The purpose of this bulletin is to inform the field of a The new main bearing K-Type thermocouple individual
new main bearing thermocouple harness upgrade kit upgrade kit (P/N G-962-1170) replaces main bearing
and a new main bearing K-Type thermocouple individual thermocouple P/N 208426D on the previous
individual upgrade kit that offer improved vibration- production main bearing harness (P/N 214037D). See
resistance and reliability. Table 2 for the kit components.
Symptoms indicating an upgrade should be performed Table 2: Components of Main Bearing K-Type
include: Thermocouple Individual Upgrade Kit (G-962-1170)
• Repeated engine shutdowns due to high main P/N DESCRIPTION QTY
bearing temperature 208426K K-Type Thermocouple 1
• Erratic main bearing temperature readings 214693 New Connector 1
• Connector Body 1
• Excessive replacement of main bearing
thermocouples due to failure • Wedge 1
• Mounting Clip 1
• Main bearing thermocouple connectors coming
• Pin 2
loose from harness connectors
The new main bearing thermocouple harness upgrade See Table 3 for the quantity of main bearing
kit (P/N G-962-1126) replaces main bearing harness thermocouples on each engine type.
P/N 214037D. See Table 1 for the kit components.
Table 3: Quantity of Main Bearing Thermocouples
Table 1: Components of Main Bearing Thermocouple
Harness Upgrade Kit (P/N G-962-1126) QUANTITY OF
VHP
THERMOCOUPLES
P/N DESCRIPTION QTY 6-cylinder engine 7
Main Bearing Thermocouple 12-cylinder engine 7
741077 1
Harness 16-cylinder engine 10
208426K K-Type Thermocouple 7

* Trademark of General Electric Company


All other trademarks are the property of their respective owners.

8/8/2017
Copyright © 2017, General Electric Co. Page 1 of 2
Service Bulletin No. 1-4081

When replacing individual K-Type thermocouples on Pull the cable through the oil pan until the stop collar
the previous production main bearing thermocouple (see Figure 2) engages, with the ferrule, which allows
harness P/N 214037D, remove and discard the for uniform tension in all thermocouple cables and
original quick disconnect (see Figure 1). prevents stress on the cable. Install the male end of
the thermocouple connector to the connector body.
3 4
2
1
3
1

2
Figure 1: Original Quick Disconnect
Figure 2: New Main Bearing K-Type Thermocouple
1 - Negative Conductor 4 - Retaining Screws
(Red) 5 - Quick Disconnect 1 - Connector Body 3 - Thermocouple
2 - Insulation Jacket Plug (Female End) 2 - Ferrule Connector Male End
3 - Positive Conductor 6 - Stainless-Steel Braid
(Yellow)

Use the new connector body, wedge, mounting clip


and pins provided in the new main bearing K-Type
thermocouple individual upgrade kit (G-962-1170).
Use the crimping tool (P/N 495830) to secure the pins
on the previous production harness P/N 214037D
wiring. The new thermocouple P/N 208426K can
be used with the previous production harness
P/N 214037D.