PERMEABILITY TEST
(Falling Head)
Location : Order
Sample type : UDS Date :
Depth : 2.5 m Sample No. :
t1 = 0 menit h1 = 160.0 cm
t1
t2 = 1 menit h2 = 104.00 cm
t2 = 2 menit h2 = 75.50 cm
t2 h1− h2
Gradient Hydrolic i= = 3.835616438
h1 L
h2
Coefisient permeabilitas
t2 = 6 menit
h
L
k ¿ 2, 303
a. L
A x t ( )
log 1 = 0.001359225 cm/sec
h2 = 1.36E-03 cm/sec
t2 = 9.0 menit
h
k ¿ 2, 303
a. L
A x t h2 ( )
log 1 = 0.001184859 cm/sec
1.18E-03 cm/sec
Interval Height koeficient
Start time Time water in pipa permeability
t (menit) h (cm) ( cm/sec )
3 104.0
6 75.5 0.000336831
9 53.0 0.000354491
12 39.5 0.000339396
0.000343572
krata-rata
3.4357E-04