Anda di halaman 1dari 1

EHS RISK ASSESSMENT

Ref : HMRP - 08 B Rev 00


Project : Hyderabad Metro Rail
Client : Hyderabad Metro Rail limited
Independent Engineer : Louis Berger Consulting Pvt. ltd
Concessionaire : L&T Metro Rail Hyderabad Limited
Contractor : L&T Construction PT&D IC (POWER SUPPLY & SCADA PROJECT)

Activity considered : Backfilling Date: 05.09.12

Severity rating
Hazard / Environment Aspect

Probability
Risk / Residual

rating
Sl.no Activity Existing control measures Imapct Additional Control measures Risk / Action by
Source / Situation /
Possible outcome People at risk level Impact
Act

1) Ensuring pathway clear 2)


1) Undulations of the Ensuring existence of any power
earth 1) Fall of machinery lines & take LC if applicable 1) No workmen shall undertake
2) Obstruction by 2) Electrocution Vehicle 3) Vehicle having all basic safety rest beneath the vehicle
Approach to the
1 existing power lines 3) Injury to workmen operator & requirements(reverse horn, 4 5 High 2) Deploying a signal man for Low Supervisor
work area
3) Roll over person 4) Struck of the helper warning signals, guards etc) supervising the vehicle (forward,
4) Loaded vehicle / loaded vehicle 4) Authorize operator with obeying reverse etc)
dumper to all statutory documents & also
PUC certificate.

1) Noise / smoke shall be within


1) Hit by machinery 1) Injury to workmen Vehicle 1) Operator / workmen shall be
acceptable limits (ambient
2) Expel of dust 2) Respiratory operator, provided with nose mask,ear plug
Backfilling of the monitoring systems) Site Engineer
2 3) Noise diseases helper & etc 2) 4 4 High Low
pit 2) Helper shall be engaged for / Supervisor
4) Mis- 3) Ear damage workmen NO person shall stand in the swing
guiding adverse movements of the
communication 4) Eye irritation working around area of the machine
vehicle

FOR LTC FOR LTMRHL

Anda mungkin juga menyukai