Anda di halaman 1dari 6

HW H

CORPORATION
R

HYDRAULIC SCHEMATICS
HWH HYDRAULIC SPACEMAKER
R R

ROOM EXTENSION SYSTEMS

FEATURING:
Universal Level Out

HWH CORPORATION
(On I-80, Exit 267 South)
2096 Moscow Road | Moscow, Iowa 52760
Ph: 800/321-3494 (or) 563/724-3396 | Fax: 563/724-3408
www.hwh.com

ML52894/MP04.9496
08NOV13
HYDRAULIC SCHEMATIC - ULO
ROOM CYLINDERS RETRACTED - LIFT CYLINDERS RETRACTED
ROOM OUT AND DOWN

O - RING 1100 TO 1300 PSI O - RING


ROD (A)
ON ROD SIDE
TO OPEN
A PILOT CHECK

B
CAP (B)
ROOM
CYLINDERS

VALVE A -
ROOM RETRACT
CYLINDERS EXTEND

VALVE B -
ROOM EXTEND
CYLINDERS RETRACT

WHEN ROOM
CYLINDERS ARE CAP END
RETRACTED,
ROOM IS EXTENDED.

WHEN LIFT
CYLINDERS ARE SYNC CYLINDER
RETRACTED,
ROOM IS DOWN. IMPORTANT: WEIGHT OF ROOM CAUSES ROOM
LIFT CYLINDERS TO RETRACT ALLOWING
ROOM TO LOWER.

ROOM LIFT ROOM LIFT


CYLINDER ROOM LIFT CYLINDER
SYNC CYLINDER MP64.9493A
08NOV13
HYDRAULIC SCHEMATIC - ULO
EXTENDING ROOM - ROOM UP AND RETRACTED
ROOM CYLINDERS START TO RETRACT (EXTENDING ROOM)

O - RING 1100 TO 1300 PSI O - RING


ROD (A)
ON ROD SIDE
TO OPEN
A PILOT CHECK

B CAP (B)
ROOM
CYLINDERS

VALVE A -
ROOM RETRACT
CYLINDERS EXTEND

VALVE B -
ROOM EXTEND
CYLINDERS RETRACT

SYMBOL INDICATES CAP END


FLOW OF FLUID

SYMBOL INDICATES
PUMP PRESSURE SYNC CYLINDER
WITH NO FLOW

WHEN LIFT CYLINDERS IMPORTANT: WEIGHT OF ROOM CAN CAUSE


ARE EXTENDED, LIFT CYLINDERS TO RETRACT ALLOWING
ROOM IS UP. ROOM TO LOWER WHILE EXTENDING. FLUID
FLOW FROM CAP END OF ROOM CYLINDERS
AS ROOM IS LOW PRESSURE WHILE ROOM IS EXTENDING.
CYLINDERS
RETRACT, ROOM
EXTENDS.

ROOM LIFT ROOM LIFT


CYLINDER ROOM LIFT CYLINDER
SYNC CYLINDER MP64.9493E
08NOV13
HYDRAULIC SCHEMATIC - ULO
EXTENDING ROOM - ROOM OUT - ROOM STARTS TO LOWER
LIFT CYLINDERS START TO RETRACT (LOWERING ROOM)

O - RING 1100 TO 1300 PSI O - RING


ROD (A)
ON ROD SIDE
TO OPEN
A PILOT CHECK

B CAP (B)
ROOM
CYLINDERS

VALVE A -
ROOM RETRACT
CYLINDERS EXTEND

VALVE B -
ROOM EXTEND
CYLINDERS RETRACT

SYMBOL INDICATES CAP END


FLOW OF FLUID

SYMBOL INDICATES
PUMP PRESSURE SYNC CYLINDER
WITH NO FLOW
IMPORTANT: WEIGHT OF ROOM CAUSES ROOM
WHEN ROOM CYLINDERS LIFT CYLINDERS TO RETRACT ALLOWING
ARE RETRACTED, ROOM TO LOWER.
ROOM IS EXTENDED.

AS LIFT
CYLINDERS
RETRACT, ROOM
LOWERS.

ROOM LIFT ROOM LIFT


CYLINDER ROOM LIFT CYLINDER
SYNC CYLINDER MP64.9493F
08NOV13
HYDRAULIC SCHEMATIC - ULO
RETRACTING ROOM - ROOM OUT - ROOM IS DOWN
LIFT CYLINDERS START TO EXTEND (LIFTING ROOM)

O - RING 1100 TO 1300 PSI O - RING


ROD (A)
ON ROD SIDE
TO OPEN
A PILOT CHECK

B CAP (B)
ROOM
CYLINDERS

VALVE A -
ROOM RETRACT
CYLINDERS EXTEND

VALVE B -
ROOM EXTEND
CYLINDERS RETRACT

SYMBOL INDICATES CAP END


FLOW OF FLUID

SYMBOL INDICATES
PUMP PRESSURE SYNC CYLINDER
WITH NO FLOW

ROOM CYLINDERS SHOULD


NOT MOVE UNTIL LIFT
CYLINDERS ARE FULLY
EXTENDED

WHEN ROOM CYLINDERS


ARE RETRACTED,
ROOM IS EXTENDED.

AS LIFT
CYLINDERS
EXTEND, ROOM
RAISES.

ROOM LIFT ROOM LIFT


CYLINDER ROOM LIFT CYLINDER
SYNC CYLINDER MP64.9493G
08NOV13
HYDRAULIC SCHEMATIC - ULO
RETRACTING ROOM - ROOM UP - ROOM STARTS TO RETRACT
LIFT CYLINDERS EXTENDED (ROOM UP) - ROOM CYLINDERS EXTENDING

O - RING 1100 TO 1300 PSI O - RING


ROD (A)
ON ROD SIDE
TO OPEN
A PILOT CHECK

B CAP (B)
ROOM
CYLINDERS

VALVE A -
ROOM RETRACT
CYLINDERS EXTEND

VALVE B -
ROOM EXTEND
CYLINDERS RETRACT

SYMBOL INDICATES CAP END


FLOW OF FLUID

SYMBOL INDICATES
PUMP PRESSURE SYNC CYLINDER
WITH NO FLOW

ROOM CYLINDERS ROOM CYLINDERS CAN NOT EXTEND


SHOULD NOT MOVE *(ROOM RETRACT) UNTIL THE ROOM LIFT
UNTIL LIFT CYLINDERS SYNC CYLINDER RELIEF VALVE OPENS.
ARE FULLY EXTENDED THE RELIEF VALVE WILL OPEN BETWEEN
2700 AND 2900 PSI.
WHEN LIFT CYLINDERS
ARE EXTENDED, ROOM
IS UP.

AS ROOM
CYLINDERS
EXTEND, ROOM
RETRACTS.
RELIEF
VALVE
*

ROOM LIFT ROOM LIFT


CYLINDER ROOM LIFT CYLINDER
SYNC CYLINDER MP64.9493H
08NOV13

Anda mungkin juga menyukai