Anda di halaman 1dari 4

abecote sf 217

High chemical-resistant clear resin system

DESCRIPTION A practical
PROPERTIES OF WET MATERIAL
spread rate
abecote sf 217 is a two-component, Spread rate would be
Relative Density 1,2
solvent-free novolac modified epoxy. approximately
2
Light amber 6m / per coat
USES NOTE : the use
of stir-in paste 2 minimum and
Colour Recommended
abecote sf 217 clear resin system is pigments will 3 for adverse
number of coats
used for sealing, laminating, screeding compromise conditions.
and grouting applications. Not suitable chemical Where film
for use on galvanised or other zinc resistance build is required
coated surfaces. a non-woven
For coating metallic surfaces, refer to Flash point +120º C
chemical
the use of abecote 369. Store under resistant mat or
Storage coverage cover in cool tissue is
FEATURES & BENEFITS Film build
conditions generally used
(e.g. a 25 gsm
• High chemical resistance not possible Dilution Do not dilute mass results in
with standard epoxies. resin uptake of
• May be used as a laminating resin. approximately
• For high chemical resistance PROPERTIES DURING APPLICATION 250 ml/m )
2

screeding.
• For chemical tile grouting. Brush or mohair Filled system
• For sealing porous elements such as Application by roller for unfilled
systems. Typical film thickness 6 – 10mm
concrete and wood.
s
Application Spread rate film 1 l/m yields
COLOUR temperature range + 10º C to thickness 1 mm
+ 40ºC
Light amber - do not use pigments. CHEMICAL PROPERTIES
Approximately OF DRY FILM
SURFACE PREPARATION Work life 50 minutes @ See last 3 pages of this data sheet.
25º C
All surfaces must be clean, sound and
dry. Volume solids 100%
The substrate must be dry before PROPERTIES OF CURED MATERIAL
Touch dry –
application Chemical
4 hrs
Electronic moisture content tests must resistance best
Practical cure –
be conducted prior to application of the Curing time @ 25º C at ambient and
24 hrs
priming system. Maximum moisture 4- dramatically
Full cure – Maximum service
5% max. (eg Protimeter Survey Master reduced at
7 days temperature
or equivalent) higher
or Unfilled system temperatures
Dynamic Calcium Chloride moisture (see charts on
“weight gain” over 24 hours Approximately
next pages)
or Max wft 75µm on a non-
(a practical overnight “plastic sheet test” porous surface Shrinkage during
Negligible
is also advisable approx. 1m² masked cure
Coverage on
down on surface) Theoretical coverage concrete varies
for above dft according to MIXING
BONDING / PRIMING porosity
Add the entire contents of the activator
abecote 369 for metal surfaces. tin to the base and, without splashing,
stir with a flat paddle until
homogeneous. This takes at least five
minutes.

Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384
Beware high summer temperature and to give a feather edge over at least a 50 clothing, gloves, eye protection and
overfast drill mixing causing extremely mm width. Prime this feather edge respiratory protective equipment should
fast curing. before laying adjacent material. be worn. The use of barrier creams
Very low winter temperature provides additional skin protection. If
retards/stops curing. CLEANING contact with skin occurs, wash with
water and soap. Splashes into eyes
COVERAGE abe super brush cleaner before should be washed immediately with
dried/cured. plenty of clean water and medical
See last page of this data sheet. advice sought.
PROTECTION ON COMPLETION
APPLICATION Cured abecote sf 217 is inert and non-
Protect against traffic and spillage until toxic but must not be allowed to come
For laminating and sealing cured. Most epoxies chalk and degrade into contact with foodstuff or drinking
in extensive sunlight. water.
applications:
Apply abecote sf 217 by brush or short-
NB: When transporting liquids and
fiber roller. Overcoating times must be MODEL SPECIFICATION semi-liquids by aircraft, ask for material
strictly adhered to. Final cure time,
safety data sheet.
particularly in immersion situations, Two-component, solvent free high
must also be adhered to. abecote sf chemical resistant clear resin
217 must not be applied if the ambient IMPORTANT NOTE
system.
temperature is below 5º C. The curing
reaction will not proceed at low This data sheet is issued as a guide to
The system will be abecote sf 217,
temperatures. solvent-free, high chemical resistant, the use of the product(s) concerned.
Whilst abe Construction Chemicals
clear resin applied in accordance with
For screeding and grouting endeavours to ensure that any advice,
abe Construction Chemicals'
applications: recommendations including necessary recommendation, specification or
Premix the aggregate to obtain even information is accurate and correct, the
fillers as directed.
distribution of the various fractions. company cannot - because abe has no
When using a mechanical mixer, place direct or continuous control over where
PACKAGING and how abe products are applied -
mixed liquid in the pan and slowly add
the premixed aggregate, mixing until an accept any liability either directly or
abecote sf 217 is supplied in 5 litre kits. indirectly arising from the use of abe
evenly coated wetted mix results.
Use this procedure also if manual products, whether or not in accordance
mixing is carried out in a drum. All HANDLING & STORAGE with any advice, specification,
lumps must be broken down and an recommendation, or information given
even, wetted mass obtained. Apply by All abecote sf 217 related products by the company.
means of a pointing trowel to tiles, have a shelf life of 12 months if kept in a
remove excess and ensure that surface dry, cool store in the original, unopened FURTHER INFORMATION
is tooled to compact. packs.
When screeding, lay using plastic If stored at high temperatures and/or Where other products are to be used in
trowels and screed rails of the high humidity conditions, the shelf life conjunction with this material, the
appropriate thickness. Rails should be may be reduced. relevant technical data sheets should be
kept as clean as possible otherwise consulted to determine total
false thicknesses will result. Small HEALTH & SAFETY requirements. abe Construction
areas should be laid at a time trowelled Chemicals has a wealth of technical
to a smooth surface and not touched Wet abecote sf 217 is toxic. Ensure the and practical experience built up over
again. working area is well ventilated during years in the company’s pursuit of
Always try to achieve a wet joint where application and curing excellence in building and construction
one area abuts another. Where it is Avoid inhalation of dust and contact with technology.
known that an edge is going to form an skin and eyes. Suitable protective
overnight joint, this should be trowelled

Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384
Chemical resistance of screeding / grout compound - abecote sf 217

Compressive
strengths /
Chemical Temperature retention Class
Reference 25° C 52 MPa / NA NA
De-ionised water 25° C 37 MPa / 71% R
Mineral acids
30% HCI (Hydrochloric) 25° C 52 MPa / 100% R
30% HCI (Hydrochloric) 25° C 47 MPa / 91% LR
38% H SO ((Sulphuric)
2 4 25° C 51 MPa / 90% R
38% H SO ((Sulphuric)
2 4 25° C 27 MPa / 52% LR
70% H SO ((Sulphuric)
2 4 25° C 49 MPa / 94% R
98% H SO ((Sulphuric)
2 4 25° C 52 MPa / 100% R
98% H SO ((Sulphuric)
2 4 25° C 24 MPa / 47% LR
25% H SO ((Sulphuric)
2 4 Draper Penhall 42 MPa / 82% R
Cycle
98% H SO ((Sulphuric)
2 4 (7 days @ 60° C - NR
+ 7 days RT) x 2
93% HNO (Nitric) 25° C - NR
93% HNO (Nitric) 42° C - NR
30% HNO (Nitric) Draper Penhall - NR
Cycle
Equal amounts of - NR
30% HCI / 38% H SO / 93% HNO
2 4 3
25° C
Equal amounts of - NR
30% HCI / 38% H SO / 93% HNO
2 4 3
42° C
56% H PO (Phosphoric)
3 4 25° C 47 MPa / 91% R
56% H PO (Phosphoric)
3 4 88° C - NR
80% H PO (Phosphoric)
3 4 25° C 49 MPa / 94% R
80% H PO (Phosphoric)
3 4 Draper Penhall - NR
Cycle

KEY - * Based on Reference


R - Resistant (subject to a reasonable standard of housekeeping).
LR - Limited Resistance i.e. occasional spillage provided it is quickly washed down or rapidly evaporated.
NR - Not Resistant.
The classification ‘Resistant’ has been given where samples have retained more than 70% of their compressive strength and have not
lost or gained more than 3% of their weight when totally immersed in the environments. Experience has shown that this interpretation
correlates well with practical applications. As a result the above table has been compiled as a guide to the suitability of correctly applied
screeding material provided that a reasonable standard of housekeeping is maintained during service. End users should satisfy
themselves that the screeding material is suitable for their particular environmental conditions and take into account the mechanical duty
which may accompany any chemical spillage. It should also be noted that some environments (especially inorganic chemicals) will affect
the colour of the screeding material on the surface.

Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384
Chemical resistance of screeding / grout compound - abecote sf 217
Compressive
strengths /
Chemical Temperature retention Class
Organic acids
10% Lactic acid 25° C 46 MPa / 89% R
10% Acetic acid 25° C 37 MPa / 71% R
Solvents
Methanol 25° C 22 MPa / 43% LR
Ethanol 25° C 42 MPa / 80% R
Toluol 25° C 51 MPa / 99% R
Xylene 25° C 52 MPa / 100% R
MEK 25° C 15 MPa / 28% LR
1,1,1-Trichloroethane 25° C 52 MPa / 100% R
Alkalis
50% NaOH (Caustic) 25° C 51 MPa / 99% R
Bleach
10% Sodium hypochlorite 25° C 40 MPa / 77% R

KEY - * Based on Reference


R - Resistant (subject to a reasonable standard of housekeeping).
LR - Limited Resistance i.e. occasional spillage provided it is quickly washed down or rapidly evaporated.
NR - Not Resistant.
The classification ‘Resistant’ has been given where samples have retained more than 70% of their compressive strength and have not
lost or gained more than 3% of their weight when totally immersed in the environments. Experience has shown that this interpretation
correlates well with practical applications. As a result the above table has been compiled as a guide to the suitability of correctly applied
screeding material provided that a reasonable standard of housekeeping is maintained during service. End users should satisfy
themselves that the screeding material is suitable for their particular environmental conditions and take into account the mechanical duty
which may accompany any chemical spillage.
It should also be noted that some environments (especially inorganic chemicals) will affect the colour of the screeding material on the
surface.

Mixing ratios and mixing weights with appropriate yields

System Base *1 Activator *1 Aggregate *2 Yield Spread rate


None – but may be used 13,33 m² per litre at 75
Laminating 3,479 kg or 2,074 kg or with chemical resistant 5 litres micron wft (no loss taken
3 litres 2 litres non-woven mat into account)
None – but may be used 13,33 m² per litre at 75
Sealing 3,479 kg or 2,074 kg or with chemical resistant 5 litres micron wft (no loss taken
3 litres 2 litres non-woven mat into account)

Screed 1,057 kg 0,630 kg 8,0 kg 5 litres 1 litre per m² yields 1 mm


film thickness

Grout 1,057 kg 0,630 kg 8,0 kg 5 litres 1 litre per m² yields 1 mm


film thickness

*1 - may be mixed 3:2 by volume, but proportioning by weight is best


*2 - use 20051008 aggregate
Revision 9203