Anda di halaman 1dari 1

Common Rail NEF engines - CNH

Complete the assembly operation by


performing the disassembly steps in reverse
order, observing the following prescriptions:
‰ Tighten the electro-injector connector
fixing nuts to the prescribed torque;
‰ Fit the high and low pressure pipes in
accordance with the procedures given in
the heading covering the main interven-
tions on the installed engine;
‰ Fill the cooling circuit with coolant and
bleed out the air.
000937t

Adjust clearance between rockers and


valves by means of Allen wrench (1), ring Checks and inspections
spanner (3) and feeler gauge (2). Start the engine, leave it running at
Operating clearance must be: slightly above idle speed, and wait for
- r 0.05 mm the coolant temperature to reach the
thermostat opening value before
- intake valves 0.25 r 0.05 mm checking that:
- exhaust valves 0.50 r 0.05 mm

In order to adjust the rocker – valves ‰ There are no leaks from the engine
operating clearance more rapidly, cooling circuit hoses and the cab heating
proceed as follows. hoses. Tighten the hose clamps
wherever necessary.
Turn the crankshaft and balance the valves
of cylinder no. 1 and adjust the clearance of
the valves marked with an asterisk in the
table:

cylinder no. 1 2 3 4 5 6
intake - - 7 - 7 7
exhaust - 7 - 7 - 7

Turn the crankshaft, balance the valves of


cylnider no. 6 and adjust the clearance of the
valves marked with an asterisk in the table:

cylinder no. 1 2 3 4 5 6
intake 7 7 - 7 - -
exhaust 7 - 7 - 7 -

112

Anda mungkin juga menyukai