f = 0.75 9.3.2.3
Vu = qs B ( L/2 - a/2 - d428.2
) = KN
fVn = f 0.17 f ' c B d =822.3 KN > Vu ….. safe Eq. (11-3)
Vu = qs L ( B/2 - b/2 - d490.2
) = KN
fVn = f 0.17 f ' c L d = 941.5 KN > Vu ….. safe Eq. (11-3)
Check of two way action
bo = 2 (a + b + 2d4.67 m
β = a / b 2.00
αs = 40 interior column
0.17 (1 +2/β) = 0.34 Eq. (11-31)
fVn
bo d
[
= the minimum of 0.083 (αs d / bo) +=2 0.3 (governs)
0.33 = 0.33
Eq. (11-32)
Eq. (11-33)
f 'c
Vu = qs (LB - (a + d) (b + d1447.2 KN
fVn = f * 0.3 f ' c bo d =1945.7 KN > Vu ….. safe
Determination of footing reinforcement
Long direction
Mu = qs B ( L - a )² /8440.6
= KN.m. 15.4.2
Mu
Rn = = 0.8122
f B d²
0.85 f'c
rreq =
fy [ 1 1
2 Rn
0 .85 f ' c
] = 0.002
As = r B d =2595.8 mm²
Use 23 Ø12 (As = ###
Bars spacing =### < 450 mm…...safe 10.5.4
Short direction
Mu = qs L ( B - b )² /8504.5
= KN.m. 15.4.2
Mu
Rn = = 0.8609
f L d²
0.85 f'c
rreq =
fy [ 1 1
2 Rn
0 .85 f ' c ]
= 0.0021
fy ψt ψe ψs
Ld = [ *
1.1 λ f ' c (Cb + Ktr)/db
] db Eq. (12-1)
fPnb =11050.0 KN
Bearing strengrh of column
In footing
f 'c
Ldc = 0.24 fy / λ f ' cdb = 405.7 mm (governs) 12.3.2
Ldc minmum = 0.043 fy d325.1 b = mm
L req = Kr Ldc = 398.8 mm 12.3.3 ( a )
Lavailable = h - Cc - ØL - ØS - Ødowel 388.0
= mm Unsafe
In column
dowels compression splice
0 Ls = 0.071 fy db =536.8 mm > 300mm……… safe 12.16.1
1 Ls = (0.13 fy - 24 ) db550.8
= mm > 300mm……… safe
0 Ls = 1.33Ls 713.9 mm 12.16.1
column bars development
Ldc = 0.24 fy / λ f ' cdb = 495.9 mm (governs) 12.3.2
Ldc minmum = 0.043 fy d397.3 b = mm
L req = the larger of dowels splice and column bars development
713.9 mm=
FINAL RESULTS
Dimensions Reinforcement
L (m) B (m) h (m) Long steel Short steel
3.95 m 3.45 m 0.50 m 23 Ø12 26 Ø12