and for reducing or eliminating the stops for replenishment. These installations are
destined to assure the preservation of outage aliments by cold for the crew’s and passagers
food.
In the first part of the work generalties about maritime transportation are presented,
specifically the role and the place it has in the actual trade and the main problems that it
confronts. After, a short presentations of the cargo ship it has been made, including it’s
constructive data, as well, the stipulations of clasification societies tied up on the frigorific
installation aboard and it’s main components.
The main part of this works includes terms about obtaining the low temperatures and the
presentation of the frigorific installation, with it’s schematic presentation, the description
and it’s functioning. Also, in this part the compressor chosen depending on the amount of
cold for the ship’s compartments is presented, also with it’s dimenssioning according with
the compartment’s requirements.
In the final part the installation’s automation is presented, as well it’s exploatation and it’s
mentenance.
The ship has 5 frigorific compartments and the frigorific installation has to cover all it’s
cold necessity. A calculus has been made to determine the exact amount of cold and a 17,3
kW power for the installation was obtained. Depending on this power of the frigorific
compressor was dimensioned, resulting the fact that the insallation requires two
compressors, each with a 8,66 power.
The installation aboard the ship is a mechanical one, in a single step with a 17,3 kW total
power, wich can assure the cold necessary in the specified compartments, thus the outage
products can be transported in the best conditions
Nava este dotată cu 5 compartimente frigorifice, iar instalatia frigorifică a navei trebuie să
acopere necesarul de frig pentru aceste compartimente.Am efectuat calculul pentru aflarea
necesarului de frig si am obtinut o putere pentru instalatie de 17,3 kw.În functie de această
putere am dimensionat compresorul frigorific, rezultând faptul ca instalatia are nevoie de 2
compresoare tip K 902 care au o putere de 8,66 kw fiecare.
Instalația de la bordul navei este una cu comprimare mecanică intr-o treapta cu o putere de
17,3 Kw ce poate asigura necesarul de frig in compartimentele specificate in asa fel încat
produsele perisabile sa poata fii transportate in cele mai bune conditii.
1. NOTIUNI GENERALE
d) etc.
In figura de mai jos sunt reprezentate partile componente si circuitul celei mai
simple instalatii frigorifice:
Compresorul C, absoarbe vaporii reci formati in vaporizatorul V, a caror stare
este caracterizata de punctul a. Vaporii sunt comprimati adiabatic (fara schimb de
caldura) in compresor, marindu-le presiunea si implicit temperatura pina la starea din
punctul b, de vapori saturati uscati.
3. INSTALATII FRIGORIFICE
In figura de mai sus s-a reprezentat cea mai simpla instalatie frigorifica cu
compresor intr-o singura teapta de comprimare, utilizata in cazul instalatiilor cu puteri
frigorifice mici, sub 5 000 kcal daN/h.
Redam mai jos schema unei instalatii frigorifice cu doua trepte de comprimare
(in schema s-a figurat un singur vaporizator):
Vaporii formati in vaporizatoarele 7, dupa ce trec printr-un separator de lichid
6 sunt aspirati de compresorul 1 (de joasa presiune cu 2 cilindri).
1 - stare linistita;
2 - efort redus;
3 - efort mediu;
4 - efort mare;
- fata de debitul total de aer G1, debitul de aer exterior trebuie sa fie minim 0,7
G1 pentru incaperile de locuit si 0,5 G1 pentru cele de serviciu, daca
amestecarea cu aerul de recirculatie se produce in exteriorul incaperii; daca
acest amestec se realizeaza in interiorul incaperii deservite, debitul de aer
exterior poate fi redus pana la 0,3 G1.
1 - traductor termic;
2 - filtru;
5 - ventilator;
6 - racord cu fonoatenuator;
9 - umidificator;
10 - tubulatura perforata de alimentare cu abur pentru umidificarea
aerului;
12 - armatura electromagnetica;
13 - panou electric;
15 - traductor de umiditate;
Raportul dintre cantitatea de aer aspirata din incapere si cantitatea de aer cald
introdus in tubulatura se numeste coeficient de ejectie.
Ga = GI + GII = const.
In figura de mai jos sunt reprezentate schematic doa amestecatoare de aer cu
doua circuite.
3 - piston crenelat;
4 - tija pistonului;
5 - pirghie de echilibrare;
6 - sector dintat;
7 - pinion de actionare;
8 - ajutaj ejector;
9 - gratar de ejectie;
10 - gratar de refulare;
11 - miner de reglare;
12 - cremaliera.
Ga = GI + GII = const.
La executarea instalatiilor de conditionare a aerului trebuie respectate normele
impuse de societatile de clasificare:
- nu este permisa trecerea canalelor de aer prin peretii etansi pe sub puntea
peretilor etansi;
- canalele de aer care trec prin peretii principali rezistenti la foc trebuie sa fie
dotate cu clapete impotriva propagarii incendiilor, executate din otel si
montate pe peretii etansi sau pe peretii principali rezistenti la incendiu;
clapetele trebuie sa fie prevazute cu dispozitive de inchidere si cu
indicatoare de pozitie, iar la navele pasagere inchiderea lor trebuie sa fie
automata;
- gurile de aspiratie ale instalatiei de ventilatie naturala sau fortata trebuie sa fie
amplasate in locuri in care este redusa la minimum posibilitatea patrunderii
apei de mare sau a aerului poluat cu gaze sau vapori ai produselor petroliere;
5. INSTALATIA DE CAMBUZA.
5.1. GENERALITATI.
Compartiment Temperatura °C
carne - 15
peste - 15
vegetale + 2
produse uscate + 12
antecamera + 6
de reglaj;
de control;
de protectie automata.
termostatele de camera;
ventilele electromagnetice;
vizoare de lichid;
manometre si manovacumetre.
Termometre cu citire la distanta sunt montate pentru fiecare compartiment
in anticamera sau culoar si dau posibilitatea citirii in orice moment a
temperaturii realizate.
presostat diferential.
5.4.1.Functionarea normala.
5.4.3.Decongelarea.
FRIGORIFICE CU FREON.
Folosirea otelului inoxidabil sau a nichelului este preferata dar este foarte
costisitoare.
Este interzisa folosirea in contact cu freonii a aliajelor de magneziu, zinc,
a otelului galvanizat si a aluminiului continind mai mult de 2% magneziu.
2. Montajul condensatoarelor.
FRIGORIFICE DE CAMBUZA
1. Terminologie.
1.Inclinari:
tangaj ± 7,5°;
2.Temperaturi:
3.Vibratii.
- amplitudinea de ±1 mm;
4..Zgomot:
R-12 CF Cl 1,2
I R-22 CHF Cl 2
R-22+R115 amestec.azeotrop 2
II R-117 Amoniac 2
III R-290 Propan 1,6
R-
1270 Propilen 2
Ca pompa de rezerva se poate folosi orice pompa navala pentru apa din
afara bordului, avind presiune si debit suficient.
Apa de racire trebuie sa fie alimentata de la cel putin doua prize de fund.
3. Materiale.
5. Mecanisme.
Racitoare de aer.
6. Tubulaturi.
Izolatia tubulaturilor.
Pentru evitarea formarii puntilor termice, tubulaturile care trec prin pereti
sau punti vor fi izolate de contactul direct cu partile metalice ale corpului navei.
Izolatia tubulaturilor trebuie protejata de umezeala.
8. Piese de rezerva.