Anda di halaman 1dari 2

LABORATORIUM MEKANIKA TANAH

FAKULTAS TEKNIK SIPIL DAN PERENCANAAN


INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

PERMEABILITY TEST
(Falling Head)

Location : Order
Sample type : UDS Date :
Depth : 2.5 m Sample No. :

Diameter (D) = 10.1 cm


Height (L) = 14.6 cm
Area (A) = 80.15071 cm2
Volume (V) = 1170.2 cm3

Diam. pipe (d) = 1.15 cm


Area of pipe (a) = 1.039107 cm2

t1 = 0 menit h1 = 160.0 cm
t1
t2 = 1 menit h2 = 104.00 cm
t2 = 2 menit h2 = 75.50 cm
t2 h1− h2
Gradient Hydrolic i= = 3.835616438
h1 L
h2
Coefisient permeabilitas
t2 = 6 menit
h
L
k ¿ 2, 303
a. L
A x t ( )
log 1 = 0.001359225 cm/sec
h2 = 1.36E-03 cm/sec
t2 = 9.0 menit
h
k ¿ 2, 303
a. L
A x t h2 ( )
log 1 = 0.001184859 cm/sec
1.18E-03 cm/sec
Interval Height koeficient
Start time Time water in pipa permeability
t (menit) h (cm) ( cm/sec )
3 104.0
6 75.5 0.000336831
9 53.0 0.000354491
12 39.5 0.000339396
0.000343572
krata-rata
3.4357E-04