𝑞2 𝑞2
𝑞1
1m 26 m 1m
28 m
𝑄1 𝑄2
19.25 Tn
9.40 Tn
+ 9.40 Tn
-
19.25 Tn
L/4=7.0 m 7.0 m 7.0 m 7.0 m
L/2=15 m
+ +
Según AASHTO en su art 1.5.23 (J) especifica que los diafragmas deben ser
ubicados a distancia no mayores a 40 pies = 12 m; además sus dimensiones
serán:
8m
hdiaf
hviga
ℎ𝑑𝑖𝑎𝑓 = 1.1 𝑚
q = 652.38 Kg/m
𝑞𝐿
𝑄1 = 𝑄2 =
2
7.0 m 7.0 m 7.0 m 7.0 m 𝑄1 = 9785.7 𝐾𝑔
𝑄1
9.79 Tn 𝑄2
4.9 Tn
+
𝑀𝐿/4 = (9785.7 ∗ 7.5) − (652.38
- ∗ 7.5 ∗ 3.75)
4.9 Tn
9.79 Tn
𝑀𝐿/4 = 55044.56 𝐾𝑔. 𝑚
55.04 Tn.m Mmax = 73.39 Tn. m 55.04 Tn.m
𝑀𝐿/4 = 55.04 𝑇𝑛. 𝑚
+ +
𝑞𝐿2 (652.38)(30)2
𝑀𝐿/2 = =
8 8
𝑀𝐿/2 = 73.39 𝑇𝑛. 𝑚
b) Diafragma
(0.20)(1.1𝑚)(5.91𝑚)(2500𝐾𝑔/𝑚3 )
𝑃=
4 𝑣𝑖𝑔𝑎𝑠
𝑃 = 812.625 𝐾𝑔
2𝑃
𝑄1 = 𝑄2 = → 𝑄1 = 812.625 𝐾𝑔
2
𝑀𝐿/3 = (812.625 𝐾𝑔)(7.5 𝑚) = 6094.69 𝐾𝑔. 𝑚
𝑃 · 𝐿 (812.625)(28)
𝑀𝐿/2 = = = 8126.25 𝐾𝑔. 𝑚
3 3
𝑀𝐿/2 = 8.13 𝑇𝑛. 𝑚
P = 812.63 Kg P = 812.63 Kg
Q1 9.33 m Q2
9.33 m 9.33 m
0.76 Tn
+ 0.76 Tn
-
Mmax = 8.13 Tn. m
+
L = 28 m
Según el artc 1.3.1 (b) de la norma AASHTO considera el peso propio de los
protectores, aceras, bordillo y rodadura, como uniformemente distribuido igualmente
en todas las vigas, siempre y cuando estos elementos sean colocados, después del
curado de la losa tablero.
𝑞𝑀 =0.347Tn/m
𝑞𝐿
𝑄1 = 𝑄2 =
2
7.0 m 7.0 m 7.0 m 7.0 m 𝑄1 = 𝑄2 = 4858 𝐾𝑔
𝑄1
4.86Tn 𝑄2 𝑀𝐿/4 = (4858 𝐾𝑔)(7)
2.43 Tn
+
−(347)(7)(5.25)
-
2.43 Tn 𝑀𝐿/4 = 21253.75 𝐾𝑔. 𝑚
4.86 Tn
𝑀𝐿/4 = 21.254 𝑇𝑛. 𝑚
+ + 𝑞𝐿2 347(28)2
𝑀𝐿/2 = =
M =21.25 Tn.m M =21.25 Tn.m 8 8
Mmax = 34.006Tn. m
𝑀𝐿/2 = 34006 𝐾𝑔. 𝑚
L = 28 m
_ La carga viva del proyecto es el camión HS20 (Norma AASHTO), que será
determinado mediante los métodos de Tren Tipo y la Carga Equivalente, escogiendo
el mayor valor que se calcule con ambos métodos.
14`=4.30 m 14`=4.30 m
0.60 1.80 0.60
P/4 P P
3.00 m
Tren Tipo
Ancho de faja
10`
Coeficiente de distribución del momento flector por carga viva para viga
interior
𝐸𝑣𝑖𝑔𝑎
𝐾𝑔 = 𝑛[𝐼 + 𝐴. 𝑒𝑔2 ] 𝑛= =1
𝐸𝑙𝑜𝑠𝑎
Área de la Sección
𝐴 = [(100)(15) + (30)(8) + (40)(8) + (10)(10) + (157)(20) + (25)(25) + (70)(20)]
t = 0.14 m
.1 m
𝑌𝑠𝑐 = 90.88 𝑐𝑚
𝑌´𝑠𝑐 = 76.88𝑐𝑚 𝑐𝑚
h=2m
𝑌𝑖𝑐 = 123.12 𝑐𝑚
0.70 m
𝑑𝑒
𝑚𝑔𝑒 = 𝑒 ∗ 𝑚𝑔𝑖 𝑑𝑜𝑛𝑑𝑒 ∶ 𝑒 = 0.77 + 𝑒 = 𝑓𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑐𝑜𝑟𝑟𝑒𝑐𝑐𝑖𝑜𝑛
2800
de= distancia entre el eje de la viga externa hasta el borde interior del bordillo mm
𝑑𝑒 = 0.7 𝑚 = 700 𝑚𝑚
300 𝑚𝑚 ≤ 𝑑𝑒 ≤ 1700 𝑚𝑚
700 𝑚𝑚
𝑒 = 0.77 + = 𝑒 = 1.02
2800
Factor de impacto
𝐼𝑀 0.33
𝐹𝐼 = (1 + ) = (1 + ) = 𝐹𝐼 = 1.33 𝐼𝑀 = 33
100 100
𝑥(𝐿 − 𝑥)
𝑛2 =
𝐿
19.285(40 − 19.285)
𝑛2 =
40
𝑛2 = 9.98
𝑛1 9.98
=
15.985 19.285
𝑛1 = 8.27
𝑛3 9.98
=
16.415 20.715
𝑛3 = 7.91
𝑃
M= 8.27 + 2P ∗ 9.98 + 2P ∗ 7.91
2
𝑀 = 39.915 𝑃 = 𝟐𝟗𝟓𝟏𝟔𝟒. 𝟎𝟑 𝑲𝒈 ∗ 𝒎
𝑃𝐿 40
𝑛1 = = → 𝒏𝟏 = 𝟏𝟎
4 4
40 ∗ 10
𝑀𝑐𝑣 = 952 ( )
2
𝑀𝑐𝑣(𝑐𝑎𝑚𝑖𝑜𝑛 + 𝑐𝑎𝑟𝑟𝑖𝑙) = 𝑚𝑔𝑖 (𝑀𝑐𝑣 𝑐𝑎𝑚𝑖𝑜𝑛 + 𝑐𝑎𝑟𝑟𝑖𝑙) = 0.61 ∗ 485564.03 = 296194.05 𝑘𝑔𝑚
1
𝑀𝐶𝑉+𝐼 = (355610.57 𝑘𝑔𝑚) → 𝑴𝑪𝑽+𝑰 = 𝟓𝟖𝟐. 𝟗𝟕 𝒕𝒏𝒎
0.61
𝑃
Para sección con excentricidad variable : 𝑅 = 𝑃𝑒 = 0.80 𝑛 = (1 − 𝑅)
𝑖
𝑀𝑚𝑎𝑥 99204000
∗ 𝑃𝑒 = = → 𝑃𝑒 = 940411.4 𝐾𝑔 Sin en el diseño 𝑓𝑡𝑠 = 𝑓𝑡𝑖 = 0
𝐾𝑠 + 𝑒 (53.83 + 51.66)
𝑃𝑒
Asumimos 20 % perdidas del presfuerzo n =20% 𝑅 = = 0.80 𝑛 = (1 − 𝑅)
𝑃𝑖
𝑃𝑒 663284.59
∗ 𝑃𝑖 = = → 𝑃𝑖 = 829105.73 𝐾𝑔
0.80 0.80
𝑒𝑚𝑖𝑛 = 77.93 𝑐𝑚
𝑒𝑚𝑎𝑥 = 108.95 𝑐𝑚
𝑃𝑒 663284.59 𝐾𝑔
𝐴𝑠𝑛𝑒𝑐𝑒𝑠𝑎𝑟𝑖𝑜 = = 2
= 49.90 𝑐𝑚2
𝑓𝑝𝑠 𝑎𝑑𝑚 13290 𝐾𝑔/𝑐𝑚
Para el proyecto se selecciona: Cable estabilizado de 12 torones (12 V ½”)
𝑓𝑝𝑠 𝑎𝑑𝑚 = 0.70 𝑓𝑝𝑢 = 0.70(18986 𝐾𝑔/𝑐𝑚2 ) → 𝑓𝑝𝑠 𝑎𝑑𝑚 = 13290 𝐾𝑔/𝑐𝑚2
49.90
𝑁º𝑐𝑎𝑏𝑙𝑒𝑠 = = 4.21 ≈ 5 𝑐𝑎𝑏𝑙𝑒𝑠
11.84