Anda di halaman 1dari 1

Type of protection: II 2 G EEx d IIC

Class of temperature: T3
Optical warning Protection degree: IP 65
EVC100X blinking Xenoflash Certificate:
temp. Ambiente
INERIS 03 ATEX 0197X
-20 +40°C
Zones: 1–2

Dimensions (mm) Voltage (V) Power Available Working


Type
A B C (Vdc) (Vac) colours

12 / 24 BL=Blue
12 / 24 48 GI=Yellow
EVC 100 / X… 194 134 108
48 110
25 W NT=Neutral ON ∞
220 / 240 RO=Red
VE=Green

Description: Inhibiting treatments:


The EVC100/X fixture is composed of a central body on Epoxy painting RAL 7000
which a box with fixing flange is mounted, complete with
tempered glass globe, containing a blinking lamp Xenoflash. Application:
To complete the code, please add the figure showing the For optical warning of alarms, damages, etc...
color. (Example: EVC100X.RO)
On request:
Materials: Stainless steel protection guard.
Body: aluminium alloy. Other types of connections on the fixtures..
Globe: tempered glass.

Cables entries:
N°4 entries ∅ 3/4” UNI 6125 (ISO 7/1).

V.le Rimembranze, 93
20099 Sesto S. G. (MI) ITALY ATEX
Tel.: +39-02-2247.7248 ar
NOTIFIED
Fax: +39-02-2421.709
info@adssrl.it www.adssrl.it