CSL-INF, CHG-CSL-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

CSL_IPV6
Parameter name CSL_IPV6
Description IPv6 type CSL Server IP address
Object class & hierarchy PLDCslInfo
Type Static
Data Type IPv6Address
Unit NA
Range -
Read/Write READ/WRITE
Default value ‘0:0:0:0:0:0:0:0’
Rec. Value ‘0:0:0:0:0:0:0:0’
Commands RTRV-CSL-INF, CHG-CSL-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-157


CHAPTER 2. Parameter Description

2.4 D
DEDICATED_PRIORITY
Parameter name DEDICATED_PRIORITY
Description Dedicated priority value according to the SPID of a corresponding
frequency.
Object class & hierarchy PLDEutranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-EUTRA-PRIOR, CHG-EUTRA-PRIOR
Engineering rules This is the Idle Mode Priority value corresponding to Eutra
Frequency. The corresponding Priority value is sent when call is
released.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-158 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DEDICATED_PRIORITY
Parameter name DEDICATED_PRIORITY
Description Dedicated priority value according to the SPID of a corresponding
frequency.
Object class & hierarchy PLDGeranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-GERAN-PRIOR, CHG-GERAN-PRIOR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

DEDICATED_PRIORITY
Parameter name DEDICATED_PRIORITY
Description Dedicated priority value according to the SPID of a corresponding
frequency.
Object class & hierarchy PLDUtranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-UTRA-PRIOR, CHG-UTRA-PRIOR
Engineering rules This is the Idle Mode Priority value corresponding to Utra
Frequency. The corresponding Priority value is sent when call is
released.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-159


CHAPTER 2. Parameter Description

DIAG_CALL_ENABLE
Parameter name DIAG_CALL_ENABLE
Description On/Off information whether to perform the diagnosis call function.
Object class & hierarchy PLDDiagCallConf
Type Static
Data Type word32
Unit NA
Range OFF/ON
Read/Write READ/WRITE
Default value OFF
Rec. Value OFF
Commands RTRV-DIAG-CONF, CHG-DIAG-CONF
Engineering rules Diagnosis Signal feature is for checking a specific Cell for error if
the corresponding Cell has no connection signal for a certain
period of time. It sends Paging messages to a device for diagnosis.
- OFF: Diagnosis Signal feature is deactivated.
- ON: Diagnosis Signal feature is activated.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-160 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DIAG_CALL_TIMER
Parameter name DIAG_CALL_TIMER
Description Time information for the diagnosis call function. If the diagnosis call
function is working, the base station checks the IMSI, S-TMSI
value stored in a buffer, performs paging to the corresponding UE,
and waits for the reply. This is the timer setting used for this case.
Object class & hierarchy PLDDiagCallConf
Type Static
Data Type word16
Unit sec
Range 1-10
Read/Write READ/WRITE
Default value 5
Rec. Value 5
Commands RTRV-DIAG-CONF, CHG-DIAG-CONF
Engineering rules If RRC Connection Request message is not received within
DIAG_CALL_TIMER after transmitting Paging message to a
device, then an alarm is triggered for the corresponding Cell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-161


CHAPTER 2. Parameter Description

DISCARD_TIMER
Parameter name DISCARD_TIMER
Description Discard timer value for a packet butter managed per RB in the RLC
AM mode. If no ACK is received from RLC for a certain period of
time, the packet is discarded in the packet buffer.
- ci_discardTimer_ms50: 50 msec.
- ci_discardTimer_ms100: 100 msec.
- ci_discardTimer_ms150: 150 msec.
- ci_discardTimer_ms300: 300 msec.
- ci_discardTimer_ms500: 500 msec.
- ci_discardTimer_ms750: 750 msec.
- ci_discardTimer_ms1500: 1500 msec.
- ci_discardTimer_infinity: discard timer function off (default).
Object class & hierarchy PLDPdcpInfoFunc
Type Static
Data Type word32
Unit NA
Range ci-discardTimer_ms50/ci-discardTimer_ms100/
ci-discardTimer_ms150/ci-discardTimer_ms300/
ci-discardTimer_ms500/ci-discardTimer_ms750/
ci-discardTimer_ms1500/ci-discardTimer_infinity
Read/Write READ/WRITE
Default value ci_discardTimer_infinity
Rec. Value ci_discardTimer_infinity
Commands RTRV-PDCP-INF, CHG-PDCP-INF
Engineering rules This is the discard timer value for the packet buffer managed per
RB in the RLC AM mode. If ACK is not received from the RLC
within the preset time, then the corresponding packet from the
packet buffer is discarded.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-162 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DL_ANT_COUNT
Parameter name DL_ANT_COUNT
Description Number of Tx antennas used by an operating cell.
- ci_n1TxAntCnt: One Tx antenna is used.
- ci_n2TxAntCnt: Two Tx antennas are used.
- ci_n4TxAntCnt: Four Tx antennas are used.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range ci_n1TxAntCnt/ci_n2TxAntCnt/ci_n4TxAntCnt
Read/Write READ/WRITE
Default value ci_n2TxAntCnt
Rec. Value ci_n2TxAntCnt
Commands RTRV-CELL-IDLE, CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-163


CHAPTER 2. Parameter Description

DL_BANDWIDTH
Parameter name DL_BANDWIDTH
Description Downlink bandwidth used by an operating cell.
- ci_SystemBandwidth_n6: 1.4MHz bandwidth which uses the 6
physical resource blocks (RBs)
- ci_SystemBandwidth_n15: 3MHz bandwidth which uses 15
physical RBs
- ci_SystemBandwidth_n25: 5MHz bandwidth which uses 25
physical RBs
- ci_SystemBandwidth_n50: 10MHz bandwidth which uses 50
physical RBs
- ci_SystemBandwidth_n75: 15MHz bandwidth which uses 75
physical RBs
- ci_SystemBandwidth_n100: 20MHz bandwidth which uses 100
physical RBs
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type short
Unit NA
Range ci_SystemBandwidth_n6/ci_SystemBandwidth_n15/
ci_SystemBandwidth_n25/ci_SystemBandwidth_n50/
ci_SystemBandwidth_n75/ci_SystemBandwidth_n100
Read/Write READ/WRITE
Default value ci_SystemBandwidth_n50
Rec. Value ci_SystemBandwidth_n50
Commands RTRV-CELL-IDLE, CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-164 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DL_GBRUSAGE_THRESH_HO
Parameter name DL_GBRUSAGE_THRESH_HO
Description Percentage of GBR that can be allocated as downlink for a
handover call. If the downlink GBR PRB usage amount exceeds
the entered parameter ratio when a handover call is requested, the
QoS CAC Fail is generated.
Object class & hierarchy PLDQosCacParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-QCAC-PARA, CHG-QCAC-PARA
Engineering rules This is the handover threshold of the Downlink GBR.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-165


CHAPTER 2. Parameter Description

DL_GBRUSAGE_THRESH_NORMAL
Parameter name DL_GBRUSAGE_THRESH_NORMAL
Description Percentage of GBR that can be allocated as downlink for a new
call. If the downlink GBR PRB usage amount exceeds the entered
parameter ratio when a new call is requested, the QoS CAC Fail is
generated.
Object class & hierarchy PLDQosCacParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 80
Rec. Value 80
Commands RTRV-QCAC-PARA, CHG-QCAC-PARA
Engineering rules This is the normal threshold of the Downlink GBR.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-166 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DL_QCIUSAGE_THRESH_HO
Parameter name DL_QCIUSAGE_THRESH_HO
Description Percentage of GBR that can be allocated per QCI (QoS Class
Identifier) as downlink for a handover call. If the downlink GBR
PRB usage amount exceeds the entered parameter ratio when a
handover call is requested, the QoS CAC Fail is generated.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-QCACQ-PARA, CHG-QCACQ-PARA
Engineering rules This is the Handover threshold of the Downlink GBR, allocated to
each QCI.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-167


CHAPTER 2. Parameter Description

DL_QCIUSAGE_THRESH_NORMAL
Parameter name DL_QCIUSAGE_THRESH_NORMAL
Description Percentage of GBR that can be allocated per QCI (QoS Class
Identifier) as downlink for a new call. If the downlink GBR PRB
usage amount exceeds the entered parameter ratio when a new
call is requested, the QoS CAC Fail is generated.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 80
Rec. Value 80
Commands RTRV-QCACQ-PARA/CHG-QCACQ-PARA
Engineering rules This is the Normal threshold of the Downlink GBR, allocated to
each QCI.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-168 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DRB_CAC_THRESH_FOR_EMER_HO
Parameter name DRB_CAC_THRESH_FOR_EMER_HO
Description Acceptable percentage for emergency calls and handover calls.
If the number of connected calls exceeds ‘MAX_DRB_COUNT *
DRB_CAC_THRESH_FOR_EMER_HO’ when a normal call is
requested, the Capacity based CAC Fail is generated.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules Max DRB count * drbCACThreshForEmerHo is calculated to
execute DRB CAC for the Emergency call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-169


CHAPTER 2. Parameter Description

DRB_CAC_THRESH_FOR_EMER_HO
Parameter name DRB_CAC_THRESH_FOR_EMER_HO
Description Acceptable percentage for emergency calls and handover calls.
If the number of connected calls exceeds ‘MAX_DRB_COUNT *
DRB_CAC_THRESH_FOR_EMER_HO’ when a normal call is
requested, the Capacity based CAC Fail is generated.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-SVR-CAC/CHG-SVR-CAC
Engineering rules Max DRB count * drbCACThreshForEmerHo is calculated to
execute DRB CAC for the Emergency call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-170 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DRB_CAC_THRESH_FOR_NORMAL
Parameter name DRB_CAC_THRESH_FOR_NORMAL
Description Acceptable percentage for normal calls. If the number of connected
calls exceeds ‘MAX_CALL_COUNT * CALL_CAC_THRESH_
FOR_NORMAL’ when a normal call is requested, the Capacity
based CAC Fail is generated.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 90
Rec. Value 90
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules Max DRB count * drbCACThreshForNormalHo is calculated to
execute DRB CAC for the Normal call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-171


CHAPTER 2. Parameter Description

DRB_CAC_THRESH_FOR_NORMAL
Parameter name DRB_CAC_THRESH_FOR_NORMAL
Description Acceptable percentage for normal calls. If the number of connected
calls exceeds ‘MAX_CALL_COUNT * CALL_CAC_THRESH_
FOR_NORMAL’ when a normal call is requested, the Capacity
based CAC Fail is generated.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word16
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 90
Rec. Value 90
Commands RTRV-SVR-CAC/CHG-SVR-CAC
Engineering rules Max DRB count * drbCACThreshForNormalHo is calculated to
execute DRB CAC for the Normal call.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

DRB_CNT
Parameter name DRB_CNT
Description Number of E-RAB (E-Utran Radio Access Bearer) configured per
QCI
Object class & hierarchy PLDCallPlmnState
Type Static
Data Type int
Unit NA
Range -1-36000
Read/Write Read Only
Default value -1
Rec. Value -1
Commands RTRV-CALLPLMN-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change This is the Status pld value and is used only for search.
Need to reset No

2-172 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DRB_CNT
Parameter name DRB_CNT
Description Number of E-RAB (E-Utran Radio Access Bearer) configured per
QCI
Object class & hierarchy PLDCallState
Type Static
Data Type int
Unit NA
Range -1-36000
Read/Write Read Only
Default value -1
Rec. Value -1
Commands RTRV-CALL-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change This is the Status pld value and is used only for search.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-173


CHAPTER 2. Parameter Description

DRB_COUNT_CAC_USAGE
Parameter name DRB_COUNT_CAC_USAGE
Description Whether to perform E-RAB (E-UTRAN Radio Access Bearer)
based CAC among cell-based capacity based CAC (Call Admission
Control) functions
- CI_no_use: The E-RAB number based CAC function per cell is
not performed.
- CI_use: The E-RAB number based CAC function per cell is
performed.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the parameter that determines whether CAC for the DRB
count is executed or not. If the parameter is set to CI_no_use, then
CAC is not executed. If the parameter is set to CI_use, then CAC is
executed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-174 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DRB_COUNT_CAC_USAGE
Parameter name DRB_COUNT_CAC_USAGE
Description Whether to perform E-RAB (E-UTRAN Radio Access Bearer)
based CAC among server-based capacity based CAC (Call
Admission Control) functions
- CI_no_use: The E-RAB number based CAC function per server is
not performed.
- CI_use: The E-RAB number based CAC function per server is
performed.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-SVR-CAC/CHG-SVR-CAC
Engineering rules This is the ON/OFF control parameter for the DRB CAC function.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-175


CHAPTER 2. Parameter Description

DSCP
Parameter name DSCP
Description DSCP value to set up per traffic type (QCI).
Object class & hierarchy PLDQciDSCPMapInfoFunc
Type Static
Data Type unsigned_int
Unit NA
Range 0-63
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-QCIDSCP-MAP/CHG-QCIDSCP-MAP
Engineering rules The corresponding parameter is the DSCP value for the
corresponding QCI. When transmitting Uplink Traffic to S-GW, the
eNB sets the DSCP value of the corresponding backhaul IP as the
DSCP value mapped for each QCI.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

DSCP
Parameter name DSCP
Description The DSCP value depends on signal class Id.
Object class & hierarchy PLDSigDSCPData
Type Static
Data Type word32
Unit NA
Range 0-63
Read/Write READ/WRITE
Default value 40
Rec. Value 40
Commands RTRV-SIGDSCP-DATA/CHG-SIGDSCP-DATA
Engineering rules This signifies the DSCP value defined in the Signaling message,
and the message transmission priority order is set, based on the
DSCP value.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-176 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DTM_SUPPORT
Parameter name DTM_SUPPORT
Description Whether a GERAN neighbor cell supports DTM.
- False: VoIP is not supported.
- True: VoIP is supported.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates whether the DTM (Dual Transfer Mode) of
a GERAN Neighboring Cell is supported or not. It determines the
operation with PS HO during SRVCC operation.
Caution/Note Whether the DTM of a GERAN Neighboring Cell is supported or
not must be entered accurately.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-177


CHAPTER 2. Parameter Description

DUPLEX_TYPE
Parameter name DUPLEX_TYPE
Description Communication type used during cell operation.
- ci_FDD: Frequency Division Duplex,
- ci_TDD: Time Division Duplex,
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range ci_FDD/ci_TDD
Read/Write READ/WRITE
Default value ci_FDD
Rec. Value ci_FDD
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-178 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DUPLEX_TYPE
Parameter name DUPLEX_TYPE
Description Duplex type information of a UTRAN neighbor cell around a base
station.
- ci_FDD: Frequency Division Duplex,
- ci_TDD: Time Division Duplex,
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range ci_FDD/ci_TDD
Read/Write READ/WRITE
Default value ci_FDD
Rec. Value ci_FDD
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules -
Caution/Note The duplex Type of the UTRAN Neighboring Cell must be entered
accurately.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-179


CHAPTER 2. Parameter Description

DUPLEX_TYPE
Parameter name DUPLEX_TYPE
Description Duplex mode information of a cell. The cell duplex mode includes
FDD and TDD.
- ci_FDD: Frequency Division Duplex,
- ci_TDD: Time Division Duplex,
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type enum
Unit NA
Range ci_FDD/ci_TDD
Read/Write READ/WRITE
Default value ci_FDD
Rec. Value ci_FDD
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-180 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

DUPLEX_TYPE
Parameter name DUPLEX_TYPE
Description Duplex mode information of a cell. The cell duplex mode includes
FDD and TDD.
- ci_FDD: Frequency Division Duplex,
- ci_TDD: Time Division Duplex,
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type enum
Unit NA
Range ci_FDD/ci_TDD
Read/Write READ/WRITE
Default value ci_FDD
Rec. Value ci_FDD
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This is the Duplex Mode of the UTRA FA.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-181


CHAPTER 2. Parameter Description

2.5 E
EARFCN_DL
Parameter name EARFCN_DL
Description Downlink EARFCN (E-UTRA Absolute Radio Frequency Channel
Number) of a black list cell
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 2525
Rec. Value 2525
Commands RTRV-BLACK-LIST/CHG-BLACK-LIST/CRTE-BLACK-LIST/
DLT-BLACK-LIST
Engineering rules Set the Downlink EARFCN of the blacklisted Cell. Measurement
will not be made for a device if a Cell specified is on the blacklist.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-182 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

EARFCN_DL
Parameter name EARFCN_DL
Description Downlink E-UTRA Absolute Radio Frequency Channel Number.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 2525
Rec. Value 2525
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is for setting the Downlink EARFCN for E-UTRA
Frequency. Run the Data Rule Check (DRC) based on the EQUIP
state to prevent repeated entries.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-183


CHAPTER 2. Parameter Description

EARFCN_DL
Parameter name EARFCN_DL
Description Downlink ARFCN (Absolute Radio Frequency Channel Number)
used in the EUTRAN (Evolved Universal Terrestrial Radio Access
Network) system of an operating cell. The center frequency must
be changed to EARFCN (E-UTRA Absolute Radio Frequency
Channel Number) (refer to 3GPP TS 36.101, 5.7.3).
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 2525
Rec. Value 2525
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-184 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

EARFCN_DL
Parameter name EARFCN_DL
Description Downlink EARFCN (E-UTRAN Absolute Radio Frequency Channel
Number) of E-UTRAN neighbor cell located around a base station.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 2525
Rec. Value 2525
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Downlink ARFCN of the EUTRAN
Neighbor Cell. This information is shared between Base Stations
via X2 message, and is used during Handover attempts.
Caution/Note As a precaution, do not enter previously entered information. (If the
Physical Cell Id and earfcnDl is the same, the system will deem it
to be a repeated entry.)
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-185


CHAPTER 2. Parameter Description

EARFCN_DL
Parameter name EARFCN_DL
Description Downlink ARFCN that specifies idle mode load distribution.
Object class & hierarchy PLDIdleModeLbInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-IDLELB-INFO/CHG-IDLELB-INFO
Engineering rules This parameter is for the information transmitted to a device during
Idle Mode Load Distribution. Accurately set the information you
want to send to a device.
Caution/Note Accurately enter the frequency information used by a neighboring
eNB.
Delta NA
Real time change Yes
Need to reset No

2-186 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

EARFCN_UL
Parameter name EARFCN_UL
Description Uplink EARFCN (E-UTRA Absolute Radio Frequency Channel
Number) of a black list cell
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 20500
Rec. Value 20500
Commands RTRV-BLACK-LIST/CHG-BLACK-LIST/CRTE-BLACK-LIST/
DLT-BLACK-LIST
Engineering rules This parameter is for setting the uplink EARFCN of the blacklisted
Cell. Measurement will not be made for a device if a Cell specified
is on the blacklist.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-187


CHAPTER 2. Parameter Description

EARFCN_UL
Parameter name EARFCN_UL
Description E-UTRA Uplink Absolute Radio Frequency Channel Number.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 20500
Rec. Value 20500
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is for setting the Uplink EARFCNfor the E-UTRA
Frequency. Unlike the setting for the Downlink EARFCN, repeated
entry check is not performed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-188 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

EARFCN_UL
Parameter name EARFCN_UL
Description Uplink ARFCN (Absolute Radio Frequency Channel Number) used
in the EUTRAN (Evolved Universal Terrestrial Radio Access
Network) system of an operating cell. The center frequency must
be changed to EARFCN (Refer to 3GPP TS 36.101, 5.7.3).
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 20500
Rec. Value 20500
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-189


CHAPTER 2. Parameter Description

EARFCN_UL
Parameter name EARFCN_UL
Description Uplink EARFCN (E-UTRAN Absolute Radio Frequency Channel
Number) of a E-UTRAN neighbor cell located around a base station.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 20500
Rec. Value 20500
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Uplink ARFCN setting for the EUTRAN
Neighbor Cell. This information is shared between Base Stations via
X2 messages.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-190 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ECN
Parameter name ECN
Description Whether to use the ECN (Explicit Congestion Notification) function.
- 0: The ECN function does not work on the eNB.
- 1: The ECN function works on the eNB.
Object class & hierarchy PLDGtpInfoFunc
Type Static
Data Type byte
Unit NA
Range 0-1
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-GTP-INF/CHG-GTP-INF
Engineering rules The corresponding parameter is for enabling or disabling the ECN
function in GTP. The ECN (Explicit Congestion Notification) is the
feature that detects backhaul congestion. In the Downlink direction,
it informs the device of backhaul congestion, and in the Uplink
direction, it informs whether the device’s ECN function is enabled
or disabled.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-191


CHAPTER 2. Parameter Description

EMER_AC_UECOUNT
Parameter name EMER_AC_UECOUNT
Description Number of emergency access UEs.
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This is the emergency type call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

EMER_AC_UECOUNT
Parameter name EMER_AC_UECOUNT
Description Number of emergency access UEs.
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules This is the emergency type call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-192 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

EMER_AC_UECOUNT
Parameter name EMER_AC_UECOUNT
Description Number of emergency access UEs.
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules This is the emergency type call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

EMER_AC_UECOUNT
Parameter name EMER_AC_UECOUNT
Description Number of emergency access UEs.
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules This is the emergency type call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-193


CHAPTER 2. Parameter Description

ENB_ID
Parameter name ENB_ID
Description Specifies a base station ID that represents a base station.
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type word32
Unit BIT STRING
Range 0-268435455
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-ENB-INF
Engineering rules In case of Macro eNB, it is indicated in 20 bit, and in case of Home
eNB, it is indicated in 28 bit.
Caution/Note It is entered by the operator when expanding the eNB, and after
entering the value, corresponding ID must be used until further
expansion of the eNB.
Delta NA
Real time change It’s the value entered when expanding the eNB and it cannot be
changed while in operation.
Need to reset No

2-194 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ENB_ID
Parameter name ENB_ID
Description eNB ID representing a neighbor eNB. If the enbType is Macro eNB,
its 20-bit is eNB ID. If the enbType is Home eNB, its 28-bit is eNB ID.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range 0-268435455
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the eNB ID of the Neighbor eNB. Depending
on the Neighbor eNB type, the entry must be made in 20 bit for Macro
eNB ID, and 28 bit for Home eNB. This information is used during X2
Link Setup and Handover.
Caution/Note The eNB ID of the Neighbor eNB must be entered accurately. If the
information does not match, the X2 Link Setup does not work.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-195


CHAPTER 2. Parameter Description

ENB_ID
Parameter name ENB_ID
Description The eNB ID of a base station where a E-UTRAN neighbor cell that is
located around a base station is belonged. If the enbType is Macro
eNB, its 20-bit is eNB ID. If the enbType is Home eNB, its 28-bit is
eNB ID. This is used when a cell Identifier is created.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word32
Unit Static
Range 0-268435455
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the eNB ID of the Neighbor eNB to which
the Neighbor Cell belongs. Depending on the Neighbor eNB type,
the entry must be made in 20 bits for Macro eNB ID, and 28 bits for
Home eNB. This information is used during Handover.
Caution/Note The eNB ID of the Neighbor eNB must be entered accurately. If the
information does not match, the Handover will not execute.
Delta NA
Real time change Yes
Need to reset No

ENB_MCC
Parameter name ENB_MCC[DIGIT]
Description Specifies PLMN information (MCC) representing a base station.
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ Only
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-ENB-INF
Engineering rules MCC: Mobile Country Code
It’s the corresponding Country ID and indicated in 3 digit code.

2-196 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ENB_MCC
Parameter name ENB_MCC
Description PLMN information (MCC) representing a neighbor eNB. Enter 3-digit
number whose each digit range is 0-9.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the MCC (PLMN information) of the
Neighbor eNB. The MCC information must be entered accurately.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-197


CHAPTER 2. Parameter Description

ENB_MCC
Parameter name ENB_MCC
Description The PLMN information (MCC) of a base station where the E-
UTRAN neighbor cell, located around a base station, is belonged.
Enter 3-digit number whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
Neighbor eNB to which the neighboring EUTRAN Cell belongs.
The MCC information must be entered accurately.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-198 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ENB_MNC
Parameter name ENB_MNC[DIGIT]
Description Specifies PLMN information (MNC) representing a base station.
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ Only
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-ENB-INF
Engineering rules MNC: Mobile Network Code
It is the Network Operator ID and is indicated either in a 3 or 2-digit
code.
Caution/Note NA
Delta NA
Real time change It’s the value entered during expansion and cannot be changed
while in operation.
Need to reset No

ENB_MNC
Parameter name ENB_MNC
Description PLMN information (MNC) representing a neighbor eNB. Enter 3-digit
or 2-digit number whose each digit range is 0-9.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the MNC (PLMN information) of the
Neighbor eNB. The MNC information must be entered accurately.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-199


CHAPTER 2. Parameter Description

ENB_MNC
Parameter name ENB_MNC
Description The PLMN information (MNC) of a base station where the E-UTRAN
neighbor cell, located around a base station, is belonged. Enter 3-
digit or 2-digit number whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC (PLMN information) of the
Neighbor eNB. The MNC information must be entered accurately.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-200 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ENB_TYPE
Parameter name ENB_TYPE
Description Specifies base station type information.
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type word32
Unit NA
Range ci_Macro_eNB/ci_Home_eNB
Read/Write READ Only
Default value ci_Macro_eNB
Rec. Value ci_Macro_eNB
Commands RTRV-ENB-INF/CHG-ENB-INF
Engineering rules It’s the parameter that indicates the Base Station type. It is entered
during expansion and cannot be changed while in operation.
- ci_Macro_eNB: Macro eNB
- ci_Home_eNB: Home eNB
Caution/Note NA
Delta NA
Real time change It is the Read Only PLD and cannot be changed while in operation.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-201


CHAPTER 2. Parameter Description

ENB_TYPE
Parameter name ENB_TYPE
Description eNB type of a neighbor eNB
- ci_Macro_eNB: Macro eNB
- ci_Home_eNB: Home eNB
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range ci_Macro_eNB/ci_Home_eNB
Read/Write READ/WRITE
Default value ci_Macro_eNB
Rec. Value ci_Macro_eNB
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the Neighbor eNB type. The value
ci_Macro_eNB signifies Macro eNB, and ci_Home_eNB signifies
Home eNB. This information is used during X2 Link Setup and
Handover.
Caution/Note The Neighbor eNB type must be entered accurately.
Delta NA
Real time change Yes
Need to reset No

2-202 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ENB_TYPE
Parameter name ENB_TYPE
Description Type information of a base station where E-UTRAN neighbor cell
that is located around the base station is belonged.
- ci_Macro_eNB: Macro eNB
- ci_Home_eNB: Home eNB
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word32
Unit NA
Range ci_Macro_eNB/ci_Home_eNB
Read/Write READ/WRITE
Default value ci_Macro_eNB
Rec. Value ci_Macro_eNB
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Neighbor eNB type to which the
neighboring EUTRAN Cell belongs. The value ci_Macro_eNB
signifies Macro eNB, and ci_Home_eNB signifies Home eNB. This
information is used during X2 Link Setup and Handover.
Caution/Note The Neighbor eNB type to which the neighboring EUTRAN Cell
belongs must be entered accurately.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-203


CHAPTER 2. Parameter Description

ERAB_INTERACTION
Parameter name ERAB_INTERACTION
Description Whether to process which procedure if E-RAB procedure and
handover procedure compete with each other.
- 0: Handover is prioritized (Handover Prior).
- 1: E-RAB procedure is prioritized (ERAB Prior).
Object class & hierarchy PLDHandoverOptionInfoFunc
Type Static
Data Type int
Unit NA
Range 0-1
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-HO-OPT/CHG-HO-OPT
Engineering rules Setting is set between Handover and ERAB, based on the order of
priority.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-204 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

ESTIMATION_OPT
Parameter name ESTIMATION_OPT
Description If the expected PRB usage calculation type is 0, it is auto. If 1, it is
manual.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-1
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the parameter that determines the PRB value calculation
method. If the parameter is set to 0, then the calculation is
performed automatically. If it is set to 1, then the manually set
calculation value is used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-205


CHAPTER 2. Parameter Description

2.6 F
FA_INDEX
Parameter name FA_INDEX
Description EUTRA frequency index. Max. 8 FAs can be entered for each cell.
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-CSGPCI-IDLE/CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

FA_INDEX
Parameter name FA_INDEX
Description EUTRA frequency index. Max. 8 FAs can be entered for each cell.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-206 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

FA_INDEX
Parameter name FA_INDEX
Description EUTRA frequency index. Max. 8 FAs can be entered for each cell.
This is mapped to faIndex configured in the PLDEutraFaPriorInfo.
Object class & hierarchy PLDEutranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-PRIOR/CHG-EUTRA-PRIOR
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

FA_INDEX
Parameter name FA_INDEX
Description EUTRA frequency index. Max. 6 FAs can be entered for each cell.
This is mapped to faIndex configured in the PLDEutraFaPriorInfo.
Object class & hierarchy PLDGeranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-5
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-PRIOR/CHG-GERAN-PRIOR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-207


CHAPTER 2. Parameter Description

FA_INDEX
Parameter name FA_INDEX
Description GERAN frequency index. Max. 6 FAs can be entered for each cell.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-5
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

FA_INDEX
Parameter name FA_INDEX
Description Corresponds to the faIndex of EutraFaPriorInfoFunc PLD one to
one. This is used to check the Hybrid PCI range that is configured
in the frequency that is the same as a target cell when judging
inbound handover.
Object class & hierarchy PLDHybridPciInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-HYBRIDPCI-INF/CHG-HYBRIDPCI-INF
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-208 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

FA_INDEX
Parameter name FA_INDEX
Description Index representing the FA information used during Idle Mode Load
Distribution.
Object class & hierarchy PLDIdleModeLbInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-IDLELB-INFO/CHG-IDLELB-INFO
Engineering rules This parameter indicates the FA information used during Idle Mode
Load Distribution. Up to 8 parameters can be registered.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

FA_INDEX
Parameter name FA_INDEX
Description Corresponds to the faIndex of EutraFaPriorInfoFunc PLD one to
one. This is used to check the Open PCI range that is configured in
the frequency that is the same as a target cell when judging
inbound handover.
Object class & hierarchy PLDOpenPciInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-OPENPCI-INF/CHG-OPENPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-209


CHAPTER 2. Parameter Description

FA_INDEX
Parameter name FA_INDEX
Description GERAN frequency index. Max. 6 FAs can be entered for each cell.
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type word32
Unit NA
Range 0-5
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change READ only
Need to reset No

FA_INDEX
Parameter name FA_INDEX
Description GERAN frequency index. Max. 6 FAs can be entered for each cell.
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-5
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-210 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

FA_INDEX
Parameter name FA_INDEX
Description EUTRA frequency index. Max. 6 FAs can be entered for each cell.
This is mapped to faIndex configured in the PLDEutraFaPriorInfo.
Object class & hierarchy PLDUtranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-5
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-UTRA-PRIOR/CHG-UTRA-PRIOR
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

FORCED_MODE
Parameter name FORCED_MODE
Description Whether to set the PLD change regardless of the cell status.
- False: The PLD change is set according to the cell status.
- True: The PLD change is set regardless of the cell status.
Object class & hierarchy PLDCellAccessIdle
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-CAS-IDLE/CHG-CAS-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-211


CHAPTER 2. Parameter Description

FORCED_MODE
Parameter name FORCED_MODE
Description Whether to set the PLD change regardless of the cell status.
- False: The PLD change is set according to the cell status.
- True: The PLD change is set regardless of the cell status.
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-CSGPCI-IDLE/CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

FORCED_MODE
Parameter name FORCED_MODE
Description Whether to set the PLD change regardless of the cell status.
- False: The PLD change is set according to the cell status.
- True: The PLD change is set regardless of the cell status.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-212 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

FORCED_MODE
Parameter name FORCED_MODE
Description Whether to set the PLD change regardless of the cell status.
- False: The PLD change is set according to the cell status.
- True: The PLD change is set regardless of the cell status.
Object class & hierarchy PLDSibSchedulingIdle
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-SIB-IDLE/CHG-SIB-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

FREQUENCY_BAND_INDICATOR
Parameter name FREQUENCY_BAND_INDICATOR
Description Frequency band indicator information for frequency of operating
cell. This information is broadcasted to a UE through SIB 1.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word16
Unit NA
Range 1-64
Read/Write READ/WRITE
Default value 5
Rec. Value 5
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-213


CHAPTER 2. Parameter Description

FWD_END_TIMER
Parameter name FWD_END_TIMER
Description Time duration for which the PDCP layer of a target eNB waits for
End Marker after it receives HO_COMPLETE message.
Object class & hierarchy PLDPdcpInfoFunc
Type Static
Data Type word32
Unit msec
Range 10-1000
Read/Write READ/WRITE
Default value 200
Rec. Value 200
Commands RTRV-PDCP-INF/CHG-PDCP-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-214 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.7 G
GAP_PATTERN_FOR_ANR
Parameter name GAP_PATTERN_FOR_ANR
Description Measurement gap pattern information for SON ANR. The default is
gapPattern0.
- gapPattern0: 0-39.
- gapPattern1: 0-79.
Object class & hierarchy PLDMeasurementGapInfoFunc
Type Static
Data Type enum
Unit NA
Range gapPattern0/gapPattern1
Read/Write READ/WRITE
Default value gapPattern0
Rec. Value gapPattern0
Commands RTRV-MSGAP-INF/CHG-MSGAP-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-215


CHAPTER 2. Parameter Description

GAP_PATTERN_FOR_INTER_FA
Parameter name GAP_PATTERN_FOR_INTER_FA
Description Measurement gap pattern information used for inter-frequency
measurement. The default is gapPattern0.
- gapPattern0: 0-39.
- gapPattern1: 0-79.
Object class & hierarchy PLDMeasurementGapInfoFunc
Type Static
Data Type enum
Unit NA
Range gapPattern0/gapPattern1
Read/Write READ/WRITE
Default value gapPattern0
Rec. Value gapPattern0
Commands RTRV-MSGAP-INF/CHG-MSGAP-INF
Engineering rules The operator can only set this parameter either to gapPattern0 or
gapPattern1. The RRM feature dynamically allocates a gap offset
value to each UE.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-216 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GAP_PATTERN_FOR_INTER_RAT
Parameter name GAP_PATTERN_FOR_INTER_RAT
Description Measurement gap pattern information used for inter-RAT
measurement. The default is gapPattern0.
- gapPattern0: 0-39.
- gapPattern1: 0-79.
Object class & hierarchy PLDMeasurementGapInfoFunc
Type Static
Data Type enum
Unit NA
Range gapPattern0/gapPattern1
Read/Write READ/WRITE
Default value gapPattern0
Rec. Value gapPattern0
Commands RTRV-MSGAP-INF/CHG-MSGAP-INF
Engineering rules The operator can only set this parameter either to gapPattern0 or
gapPattern1. The RRM feature dynamically allocates a gap offset
value to each UE.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-217


CHAPTER 2. Parameter Description

GAP_USE_FOR_ANR
Parameter name GAP_USE_FOR_ANR
Description Whether to use measurement gap for SON ANR function.
The default is 0.
- False: Measurement gap is not used.
- True: Measurement gap is used.
Object class & hierarchy PLDMeasurementGapInfoFunc
Type Static
Data Type BOOL
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-MSGAP-INF/CHG-MSGAP-INF
Engineering rules - If GAP_USE_FOR_ANR is false, AP_PATTERN_FOR_INTER_FA
or GAP_PATTERN_FOR_INTER_RAT is used.
- If GAP_USE_FOR_ANR is true, GAP_PATTERN_FOR_ANR is
used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-218 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN0
Parameter name GERAN_ARFCN0
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range 0-1023
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This is the first value of the ARFCN list used by the corresponding
GERAN FA. Up to 32 ARFCN can be set.
Caution/Note The default setting is 0. If the setting is set to -1, then the system
determines that the corresponding parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-219


CHAPTER 2. Parameter Description

GERAN_ARFCN1
Parameter name GERAN_ARFCN1
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN2
Parameter name GERAN_ARFCN2
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-220 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN3
Parameter name GERAN_ARFCN3
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN4
Parameter name GERAN_ARFCN4
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-221


CHAPTER 2. Parameter Description

GERAN_ARFCN5
Parameter name GERAN_ARFCN5
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN6
Parameter name geranArfcn6
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-222 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN7
Parameter name GERAN_ARFCN7
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN8
Parameter name GERAN_ARFCN8
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-223


CHAPTER 2. Parameter Description

GERAN_ARFCN9
Parameter name GERAN_ARFCN9
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN10
Parameter name GERAN_ARFCN10
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-224 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN11
Parameter name GERAN_ARFCN11
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN12
Parameter name GERAN_ARFCN12
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-225


CHAPTER 2. Parameter Description

GERAN_ARFCN13
Parameter name GERAN_ARFCN13
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN14
Parameter name GERAN_ARFCN14
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-226 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN15
Parameter name GERAN_ARFCN15
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN16
Parameter name GERAN_ARFCN16
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-227


CHAPTER 2. Parameter Description

GERAN_ARFCN17
Parameter name GERAN_ARFCN17
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN18
Parameter name GERAN_ARFCN18
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-228 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN19
Parameter name GERAN_ARFCN19
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN20
Parameter name GERAN_ARFCN20
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-229


CHAPTER 2. Parameter Description

GERAN_ARFCN21
Parameter name GERAN_ARFCN21
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN22
Parameter name GERAN_ARFCN22
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-230 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN23
Parameter name GERAN_ARFCN23
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN24
Parameter name GERAN_ARFCN24
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-231


CHAPTER 2. Parameter Description

GERAN_ARFCN25
Parameter name GERAN_ARFCN25
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN26
Parameter name GERAN_ARFCN26
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-232 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN27
Parameter name GERAN_ARFCN27
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN28
Parameter name GERAN_ARFCN28
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-233


CHAPTER 2. Parameter Description

GERAN_ARFCN29
Parameter name GERAN_ARFCN29
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_ARFCN30
Parameter name GERAN_ARFCN30
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

2-234 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

GERAN_ARFCN31
Parameter name GERAN_ARFCN31
Description ARFCN (Absolute Radio Frequency Channel Number) of GERAN
FA Object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -1-1023
Read/Write READ/WRITE
Default value -1
Rec. Value -1
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules Sets the ARFCN list used by the corresponding GERAN FA.
Caution/Note The default setting is -1, which signifies that the corresponding
parameter is not used.
Delta NA
Real time change Yes
Need to reset No

GERAN_FILTER_COEFFICIENT
Parameter name GERAN_FILTER_COEFFICIENT
Description Measurement filtering coefficient for GERAN.
Object class & hierarchy PLDQuantityConfigGeran
Type Static
Data Type word16
Unit NA
Range 0-14
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-QUANT-GERAN/CHG-QUANT-GERAN
Engineering rules Measurement quantity used for GERAN measurement
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-235


CHAPTER 2. Parameter Description

GROUP_ID
Parameter name GROUP_ID
Description Group ID of a carrier belonging to a cell.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word16
Unit NA
Range 0-10
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-236 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.8 H
HEART_BEAT_INTERVAL
Parameter name HEART_BEAT_INTERVAL
Description The transmission interval of HeartBeat message that is transmitted
to check the validity of SCTP link.
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit msec
Range 100-60000
Read/Write READ/WRITE
Default value 1500
Rec. Value 1500
Commands RTRV-SCTP-PARA/CHG-SCTP-PARA
Engineering rules If the SCTP Connection between two nodes is set, then a
HeartBeat message is transmitted to verify the validity of the SCTP
Link. At this point, the heartBeatInterval is used as the parameter
for determining the transmission interval of the HeartBeat
message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-237


CHAPTER 2. Parameter Description

HEIGHT
Parameter name HEIGHT
Description It is the height information for each Cell.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type char
Unit NA
Range 0-0
Read/Write READ/WRITE
Default value ‘0000.00m’
Rec. Value ‘0000.00m’
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules Altitude of each cell to provide the OTDOA function. The altitude
can be used to calculate the UE location information in a cell.
AAAA.AAm
- AAAA.AA: Sea level altitude. -9999.99m-9999.99m
The unit ‘m’ must be included. ex)‘.85m’
Caution/Note The unit ‘m’ must be included. ex)‘.85m’
Delta NA
Real time change Yes
Need to reset No

2-238 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

HNB_NAME
Parameter name HNB_NAME
Description This is broadcasted to a UE through SIB (System Information
Block) 9 when a cell is operating as a CSG cell or a hybrid cell. Its
unit is byte
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit NA
Range NA
Read/Write READ/WRITE
Default value ‘SAMSUNG_LTE’
Rec. Value ‘SAMSUNG_LTE’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is the name of the Home eNB. When a Cell is operated as a
CSG Cell, or as a Hybrid Cell, it broadcasts to UE via SIB (System
Information Block) 9. The broadcast unit is in bytes.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-239


CHAPTER 2. Parameter Description

H_PRIORITY_AC_UECOUNT
Parameter name H_PRIORITY_AC_UECOUNT
Description Number of high priority access UEs.
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This is the high priority call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

H_PRIORITY_AC_UECOUNT
Parameter name H_PRIORITY_AC_UECOUNT
Description Number of high priority access UEs
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules This is the high priority call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-240 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

H_PRIORITY_AC_UECOUNT
Parameter name H_PRIORITY_AC_UECOUNT
Description Number of high priority access UEs
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules This is the high priority call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

H_PRIORITY_AC_UECOUNT
Parameter name H_PRIORITY_AC_UECOUNT
Description Number of high priority access UEs
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules This is the high priority call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-241


CHAPTER 2. Parameter Description

HYBRID_PCIRANGE
Parameter name HYBRID_PCIRANGE
Description PCI range of a hybrid cell. The range includes the starting value.
Object class & hierarchy PLDHybridPciInfoLogic
Type Static
Data Type word32
Unit NA
Range ci_rangePCI_n4, ci_rangePCI_n8, ci_rangePCI_n12,
ci_rangePCI_n16, ci_rangePCI_n24, ci_rangePCI_n32,
ci_rangePCI_n48, ci_rangePCI_n64, ci_rangePCI_n84,
ci_rangePCI_n96, ci_rangePCI_n128, ci_rangePCI_n168,
ci_rangePCI_n252, ci_rangePCI_n504
Read/Write READ/WRITE
Default value ci_rangePCI_n4
Rec. Value ci_rangePCI_n4
Commands RTRV-HYBRIDPCI-INF/CHG-HYBRIDPCI-INF
Engineering rules This hybrid PCI range parameter can be set to one of the following
values.
ci_rangePCI_n4, ci_rangePCI_n8, ci_rangePCI_n12,
ci_rangePCI_n16, ci_rangePCI_n24, ci_rangePCI_n32,
ci_rangePCI_n48, ci_rangePCI_n64, ci_rangePCI_n84,
ci_rangePCI_n96, ci_rangePCI_n128, ci_rangePCI_n168,
ci_rangePCI_n252, ci_rangePCI_n504
Each number in the parameter values above indicates the number
of consecutive PCIs starting from hybidPCIStart. For example, if
hybridPCIStart is 300 and hybridPCIRange is ci_rangePCI_n4, the
hybrid PCI is 300, 301, 302, or 303.
Caution/Note This PCI range should not be overlapped with the PCI range of
other cells (e.g., macro, open, csg).
Delta NA
Real time change Yes
Need to reset No

2-242 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

HYBRID_PCIRANGE_USAGE
Parameter name HYBRID_PCIRANGE_USAGE
Description Whether to use the PCI range of a hybrid cell.
- CI_no_use: No Use
- CI_use: Use
Object class & hierarchy PLDHybridPciInfoLogic
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-HYBRIDPCI-INF/CHG-HYBRIDPCI-INF
Engineering rules Each of the hybrid PCI usage parameter values indicates:
If the parameter value is CI_no_use, inbound handover is not
performed by using the hybrid PCI. If the parameter value is
CI_use, inbound handover is performed by using the hybrid PCI.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-243


CHAPTER 2. Parameter Description

HYBRID_PCISTART
Parameter name HYBRID_PCISTART
Description PCI start value of a hybrid cell
Object class & hierarchy PLDHybridPciInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-503
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-HYBRIDPCI-INF/CHG-HYBRIDPCI-INF
Engineering rules -
Caution/Note This PCI range should not be overlapped with the PCI range of
other cells (e.g., macro, open, csg).
Delta NA
Real time change Yes
Need to reset No

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for Event A1.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-244 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for Event A2.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-245


CHAPTER 2. Parameter Description

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for Event A3.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-246 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for Event A4.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-247


CHAPTER 2. Parameter Description

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-248 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the trigger entry or leave condition of
GERAN B1 event report.
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-GERAN-B1CNF/CHG-GERAN-B1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-249


CHAPTER 2. Parameter Description

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for GERAN
B2 event report.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-250 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for UTRA
Event B1.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-B1CNF/CHG-UTRA-B1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-251


CHAPTER 2. Parameter Description

HYSTERESIS
Parameter name HYSTERESIS
Description Hysteresis value used in the entry or leave condition for UTRA
Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 0-30
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-252 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.9 I
IDLE_CSFB_OPTIMIZED
Parameter name IDLE_CSFB_OPTIMIZED
Description Whether to simplify call procedure when performing idle status
CSFB procedure.
- False: The CSFB procedure is performed after call procedure is
completed.
- True: The CSFB procedure is performed after simplifying call
procedure.
Object class & hierarchy PLDInterworkControlInfo
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-INTWO-OPT/CHG-INTWO-OPT
Engineering rules This parameter determines whether or not to engage Optimized
CSFB operation (internal resource setting not performed) during
Idle CSFB operation. Optimized CSFB is engaged if it is set to 1.
Caution/Note When setting this parameter while Idle CSFB is in operation, the
internal resource setting procedure is not performed.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-253


CHAPTER 2. Parameter Description

IMS_EMERGENCY_SUPPORT
Parameter name IMS_EMERGENCY_SUPPORT
Description Whether to support emergency call. This information is
broadcasted to a UE through SIB 1.
- False: An operating cell does not support IMS emergency.
- True: An operating cell supports IMS emergency.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-254 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

IND_OFFSET
Parameter name IND_OFFSET
Description Cell individual offset applied to an E-UTRAN neighbor cell that is
located around a base station. This is used for UE measurement in
the RRC connected mode.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit dB
Range ci_dB_24/ci_dB_22/ci_dB_20/ci_dB_18/ci_dB_16/ci_dB_14/
ci_dB_12/ci_dB_10/ci_dB_8/ci_dB_6/ci_dB_5/ci_dB_4/ci_dB_3/
ci_dB_2/ci_dB_1/ci_dB0/ci_dB1/ci_dB2/ci_dB3/ci_dB4/ci_dB5/
ci_dB6/ci_dB8/ci_dB10/ci_dB12/ci_dB14/ci_dB16/ci_dB18/
ci_dB20/ci_dB22/ci_dB24
Read/Write READ/WRITE
Default value ci_dB0
Rec. Value ci_dB0
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-
EUTRAN/DLT-NBR-EUTRAN
Engineering rules This parameter indicates the individual Offset value of the
neighboring EUTRAN Cell. Accurately set the parameter because
this value is used by a device while taking measurements.
ci_dB_24 = 0, /* display_name: ‘ci_dB-24’ */
ci_dB_22 = 1, /* display_name: ‘ci_dB-22’ */
ci_dB_20 = 2, /* display_name: ‘ci_dB-20’ */
ci_dB_18 = 3, /* display_name: ‘ci_dB-18’ */
ci_dB_16 = 4, /* display_name: ‘ci_dB-16’ */
ci_dB_14 = 5, /* display_name: ‘ci_dB-14’ */
ci_dB_12 = 6, /* display_name: ‘ci_dB-12’ */
ci_dB_10 = 7, /* display_name: ‘ci_dB-10’ */
ci_dB_8 = 8, /* display_name: ‘ci_dB-8’ */
ci_dB_6 = 9, /* display_name: ‘ci_dB-6’ */
ci_dB_5 = 10, /* display_name: ‘ci_dB-5’ */
ci_dB_4 = 11, /* display_name: ‘ci_dB-4’ */
ci_dB_3 = 12, /* display_name: ‘ci_dB-3’ */
ci_dB_2 = 13, /* display_name: ‘ci_dB-2’ */
ci_dB_1 = 14, /* display_name: ‘ci_dB-1’ */
ci_dB0 = 15,
ci_dB1 = 16,
ci_dB2 = 17,
ci_dB3 = 18,
ci_dB4 = 19,
ci_dB5 = 20,
ci_dB6 = 21,

© SAMSUNG Electronics Co., Ltd. 2-255


CHAPTER 2. Parameter Description

(Continued)

Engineering rules ci_dB8 = 22,


ci_dB10 = 23,
ci_dB12 = 24,
ci_dB14 = 25,
ci_dB16 = 26,
ci_dB18 = 27,
ci_dB20 = 28,
ci_dB22 = 29,
ci_dB24 = 30
Caution/Note This value is used by a device when taking measurements so
accurately set the value.
Delta NA
Real time change Yes
Need to reset No

2-256 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTEGRITY_EA_PRIOR
Parameter name INTEGRITY_EA_PRIOR
Description Integrity Protection algorithm information that is supported by a
base station
- EIA0: NULL.
- EIA1: SNOW 3G.
- EIA2: AES.
Object class & hierarchy PLDSecurityInfoFunc
Type Static
Data Type word32
Unit NA
Range EIA0/EIA1/EIA2
Read/Write READ/WRITE
Default value EIA1
Rec. Value EIA1
Commands RTRV-SECU-INF/CHG-SECU-INF
Engineering rules This is the Integrity Protection algorithm information, supported by
a Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-257


CHAPTER 2. Parameter Description

INTER_FREQ_REDIRECTION
Parameter name INTER_FREQ_REDIRECTION
Description Whether to perform forced redirection during Inter-frequency
handover
- False: There is no redirection during handover (Normal).
- True: Redirection is performed at any condition (Force Used).
Object class & hierarchy PLDInterworkControlInfo
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-INTWO-OPT/CHG-INTWO-OPT
Engineering rules This parameter determines whether to perform Handover or
Redirection during Inter Frequency Handover. If it is set to False,
normal Inter FA Handover is performed. If it is set to True, then
Redirection is performed.
Caution/Note The system performs either Handover or Redirection, based on the
setting, so it must be set accurately.
Delta NA
Real time change Yes
Need to reset No

2-258 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_BUFFER_FLUSH
Parameter name INTERNAL_BUFFER_FLUSH
Description Waiting time after sending the buffer flush message to perform
buffer flush of PDCP entity after receiving UEContextRelease (X2),
UEContextReleaseCommand (S1) during handover.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value inside the Base Station for operating PDCP
and buffer flush.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-259


CHAPTER 2. Parameter Description

INTERNAL_DATA_FORWARD_END_IND
Parameter name INTERNAL_DATA_FORWARD_END_IND
Description Waiting time to receive DataForwardEndInd that confirms
DataForwarding from PDCP entity is completed after sending
UEContextRelease to X2 and also sending HandoverNotify to S1
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for receiving a message from PDCB that Data
Forwarding has completed during the Handover process.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-260 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_DATA_TRANSFER_START
Parameter name INTERNAL_DATA_TRANSFER_START
Description Waiting time for a reply after sending control message that notifies
HandoverComplete to the PDCP entity at the target side after X2,
S1 handover
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer that receives a notification from the PDCB that
Data Transfer will start because the Handover process is complete.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-261


CHAPTER 2. Parameter Description

INTERNAL_ENB_RESET
Parameter name INTERNAL_ENB_RESET
Description Waiting time for a reply after sending CallDelete message to
internal entities to release the internal entities in a base station
during base station reset
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This timer sends a call disconnect message to the internal block of
a Base Station. The Base Station then executes the internal Reset
process in response to the call disconnect, then replies back to the
timer.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-262 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_FORWARDING_PATH_SETUP
Parameter name INTERNAL_FORWARDING_PATH_SETUP
Description Waiting time for a reply after sending setup message to the GTP
entity to set up uplink and downlink paths during handover
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for receiving a response after transmitting a
message to GTP for UL, DL, and GTP during Handover.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-263


CHAPTER 2. Parameter Description

INTERNAL_NO_WAIT_RETRY
Parameter name INTERNAL_NO_WAIT_RETRY
Description Waiting time to resend a message to S1 or X2 if there is no timer
information when receiving a Failure message (S1SetupFailure,
X2SetupFailure, S1EnbConfigurationUpdateFailure,
X2EnbConfigurationUpdateFailure) from S1 or X2.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer within a Base Station that activates if there is no
Time to Wait value in the Failure message transmitted from MME
or another Base Station.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-264 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_REESTABLSH_TIME_TO_WAIT
Parameter name INTERNAL_REESTABLSH_TIME_TO_WAIT
Description Waiting time to receive RrcReestablishRequest from a UE after
receiving Max Retransmission Ind from MACB, RLF or RLCB
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for standby until a device comes In Sync, in case
the device and a Base Station is Out Of Sync. Signal is
disconnected once the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-265


CHAPTER 2. Parameter Description

INTERNAL_REESTALISH_CONTROL
Parameter name INTERNAL_REESTALISH_CONTROL
Description Waiting time for a reply after sending a control message to control
the internal entities in a base station during Reestablish
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for receiving a response after transmitting a
message to internal block, Reestablishment of a Base Station,
during the Reestablishment process.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-266 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_RESOURCE_RELEASE
Parameter name INTERNAL_RESOURCE_RELEASE
Description Waiting time for a reply after sending a release message to the
internal entities (PDCB, MACB, RLCB) to release the internal
resources in a base station
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer that waits for a response message after notifying
internal blocks of a call disconnection.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-267


CHAPTER 2. Parameter Description

INTERNAL_RESOURCE_SETUP
Parameter name INTERNAL_RESOURCE_SETUP
Description Waiting time for a reply after sending a setup message to the
internal entities (PDCB, MACB, RLCB) to set up the internal
resources in a base station
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for receiving a response message after sending a
setup message to the internal block SRB or DRB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-268 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_RRC_DATA_TRANSFER
Parameter name INTERNAL_RRC_DATA_TRANSFER
Description Waiting time to receive data transfer confirm message from the
PDCP entity after sending RrcConnectionReconfiguration to a UE
during intra cell handover.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 40
Rec. Value 40
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules It is recommended to use the default value which is optimized for
the eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-269


CHAPTER 2. Parameter Description

INTERNAL_RRC_RESET
Parameter name INTERNAL_RRC_RESET
Description Waiting time until UEs are released after sending the
RrcConnectionRelease message to multiple UEs during base
station reset.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules It is recommended to use the default value which is optimized for
the eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-270 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_RTDINFO_REQ
Parameter name INTERNAL_RTDINFO_REQ
Description Waiting time to receive the RTDInfoCnf message after sending
RTDInfoReq to MAC to acquire RTD information.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 100
Rec. Value 100
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules It is recommended to use the default value which is optimized for
the eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-271


CHAPTER 2. Parameter Description

INTERNAL_SECURITY_CONTROL
Parameter name INTERNAL_SECURITY_CONTROL
Description Waiting time for a reply after sending a control message to the
PDCP entity for internal security control in a base station.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules It is recommended to use the default value which is optimized for
the eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-272 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_SIGNALING_INACTIVITY
Parameter name INTERNAL_SIGNALING_INACTIVITY
Description Signaling inactivity time that is triggered when there is no signaling
message for a certain period of time.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit sec
Range 0-65535
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for determining signal inactivity. If there is no RRC
message that includes NAS information within 10 seconds of
activating the timer after Attach, the Base Station deactivates the
timer. The timer is reactivated if a RRC message that includes NAS
information is received/transmitted within 10 seconds.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-273


CHAPTER 2. Parameter Description

INTERNAL_SOLICIT_MEASUREMENT_REPORT
Parameter name INTERNAL_SOLICIT_MEASUREMENT_REPORT
Description Waiting time to receive the Measurement Report message from a
UE according to the Solicit Measurement Report procedure.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules It is recommended to use the default value which is optimized for
the eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-274 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_SUB_CELL_CHANGE
Parameter name INTERNAL_SUB_CELL_CHANGE
Description Waiting time for a reply after sending
msgCmacPhySubCellChangeCnf to MAC in a base station that is a
subcell configuration.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 1000
Rec. Value 1000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is a timer only for Base Station formation with a SubCell.
The timer is for notifying MAC of the switching SubCell, and for
receiving a response message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-275


CHAPTER 2. Parameter Description

INTERNAL_SUB_CELL_PDCP_CONTROL
Parameter name INTERNAL_SUB_CELL_PDCP_CONTROL
Description Waiting time for a reply after sending msgCpdcpControl to PDCP in
a base station that is a subcell configuration.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 1000
Rec. Value 1000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is a timer only for Base Station formation with a SubCell.
The timer is for notifying PDCP of the switching SubCell, and for
receiving a response message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-276 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTERNAL_USER_INACTIVITY
Parameter name INTERNAL_USER_INACTIVITY
Description Time when user inactivity is started by MAC because there is no
traffic with an attached UE for a certain period of time.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit sec
Range 0-65535
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the User Data Inactivity timer.
It is activated in MAC, and deactivates if there is no data within 10
seconds.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-277


CHAPTER 2. Parameter Description

INTER_RAT_CS_REDIRECTION
Parameter name INTER_RAT_CS_REDIRECTION
Description Whether to perform forced redirection during CSFB with inter RAT
handover.
- False: There is no redirection during handover (Normal).
- True: Redirection is performed at any condition (Force Used).
Object class & hierarchy PLDInterworkControlInfo
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-INTWO-OPT/CHG-INTWO-OPT
Engineering rules This parameter determines whether to perform CSFB with PS
Handover or Redirection, during CSFB operations. If it is set to
False, normal CSFB with PS Handover is performed. If it is set to
True, then Redirection is performed.
Caution/Note The system performs CSFB with PS Handover or Redirection,
based on the setting, so it must be set accurately.
Delta NA
Real time change Yes
Need to reset No

2-278 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

INTER_RAT_PS_REDIRECTION
Parameter name INTER_RAT_PS_REDIRECTION
Description Whether to perform forced redirection during Inter RAT handover
- False: There is no redirection during handover (Normal).
- True: Redirection is performed at any condition (Force Used).
Object class & hierarchy PLDInterworkControlInfo
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-INTWO-OPT/CHG-INTWO-OPT
Engineering rules This parameter determines whether to perform Handover or
Redirection during Inter RAT PS Handover. If it is set to False,
normal Inter RAT PS Handover is performed. If it is set to True,
then Redirection is performed.
Caution/Note The system performs either Inter RAT PS Handover or Redirection,
based on the setting, so it must be set accurately.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-279


CHAPTER 2. Parameter Description

INTRA_FREQ_CELL_RESELECT
Parameter name INTRA_FREQ_CELL_RESELECT
Description Reselection of an intra frequency cell when a cell selected by a UE
is barred
- ci_intraFreqReselect_allowed: An intra frequency cell is
reselected.
- ci_intraFreqReselect_notAllowed: It is assumed an intra
frequency cell is barred.
Object class & hierarchy PLDCellAccessInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_intraFreqReselect_allowed/ci_intraFreqReselect_notAllowed
Read/Write READ/WRITE
Default value ci_intraFreqReselect_notAllowed
Rec. Value ci_intraFreqReselect_notAllowed
Commands RTRV-CELL-ACS/CHG-CELL-ACS
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-280 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

IP_VER
Parameter name IP_VER
Description IP address version of a server that will collect CSL data (IPV4,
IPV6).
Object class & hierarchy PLDCslInfo
Type Static
Data Type word32
Unit NA
Range IPV4/IPV6
Read/Write READ/WRITE
Default value IPV4
Rec. Value IPV4
Commands RTRV-CSL-INF/CHG-CSL-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

IP_VER
Parameter name IP_VER
Description IP address version indicating the IP address of a neighboring eNB.
- IPV4: Indicates IPV4 address
- IPV6: Indicates IPV6 address
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range IPV4/IPV6
Read/Write READ/WRITE
Default value IPV4
Rec. Value IPV4
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This indicates the IP Version information of the neighboring ENB.
All neighboring eNB IP Version information must be the same.
Caution/Note All neighboring eNB IP Version information must be the same.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-281


CHAPTER 2. Parameter Description

IP_VER
Parameter name IP_VER
Description MME IP address version. Whether IP version is either IPv4 or IPv6.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type word32
Unit NA
Range IPV4/IPV6
Read/Write READ/WRITE
Default value IPV4
Rec. Value IPV4
Commands RTRV-MME-CONF/CHG-MME-CONF
Engineering rules - IPV4: It is set when using the IPV4 as the IP Address of MME.
- IPV6: It is set when using the IPV6 as the IP Address of MME.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-282 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

IS_HOALLOWED
Parameter name IS_HOALLOWED
Description Whether to perform handover to the E-UTRAN neighboring cell
- False: Handover is not allowed.
- True: Handover is allowed.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-
EUTRAN/DLT-NBR-EUTRAN
Engineering rules This parameter determines whether or not to execute Handover
with the neighboring EUTRAN Cell. If it is set to False, then
Handover is not executed. If it is set to True, then Handover is
performed.
Caution/Note Handover is not executed if it is set to FALSE, so ensure the
setting is accurate.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-283


CHAPTER 2. Parameter Description

IS_HOALLOWED
Parameter name IS_HOALLOWED
Description Whether to perform handover to the GERAN neighbor cell
- False: Handover is not allowed.
- True: Handover is allowed.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter determines whether or not to execute Handover
with the neighboring GERAN Cell. If it is set to False, then
Handover is not executed. If it is set to True, then Handover is
performed.
Caution/Note Handover is not executed if it is set to FALSE, so ensure the
setting is accurate.
Delta NA
Real time change Yes
Need to reset No

2-284 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

IS_HOALLOWED
Parameter name IS_HOALLOWED
Description Whether to perform handover to the UTRAN neighbor cell
- False: Handover is not allowed.
- True: Handover is allowed.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter determines execution of Handover with the
Neighboring UTRAN Cell. If the parameter is False, Handover is
not executed, and if the parameter is True, Handover is executed.
Caution/Note Be sure to accurately set the parameter since Handover is not
executed if the setting is set to FALSE.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-285


CHAPTER 2. Parameter Description

IS_REMOVE_ALLOWED
Parameter name IS_REMOVE_ALLOWED
Description Whether neighbor relation deletion is allowed in a cell of a base
station using the ANR (Automatic Neighbor Relation) function.
- True: A neighbor cell can be deleted.
- False: A neighbor cell cannot be deleted.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter determines whether or not deletion by the ANR of
the neighboring EUTRAN Cell is possible. If it is False, then the
target cannot be deleted. If it is True, the target can be deleted.
Caution/Note If it is set to TRUE, the target can be deleted, so ensure the setting
is accurate.
Delta NA
Real time change Yes
Need to reset No

2-286 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

IS_REMOVE_ALLOWED
Parameter name IS_REMOVE_ALLOWED
Description Whether neighbor relation deletion is allowed in a cell of a base
station using the ANR (Automatic Neighbor Relation) function
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter determines whether or not deletion by the ANR of
the neighboring GERAN Cell is possible. If it is False, then the
target cannot be deleted. If it is True, the target can be deleted.
Caution/Note If it is set to TRUE, the target can be deleted, so en sure the setting
is accurate.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-287


CHAPTER 2. Parameter Description

IS_REMOVE_ALLOWED
Parameter name IS_REMOVE_ALLOWED
Description Whether neighbor relation deletion is allowed in a cell of a base
station using the ANR (Automatic Neighbor Relation) function-
True: A neighbor cell can be deleted.
- False: A neighbor cell cannot be deleted.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter determines whether or not deletion by the ANR of
the neighboring UTRAN Cell is possible. If it is False, then the
target cannot be deleted. If it is True, the target can be deleted.
Caution/Note If it is set to True, the target can be deleted, so ensure the setting is
accurate.
Delta NA
Real time change Yes
Need to reset No

2-288 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.10 J
2.11 K
KEEP_ALIVE
Parameter name KEEP_ALIVE
Description Whether to send GTP ECHO-REQ message periodically (Keep
Alive).
- 0: ECHO-REQ message is not sent.
- 1: ECHO-REQ message is sent (default).
Object class & hierarchy PLDGtpInfoFunc
Type Static
Data Type byte
Unit NA
Range 0-1
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-GTP-INF/CHG-GTP-INF
Engineering rules The corresponding parameter is for setting whether or not to
transmit GTP Echo Request.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-289


CHAPTER 2. Parameter Description

2.12 L
LAC
Parameter name LAC
Description Location Area Code of a GERAN neighbor cell that is located
around a base station
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the Location Area Code of the GERAN
neighboring Cell. This information is used during RIM operation
and Handover.
Caution/Note Accurately set the information to ensure successful RIM operation
and Handover.
Delta NA
Real time change Yes
Need to reset No

2-290 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

LAC
Parameter name LAC
Description Location Area Code of a UTRAN neighbor cell that is located
around a base station
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the Location Area Code of the UTRAN
neighboring Cell. This information is used during RIM operation
and Handover.
Caution/Note Accurately set the information to ensure successful RIM operation
and Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-291


CHAPTER 2. Parameter Description

LATITUDE
Parameter name LATITUDE
Description It is the latitude information of each Cell.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type char
Unit NA
Range NA
Read/Write READ/WRITE
Default value ‘N 000:00:00.000’
Rec. Value ‘N 000:00:00.000’
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules Latitude of each cell to provide the OTDOA function. The latitude
can be used to calculate the UE location information in a cell.
A BBB:CC:DD.DDD
- A: Hemisphere. ‘N’ or ‘S’
- BBB: Degree. 0-90
- CC: Minutes. 0-59
- DD.DDD: Milliseconds. 00.000-59.999
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-292 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

LONGITUDE
Parameter name LONGITUDE
Description It is the longitude information of each Cell.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type char
Unit NA
Range NA
Read/Write READ/WRITE
Default value ‘E 000:00:00.000’
Rec. Value ‘E 000:00:00.000’
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules Longitude of each cell to provide the OTDOA function.
The longitude can be used to calculate the UE location information
in a cell.
A BBB:CC:DD.DDD
- A: Hemisphere. ‘E’ or ‘W’
- BBB: Degree. 0-180
- CC: Minutes. 0-59
- DD.DDD: Milliseconds. 00.000-59.999
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-293


CHAPTER 2. Parameter Description

2.13 M
MAX_CALL_COUNT
Parameter name MAX_CALL_COUNT
Description Call count limit for capacity based CAC (Call Admission Control)
per cell. Call count that can be accepted by a cell.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-600
Read/Write READ/WRITE
Default value 600
Rec. Value 600
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This indicates the call count max value in a Cell. This value cannot
be exceeded within the Cell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-294 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_CALL_COUNT
Parameter name MAX_CALL_COUNT
Description Call count limit for capacity based CAC (Call Admission Control)
per server. Call count that can be accepted by a server.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word32
Unit NA
Range 0-21600
Read/Write READ/WRITE
Default value 21600
Rec. Value 21600
Commands RTRV-SVR-CAC/CHG-SVR-CAC
Engineering rules This is the total User number allowed to be connected to the
corresponding server.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-295


CHAPTER 2. Parameter Description

MAX_CONTEXT_SESSION
Parameter MAX_CONTEXT_SESSION
name
Description Number of ROHC max context sessions that is supported per call.
- ci_maxROHC_Sessions_cs2: Max. 2 sessions are supported per cell.
- ci_maxROHC_Sessions_cs4: Max. 4 sessions are supported per cell.
- ci_maxROHC_Sessions_cs8: Max. 8 sessions are supported per cell.
- ci_maxROHC_Sessions_cs12: Max. 12 sessions are supported per cell.
- ci_maxROHC_Sessions_cs16: Max. 16 sessions are supported per cell.
- ci_maxROHC_Sessions_cs24: Max. 24 sessions are supported per cell.
- ci_maxROHC_Sessions_cs32: Max. 32 sessions are supported per cell.
- ci_maxROHC_Sessions_cs48: Max. 48 sessions are supported per cell.
- ci_maxROHC_Sessions_cs64: Max. 64 sessions are supported per cell.
- ci_maxROHC_Sessions_cs128: Max. 128 sessions are supported per cell.
- ci_maxROHC_Sessions_cs256: Max. 256 sessions are supported per cell.
- ci_maxROHC_Sessions_cs512: Max. 512 sessions are supported per cell.
- ci_maxROHC_Sessions_cs1024: Max. 1024 sessions are supported per cell.
- ci_maxROHC_Sessions_cs16384: Max. 16384 sessions are supported per cell.
Object class PLDRohcInfoFunc
& hierarchy
Type Static
Data Type word32
Unit NA
Range ci_maxROHC_Sessions_cs2/ci_maxROHC_Sessions_cs4/
ci_maxROHC_Sessions_cs8/ci_maxROHC_Sessions_cs12/
ci_maxROHC_Sessions_cs16/ci_maxROHC_Sessions_cs24/
ci_maxROHC_Sessions_cs32/ci_maxROHC_Sessions_cs48/
ci_maxROHC_Sessions_cs64/ci_maxROHC_Sessions_cs128/
ci_maxROHC_Sessions_cs256/ci_maxROHC_Sessions_cs512/
ci_maxROHC_Sessions_cs1024/ci_maxROHC_Sessions_cs16384
Read/Write READ/WRITE
Default value ci_maxROHC_Sessions_cs16
Rec. Value ci_maxROHC_Sessions_cs16
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering This is the number of ROHC Max context session supported for each CALL.
rules
Caution/Note NA
Delta NA
Real time Yes
change
Need to reset No

2-296 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_DRB_COUNT
Parameter name MAX_DRB_COUNT
Description Number limit of E-RAB (E-UTRAN Radio Access Bearer) for
capacity based CAC (Call Admission Control) per cell. Number of
E-RAB (E-UTRAN Radio Access Bearer) that can be accepted by a
cell.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-1200
Read/Write READ/WRITE
Default value 1200
Rec. Value 1200
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the DRB max value used for DRB count CAC. The DRB
count within a Cell cannot exceed this value.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-297


CHAPTER 2. Parameter Description

MAX_DRB_COUNT
Parameter name MAX_DRB_COUNT
Description Number limit of E-RAB (E-UTRAN Radio Access Bearer) for
capacity based CAC (Call Admission Control) per server. Number
of E-RAB (E-UTRAN Radio Access Bearer) that can be accepted
by a server.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word32
Unit NA
Range 0-43200
Read/Write READ/WRITE
Default value 43200
Rec. Value 43200
Commands RTRV-SVR-CAC/CHG-SVR-CAC
Engineering rules This is the maximum Call Count that can be processed by the
server. CAC process is engaged if the max Call Count is exceeded.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-298 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_ENB_CALL_COUNT
Parameter name MAX_ENB_CALL_COUNT
Description Number limit of capacity based CAC (Call Admission Control) per
base station. Call count that can be accepted by a base station.
Object class & hierarchy PLDEnbCacInfoFunc
Type Static
Data Type word32
Unit NA
Range 0 -4500
Read/Write READ/WRITE
Default value 4500
Rec. Value 4500
Commands RTRV-ENB-CAC/CHG-ENB-CAC
Engineering rules This is the maximum Call Count that can be processed by the eNB.
CAC process is engaged if the max Call Count is exceeded.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-299


CHAPTER 2. Parameter Description

MAX_NUMOF_UEID
Parameter name MAX_NUMOF_UEID
Description Max. number of IMSI or S-TMSI mapping tables to be saved in a
base station for diagnosis call function. This information is valid per
cell.
Object class & hierarchy PLDDiagCallConf
Type Static
Data Type word16
Unit Count
Range 1-30
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-DIAG-CONF, CHG-DIAG-CONF
Engineering rules It is the data that indicates the number of the device buffer for
diagnosis signal feature. A Base Station can store from 1 to 30
device information.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-300 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_PACKED_SI_SIZE
Parameter name MAX_PACKED_SI_SIZE
Description This is the max size of the packed SI that can be transmitted from
the Cell.
Object class & hierarchy PLDSibSchedulingIdle
Type Static
Data Type word32
Unit NA
Range 0-217
Read/Write READ/WRITE
Default value 217
Rec. Value 217
Commands RTRV-SIB-IDLE/CHG-SIB-IDLE
Engineering rules This must be decided by considering the number of DL RB per
bandwidth, max. number of RBs that can be allocated to a single SI
message, the number of PDSCH REs per RB, payload size of DCI
Format 1A, max. aggregation level, and PDCCH coderate, etc.
The recommendation is 9 for 1.4 Mbyte, 26 for 3 Mbyte, 49 for
5 Mbyte, 97 for 10 Mbyte, 141 for 15 Mbyte, and 217 for 20 Mbyte.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-301


CHAPTER 2. Parameter Description

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for Event
A1.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 8
Rec. Value 8
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules This parameter specifies the maximum number of cells that can be
included in a single message (i.e. Measurement Report) when a
device is reporting the measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-302 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for Event
A2.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 8
Rec. Value 8
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules This parameter specifies the maximum number of cells that can be
included in a single message (i.e. Measurement Report) when a
device is reporting the measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-303


CHAPTER 2. Parameter Description

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for Event
A3.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 8
Rec. Value 8
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules This parameter specifies the maximum number of cells that can be
included in a single message (i.e. Measurement Report) when a
device is reporting the measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-304 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for Event
A4.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 8
Rec. Value 8
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules This parameter specifies the maximum number of cells that can be
included in a single message (i.e. Measurement Report) when a
device is reporting the measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-305


CHAPTER 2. Parameter Description

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for Event
A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 8
Rec. Value 8
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules This parameter specifies the maximum number of cells that can be
included in a single message (i.e. Measurement Report) when a
device is reporting the measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-306 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for
EUTRA periodic report.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-EUTRA-PRD/CHG-EUTRA-PRD
Engineering rules This parameter specifies the maximum number of cells that can be
included in a single message (i.e. Measurement Report) when a
device is reporting the measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-307


CHAPTER 2. Parameter Description

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells that can be sent by a UE for measurement
report (GERAN B1 event report).
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-GERAN-B1CNF/CHG-GERAN-B1CNF
Engineering rules This parameter specifies the maximum number of Cells that can be
included in a single message (i.e.: Measurement Report) when a
device is reporting the measurement results.
When applying the new value to the active UEs during the
parameter change, it may cause system overload so the
application of the changed parameter is done when a new
connection request (Attach or Idle to Active) is received from a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-308 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells that can be sent by a UE for measurement
report (GERAN B2 event report).
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules This parameter specifies the maximum number of Cells that can be
included in a single message (i.e.: Measurement Report) when a
device is reporting the measurement results.
When applying the new value to the active UEs during the
parameter change, it may cause system overload so the
application of the changed parameter is done when a new
connection request (Attach or Idle to Active) is received from a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-309


CHAPTER 2. Parameter Description

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells that can be included in measurement report
(GERAN periodic event report).
Object class & hierarchy PLDGeranPeriodicInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-GERAN-PRD/CHG-GERAN-PRD
Engineering rules This parameter specifies the maximum number of Cells that can be
included in a single message (i.e.: Measurement Report) when a
device is reporting the measurement results.
When applying the new value to the active UEs during the
parameter change, it may cause system overload so the
application of the changed parameter is done when a new
connection request (Attach or Idle to Active) is received from a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-310 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for UTRA
Event B1.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-UTRA-B1CNF/CHG-UTRA-B1CNF
Engineering rules This parameter specifies the maximum number of Cells that can be
included in a single message (i.e.: Measurement Report) when a
device is reporting the measurement results.
When applying the new value to the active UEs during the
parameter change, it may cause system overload so the
application of the changed parameter is done when a new
connection request (Attach or Idle to Active) is received from a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-311


CHAPTER 2. Parameter Description

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for UTRA
Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules This parameter specifies the maximum number of Cells that can be
included in a single message (i.e.: Measurement Report) when a
device is reporting the measurement results.
When applying the new value to the active UEs during the
parameter change, it may cause system overload so the
application of the changed parameter is done when a new
connection request (Attach or Idle to Active) is received from a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-312 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MAX_REPORT_CELL
Parameter name MAX_REPORT_CELL
Description Max. number of cells included in the measurement report for UTRA
periodic report.
Object class & hierarchy PLDUtraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-UTRA-PRD/CHG-UTRA-PRD
Engineering rules This parameter specifies the maximum number of Cells that can be
included in a single message (i.e.: Measurement Report) when a
device is reporting the measurement results.
When applying the new value to the active UEs during the
parameter change, it may cause system overload so the
application of the changed parameter is done when a new
connection request (Attach or Idle to Active) is received from a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-313


CHAPTER 2. Parameter Description

MCC
Parameter name MCC
Description The PLMN information (MCC) of a GERAN neighbor cell located
around a base station, Enter 3-digit number whose each digit range
is 0-9.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the MCC of the GERAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the information to ensure successful RIM operation
and Handover.
Delta NA
Real time change Yes
Need to reset No

2-314 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC0
Parameter name MCC0
Description MCC (Mobile Country Code) comprising PLMN (Public Land
Mobile Network). FA has the Preference0 for PLMN #0.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the first Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-315


CHAPTER 2. Parameter Description

MCC0
Parameter name MCC0
Description MCC (Mobile Country Code) comprising PLMN (Public Land
Mobile Network). This is broadcasted to a UE through SIB 1 when
a cell is operating. Total 6 PLMN lists are transmitted. Enter the
MCC value of PLMN #0 that is one out of the six.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating.
Total 6 PLMN lists are transmitted. Enter the MCC value of PLMN
#0 that is one out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-316 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC0
Parameter name MCC0
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC of the EUTRAN neighboring Cell.
This information is used during Handover.
Caution/Note Accurately set the information to ensure successful Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-317


CHAPTER 2. Parameter Description

MCC0
Parameter name MCC0
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MCC’
Rec. Value ‘DIGIT_MCC’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MCC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the information to ensure successful RIM operation
and Handover.
Delta NA
Real time change Yes
Need to reset No

2-318 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC1
Parameter name MCC1
Description MCC (Mobile Country Code) comprising PLMN (Public Land
Mobile Network). FA has the Preference1 for PLMN #1.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type Char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the second Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-319


CHAPTER 2. Parameter Description

MCC1
Parameter name MCC1
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating,
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #1 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-320 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC1
Parameter name MCC1
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
EUTRAN neighboring Cell. This information is used during
Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-321


CHAPTER 2. Parameter Description

MCC1
Parameter name MCC1
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MCC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the information to ensure successful RIM operation
and Handover.
Delta NA
Real time change Yes
Need to reset No

2-322 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC2
Parameter name mcc2[4]
Description MCC (Mobile Country Code) comprising PLMN (Public Land
Mobile Network). FA has the Preference2 for PLMN #2.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the third Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-323


CHAPTER 2. Parameter Description

MCC2
Parameter name MCC2
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating,
Total 6 PLMN lists are transmitted. Enter the MCC value of PLMN
#2 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-324 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC2
Parameter name MCC2
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
EUTRAN neighboring Cell. This information is used during
Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-325


CHAPTER 2. Parameter Description

MCC2
Parameter name MCC2
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
UTRAN neighboring Cell. This information is used during
Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-326 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC3
Parameter name MCC3
Description MCC (Mobile Country Code) comprising PLMN (Public Land
Mobile Network). FA has the Preference3 for PLMN #3.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the fourth Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-327


CHAPTER 2. Parameter Description

MCC3
Parameter name MCC3
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating,
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #3 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-328 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC3
Parameter name MCC3
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
EUTRAN neighboring Cell. This information is used during
Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-329


CHAPTER 2. Parameter Description

MCC3
Parameter name MCC3
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
UTRAN neighboring Cell. This information is used during RIM
operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-330 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC4
Parameter name MCC4
Description MCC (Mobile Country Code) comprising PLMN (Public Land Mobile
Network). FA has the Preference4 for PLMN #4.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the fifth Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-331


CHAPTER 2. Parameter Description

MCC4
Parameter name MCC4
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating.
Total 6 PLMN lists are transmitted. Enter the MCC value of PLMN
#4 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-332 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC4
Parameter name MCC4
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-
EUTRAN/DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
EUTRAN neighboring Cell. This information is used during
Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-333


CHAPTER 2. Parameter Description

MCC4
Parameter name MCC4
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
UTRAN neighboring Cell. This information is used during RIM
operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-334 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC5
Parameter name MCC5
Description MCC (Mobile Country Code) comprising PLMN (Public Land
Mobile Network). FA has the Preference5 for PLMN #5.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the 6th Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-335


CHAPTER 2. Parameter Description

MCC5
Parameter name MCC5
Description MCC (Mobile Country Code) comprising PLMN.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating.
Total 6 PLMN lists are transmitted. Enter the MCC value of PLMN
#5 that is one out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-336 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MCC5
Parameter name MCC5
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
EUTRAN neighboring Cell. This information is used during
Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-337


CHAPTER 2. Parameter Description

MCC5
Parameter name MCC5
Description The PLMN list information (MCC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MCC (PLMN information) of the
UTRAN neighboring Cell. This information is used during RIM
operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-338 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MEAS_QUANTITY_UTRA_FDD
Parameter name MEAS_QUANTITY_UTRA_FDD
Description Measurement quantity information for UTRA FDD measurement.
It is set to either cpich_RSCP or cpich_EcN0.
Object class & hierarchy PLDQuantityConfigUtra
Type Static
Data Type word16
Unit NA
Range ci_cpich_RSCP/ci_cpich_EcN0
Read/Write READ/WRITE
Default value ci_cpich_RSCP
Rec. Value ci_cpich_RSCP
Commands RTRV-QUANT-UTRA/CHG-QUANT-UTRA
Engineering rules This is the measurement quantity information. The Threshold
below is configured based on the measQuantityUtraFdd setting.
- cpich_EcN0: b1Threshold2UtraEcNO,b2Threshold2UtraEcNO
- cpich_RSCP: b1Threshold2UtraRSCP, b2Threshold2UtraRSCP
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-339


CHAPTER 2. Parameter Description

MEAS_QUANTITY_UTRA_TDD
Parameter name MEAS_QUANTITY_UTRA_TDD
Description Measurement quantity information for UTRA TDD measurement.
It is set to only pccpch_RSCP.
Object class & hierarchy PLDQuantityConfigUtra
Type Static
Data Type word16
Unit NA
Range ci_pccpch_RSCP
Read/Write READ/WRITE
Default value ci_pccpch_RSCP
Rec. Value ci_pccpch_RSCP
Commands RTRV-QUANT-UTRA/CHG-QUANT-UTRA
Engineering rules This is the measurement quantity information. The Threshold
below is configured based on the measQuantityUtraFdd setting.
- cpich_EcN0: b1Threshold2UtraEcNO,b2Threshold2UtraEcNO
- cpich_RSCP: b1Threshold2UtraRSCP, b2Threshold2UtraRSCP
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-340 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MEASUREMENT_BANDWIDTH
Parameter name MEASUREMENT_BANDWIDTH
Description Max. allowed measurement bandwidth for carrier frequency.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range ci_mbw6/ci_mbw15/ci_mbw25/ci_mbw50/ci_mbw75/ci_mbw100
Read/Write READ/WRITE
Default value ci_mbw50
Rec. Value ci_mbw50
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The measurementBandwidth is used to indicate the maximum
allowed measurement bandwidth on a carrier frequency as defined
by the parameter Transmission Bandwidth Configuration ‘NRB’
3GPP TS 36.104. The values mbw6, mbw15, mbw25, mbw50,
mbw75, mbw100 indicate 6, 15, 25, 50, 75 and 100 resource
blocks respectively.
ci_mbw6 = 0,
ci_mbw15 = 1,
ci_mbw25 = 2,
ci_mbw50 = 3,
ci_mbw75 = 4,
ci_mbw100 = 5
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-341


CHAPTER 2. Parameter Description

MEASUREMENT_INTERVAL
Parameter name MEASUREMENT_INTERVAL
Description A value used when the Measured Periodicity in E-CID
measurement initiation request is periodic. At this time, an eNB
receives MR periodically from the UE. An operator can set up the
interval, that is a different value from the interval used in the eNB.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word32
Unit NA
Range ci_120ms/ci_240ms/ci_480ms/ci_640ms/ci_1024ms/ci_2048ms/
ci_5120ms/ci_10240ms/ci_1min/ci_6min/ci_12min/ci_30min/ci_60
min
Read/Write READ/WRITE
Default value ci_120ms
Rec. Value ci_120ms
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The 13 ranges from 0~12 are mapped as detailed below:
120 ms, 240 ms, 480 ms, 640 ms, 1024 ms, 2048 ms, 5120 ms,
10240 ms, 1 min, 6 min, 12 min, 30 min, 60 min
The closer the setting is to 120 ms,
- a device sends MR in shorter interval;
- allows more accurate positioning service with the latest data; and
- there is potential of degraded performance due to increased
number of MR that eNB needs to process.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-342 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MESA_BANDWIDTH_USAGE
Parameter name MEAS_BANDWIDTH_USAGE
Description Whether to use measurementBandwidth.
- CI_no_use: measurementBandwidth is not used.
- CI_use: measurementBandwidth is used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type enum
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This information determines whether or not the
measurementBandwidth is used by the system.
In case of this parameter value is CI_no_use, the allowedMesMeas
Bandwidth is not included in the SystemInformationBlockType3.
But the value corresponding to the downlink bandwidth indicated
by the dl-Bandwidth included in MasterInformationBlock applies to
the UE.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-343


CHAPTER 2. Parameter Description

MME_FAILOVER_TIMER
Parameter name MME_FAILOVER_TIMER
Description If SCTP connection is successfully recovered within
mmeFailoverTimer since MME SCTP connection is lost, a call
connected to the MME is maintained by this timer. Its unit is sec.
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit sec
Range 1-30
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-SCTP-PARA/CHG-SCTP-PARA
Engineering rules When the S1 SCTP Link connected between the MME and the
eNB is disconnected, the Link within the mmeFailoverTimer is
reset. This reset is to prevent Call Drop in S1 Link connection, and
the timer is what maintains the S1 Link status to prevent Call Drop.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-344 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MME_INDEX
Parameter name MME_INDEX
Description Index to access information. Because total 16 MMEs can be
connected to an eNB, the index has 0-15.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type word32
Unit NA
Range 0-15
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-MME-CONF
Engineering rules The total number of MMEs that can be connected to a Base Station
is 16. Accordingly, the index has the value from 0 to 15.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-345


CHAPTER 2. Parameter Description

MME_IPV4
Parameter name MME_IPV4
Description IPV4 address information of MME. This value is valid only when
the IP_VER is IPv4. This is not used if the IP_VER is IPv6.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type IPv4Address
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value ‘0.0.0.0’
Rec. Value ‘0.0.0.0’
Commands RTRV-MME-CONF/CHG-MME-CONF
Engineering rules Enters the IPV4 Address of the MME for connection. If the IP value
is entered and the status is EQUIP, then the corresponding Base
Station engages the S1 Setup process with the corresponding
MME.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-346 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MME_IPV6
Parameter name MME_IPV6
Description IPV6 address information of a base station. This value is valid only
when the IP_VER is IPv6. This is not used if the IP_VER is IPv4.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type IPv6Address
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value ‘0:0:0:0:0:0:0:0’
Rec. Value ‘0:0:0:0:0:0:0:0’
Commands RTRV-MME-CONF/CHG-MME-CONF
Engineering rules Enters the IPV6 Address of the MME for connection. If the IP value
is entered and the status is EQUIP, then the corresponding Base
Station engages the S1 Setup process with the corresponding
MME.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-347


CHAPTER 2. Parameter Description

MME_SELECT_FACTOR_FOR_RIM
Parameter name MME_SELECT_FACTOR_FOR_RIM
Description Weight to select MME to perform RIM procedure.
Object class & hierarchy PLDHandoverOptionInfoFunc
Type Static
Data Type int
Unit NA
Range 0-15
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-HO-OPT/CHG-HO-OPT
Engineering rules This is used when selecting the MME for RIM.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

MNC
Parameter name MNC
Description The PLMN information (MNC) of a GERAN neighbor cell located
around a base station, Enter 3-digit or 2-digit number whose each
digit range is 0-9.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the MNC of the GERAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-348 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC0
Parameter name MNC0
Description MNC comprising PLMN. FA has the Preference0 for PLMN #0.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the first Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-349


CHAPTER 2. Parameter Description

MNC0
Parameter name MNC0
Description MNC comprising PLMN.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB (System Information
Block) 1 when a cell is operating, Total 6 PLMN lists are
transmitted. Enter the MNC value of PLMN #0 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-350 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC0
Parameter name MNC0
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-
EUTRAN/DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC of the EUTRAN neighboring
Cell. This information is used during Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-351


CHAPTER 2. Parameter Description

MNC0
Parameter name MNC0
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘DIGIT_MNC’
Rec. Value ‘DIGIT_MNC’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MNC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-352 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC1
Parameter name MNC1
Description MNC comprising PLMN. FA has the Preference1 for PLMN #1.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the second Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-353


CHAPTER 2. Parameter Description

MNC1
Parameter name MNC1
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating,
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #1 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-354 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC1
Parameter name MNC1
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC of the EUTRAN neighboring
Cell. This information is used during Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-355


CHAPTER 2. Parameter Description

MNC1
Parameter name MNC1
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MNC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-356 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC2
Parameter name MNC2
Description MNC comprising PLMN. FA has the Preference2 for PLMN #2.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the third Mobile Country Code
(MCC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-357


CHAPTER 2. Parameter Description

MNC2
Parameter name MNC2
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating,
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #2 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-358 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC2
Parameter name MNC2
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC of the EUTRAN neighboring
Cell. This information is used during Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-359


CHAPTER 2. Parameter Description

MNC2
Parameter name MNC2
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MNC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-360 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC3
Parameter name MNC3
Description MNC comprising PLMN. FA has the Preference3 for PLMN #3.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the fourth Mobile Network Code
(MNC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

MNC3
Parameter name MNC3
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating,
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #3 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-361


CHAPTER 2. Parameter Description

MNC3
Parameter name MNC3
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-
EUTRAN/DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC of the EUTRAN neighboring
Cell. This information is used during Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

2-362 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC3
Parameter name MNC3
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MNC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-363


CHAPTER 2. Parameter Description

MNC4
Parameter name MNC4
Description MNC comprising PLMN. FA has the Preference4 for PLMN #4.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the fifth Mobile Network Code
(MNC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

MNC4
Parameter name MNC4
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating.
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #4 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-364 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC4
Parameter name MNC4
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC of the EUTRAN neighboring
Cell. This information is used during Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-365


CHAPTER 2. Parameter Description

MNC4
Parameter name MNC4
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MNC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-366 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC5
Parameter name MNC5
Description MNC comprising PLMN. FA has the Preference5 for PLMN #5.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting the 6th Mobile Network Code
(MNC) supported by the corresponding Cell.
Valid entry can be from 000 to 999, and the FFF entry signifies that
this feature is not used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-367


CHAPTER 2. Parameter Description

MNC5
Parameter name MNC5
Description MCC comprising PLMN.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules This is broadcasted to a UE through SIB 1 when a cell is operating.
Total 6 PLMN lists are transmitted.
Enter the MCC value of PLMN #5 that is out of the six.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-368 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

MNC5
Parameter name MNC5
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type char
Unit DIGIT
Range -128-127
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the MNC of the EUTRAN neighboring
Cell. This information is used during Handover.
Caution/Note Accurately set the required information to be used during
Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-369


CHAPTER 2. Parameter Description

MNC5
Parameter name MNC5
Description The PLMN list information (MNC) of a E-UTRAN neighbor cell
located around a base station, Enter 3-digit or 2-digit number
whose each digit range is 0-9.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type char
Unit DIGIT
Range 3 DIGITS, 0-9
Read/Write READ/WRITE
Default value ‘FFF’
Rec. Value ‘FFF’
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the MNC of the UTRAN neighboring Cell.
This information is used during RIM operation and Handover.
Caution/Note Accurately set the required information to be used during RIM
operation and Handover.
Delta NA
Real time change Yes
Need to reset No

2-370 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

M_ORG_DATA_AC_UECOUNT
Parameter name M_ORG_DATA_AC_UECOUNT
Description Number of mobile originating data access UEs.
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This is the originating data access ue count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

M_ORG_DATA_AC_UECOUNT
Parameter name M_ORG_DATA_AC_UECOUNT
Description Number of mobile originating data access UEs
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules This is the originating data access ue count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-371


CHAPTER 2. Parameter Description

M_ORG_DATA_AC_UECOUNT
Parameter name M_ORG_DATA_AC_UECOUNT
Description Number of mobile originating data access UEs
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules This is the originating data access ue count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

M_ORG_DATA_AC_UECOUNT
Parameter name M_ORG_DATA_AC_UECOUNT
Description Number of mobile originating data access UEs
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules This is the originating data access ue count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-372 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

M_ORG_SIGNAL_AC_UECOUNT
Parameter name M_ORG_SIGNAL_AC_UECOUNT
Description Number of mobile originating signalling access UEs.
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This is the originating signaling UE count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

M_ORG_SIGNAL_AC_UECOUNT
Parameter name M_ORG_SIGNAL_AC_UECOUNT
Description Number of mobile originating signalling access UEs
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules This is the originating signaling UE count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-373


CHAPTER 2. Parameter Description

M_ORG_SIGNAL_AC_UECOUNT
Parameter name M_ORG_SIGNAL_AC_UECOUNT
Description Number of mobile originating signalling access UEs
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules This is the originating signaling UE count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

M_ORG_SIGNAL_AC_UECOUNT
Parameter name M_ORG_SIGNAL_AC_UECOUNT
Description Number of mobile originating signalling access UEs
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules This is the originating signaling UE count of the
establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-374 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

M_TERM_AC_UECOUNT
Parameter name M_TERM_AC_UECOUNT
Description Number of mobile terminating access UEs
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules This is the mobile terminated call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

M_TERM_AC_UECOUNT
Parameter name M_TERM_AC_UECOUNT
Description Number of mobile terminating access UEs
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules This is the mobile terminated call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-375


CHAPTER 2. Parameter Description

M_TERM_AC_UECOUNT
Parameter name M_TERM_AC_UECOUNT
Description Number of mobile terminating access UEs
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules This is the mobile terminated call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

M_TERM_AC_UECOUNT
Parameter name M_TERM_AC_UECOUNT
Description Number of mobile terminating access UEs
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules This is the mobile terminated call count of the establishmentCause.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-376 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.14 N
N310
Parameter name N310
Description Indicates the maximum count of the out-of-sync Indications which
the UE receives from the lower-layer. The initial value is 10, and it
can be changed by the operator during operation as follows:
- ci_n_310_n1: indicates 1.
- ci_n_310_n2: indicates 2.
- ci_n_310_n3: indicates 3.
- ci_n_310_n4: indicates 4.
- ci_n_310_n6: indicates 6.
- ci_n_310_n8: indicates 8.
- ci_n_310_n10: indicates 10.
- ci_n_310_n20: indicates 20.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_n_310_n1/ci_n_310_n2/ci_n_310_n3/ci_n_310_n4/ci_n_310_n6/
ci_n_310_n8/ci_n_310_n10/ci_n_310_n20
Read/Write READ/WRITE
Default value ci_n_310_n10
Rec. Value ci_n_310_n10
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-377


CHAPTER 2. Parameter Description

N311
Parameter name N311
Description Indicates the maximum count of the In-sync Indications which the UE
receives from the lower-layer. The initial value is 1, and it can be
changed by the operator during operation as follows:
- ci_n_311_n1: indicates 1.
- ci_n_311_n2: indicates 2.
- ci_n_311_n3: indicates 3.
- ci_n_311_n4: indicates 4.
- ci_n_311_n5: indicates 5.
- ci_n_311_n6: indicates 6.
- ci_n_311_n8: indicates 8.
- ci_n_311_n10: indicates 10.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_n_311_n1/ci_n_311_n2/ci_n_311_n3/ci_n_311_n4/ci_n_311_n5/
ci_n_311_n6/ci_n_311_n8/ci_n_311_n10
Read/Write READ/WRITE
Default value ci_n_311_n1
Rec. Value ci_n_311_n1
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-378 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

N3_REQUEST
Parameter name N3_REQUEST
Description Maximum transmissions count of the GTP ECHO-REQ message;
enabled only when KEEP_ALIVE is ‘1’.
Object class & hierarchy PLDGtpInfoFunc
Type Static
Data Type byte
Unit NA
Range 0-10
Read/Write READ/WRITE
Default value 5
Rec. Value 5
Commands RTRV-GTP-INF/CHG-GTP-INF
Engineering rules The corresponding parameter is the GTP Echo Request
retransmission count, and the specification recommends the
parameter be set to 5 (5 retransmissions).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

NBR_ENB_INDEX
Parameter name NBR_ENB_INDEX
Description Index of the neighbor eNB. The value entered upon registering the
neighbor eNB is used.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the Index of the registered Neighbor eNB.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-379


CHAPTER 2. Parameter Description

NBR_ENB_IPV4
Parameter name NBR_ENB_IPV4
Description Enter the neighbor eNB IP information in the form of IP Version4.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type IPv4Address
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value ‘0.0.0.0’
Rec. Value ‘0.0.0.0’
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the IP version 4 Address of the Neighbor
eNB. This information is used during X2 Link Setup.
Caution/Note Accurately set the information to ensure proper X2 Setup.
Delta NA
Real time change Yes
Need to reset No

NBR_ENB_IPV6
Parameter name NBR_ENB_IPV6
Description Enter the neighbor eNB IP information in the form of IP Version6.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type IPv6Address
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value ‘0:0:0:0:0:0:0:0’
Rec. Value ‘0:0:0:0:0:0:0:0’
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the IP version 6 Address of the Neighbor
eNB. This information is used during X2 Link Setup.
Caution/Note Accurately set the information to ensure proper X2 Setup.
Delta NA
Real time change Yes
Need to reset No

2-380 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NCC_PERMITTED_BIT1
Parameter name NCC_PERMITTED_BIT1
Description The 1st bit of the nccPermitted of GERAN FA object.
- False: Value of 1st bit is 0
- True: Value of 1st bit is 1.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-381


CHAPTER 2. Parameter Description

NCC_PERMITTED_BIT2
Parameter name NCC_PERMITTED_BIT2
Description The 2nd bit of the nccPermitted of GERAN FA object.
- False: value of 2nd bit is 0
- True: value of 2nd bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-382 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NCC_PERMITTED_BIT3
Parameter name NCC_PERMITTED_BIT3
Description The 3rd bit of the nccPermitted of GERAN FA object.
- False: value of 3rd bit is 0
- True: value of 3rd bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-383


CHAPTER 2. Parameter Description

NCC_PERMITTED_BIT4
Parameter name NCC_PERMITTED_BIT4
Description The 4th bit of the nccPermitted of GERAN FA object.
- False: value of 4th bit is 0
- True: value of 4th bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-384 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NCC_PERMITTED_BIT5
Parameter name NCC_PERMITTED_BIT5
Description The 5th bit of the nccPermitted of GERAN FA object.
- False: value of 5th bit is 0
- True: value of 5th bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-385


CHAPTER 2. Parameter Description

NCC_PERMITTED_BIT6
Parameter name NCC_PERMITTED_BIT6
Description The 6th bit of the nccPermitted of GERAN FA object.
- False: value of 6th bit is 0
- True: value of 6th bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-386 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NCC_PERMITTED_BIT7
Parameter name NCC_PERMITTED_BIT7
Description The 7th bit of the nccPermitted of GERAN FA object.
- False: value of 7th bit is 0
- True: value of 7th bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-387


CHAPTER 2. Parameter Description

NCC_PERMITTED_BIT8
Parameter name NCC_PERMITTED_BIT8
Description The 8th bit of the nccPermitted of GERAN FA object.
- False: value of 8th bit is 0
- True: value of 8th bit is 1
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the bit value that configures the NCC-
Permitted bitmap. The NCC-Permitted is configured with 8 bits,
nccPermittedBit1-nccPermittedBit8. nccPermittedBit1 indicates the
MSB, while nccPermittedBit8 indicates the LSB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-388 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

N_CELL_CHANGE_HIGH
Parameter name N_CELL_CHANGE_HIGH
Description Indicates the value of the number of cell change in high mobility
state of the cell within an eNB.
Object class & hierarchy PLDMobilityStateInfoLogic
Type Static
Data Type short
Unit NA
Range 1-16
Read/Write READ/WRITE
Default value 10
Rec. Value 10
Commands RTRV-MOBIL-STA/CHG-MOBIL-STA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

N_CELL_CHANGE_MEDIUM
Parameter name N_CELL_CHANGE_MEDIUM
Description Indicates the value of the number of cell change in medium mobility
state of the cell within an eNB.
Object class & hierarchy PLDMobilityStateInfoLogic
Type Static
Data Type short
Unit NA
Range 1-16
Read/Write READ/WRITE
Default value 5
Rec. Value 5
Commands RTRV-MOBIL-STA/CHG-MOBIL-STA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-389


CHAPTER 2. Parameter Description

NEIGH_CELL_CONFIG
Parameter name NEIGH_CELL_CONFIG
Description Indicates the neighbor cell’s configuration information.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range 0-3
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The neighCellConfig is used to provide the information related to
MBSFN and TDD UL/DL configuration of neighbour cells.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-390 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NETWORK_COLOUR_CODE
Parameter name NETWORK_COLOUR_CODE
Description Indicates the network colour code of the GERAN neighbor cell
located near the eNB.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type byte
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the Network Colour Code of the GERAN
Neighbor Cell. Codes are from 0 to 7.
Caution/Note Be careful not to enter previously entered information. (If all three
of the networkColourCode, baseStationColourCode, and ARFCN
information match previously entered information, the system
determines it to be a repeated entry.)
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-391


CHAPTER 2. Parameter Description

NO_HO
Parameter name NO_HO
Description Indicates whether handover is done to the neighbor eNB.
- False: Handover is done to the neighbor eNB.
- True: Handover is not done to the neighbor eNB.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type short
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter determines whether or not HO is possible with the
Neighbor eNB. If the setting is FALSE, normal Handover is executed.
If it is TRUE, then Handover is not performed.
Caution/Note The parameter must be set accurately for Handover to be executed
as determined by the setting.
Delta NA
Real time change Yes
Need to reset No

2-392 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NORMAL_PRIORITY0
Parameter name NORMAL_PRIORITY0
Description Indicates the first priority in the normal type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value ccoWithNacc
Rec. Value ccoWithNacc
Commands RTRV-GERAN-INTWO/CHG-GERAN-INTWO
Engineering rules This is the parameter that indicates the priority order for the MR
based GERAN interworking process, excluding PS-HO. The setting
is comprised of 4 stages, ranging from normalPriority0-
normalPriority3, with normalPriority0 being the highest priority.
Caution/Note PS-HO has the highest priority in GERAN interworking. If PS-HO is
not possible, then the interworking process is determined based on
the preset order of priority.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-393


CHAPTER 2. Parameter Description

NORMAL_PRIORITY1
Parameter name NORMAL_PRIORITY1
Description Indicates the second priority in the normal type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value enhancedRedirection
Rec. Value enhancedRedirection
Commands RTRV-GERAN-INTWO/CHG-GERAN-INTWO
Engineering rules This is the parameter that indicates the priority order for the MR
based GERAN interworking process, excluding PS-HO. The setting
is comprised of 4 stages, ranging from normalPriority0-
normalPriority3, with normalPriority0 being the highest priority.
Caution/Note PS-HO has the highest priority in GERAN interworking. If PS-HO is
not possible, then the interworking process is determined based on
the preset order of priority.
Delta NA
Real time change Yes
Need to reset No

2-394 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NORMAL_PRIORITY2
Parameter name NORMAL_PRIORITY2
Description Indicates the third priority in the normal type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value ccoWithOutNacc
Rec. Value ccoWithOutNacc
Commands RTRV-GERAN-INTWO/CHG-GERAN-INTWO
Engineering rules This is the parameter that indicates the priority order for the MR
based GERAN interworking process, excluding PS-HO. The setting
is comprised of 4 stages, ranging from normalPriority0-
normalPriority3, with normalPriority0 being the highest priority.
Caution/Note PS-HO has the highest priority in GERAN interworking. If PS-HO is
not possible, then the interworking process is determined based on
the preset order of priority.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-395


CHAPTER 2. Parameter Description

NORMAL_PRIORITY3
Parameter name NORMAL_PRIORITY3
Description Indicates the fourth priority in the normal type GERAN interworking
procedure.
- ccoWithNACC: CCO with NACC
- ccoWithoutNACC: CCO without NACC
- enhancedRedirection: Enhanced Redirection with SI
- geranRedirecdtion: Redirection without SI
Object class & hierarchy PLDGeranInterworking
Type Static
Data Type word16
Unit NA
Range ccoWithNacc/ccoWithOutNacc/enhancedRedirection/
geranRedirection
Read/Write READ/WRITE
Default value geranRedirection
Rec. Value geranRedirection
Commands RTRV-GERAN-INTWO/CHG-GERAN-INTWO
Engineering rules This is the parameter that indicates the priority order for the MR
based GERAN interworking process, excluding PS-HO. The setting
is comprised of 4 stages, ranging from normalPriority0-
normalPriority3, with normalPriority0 being the highest priority.
Caution/Note PS-HO has the highest priority in GERAN interworking. If PS-HO is
not possible, then the interworking process is determined based on
the preset order of priority.
Delta NA
Real time change Yes
Need to reset No

2-396 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NO_X2
Parameter name NO_X2
Description Indicates whether the X2 connection with the neighbor eNB is set up.
- False: X2 connection with the neighbor eNB is set up.
- True: X2 connection with the neighbor eNB is not set up.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type short
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter determines whether or not to execute X2 Link Setup
with the Neighbor eNB. If the setting is False, X2 Link Setup is
executed. If it is True, then X2 Link Setup is not performed.
Caution/Note The parameter must be set accurately for X2 Link Setup to be
executed as determined by the setting.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-397


CHAPTER 2. Parameter Description

NUM_OF_DL_FRAME
Parameter name NUM_OF_DL_FRAME
Description Number of downlink frames. If an operator enters this value, the
eNB forwards the value to the MAC layer.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word32
Unit NA
Range ci_sf1(0)/ci_sf2(1)/ci_sf4(2)/ci_sf6(3)
Read/Write READ/WRITE
Default value ci_sf1(0)
Rec. Value ci_sf1(0)
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules Values from 0 to 3 are mapped with sf1, sf2, sf4, and sf6. It is the
value for transmitting to MAC Layer without being used in the
Signal Processing Block.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-398 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

NUM_OF_ENB
Parameter name NUM_OF_ENB
Description Number of the target eNBs where the multi-target preparation will
be done upon handover. Up to 4 eNBs can be entered for
preparation.
If ‘1’ is entered, the multi-target preparation is not performed.
Object class & hierarchy PLDHandoverOptionInfoFunc
Type Static
Data Type int
Unit NA
Range 1-4
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-HO-OPT/CHG-HO-OPT
Engineering rules This is used during the Multi Target Preparation.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-399


CHAPTER 2. Parameter Description

NUM_PATH_RE_TX
Parameter name NUM_PATH_RE_TX
Description The retransmission count by which the SCTP link will be
disconnected if the response to the heartbeat is not received for
more than numPathReTx, when the heartbeat message is sent to
check if the SCTP link is normal.
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit count
Range 1-100
Read/Write READ/WRITE
Default value 5
Rec. Value 5
Commands RTRV-SCTP-PARA/CHG-SCTP-PARA
Engineering rules HeartBeat message is transmitted to determine validity of the
SCTP Link Connection between two nodes. If the transmitting node
does not receive HeartBeat ACK message from the receiving node
in a count greater than the number specified in numPathReTx, then
the system determines the corresponding path is abnormal.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-400 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.15 O
OFFSET_FREQ
Parameter name OFFSET_FREQ
Description The frequency offset value which is applied to the offsetFreq in the
RRC Connection Reconfiguration message.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type enum
Unit dB
Range ci_dB-24/ci_dB-22/ci_dB-20/ci_dB-18/ci_dB-16/ci_dB-14/
ci_dB-12/ci_dB-10/ci_dB-8/ci_dB-6/ci_dB-5/ci_dB-4/ci_dB-3/
ci_dB-2/ci_dB-1/ci_dB0/ci_dB1/ci_dB2/ci_dB3/ci_dB4/ci_dB5/
ci_dB6/ci_dB8/ci_dB10/ci_dB12/ci_dB14/ci_dB16/ci_dB18/
ci_dB20/ci_dB22/ci_dB24
Read/Write READ/WRITE
Default value ci_dB0
Rec. Value ci_dB0
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used in the RRC Connection Reconfiguration
message.
The offsetFreq is used to indicate afrequency specific offset to be
applied when evaluating candidates for cell re-selection or when
evaluating triggering conditions for measurement reporting.
The value in dB. Value dB-24 corresponds to -24 dB, dB-22
corresponds to -22 dB and so on.
ci_dB_24 = 0, /* display_name: ‘ci_dB-24’ */
ci_dB_22 = 1, /* display_name: ‘ci_dB-22’ */
ci_dB_20 = 2, /* display_name: ‘ci_dB-20’ */
ci_dB_18 = 3, /* display_name: ‘ci_dB-18’ */
ci_dB_16 = 4, /* display_name: ‘ci_dB-16’ */
ci_dB_14 = 5, /* display_name: ‘ci_dB-14’ */
ci_dB_12 = 6, /* display_name: ‘ci_dB-12’ */
ci_dB_10 = 7, /* display_name: ‘ci_dB-10’ */
ci_dB_8 = 8, /* display_name: ‘ci_dB-8’ */
ci_dB_6 = 9, /* display_name: ‘ci_dB-6’ */
ci_dB_5 = 10, /* display_name: ‘ci_dB-5’ */
ci_dB_4 = 11, /* display_name: ‘ci_dB-4’ */
ci_dB_3 = 12, /* display_name: ‘ci_dB-3’ */
ci_dB_2 = 13, /* display_name: ‘ci_dB-2’ */
ci_dB_1 = 14, /* display_name: ‘ci_dB-1’ */
ci_dB0 = 15,
ci_dB1 = 16,
ci_dB2 = 17,

© SAMSUNG Electronics Co., Ltd. 2-401


CHAPTER 2. Parameter Description

(Continued)

Engineering rules ci_dB3 = 18,


ci_dB4 = 19,
ci_dB5 = 20,
ci_dB6 = 21,
ci_dB8 = 22,
ci_dB10 = 23,
ci_dB12 = 24,
ci_dB14 = 25,
ci_dB16 = 26,
ci_dB18 = 27,
ci_dB20 = 28,
ci_dB22 = 29,
ci_dB24 = 30
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-402 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

OFFSET_FREQ
Parameter name OFFSET_FREQ
Description The offset value for the carrier frequency of the GERAN FA object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -15 to 15
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This is the offset value on the Carrier Frequency of the GERAN FA
Object. It is in units of dB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

OFFSET_FREQ
Parameter name OFFSET_FREQ
Description The offset value applied to the UTRA carrier frequency.
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit dBm
Range -15 to 15
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This is the offset value on the Carrier Frequency of the UTRA FA
Object. It is in units of dB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-403


CHAPTER 2. Parameter Description

OPEN_PCIRANGE
Parameter name OPEN_PCIRANGE
Description The range of PCI value of an open cell. The range value includes
the start value.
Object class & hierarchy PLDOpenPciInfoLogic
Type Static
Data Type word32
Unit NA
Range ci_rangePCI_n4/ci_rangePCI_n8/ci_rangePCI_n12/
ci_rangePCI_n16/ci_rangePCI_n24/ci_rangePCI_n32/
ci_rangePCI_n48/ci_rangePCI_n64/ci_rangePCI_n84/
ci_rangePCI_n96/ci_rangePCI_n128/ci_rangePCI_n168/
ci_rangePCI_n252/ci_rangePCI_n504
Read/Write READ/WRITE
Default value ci_rangePCI_n4
Rec. Value ci_rangePCI_n4
Commands RTRV-OPENPCI-INF/CHG-OPENPCI-INF
Engineering rules This parameter specifies the Open PCI range with one of the
following settings:
ci_rangePCI_n4,
ci_rangePCI_n8,
ci_rangePCI_n12,
ci_rangePCI_n16,
ci_rangePCI_n24,
ci_rangePCI_n32,
ci_rangePCI_n48,
ci_rangePCI_n64,
ci_rangePCI_n84,
ci_rangePCI_n96,
ci_rangePCI_n128,
ci_rangePCI_n168,
ci_rangePCI_n252,
ci_rangePCI_n504
The numbers above signify the number of serial PCI that include
openPCIStart value. For example, if the openPCIStart value is 300,
and the openPCIRange is ci_rangePCI_n4, then the
300/301/302/303 is the Open PCI.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-404 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

OPEN_PCIRANGE_USAGE
Parameter name OPEN_PCIRANGE_USAGE
Description Indicates whether to use the PCI range of an open cell.
- CI_no_use: No Use.
- CI_use: Use.
Object class & hierarchy PLDOpenPciInfoLogic
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-OPENPCI-INF/CHG-OPENPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-405


CHAPTER 2. Parameter Description

OPEN_PCISTART
Parameter name OPEN_PCISTART
Description The PCI start value of an open cell.
Object class & hierarchy PLDOpenPciInfoLogic
Type Static
Data Type word32
Unit NA
Range 0-503
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-OPENPCI-INF/CHG-OPENPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

ORIENTATION_OF_MAJOR_AXIS
Parameter name ORIENTATION_OF_MAJOR_AXIS
Description The value of the Orientation Of Major Axis; for which an operator
directly enters a value between 0-179.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word16
Unit NA
Range 0-179
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The default value is recommended.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-406 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

OTDOA_ENABLE
Parameter name OTDOA_ENABLE
Description If the otdoaEnable value is set to 1 (On) to enable the OTDOA
included in the UE positioning function, the eNB sends the PRS
signal, and the UE sends the information including the relevant
configurations to the eNB. If the otdoaEnable value is set to 0 (Off),
the PRS is not sent, and the eNB sends the information where the
relevant cell information is empty.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules Whether or not to receive PRS information can be set to manage a
device’s battery consumption.
- Battery consumption is high if the option is set to 1.
- Battery consumption is low if the option is set to 0.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-407


CHAPTER 2. Parameter Description

OVER_BOOKING_RATIO
Parameter name OVER_BOOKING_RATIO
Description Indicates the overbooking ratio for the downlink and uplink
threshold when the CAC is performed for each backhaul-based
QoS class identifier (QCI).
Object class & hierarchy PLDQciBhBwInfo
Type Static
Data Type float
Unit NA
Range 1.0-10.0
Read/Write READ/WRITE
Default value 1.0
Rec. Value 1.0
Commands RTRV-BHBW-QCI/CHG-BHBW-QCI
Engineering rules This is the parameter used to determine the threshold for Downlink/
Uplink when executing Backhaul CAC. It indicates the ratio that
can exceed the threshold.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-408 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

OVER_BOOKING_RATIO
Parameter name OVER_BOOKING_RATIO
Description Indicates the overbooking ratio for the downlink and uplink
threshold when the CAC is performed for each backhaul-based
service group.
Object class & hierarchy PLDSvcGrpBhBwInfo
Type Static
Data Type float
Unit NA
Range 1.0-10.0
Read/Write READ/WRITE
Default value 1.0
Rec. Value 1.0
Commands RTRV-BHBW-SVCGR/CHG-BHBW-SVCGR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-409


CHAPTER 2. Parameter Description

OWNER_TYPE
Parameter name OWNER_TYPE
Description The field which indicates how a neighbor is allocated, e.g. Initial
NRT/ANR by Server/ANR by UE/Created by User Command/
CreatedByUserUI.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range 0-5
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the Neighbor eNB creator. The Initial NRT/
ANR by Server/ANR by UE/Created by User Command/
CreatedByUserUI is determined by the creator.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-410 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.16 P
PCI_RANGE
Parameter name PCI_RANGE
Description The range from the starting physical cell ID of a black list cell.
For the single physical cell ID type, it is not used.
Object class & PLDBlackListedCellInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rangePCI_n4/ci_rangePCI_n8/ci_rangePCI_n12/ci_rangePCI_n16/
ci_rangePCI_n24/ci_rangePCI_n32/ci_rangePCI_n48/ci_rangePCI_n64/
ci_rangePCI_n84/ci_rangePCI_n96/ci_rangePCI_n128/ci_rangePCI_n168/
ci_rangePCI_n252/ci_rangePCI_n504
Read/Write READ/WRITE
Default value ci_rangePCI_n4
Rec. Value ci_rangePCI_n4
Commands RTRV-BLACK-LIST/CHG-BLACK-LIST/CRTE-BLACK-LIST/
DLT-BLACK-LIST
Engineering rules This parameter specifies the blacklist Cell range with one of the following
settings:
ci_rangePCI_n4,
ci_rangePCI_n8,
ci_rangePCI_n12,
ci_rangePCI_n16,
ci_rangePCI_n24,
ci_rangePCI_n32,
ci_rangePCI_n48,
ci_rangePCI_n64,
ci_rangePCI_n84,
ci_rangePCI_n96,
ci_rangePCI_n128,
ci_rangePCI_n168,
ci_rangePCI_n252,
ci_rangePCI_n504
The numbers above signify the number of serial PCI that include startPci
value. For example, if the startPci value is 300, and the pciRange range is
ci_rangePCI_n4, then the 300/301/302/303 is the blacklist Cell range.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-411


CHAPTER 2. Parameter Description

PCI_TYPE
Parameter name PCI_TYPE
Description The physical cell ID type of a black list cell.
- ci_singlePci: Single PCI.
- ci_rangedPci: PCI range.
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word32
Unit NA
Range ci_singlePci/ci_rangedPci
Read/Write READ/WRITE
Default value ci_singlePci
Rec. Value ci_singlePci
Commands RTRV-BLACK-LIST/CHG-BLACK-LIST/CRTE-BLACK-LIST/
DLT-BLACK-LIST
Engineering rules This parameter deterimes the blacklist Cell type. If the pciType is
ci_singlePci, then the blacklist Cell has only one value, and the
pciRange is ignored. If the pciType is ci_rangedPci, then the
blacklist Cell range coincides with the setting.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-412 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PCI_TYPE
Parameter name PCI_TYPE
Description The PCI type of a CSG cell. It indicates whether to use a range of
CSG PCIs or a single PCI.
- ci_singlePci: One CSG PCI is used.
- ci_rangedPci: A range of CSG PCIs is used.
Object class & hierarchy PLDCsgPciInfoIdle
Type Static
Data Type word32
Unit NA
Range ci_singlePci/ci_rangedPci
Read/Write READ/WRITE
Default value ci_rangedPci
Rec. Value ci_rangedPci
Commands RTRV-CSGPCI-IDLE/CHG-CSGPCI-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-413


CHAPTER 2. Parameter Description

PCI_TYPE
Parameter name PCI_TYPE
Description The PCI type of a hybrid cell.
- ci_singlePci: Single PCI.
- ci_rangedPci: PCI range.
Object class & hierarchy PLDHybridPciInfoLogic
Type Static
Data Type word32
Unit NA
Range ci_singlePci/ci_rangedPci
Read/Write READ/WRITE
Default value ci_singlePci
Rec. Value ci_singlePci
Commands RTRV-HYBRIDPCI-INF/CHG-HYBRIDPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PCI_TYPE
Parameter name PCI_TYPE
Description The PCI type of an open cell.
- ci_singlePci: Single PCI.
- ci_rangedPci: PCI range.
Object class & hierarchy PLDOpenPciInfoLogic
Type Static
Data Type word32
Unit NA
Range ci_singlePci/ci_rangedPci
Read/Write READ/WRITE
Default value ci_singlePci
Rec. Value ci_singlePci
Commands RTRV-OPENPCI-INF/CHG-OPENPCI-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-414 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PDB
Parameter name PDB
Description The packet delay budget (PDB) of the QoS class identifier (QCI).
- ci_pdb50 msec: QCI’ PDB is 50 msec.
- ci_pdb100 msec: QCI’ PDB is 100 msec.
- ci_pdb150 msec: QCI’ PDB is 150 msec.
- ci_pdb200 msec: QCI’ PDB is 200 msec.
- ci_pdb250 msec: QCI’ PDB is 250 msec.
- ci_pdb300 msec: QCI’ PDB is 300 msec.
- ci_pdb350 msec: QCI’ PDB is 350 msec.
- ci_pdb400 msec: QCI’ PDB is 400 msec.
- ci_pdb450 msec: QCI’ PDB is 450 msec.
- ci_pdb500 msec: QCI’ PDB is 500 msec.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range ci_pdb50msec/ci_pdb100msec/ci_pdb1500msec/ci_pdb200msec/
ci_pdb250msec/ci_pdb3000msec/ci_pdb350msec/ci_pdb400msec/
ci_pdb450msec/ci_pdb500msec
Read/Write READ/WRITE
Default value ci_pdb300msec
Rec. Value ci_pdb300msec
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-415


CHAPTER 2. Parameter Description

PHY_CELL_ID
Parameter name PHY_CELL_ID
Description The physical cell ID.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range 0-503
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules It is used to allow the UE to identify the cell in a radio section, and
to recover the cell specific reference signal.
It should be allocated to avoid conflict between neighbor cells.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-416 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PHY_CELL_ID
Parameter name PHY_CELL_ID
Description Indicates the physical cell ID of the E-UTRAN neighbor cell located
near the eNB.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-503
Read/Write READ/WRITE
Default value 1
Rec. Value 1
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Physical Cell Id of the Neighbor
EUTRAN Cell. This information is exchanged between eNBs via X2
messages, and is used during Handover.
Caution/Note The setting must be accurate because the information is used
during Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-417


CHAPTER 2. Parameter Description

PELR
Parameter name PELR
Description The Packet Error Loss Rate (PLER) of the QoS class identifier
(QCI).
- ci_pler10_2: QCI’s PLER is 10 to the power of -2.
- ci_pler10_3: QCI’s PLER is 10 to the power of -3.
- ci_pler10_4: QCI’s PLER is 10 to the power of -4.
- ci_pler10_5: QCI’s PLER is 10 to the power of -5.
- ci_pler10_6: QCI’s PLER is 10 to the power of -6.
- ci_pler10_7: QCI’s PLER is 10 to the power of -7.
- ci_pler10_8: QCI’s PLER is 10 to the power of -8.
- ci_pler10_9: QCI’s PLER is 10 to the power of -9.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range ci_pler10_2/ci_pler10_3/ci_pler10_4/ci_pler10_5/ci_pler10_6/
ci_pler10_7/ci_pler10_8/ci_pler10_9
Read/Write READ/WRITE
Default value ci_pler10_6
Rec. Value ci_pler10_6
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-418 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PLMN0_PORTION
Parameter name PLMN0_PORTION
Description The PLMN0 portion of the network resource of the cell in the eNB.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR/CHG-NET-SHR
Engineering rules This is the parameter that indicates the share portion of the PLMN
index 0.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PLMN1_PORTION
Parameter name PLMN1_PORTION
Description The PLMN1 portion of the network resource of the cell in the eNB.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR/CHG-NET-SHR
Engineering rules This is the parameter that indicates the share portion of the PLMN
index 1.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-419


CHAPTER 2. Parameter Description

PLMN2_PORTION
Parameter name PLMN2_PORTION
Description The PLMN2 portion of the network resource of the cell in the eNB.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR/CHG-NET-SHR
Engineering rules This is the parameter that indicates the share portion of the PLMN
index 2.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PLMN3_PORTION
Parameter name PLMN3_PORTION
Description The PLMN3 portion of the network resource of the cell in the eNB.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR/CHG-NET-SHR
Engineering rules This is the parameter that indicates the share portion of the PLMN
index 3.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-420 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PLMN4_PORTION
Parameter name PLMN4_PORTION
Description The PLMN4 portion of the network resource of the cell in the eNB.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR/CHG-NET-SHR
Engineering rules This is the parameter that indicates the share portion of the PLMN
index 4.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PLMN5_PORTION
Parameter name PLMN5_PORTION
Description The PLMN5 portion of the network resource of the cell in the eNB.
Object class & hierarchy PLDNetworkShareInfo
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NET-SHR/CHG-NET-SHR
Engineering rules This is the parameter that indicates the share portion of the PLMN
index 5.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-421


CHAPTER 2. Parameter Description

PLMN_IDX
Parameter name PLMN_IDX
Description The PLMN index; its range is 0-5.
Object class & hierarchy PLDCallPlmnState
Type Static
Data Type word16
Unit NA
Range 0-5
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CALLPLMN-STS
Engineering rules READ/WRITE
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

PLMN_IDX
Parameter name PLMN_IDX
Description The PLMN index; its range is 0-5.
Object class & hierarchy PLDCellPlmnState
Type Static
Data Type word16
Unit NA
Range 0-5
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELLPLMN-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-422 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

P_MAX
Parameter name P_MAX
Description Used to restrict the uplink transmission power of the UE, and
calculate the compensation (see the 3GPP TS 36.304, 5.2.3.2)
parameter.
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type int
Unit NA
Range -30 to 33
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

P_MAX
Parameter name P_MAX
Description Maximum Tx power level in the UE
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dBm
Range -30 to 33
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The pMax to be used in the target cell. If absent the UE applies the
maximum power according to the UE capability.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-423


CHAPTER 2. Parameter Description

P_MAX_GERAN
Parameter name P_MAX_GERAN
Description The maximum RF power of the UE in the GERAN FA object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit dBm
Range 0-39
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This is the parameter that indicates the maximum RF output of the
UE for the GERAN Uplink Carrier Frequency, and it is in units of
dBm.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-424 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

P_MAX_USAGE
Parameter name P_MAX_USAGE
Description Indicates whether to use the maximum power available upon uplink
transmission by the UE from a cell.
- CI_no_use: UE uses the maximum power depending on the
capability.
- CI_use: UE uses the maximum power specified in pMax.
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-425


CHAPTER 2. Parameter Description

P_MAX_USAGE
Parameter name P_MAX_USAGE
Description Indicates whether to use pMax.
- CI_no_use: Does not use the pMax value.
- CI_use: Uses the pMax value.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type enum
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used to set whether or not the pMax is used by
the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

P_MAX_UTRA
Parameter name P_MAX_UTRA
Description Maximum RF output power of the UE.
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type int
Unit NA
Range -50 to 33
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-426 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

P_MAX_UTRA
Parameter name P_MAX_UTRA
Description Maximum RF output power of the UE.
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit dBm
Range -50 to 33
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This is the parameter that indicates the maximum RF output of the
UE for the UTRA Uplink Carrier Frequency, and it is in units of
dBm.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PRB_REPORT_PERIOD
Parameter name PRB_REPORT_PERIOD
Description The period of reporting the physical resource block (PRB) for QoS
CAC of each cell.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit sec
Range 1-5
Read/Write READ/WRITE
Default value 2
Rec. Value 2
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the parameter that indicates the PRB report receiving
interval for each Cell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-427


CHAPTER 2. Parameter Description

PREEMPTION_FLAG
Parameter name PREEMPTION_FLAG
Description Indicates whether to perform the preemption function for each cell.
- CI_not_use: Preemption function for each cell is not performed.
- CI_use: Preemption function for each cell is performed.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the parameter that determines whether the preemption
feature is used or not within a Cell. If this parameter is set to
CI_not_use, then preemption is not executed. If it is set to CI_use,
then preemption is executed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-428 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PREFERENCE0
Parameter name PREFERENCE0
Description Preference of the PLMN #0 for the FA.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range not_allowed_prefer/allowed_prefer/preferred_prefer
Read/Write READ/WRITE
Default value preferred_prefer
Rec. Value preferred_prefer
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules Specify the PLMN #0 preference for the corresponding E-UTRA
Frequency. It must be set as one of the following:
- not_allowed_prefer: PLMN is not allowed
- allowed_prefer: Priority of the carrier is lower than that of other
carriers in the same RAT
- preferred_prefer: Priority of the carrier is higher than that of other
carriers in the same RAT
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-429


CHAPTER 2. Parameter Description

PREFERENCE1
Parameter name PREFERENCE1
Description Preference of the PLMN #1 for the FA.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range not_allowed_prefer/allowed_prefer/preferred_prefer
Read/Write READ/WRITE
Default value not_allowed_prefer
Rec. Value not_allowed_prefer
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules Specify the PLMN #1 preference for the corresponding E-UTRA
Frequency. It must be set as one of the following:
- not_allowed_prefer: PLMN is not allowed
- allowed_prefer: Priority of the carrier is lower than that of other
carriers in the same RAT
- preferred_prefer: Priority of the carrier is higher than that of other
carriers in the same RAT
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-430 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PREFERENCE2
Parameter name PREFERENCE2
Description Preference of the PLMN #2 for the FA.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range not_allowed_prefer/allowed_prefer/preferred_prefer
Read/Write READ/WRITE
Default value not_allowed_prefer
Rec. Value not_allowed_prefer
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules Specify the PLMN #2 preference for the corresponding E-UTRA
Frequency. It must be set as one of the following:
- not_allowed_prefer: PLMN is not allowed
- allowed_prefer: Priority of the carrier is lower than that of other
carriers in the same RAT
- preferred_prefer: Priority of the carrier is higher than that of other
carriers in the same RAT
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-431


CHAPTER 2. Parameter Description

PREFERENCE3
Parameter name PREFERENCE3
Description Preference of the PLMN #3 for the FA.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range not_allowed_prefer/allowed_prefer/preferred_prefer
Read/Write READ/WRITE
Default value not_allowed_prefer
Rec. Value not_allowed_prefer
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules Specify the PLMN #3 preference for the corresponding E-UTRA
Frequency. It must be set as one of the following:
- not_allowed_prefer: PLMN is not allowed
- allowed_prefer: Priority of the carrier is lower than that of other
carriers in the same RAT
- preferred_prefer: Priority of the carrier is higher than that of other
carriers in the same RAT
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-432 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PREFERENCE4
Parameter name PREFERENCE4
Description Preference of the PLMN #4 for the FA.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range not_allowed_prefer/allowed_prefer/preferred_prefer
Read/Write READ/WRITE
Default value not_allowed_prefer
Rec. Value not_allowed_prefer
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules Specify the PLMN #4 preference for the corresponding E-UTRA
Frequency. It must be set as one of the following:
- not_allowed_prefer: PLMN is not allowed
- allowed_prefer: Priority of the carrier is lower than that of other
carriers in the same RAT
- preferred_prefer: Priority of the carrier is higher than that of other
carriers in the same RAT
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-433


CHAPTER 2. Parameter Description

PREFERENCE5
Parameter name PREFERENCE5
Description Preference of the PLMN #5 for the FA.
not_allowed_prefer
allowed_prefer
preferred_prefer
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range not_allowed_prefer/allowed_prefer/preferred_prefer
Read/Write READ/WRITE
Default value not_allowed_prefer
Rec. Value not_allowed_prefer
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules Specify the PLMN #5 preference for the corresponding E-UTRA
Frequency. It must be set as one of the following:
- not_allowed_prefer: PLMN is not allowed
- allowed_prefer: Priority of the carrier is lower than that of other
carriers in the same RAT
- preferred_prefer: Priority of the carrier is higher than that of other
carriers in the same RAT
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-434 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PRESENCE_ANT_PORT1
Parameter name PRESENCE_ANT_PORT1
Description Indicates whether the Antenna Port1 exists.
- False: Antenna Port1 does not exist.
- True: Antenna Port1 exists.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type BOOL
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The presenceAntPort1 is used to indicate whether all the
neighbouring cells use Antenna Port 1. When set to TRUE, the UE
may assume that at least two cell-specific antenna ports are used
in all neighbouring cells.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-435


CHAPTER 2. Parameter Description

PRIORITY
Parameter name PRIORITY
Description Priority information for the EUTRA FA.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 7
Rec. Value 7
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The priority concerns the absolute priority of the concerned E-
UTRA carrier frequency, as used by the cell reselection procedure.
Corresponds with parameter ‘priority’ in 3GPP TS 36.304. Value 0
means: lowest priority.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PRIORITY
Parameter name PRIORITY
Description Priority of the GERAN FA object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the Cell Reselection Priority for the
corresponding GERAN FA.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-436 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PRIORITY
Parameter name PRIORITY
Description Priority of cell reselection
Object class & hierarchy PLDIdleModeLbInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-IDLELB-INFO/CHG-IDLELB-INFO
Engineering rules This parameter indicates the Cell reselection Priority used during
Idle Mode Load Distribution. The information is transmitted to a
device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PRIORITY
Parameter name PRIORITY
Description Priority of the QoS class identifier (QCI); range is 1-16; ‘1’ means
the highest priority.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range 1-16
Read/Write READ/WRITE
Default value 9
Rec. Value 9
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-437


CHAPTER 2. Parameter Description

PRIORITY
Parameter name PRIORITY
Description Priority information for the UTRA FA.
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type int
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PRIORITY
Parameter name PRIORITY
Description Priority information for the UTRA FA.
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range 0-7
Read/Write READ/WRITE
Default value 4
Rec. Value 4
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter indicates the Cell Reselection Priority for the
corresponding UTRA FA.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-438 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PROFILE0001
Parameter name PROFILE0001
Description Indicates whether the profile0001 (RTP/UDP/IP) is supported.
- False: profile0001 is not supported.
- True: profile0001 is supported (default).
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PROFILE0002
Parameter name PROFILE0002
Description Indicates whether the profile0002 (UDP/IP) is supported.
- False: profile0002 is not supported.
- True: profile0002 is supported (default).
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-439


CHAPTER 2. Parameter Description

PROFILE0003
Parameter name PROFILE0003
Description Indicates whether the profile0003 (ESP/IP) is supported.
- False: profile0003 is not supported (default).
- True: profile0003 is supported.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PROFILE0004
Parameter name PROFILE0004
Description Indicates whether the profile0004 (IP) is supported.
- False: profile0004 is not supported.
- True: profile0004 is supported (default).
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-440 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PROFILE0006
Parameter name PROFILE0006
Description Indicates whether the profile0006 (TCP/IP) is supported.
- False: profile0006 is not supported (default).
- True: profile0006 is supported.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PROFILE0101
Parameter name PROFILE0101
Description Indicates whether the profile0101 (RTP/UDP/IP) is supported.
- False: profile0101 is not supported (default).
- True: profile0101 is supported.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-441


CHAPTER 2. Parameter Description

PROFILE0102
Parameter name PROFILE0102
Description Indicates whether the profile0102 (UDP/IP) is supported.
- False: profile0102 is not supported (default).
- True: profile0102 is supported.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PROFILE0103
Parameter name PROFILE0103
Description Indicates whether the profile0103 (ESP/IP) is supported.
- False: profile0103 is not supported (default).
- True: profile0103 is supported.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules NA
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-442 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PROFILE0104
Parameter name PROFILE0104
Description Indicates whether the profile0104 (IP) is supported.
- False: profile0104 is not supported (default).
- True: profile0104 is supported.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PRS_BANDWIDTH
Parameter name PRS_BANDWIDTH
Description The PRS bandwidth value. If an operator enters this value, the eNB
forwards the value to the MAC layer.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word16
Unit NA
Range 0-5
Read/Write READ/WRITE
Default value 3
Rec. Value 3
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules Transmission bandwidth of PRS.
Values from 0 to 5 are mapped with prsBw6, prsBw15, prsBw25,
prsBw50, prsBw75, and prsBw100.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-443


CHAPTER 2. Parameter Description

PRS_CONFIG_INDEX
Parameter name PRS_CONFIG_INDEX
Description The configuration index value. If an operator enters this value, the
eNB forwards the value to the MAC layer.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word32
Unit NA
Range 0-4095
Read/Write READ/WRITE
Default value 1131
Rec. Value 1131
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The default value is recommended.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

PRS_MUTING_CONFIG_SIZE
Parameter name PRS_MUTING_CONFIG_SIZE
Description The PRS muting configuration size value. If an operator enters this
value, the eNB forwards the value to the MAC layer.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word32
Unit NA
Range 0-3
Read/Write READ/WRITE
Default value 2
Rec. Value 2
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules If a bit is set to ‘0’, it indicates that the PRS is muted in the
corresponding PRS positioning occasion (numbering from any sub
frame for which SFN=0) in a periodic cycle of length equal to the
length of the bit string
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-444 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PRS_MUTING_CONFIG_VALUE
Parameter name PRS_MUTING_CONFIG_VALUE
Description The value of the PRS muting configuration value. If an operator
enters this value, the eNB forwards the value to the MAC layer.
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word32
Unit NA
Range 0-65535
Read/Write READ/WRITE
Default value 255
Rec. Value 255
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The default value is recommended.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-445


CHAPTER 2. Parameter Description

P_SCM_CODE
Parameter name P_SCM_CODE
Description The primary scramble code of the UTRAN neighbor cell located
near the eNB (for FDD)
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-511
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the scramble Code information of the
Neighboring UTRAN FDD Cell. It is used during Handover with the
UTRAN.
Caution/Note The parameter must be set accurately since it is used during the
Handover.
Delta NA
Real time change Yes
Need to reset No

2-446 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PS_HO_SUPPORT
Parameter name PS_HO_SUPPORT
Description Indicates whether the relevant GERAN neighbor cell supports the
PS-HO.
- False: PS-HO is not supported.
- True: PS-HO is supported.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type enum
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter determines whether or not to execute PS Handover
with the Neighbor GERAN Cell. PS Handover with the Neighbor
GERAN Cell is not executed if the setting is 0. PS Handover with
the Neighbor GERAN Cell is performed if the setting is 1.
Caution/Note The parameter must be set accurately because the PS Handover
execution is determined by the setting.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-447


CHAPTER 2. Parameter Description

PURPOSE
Parameter name PURPOSE
Description The purpose of using the event A1. Currently, it is used to
deactivate the measurement gap.
- ci_A1PurposeMeasGapDeat.: Gap Deactivate.
- ci_A1PurposeSpare_1: Reserved.
- ci_A1PurposeSpare_2: Reserved.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_A1PurposeMeasGapDeat./ci_A1PurposeSpare_1/
ci_A1PurposeSpare_2
Read/Write Read Only
Default value ci_A1PurposeMeasGapDeat.
Rec. Value ci_A1PurposeMeasGapDeat.
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-448 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PURPOSE
Parameter name PURPOSE
Description The purpose of using the event A2. Currently, it is used to activate
the measurement gap and for PS redirection.
- ci_A2PurposeMeasGapAct: Gap Activate.
- ci_A2PurposeRedirection: PS Redirection
- ci_A2PurposeSpare_1: Reserved.
- ci_A2PurposeSpare_2: Reserved.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_A2PurposeMeasGapAct/ci_A2PurposeRedirection/
ci_A2PurposeSpare_1/ci_A2PurposeSpare_2
Read/Write Read Only
Default value ci_A2PurposeMeasGapAct
Rec. Value ci_A2PurposeMeasGapAct
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-449


CHAPTER 2. Parameter Description

PURPOSE
Parameter name PURPOSE
Description The purpose of using the Event A3. Currently, it is used for the intra
LTE handover and SON ANR.
- ci_A3PurposeIntraLteHandover: Intra LTE Handover.
- ci_A3PurposeReportStrongestCells: ICIC.
- ci_A3PurposeSpare_2: Reserved.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_A3PurposeIntraLteHandover/ci_A3PurposeReportStrongestCells/
ci_A3PurposeSpare_2
Read/Write Read Only
Default value ci_A3PurposeIntraLteHandover
Rec. Value ci_A3PurposeIntraLteHandover
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-450 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PURPOSE
Parameter name PURPOSE
Description The purpose of using the Event A4. Currently, it is used for the intra
LTE handover and SON ANR.
- ci_A4PurposeANR_Specific: Used for ANR.
- ci_A4PurposeSpare_1: reserved.
- ci_A4PurposeSpare_2: reserved.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_A4PurposeANR_Specific/ci_A4PurposeSpare_1/
ci_A4PurposeSpare_2
Read/Write Read Only
Default value ci_A4PurposeANR_Specific
Rec. Value ci_A4PurposeANR_Specific
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-451


CHAPTER 2. Parameter Description

PURPOSE
Parameter name PURPOSE
Description The purpose of using the Event A5. Currently, it is not used, but
reserved for use in the future.
- ci_A5PurposeIntraLteHandover: Intra LTE Handover.
- ci_A5PurposeSpare_1: Reserved.
- ci_A5PurposeSpare_2: Reserved.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_A5PurposeIntraLteHandover/ci_A5PurposeSpare_1/
ci_A5PurposeSpare_2
Read/Write Read Only
Default value ci_A5PurposeIntraLteHandover
Rec. Value ci_A5PurposeIntraLteHandover
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-452 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PURPOSE
Parameter name PURPOSE
Description The purpose of using the EUTRA periodic report. Currently, it is
used for ReportStrongestCells (ICIC) and ReportCGI function.
- ci_EutraPeriodicalPurposeReportStrongestCells: ICIC.
- ci_EutraPeriodicalPurposeReportCGI: Report CGI.
- ci_EutraPeriodicalPurposeSpare_1: Reserved.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word32
Unit NA
Range ci_EutraPeriodicalPurposeReportStrongestCells/
ci_EutraPeriodicalPurposeReportCGI/
ci_EutraPeriodicalPurposeSpare_1
Read/Write Read Only
Default value ci_EutraPeriodicalPurposeReportStrongestCells
Rec. Value ci_EutraPeriodicalPurposeReportStrongestCells
Commands RTRV-EUTRA-PRD/CHG-EUTRA-PRD
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-453


CHAPTER 2. Parameter Description

PURPOSE
Parameter name PURPOSE
Description The purpose of using the GERAN B1 event report information.
- ci_B1PurposeInterRatHandover: For inter-RAT Handover
- ci_B1PurposeANR_Specific: Used for ANR.
- ci_B1PurposeSpare_1: reserved.
- ci_B1PurposeSpare_2: reserved.
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_B1PurposeInterRatHandover/ci_B1PurposeANR_Specific/
ci_B1PurposeSpare_1/ci_B1PurposeSpare_2
Read/Write READ only
Default value ci_B1PurposeInterRatHandover
Rec. Value ci_B1PurposeInterRatHandover
Commands RTRV-GERAN-B1CNF/CHG-GERAN-B1CNF
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-454 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PURPOSE
Parameter name PURPOSE
Description The purpose of using the GERAN B2 event report information.
- ci_B2PurposeInterRatHandover: Used for Inter RAT Handover
- ci_B2PurposeSpare_1: reserved.
- ci_B2PurposeSpare_2: reserved.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_B2PurposeInterRatHandover/ci_B2PurposeSpare_1/
ci_B2PurposeSpare_2
Read/Write READ only
Default value ci_B2PurposeInterRatHandover
Rec. Value ci_B2PurposeInterRatHandover
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-455


CHAPTER 2. Parameter Description

PURPOSE
Parameter name PURPOSE
Description The purpose of using the GERAN periodic event report information.
- ci_RatPeriodicalPurposeReportStrongestCells: ICIC.
- ci_RatPeriodicalPurposeReportStrongestCellsForSON: SON.
- ci_RatPeriodicalPurposeReportCGI: Report CGI.
Object class & hierarchy PLDGeranPeriodicInfo
Type Static
Data Type word32
Unit NA
Range ci_RatPeriodicalPurposeReportStrongestCells/
ci_RatPeriodicalPurposeReportStrongestCellsForSON/
ci_RatPeriodicalPurposeReportCGI
Read/Write READ only
Default value ci_RatPeriodicalPurposeReportStrongestCells
Rec. Value ci_RatPeriodicalPurposeReportStrongestCells
Commands RTRV-GERAN-PRD/CHG-GERAN-PRD
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-456 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PURPOSE
Parameter name PURPOSE
Description The purpose of using the UTRA Event B1. Currently, it is used for
the SON ANR function.
- ci_B1PurposeANR_Specific: Used for ANR.
- ci_B1PurposeSpare_1: reserved.
- ci_B1PurposeSpare_2: reserved.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_B1PurposeANR_Specific/ci_B1PurposeSpare_1/
ci_B1PurposeSpare_2
Read/Write READ only
Default value ci_B1PurposeANR_Specific
Rec. Value ci_B1PurposeANR_Specific
Commands RTRV-UTRA-B1CNF/CHG-UTRA-B1CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-457


CHAPTER 2. Parameter Description

PURPOSE
Parameter name PURPOSE
Description The purpose of using the UTRA Event B2. Currently, it is used for
the InterRatHandover handover function.
- ci_B2PurposeInterRatHandover: Used for Inter RAT Handover
- ci_B2PurposeSpare_1: reserved.
- ci_B2PurposeSpare_2: reserved.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word32
Unit NA
Range ci_B2PurposeInterRatHandover/ci_B2PurposeSpare_1/
ci_B2PurposeSpare_2
Read/Write READ only
Default value ci_B2PurposeInterRatHandover
Rec. Value ci_B2PurposeInterRatHandover
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-458 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

PURPOSE
Parameter name PURPOSE
Description The purpose of using the UTRA periodic report. Currently, it is used
for ReportStrongestCells (ICIC), ReportStrongestCellsForSON, and
ReportCGI function.
- ci_RatPeriodicalPurposeReportStrongestCells: ICIC.
- ci_RatPeriodicalPurposeReportStrongestCellsForSON: SON.
- ci_RatPeriodicalPurposeReportCGI: Report CGI.
Object class & hierarchy PLDUtraPeriodicInfo
Type Static
Data Type word32
Unit NA
Range ci_RatPeriodicalPurposeReportStrongestCells/
ci_RatPeriodicalPurposeReportStrongestCellsForSON/
ci_RatPeriodicalPurposeReportCGI
Read/Write READ only
Default value ci_RatPeriodicalPurposeReportStrongestCells
Rec. Value ci_RatPeriodicalPurposeReportStrongestCells
Commands RTRV-UTRA-PRD/CHG-UTRA-PRD
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-459


CHAPTER 2. Parameter Description

2.17 Q
QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDCallPlmnState
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CALLPLMN-STS
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-460 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDCallState
Type Static
Data Type word16
Unit NA
Range 0-255
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CALL-STS
Engineering rules The Index value cannot be changed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDPdcpInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-PDCP-INF/CHG-PDCP-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-461


CHAPTER 2. Parameter Description

QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDQciBhBwInfo
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-BHBW-QCI/CHG-BHBW-QCI
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

QCI
Parameter name QCI
Description The QoS class identifier (QCI) value where the DSCP mapping
information will be specified.
Object class & hierarchy PLDQciDSCPMapInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-QCIDSCP-MAP/CHG-QCIDSCP-MAP
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-462 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-QCACQ-PARA/CHG-QCACQ-PARA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-463


CHAPTER 2. Parameter Description

QCI
Parameter name QCI
Description The QCI index; its range is 0-255.
The standard QCI defined in the standard document is 1-9.
0 and 10-255 can be used by an operator optionally.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write READ only
Default value 0
Rec. Value 0
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

Q_HYST
Parameter name Q_HYST
Description In the cell reselection criteria, it is the offset value added to the
current serving cell. ci_q_Hyst_dB1 means the 1dB; and
ci_q_Hyst_dB2 means the 2 dB.
Object class & hierarchy PLDCellReselectInfoLogic
Type Static
Data Type short
Unit dB
Range 0-15
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-RSEL/CHG-CELL-RSEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-464 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

Q_HYST_SFHIGH
Parameter name Q_HYST_SFHIGH
Description As for the Qhyst added to the current serving cell in the cell
reselection criteria, it is the value added when the UE speed is
high.
ci_Q_HystSF_dB_6 means -6dB and ci_Q_HystSF_dB_4 means -
4dB.
To apply the change of this parameter, the
SPEED_STATE_RESEL_PARAMS_USAGE should be changed to
1 in the CHG-MOBIL-STA beforehand.
Object class & hierarchy PLDCellReselectInfoLogic
Type Static
Data Type short
Unit dB
Range 0-3
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-RSEL/CHG-CELL-RSEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-465


CHAPTER 2. Parameter Description

Q_HYST_SFMEDIUM
Parameter name Q_HYST_SFMEDIUM
Description As for the Qhyst added to the current serving cell in the cell
reselection criteria, it is the value added when the UE speed is
medium. To apply the change of this parameter, the
SPEED_STATE_RESEL_PARAMS_USAGE should be changed to
1 in the CHG-MOBIL-STA beforehand.
Object class & hierarchy PLDCellReselectInfoLogic
Type Static
Data Type short
Unit dB
Range 0-3
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-CELL-RSEL/CHG-CELL-RSEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-466 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

QOFFSET_CELL
Parameter name QOFFSET_CELL
Description The cell quality offset value to be applied to the E-UTRAN neighbor
cell located near the eNB. It is used for cell re-selection by the UE
in the RRC idle mode.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type enum
Unit dB
Range ci_dB_24/ci_dB_22/ci_dB_20/ci_dB_18/ci_dB_16/ci_dB_14/
ci_dB_12/ci_dB_10/ci_dB_8/ci_dB_6/ci_dB_5/ci_dB_4/ci_dB_3/
ci_dB_2/ci_dB_1/ci_dB0/ci_dB1/ci_dB2/ci_dB3/ci_dB4/ci_dB5/
ci_dB6/ci_dB8/ci_dB10/ci_dB12/ci_dB14/ci_dB16/ci_dB18/
ci_dB20/ci_dB22/ci_dB24
Read/Write READ/WRITE
Default value ci_dB0
Rec. Value ci_dB0
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN /CRTE-NBR-
EUTRAN/DLT-NBR-EUTRAN
Engineering rules This parameter indicates the quality offset value of the Neighbor
EUTRAN Cell. This information is used during Cell reselection
operations by the UE in an Idle state.
ci_dB_24 = 0, /* display_name: ‘ci_dB-24’ */
ci_dB_22 = 1, /* display_name: ‘ci_dB-22’ */
ci_dB_20 = 2, /* display_name: ‘ci_dB-20’ */
ci_dB_18 = 3, /* display_name: ‘ci_dB-18’ */
ci_dB_16 = 4, /* display_name: ‘ci_dB-16’ */
ci_dB_14 = 5, /* display_name: ‘ci_dB-14’ */
ci_dB_12 = 6, /* display_name: ‘ci_dB-12’ */
ci_dB_10 = 7, /* display_name: ‘ci_dB-10’ */
ci_dB_8 = 8, /* display_name: ‘ci_dB-8’ */
ci_dB_6 = 9, /* display_name: ‘ci_dB-6’ */
ci_dB_5 = 10, /* display_name: ‘ci_dB-5’ */
ci_dB_4 = 11, /* display_name: ‘ci_dB-4’ */
ci_dB_3 = 12, /* display_name: ‘ci_dB-3’ */
ci_dB_2 = 13, /* display_name: ‘ci_dB-2’ */
ci_dB_1 = 14, /* display_name: ‘ci_dB-1’ */
ci_dB0 = 15,
ci_dB1 = 16,
ci_dB2 = 17,
ci_dB3 = 18,
ci_dB4 = 19,
ci_dB5 = 20,
ci_dB6 = 21,

© SAMSUNG Electronics Co., Ltd. 2-467


CHAPTER 2. Parameter Description

(Continued)

Engineering rules ci_dB8 = 22,


ci_dB10 = 23,
ci_dB12 = 24,
ci_dB14 = 25,
ci_dB16 = 26,
ci_dB18 = 27,
ci_dB20 = 28,
ci_dB22 = 29,
ci_dB24 = 30
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-468 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

Q_OFFSET_FREQ
Parameter name Q_OFFSET_FREQ
Description The frequency offset value which is applied to the q-OffsetFreq in
the SIB5 message.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range ci_dB_24/ci_dB_22/ci_dB_20/ci_dB_18/ci_dB_16/ci_dB_14/
ci_dB_12/ci_dB_10/ci_dB_8/ci_dB_6/ci_dB_5/ci_dB_4/ci_dB_3/
ci_dB_2/ci_dB_1/ci_dB0/ci_dB1/ci_dB2/ci_dB3/ci_dB4/ci_dB5/
ci_dB6/ci_dB8/ci_dB10/ci_dB12/ci_dB14/ci_dB16/ci_dB18/
ci_dB20/ci_dB22/ci_dB24
Read/Write READ/WRITE
Default value ci_dB0
Rec. Value ci_dB0
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used in SystemInformationBlockType5 message.
The qOffsetFreq is used to indicate afrequency specific offset to be
applied when evaluating candidates for cell re-selection or when
evaluating triggering conditions for measurement reporting.
The value in dB. Value dB-24 corresponds to -24 dB, dB-22
corresponds to -22 dB and so on.
ci_dB_24 = 0, /* display_name: ‘ci_dB-24’ */
ci_dB_22 = 1, /* display_name: ‘ci_dB-22’ */
ci_dB_20 = 2, /* display_name: ‘ci_dB-20’ */
ci_dB_18 = 3, /* display_name: ‘ci_dB-18’ */
ci_dB_16 = 4, /* display_name: ‘ci_dB-16’ */
ci_dB_14 = 5, /* display_name: ‘ci_dB-14’ */
ci_dB_12 = 6, /* display_name: ‘ci_dB-12’ */
ci_dB_10 = 7, /* display_name: ‘ci_dB-10’ */
ci_dB_8 = 8, /* display_name: ‘ci_dB-8’ */
ci_dB_6 = 9, /* display_name: ‘ci_dB-6’ */
ci_dB_5 = 10, /* display_name: ‘ci_dB-5’ */
ci_dB_4 = 11, /* display_name: ‘ci_dB-4’ */
ci_dB_3 = 12, /* display_name: ‘ci_dB-3’ */
ci_dB_2 = 13, /* display_name: ‘ci_dB-2’ */
ci_dB_1 = 14, /* display_name: ‘ci_dB-1’ */
ci_dB0 = 15,
ci_dB1 = 16,
ci_dB2 = 17,
ci_dB3 = 18,
ci_dB4 = 19,
ci_dB5 = 20,

© SAMSUNG Electronics Co., Ltd. 2-469


CHAPTER 2. Parameter Description

(Continued)

Engineering rules ci_dB6 = 21,


ci_dB8 = 22,
ci_dB10 = 23,
ci_dB12 = 24,
ci_dB14 = 25,
ci_dB16 = 26,
ci_dB18 = 27,
ci_dB20 = 28,
ci_dB22 = 29,
ci_dB24 = 30
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-470 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

QOS_CAC_OPTION
Parameter name QOS_CAC_OPTION
Description Indicates whether to perform the call admission control (CAC)
based on the quality of service (QoS) of each cell.
- QoSCAC_option0: QoS based CAC function is not performed for
each cell.
- QoSCAC_option1: QoS based CAC function is performed for
each cell.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range QoSCAC_option0/QoSCAC_option1
Read/Write READ/WRITE
Default value QoSCAC_option1
Rec. Value QoSCAC_option1
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the parameter that determines whether or not QoS based
CAC is executed. If the parameter is set to QoSCAC_option0, then
QoS CAC is not executed. If it is set to QoSCAC_option1, then
QoS CAC is executed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-471


CHAPTER 2. Parameter Description

QOS_POLICY_OPTION
Parameter name QOS_POLICY_OPTION
Description It is the policy on performing the call admission control (CAC)
based on the quality of service (QoS) of each cell.
- QoSPolicy_option0: For the newly requested GBR bearer, the
PRB usage is calculated based on the resource type (GBR, non-
GBR) of the QCI to perform the CAC; and all the non-GBR is
accepted.
- QoSPolicy_option1: For the newly requested GBR bearer, the
PRB usage is calculated based on the priority of the QCI to
perform the CAC; and all the non-GBR is accepted.
Object class & hierarchy PLDCellCacInfoFunc
Type Static
Data Type word16
Unit NA
Range QoSPolicy_option0/QoSPolicy_option1
Read/Write READ/WRITE
Default value QoSPolicy_option1
Rec. Value QoSPolicy_option1
Commands RTRV-CELL-CAC/CHG-CELL-CAC
Engineering rules This is the parameter that determines the QoS CAC policy. If this
parameter is set to QoSPolicy_option0, then CAC for the priority
higher than the standard priority is executed. Of it is set to
QoSPolicy_option1, then CAC for the priority higher than the
current ERAB priority is executed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-472 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

Q_QUAL_MIN
Parameter name Q_QUAL_MIN
Description In the cell selection criteria, it is the threshold value added to the
currently measured cell (in dB).
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type int
Unit NA
Range -34 to -3
Read/Write READ/WRITE
Default value -16
Rec. Value -16
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

Q_QUAL_MIN
Parameter name Q_QUAL_MIN
Description The minimum quality level required by the UTRA FDD cell.
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type int
Unit NA
Range -24 to 0
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-473


CHAPTER 2. Parameter Description

Q_QUAL_MIN
Parameter name Q_QUAL_MIN
Description The minimum quality level required by the UTRA FDD cell.
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range -24 to 0
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

Q_QUAL_MIN_OFFSET
Parameter name Q_QUAL_MIN_OFFSET
Description It is the offset value added to the qQualMin in the cell selection
criteria (in dB).
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type word32
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 3
Rec. Value 3
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-474 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

Q_QUAL_MIN_OFFSET_USAGE
Parameter name Q_QUAL_MIN_OFFSET_USAGE
Description Indicates whether to use the offset value added to the qQualMin in
the call selection criteria.
- CI_no_use: qQualMinOffset value is not added to the qQualMin.
- CI_use: qQualMinOffset is added to the qQualMin.
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

Q_QUAL_MIN_REL9
Parameter name Q_QUAL_MIN_REL9
Description The qQualMin value for Rel-9
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range -34 to -3
Read/Write READ/WRITE
Default value -3
Rec. Value -3
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is minimum required qualitylevel in the cell (dB).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-475


CHAPTER 2. Parameter Description

Q_QUAL_MIN_REL9_USAGE
Parameter name Q_QUAL_MIN_REL9_USAGE
Description Indicates whether to use the qQualMin value for Rel-9.
- CI_no_use: qQualMin is not used.
- CI_use: qQualMin is used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter determines whether or not the system should use
qQualMinRel9.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

Q_RXLEV_MIN
Parameter name Q_RXLEV_MIN
Description In the cell selection criteria, it is the threshold value added to the
currently measured cell.
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type int
Unit dBm
Range -70 to -22
Read/Write READ/WRITE
Default value -64
Rec. Value -64
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-476 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

Q_RX_LEV_MIN
Parameter name Q_RX_LEV_MIN
Description Minimum Rx level required in the cell (in dBm).
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dBm
Range -70 to -22
Read/Write READ/WRITE
Default value -64
Rec. Value -64
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The qRxLevmin is used to indicate for cell selection/re-selection
the required minimum received RSRP level in the (E-UTRA) cell.
Corresponds to parameter Qrxlevmin in 3GPP TS 36.304. Actual
value Qrxlevmin = IE value * 2 [dBm].
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

Q_RX_LEV_MIN
Parameter name Q_RX_LEV_MIN
Description Minimum Rx level required in the cell (in dBm).
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type int
Unit dBm
Range -60 to-13
Read/Write READ/WRITE
Default value -50
Rec. Value -50
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-477


CHAPTER 2. Parameter Description

Q_RX_LEV_MIN
Parameter name Q_RX_LEV_MIN
Description Minimum Rx level required in the cell (in dBm).
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit dBm
Range -60 to-13
Read/Write READ/WRITE
Default value -50
Rec. Value -50
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

Q_RXLEV_MIN_OFFSET
Parameter name Q_RXLEV_MIN_OFFSET
Description It is the offset value added to the qRxlevmin in the cell selection
criteria.
Range is 1-8; 1 means 2 dB and 8 means 16 dB (IE value*2[dB]).
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type short
Unit NA
Range 1-8
Read/Write READ/WRITE
Default value 3
Rec. Value 3
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-478 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

Q_RXLEV_MIN_OFFSET_USAGE
Parameter name Q_RXLEV_MIN_OFFSET_USAGE
Description Indicates whether to use the offset value added to the qRxlevmin in
the cell selection criteria.
- CI_no_use: qRxlevminoffset value is not added to qRxlevmin.
- CI_use: qRxlevminoffset is added to qRxlevmin.
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type short
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-479


CHAPTER 2. Parameter Description

2.18 R
RAC
Parameter name RAC
Description The routing area code of the GERAN neighbor cell located near
the eNB.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type byte
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the routing area code of the Neighbor
GERAN Cell. This information is used during RIM procedures and
Handover.
Caution/Note The parameter must be set accurately because the information is
used during RIM procedures and Handover.
Delta NA
Real time change Yes
Need to reset No

2-480 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RAC
Parameter name RAC
Description The routing area code of the UTRAN neighbor cell located near the
eNB.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type byte
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the routing area code of the Neighbor
UTRAN Cell. This information is used during RIM procedures and
Handover.
Caution/Note The parameter must be set accurately because the information is
used during RIM procedures and Handover.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-481


CHAPTER 2. Parameter Description

RECOVERY_MODE_SELECTION
Parameter name RECOVERY_MODE_SELECTION
Description Information indicating whether to perform automatic recovery when
an alarm is generated as a result of diagnosis call.
Object class & hierarchy PLDDiagCallConf
Type Static
Data Type word32
Unit NA
Range MANUAL/AUTO
Read/Write READ/WRITE
Default value AUTO
Rec. Value AUTO
Commands RTRV-DIAG-CONF, CHG-DIAG-CONF
Engineering rules AUTO (1): Action is taken per the procedure provided by the
system.
MANUAL (0): Only alarm is generated so that an operator can take
action manually.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-482 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REL9_SEL_INFO_USAGE
Parameter name REL9_SEL_INFO_USAGE
Description Indicates whether to use the Rel. 9 selectionInfo parameter of the
cell in the eNB.
- CI_no_use: Rel. 9 selectionInfo parameter is not used.
- CI_use: Rel. 9 selectionInfo parameter is used.
Object class & hierarchy PLDCellSelectInfoLogic
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-CELL-SEL/CHG-CELL-SEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-483


CHAPTER 2. Parameter Description

RELATION_IDX
Parameter name RELATION_IDX
Description The DB index of the E-UTRAN neighbor cell.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word32
Unit NA
Range 0-255
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Index of the registered Neighbor
EUTRAN Cell.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

RELATION_IDX
Parameter name RELATION_IDX
Description Indicates the DB index of the GERAN neighbor cell located near
the eNB.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range 0-255
Read/Write READ Only
Default value 0
Rec. Value 0
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the Index of the registered Neighbor
GERAN Cell.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-484 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RELATION_IDX
Parameter name RELATION_IDX
Description The DB index of the UTRAN neighbor cell.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range 0-255
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the Index of the registered Neighbor
GERAN Cell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

RELOCATE_HOCOUNT
Parameter name RELOCATE_HOCOUNT
Description The relocated handover count.
Object class & hierarchy PLDCcUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CC-UECNT
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-485


CHAPTER 2. Parameter Description

RELOCATE_HOCOUNT
Parameter name RELOCATE_HOCOUNT
Description The relocated handover count
Object class & hierarchy PLDCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-CELL-UECNT
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

RELOCATE_HOCOUNT
Parameter name RELOCATE_HOCOUNT
Description The relocated handover count
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-486 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RELOCATE_HOCOUNT
Parameter name RELOCATE_HOCOUNT
Description The relocated handover count
Object class & hierarchy PLDSystemUeCnt
Type Static
Data Type word32
Unit NA
Range 0-4294967295
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-SYS-UECNT
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

REMOTE_FLAG
Parameter name REMOTE_FLAG
Description The field indicating if the neighbor eNB is managed by the same
EMS or different EMS.
- False: Belongs to a different EMS.
- True: Belongs to the same EMS.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates whether the registered Neighbor ENB
belongs to the same or different EMS.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-487


CHAPTER 2. Parameter Description

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the Event A1.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_infinity
Rec. Value ci_reportAmount_infinity
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event A1) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_reportAmount_r1 = 0,
ci_reportAmount_r2 = 1,
ci_reportAmount_r4 = 2,
ci_reportAmount_r8 = 3,
ci_reportAmount_r16 = 4,
ci_reportAmount_r32 = 5,
ci_reportAmount_r64 = 6,
ci_reportAmount_infinity = 7
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-488 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the Event A2.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_infinity
Rec. Value ci_reportAmount_infinity
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event A2) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_reportAmount_r1 = 0,
ci_reportAmount_r2 = 1,
ci_reportAmount_r4 = 2,
ci_reportAmount_r8 = 3,
ci_reportAmount_r16 = 4,
ci_reportAmount_r32 = 5,
ci_reportAmount_r64 = 6,
ci_reportAmount_infinity = 7
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-489


CHAPTER 2. Parameter Description

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the Event A3.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_infinity
Rec. Value ci_reportAmount_infinity
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event A3) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_reportAmount_r1 = 0,
ci_reportAmount_r2 = 1,
ci_reportAmount_r4 = 2,
ci_reportAmount_r8 = 3,
ci_reportAmount_r16 = 4,
ci_reportAmount_r32 = 5,
ci_reportAmount_r64 = 6,
ci_reportAmount_infinity = 7
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-490 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the Event A4.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r8
Rec. Value ci_reportAmount_r8
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event A4) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_reportAmount_r1 = 0,
ci_reportAmount_r2 = 1,
ci_reportAmount_r4 = 2,
ci_reportAmount_r8 = 3,
ci_reportAmount_r16 = 4,
ci_reportAmount_r32 = 5,
ci_reportAmount_r64 = 6,
ci_reportAmount_infinity = 7
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-491


CHAPTER 2. Parameter Description

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_infinity
Rec. Value ci_reportAmount_infinity
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event A5) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_reportAmount_r1 = 0,
ci_reportAmount_r2 = 1,
ci_reportAmount_r4 = 2,
ci_reportAmount_r8 = 3,
ci_reportAmount_r16= 4,
ci_reportAmount_r32 = 5,
ci_reportAmount_r64 = 6,
ci_reportAmount_infinity = 7
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-492 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the EUTRA periodic report.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_infinity
Rec. Value ci_reportAmount_infinity
Commands RTRV-EUTRA-PRD/CHG-EUTRA-PRD
Engineering rules This parameter is for setting the number of Measurement Reports
(Periodic) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the active
UE while changing parameters. Apply the new setting to the UE
during a new connection request (e.g., Attach or Idle to Active)
ci_reportAmount_r1 = 0,
ci_reportAmount_r2 = 1,
ci_reportAmount_r4 = 2,
ci_reportAmount_r8 = 3,
ci_reportAmount_r16 = 4,
ci_reportAmount_r32 = 5,
ci_reportAmount_r64 = 6,
ci_reportAmount_infinity = 7
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-493


CHAPTER 2. Parameter Description

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description Total number of the measurement reports by the UE through the
GERAN B1 event report
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r1
Rec. Value ci_reportAmount_r1
Commands RTRV-GERAN-B1CNF/CHG-GERAN-B1CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event B1) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-494 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description Total number of the measurement reports by the UE through the
GERAN B2 event report
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r1
Rec. Value ci_reportAmount_r1
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event B2) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-495


CHAPTER 2. Parameter Description

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description Maximum number of the measurement reports by the UE due to
the GERAN Periodic event report
Object class & hierarchy PLDGeranPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r16
Rec. Value ci_reportAmount_r16
Commands RTRV-GERAN-PRD/CHG-GERAN-PRD
Engineering rules This parameter is for setting the number of Measurement Reports
(Periodic) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-496 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the UTRA Event B1.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r1
Rec. Value ci_reportAmount_r1
Commands RTRV-UTRA-B1CNF/CHG-UTRA-B1CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event B1) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-497


CHAPTER 2. Parameter Description

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the UTRA Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r1
Rec. Value ci_reportAmount_r1
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules This parameter is for setting the number of Measurement Reports
(Event B2) for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-498 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_AMOUNT
Parameter name REPORT_AMOUNT
Description The number of measurement reports for the UTRA periodic report.
Object class & hierarchy PLDUtraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_reportAmount_r1/ci_reportAmount_r2/ci_reportAmount_r4/
ci_reportAmount_r8/ci_reportAmount_r16/ci_reportAmount_r32/
ci_reportAmount_r64/ci_reportAmount_infinity
Read/Write READ/WRITE
Default value ci_reportAmount_r16
Rec. Value ci_reportAmount_r16
Commands RTRV-UTRA-PRD/CHG-UTRA-PRD
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-499


CHAPTER 2. Parameter Description

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the Event A1.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms480
Rec. Value ci_ReportInterval_ms480
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules This parameter is for setting the Measurement Report transmission
interval when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_ReportInterval_ms120 = 0,
ci_ReportInterval_ms240 = 1,
ci_ReportInterval_ms480 = 2,
ci_ReportInterval_ms640 = 3,
ci_ReportInterval_ms1024 = 4,
ci_ReportInterval_ms2048 = 5,
ci_ReportInterval_ms5120 = 6,
ci_ReportInterval_ms10240 = 7,
ci_ReportInterval_min1 = 8,
ci_ReportInterval_min6 = 9,
ci_ReportInterval_min12 = 10,
ci_ReportInterval_min30 = 11,
ci_ReportInterval_min60 = 12
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-500 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the Event A2.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms480
Rec. Value ci_ReportInterval_ms480
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules This parameter is for setting the Measurement Report transmission
interval when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_ReportInterval_ms120 = 0,
ci_ReportInterval_ms240 = 1,
ci_ReportInterval_ms480 = 2,
ci_ReportInterval_ms640 = 3,
ci_ReportInterval_ms1024 = 4,
ci_ReportInterval_ms2048 = 5,
ci_ReportInterval_ms5120 = 6,
ci_ReportInterval_ms10240 = 7,
ci_ReportInterval_min1 = 8,
ci_ReportInterval_min6 = 9,
ci_ReportInterval_min12 = 10,
ci_ReportInterval_min30 = 11,
ci_ReportInterval_min60 = 12
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-501


CHAPTER 2. Parameter Description

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the Event A3.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms480
Rec. Value ci_ReportInterval_ms480
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules This parameter is for setting the Measurement Report transmission
interval when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_ReportInterval_ms120 = 0,
ci_ReportInterval_ms240 = 1,
ci_ReportInterval_ms480 = 2,
ci_ReportInterval_ms640 = 3,
ci_ReportInterval_ms1024 = 4,
ci_ReportInterval_ms2048 = 5,
ci_ReportInterval_ms5120 = 6,
ci_ReportInterval_ms10240 = 7,
ci_ReportInterval_min1 = 8,
ci_ReportInterval_min6 = 9,
ci_ReportInterval_min12 = 10,
ci_ReportInterval_min30 = 11,
ci_ReportInterval_min60 = 12
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-502 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the Event A4.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules This parameter is for setting the Measurement Report transmission
interval when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_ReportInterval_ms120 = 0,
ci_ReportInterval_ms240 = 1,
ci_ReportInterval_ms480 = 2,
ci_ReportInterval_ms640 = 3,
ci_ReportInterval_ms1024 = 4,
ci_ReportInterval_ms2048 = 5,
ci_ReportInterval_ms5120 = 6,
ci_ReportInterval_ms10240 = 7,
ci_ReportInterval_min1 = 8,
ci_ReportInterval_min6 = 9,
ci_ReportInterval_min12 = 10,
ci_ReportInterval_min30 = 11,
ci_ReportInterval_min60 = 12
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-503


CHAPTER 2. Parameter Description

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the Event A5.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms480
Rec. Value ci_ReportInterval_ms480
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules This parameter is for setting the Measurement Report transmission
interval when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_ReportInterval_ms120 = 0,
ci_ReportInterval_ms240 = 1,
ci_ReportInterval_ms480 = 2,
ci_ReportInterval_ms640 = 3,
ci_ReportInterval_ms1024 = 4,
ci_ReportInterval_ms2048 = 5,
ci_ReportInterval_ms5120 = 6,
ci_ReportInterval_ms10240 = 7,
ci_ReportInterval_min1 = 8,
ci_ReportInterval_min6 = 9,
ci_ReportInterval_min12 = 10,
ci_ReportInterval_min30 = 11,
ci_ReportInterval_min60 = 12
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-504 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the EUTRA periodic report.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-EUTRA-PRD/CHG-EUTRA-PRD
Engineering rules This parameter is for setting the Measurement Report transmission
interval when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_ReportInterval_ms120 = 0,
ci_ReportInterval_ms240 = 1,
ci_ReportInterval_ms480 = 2,
ci_ReportInterval_ms640 = 3,
ci_ReportInterval_ms1024 = 4,
ci_ReportInterval_ms2048 = 5,
ci_ReportInterval_ms5120 = 6,
ci_ReportInterval_ms10240 = 7,
ci_ReportInterval_min1 = 8,
ci_ReportInterval_min6 = 9,
ci_ReportInterval_min12 = 10,
ci_ReportInterval_min30 = 11,
ci_ReportInterval_min60 = 12
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-505


CHAPTER 2. Parameter Description

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of the measurement reports by the UE through the
GERAN B1 event report
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-GERAN-B1CNF/CHG-GERAN-B1CNF
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-506 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of the measurement reports by the UE through the
GERAN B2 event report
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-507


CHAPTER 2. Parameter Description

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of the measurement reports by the UE due to the
GERAN Periodic event report
Object class & hierarchy PLDGeranPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-GERAN-PRD/CHG-GERAN-PRD
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-508 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the UTRA Event B1.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-UTRA-B1CNF/CHG-UTRA-B1CNF
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-509


CHAPTER 2. Parameter Description

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the UTRA Event B2.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-510 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_INTERVAL
Parameter name REPORT_INTERVAL
Description The interval of measurement reports for the UTRA periodic report.
Object class & hierarchy PLDUtraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_ReportInterval_ms120/ci_ReportInterval_ms240/
ci_ReportInterval_ms480/ci_ReportInterval_ms640/
ci_ReportInterval_ms1024/ci_ReportInterval_ms2048/
ci_ReportInterval_ms5120/ci_ReportInterval_ms10240/
ci_ReportInterval_min1/ci_ReportInterval_min6/
ci_ReportInterval_min12/ci_ReportInterval_min30/
ci_ReportInterval_min60
Read/Write READ/WRITE
Default value ci_ReportInterval_ms240
Rec. Value ci_ReportInterval_ms240
Commands RTRV-UTRA-PRD/CHG-UTRA-PRD
Engineering rules This parameter is for setting the number of Measurement Reports
for a device reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-511


CHAPTER 2. Parameter Description

REPORT_QUANTITY
Parameter name REPORT_QUANTITY
Description The information on quantity included in the measurement report for
the Event A1. It can be specified to be the same as the trigger
quantity, or to contain both RSRP and RSRQ value.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_sameAsTriggerQuantity/ci_both
Read/Write READ/WRITE
Default value ci_both
Rec. Value ci_both
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules This parameter is for setting whether to report only values equal to
the triggerQuantity (RSRP or RSRQ), or all values (RSRP and
RSRQ), when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_sameAsTriggerQuantity = 0,
ci_both = 1
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-512 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_QUANTITY
Parameter name REPORT_QUANTITY
Description The information on quantity included in the measurement report for
the Event A2. It can be specified to be the same as the trigger
quantity, or to contain both RSRP and RSRQ value.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_sameAsTriggerQuantity/ci_both
Read/Write READ/WRITE
Default value ci_both
Rec. Value ci_both
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules This parameter is for setting whether to report only values equal to
the triggerQuantity (RSRP or RSRQ), or all values (RSRP and
RSRQ), when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_sameAsTriggerQuantity = 0,
ci_both = 1
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-513


CHAPTER 2. Parameter Description

REPORT_QUANTITY
Parameter name REPORT_QUANTITY
Description The information on quantity included in the measurement report for
the Event A3. It can be specified to be the same as the trigger
quantity, or to contain both RSRP and RSRQ value.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_sameAsTriggerQuantity/ci_both
Read/Write READ/WRITE
Default value ci_both
Rec. Value ci_both
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules This parameter is for setting whether to report only values equal to
the triggerQuantity (RSRP or RSRQ), or all values (RSRP and
RSRQ), when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_sameAsTriggerQuantity = 0,
ci_both = 1
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-514 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_QUANTITY
Parameter name REPORT_QUANTITY
Description The information on quantity included in the measurement report for
the Event A4. It can be specified to be the same as the trigger
quantity, or to contain both RSRP and RSRQ value.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_sameAsTriggerQuantity/ci_both
Read/Write READ/WRITE
Default value ci_both
Rec. Value ci_both
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules This parameter is for setting whether to report only values equal to
the triggerQuantity (RSRP or RSRQ), or all values (RSRP and
RSRQ), when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_sameAsTriggerQuantity = 0,
ci_both = 1
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-515


CHAPTER 2. Parameter Description

REPORT_QUANTITY
Parameter name REPORT_QUANTITY
Description The information on quantity included in the measurement report for
the Event A5. It can be specified to be the same as the trigger
quantity, or to contain both RSRP and RSRQ value.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_sameAsTriggerQuantity/ci_both
Read/Write READ/WRITE
Default value ci_both
Rec. Value ci_both
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules This parameter is for setting whether to report only values equal to
the triggerQuantity (RSRP or RSRQ), or all values (RSRP and
RSRQ), when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_sameAsTriggerQuantity = 0,
ci_both = 1
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-516 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

REPORT_QUANTITY
Parameter name REPORT_QUANTITY
Description The information on quantity included in the measurement report for
the EUTRA periodic report. It can be specified to be the same as
the trigger quantity, or to contain both RSRP and RSRQ value.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_sameAsTriggerQuantity/ci_both
Read/Write READ/WRITE
Default value ci_sameAsTriggerQuantity
Rec. Value ci_sameAsTriggerQuantity
Commands RTRV-EUTRA-PRD/CHG-EUTRA-PRD
Engineering rules This parameter is for setting whether to report only values equal to
the triggerQuantity (RSRP or RSRQ), or all values (RSRP and
RSRQ), when a device is reporting measurement results.
A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
ci_sameAsTriggerQuantity = 0,
ci_both = 1
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-517


CHAPTER 2. Parameter Description

RESEL_PRIORITY_USAGE
Parameter name RESEL_PRIORITY_USAGE
Description Indicates whether to use the cellReselectionPriority of SIB6.
- CI_no_use: There is no reselection priority for carriers in the
UTRAN.
- CI_use: There is reselection priority for carriers in the UTRAN.
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type enum
Unit NA
Range CI_no_use/CI_use
Read/Write READ/WRITE
Default value CI_use
Rec. Value CI_use
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-518 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RESOURCE_TYPE
Parameter name RESOURCE_TYPE
Description The resource type of the QoS class identifier (QCI).
- ci_NonGBR: Sets the resource type of the QCI to non-GBR
(Guaranteed Bit Rate).
- ci_GBR: Sets the resource type of the QCI to GBR (Guaranteed
Bit Rate).
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range ci_NonGBR/ci_GBR
Read/Write READ/WRITE
Default value ci_NonGBR
Rec. Value ci_NonGBR
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-519


CHAPTER 2. Parameter Description

RIM_ENABLE
Parameter name RIM_ENABLE
Description Indicates whether to enable the RIM procedure.
Object class & hierarchy PLDHandoverOptionInfoFunc
Type Static
Data Type int
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-HO-OPT/CHG-HO-OPT
Engineering rules This parameter is used to determine whether or not to execute RIM
to the MME. If the parameter is set to 1, then RIM is executed.
- False: RIM process is not executed.
- True: RIM process is executed.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

RIM_RIAE
Parameter name RIM_RIAE
Description The time waiting for response after sending the MME Direct
Information Transfer (RAN-INFORMATION-APPLICATION-
ERROR) to the MINE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-520 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RIM_RIR
Parameter name RIM_RIR
Description The time waiting for response after sending the MME Direct
Information Transfer (RAN-INFORMATION-REQUEST) to the
MINE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write READ/WRITE
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-521


CHAPTER 2. Parameter Description

RIM_STATUS
Parameter name RIM_STATUS
Description Indicates the RIM connection status.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type enum
Unit NA
Range Not_Connected/Init_Requesting/Stop_Requesting/Connected
Read/Write READ/WRITE
Default value Not_Connected
Rec. Value Not_Connected
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This information indicates the Neighbor GERAN Cell and RIM
status. It shows as Connected if the SI information is normally
obtained through RIM operation, and Not_Connected if the
information is not obtained at all.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-522 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RIM_SUPPORT
Parameter name RIM_SUPPORT
Description Indicates whether the relevant GERAN neighbor cell supports the
RIM.
- False: RIM is not supported.
- True: RIM is supported.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write READ/WRITE
Default value True
Rec. Value True
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates whether or not the RIM procedure of a
Neighbor GERAN Cell is supported. If it is set to False, then the
RIM procedure is not executed. If it is set to True, then the RIM
procedure is executed.
Caution/Note It must be set accurately since the RIM procedure execution is
determined by the setting.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-523


CHAPTER 2. Parameter Description

RIM_SUPPORT
Parameter name RIM_SUPPORT
Description Indicates whether the UTRAN neighbor cell supports the RIM.
- False: RIM is not supported.
- True: RIM is supported.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range False/True
Read/Write READ/WRITE
Default value False
Rec. Value False
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates whether or not the RIM procedure of a
Neighbor UTRAN Cell is supported. If it is set to False, then the
RIM procedure is not executed. If it is set to True, then the RIM
procedure is executed.
Caution/Note It must be set accurately since the RIM procedure execution is
determined by the setting.
Delta NA
Real time change Yes
Need to reset No

2-524 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RNC_ID
Parameter name RNC ID
Description Indicates the RNC ID of the UTRAN neighbor cell located near the
eNB.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range 0-4095
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the RNC information of the Neighboring
UTRAN Cell. The information is used during RIM operation and
during Handover.
Caution/Note The RNC ID information for the Neighboring UTRAN Cell must be
set accurately.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-525


CHAPTER 2. Parameter Description

RNC_ID
Parameter name RNC ID
Description Indicates the RNC ID of the UTRAN neighbor cell located near the
eNB.
Object class & hierarchy PLDRimControl
Type NA
Data Type word32
Unit Static
Range 0-4095
Read/Write READ/WRITE
Default value 0
Rec. Value 0
Commands RTRV-RIM-CONTROL/CHG-RIM-CONTROL
Engineering rules This is used when executing RIM.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

ROHC_SUPPORT
Parameter name ROHC SUPPORT
Description Indicates whether to support the ROHC.
- Fault: ROHC is not used (default).
- True: ROHC is used.
Object class & hierarchy PLDRohcInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write Read/Write
Default value False
Rec. Value False
Commands RTRV-ROHC-INF/CHG-ROHC-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-526 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RRC_CONNECTION_RECONFIG
Parameter name RRC_CONNECTION_RECONFIG
Description The waiting time until the RrcConnectionRecofigurationComplete
message is received after the eNB sends the
RrcConnectionRecofig message to the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 1500
Rec. Value 1500
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value used for all Reconfiguration (Attach,
Handover, Phy Modify) processes.
Caution/Note Precautions must be taken when changing the value since it is an
optimized timer setting.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-527


CHAPTER 2. Parameter Description

RRC_CONNECTION_RE_ESTABLISH
Parameter name RRC_CONNECTION_RE_ESTABLISH
Description The waiting time until the RrcConnectionReestablishmentComplete
message is received after the eNB sends the
RrcConnectionReestablishment message to the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for receiving the RRC Connection
Reestablishment Complete message after transmitting the RRC
Connection Reestablishment request. The call is disconnected
once the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-528 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RRC_CONNECTION_RELEASE
Parameter name RRC_CONNECTION_RELEASE
Description The waiting time until the PDCB receives the message confirming
that the message was sent to the UE after the eNB sends the
RrcConnectionRelease message to the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 100
Rec. Value 100
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value for receiving the device transmission
confirmation from the PDCB for the transmission of the RRC
Connection Release message. It does not affect the Call process.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-529


CHAPTER 2. Parameter Description

RRC_CONNECTION_SETUP
Parameter name RRC_CONNECTION_SETUP
Description The waiting time until the RrcConnectionSetupComplete message
is received after the eNB sends the RrcConnectionSetup message
to the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 1000
Rec. Value 1000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules Rec.Value is the optimized timer setting. Usage of the Rec.Value is
recommended.
Caution/Note Please note that changing the timer setting may affect the RRC
connection attempt count and success rate.
Delta NA
Real time change Yes
Need to reset No

2-530 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RRC_HANDOVER_PREPARATION
Parameter name RRC_HANDOVER_PREPARATION
Description The waiting time until the RrcULHandoverPreparationTransfer
message is received after the eNB sends the
RrcHandoverFromEUTRAPreparationRequest message to the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer used during the preparation process for the
Handover.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-531


CHAPTER 2. Parameter Description

RRC_SECURITY_MODE_COMMAND
Parameter name RRC_SECURITY_MODE_COMMAND
Description The waiting time until the SecurityModeComplete message is
received after the eNB sends the SecurityModeCommand
message to the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value used for the security process between the
Base Station and a device. The connected call is disconnected
when the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-532 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RRC_UE_CAPABILITY_ENQUIRY
Parameter name RRC_UE_CAPABILITY_ENQUIRY
Description The waiting time until the UeCapabilityInformation message is
received after the eNB sends the UeCapabilityEnquiry message to
the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value used for the process of obtaining a device’s
capability information. The connected call is disconnected when
the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-533


CHAPTER 2. Parameter Description

RRC_UE_INFORMATION_REQUEST
Parameter name RRC_UE_INFORMATION_REQUEST
Description The waiting time until the InformationResponse message is
received after the eNB sends the InformationRequest message to
the UE.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 300
Rec. Value 300
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value used for obtaining device information.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-534 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RSRP_FILTER_COEFFICIENT
Parameter name RSRP_FILTER_COEFFICIENT
Description The measurement filtering coefficient for EUTRA RSRP.
Object class & hierarchy PLDQuantityConfigEutra
Type Static
Data Type word16
Unit NA
Range ci_fc0/ci_fc1/ci_fc2/ci_fc3/ci_fc4/ci_fc5/ci_fc6/ci_fc7/ci_fc8/ci_fc9/
ci_fc11/ci_fc13/ci_fc15/ci_fc17/ci_fc19
Read/Write Read/Write
Default value ci_fc4
Rec. Value ci_fc4
Commands RTRV-QUANT-EUTRA/CHG-QUANT-EUTRA
Engineering rules This parameter specifies the measurement filtering coefficient for
RSRP. Value fc0 corresponds to k = 0, fc1 corresponds to k = 1,
and so on.
ci_fc0 = 0,
ci_fc1 = 1,
ci_fc2 = 2,
ci_fc3 = 3,
ci_fc4 = 4,
ci_fc5 = 5,
ci_fc6 = 6,
ci_fc7 = 7,
ci_fc8 = 8,
ci_fc9 = 9,
ci_fc11 = 10,
ci_fc13 = 11,
ci_fc15 = 12,
ci_fc17 = 13,
ci_fc19 = 14.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-535


CHAPTER 2. Parameter Description

RSRQ_FILTER_COEFFICIENT
Parameter name RSRQ_FILTER_COEFFICIENT
Description The measurement filtering coefficient for EUTRA RSRQ.
Object class & hierarchy PLDQuantityConfigEutra
Type Static
Data Type word16
Unit NA
Range ci_fc0/ci_fc1/ci_fc2/ci_fc3/ci_fc4/ci_fc5/ci_fc6/ci_fc7/ci_fc8/ci_fc9/
ci_fc11/ci_fc13/ci_fc15/ci_fc17/ci_fc19
Read/Write Read/Write
Default value ci_fc9
Rec. Value ci_fc9
Commands RTRV-QUANT-EUTRA/CHG-QUANT-EUTRA
Engineering rules This parameter specifies the measurement filtering coefficient for
RSRQ. Value fc0 corresponds to k = 0, fc1 corresponds to k = 1,
and so on.
ci_fc0 = 0,
ci_fc1 = 1,
ci_fc2 = 2,
ci_fc3 = 3,
ci_fc4 = 4,
ci_fc5 = 5,
ci_fc6 = 6,
ci_fc7 = 7,
ci_fc8 = 8,
ci_fc9 = 9,
ci_fc11 = 10,
ci_fc13 = 11,
ci_fc15 = 12,
ci_fc17 = 13,
ci_fc19 = 14.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-536 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RTO_INITIAL
Parameter name RTO_INITIAL
Description The value used to calculate the SCTP round trip time (RTT).
It is the initial value of the Retransmission TimeOut which is used
before the RTT value is measured through packet transmission.
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit msec
Range 100-60000
Read/Write Read/Write
Default value 1000
Rec. Value 1000
Commands RTRV-SCTP-PARA/CHG-SCTP-PARA
Engineering rules This is the parameter for calculating the initial value of the SCTP
Link’s Round Trip Time (RTT). The transmission interval of the
HeartBeat is set based on the RTT value and the
HeartBeatInterval. The RTT value prior to the calculation of the
actual RTT value in the SCTP Link is set to rtoInitial setting.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-537


CHAPTER 2. Parameter Description

RTO_MAX
Parameter name RTO_MAX
Description The maximum value of the Retransmission TimeOut used to
calculate the SCTP round trip time (RTT).
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit msec
Range 100-60000
Read/Write Read/Write
Default value 1400
Rec. Value 1400
Commands RTRV-SCTP-PARA/CHG-SCTP-PARA
Engineering rules This is the maximum value of the SCTP Link’s Round Trip Time
(RTT). The transmission interval of the Heart Beat is set based on
the RTT value and the HeartBeatInterval. The RTT value prior to
the calculation of the actual RTT value in the SCTP Link is set to a
value less than rtoMax setting.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-538 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

RTO_MIN
Parameter name RTO_MIN
Description The minimum value of the Retransmission TimeOut used to
calculate the SCTP round trip time (RTT).
Object class & hierarchy PLDSctpParam
Type Static
Data Type word32
Unit msec
Range 100-60000
Read/Write Read/Write
Default value 1000
Rec. Value 1000
Commands RTRV-SCTP-PARA/CHG-SCTP-PARA
Engineering rules This is the minimum value of the SCTP Link’s Round Trip Time
(RTT). The transmission interval of the Heart Beat is set based on
the RTT value and the HeartBeatInterval. The RTT value prior to
the calculation of the actual RTT value in the SCTP Link is set to a
value greater than rtoMin setting.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-539


CHAPTER 2. Parameter Description

2.19 S
S1_HANDOVER_CANCEL
Parameter name S1_HANDOVER_CANCEL
Description The waiting time to receive the HandoverCancelAcknowledge
message after the eNB sends the HandoverCancel message to the
MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value for receiving the Handover Cancel
Acknowledge message after transmitting the Handover Cancel
message to MME from the Source eNB during the S1 Handover.
Caution/Note Precautions must be taken when changing this value since it is an
optimized setting.
Delta NA
Real time change Yes
Need to reset No

2-540 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S1_HANDOVER_PREPARATION
Parameter name S1_HANDOVER_PREPARATION
Description The waiting time to receive the HandoverCommand message after
the eNB sends the HandoverRequired message to the MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value for the S1 Handover Preparation process. It
is the timer for receiving the Handover Command message after
transmitting the Handover Required message to MME from the
Source eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-541


CHAPTER 2. Parameter Description

S1_INITIAL_CONTEXT_SETUP
Parameter name S1_INITIAL_CONTEXT_SETUP
Description The waiting time to receive the InitialContextSetupRequest
message after the eNB sends the InitilUE message to the MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 10000
Rec. Value 10000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value for receiving the Initial Context Setup
Request message after transmitting the Initial UE to MME.
A call where the connection is in progress is dropped when the
timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-542 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S1_PATH_SWITCH
Parameter name S1_PATH_SWITCH
Description The waiting time to receive the PathSwitchRequestAcknowledge
message after the eNB sends the PathSwitchReques message to
the MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 3000
Rec. Value 3000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This parameter is used for the Path Switch by the Target eNB
during S1 Handover. A call where the Handover process is
progress is disconnected when the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-543


CHAPTER 2. Parameter Description

S1_RELOC_OVERALL
Parameter name S1_RELOC_OVERALL
Description The waiting time to receive the UEContextReleaseCommand
message from the MME when handover is completed after the
MME receives the HandoverCommand message from the eNB.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value for the receiving the UE Context Release
Command message after transmitting the RRC Connection
Reconfiguration message to MME from the Source eNB during S1
Handover process. The call which the Handover process is in
progress is disconnected when the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-544 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S1_SETUP
Parameter name S1_SETUP
Description The waiting time to receive the S1SetupResponse or
S1SetupFailure message after the eNB sends the
S1SetupRequest message to the MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules A Base Station engages in S1 Setup process with the MME when
the SCTP connection is made after the installation of the Base
Station. This timer is for receiving the S1 Setup Response
message from the MME. If the timer expires without having
received the S1 Setup Response message, the S1 Setup process
is repeated.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-545


CHAPTER 2. Parameter Description

S1_UE_CONTEXT_RELEASE
Parameter name S1_UE_CONTEXT_RELEASE
Description The waiting time to receive the UEContextReleaseCommand
message after the eNB sends the UEContextReleaseRequest
message to the MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules A Base Station sends the UE Context Release Request message
to the MME when the Base Station seeks to drop a call.
This timer is for receiving the UE Context Release Request
message from the MME after sending the UE Context Release
Request message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-546 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S1_UPDATE
Parameter name S1_UPDATE
Description The waiting time to receive the
EnbConfigurationUpdateAcknowledge or
EnbConfigurationUpdateFailure message after the eNB sends the
EnbConfigurationUpdate message to the MME.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for the S1 ENB Configuration Update process.
A Base Station repeats the process based on the number set in the
S1_UPDATE_RETRY_COUNT in case of an update failure.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-547


CHAPTER 2. Parameter Description

S1_UPDATE_RETRY_COUNT
Parameter name S1_UPDATE_RETRY_COUNT
Description The retry count to perform the eNB configuration update procedure
when the eNBConfigurationUpdateFailure message is received from
the MME or timeout occurs after the eNB sends the
eNBConfigurationUpdate message.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit count
Range ci_CountZero/ci_CountOne/ci_CountTwo/ci_CountThree/
ci_CountTen/ci_CountInfinity
Read/Write Read/Write
Default value ci_CountThree
Rec. Value ci_CountThree
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This parameter indicates the retry count in case of S1 ENB
Configuration Update failure.
- ci_CountZero: no retry is attempted.
- ci_CountOne: retry is attempted 1 time.
- ci_CountTwo: retry is attempted 2 times.
- ci_CountThree: retry is attempted 3 times.
- ci_CountTen: retry is attempted 10 times.
- ci_CountInfinity: retry is attempted infinitely.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-548 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S1_UPDATE_TIME_TO_WAIT
Parameter name S1_UPDATE_TIME_TO_WAIT
Description The TimetoWait value included upon sending the
MMEConfigurationUpdateFailure
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit sec
Range ci_v1s/ci_v2s/ci_v5s/ci_v10s/ci_v20s/ci_v60s
Read/Write Read/Write
Default value ci_v5s
Rec. Value ci_v5s
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value that must be included in the message when
transmitting the MME Configuration Update Failure message, due
to a Base Station problem, after receiving MME Configuration
Update message.
- ci_v1s: 1 sec.
- ci_v2s: 2 sec.
- ci_v5s: 3 sec.
- ci_v10s: 10 sec.
- ci_v20s: 20 sec.
- ci_v60s: 60 sec.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-549


CHAPTER 2. Parameter Description

SCHEDULING_TYPE
Parameter name SCHEDULING_TYPE
Description The scheduling type of the QoS class identifier (QCI).
The entered parameter value is used for scheduling in the MAC
layer.
- Dynamic_scheduling: The QCI uses the dynamic scheduling.
- SPS_scheduling: The QCI uses the SPS scheduling.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range Dynamic_scheduling/SPS_scheduling
Read/Write Read/Write
Default value Dynamic_scheduling
Rec. Value Dynamic_scheduling
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-550 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SCTP_PORT_NUM_S1
Parameter name SCTP_PORT_NUM_S1
Description The port number to be used to configure the SCTP association
with the MME for S1AP
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type word32
Unit NA
Range 0-65535
Read/Write Read Only
Default value 36412
Rec. Value 36412
Commands RTRV-ENB-INF
Engineering rules The port number is fixed to 36412. The SCTP association is
possible only when the port value is specified to be the same as
the SCTP of MME.
Caution/Note NA
Delta NA
Real time change It is operated with a fixed value, and the value cannot be changed
while in operation.
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-551


CHAPTER 2. Parameter Description

SCTP_PORT_NUM_X2
Parameter name SCTP_PORT_NUM_X2
Description The port number to be used to configure the SCTP association
with a neighbor eNB for X2AP
Object class & hierarchy PLDEnbInfoPhy
Type Static
Data Type word32
Unit NA
Range 0-65535
Read/Write Read Only
Default value 36422
Rec. Value 36422
Commands RTRV-ENB-INF
Engineering rules The port number is fixed to 36422.
The SCTP association is possible only when the port value is
specified to be the same as the SCTP of the neighbor eNB.
Caution/Note NA
Delta NA
Real time change This value is fixed value, and cannot be changed during operation.
Need to reset No

SEARCH_RATE
Parameter name SEARCH_RATE
Description Rate of selecting frequency as highest priority
Object class & hierarchy PLDIdleModeLbInfoFunc
Type Static
Data Type word32
Unit NA
Range 0-65535
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-IDLELB-INFO/CHG-IDLELB-INFO
Engineering rules This parameter indicates the FA selection ratio during Idle Mode
Load Distribution. The Idle Mode Load Distribution for each FA is
engaged based on this setting.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-552 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SECONDARY_MME_IPV4
Parameter name SECONDARY_MME_IPV4
Description The secondary IP address value of the IPv4 type which is set to
the MME node to support the SCTP multi-homing function.
It is valid when the IP_VER value is IPv4.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type IPv4Address
Unit NA
Range 0-255
Read/Write Read/Write
Default value ‘0.0.0.0’
Rec. Value ‘0.0.0.0’
Commands RTRV-MME-CONF/CHG-MME-CONF
Engineering rules It is the IPV4 Address for the SCTP Multi-Homing feature.
The value is only valid when using the Multi-Homing feature.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-553


CHAPTER 2. Parameter Description

SECONDARY_MME_IPV6
Parameter name SECONDARY_MME_IPV6
Description The secondary IP address value of the IPv6 type which is set to
the MME node to support the SCTP multi-homing function.
It is valid when the IP_VER value is IPv6.
Object class & hierarchy PLDProxyMMEConf
Type Static
Data Type IPv6Address
Unit NA
Range 0-255
Read/Write Read/Write
Default value ‘0:0:0:0:0:0:0:0’
Rec. Value ‘0:0:0:0:0:0:0:0’
Commands RTRV-MME-CONF/CHG-MME-CONF
Engineering rules It is the IPV6 Address for the SCTP Multi-Homing feature.
The value is only valid when using the Multi-Homing feature.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

secondaryNbrEnbIPv4
Parameter name secondaryNbrEnbIPv4
Description Enter the neighbor eNB secondary IP information in the form of IP
Version4.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type IPv4Address
Unit NA
Range 0-255
Read/Write Read/Write
Default value ‘0.0.0.0’
Rec. Value ‘0.0.0.0’
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the secondary Ipv4 Address of the
Neighbor ENB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-554 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

secondaryNbrEnbIPv6[16]
Parameter name secondaryNbrEnbIPv6[16]
Description Enter the neighbor eNB secondary IP information in the form of IP
Version6.
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type IPv6Address
Unit NA
Range 0-255
Read/Write Read/Write
Default value ‘0:0:0:0:0:0:0:0’
Rec. Value ‘0:0:0:0:0:0:0:0’
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the secondary Ipv6 Address of the
Neighbor ENB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

SERVER_NUM
Parameter name SERVER_NUM
Description The number of a server to change/retrieve.
Object class & hierarchy PLDServerCacInfo
Type Static
Data Type word32
Unit NA
Range 0-3
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-SVR-CAC/CHG-SVR-CAC
Engineering rules This is the Number of the Cell to which the server belongs to.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-555


CHAPTER 2. Parameter Description

SERVICE_GROUP
Parameter name SERVICE_GROUP
Description The service group
- voipService: The service group which uses the voice over Internet
protocol (VOIP) service.
- videoService: The service group which uses the video service.
Object class & hierarchy PLDSvcGrpBhBwInfo
Type Static
Data Type word32
Unit NA
Range voipService/videoService
Read/Write Read/Write
Default value voipService
Rec. Value voipService
Commands RTRV-BHBW-SVCGR/CHG-BHBW-SVCGR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-556 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SF_USAGE
Parameter name SF_USAGE
Description Indicates whether to use the scaling factor.
- CI_no_use: T_RESELECTION_SF_MEDIUM and
T_RESELECTION_SF_HIGH value are not used.
- CI_use: T_RESELECTION_SF_MEDIUM and
T_RESELECTION_SF_HIGH value are used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type enum
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter determines whether or not the scaling factor is
used by the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-557


CHAPTER 2. Parameter Description

SF_USAGE
Parameter name SF_USAGE
Description Indicates whether to use the scaling factor related to the GERAN
reselection in the eNB.
- CI_no_use: Scaling factor is not used.
- CI_use: Scaling factor is used.
Object class & hierarchy PLDGeranReselectInfoLogic
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-GERAN-RESEL/CHG-GERAN-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-558 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SF_USAGE
Parameter name SF_USAGE
Description Indicates whether to use the scaling factor.
- CI_no_use: Scaling factor is not used.
- CI_use: Scaling factor is used.
Object class & hierarchy PLDMeasurementInfoFunc
Type Static
Data Type enum
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-MEAS-FUNC/CHG-MEAS-FUNC
Engineering rules This parameter determines whether the scaling factor is used or not.
If the parameter is set to CI_no_use, then the scaling factor
information is not included when configuring the measurement
configuration (i.e., RRC Connection Reconfiguration). If it is set to
CI_use, then the scaling factor is included.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-559


CHAPTER 2. Parameter Description

SF_USAGE
Parameter name SF_USAGE
Description Indicates whether to use the scaling factor related to the UTRAN
FA reselection.
- CI_no_use: Scaling factor is not used.
- CI_use: Scaling factor is used.
Object class & hierarchy PLDUtraReselectInfoLogic
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-UTRA-RESEL/CHG-UTRA-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-560 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SIB10_PERIOD
Parameter name SIB10_PERIOD
Description The transmission period for the system information block type 10 of
the cell in the eNB.
- ci_rf80: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB10 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf512
Rec. Value ci_rf512
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-561


CHAPTER 2. Parameter Description

SIB11_PERIOD
Parameter name SIB11_PERIOD
Description The transmission period for the system information block type 11 of
the cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB11 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf512
Rec. Value ci_rf512
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-562 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SIB12_PERIOD
Parameter name SIB12_PERIOD
Description The transmission period for the system information block type 12 of
the cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB12 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf512
Rec. Value ci_rf512
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-563


CHAPTER 2. Parameter Description

SIB2_PERIOD
Parameter name SIB2_PERIOD
Description The transmission period for the system information block type 2 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB2 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf16
Rec. Value ci_rf16
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-564 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SIB3_PERIOD
Parameter name SIB3_PERIOD
Description The transmission period for the system information block type 3 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB3 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf32
Rec. Value ci_rf32
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-565


CHAPTER 2. Parameter Description

SIB4_PERIOD
Parameter name SIB4_PERIOD
Description The transmission period for the system information block type 4 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB4 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf64
Rec. Value ci_rf64
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-566 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SIB5_PERIOD
Parameter name SIB5_PERIOD
Description The transmission period for the system information block type 5 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB5 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf128
Rec. Value ci_rf128
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-567


CHAPTER 2. Parameter Description

SIB6_PERIOD
Parameter name SIB6_PERIOD
Description The transmission period for the system information block type 6 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB6 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_not_used
Rec. Value ci_not_used
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-568 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SIB7_PERIOD
Parameter name SIB7_PERIOD
Description The transmission period for the system information block type 7 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB7 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_not_used
Rec. Value ci_not_used
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-569


CHAPTER 2. Parameter Description

SIB8_PERIOD
Parameter name SIB8_PERIOD
Description The transmission period for the system information block type 8 of the
cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB8 is not transmitted.
Object class & PLDSibSchedulingInfoLogic
hierarchy
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_not_used
Rec. Value ci_not_used
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-570 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SIB9_PERIOD
Parameter name SIB9_PERIOD
Description The transmission period for the system information block type 9 of
the cell in the eNB.
- ci_rf8: 80 ms.
- ci_rf16: 160 ms.
- ci_rf32: 320 ms.
- ci_rf64: 640 ms.
- ci_rf128: 1280 ms.
- ci_rf256: 2560 ms.
- ci_rf512: 5120 ms.
- ci_not_used: SIB9 is not transmitted.
Object class & hierarchy PLDSibSchedulingInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_rf8/ci_rf16/ci_rf32/ci_rf64/ci_rf128/ci_rf256/ci_rf512/ci_not_used
Read/Write Read/Write
Default value ci_rf32
Rec. Value ci_rf32
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-571


CHAPTER 2. Parameter Description

S_INTRA_SEARCH
Parameter name S_INTRA_SEARCH
Description The threshold value for intra-frequency measurement.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The sIntraSearch is used to indicate an Rx level threshold for intra-
frequency cell re-selection. Actual value of threshold = IE value * 2
[dB].
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

S_INTRA_SEARCH_P
Parameter name S_INTRA_SEARCH_P
Description The threshold-P value for the intra-frequency measurement of Rel-9
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Srxlev threshold (in dB) for intra-frequency
measurements.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-572 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S_INTRA_SEARCH_Q
Parameter name S_INTRA_SEARCH_Q
Description The threshold-Q value for the intra-frequency measurement of Rel-9
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
This specifies the Squal threshold (in dB) for intra-frequency
Engineering rules
measurements.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

S_INTRA_SEARCH_REL9_USAGE
Parameter name S_INTRA_SEARCH_REL9_USAGE
Description Indicates whether to use the sIntraSearch for Rel-9.
- CI_no_use: sIntraSearch is not used.
- CI_use: sIntraSearch is used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is for setting whether or not the sIntraSearchRel9 is
used by the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-573


CHAPTER 2. Parameter Description

S_INTRA_SEARCH_USAGE
Parameter name S_INTRA_SEARCH_USAGE
Description Indicates whether to use sIntraSearch.
- CI_no_use: sIntraSearch is not used.
- CI_use: sIntraSearch is used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type enum
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_use
Rec. Value CI_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is for setting whether or not the sIntraSearch is
used by the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-574 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SI_WINDOW
Parameter name SI_WINDOW
Description The system Information window size of a cell in the eNB
Each SI message is associated with one SI-window, and does not
overlaps with the SI-windows of other SI messages. That is, one SI
is sent to one SI window. The length of SI-window is the same for
all SI messages.
The corresponding SI message in the SI-window is sent repeatedly.
Its range is as follow:
- ci_si_WindowLength_ms1: 1 ms.
- ci_si_WindowLength_ms2: 2 ms.
- ci_si_WindowLength_ms5: 5 ms.
- ci_si_WindowLength_ms10: 10 ms.
- ci_si_WindowLength_ms15: 15 ms.
- ci_si_WindowLength_ms20: 20 ms.
- ci_si_WindowLength_ms40: 40 ms.
Object class & hierarchy PLDSibSchedulingInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_si_WindowLength_ms1/ci_si_WindowLength_ms2/
ci_si_WindowLength_ms5/ci_si_WindowLength_ms10/
ci_si_WindowLength_ms15/ci_si_WindowLength_ms20/
ci_si_WindowLength_ms40
Read/Write Read/Write
Default value ci_si_WindowLength_ms20
Rec. Value ci_si_WindowLength_ms20
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-575


CHAPTER 2. Parameter Description

S_MEASURE
Parameter name S_MEASURE
Description The quality threshold of a serving cell by which the UE controls the
measurement of the intra-frequency, inter-frequency and inter-RAT
neighbor cell.
Object class & hierarchy PLDMeasurementInfoFunc
Type Static
Data Type int
Unit dBm
Range 0-97
Read/Write Read/Write
Default value 61
Rec. Value 61
Commands RTRV-MEAS-FUNC/CHG-MEAS-FUNC
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active).
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-576 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SNN
Parameter name SNN
Description Indicates whether to use the GTP sequence number.
- 0: eNB does not use the GTP sequence number.
- 1: eNB uses the GTP sequence number.
Object class & hierarchy PLDGtpInfoFunc
Type Static
Data Type byte
Unit NA
Range 0-1
Read/Write Read/Write
Default value 1
Rec. Value 1
Commands RTRV-GTP-INF/CHG-GTP-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-577


CHAPTER 2. Parameter Description

S_NON_INTRA_SEARCH
Parameter name S_NON_INTRA_SEARCH
Description The threshold value for the inter-RAT and inter-frequency
measurement
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The sNonIntraSearch is used to indicate an Rx level threshold for
inter-frequency cell re-selection. Actual value of threshold = IE
value * 2 [dB].
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

S_NON_INTRA_SEARCH_P
Parameter name S_NON_INTRA_SEARCH_P
Description The threshold-P value for the inter-RAT and inter-frequency
measurement
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Srxlev threshold (in dB) for E-UTRAN inter-
frequency and inter-RAT measurements.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-578 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

S_NON_INTRA_SEARCH_Q
Parameter name S_NON_INTRA_SEARCH_Q
Description The threshold-Q value for the inter-RAT and inter-frequency
measurement
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Squal threshold (in dB) for E-UTRAN inter-
frequency and inter-RAT measurements.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

S_NON_INTRA_SEARCH_REL9_USAGE
Parameter name S_NON_INTRA_SEARCH_REL9_USAGE
Description Indicates whether to use the sNonIntraSearch for Rel-9.
- CI_no_use: sNonIntraSearch is not used.
- CI_use: sNonIntraSearch is used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting whether or not
sNonIntraSearchRel9 is used by the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-579


CHAPTER 2. Parameter Description

S_NON_INTRA_SEARCH_USAGE
Parameter name S_NON_INTRA_SEARCH_USAGE
Description Indicates whether to use sNonIntraSearch.
- CI_no_use: sNonIntraSearch is not used.
- CI_use: sNonIntraSearch is used.
Object class &hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_use
Rec. Value CI_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting whether or not sNonIntraSearch
is used by the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-580 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SPEED_STATE_RE_SEL_PARS_USAGE
Parameter name SPEED_STATE_RE_SEL_PARS_USAGE
Description Indicates whether to use the speedStateReselectonPars field of the
cell in eNB.
- CI_no_use: speedStateReselectonPars field is not used.
- CI_use: speedStateReselectonPars field is used.
Object class & hierarchy PLDMobilityStateInfoLogic
Type Static
Data Type word32
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-MOBIL-STA/CHG-MOBIL-STA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-581


CHAPTER 2. Parameter Description

SPID
Parameter name SPID
Description Subscriber profile ID for RAT/frequency priority value.
- spid_254: The subscriber profile ID of the UE is 254.
- spid_255: The subscriber profile ID of the UE is 255.
- spid_256: The subscriber profile ID of the UE is 256.
Object class & hierarchy PLDEutranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range spid_254/spid_255/spid_256
Read/Write READ only
Default value spid_254
Rec. Value spid_254
Commands RTRV-EUTRA-PRIOR/CHG-EUTRA-PRIOR
Engineering rules This is a device’s SPID for setting the Idle Mode’s FA Priority.
It is an Index value so it cannot be changed.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-582 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SPID
Parameter name SPID
Description Subscriber profile ID for RAT/frequency priority value.
Object class & hierarchy PLDGeranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range spid_254/spid_255/spid_256
Read/Write Read/Write
Default value spid_254
Rec. Value spid_254
Commands RTRV-GERAN-PRIOR/CHG-GERAN-PRIOR
Engineering rules Subscriber profile ID for RAT/frequency priority value.
- spid_254 = 0
- spid_255 = 1
- spid_256 = 2
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-583


CHAPTER 2. Parameter Description

SPID
Parameter name SPID
Description Subscriber profile ID for RAT/frequency priority value.
Object class & hierarchy PLDUtranDedicatedPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range spid_254 /spid_255/spid_256
Read/Write Read Only
Default value spid_254
Rec. Value spid_254
Commands RTRV-UTRA-PRIOR/CHG-UTRA-PRIOR
Engineering rules This is a device’s SPID for setting the Idle Mode’s FA Priority.
It is an Index value so it cannot be changed.
- spid_254 = 0
- spid_255 = 1
- spid_256 = 2
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-584 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

START_PCI
Parameter name START_PCI
Description The starting physical cell ID value of a black list cell
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word16
Unit NA
Range 0-503
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-BLACK-LIST/CHG-BLACK-LIST/CRTE-BLACK-LIST/
DLT-BLACK-LIST
Engineering rules This parameter is used for setting the start value of the blacklist
Cell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-585


CHAPTER 2. Parameter Description

STATUS
Parameter name STATUS
Description Indicates whether the tuple information is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDBlackListedCellInfoLogic
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-BLACK-LIST/CHG-BLACK-LIST/CRTE-BLACK-LIST/
DLT-BLACK-LIST
Engineering rules This parameter determines the usage of each blacklist Cell.
If the setting is N_EQUIP, the corresponding blacklist Cell is not
used. If the setting is EQUIP, then the corresponding blacklist Cell
is used. In other words, only blacklist Cells in an EQUIP state are
transmitted to a device.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-586 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

STATUS
Parameter name STATUS
Description Indicates whether the EUTRA FA is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is used for setting whether or not to use the
corresponding E-UTRA Frequency. If the setting is N_EQUIP, the
corresponding E-UTRA Frequency is not used. If the setting is
EQUIP, then the corresponding E-UTRA Frequency is used.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-587


CHAPTER 2. Parameter Description

STATUS
Parameter name STATUS
Description Indicates whether the neighbor eNB information is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDExternalEnbConf
Type Dynamic
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-NBR-ENB/CHG-NBR-ENB/CRTE-NBR-ENB/DLT-NBR-ENB
Engineering rules This parameter indicates the validity of the Neighbor ENB.
If the setting is N_EQUIP, the information is determined as invalid.
If the setting is EQUIP, then the information is determined as valid.
Caution/Note This parameter must be set accurately since it determines the X2
Link and Handover execution.
Delta NA
Real time change Yes
Need to reset No

2-588 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

STATUS
Parameter name STATUS
Description Indicates whether the information on the E-UTRAN neighbor cell
located near the eNB is valid.
- N_EQUIP: E-UTRAN neighbor cell information is not valid.
- EQUIP: E-UTRAN neighbor cell information is valid.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the validity of the Neighbor EUTRAN.
If the setting is N_EQUIP, the information is determined as invalid.
If the setting is EQUIP, then the information is determined as valid.
Caution/Note This parameter must be set accurately since it determines the
Handover execution.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-589


CHAPTER 2. Parameter Description

STATUS
Parameter name STATUS
Description Indicates whether the information on the GERAN neighbor cell
located near the eNB is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates the validity of the Neighbor GERAN.
If the setting is N_EQUIP, the information is determined as invalid.
If the setting is EQUIP, then the information is determined as valid.
Caution/Note This parameter must be set accurately since it determines the RIM
operation and Handover execution.
Delta NA
Real time change Yes
Need to reset No

2-590 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

STATUS
Parameter name STATUS
Description Indicates whether the information on the UTRAN neighbor cell
located near the eNB is valid.
- N_EQUIP: UTRAN neighbor cell information is not valid.
- EQUIP: UTRAN neighbor cell information is valid.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates the validity of the Neighbor UTRAN.
If the setting is N_EQUIP, the information is determined as invalid.
If the setting is EQUIP, then the information is determined as valid.
Caution/Note This parameter must be set accurately since it determines the RIM
operation and Handover execution.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-591


CHAPTER 2. Parameter Description

STATUS
Parameter name STATUS
Description Indicates whether the GERAN FA object is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-592 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

STATUS
Parameter name STATUS
Description Indicates whether each tuple information is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDIdleModeLbInfoFunc
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-IDLELB-INFO/CHG-IDLELB-INFO
Engineering rules This parameter indicates the validity of the FA information used for
Idle Mode Load Distribution. If the setting is N_EQUIP, the
information is determined as invalid. If the setting is EQUIP, then
the information is determined as valid.
Caution/Note This parameter must be set accurately since it determines the Idle
Mode Load Distribution.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-593


CHAPTER 2. Parameter Description

STATUS
Parameter name STATUS
Description EQUIP status information of the MME

Object class & hierarchy PLDProxyMMEConf


Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-MME-CONF/CHG-MME-CONF
Engineering rules - N_EQUIP: Connection target MME does not exist (default).
- EQUIP: Connection target MME exists.
Caution/Note Perform S1 Setup procedure with MME when EQUIP.
Please note that in case of N_EQUIP, the connection between the
MME and S1, for which the S1 Setup is already completed, is lost,
and call service becomes disabled.
Delta NA
Real time change Yes
Need to reset No

2-594 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

STATUS
Parameter name STATUS
Description Indicates whether the QoS class identifier (QCI) is used.
- EQUIP: eNB uses the QCI.
- N_EQUIP: eNB does not use the QCI.
Object class & hierarchy PLDQciValueInfoFunc
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-QCI-VAL/CHG-QCI-VAL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-595


CHAPTER 2. Parameter Description

STATUS
Parameter name STATUS
Description The RIM status change information
Object class & hierarchy PLDRimControl
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-RIM-CONTROL/CHG-RIM-CONTROL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

STATUS
Parameter name STATUS
Description Indicates whether the EUTRA FA is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-596 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

STATUS
Parameter name STATUS
Description Indicates whether the EUTRA FA is valid.
- N_EQUIP: not valid
- EQUIP: valid
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

STATUS
Parameter name STATUS
Description Relation Status Information
Object class & hierarchy PLDUtranSubcellRelation
Type Static
Data Type word32
Unit NA
Range N_EQUIP/EQUIP
Read/Write Read/Write
Default value N_EQUIP
Rec. Value N_EQUIP
Commands CHG-UTRA-SCELLREL/RTRV-UTRA-SCELLREL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-597


CHAPTER 2. Parameter Description

STATUS_REPORT_REQUIRED
Parameter name STATUS_REPORT_REQUIRED
Description Setting value which determines whether to transmit the SN status
report.
Object class & hierarchy PLDPdcpInfoFunc
Type Static
Data Type word32
Unit NA
Range False/True
Read/Write Read/Write
Default value True
Rec. Value True
Commands RTRV-PDCP-INF/CHG-PDCP-INF
Engineering rules This is the setting that determines whether or not to transmit the
SN status report.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

SUB_CELL_NUM
Parameter name SUB_CELL_NUM
Description Sub cell number
Object class & hierarchy PLDInterworkPara
Type Static
Data Type word32
Unit NA
Range 0-MAX_SUBCELL_PER_SYS_CDD
Read/Write Read Only
Default value 0
Rec. Value 0
Commands RTRV-INTER-PARA/CHG-INTER-PARA
Engineering rules This parameter indicates the SubCell Number to which the Relation
information is applied.
Caution/Note NA
Delta NA
Real time change The Index value cannot be changed.
Need to reset No

2-598 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

SUB_CELL_NUM
Parameter name SUB_CELL_NUM
Description SubcellNum index.
Object class & hierarchy PLDSubCellInfo
Type Static
Data Type word32
Unit NA
Range 0-17
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-SCELL-CONF/CHG-SCELL-CONF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

SUB_CELL_NUM
Parameter name SUB_CELL_NUM
Description The subCell number. Input range is up to the maximum value of the
subCell supported by the system, which is determined per the
FA/Sector. For example, if the maximum capacity of each system
provided to the operator is 1FA/3Sector, maximum 3 subCells are
supported.
Object class & hierarchy PLDSubCellUeCnt
Type Static
Data Type word32
Unit NA
Range 0-MAX_SUBCELL_PER_SYS_CDD
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-SCELL-UECNT/CHG-SCELL-UECNT
Engineering rules This is the parameter that indicates the Subcell number. It is used
as a key for viewing the accumulated UE count for each Subcell.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-599


CHAPTER 2. Parameter Description

SUB_CELL_NUM
Parameter name SUB_CELL_NUM
Description Subcell Number
Object class & hierarchy PLDUtranSubcellRelation
Type Static
Data Type word32
Unit NA
Range 0-MAX_SUBCELL_PER_SYS_CDD
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-SCELLREL/CHG-UTRA-SCELLREL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-600 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.20 T
T300
Parameter name T300
Description The timer t300 value of the cell in eNB. The UE starts the t300 timer
after sending the RRC connection request; and ends the timer when
the RRC Connection Setup message or RRC Connection Reject
message is received. When the t300 timer is ended, the UE resets
the MAC, releases the MAC configuration, and reestablishes the
RLC.
Its initial value is 200 ms, which can be changed by the operator
during operation.
- ci_t_300_ms100: 100 ms.
- ci_t_300_ms200: 200 ms.
- ci_t_300_ms300: 300 ms.
- ci_t_300_ms400: 400 ms.
- ci_t_300_ms600: 600 ms.
- ci_t_300_ms1000: 1000 ms.
- ci_t_300_ms1500: 1500 ms.
- ci_t_300_ms2000: 2000 ms.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_300_ms100/ci_t_300_ms200/ci_t_300_ms300/ci_t_300_ms400/
ci_t_300_ms600/ci_t_300_ms1000/ci_t_300_ms1500/
ci_t_300_m2000
Read/Write Read/Write
Default value ci_t_300_ms200
Rec. Value ci_t_300_ms200
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-601


CHAPTER 2. Parameter Description

T301
Parameter name T301
Description The timer t301 value of the cell in eNB. The UE starts the t301 timer
after sending the RRC Connection Reestablishment Request; and
ends the timer when the RRC Connection Reestablishment message
or RRC Connection Reestablishment Reject message is received.
When the t301 timer is ended, the UE becomes idle. Its initial value
is 200 ms, which can be changed by the operator during operation.
- ci_t_301_ms100: 100 ms.
- ci_t_301_ms200: 200 ms.
- ci_t_301_ms300: 300 ms.
- ci_t_301_ms400: 400 ms.
- ci_t_301_ms600: 600 ms.
- ci_t_301_ms1000: 1000 ms.
- ci_t_301_ms1500: 1500 ms.
- ci_t_301_ms2000: 2000 ms.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_301_ms100/ci_t_301_ms200/ci_t_301_ms300/ci_t_301_ms400/
ci_t_301_ms600/ci_t_301_ms1000/ci_t_301_ms1500/
ci_t_301_m2000
Read/Write Read/Write
Default value ci_t_301_ms200
Rec. Value ci_t_301_ms200
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-602 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T302
Parameter name T302
Description The timer value which the UE starts after receiving the RRC
Connection Reject message. It is released when the UE becomes
the RRC_Connect status, or a cell is reselected. If the timer ends,
the UE regards it as a cell barred status, and reselects a cell.
Its initial value is 8 seconds, which can be changed by the operator
during operation.
- ci_t_302_s1: 1 second.
- ci_t_302_s2: 2 seconds.
- ci_t_302_s3: 3 seconds.
- ci_t_302_s4: 4 seconds.
- ci_t_302_s5: 5 seconds.
- ci_t_302_s6: 6 seconds.
- ci_t_302_s7: 7 seconds.
- ci_t_302_s8: 8 seconds.
- ci_t_302_s9: 9 seconds.
- ci_t_302_s10: 10 seconds.
- ci_t_302_s11: 11 seconds.
- ci_t_302_s12: 12 seconds.
- ci_t_302_s13: 13 seconds.
- ci_t_302_s14: 14 seconds.
- ci_t_302_s15: 15 seconds.
- ci_t_302_s16: 16 seconds.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_302_s1/ci_t_302_s2/ci_t_302_s3/ci_t_302_s4/ci_t_302_s5/
ci_t_302_s6/ci_t_302_s7/ci_t_302_s8/ci_t_302_s9/ci_t_302_s10/
ci_t_302_s11/ci_t_302_s12/ci_t_302_s13/ci_t_302_s14/
ci_t_302_s15/ci_t_302_s16
Read/Write Read/Write
Default value ci_t_302_s8
Rec. Value ci_t_302_s8
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-603


CHAPTER 2. Parameter Description

T304
Parameter name T304
Description The timer value which, during handover, the UE starts after receiving
the RRC Connection Reconfiguration message.
The timer is released when handover to the EUTRA is performed
normally. Its initial value is 200 ms, which can be changed by the
operator during operation.
- ci_t_304_ms50: 50 ms.
- ci_t_304_ms100: 100 ms.
- ci_t_304_ms150: 150 ms.
- ci_t_304_ms200: 200 ms.
- ci_t_304_ms500: 500 ms.
- ci_t_304_ms1000: 1000 ms.
- ci_t_304_ms2000: 2000 ms.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_304_ms50/ci_t_304_ms100/ci_t_304_ms150/ci_t_304_ms200/
ci_t_304_ms500/ci_t_304_ms1000/ci_t_304_ms2000
Read/Write Read/Write
Default value ci_t_304_ms200
Rec. Value ci_t_304_ms200
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-604 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T310
Parameter name T310
Description The timer value which the UE starts after receiving consecutively
as many out-of-syncIndications as the N310. It is released when as
many out-of-syncIndications as the N311 are received
consecutively, handover is triggered, or the reestablishment
procedure is triggered.
- ci_t_310_ms0: 0 ms.
- ci_t_310_ms50: 50 ms.
- ci_t_310_ms100: 100 ms.
- ci_t_310_ms200: 200 ms.
- ci_t_310_ms500: 500 ms.
- ci_t_310_ms1000: 1000 ms.
- ci_t_310_ms2000: 2000 ms.
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_310_ms0/ci_t_310_ms50/ci_t_310_ms100/ci_t_310_ms200/
ci_t_310_ms500/ci_t_310_ms1000/ci_t_310_ms2000
Read/Write Read/Write
Default value ci_t_310_ms1000
Rec. Value ci_t_310_ms1000
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-605


CHAPTER 2. Parameter Description

T311
Parameter name T311
Description The timer value which the UE starts upon starting the
reestablishment procedure. The timer ends when a suitable EUTRA
cell or inter-RAT cell is found. If the timer ends without finding a
suitable cell, it returns to the RRC_IDLE status. Its initial value is
10000 ms, which can be changed by the operator during operation.
- ci_t_311_ms1000: 1000 ms
- ci_t_311_ms3000: 3000 ms
- ci_t_311_ms5000: 5000 ms
- ci_t_311_ms10000: 10000 ms
- ci_t_311_ms15000: 15000 ms
- ci_t_311_ms20000. 20000 ms
- ci_t_311_ms30000: 30000 ms
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_311_ms1000/ci_t_311_ms3000/ci_t_311_ms5000/
ci_t_311_ms10000/ci_t_311_ms15000/ci_t_311_ms20000/
ci_t_311_ms30000
Read/Write Read/Write
Default value ci_t_311_ms3000
Rec. Value ci_t_311_ms3000
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-606 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T320
Parameter name T320
Description The timer value which the UE starts when receiving the t320 timer
value. Or, it is started when call reselection occurs from other RAT to
the EUTRA; and the timer ends when it becomes the
RRC_CONNECTED status. Its initial value is 30 minutes, which can
be changed by the operator during operation.
- ci_t_320_min5: 5 minutes
- ci_t_320_min10: 10 minutes
- ci_t_320_min20: 20 minutes
- ci_t_320_min30: 30 minutes
- ci_t_320_min60: 60 minutes
- ci_t_320_min120: 120 minutes
- ci_t_320_min180: 180 minutes
Object class & hierarchy PLDUeTimerConstInfoLogic
Type Static
Data Type short
Unit NA
Range ci_t_320_min5/ci_t_320_min10/ci_t_320_min20/ci_t_320_min30/
ci_t_320_min60/ci_t_320_min120/ci_t_320_min180
Read/Write Read/Write
Default value ci_t_320_min30
Rec. Value ci_t_320_min30
Commands RTRV-TIME-INF/CHG-TIME-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-607


CHAPTER 2. Parameter Description

T3_TMR
Parameter name T3_TMR
Description The interval of retransmitting the ECHO-REQ message when the
response message to the ECHO-REQ message transmitted for
Keep Alive is not received. Its range is 0-60000 msec, and initial
value is 5000 (5 seconds). It works only when KEEP_ALIVE is ‘1’.
Object class & hierarchy PLDGtpInfoFunc
Type Static
Data Type int
Unit msec
Range 0-60000
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-GTP-INF/CHG-GTP-INF
Engineering rules The corresponding parameter is the retransmission interval for the
GTP Echo Request.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-608 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T3_TMR_LONG
Parameter name T3_TMR_LONG
Description The interval of sending the ECHO-REQ message for periodic Keep
Alive. Its range is 60000-600000 msec, and initial value is 60000
(60 seconds). It works only when KEEP_ALIVE is ‘1’.
Object class & hierarchy PLDGtpInfoFunc
Type Static
Data Type int
Unit msec
Range 60000-600000
Read/Write Read/Write
Default value 60000
Rec. Value 60000
Commands RTRV-GTP-INF/CHG-GTP-INF
Engineering rules The corresponding parameter is the transmission interval for the
GTP Echo Request. The 3GPP GTP specification recommends the
setting be greater than 60 seconds.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-609


CHAPTER 2. Parameter Description

TAC
Parameter name TAC
Description The tracking area code of the E-UTRAN neighbor cell located near
the eNB.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word16
Unit NA
Range 0x0-0xFFFF
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Tracking Area Code of the Neighbor
EUTRAN Cell. The X2 Handover and S1 Handover are determined
by this information.
Caution/Note The information must be entered accurately because the X2/S1
Handover is determined by this information.
Delta NA
Real time change Yes
Need to reset No

2-610 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TARGET_CELL_NUM
Parameter name TARGET_CELL_NUM
Description The local cell ID of the E-UTRAN neighbor cell located near the
eNB.
Object class & hierarchy PLDExternalEUtranCellFDDLogic
Type Dynamic
Data Type word32
Unit NA
Range 0x0-0xFF
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-NBR-EUTRAN/CHG-NBR-EUTRAN/CRTE-NBR-EUTRAN/
DLT-NBR-EUTRAN
Engineering rules This parameter indicates the Cell Number of the Neighbor
EUTRAN Cell. This information is exchanged between eNBs via X2
messages, and is used for Handovers.
Caution/Note The information must be entered accurately because Handover
success or failure depends on this information.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-611


CHAPTER 2. Parameter Description

TARGET_GERAN_NBR_IDX
Parameter name TARGET_GERAN_NBR_IDX
Description The target GERAN neighbor cell index where the blind CCO will be
performed for the relevant cell.
Object class & hierarchy PLDBlindCCOconf
Type Static
Data Type word32
Unit NA
Range 0-256
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-GERAN-BLCCO, CHG-GERAN-BLCCO
Engineering rules This is the parameter for specifying the Target GERAN Cell for
executing the GERAN Blind CCO. The corresponding parameter
must be set to the Index value of the GERAN Neighboring Cell List.
Caution/Note If the corresponding parameter indicates a Neighboring Index that
is not registered, the GERAN Blind CCO does not activate.
Delta NA
Real time change Yes
Need to reset No

2-612 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T_EVALULATION
Parameter name T_EVALULATION
Description Evaluation time of the cell in the eNB
Object class & hierarchy PLDMobilityStateInfoLogic
Type Static
Data Type short
Unit sec
Range 0-4
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-MOBIL-STA/CHG-MOBIL-STA
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_SERVING_LOW
Parameter name THRESH_SERVING_LOW
Description The low threshold for serving frequency upon reselection
evaluation.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Srxlev threshold (in dB) used by the UE on the
serving cell when reselectingtowards a lower priority
RAT/frequency.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-613


CHAPTER 2. Parameter Description

THRESH_SERVING_LOW_QREL9
Parameter name THRESH_SERVING_LOW_QREL9
Description The threshServingLowQ value for Rel-9
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Squal threshold (in dB) used by the UE on the
serving cell when reselectingtowards a lower priority RAT/
frequency for Rel9.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_SERVING_LOW_QREL9_USAGE
Parameter name THRESH_SERVING_LOW_QREL9_USAGE
Description Indicates whether to use the threshServingLowQ for Rel-9.
- CI_no_use: threshServingLowQ is not used.
- CI_use: threshServingLowQ is used.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range CI_no_use/CI_use
Read/Write Read/Write
Default value CI_no_use
Rec. Value CI_no_use
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This parameter is for setting whether or not the
threshServingLowQRel9 is used by the system.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-614 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

THRESH_XHIGH
Parameter name THRESH_XHIGH
Description The threshold used by the UE when reselecting the frequency with
priority higher than the currently camped frequency
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Srxlev threshold (in dB) used by the UE when
reselecting towards a higher priority RAT/frequency than the
current serving frequency.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XHIGH
Parameter name THRESH_XHIGH
Description The threshXhigh information used for call reselection in the
GERAN FA object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the maximum Rx Level for Cell
Reselection.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-615


CHAPTER 2. Parameter Description

THRESH_XHIGH
Parameter name THRESH_XHIGH
Description The threshold used by the UE when reselecting the frequency with
priority higher than the currently camped frequency
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type int
Unit NA
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules The threshold used by the UE when reselecting the frequency with
the priority higher than that of the currently camped frequency.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XHIGH
Parameter name THRESH_XHIGH
Description The threshold used by the UE when reselecting the frequency with
priority higher than the currently camped frequency
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter indicates the maximum Rx Level for Cell
Reselection.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-616 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

THRESH_XHIGH_QREL9
Parameter name THRESH_XHIGH_QREL9
Description The threshold used by the UE when reselecting the frequency with
priority higher than the currently camped frequency, in the Rel-9.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Squal threshold (in dB) used by the UE when
reselecting towards a higher priority RAT/frequency than the
current serving frequency.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XHIGH_QREL9
Parameter name THRESH_XHIGH_QREL9
Description The threshold used by the UE when reselecting the frequency with
priority higher than the currently camped frequency, in the Rel-9.
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type word16
Unit NA
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-617


CHAPTER 2. Parameter Description

THRESH_XHIGH_QREL9
Parameter name THRESH_XHIGH_QREL9
Description The threshold used by the UE when reselecting the frequency with
priority higher than the currently camped frequency, in the Rel-9.
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter indicates the maximum Rx Level for Cell
Reselection in Rel 9.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XLOW
Parameter name THRESH_XLOW
Description The threshold used to reselect the low-priority frequency from the
high-priority frequency
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Srxlev threshold (in dB) used by the UE when
reselecting towards a lower priority RAT/frequency than the current
serving frequency.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-618 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

THRESH_XLOW
Parameter name THRESH_XLOW
Description The threshXLow information used for call reselection in the
GERAN FA object.
Object class & hierarchy PLDGeranFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-GERAN-FA/CHG-GERAN-FA
Engineering rules This parameter indicates the minimum Rx Level for Cell
Reselection.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XLOW
Parameter name THRESH_XLOW
Description The threshold used to reselect the low-priority frequency from the
high-priority frequency
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type int
Unit NA
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-619


CHAPTER 2. Parameter Description

THRESH_XLOW
Parameter name THRESH_XLOW
Description The threshold used to reselect the low-priority frequency from the
high-priority frequency
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type int
Unit dB
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter indicates the minimum Rx Level for Cell Reselection.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XLOW_QREL9
Parameter name THRESH_XLOW_QREL9
Description In the Rel-9, the threshold used to reselect the low-priority
frequency from the high-priority frequency
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 31
Rec. Value 31
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules This specifies the Srxlev threshold (in dB) used by the UE when
reselecting towards a lower priority RAT/frequency than the current
serving frequency for Rel9.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-620 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

THRESH_XLOW_QREL9
Parameter name THRESH_XLOW_QREL9
Description In the Rel-9, the threshold used to reselect the low-priority
frequency from the high-priority frequency
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type word16
Unit NA
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

THRESH_XLOW_QREL9
Parameter name THRESH_XLOW_QREL9
Description In the Rel-9, the threshold used to reselect the low-priority frequency
from the high-priority frequency
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type word16
Unit dB
Range 0-31
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter indicates the minimum Rx Level for Cell Reselection
in the Rel.9.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-621


CHAPTER 2. Parameter Description

T_HYST_NORMAL
Parameter name T_HYST_NORMAL
Description The hyst normal time of the cell in the eNB
Object class & hierarchy PLDMobilityStateInfoLogic
Type Static
Data Type short
Unit NA
Range ci_T_Evalulation_s30/ci_T_Evalulation_s60/ci_T_Evalulation_s120/
ci_T_Evalulation_s180/ci_T_Evalulation_s240
Read/Write Read/Write
Default value ci_T_Evalulation_s30
Rec. Value ci_T_Evalulation_s30
Commands RTRV-MOBIL-STA/CHG-MOBIL-STA
Engineering rules The hyst normal time of the cell in the eNB.
- ci_T_Evalulation_s30
- ci_T_Evalulation_s60
- ci_T_Evalulation_s120
- ci_T_Evalulation_s180
- ci_T_Evalulation_s240
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-622 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the Event A1. The timeToTrigger is the
time which should be satisfied for the UE to trigger the measurement
report.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms480
Rec. Value ci_TimeToTrigger_ms480
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules A system overload can occur if a new setting is applied to the active
UE while changing parameters. Apply the new setting to the UE
during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile operation
(e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-623


CHAPTER 2. Parameter Description

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the Event A2. The timeToTrigger is the
time which should be satisfied for the UE to trigger the
measurement report.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms480
Rec. Value ci_TimeToTrigger_ms480
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-624 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the Event A3. The timeToTrigger is the
time which should be satisfied for the UE to trigger the
measurement report.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms480
Rec. Value ci_TimeToTrigger_ms480
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-625


CHAPTER 2. Parameter Description

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the Event A4. The timeToTrigger is the
time which should be satisfied for the UE to trigger the measurement
report.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms480
Rec. Value ci_TimeToTrigger_ms480
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules A system overload can occur if a new setting is applied to the active
UE while changing parameters. Apply the new setting to the UE
during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile operation
(e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-626 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the Event A5. The timeToTrigger is the
time which should be satisfied for the UE to trigger the measurement
report.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms480
Rec. Value ci_TimeToTrigger_ms480
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the active
UE while changing parameters. Apply the new setting to the UE
during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile operation
(e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-627


CHAPTER 2. Parameter Description

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The time required for the UE to trigger the measurement report
through the GERAN B1 Event Report
Object class & hierarchy PLDGeranB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms80
Rec. Value ci_TimeToTrigger_ms80
Commands RTRV-GERAN-B1CNF/CHG-GERAN-B1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-628 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The time required for the UE to trigger the measurement report
through the GERAN B2 Event Report
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms80
Rec. Value ci_TimeToTrigger_ms80
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-629


CHAPTER 2. Parameter Description

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the UTRA Event B1. The timeToTrigger
is the time which should be satisfied for the UE to trigger the
measurement report.
Object class & hierarchy PLDUtraB1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms80
Rec. Value ci_TimeToTrigger_ms80
Commands RTRV-UTRA-B1CNF/CHG-UTRA-B1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-630 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TIME_TO_TRIGGER
Parameter name TIME_TO_TRIGGER
Description The timeToTrigger value for the UTRA Event B2. The timeToTrigger
is the time which should be satisfied for the UE to trigger the
measurement report.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_TimeToTrigger_ms0/ci_TimeToTrigger_ms40/
ci_TimeToTrigger_ms64/ci_TimeToTrigger_ms80/
ci_TimeToTrigger_ms100/ci_TimeToTrigger_ms128/
ci_TimeToTrigger_ms160/ci_TimeToTrigger_ms256/
ci_TimeToTrigger_ms320/ci_TimeToTrigger_ms480/
ci_TimeToTrigger_ms512/ci_TimeToTrigger_ms640/
ci_TimeToTrigger_ms1024/ci_TimeToTrigger_ms1280/
ci_TimeToTrigger_ms2560/ci_TimeToTrigger_ms5120
Read/Write Read/Write
Default value ci_TimeToTrigger_ms80
Rec. Value ci_TimeToTrigger_ms80
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-631


CHAPTER 2. Parameter Description

TIME_TO_TRIGGER_SF_HIGH
Parameter name TIME_TO_TRIGGER_SF_HIGH
Description The speed state scale factors for scaling of the mobility-related
control parameters when the UE  is in a high speed state.
- 0: 0.25 is used for high timer value.
- 1: 0.5 is used for high timer value.
- 2: 0.75 is used for high timer value.
- 3: 1.0 is used for high timer value.
Object class & hierarchy PLDMeasurementInfoFunc
Type Static
Data Type int
Unit NA
Range ci_oDot25, ci_oDot5, ci_oDot75, ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-MEAS-FUNC/CHG-MEAS-FUNC
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-632 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TIME_TO_TRIGGER_SF_MEDIUM
Parameter name TIME_TO_TRIGGER_SF_MEDIUM
Description The speed state scale factors for scaling of the mobility-related
control parameters when the UE  is in a medium speed state.
- ci_oDot25: 0.25 is used for medium timer value.
- ci_oDot5: 0.5 is used for medium timer value.
- ci_oDot75: 0.75 is used for medium timer value.
- ci_1Dot0: 1.0 is used for medium timer value.
Object class & hierarchy PLDMeasurementInfoFunc
Type Static
Data Type enum
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-MEAS-FUNC/CHG-MEAS-FUNC
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-633


CHAPTER 2. Parameter Description

TRACKING_AREA_CODE
Parameter name TRACKING_AREA_CODE
Description The tracking area code (TAC) used by the cell in operation
It is used for transmission and stop of warning message during
paging to the UE. This information is broadcast to the UE through
the SIB 1.
Object class & hierarchy PLDEutranCellInfo
Type Static
Data Type word16
Unit NA
Range 0x0-0xFFFF
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-CELL-INFO/CHG-CELL-INFO
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-634 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T_RESELECTION
Parameter name T_RESELECTION
Description Reselection timer value
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type int
Unit sec
Range 0-7
Read/Write Read/Write
Default value 1
Rec. Value 1
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The tReselection concerns the cell reselection timer tReselection for
E-UTRA. Value in seconds.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

T_RESELECTION
Parameter name T_RESELECTION
Description Reselection timer value in the eNB
Object class & hierarchy PLDGeranReselectInfoLogic
Type Static
Data Type word16
Unit sec
Range 0-7
Read/Write Read/Write
Default value 1
Rec. Value 1
Commands RTRV-GERAN-RESEL/CHG-GERAN-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-635


CHAPTER 2. Parameter Description

T_RESELECTION
Parameter name T_RESELECTION
Description UTRAN FA reselection timer value (in second)
Object class & hierarchy PLDUtraReselectInfoLogic
Type Static
Data Type word16
Unit sec
Range 0-7
Read/Write Read/Write
Default value 1
Rec. Value 1
Commands RTRV-UTRA-RESEL/CHG-UTRA-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-636 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T_RESELECTION_SF_HIGH
Parameter name T_RESELECTION_SF_HIGH
Description The high timer value of the reselection scaling factor.
- ci_oDot25: 0.25 is used for high timer value.
- ci_oDot5: 0.5 is used for high timer value.
- ci_oDot75: 0.75 is used for high timer value.
- ci_1Dot0: 1.0 is used for high timer value.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The tReselectionSfHighconcerns factors, to be applied when the
UE is in highspeed state, used for scaling a re-selectionrelated
parameter.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-637


CHAPTER 2. Parameter Description

T_RESELECTION_SF_HIGH
Parameter name T_RESELECTION_SF_HIGH
Description The high timer value of the scaling factor related to the GERAN
reselection in the eNB
- ci_oDot25: 0.25 is used for high timer value.
- ci_oDot5: 0.5 is used for high timer value.
- ci_oDot75: 0.75 is used for high timer value.
- ci_1Dot0: 1.0 is used for high timer value.
Object class & hierarchy PLDGeranReselectInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-GERAN-RESEL/CHG-GERAN-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-638 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T_RESELECTION_SF_HIGH
Parameter name T_RESELECTION_SF_HIGH
Description The high timer value of the scaling factor related to the UTRAN FA
reselection
- ci_oDot25: 0.25 is used for high timer value.
- ci_oDot5: 0.5 is used for high timer value.
- ci_oDot75: 0.75 is used for high timer value.
- ci_1Dot0: 1.0 is used for high timer value.
Object class & hierarchy PLDUtraReselectInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-UTRA-RESEL/CHG-UTRA-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-639


CHAPTER 2. Parameter Description

T_RESELECTION_SF_MEDIUM
Parameter name T_RESELECTION_SF_MEDIUM
Description The medium timer value of the reselection scaling factor.
- ci_oDot25: 0.25 is used for medium timer value.
- ci_oDot5: 0.5 is used for medium timer value.
- ci_oDot75: 0.75 is used for medium timer value.
- ci_1Dot0: 1.0 is used for medium timer value.
Object class & hierarchy PLDEutraFaPriorInfoFunc
Type Static
Data Type word16
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-EUTRA-FA/CHG-EUTRA-FA
Engineering rules The tReselectionSfMedium concerns factors, to be applied when
the UE is in mediumspeed state, used for scaling a re-
selectionrelated parameter.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-640 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

T_RESELECTION_SF_MEDIUM
Parameter name T_RESELECTION_SF_MEDIUM
Description The medium timer value of the scaling factor related to the GERAN
reselection in the eNB
- ci_oDot25: 0.25 is used for medium timer value.
- ci_oDot5: 0.5 is used for medium timer value.
- ci_oDot75: 0.75 is used for medium timer value.
- ci_1Dot0: 1.0 is used for medium timer value.
Object class & hierarchy PLDGeranReselectInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-GERAN-RESEL/CHG-GERAN-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-641


CHAPTER 2. Parameter Description

T_RESELECTION_SF_MEDIUM
Parameter name T_RESELECTION_SF_MEDIUM
Description The medium timer value of the scaling factor related to the UTRAN
FA reselection
- ci_oDot25: 0.25 is used for medium timer value.
- ci_oDot5: 0.5 is used for medium timer value.
- ci_oDot75: 0.75 is used for medium timer value.
- ci_1Dot0: 1.0 is used for medium timer value.
Object class & hierarchy PLDUtraReselectInfoLogic
Type Static
Data Type word16
Unit NA
Range ci_oDot25/ci_oDot5/ci_oDot75/ci_1Dot0
Read/Write Read/Write
Default value ci_1Dot0
Rec. Value ci_1Dot0
Commands RTRV-UTRA-RESEL/CHG-UTRA-RESEL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-642 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TRIGGERING_CONDITION_TIMER
Parameter name TRIGGERING_CONDITION_TIMER
Description The time during which 0 continues for the RRC connection attempt
to trigger the diagnosis call. If the RRC connection does not occur
during the time, the eNB triggers the diagnosis call function.
Object class & hierarchy PLDDiagCallConf
Type Static
Data Type word32
Unit minute
Range 5-120
Read/Write Read/Write
Default value 60
Rec. Value 60
Commands RTRV-DIAG-CONF, CHG-DIAG-CONF
Engineering rules Diagnosis Signal feature is engaged if there is no signal connection
during TRIGGERING_CONDITION_TIMER.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-643


CHAPTER 2. Parameter Description

TRIGGER_QUANTITY
Parameter name TRIGGER_QUANTITY
Description The quantity used to calculate the triggering condition for Event A1.
Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDEutraA1CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-EUTRA-A1CNF/CHG-EUTRA-A1CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-644 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TRIGGER_QUANTITY
Parameter name TRIGGER_QUANTITY
Description The quantity used to calculate the triggering condition for Event A2.
Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDEutraA2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-EUTRA-A2CNF/CHG-EUTRA-A2CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-645


CHAPTER 2. Parameter Description

TRIGGER_QUANTITY
Parameter name TRIGGER_QUANTITY
Description The quantity used to calculate the triggering condition for Event A3.
Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDEutraA3CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-EUTRA-A3CNF/CHG-EUTRA-A3CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-646 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TRIGGER_QUANTITY
Parameter name TRIGGER_QUANTITY
Description The quantity used to calculate the triggering condition for Event A4.
Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDEutraA4CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-EUTRA-A4CNF/CHG-EUTRA-A4CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-647


CHAPTER 2. Parameter Description

TRIGGER_QUANTITY
Parameter name TRIGGER_QUANTITY
Description The quantity used to calculate the triggering condition for Event A5.
Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDEutraA5CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-EUTRA-A5CNF/CHG-EUTRA-A5CNF
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

2-648 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TRIGGER_QUANTITY
Parameter name TRIGGER_QUANTITY
Description The quantity used to calculate the triggering condition for EUTRA
periodic report. Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDEutraPeriodicInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-EUTRA-PRD/CHG-EUTRA-PRD
Engineering rules A system overload can occur if a new setting is applied to the
active UE while changing parameters. Apply the new setting to the
UE during a new connection request (e.g., Attach or Idle to Active)
Caution/Note If this parameter setting is changed, it will affect the mobile
operation (e.g., handover) while the UE is active.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-649


CHAPTER 2. Parameter Description

TRIGGER_QUANTITY_EUTRA
Parameter name TRIGGER_QUANTITY_EUTRA
Description The quantity used as a condition to trigger the Eutra event through
the GERAN B2 event report.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDGeranB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-GERAN-B2CNF/CHG-GERAN-B2CNF
Engineering rules This is the parameter for specifying the Trigger Quantity of the
B2Threshold1. If the corresponding parameter is RSRP, then the
B2_THRESHOLD1_RSRP setting is referenced. If the parameter is
RSRQ, then the B2_THRESHOLD1_RSRQ setting is referenced.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-650 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

TRIGGER_QUANTITY_EUTRA
Parameter name TRIGGER_QUANTITY_EUTRA
Description The EUTRA quantity used to calculate the triggering condition for
the UTRA Event B2
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set RSRQ.
Object class & hierarchy PLDUtraB2CriteriaInfo
Type Static
Data Type word16
Unit NA
Range ci_rsrp/ci_rsrq
Read/Write Read/Write
Default value ci_rsrp
Rec. Value ci_rsrp
Commands RTRV-UTRA-B2CNF/CHG-UTRA-B2CNF
Engineering rules This is the parameter for specifying the Trigger Quantity of the
B2Threshold1. If the corresponding parameter is RSRP, then the
B2_THRESHOLD1_RSRP setting is referenced. If the parameter is
RSRQ, then the B2_THRESHOLD1_RSRQ setting is referenced.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-651


CHAPTER 2. Parameter Description

2.21 U
UARFCN_DL
Parameter name UARFCN_DL
Description The Downlink UTRA Absolute Radio Frequency Channel Number
Object class & hierarchy PLDUtraCarrierInfoInSib
Type Static
Data Type short
Unit NA
Range 0-16383
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-CAR/CHG-UTRA-CAR
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-652 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

UARFCN_DL
Parameter name UARFCN_DL
Description The Downlink UTRA Absolute Radio Frequency Channel Number
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type short
Unit NA
Range 0-16383
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter sets the Downlink ARFCN value for the UTRA
Frequency. It executes Data Rule Check (DRC) to ensure that the
same Downlink ARFCN value based on the EQUIP state is not
entered.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-653


CHAPTER 2. Parameter Description

UARFCN_UL
Parameter name UARFCN_UL
Description The Uplink UTRA Absolute Radio Frequency Channel Number
Object class & hierarchy PLDUtraFaPriorInfoFunc
Type Static
Data Type short
Unit NA
Range 0-16383
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-FA/CHG-UTRA-FA
Engineering rules This parameter sets the Uplink ARFCN value for the UTRA
Frequency. It executes Data Rule Check (DRC) to ensure that the
same Uplink ARFCN value based on the EQUIP state is not
entered.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-654 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

UL_ANT_COUNT
Parameter name UL_ANT_COUNT
Description Number of Rx antennas used in the cell in operation.
- ci_n2TxAntCnt: 2 Rx antennas are used.
- ci_n4TxAntCnt: 4 Rx antennas are used.
- ci_n6TxAntCnt: 6 Rx antennas are used.
- ci_n8TxAntCnt: 8 Rx antennas are used.
- ci_n10TxAntCnt: 10 Rx antennas are used.
- ci_n12TxAntCnt: 12 Rx antennas are used.
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type word32
Unit NA
Range ci_n2RxAntCnt/ci_n4RxAntCnt/ci_n6RxAntCnt/ci_n8RxAntCnt/
ci_n10RxAntCnt/ci_n12RxAntCnt
Read/Write Read/Write
Default value ci_n2RxAntCnt
Rec. Value ci_n2RxAntCnt
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-655


CHAPTER 2. Parameter Description

UL_BANDWIDTH
Parameter name UL_BANDWIDTH
Description The uplink bandwidth used in the cell in operation
- ci_SystemBandwidth_n6: 1.4 MHz bandwidth which uses the 6
physical resource blocks (RBs)
- ci_SystemBandwidth_n15: 3 MHz bandwidth which uses 15
physical RBs
- ci_SystemBandwidth_n25: 5 MHz bandwidth which uses 25
physical RBs
- ci_SystemBandwidth_n50: 10 MHz bandwidth which uses 50
physical RBs
- ci_SystemBandwidth_n75: 15 MHz bandwidth which uses 75
physical RBs
- ci_SystemBandwidth_n100: 20 MHz bandwidth which uses 100
physical RBs
Object class & hierarchy PLDEutranCellConfIdle
Type Static
Data Type short
Unit NA
Range ci_SystemBandwidth_n6/ci_SystemBandwidth_n15/
ci_SystemBandwidth_n25/ci_SystemBandwidth_n50/
ci_SystemBandwidth_n75/ci_SystemBandwidth_n100
Read/Write Read/Write
Default value ci_SystemBandwidth_n50
Rec. Value ci_SystemBandwidth_n50
Commands RTRV-CELL-IDLE/CHG-CELL-IDLE
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-656 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

UL_GBRUSAGE_THRESH_HO
Parameter name UL_GBRUSAGE_THRESH_HO
Description The GBR percentage value available for uplink assignment for the
handover call. If the usage of uplink GBR PRB exceeds the
entered parameter ratio when handover call is requested, the QoS
CAC Fail is generated.
Object class & hierarchy PLDQosCacParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write Read/Write
Default value 100
Rec. Value 100
Commands RTRV-QCAC-PARA/CHG-QCAC-PARA
Engineering rules It is the percentage value of the GBR that can be allocated to the
Uplink of a Handover signal.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-657


CHAPTER 2. Parameter Description

UL_GBRUSAGE_THRESH_NORMAL
Parameter name UL_GBRUSAGE_THRESH_NORMAL
Description The GBR percentage value available for uplink assignment for a
new call. If the usage of uplink GBR PRB exceeds the entered
parameter ratio when a new call is requested, the QoS CAC Fail is
generated.
Object class & hierarchy PLDQosCacParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write Read/Write
Default value 80
Rec. Value 80
Commands RTRV-QCAC-PARA/CHG-QCAC-PARA
Engineering rules It is the percentage value of the GBR that can be allocated to the
Uplink of a Normal signal.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-658 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

UL_QCIUSAGE_THRESH_HO
Parameter name UL_QCIUSAGE_THRESH_HO
Description The PRB percentage value available for uplink assignment for the
handover call per the QoS class identifier (QCI). If the usage of
uplink GBR PRB exceeds the entered parameter value when
handover call is requested, the QoS CAC Fail is generated.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write Read/Write
Default value 100
Rec. Value 100
Commands RTRV-QCACQ-PARA/CHG-QCACQ-PARA
Engineering rules The threshold of Uplink Handover calls that can be assigned per
QoS Class Identifier (QCI). It is used when a Handover call is
requested. It is calculated as PRB percentage. When a Handover
call is requested, if the uplink GBR PRB usage exceeds this
parameter value, the QoS CAC Fail is generated.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-659


CHAPTER 2. Parameter Description

UL_QCIUSAGE_THRESH_NORMAL
Parameter name UL_QCIUSAGE_THRESH_NORMAL
Description The PRB percentage value available for uplink assignment for a
new call per the QoS class identifier (QCI). If the usage of uplink
GBR PRB exceeds the entered parameter value when a new call is
requested, the QoS CAC Fail is generated.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type byte
Unit %
Range 0-100
Read/Write Read/Write
Default value 80
Rec. Value 80
Commands RTRV-QCACQ-PARA/CHG-QCACQ-PARA
Engineering rules The threshold of Uplink calls that can be assigned per QoS Class
Identifier (QCI). It is used when a new call is requested.
It is calculated as PRB fpercentage. When a new call is requested,
if the uplink GBR PRB usage exceeds this parameter value, the
QoS CAC Fail is generated.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-660 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

UM_SN_SIZE
Parameter name UM_SN_SIZE
Description Size of the PDCP sequence number (SN) in the RLC UM mode
- ci_len7bits: 7 bit size (0-127) is used.
- ci_len12bits: 12 bit size (0-4095) is used (default).
Object class & hierarchy PLDPdcpInfoFunc
Type Static
Data Type word32
Unit NA
Range ci_len7bits/ci_len12bits
Read/Write Read/Write
Default value ci_len12bits
Rec. Value ci_len12bits
Commands RTRV-PDCP-INF/CHG-PDCP-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-661


CHAPTER 2. Parameter Description

UNCERTAINTY_ALTITUDE
Parameter name UNCERTAINTY_ALTITUDE
Description Uncertainty of Altitude
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word16
Unit NA
Range 0-127
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The value indicating the tolerance level of altitude, which is directly
entered by an operator. The tolerance value h can be computed by
the formula h = 45 * (1.025k-1).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

UNCERTAINTY_SEMI_MAJOR
Parameter name UNCERTAINTY_SEMI_MAJOR
Description Uncertainty of SemiMajor
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word16
Unit NA
Range 0-127
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The value indicating the tolerance level, which is directly entered
by an operator. The tolerance value can be computed by the
formula r = 10 * (1.1k-1).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-662 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

UNCERTAINTY_SEMI_MINOR
Parameter name UNCERTAINTY_SEMI_MINOR
Description Uncertainty of SemiMinor
Object class & hierarchy PLDPositioningConf
Type Static
Data Type word16
Unit NA
Range 0-127
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-POS-CONF/CHG-POS-CONF
Engineering rules The value indicating the tolerance level, which is directly entered
by an operator. The tolerance value can be computed by the
formula r = 10 * (1.1k-1).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

UNIT_USAGE_MANUAL
Parameter name UNIT_USAGE_MANUAL
Description The PRB usage percentage value for manual assignment. It is
used when the estimationOpt is 1, and the value up to the third
decimal point is valid.
Object class & hierarchy PLDQosCacQciParam
Type Static
Data Type float
Unit %
Range 0-100.000
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-QCACQ-PARA/CHG-QCACQ-PARA
Engineering rules The value of PRB usage that can be caltuated manually.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-663


CHAPTER 2. Parameter Description

UPLINK_FORWARD
Parameter name UPLINK_FORWARD
Description Indicates whether to enable the Uplink Data Forwarding in the
target eNB upon handover.
- 0: Uplink Data Forwarding is not enabled. (Not Uplink Data
Forwarding).
- 1: Uplink Data Forwarding is enabled. (Uplink Data Forwarding).
Object class & hierarchy PLDHandoverOptionInfoFunc
Type Static
Data Type int
Unit NA
Range 0-1
Read/Write Read/Write
Default value 1
Rec. Value 1
Commands RTRV-HO-OPT/CHG-HO-OPT
Engineering rules This determines whether or not to engage Forwarding on Uplink
Data during Handover.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-664 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

USED_NBR_LIST
Parameter name USED_NBR_LIST
Description Indicates the method of providing the neighbor cell list contained in
the MeasObjectEUTRA of the RRC Connection Reconfiguration
message.
- 0: Only the neighbor cells where CIO value is not dB0 are
contained in the list. (By Algorithm).
- 1: The neighbor cells where CIO value is dB0 are also contained
in the list. (Force Used).
Object class & hierarchy PLDHandoverOptionInfoFunc
Type Static
Data Type int
Unit NA
Range 0-1
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-HO-OPT/CHG-HO-OPT
Engineering rules This allows you to see the changes in the values generated during
the RRC Connection Reconfiguration message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-665


CHAPTER 2. Parameter Description

UTRA_FILTER_COEFFICIENT
Parameter name UTRA_FILTER_COEFFICIENT
Description The measurement filtering coefficient for UTRA.
Object class & hierarchy PLDQuantityConfigUtra
Type Static
Data Type word16
Unit NA
Range 0-14
Read/Write Read/Write
Default value 4
Rec. Value 4
Commands RTRV-QUANT-UTRA/CHG-QUANT-UTRA
Engineering rules If the UTRA_FILTER_COEFFICIENT value is changed, it is
referred for creating the RRC Connection Reconfiguration
message.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

UTRAN_NBR_RELATION_IDX
Parameter name UTRAN_NBR_RELATION_IDX
Description UTRAN Neighbor Relation Index
Object class & hierarchy PLDUtranSubcellRelation
Type Static
Data Type word32
Unit NA
Range 0-255
Read/Write Read/Write
Default value 0
Rec. Value 0
Commands RTRV-UTRA-SUBCELLREL/CHG-UTRA-SUBCELLREL
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-666 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.22 V
VOIP_INCAPABLE
Parameter name VOIP_INCAPABLE
Description Indicates whether the relevant GERAN neighbor cell supports the
VoIP.
- False: VoIP is supported.
- True: VoIP is not supported.
Object class & hierarchy PLDExternalGeranCellLogic
Type Dynamic
Data Type word16
Unit NA
Range False/True
Read/Write Read/Write
Default value True
Rec. Value True
Commands RTRV-NBR-GERAN/CHG-NBR-GERAN/CRTE-NBR-GERAN/
DLT-NBR-GERAN
Engineering rules This parameter indicates whether or not VoIP is supported for a
Neighbor GERAN Cell. This information is used to determine
SRVCC execution.
Caution/Note The parameter must be set accurately because the SRVCC
execution is determined by the setting.
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-667


CHAPTER 2. Parameter Description

VOIP_INCAPABLE
Parameter name VOIP_INCAPABLE
Description Indicates whether the relevant UTRAN neighbor cell supports the
VoIP.
- False: VoIP is supported.
- True: VoIP is not supported.
Object class & hierarchy PLDExternalUtranCellLogic
Type Dynamic
Data Type word32
Unit NA
Range False/True
Read/Write Read/Write
Default value True
Rec. Value True
Commands RTRV-NBR-UTRAN/CHG-NBR-UTRAN/CRTE-NBR-UTRAN/
DLT-NBR-UTRAN
Engineering rules This parameter indicates whether or not VoIP is supported for a
Neighbor UTRAN Cell. This information is used to determine
SRVCC execution.
Caution/Note The parameter must be set accurately because the SRVCC
execution is determined by the setting.
Delta NA
Real time change Yes
Need to reset No

2-668 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

2.23 W
WARNING_MSG_TYPE
Parameter name WARNING_MSG_TYPE
Description Determines the warning message type.
- etws: Earthquake and Tsunami Warning System(SIB10, 11)
- cmas: Commercial Mobile Alert System(SIB12)
Object class & hierarchy PLDSibSchedulingInfoLogic
Type Static
Data Type enum
Unit NA
Range etws/cmas
Read/Write Read/Write
Default value etws
Rec. Value etws
Commands RTRV-SIB-INF/CHG-SIB-INF
Engineering rules -
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-669


CHAPTER 2. Parameter Description

2.24 X
X2_HANDOVER_PREPARATION
Parameter name X2_HANDOVER_PREPARATION
Description The waiting time to receive the HandoverRequestAcknowledge
message after the source eNB sends the HandoverRequest
message to the target eNB.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 2000
Rec. Value 2000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for the X2 Handover Preparation process. It is the
timer for receiving the Handover Request Acknowledge message
from the Target eNB after transmitting the Handover Request from
the Source eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-670 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

X2_RELOC_OVERALL
Parameter name X2_RELOC_OVERALL
Description Time of waiting for the UEContextRelease message from the target
eNB when handover is completed after receiving the
HandoverRequestAcknowledge message from the target eNB.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer for receiving the UE Context Release message
from the Target eNB after transmitting the RRC Reconfiguration
message from the Source eNB to a device executing the X2
Handover. The call in progress is dropped when the timer expires.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-671


CHAPTER 2. Parameter Description

X2_SETUP
Parameter name X2_SETUP
Description The waiting time to receive the X2SetupResponse or
X2SetupFailure message after the eNB sends the
X2SetupRequest message to other eNB
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the X2 Setup process timer value, used for the Naver
setting.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-672 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

X2_SETUP_TIME_TO_WAIT
Parameter name X2_SETUP_TIME_TO_WAIT
Description The TimetoWait value included in the X2SetupFailure message
which is sent by the eNB which received the X2SetupRequest.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type enum
Unit NA
Range ci_v1s/ci_v2s/ci_v5s/ci_v10s/ci_v20s/ci_v60s
Read/Write Read/Write
Default value ci_v5s
Rec. Value ci_v5s
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value that must be included in a message if an X2
Setup Failure message needs to be transmitted. The failure can be
a problem within a Base Station after receiving the X2 Setup
Request message from another Base Station.
- ci_v1s: 1 s
- ci_v2s: 2 s
- ci_v5s: 3 s
- ci_v10s: 10 s
- ci_v20s: 20 s
- ci_v60s: 60 s
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-673


CHAPTER 2. Parameter Description

X2_STORE_UE_CONTEXT
Parameter name X2_STORE_UE_CONTEXT
Description Time to determine whether to send the Handover Report message
when the SON Mobility Robustness Optimization (MRO) function
receives the RLF Indication message.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 10000
Rec. Value 10000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value for determining Handover Report message
transmission when operating SON Mobility Robustness
Optimization (MRO).
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-674 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

X2_UPDATE
Parameter name X2_UPDATE
Description The waiting time to receive the
EnbConfigurationUpdateAcknowledge or
EnbConfigurationUpdateFailure message after the eNB sends the
EnbConfigurationUpdate message to other eNB designated as a
neighbor.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type int
Unit msec
Range 10-65535
Read/Write Read/Write
Default value 5000
Rec. Value 5000
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value used during X2 ENB Configuration Update.
It is the timer for receiving an X2 ENB Configuration Update
Acknowlede message from the Target eNB after transmitting X2
EnbConfiguration Update message from the Source eNB.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-675


CHAPTER 2. Parameter Description

X2_UPDATE_RETRY_COUNT
Parameter name X2_UPDATE_RETRY_COUNT
Description The retry count to perform the eNB configuration update procedure
when the X2 eNBConfigurationUpdateFailure message is received
from the MME or timeout occurs after the eNB sends the X2
eNBConfigurationUpdate message.
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type enum
Unit NA
Range ci_CountZero/ci_CountOne/ci_CouintTwo/ci_CountThree/
ci_CountTen/ci_CountInfinity
Read/Write Read/Write
Default value ci_CountThree
Rec. Value ci_CountThree
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This parameter indicates the retry count in case of an X2 Update
failure.
- ci_CountZero: no retry is attempted.
- ci_CountOne: retry is attempted 1 time.
- ci_CountTwo: retry is attempted 2 times.
- ci_CountThree: retry is attempted 3 times.
- ci_CountTen: retry is attempted 10 times.
- ci_CountInfinity: retry is attempted an infinite number of times.
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

2-676 © SAMSUNG Electronics Co., Ltd.


LTE eNB Call Parameter Description/Ver.1.0

X2_UPDATE_TIME_TO_WAIT
Parameter name X2_UPDATE_TIME_TO_WAIT
Description The TimetoWait value included upon sending the
ENBConfigurationUpdateFailure (Default 2 seconds).
Object class & hierarchy PLDTimerInfoPhy
Type Static
Data Type enum
Unit NA
Range ci_v1s/ci_v2s/ci_v5s/ci_v10s/ci_v20s/ci_v60s
Read/Write Read/Write
Default value ci_v5s
Rec. Value ci_v5s
Commands RTRV-TIMER-INF/CHG-TIMER-INF
Engineering rules This is the timer value that is included when transmitting the X2
eNB Configuration Update Failure message.
- ci_v1s: 1 sec
- ci_v2s: 2 sec
- ci_v5s: 5 sec
- ci_v10s: 10 sec
- ci_v20s: 20 sec
- ci_v60s: 60 sec
Caution/Note NA
Delta NA
Real time change Yes
Need to reset No

© SAMSUNG Electronics Co., Ltd. 2-677


CHAPTER 2. Parameter Description

This page is intentionally left blank.

2-678 © SAMSUNG Electronics Co., Ltd.


LTE eNB
Call Parameter Description

©2013 Samsung Electronics Co., Ltd.


All rights reserved.

Information in this manual is proprietary to SAMSUNG


Electronics Co., Ltd.
No information contained here may be copied, translated,
transcribed or duplicated by any form without the prior written
consent of SAMSUNG.
Information in this manual is subject to change without notice.

Anda mungkin juga menyukai