FOR
WATER TREATMENT
PLANT
(ULTRAFILTRATION SYSTEM)
SIZING CALCULATION OF
ULTRAFILTRATION SYSTEM
1. Temperature 25 Deg. C
2. pH 6.5-7.5 --
3. TSS <10 Mg/Lit
4. Turbidity <5 NTU
1. Temperature 25 Deg. C
2. pH 6.5-7.5
3. TSS <1
4. Turbidity <1
1. UF FEED PUMP
Referring the projections & subsequent recovery the required net & feed flow
per skid 1.5 MLD 1.76 MLD respectively, with in 16 Hrs. Hence the selected
capacity of feed pump is OK.
2. UF BACKWASH PUMP
Referring the projections & subsequent recovery the required backwash flow
per membrane is 3.78M3/hr/Membrane .Total Membrane quantity = 40 Nos.
Hence the selected capacity of backwash pump = 151.2M3/hr, which is OK.
3. CARTRIDGE FILTER
Quantity = 1 (1 Duty)
UF recovery = 85.4 %
Quantity = 1 (1 Duty)
6. UF CIP PUMP
UF feed Pump MOC is considered as SS 316 Casing & Impeller, hence the
same pump will be used for CIP
7. CIP TANK
Quantity = 1 (1 duty)