Anda di halaman 1dari 30

INTERACTIVE SCHEMATIC

Bookmarks X

Options

Features
This document is best viewed at a
Cover Page screen resolution of 1024 X 768.
Information To set your screen resolution do the following:
Component Table
Tap Table
RIGHT CLICK on the DESKTOP.
Fluid Power Symbols Select PROPERTIES.
Electrical Symbols CLICK the SETTINGS TAB.
Schematic
MOVE THE SLIDER under SCREEN RESOLUTION
Machine Views
Front Frame
until it shows 1024 X 768.
Rear Frame CLICK OK to apply the resolution.
Tap Views

The Bookmarks panel will allow you to


quickly navigate to points of interest.

EC-C2 E-C60
EC-C3

E-C61

Click on any text that is BLUE and underlined.


These are hyperlinks that can be used to navi-
gate the schematic and machine views.

EC-C1

When only one callout is showing on a machine view this


VIEW ALL CALLOUTS button will make all of the callouts visible. This button is
located in the top right corner of every machine view page.

HOTKEYS (Keyboard Shortcuts)

FUNCTION KEYS
Zoom In “CTRL” / “+”
Zoom Out “CTRL” / “-”
Fit to Page “CTRL” / “0” (zero)
Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
KENR5117-05
January 2012

246C, 256C, 262C, 262C2, and 272C


Skid Steer Loader
Hydraulic System
246C: 256C: 262C: 262C2: 272C:
JAY1-UP DWS1-UP MST1-UP TMW1-UP RED1-UP

Volume 1 of 2: Standard Flow with ATAAC and Demand Fan


Volume 2 of 2: XPS High Flow

© 2012 Caterpillar, All Rights Reserved Printed in U.S.A.


COMPONENT LOCATION
Volume 1 of 2 - STANDARD FLOW
Part
Machine Schematic
Description Number
Location Location
246/256 262 272
Accumulator - Ride Control 307-6504 307-6504 307-6504 24 F-5
Cooler Assembly 361-4660 361-4660 361-4660 5 E-3
Coupling (Female) 193-8335 193-8335 193-8335 13 I-1
Coupling (Male) 193-8334 193-8334 193-8334 14 I-1
Cylinder Gp - Lift Cylinders 258-2512 258-2516 258-2516 17 I-3
Cylinder Gp - Quick Coupler 192-2640 192-2640 192-2640 21 D-4
Cylinder Gp - Tilt Cylinder (Left Hand) 258-2515 258-2515 258-2515 16 I-2
Cylinder Gp - Tilt Cylinder (Right Hand) 258-2514 258-2514 258-2514 15 I-2
Displacement Accumulator 193-0447 193-0447 193-0447 9 E-10
Filter Gp - Oil Filter 223-9974 223-9974 223-9974 7 C-2
Manifold Assembly - Bypass Check 258-2589 258-2589 258-2589 8 E-5
Motor Gp - Ataac Fan Motor 278-8720 11 B-3
Motor Gp - Demand Fan Motor 258-2577 258-2577 258-2577 6 C-3
Motor Gp - Single Speed Motor 258-2442 258-2442 258-2605 18 D-10
Pump Gp - Hystat Pump 258-2404 258-2404 258-2404 4 B-8
Pump Gp - Implement/ Charge / Ataac Pump 258-3464
2 B-6
Pump Gp - Implement/ Charge / Ataac Pump (Eu) 258-3520
Pump Gp - Implement/ Charge Pump 258-2553 258-2553
1 B-7
Pump Gp - Implement/ Charge Pump (Eu) 258-3260 258-3260
Tank Gp - Tank 258-2831 258-2831 258-2831 3 A-4
Valve Gp - Manual Ball Valve 112-1817 112-1817 112-1817 19 G-6
Valve Gp - Pilot Shutoff Valve 274-8563 274-8563 274-8563 10 F-9
Valve Gp - Pre Charge 307-2276 307-2276 307-2276 25 F-5
Valve Gp - Quick Coupler 291-0010 291-0010 291-0010 22 D-4
Valve Gp - Ride Control 307-2275 307-2275 307-2275 23 G-5
Valve Gp - Single Self Level Valve 258-2801 258-2802 258-2802 20 I-6
Valve Gp - Standard Implement Valve 336-1322 336-1324 336-1324 12 F-2
Two Speed Option
Motor Gp - 2 Speed Motor (Left Hand) 258-2520 258-2520 258-2835 28 H-9
Motor Gp - 2 Speed Motor (Right Hand) 258-2521 258-2521 258-2836 27 H-7
Pump Gp - Hystat Pump 258-2404 258-2404 258-2404 26 F-7
Valve Gp - 2 Speed Valve 274-8564 274-8564 274-8564 29 I-8
XDP Option
Motor Gp - Hystat Motor 285-2605 285-2605 285-2605 31 H-12
Pump Gp - Hystat Pump 289-6362 289-6362 289-6362 30 F-11
Additional
Valve Gp - Check 304-6756 304-6756 304-6756 32 F-5
COMPONENT LOCATION
Volume 2 of 2 - XPS HIGH FLOW
Part
Machine Schematic
Description Number
Location Location
246/256 262 272
Accumulator - Implement Valve Charge 193-0447 1 E-10
Accumulator - Ride Control 307-6504 2 F-5
Cooler Assembly 258-3457 3 E-3
Coupling (Female) 1 218-5841 4 I-1
Coupling (Female) 2 229-5471 5 I-4
Coupling (Male) 1 218-5840 6 I-1
Coupling (Male) 2 229-5468 7 I-4
Coupling (Male) 3 229-5473 8 I-4
Cylinder Gp - Lift 258-2512 258-2516 9 I-3
Cylinder Gp - Quick Coupler 192-2640 10 E-4
Cylinder Gp - Tilt (Left Hand) 258-2515 11 I-2
Cylinder Gp - Tilt (Right Hand) 258-2514 12 I-2
Filter Gp - Oil 223-9974 13 C-2
Manifold Assembly - Bypass Check 308-0421 14 E-5
Motor Gp - 2 Speed (Left Hand) 258-2520 258-2835 15 H-9
Motor Gp - 2 Speed (Right Hand) 258-2521 258-2836 16 H-7
Motor Gp - Ataac Fan 258-2926 17 B-3
Motor Gp - Beta Single Speed 258-2442 258-2605 18 D-10
Motor Gp - Demand Fan 258-2577 19 D-3
Motor Gp - Hystat 285-2605 20 H-12
Orifice 6V-8627 21 A-3
Pump Gp - Charge And Ataac 258-3521
22 B-3
Pump Gp - Charge And Ataac (Eu) 258-2555
Pump Gp - Charge 258-2555
23 B-4
Pump Gp - Charge (Eu) 258-3261
Pump Gp - Hystat 289-6362 24 F-11, F-7
Pump Gp - Implement 258-2554 25 B-5
Pump Gp - Ssl Drive 258-2404 26 B-8
Tank Gp 258-2831 27 B-3
Valve Gp - 2 Speed 274-8564 28 I-8
Valve Gp - Check 304-6756 29 F-5
Valve Gp - Check 314-2403 30 F-5
Valve Gp - Manual Ball 112-1817 31 G-6
Valve Gp - Pilot Shutoff 274-8563 32 E-9
Valve Gp - Quick Coupler 291-0010 33 D-4
Valve Gp - Ride Control Accumulator Precharge 307-2276 34 F-5
Valve Gp - Ride Control 307-2275 35 G-5
Valve Gp - Single Self Level 258-2801 258-2802 36 I-5
Valve Gp - Xps Implement 336-1323 37 F-2
TAP LOCATION
Volume 1 of 2 - STANDARD FLOW

Tap Schematic
Description
Number Location
BB SOS D-3
EE Charge Pressure H-8, H-12, C-9
PO Pilot Oil Pressure H-1
MC Main System Pressure (Pump 1 Forward) H-8, H-12, C-10
MB Main System Pressure (Pump 2 Forward) H-7, H-11, C-9
MA Main System Pressure (Pump 2 Reverse) F-7, F-11, B-9
MD Main System Pressure (Pump 1 Reverse) F-8, F-12, B-10
TAP LOCATION
Volume 2 of 2 - XPS HIGH FLOW

Tap Schematic
Description
Number Location
AA Load Sense C-4
BB SOS D-3
CC Implement Pump Pressure F-4
EE Charge Pressure H-8, H-12, C-9
PO Pilot Oil Pressure H-1
MC Main System Pressure (Pump 1 Forward) H-8, H-12, C-10
MB Main System Pressure (Pump 2 Forward) H-7, H-11, C-9
MA Main System Pressure (Pump 2 Reverse) F-11, F-7, A-9
MD Main System Pressure (Pump 1 Reverse) F-12, F-8, A-10
FLUID POWER SYMBOLS
BASIC COMPONENT SYMBOLS

MAIN AUX.
PUMP: VARIABLE and
PUMP or MOTOR FLUID CONDITIONER SPRING CONTROL VALVES RESTRICTION LINE RESTRICTION 2-SECTION PUMP PRESSURE COMPENSATED
(FIXED)

VARIABILITY SPRING LINE RESTRICTION PRESSURE HYDRAULIC PNEUMATIC LINE RESTRICTION ATTACHMENT
(ADJUSTABLE) (VARIABLE) COMPENSATION ENERGY TRIANGLES VARIABLE and PRESSURE
COMPENSATED

VALVE ENVELOPES
VALVES
VALVE PORTS

ONE POSITION TWO POSITION THREE POSITION TWO-WAY THREE-WAY FOUR-WAY

CONTROL VALVES CHECK VALVES


AB AB

P T P T
BASIC SPRING SHUTTLE PILOT
NORMAL POSITION SHIFTED POSITION INFINITE POSITION
SYMBOL LOADED CONTROLLED

FLUID STORAGE RESERVOIRS

VENTED PRESSURIZED RETURN ABOVE FLUID LEVEL RETURN BELOW FLUID LEVEL

MEASUREMENT ROTATING SHAFTS

PRESSURE TEMPERATURE FLOW UNIDIRECTIONAL BIDIRECTIONAL

COMBINATION CONTROLS

SOLENOID SOLENOID SOLENOID SOLENOID and SERVO THERMAL DETENT


or MANUAL and PILOT PILOT or MANUAL

MANUAL CONTROL SYMBOLS

PUSH-PULL LEVER MANUAL SHUTOFF GENERAL MANUAL PUSH BUTTON PEDAL SPRING

RELEASED PRESSURE PILOT CONTROL SYMBOLS


REMOTE SUPPLY PRESSURE

EXTERNAL RETURN INTERNAL RETURN SIMPLIFIED COMPLETE INTERNAL


SUPPLY PRESSURE

ACCUMULATORS CROSSING AND JOINING LINES HYDRAULIC AND PNEUMATIC CYLINDERS

SPRING LOADED GAS CHARGED LINES CROSSING LINES JOINING SINGLE ACTING DOUBLE ACTING

HYDRAULIC PUMPS HYDRAULIC MOTORS INTERNAL PASSAGEWAYS

FIXED VARIABLE DISPLACEMENT FIXED VARIABLE DISPLACEMENT INFINITE THREE TWO


DISPLACEMENT NON-COMPENSATED DISPLACEMENT NON-COMPENSATED POSITIONING POSITION POSITION

UNIDIRECTIONAL UNIDIRECTIONAL

FLOW IN ONE PARALLEL CROSS FLOW ALLOWED IN


BIDIRECTIONAL BIDIRECTIONAL DIRECTION FLOW FLOW EITHER DIRECTION
ELECTRICAL SYMBOLS
Hydraulic Symbols (Electrical)

G M
Transducer Transducer Generator Electric Motor
(Fluid) (Gas / Air)

Pressure Switch Pressure Switch Temperature Switch Electrical Wire


(Adjustable)

Electrical Symbols (Electrical)

Pressure Temperature Level Flow


Symbol Symbol Symbol Symbol

Wire Number Identification Codes

Electrical Schematic Example Hydraulic Schematic Example

Current Standard Current Standard


Harness identification code
This example indicates
wire 135 in harness "AG". Wire
Circuit Number Wire Color
Identification

325-AG135 PK-14
325-PK
Circuit Identification Wire Color Wire Gauge
Number

Previous Standard
Wire Color
Wire

325-PK-14
B A
Circuit Number Wire Gauge
Identification (EXAMPLE VALVE)
13 12 11 10 9 8 7 6 5 4 3 2 1

A
(29) VALVE GP B
2 SPEED (17) CYLINDER GP - LIFT (16) CYLINDER GP (15) CYLINDER GP
E 274-8564 (20) VALVE GP 246/256: 258-2512
I TILT (LEFT HAND) TILT (RIGHT HAND) I
(31) MOTOR GP SINGLE SELF LEVEL 262/272: 258-2516 258-2515 258-2514
HYSTAT 246/256: 258-2801 AUXILIARY TOOLS
B C 262/272: 258-2802
285-2605
B C CHARGE SUPPLY
(14) COUPLING
CHARGE SUPPLY
TO PILOT SHUTOFF
Y
TO PILOT SHUTOFF
(13) COUPLING
A
I I Y
A D C FEMALE MALE
R R
193-8334
193-8335

H A H
A

PO
X X

(28) MOTOR GP (27) MOTOR GP


2 SPEED (LEFT HAND) 2 SPEED (RIGHT HAND)
246/256: 258-2520 246/256/262: 258-2521
262/272: 258-2835 272: 258-2836 1A 1B 2A 2B 1C 2C
MC EE MB MC EE MB
(19) VALVE GP
MANUAL BALL
C D M3 X7 A B
C D M3 X7 A B

112-1817 B
B B

G (23) VALVE GP G
RIDE CONTROL
307-2275
M M H R

T
AA

E
E (32) VALVE GP
D CHECK
MD MA (30) PUMP GP D (26) PUMP GP
CHARGE SUPPLY 304-6756
F FROM HYD FILTER
HYSTAT HYSTAT F
MD MA
CHARGE SUPPLY
FROM HYD FILTER ACC
289-6362 258-2404
(24) ACCUMULATOR
A A A
XDP OPTION TWO SPEED OPTION ACC RIDE CONTROL
307-6504
(25) VALVE GP
(10) VALVE GP
PRECHARGE
PILOT SHUTOFF (12) VALVE GP - STANDARD IMPLEMENT
307-2276
274-8563 246/256: 336-1322
(9) ACCUMULATOR
DISPLACEMENT PILOT 262/272: 336-1324
193-0447

T (5) COOLER ASSEMBLY


P 361-4660
A
E E
B
C
E

(18) MOTOR GP (21) CYLINDER GP


SINGLE SPEED QUICK COUPLER
I 246/256/262: 258-2442 I 192-2640
272: 258-2605 (8) MANIFOLD AS
R L
BYPASS CHECK
258-2589

D D

C1 C2

T P
BB
R (22) VALVE GP (7) FILTER GP - OIL
L
QUICK COUPLER 223-9974
291-0010 S B
X X G

L3 L
EE (6) MOTOR GP
MC MB DEMAND FAN
258-2577
C C
MC C D M3 X7 A B MB

HYDRAULIC CIRCUIT COLOR DESCRIPTIONS


IMPLEMENT PUMP CIRCUIT
PILOT SUPPLY CIRCUIT
CHARGE PUMP CIRCUIT
S B CHARGE PUMP AND ATAAC FAN PUMP CIRCUIT
SUPPLY LINE
DRAIN / RETURN LINE

B1 B2 B3
STEERING CIRCUIT
(11) MOTOR GP TILT CYLINDER CIRCUIT

ATAAC FAN LIFT CYLINDER CIRCUIT

M 278-8720
AUXILIARY TOOLS CIRCUIT
CONTROL COUPLING CIRCUIT
BASIC CYLINDER CIRCUIT
TRAVEL CONTROL CIRCUIT

B S1 S2
TWO SPEED CONTROL VALVE CIRCUIT
B
LINE PATTERNS
Pressure Line

Pilot / Load Sensing Pressure


(1) PUMP GP (2) PUMP GP Drain / Return Lines
MD E MA IMPLEMENT/CHARGE IMPLEMENT/CHARGE/ATAAC Component Group
(4) PUMP GP STANDARD: 258-2553 STANDARD: 258-3464
D EU: 258-3260 EU: 258-3520 Attachment
HYSTAT
MD MA 258-2404 Air Line

(3) TANK GP CALLOUTS


258-2831 YY Taps (Pressure, Sampling,Sensor) by letter
SINGLE SPEED OPTION
A A
246C, 256C, 262C, 262C2, AND 272C SKID STEER LOADER HYDRAULIC SYSTEM
VOLUME 1 of 2: STANDARD FLOW WITH ATAAC AND DEMAND FAN
MEDIA NUMBER: KENR5117-05
PART NUMBER: 258-3995, CHANGE: 06, VERSION: -
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.

13 12 11 10 9 8 7 6 5 4 3 2 1
13 12 11 10 9 8 7 6 5 4 3 2 1

A
(28) VALVE GP
2 SPEED B
274-8564 DRAIN MANIFOLD - TO TANK (9) CYLINDER GP - LIFT
CONTROL 246/256: 258-2512 (11) CYLINDER GP (12) CYLINDER GP
I 262/272: 258-2516 TILT (LEFT HAND) TILT (RIGHT HAND) I
(5) COUPLING (7) COUPLING 258-2515 258-2514
(20) MOTOR GP AUXILIARY TOOLS
(36) VALVE GP FEMALE 2 MALE 2
HYSTAT 229-5468
SINGLE SELF LEVEL 229-5471
285-2605
246/256/262: 258-2801 (8) COUPLING
CHARGE SUPPLY
DRAIN MANIFOLD - TO TANK TO PILOT SHUTOFF D C 272: 258-2802 MALE 3
I Y
CHARGE SUPPLY
TO PILOT SHUTOFF
Y I 229-5473
R
R

(4) COUPLING (6) COUPLING


FEMALE 1 MALE 1
218-5841 218-5840

H A
H
X A X
PO
(15) MOTOR GP (16) MOTOR GP
2 SPEED (LEFT HAND) 2 SPEED (RIGHT HAND)
246/256/262: 258-2520 246/256/262: 258-2521 1A 1B 2A 2B
272: 258-2835 272: 258-2836 3A 3B 4A 4B
MC EE MB MB
MC EE

C D M3 X7 A B
C D M3 X7 A B

B B
(31) VALVE GP B B
MANUAL BALL
112-1817
G G
(35) VALVE GP
RIDE CONTROL
307-2275
M M H R

(29) VALVE GP
CHECK
E
E
304-6756
(24) PUMP GP
MD CHARGE SUPPLY MA HYSTAT (24) PUMP GP (30) VALVE GP
F FROM HYD FILTER CHARGE SUPPLY F
289-6362 MD FROM HYD FILTER
MA HYSTAT ACC
CHECK
289-6362 314-2403
A A A A
XDP OPTION TWO SPEED OPTION (2) ACCUMULATOR ACC
RIDE CONTROL
307-6504
(37) VALVE GP
CC XPS IMPLEMENT
(1) ACCUMULATOR PILOT 336-1323
IMPLEMENT VALVE CHARGE
193-0447 (34) VALVE GP
(32) VALVE GP
RIDE CONTROL
T PILOT SHUTOFF
ACCUMULATOR
274-8563 (3) COOLER
PRECHARGE
307-2276 (10) CYLINDER GP ASSEMBLY
E P QUICK COUPLER 258-3457 E
192-2640

(14) MANIFOLD AS
(18) MOTOR GP BYPASS CHECK
BETA SINGLE SPEED 308-0421
246/256/262: 258-2442
I 272: 258-2605
R I (33) VALVE GP
L C1 C2 QUICK COUPLER
291-0010
T P

D D

(19) MOTOR GP
DEMAND FAN
258-2577
G
R
L BB
S B
X X

L
(13) FILTER GP
AA OIL
L3 223-9974
MC EE MB B X

C C
C D M3 X7 A B STANDARD FAN MOTOR

HYDRAULIC CIRCUIT COLOR DESCRIPTIONS


IMPLEMENT PUMP CIRCUIT
(17) MOTOR GP PILOT SUPPLY CIRCUIT
CHARGE PUMP CIRCUIT
ATAAC FAN CHARGE PUMP AND ATAAC FAN PUMP CIRCUIT
258-2926 S B SUPPLY LINE
DRAIN / RETURN LINE
B1 B2 STEERING CIRCUIT
TILT CYLINDER CIRCUIT
LOAD SENSE CIRCUIT
LIFT CYLINDER CIRCUIT
AUXILIARY TOOLS CIRCUIT
M CONTROL COUPLING CIRCUIT
QUICK COUPLER CYLINDER CIRCUIT
TRAVEL CONTROL CIRCUIT
TWO SPEED CONTROL VALVE CIRCUIT
B (25) PUMP GP
ATAAC FAN MOTOR B
IMPLEMENT S T S1 S2
LINE PATTERNS
258-2554 Pressure Line
(23) PUMP GP - CHARGE (22) PUMP GP
STANDARD: 258-2555 CHARGE AND ATAAC Pilot / Load Sensing Pressure
EU: 258-3261 STANDARD: 258-3465 Drain / Return Lines
E
EU: 258-3521 Component Group

(26) PUMP GP Attachment


SSL DRIVE (27) TANK GP
258-2831 Air Line
MD MA 258-2404
(21) ORIFICE CALLOUTS
6V-8627 YY Taps (Pressure, Sampling,Sensor) by letter

A A
246C, 256C, 262C, 262C2, AND 272C SKID STEER LOADER HYDRAULIC SYSTEM
STANDARD CONFIGURATION VOLUME 2 of 2: XPS HIGH FLOW
MEDIA NUMBER: KENR5117-05
PART NUMBER: 258-3995, CHANGE: 06, VERSION: -
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.

13 12 11 10 9 8 7 6 5 4 3 2 1
MACHINE COMPONENT LOCATIONS -
STANDARD FLOW
VIEW ALL CALLOUTS

3 4 26 30 17 29 28 31 18 24 13 14 16

11

12

19

10

25 20 23 17 32 2 1 18 28 27 15 21 22

25 32 11 17 3 2 1 29 13 14

23

20

12

10

4 19 26 30 18 28 27 31 24 15 16 21 22
MACHINE COMPONENT LOCATIONS - XPS
VIEW ALL CALLOUTS

17 24 26 27 9 28 2 15 18 8 7 4 5 6 11 10 33

19

29

31

32

13

36

37

35 34 14 9 1 2 22 23 25 2 21 16 18 30 12 10

3 9 17 27 28 12 11 4 5 6 7 8 10 33

19

35

34

36

37

13

29

14
26 24 1 32 31 22 23 25 2 21 30 18 15 16
AIR-TO-AIR AFTERCOOLER SYSTEM
ATAAC (IF EQUIPPED) - STANDARD FLOW

Gear Pump (Hydrostatic System)

Piston Pump (Work Tool)

Gear Pump (Charge Oil)


Gear Pump (Aftercooler)

Relief Valve

Gear Motor (Aftercooler)


AIR-TO-AIR AFTERCOOLER SYSTEM - XPS

Gear Pump
(Hydrostatic System)

Piston Pump
(Work Tool)

Gear Pump
(Charge Oil)

Gear Pump
(Aftercooler)

Relief Valve

Gear Motor
(Aftercooler)
DEMAND FAN MOTOR AND HYDRAULIC
OIL FILTER - STANDARD FLOW
VIEW ALL CALLOUTS

BB 6

Differential pressure Sensor

7
DEMAND FAN MOTOR AND HYDRAULIC
OIL FILTER - XPS HIGH FLOW
VIEW ALL CALLOUTS

BB 19

Differential pressure Sensor

13
IMPLEMENT PUMP AND CHARGE
PUMP - STANDARD FLOW
VIEW ALL CALLOUTS

26

30 1
IMPLEMENT PUMP AND CHARGE PUMP - XPS
VIEW ALL CALLOUTS

24

26

23

25

XPS Pressure
Adjustment

Margin Pressure
Adjustment AA
IMPLEMENT VALVE - (STANDARD)

A B
R
C
Q D
P

E
F
M
N G
L
K H
S
J

(A) Control Valve (work tool) (G) Load check valve for the lift control valve
(B) Solenoid valve for the auxiliary function (H) Outlet
(C) Solenoid valve for the tilt function (J) Inlet
(D) Solenoid valve for the lift function (K) Relief valve - lift cylinder head end.
(E) Load check valve for the auxiliary control valve (L) Relief Valve - tilt cylinder head end.
(F) Load check valve for the tilt control valve (M) Relief Valve - auxiliary valve B port.

(N) Relief Valve for the rod end of the tilt cylinder
(P) Solenoid valve for the lift function
(Q) Solenoid valve for the tilt function
(R) Solenoid valve for the auxiliary function
(S) Main relief valve for the work tool hydraulic system
IMPLEMENT VALVE - (XPS)

A
F
Q B

P C G

O D

N E H
I

(A) Control Valve (work tool)


(B) Solenoid Valve for the auxiliary function (G) Isolator Compensator Assembly for the tilt cylinders
(C) Solenoid Valve for the tilt function (H) Isolator Compensator Assembly for the lift cylinders
(D) Solenoid Valve for the lift function (I) Isolator Compensator Assembly for the secondary
(E) Solenoid Valve for the secondaryauxiliary function auxiliary function
(F) Isolator Compensator Assembly for the auxiliary function (J) Relief Valve for the auxiliary function

J
M
K

(L) Relief Valve for the secondary auxiliary function


(M) Relief Valve for the tilt cylinders
(N) Solenoid Valve for the secondary auxiliary function
(O) Solenoid Valve for the lift function
(P) Solenoid Valve for the tilt function
PISTON MOTORS - STANDARD FLOW
VIEW ALL CALLOUTS

18 27 31 31 28 18

RIGHT LEFT
PISTON MOTORS - XPS
VIEW ALL CALLOUTS

16 18 20 18 15 20

RIGHT LEFT
PISTON PUMP (HYDROSTATIC) - STANDARD
FLOW

D E F G

H
B

C
J
A
K

M L

N P

(A) Rear pump - right hand side drive motor (F) Port E (L) Port A
(B) Rear pump displacement control (G) Reverse solenoid on the Front pump (M) Port D
(C) Forward solenoid on the Rear pump (H) Front pump displacement control (N) Fwd solenoid - Front pump
(D) Port C (J) Front pump - left side drive motor (P) Rev solenoid - Rear pump
(E) Port B (K) Input shaft
PISTON PUMP (HYDROSTATIC) - XPS
VIEW ALL CALLOUTS

D E F G

B
H
C
J

A K

M L

24 26
N P

(A) Rear pump - right hand side drive motor (F) Port E (L) Port A
(B) Rear pump displacement control (G) Reverse solenoid on the Front pump (M) Port D
(C) Forward solenoid on the Rear pump (H) Front pump displacement control (N) Fwd solenoid - Front pump
(D) Port C (J) Front pump - left side drive motor (P) Rev solenoid - Rear pump
(E) Port B (K) Input shaft
PRESSURE TAPS - HYSTAT PUMP
(STANDARD FLOW)
VIEW ALL CALLOUTS
4 26 30 MA MD

EE MB MC

4 26 30 Parking Brake Hose Assembly


PRESSURE TAPS - HYSTAT PUMP (XPS)
VIEW ALL CALLOUTS
24 26 MA MD

EE MB MC

Parking Brake Hose Assembly


24 26
QUICK COUPLER AND COUPLER
CYLINDERS - STANDARD FLOW
VIEW ALL CALLOUTS

21

22
QUICK COUPLER AND COUPLER CYLINDERS
(XPS)
VIEW ALL CALLOUTS

33

10
TANK - STANDARD FLOW

Hydraulic tank
sight gauge
Hydraulic tank 3
filler cap

Oil temperature
sensor

Hydraulic Tank Filler Cap Hydraulic Tank Sight Gauge


TANK - XPS HIGH FLOW

Hydraulic tank
sight gauge
Hydraulic tank 27
filler cap

Oil temperature
sensor

Hydraulic Tank Filler Cap Hydraulic Tank Sight Gauge