Anda di halaman 1dari 5

Totally Integrated

Automation Portal

examen / PLC_2 [CPU 314C-2 PN/DP] / Bloques de programa


Main [OB1]
Main Propiedades
General
Nombre Main Número 1 Tipo OB
Idioma KOP Numeración automática
Información
Título "Main Program Sweep Autor Comentario
(Cycle)"
Familia Versión 0.1 ID personaliza‐
da

Main
Nombre Tipo de datos Valor predet.
Temp
OB1_EV_CLASS Byte
OB1_SCAN_1 Byte
OB1_PRIORITY Byte
OB1_OB_NUMBR Byte
OB1_RESERVED_1 Byte
OB1_RESERVED_2 Byte
OB1_PREV_CYCLE Int
OB1_MIN_CYCLE Int
OB1_MAX_CYCLE Int
OB1_DATE_TIME Date_And_Time
Constant

Segmento 1:

Segmento 1:

CONV MUL
Int to DInt DInt
EN ENO EN ENO 1
%IW64 %MD12 %MD12 %MD16
"WT1" IN OUT "Tag_2" "Tag_2" IN1 OUT "Tag_3"
5000 IN2

DIV
DInt
1 EN ENO
%MD16 %MD20
"Tag_3" IN1 OUT "Tag_4"
27648 IN2

Segmento 2:
Totally Integrated
Automation Portal

Segmento 2:

CONV MUL
Int to DInt DInt
EN ENO EN ENO 1
%IW66 %MD24 %MD24 %MD28
"WT2" IN OUT "Tag_5" "Tag_5" IN1 OUT "Tag_6"
6000 IN2

DIV
DInt
1 EN ENO
%MD28 %MD32
"Tag_6" IN1 OUT "Tag_7"
27648 IN2

Segmento 3:

%MD20 %MD32 %I0.0 %I0.7


"Tag_4" "Tag_7" "START" "S2" MOVE
<= <=
EN ENO
DInt DInt
50 50 1 IN %MB0
OUT1 "Tag_9"

Segmento 4:

%M0.0 %M40.0 %I0.7 %M40.0 %Q0.0


"ON" "Tag_18" "S2" "Tag_18" "MES"
S

%M1.0 %Q0.1
"Tag_14" "GH_UP"

Segmento 5:
Totally Integrated
Automation Portal

%DB1
"T1"
%M0.0 %I0.6 TON %M0.4
"ON" "S1" Time "Tag_10"
IN Q
T#6S PT ET ...

%DB1.DBD8 %M1.0 %Q0.6


"T1".ET
"Tag_14" "C2"
>=
S
Time
T#5S
%Q0.4
"G2"

MOVE
EN ENO
1 IN %MB40
OUT1 "Tag_17"
%Q0.1
"GH_UP"
R

Segmento 6:

%M0.0 %M1.0 %DB1.DBD8 %Q0.5


"ON" "Tag_14" "T1".ET "C1"
>=
S
Time
T#5S
%Q0.3
"G1"

MOVE
EN ENO
1 IN %MB40
OUT1 "Tag_17"

Segmento 7:
Totally Integrated
Automation Portal

%M0.0 %MD32 %Q0.2


"ON" "Tag_7" "GH_DOWN"
>
S
DInt
1000
%I0.7 %Q0.2
"S2" "GH_DOWN"
R
%MD20
"Tag_4"
%Q0.0
>
"MES"
DInt
3500 R

Segmento 8:

%DB3
"T3"
%M0.0 %Q0.2 TOF
"ON" "GH_DOWN" Time
IN Q
T#11S PT ET ...

Segmento 9:

%DB3.DBD8 %Q0.6
"T3".ET "C2"
>=
R
Time
T#10S
%Q0.2
"GH_DOWN"
R

%M1.0
"Tag_14"
S

%Q0.5
"C1"
R
MOVE
EN ENO
0 IN %MB40
OUT1 "Tag_17"

Segmento 10:
Totally Integrated
Automation Portal

%I0.2
"RESET" MOVE
EN ENO
0 IN %QB0
OUT1 "Tag_8"

MOVE
EN ENO
0 IN %MB0
OUT1 "Tag_9"

MOVE
EN ENO
0 IN %MB40
OUT1 "Tag_17"