Anda di halaman 1dari 26

Smartec Technologies.

HAPPY Elevator Control System


Can be up to 15 Floors down collective in a single board

Product specification
WE906-06

FreeHold NJ USA e-mail: us.support@smartectechnologies.com

55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon Tel:+961 1 278956 www.smartectechnologies.com

5/15/2012
Smartec Technologies.

HAPPY Elevator Control System


Can be up to 15 Floors down collective in a single board + Relay

Product specification
WE906-06

FreeHold NJ USA e-mail: us.support@smartectechnologies.com

55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon Tel:+961 1 278956 www.smartectechnologies.com

5/15/2012
Smartec Technologies.

Ext -Happy up to 8 Stops Down Collective

FreeHold NJ USA e-mail: us.support@smartectechnologies.com

55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon Tel:+961 1 278956 www.smartectechnologies.com
The information contained in this document is the proprietary information of Smartec Technologies.
The contents are confidential and any disclosure to persons other than the officers, employees, agents or
subcontractors of the owner or licensee of this document, without the prior written consent of Smartec
Technologies, is strictly prohibited.

Further, no portion of this publication may be reproduced, stored in a retrieval system, or transmitted in
any form or by any means, electronic or mechanical, including photocopying and recording, without the
prior written consent of Smartec Technologies, the copyright holder.

Smartec Technologies publishes this manual without making any warranty as to the content contained
herein. Further Smartec Technologies reserves the right to make modifications, additions and deletions
to this manual due to typographical errors, inaccurate information, or improvements to programs and/or
equipment at any time and without notice. Such change will, nevertheless be incorporated into new
editions of this manual.

All rights reserved.

© Smartec Technologies 2012-05-15

Publication number: MNH 224 1876 R1A

MNH 224 1876 R1A

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 1
HAPPY BOARD Elevator Control System
Can be up to 15 floors down collective in a single board.

Smartec Technologies specializes in the design and production of high technology electronic
products. Today's electronic product development requires the skillful blend of expert hardware and
software engineering together with a spirit of creativity and innovation, tempered by the practical
concerns of manufacturability, cost consciousness, testability and on-time delivery. With hundreds of
successful project completions, Smartec is uniquely suited to engineer your concept into reality. Smartec
will work with your idea, perform detailed design, construct prototype units, refine the prototype design
and manufacture your electronic product. Fast accurately, on time and on budget.

General Description:

HAPPY Board Elevator Control System is a state-of-the-art high-speed Microcomputer based


elevator control system that continuously collects and evaluates traffic demand patterns for each
individual elevator car and the entire elevator system. Based on real time events when compared to
predicted traffic conditions and anticipated system demands, the HAPPY Board Elevator Control System
automatically modifies its dispatching parameters to optimize system operation.

Individual elements of the HAPPY Board Elevator Control System (Group Supervisory Panel, Car
Control System, Motion Control System and Drive Control System) were created to interface in a
cohesive manner to provide an elevator system with unmatched ride quality characteristics while
exceeding the most stringent performance requirements.
HAPPY Board Group Supervisory Panel Operating under standard serial communications protocol,
the HAPPY Board Group Supervisory Panel constantly monitors and analyzes changing traffic demands
to predict the future movement of the entire elevator system and to create a real time traffic pattern
scenario. Based in part on the following factors: (a) elevator status, (b) elevator direction of travel and
hoist way position, (c) hall call assignments, (d) car call patterns, (e) door position, (f) stopping
parameters, and (g) systems conditions, the HAPPY Board Group Supervisory Panel automatically
recognizes any fluctuations in traffic conditions and immediately adjusts the system operation.

Combining real time conditions, historical traffic patterns and predicted system demand, the HAPPY
Board Group Supervisory Control System continually creates an arrival time prediction diagram for each
elevator car and constantly calculates the shortest waiting time when making a hall call assignment.

HAPPY Board Car Control System Utilizing sophisticated Smartec’s Microcomputer technology and
advanced distributed controller design concepts, the HAPPY Board Car Control System uses a
distributed control network to provide an extremely powerful and incredibly flexible elevator control
system. Operating under the Plug And Play® communications protocol (interconnected communication
via high-speed serial data links), the HAPPY Board Car Control System continuously distributes control
to specific sections of the elevator car (elevator car top, elevator car operating panel, elevator hall
fixtures, etc.) to provide superior system performance.

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 2
Main features
Platform Risk processor
Type Single – Dual Speed - VVVF - Hydraulic
Mode Simplex,Simlpo & Group
Fault Capture Display more than 200 fault messages
Status information Status of the elevator, door, mode and Limit switch Up&Down are displayed
Fault count Calculate fault of type 2
Shaft information End of the Shaft in the Up, Down Direction
Slow down in the final stop in Up, Down Direction
Level Zone
Elevator Position is saved at each stopped
Indicator signal Gray, Binary
Number of Stops 11,15 and up to 31 Stops
Door Type Swinging, Automatic and Semi Automatic
Door Controls 3 input are:
Door parking Status Parking Opened or Closed door
Floor Stop Time Time of Stopping at each station
Home floor Home Floor Number
Car Light Light timer
Home Floor timer Automatic Return to Home floor after preset time
Gong Output
Inspection Mode Elevator goes to inspection/service mode
Drop Out To Cancel all the out side calls
No Load At preset # will Cancel all the inside calls if the door wasn’t opened
Full Load The elevator will not served the out side calls
Emergency Stop It will stop immediately and cancel all inside calls
Fireman Operation It will Cancel all calls and go to Fireman floor
Communication Dual row connector port used To Monitor and controlling elevator Installation

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 3
Main Screen
This is the main screen program screen, you can go either to browse all errors occurs or to edit all
parameters, also you can monitor the elevator status, direction and floor number.

INC
Insp ņ
DEC
LUP: 0 LDN: 0 DO
SELECT

1- LUP: Limit switch up. LUP=0 ĺ switch is off , LUP=1ĺ switch is on.
2- LDN: Limit switch down. LDN=0 ĺ switch is off , LDN=1ĺ switch is on.
3- (DO/Dc): Door open or Door close.
4- INC: Go up.
5- DEC: Go Down.
6- SELECT: Change value.

Selection one of the available screen

Parameter .
Fault.
Function.
You must press increment or decrement then press select to be selected.

Parameter Screen

INC
Parameter
DEC
Select Prev Next
SELECT

Press SELECT to enter passward

The passward is: ********

INC

DEC
Psd 00000000
SELECT

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 4
INC Parameter Number
FLr Stp Tmr 01
DEC
Value = 0 Sec Parameter Value
SELECT
Parameter Name

1- Select: Value blinks


2- Inc: Increase value.
3- Dec: Decrease value
4-Select: Fix value.

Error Screen:
In this screen you can see all error occurred in the elevator from the last reset of error.

INC
00- Safty Jammed.
DEC
01- Door Open In Travel.
SELECT
Function Screen

INC
Functions
DEC
Select Prev Next
SELECT

Press SELECT to activate CALL

1- SDN: Service down or inspection down.


2- SUP: Service up or inspection up.
3- FL: floor number.
4- CALL: Call floor number.

press INC to increase CALL.

INC
FL CALL
DEC
SDN SUP 00 00
SELECT

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 5
Press DEC or select to EXIT.

INC

DEC
SDN SUP EXIT
SELECT

1- Press DEC to activate SUP.


2- press SELECT to activate SDN.
3- press INC to EXIT.

Then press INC until CALL reaches (E) value ,wait 3sec then go to main screen.

INC
Insp ņ
DEC
LUP: 0 LDN: 0 DO
SELECT

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 6
Table 1: PARAMETERS
Parameter Parameter Descriptiom on
LCD Parameter Full Description Default Value ValueRange
number
1 FLOOR STOP TIMER Time between travels in sec 10 1 Æ 15 sec
Swinging
2 DOOR TYPE Door Type Swinging
Semi Aut ⁄ Aut
LEVEL ZONE None / Installed
3 Level of each floor None
NC/Installed NO
4 MAX. COUNT OF ERR Maximum count before blocking 0 1 Æ 254
5 BASEMENTS Basement counts. 0 0Æ9
6 HOME FLOOR Floor of which is station on 0 0Æ31
7 HOME FLOOR TIMER Time out to go home floor 0 1 Æ 1800 sec
8 NO LOAD Multi calls any body open door 3 0Æ9
9 COLLECTIVE Collective Down Down / Full
HOMING ON POWER If enable, make a home trip at
10 Disable Enable / disable
startup
11 TRUNCATE Empty the fault log N/A
AUTOMATIC DOOR
12 OPN/ CLS DOOR TIME The Time of the open or close 6 5Æ31 sec
PARKING STAT DOOR The Status of the door when reach
13 Close Close / Open
the station
15 LIGHT TIME Cabin light timer 5sec 1 Æ60sec
SECONDARY
16 KEEP CLOSE Keep door active during travel Disable Enable / disable
17 RETRY GAMMA: Only for swinging door 3 3 Æ 10 time
RETRY GAMMA
18 Gamma retry timer 3 3 Æ 30 sec
TIMER
PULSE TIME OUT After the magnet time out has
20 14 1 Æ 99 sec
passed then the elevator will block
YAL TIMER Retry Yale time to next retry
21 5 1 Æ 60 sec
delay in sec.
PRE-RELEASE Reactive Gamma when level zone
22 Disable Enable / disable
is reached
23 FIREMAN FLOOR N/A
24 FLOOR EXPANSION See table 2 0 0-8
25 HARDWARE EXT. See table 3 0 0,1,2,3
27 INDICATOR TYPE Gray Gray, Binary,
29 LMT SW DURING INS enable Enable / disable
30 COUNT OF DAYS 0 day 0Æ9999 days
32 FLR STOP TIME OUT N/A
33 COMPANY NAME Name of company Smarte --
c
34 SERIAL NUMBER Board serial number --
35 HARDWARE VERSION Board hardware version --
36 FIRMWARE VERSION --
HYDRAULIC AND VVVF ELEVATOR
37 VVVF / HYD STP DELY 0 0 Æ30 sec
38 VVVF START DELAY 0 0 Æ30 sec
41 HYDRA START TIME 0 0 Æ 99 msec
42 DOOR BUSY On case of duplex only 0 0 Æ 31sec
43 PASSENGER CAPACITY 0 0 Æ 15
44 DRIVE / VVVF TYPE
45 USER PASSWORD ********

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 7
Fault Description:

Error Displayed Description Controller Action Solution


on LCD
Elevator is Jammed Motor powered but Block Check the Brake or Pines,
car didn’t move Turn electricity off then on.
SDFS Pulse Missed Pulses Reset and make home trip Check the pines or magnet.

Limit switch Up LMTSW_UP fault Block Check Switch up,


Turn electricity off then on.
Limit switch Down LMTSW _DN fault Block Check Switch down,
Turn electricity off then on.
Limit switch up & LMTSW _UP fault & Block Check Switch up & Down,
Down LMTSW _DN fault Turn electricity off then on.
Gamma Gamma fail in Cancel calls Check Gamma
contactor up
Yale Yale is opened Cancel calls Check Yale

Door Open in travel Door Lock circuit Wait for lock circuit, Check Yale
open during travel Cancel calls if fault
persists more than 5 sec
Aux NC Safety and Ready Waits for Ready circuit to Check Aux Nc or Yale
circuits are open close
Safety Jammed Contactor up or down Waits for Ready circuit to Check Contactor UP or Down
jammed close
System Timeout Count days of Block Contact the System
operation expired Administrator.
Stop Key Stop key Error Complete cycle Check Stop Key.

PTC overheating Motor Temperature Elevator will not take calls Wait for motor to cool
exceeds limits. after the first stops. Or disable PTC.

HAPPY Controller Board Capable of storing more than 200 faults


can be displayed on the LCD screen.

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 8
Selecting Hydraulic

To turn on the hydraulic function in the controller the “Hydra Start time” must be >0
To set the hydraulic time to the value desire in 100th ms increments
Ex: Value = 15 (Means 1.5s or 1500 ms).

Displaying Error in Binary or Gray:

Error Display Output


Limit Switch UP 31 = LU
Limit Switch Down 30 = LD
Limit Switch UP & Down 29 = UD
System Timeout 28 = ST
Elevator Jammed 27 = EJ
Max Error 26

(1)
Table 2: HAPPY Floor Expansion (parameter 24) :

Value description

0 Up to 15 Stops Down Collective without flashing outside calls.

8 Up to 15 Stops Down Collective with flashing outside calls.

Hardware Extension (Parameter 25) (1):


Hardware extension used to add more station as needed are:

Table 3:

HAPPY
Hardware Ext # Down Collective Full Collective
0 Up to 15 Stops Up to 11 Stops
1 23 stops 16 stops
2 31 stops 22 stops
3 39 stops 27 stops

Note: if Hardware Extension (25) > 0, Floor Expansion (24) must be 0.

(1):
See table (1)

FreeHold NJ USA e-mail: us.support@smartectechnologies.com Happy board controller


55Hamdan bldg., Suite UG., Milano st. Hadath – Lebanon www.smartectechnologies.com 9
15 STOPS CONNECTION DIAGRAM ( Floor Expansion Parameter(24)=0 ) NO FLASHING OUTSIDE CALLS
( Floor Expansion Parameter(24)= 8) FLASHING OUTSIDE CALLS
SP1 SP2 ARO AROĻ
SLO DNW UP HI NC LITE OPE CLSECOM2 E D C B A (--) (+) 8D 7D 6D 5D 4D 3D 2D 1D 0D 8F 7F 6F 5F 4F 3F 2F 1F 0F
I O Ĺ 18F+
OUT PUTS 22 volt OUTSIDE CALLS INSIDE CALLS

W: 5.329 IN ĺ 13.53cm L: 9.491 IN ĺ 24.10cm

HAPPY BOARD CONTROLLER


INPUTS 17 volt
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 AC/DC
DRO CLS FORC
DOR DOR
UP DN LSUP LSDN SEN SUP SDN P STP XOF XON E E FULL VVVF LZ Fireman 9F 10F 11F 12F PTC 13F 14F B A 17 VAC 9D 10D 11D 12D 13D 14D
E.O E.C
OUT CIR CLSE

Outputs Inputs
HAPPY Main Features:
1- Slow //Delta 1 1- PULSE_UP: Magnetic switch up direction.
2- Down 2 2- PULSE_DN: Magnetic switch down direction Up to 15 stops down collective.
3- Up // Star 1,2 3- LMTSW_UP: Limit switch Up direction Group up to 4 Elevators.
4- High 2 4- LMTSW_DN: Limit switch Down direction Outputs drive can be 60v transistors or Relays "60V, 110V, 220V".
5- No connection 5- SERV_EN: Service enable Voice prompt "option".
6- Car light 6- SERV_UP: Service Up enable Floor Expansion Parameter(24)
7- Open 7- SERV_DN: Service Down enable Value Description
8- Close/CAM 8- DROP_OUT: Cancel out side calls 0 Up to 15 stops down collective without flashing outside calls.
9- Com2 9- STOP: Emergency Stop. 8 Up to 15 stops down collective With flashing outside calls.
10- Spare1 10- Aux_Off: Contactor Up Direction Aux
11- Spare2 11- Aux_On: Contactor Down Direction Aux
12- ARO Ĺ 12- Close Circuit: Active High when the doors circuit are completely engaged.
13- ARO Ļ 13- Force_cls: Force automatic door to close and cancel the timeout
14- E 14- Auto_D_C: Automatic Door close switch
15- D 15- Auto_D_O: Automatic Door open switch
16- C 16- Over_Capacity: Will not take any outside calls
17- B 17- VVVF: VVVF Control Signal.
18- A 18- Level Zone: Level zone switch.
19- Fireman: Fireman Switch
24- PTC Active Low

1 Activates Hydraulic: You must set ( Hydraulic Start Time ) > 0 Time in 100's ms ex. 11 = 1.1sec
2 VVVF: RAM UP, RAM DOWN, High = Constant Slow Speed

smartec Technologies Copyright ® 2012 HAPPY BOARD CONTROLLER page: 10


8 7 6 5 4 3 2 1

N L3 L2 L1

B1
BRIDGE
POWER TRANSFORMER

F L3
F L2
F L1
380VAC11 1 60VAC ~ + Q1 (+60VDC)
F1/4A F1/4A3
Q1 (+60VDC)
2 0VAC ~ - 0VDC
220VAC 3
10VAC-->24VAC H2 Q2(+22VDC)

2
2
2
4 0VAC D1
SW1 110VAC 5 Q22
10VAC -->24VAC F2/4A ~ +

1
1
1
C1 C2
6 0VAC 3300uF Cup
3300uF Cdn
7 ~ - 0VDC
(220VAC)
8 0VAC B2 BRIDGE
9

2
2
2
(110VAC)
0VAC 12 10 0VAC
PMD

1
1
1
5
6
T1

2
3
SW2 1 L1
S1= SAFETY1:-Q1=6OVDC 2 L2
48VAC 3 L3 P1 7

4 N P2 8 Chi Clo
60VAC
65VAC
L1-PMD 110VAC
220VAC
L1 F3/2A

L2 F4/2A

L3 F5/2A
BRAKE
N

A Cdn Cup A
0VDC
SW1: Main circuit breaker
SW2: Thermo-magnetic circuit breaker in control panel
Cdn: Down direction contactor
Chi Clo L1-PMD
Chi: High speed contactor
Clo: Slow speed contactor
Cup: Up direction contactor
2

MPR: Motor protection relay


0VDC 0VAC
PMD: Phase balance and phase sequence monitoring device
1

MPR
Q22 (+22VDC --> +48VDC) (*)
H2 (17VAC --> 24VAC)

PTC: connected to the PTC input in the EMW2.15 board


U1 V1 W1
U2 V2 W2
FL1, FL2, FL3, F1, F2, F3, F4 & F5: Fuses 1 1 4 4 (+) (-) 17V~
2 M 5
2 3~ 5 Typical
3 3 6 6
B1, B2: BRIDGE HAPPY BOARD
7
7

MOTOR 3P CONTROLLER

PTC
(*): Optional feature
HAPPY BOARD
CONTROLLER

SMARTEC page description: project: date:


Technologies Inc.
June 14, 2012
55Hamdan bldg., Suite UG., Milano Rd.
Beirut - Lebanon POWER DIAGRAM HAPPY BOARD CONTROLLER page:
Telefax: + 961 1 278 956
1 of 13
www.smartectechnologies.com

8 7 6 5 4 3 2 1
A B C D E F G H

VVVF 3-SPEED MOTOR HAPPY 15 STOPS, MANUAL / AUTOMATIC DOOR

For Manual Door


GO TOP GO ROOM GO PIT OT_DN OT_UP M1= 0VDC if S1= Q1
LD SAFETY1= S1 = 0VAC if S1= VAC
ROPE STOP STP INSP STOP IN PIT
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

DO SAFETY1:-Q1=6OVDC
48VAC

A1
* Rdw Q12
~ 60VAC

A2
65VAC
110VAC 0F__14F:INSIDE CALLS
For Auto Door For Manual Door 220VAC
0VDC
0D__14D:OUTSIDE CALL
S1 S1 S1

2
2
2
2
2
0VDC (+22VDC)

1
1
1
1
1

KCup
KCdn
INDICATOR (+22VDC) 14D 13D 12D 11D 10D 9D 8D 7D 6D 5D 4D 3D 2D 1D 0D 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F
Rlt Rop Rcl Rcm M1 0VDC Q2
GRAY OR BINARY CODE

A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
*Clo * Cdn * Cup * Chi M1 * CP1 CP2 * * * *
~ ~ ~ ~ ~ ~ ~ ~ ~ ~

A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
SLOW DOWN UP HIGH COM1 SPARE1 SPARE2 LIGHT OPEN CLOSE CLOSE COM2 E D C BA (-) (+)

ARO UP
ARO DN
For Manual Door For Auto Door
HAPPY BOARD CONTROLLER

A DROP DUPLEX A
STP XOFF XON 17V~

LZ

CLSE CIRC
CLSE CIRC
FIRE

DOR EO
DOR EC
UP DN LSUP LSDN SUP SDN SEN OUT PTC B1 A1

VVVF

FORCE CLSE
FULL

1
BOP

N.C.

1
1
1
1
1
1
CE

2
1
1
1

1
1
1
PC

K2Cdn

2
2
2
2
2
2
N.C.
LZ

1
2
2
2
0VAC
(17VAC)

2
2
2
2
1
FIRE

SEN
Rdw

K1Cup

1
1

K1Cdn

1
FCL EO EC

1
1
2
to other board

FULL
CS DJ PTC

2
2

2
1

K2Cup
1
OL OL

2
Q22

2
Q22 (+22VDC)
(+22VDC)
MONOSTABLE MAGNETIC SWITCHES
Q2 (+22VDC)
(*): do not install diodes with contactors if V1 was 110 VAC OR 220 VAC (*): Q2 & Q22 see page 1
L : Lock door contact CP1: Medium speed relay K1Cdn: Auxiliary switch for down direction relay
Rdw : Door contact relay CP2: Inspection break relay K1Cup: Auxiliary switch for up direction relay
DO : Door contact mechanical switch Rlt: Light relay RDW: Door Contact Relay
STP INSP: Stop inspection top of cabine rope stop Rop: Open door buttom OL: Overload switch
GO TOP : Overspeed governor top of cabine Rcl: Close door buttom BOP: Push button to reopen automatic door
GO ROOM : Overspeed governor machine room Rcm: CAM relay for swinging door (GAMMA) PC: Photocell switch
GO PIT: Overspeed governor pit UP: Pulse Up DJ: Door jam switch
OT_DN: Over travel down mechanical limit switch stop in pit DN: Pulse Down OL: Overload Switch
OT_UP : Over travel up mechanical limit switch LSUP: Limit Switch Up FCL: Push button close door immediately
KCup : Auxiliary switch for up direction relay,should be NORM.CLOS. LSDN: Limit Switch Down EO: Limit switch end of opening
KCdn : Auxiliary switch for down direction relay,should be NORM.CLOS. SUP: Additional Limit Switch Up EC: Limit Switch End Of Closing
Clo : Slow speed relay SDN: Additional Limit Switch Down
Cdn: Down direction relay FULL: Full load switch
SEN: Service enable switch LZ: Level Zone
Cup: Up direction relay CE: Car Emergency Push Button
Chi: High speed relay FIRE: Fireman switch
CS: Car Step Switch
COM1: Commun for relay (Down,Up,Slow & high) is Connected to 0Volt (M1) K2Cdn: Auxiliary switch for down direction relay
PTC: PTC from the motor
DUPLEX:Used in duplex mode to be connected
COM2: Commun for relay (Light, Open & Close) is Connected to 0Volt (M1) K2Cup: Auxiliary switch for up direction relay to other board

date:
SMARTEC Technologies Inc. page description: project:
55Hamdan bldg., Suite UG., Milano Rd. June 14, 2012
Beirut - Lebanon VVVF 3-SPEED MOTOR - HAPPY 15 STOPS, MANUAL / AUTOMATIC DOOR
Telefax: + 961 1 278 956 HAPPY BOARD CONTROLLER page:
www.smartectechnologies.com 2 of 13
A B C D E F G H
A B C D E F G H

VVVF 2-SPEED DRIVE HAPPY 15 STOPS, MANUAL/AUTO DOOR

GO TOP GO ROOM GO PIT OT_DN OT_UP


SAFETY1= S1
ROPE STOP STP INSP STOP IN PIT
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 SAFETY1:-Q1=6OVDC M1= 0VDC if S1= Q1
DO 48VAC = 0VAC if S1= VAC
Q12 60VAC
65VAC
110VAC
220VAC
Q2=22VDC

For Auto Door For Manual Door 0F__14F:INSIDE CALLS


FAULT RELAY
S1 S1 S1 0D__14D:OUTSIDE CALL
VVVF DRIVE (+22VDC)
Slow Ramp Ramp 1 2
0VDC Q2
inspection
ramp DN UP HI COM
/ Break

S1 INDICATOR (+22VDC) 14D 13D 12D 11D 10D 9D 8D 7D 6D 5D 4D 3D 2D 1D 0D 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F
Rop Rcl M1 0VDC Q2
GRAY OR BINARY CODE

A1
A1
A1
A1
A1
*INS Rlt * Rcm
* * *
~ ~ ~ ~ ~

A2
A2
A2
A2
A2
SLOW DOWN UP HIGH SPARE 2 COM1 VVVF LIGHT OPEN CLOSE CLOSE COM2 E D C BA (-) (+)

ARO UP
ARO DN
HAPPY BOARD CONTROLLER
For Manual Door For Auto Door

A DROP A
DUPLEX
STP XOFF XON 17V~

LZ
CLSE CIRC
CLSE CIRC
FIRE

DOR EO
DOR EC
UP DN LSUP LSDN SEN SUPSDN OUT PTC B1 A1

FORCE CLSE
FULL

1
BOP

N.C.

1
1
1
1
CE

1
2
2
2
1
1

1
1
1
PC

K2Cdn

2
2
2
2
LZ
2
1
1
1
2
2
0VAC
(17VAC)

2
2
2
2
1
FIRE

SEN
SUP
SDN
Rdw

1
1

K1Cdn
K1Cup

1
FCL EO EC

1
1
2
to other board

FULL
CS DJ PTC

2
2

2
1

K2Cup
1
OL OL

2
Q22

2
Q22
(+22VDC)
(+22VDC)
MONOSTABLE MAGNETIC SWITCHES
Q2 (+22VDC)
(*): do not install diodes with contactors if S1 was 110 VAC OR 220 VAC
DO: Door Contact Mechanical Switch LSDN: Limit Switch Down BOP: Push Button To Reopen Automatic Door
GO TOP: Overspeed Governor Top Of Cabine SEN: Service Enable Switch DJ: Door Jamp Switch
GO ROOM: Overspeed governor machine room SUP: Service Up switch FCL: Push Button Close Door Immediately
GO PIT: Overspeed Governor Pit SDN: Service Down Switch EO: Limit Switch End Of Opening
OT-DN: Over Travel Down Mechanical Limit switch CE: Car Emergency Push button EC: Limit Switch End Of Closing
OT UP: Overtravel Up Mechanical Limit Switch CS: Car Step Switch FULL: Full Load Switch
Rlt: Light Relay K2Cdn: Auxiliary Switch For Down Direction Contactor LZ: Level Zone
Rop: Open Door Buttom K2Cup: Auxiliary Switch For Up Direction Contactor
Rc1: Close Door Buttom FIRE: Fire man Switch
Rcm: cam Relay For Swinging Door(GAMMA) K1Cdn: Auxiliary Switch For Down Direction Contactor PTC: PTC from the motor
K1Cup: Auxiliary Switch For Up Direction Contactor DUPLEX: used in duplex mode to be connected
UP: Pulse Up to the other board
DN: Pulse Down Rdw: Door Contact Relay
COM1: Commun for Relay (Down,Up,Slow& Inspection)
LSUP: Limit Switch Up OL: Overload Switch is Connected to PIN COM to VVVF Drive

SMARTEC Technologies Inc. page description: project: date:


55Hamdan bldg., Suite UG., Milano Rd. June 14, 2012
Beirut - Lebanon
VVVF 2-SPEED DRIVE _HAPPY 15 STOPS, MANUAL/ AUTO DOOR HAPPY BOARD CONTROLLER
Telefax: + 961 1 278 956 page:
www.smartectechnologies.com 3 of 13
A B C D E F G H
A B C D E F G H

15 STOPS DOWN COLLECTIVE

Q2 (+22VDC) LANDCALLS DOWN Q2 (+22VDC) CARCALLS

14 14
13
13
12 12

11 11

10 10

9 9

8 8

7 7

6 6

5 5

4 4

A 3 3 A

2 2

1 1

0 0

GND GND

9D
8D
7D
6D
5D
4D
3D
2D
1D
0D
9F
8F
7F
6F
5F
4F
3F
2F
1F
0F

14D
13D
12D
11D
10D
14F
13F
12F
11F
10F

HAPPY BOARD CONTROLLER

page description: project: date:


SMARTEC Technologies Inc.
June 14, 2012
55Hamdan bldg., Suite UG., Milano Rd.
Beirut - Lebanon 15 STOPS DOWN COLLECTIVE HAPPY BOARD CONTROLLER
Telefax: + 961 1 278 956 page:
www.smartectechnologies.com 4 OF 13

A B C D E F G H
5 4 3 2 1

15 STOPS FULL COLLECTIVE


SERIAL CONNECTION
D D

(+22VDC)
DP CABIN BOARD

14
13
DUPLEX 12 WIRE
DP 11 Flat Cable Needed for Serial Installation
COUNT
LIFT A LIFT B 10
P P 9 1 + 24 VDC
8
1 - 24 VDC
GND GND 7
6 1 A RS485 Serial Communication
5 1 B RS485 Serial Communication
C Push Button Diagram 4 C
2 For Auto/Manual Safety Line 60VDC
3 + 3
2 TOTAL WIRES 6
1
+ 1
0
+
2 GND

A 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F


HAPPY BOARD CONTROLLER
B CABIN BOARD

WIRE
Optional wires
(+22VDC) (+22VDC) COUNT
DP PANEL BOARD DP PANEL BOARD
1 Neuter 220VAC, not required if Light 24VDC used
14 14
1 Phase 220VAC, not required if Light 24VDC used
B
13 13 B

12 12 2 For Parachute
11 11 2 Siren For Emergency
10 10
TOTAL WIRES 6
9 9
8 8
7 7
6 6
5 5
4 4
3 3

SERIAL CONNECTION
2 2
1 1
0 0
GND GND

A B 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2D 1D 0D 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F
HAPPY BOARD CONTROLLER
A A

PANEL BOARD

page description: project: date:


SMARTEC Technologies Inc. June 14, 2012
55Hamdan bldg., Suite UG., Milano Rd.
15 STOPS FULL COLLECTIVE
Beirut - Lebanon HAPPY BOARD CONTROLLER page:
Telefax: + 961 1 278 956 SERIAL CONNECTION 5 OF 13
www.smartectechnologies.com
5 4 3 2 1
5 4 3 2 1

(+22VDC)
H6
INSIDE CALLS

30 STOPS, VVVF 2-SPEED AUTOMATIC /SWINGING DOOR 29

28

27
D D

26
CABIN BOARD DIAGRAM 25

SERIAL CONNECTION 24

23

22

21

20

19

18

17

16

15

14

13

12

11
C C

10

7
6

For Auto Door For Manual Door 4

3
S1 S1 S1 2
0VDC (+22VDC) 1

INDICATOR (+22VDC) SUP


Rlt Rop Rcl Rcm M1 0VDC Q2
GRAY OR BINARY CODE

A1
A1
A1
A1
* * * *
~ ~ ~ ~
SDN

A2
A2
A2
A2
B
LIGHT OPEN CLOSE CLOSE COM2 E D C BA (-) (+) 14D 13D 12D 11D 10D 9D 8D 7D 6D 5D 4D 3D 2D 1D 0D 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F
B

ARO UP
ARO DN
A
HAPPY BOARD CONTROLLER TO PANEL BOARD
For Manual Door For Auto Door B

DROP
STP 17V~

CLSE CIRC
CLSE CIRC
FIRE

DOR EO
DOR EC

UP DN LSUP LSDN SEN OUT PTC B1 A1


VVVF

FORCE CLSE
FULL

LZ
BOP

N.C.

1
1
1
1
CE

2
1
1

1
1
PC

2
2
2
2
N.C.

DUPLEX

1
2
2
0VAC

LZ
(17VAC)

2
FIRE

2
2
1

SEN
Rdw

2
1

1
FCL EO EC
1
1
2
FULL

CS DJ PTC
2

2
1
1

A OL A
OL
2
Q22
2

Q22
(+22VDC)
(+22VDC)

MONOSTABLE MAGNETIC SWITCHES Q2 (+22VDC)

SMARTEC Technologies Inc. page description: project: date:


55Hamdan bldg., Suite UG., Milano Rd. June 14, 2012
Beirut - Lebanon 30 STOPS, VVVF 2-SPEED AUTOMATIC /SWINGING DOOR HAPPY BOARD CONTROLLER page:
Telefax: + 961 1 278 956 6 of 13
www.smartectechnologies.com

5 4 3 2 1
5 4 3 2 1

(+22VDC)
H6
OUTSIDE CALLS

29

28

30 STOPS, VVVF 3 -SPEED AUTOMATIC / SWINGING DOOR 27

26
D D

25
PANEL BOARD DIAGRAM 24

SERIAL CONNECTION 23

22

21

20

19

18

17

16

15

14

13

12

11

10
C C
GO TOP2GO ROOM2 GO PIT2 OT_DN2 OT_UP2
SAFETY1= S1
ROPE STOP2 STP INSP2 STOP IN PIT2 9
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

8
DO2
Q12 7
6

5
Q2=22VDC

For Auto Door For Manual Door 4

FAULT RELAY 3

VVVF DRIVE
S1 S1 S1 2
(+22VDC)
Slow Ramp Ramp 1 2
0VDC Q2 1
inspection
ramp DN UP HI COM
/ Break
0

S1 INDICATOR (+22VDC)
Rop Rcl M1 0VDC Q2
GRAY OR BINARY CODE

A1
A1
A1
A1
A1
*INS Rlt * Rcm
* * *
~ ~ ~ ~ ~

A2
A2
A2
A2
A2
SLOW DOWN UP HIGH SPARE 2 COM1 VVVF LIGHT OPEN CLOSE CLOSE COM2 E D C BA (-) (+) 14D 13D 12D 11D 10D 9D 8D 7D 6D 5D 4D 3D 2D 1D 0D 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F

B B

ARO UP
ARO DN
A
TO CABIN BOARD
HAPPY BOARD CONTROLLER B

DROP
OUT STP XOFF XON PTC B1 A1 17V~

N.C.
CE

2
1
1

K2Cdn
DUPLEX
0VAC
(17VAC)

2
2

1
K1Cdn
K1Cup

1
CS PTC

2
K2Cup
A A

Q22
(+22VDC)

SMARTEC Technologies Inc. page description: project: date:


June 14, 2012
55Hamdan bldg., Suite UG., Milano Rd.
Beirut - Lebanon HAPPY BOARD CONTROLLER page:
30 STOPS, VVVF 3 -SPEED AUTOMATIC / SWINGING DOOR 7 of 13
Telefax: + 961 1 278 956
www.smartectechnologies.com

5 4 3 2 1
A B C D E F G H

(+22VDC) 15 STOPS DOWN COLLECTIVE (+22VDC)


Q2 Q2
DUPLEX LANDCALLS DOWN CARCALLS
P P3 2 1
14 14
LIFT A LIFT B
P P 13 13
12 12
GND GND 11 11
10 10
9 9

Push Button Diagram


8 8

3 +
7 7
6 6
5 5
+ 1 4 4
+ 3 3
2
2 2
1 1
0 0
GND
GND

9D
8D
7D
6D
5D
4D
3D
2D
1D
0D
9F
8F
7F
6F
5F
4F
3F
2F
1F
0F

HAPPY BOARD CONTROLLER

14D
13D
12D
11D
10D
14F
13F
12F
11F
10F

A A
(+22VDC)
(+22VDC) (+22VDC) 11 STOPS FULL COLLECTIVE Q2
Q2 Q2 P3 CAR calls 2 1
10
P3 LANDCALLS UP 2 1 P3 LANDCALLS Down 2 1
9 10 9
8 9 8
7 8 7
6 7 6
5 6 5
4 5 4
3 4 3
2 3 2
1 2 1
0 1 0
GND GND GND

HAPPY BOARD
1D
0D
8F
7F
6F
5F
4F
3F
2F
1F
0F

9D
1D
9F
8D
7D
5D
4D
3D
2D

6D

CONTROLLER

14D
13D
12D
11D
10D
14F
13F
12F
11F
10F

SMARTEC Technologies Inc. page description: project: date:


June 14, 2012
55Hamdan bldg., Suite UG., Milano Rd.
Beirut - Lebanon HAPPY BOARD CONTROLLER
Telefax: + 961 1 278 956 DUPLEX DIAGRAM page:
www.smartectechnologies.com 8 OF 13

A B C D E F G H
A B C D E F G H

VVVF 3-SPEED CONNECTION

1
(FORWARD) (REVERS)
MIDDLE SLOW HIGH VFF Inspection RAMP RAMP

2
SPEED SPEED SPEED 24V /BREAK UP DN

Q2

S1:Q1=6OVDC
48VAC
60VAC
65VAC
110VAC
220VAC
S1 S1
ERROR FLUG

A1
* *

A1
A
~ ~

A2
INS

A2
INS
HI SLOW COM1 UP DNW
SPARE 1 SPARE 2 VVVF

HAPPY BOARD CONTROLLER

(*): do not install diodes with contactors if S1 was 220 VAC or 110 VAC
(*) S1: see page 2,3,7,8

SMARTEC Technologies Inc. page description: project: date:


June 14, 2012
55Hamdan bldg., Suite UG., Milano Rd.
Beirut - Lebanon VVVF 3-SPEED CONNECTION HAPPY BOARD CONTROLLER
page:
Telefax: + 961 1 278 956 9 OF 13
www.smartectechnologies.com

A B C D E F G H
A B C D E F G H

DO GO TOP GO ROOM GO PIT OT_DN OT_UP


SAFETY1= S1
MANUAL/ AUTO DOOR VVVF ROPE STOP STP INSP STOP IN PIT
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

Q2=22VDC SAFETY1:-Q1=6OVDC
Q12 48VAC
60VAC
65VAC
VVVF DRIVE
S1
110VAC
Slow Ramp Ranp S1 220VAC
inspection 1 2
ramp DN UP HI S1

FAULT RELAY
/Break COM AUTOMATIC DOOR

S1

2
2
M1
MANUAL DOOR

1
1

A1
INS
* ~

A1
A1
A1
A1

* Rlt Rcm Rcl Rop


* * *

A2
~ ~ ~ ~

A2
A2
A2
A2

COMMUN
for relay
COMMUN
for relay

SLOW DOWN UP HIGH SPARE 2 COM1 VVVF LIGHT CLOSE OPEN CLOSE COM2

A HAPPY BOARD A
CONTROLLER

(*): do not install diodes with contactors if S1 was 110 VAC OR 220VAC

DO : Door Contact Mechanical Switch RLT: Light Relay


RCM: Cam Relay for Swinging Door
STP INSP: Stop inspection Top of Cabine
Rcl: close door relay
GO TOP: Overspeed Governor Top of Cabine
ROP: open Door Relay
GO ROOM: Overspeed governor machine room
COM1: Commun for relay:(slow,up,down,high& inspection)
GO PIT: Overspeed Governor PIT
is connected to pin com in VVVF drive
OT-DN: Over Travel Down Mechanical Limit Switch
COM2:Commun for relay:(light,close & open)is connected to 0 volt(M1)
OT-UP: Over Travel Up Mechanical Limit Switch

SMARTEC page description: project: date:


Technologies Inc.
55Hamdan bldg., Suite UG., Milano Rd. June 14, 2012
Beirut - Lebanon MANUAL/ AUTO DOOR VVVF HAPPY BOARD CONTROLLER
Telefax: + 961 1 278 956 page:
10 OF 13
www.smartectechnologies.com
A B C D E F G H
A B C D E F G H

AUTOMATIC DOOR
MANUAL / AUTO DOOR , AC2
L1 L2 L3

LD DO GO TOP GO ROOM GO PIT OT_DN OT_UP

ROPE STOP STP INSP STOP IN PIT SAFETY1= S1


1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

SAFETY1:-Q1=6OVDC

A1
* Q12 48VAC Rcl Rop
~ 60VAC
Rdw 65VAC

A2

MANUAL DOOR
110VAC
0VDC 220VAC

S1
AUTOMATIC DOOR F-4 F-5 F-6
S1

2
2
2
KCup KCdn KClo S1

1
1
1
2
2
MANUAL DOOR M1
M1

1
1
* * * *

A1
A1
A1
A1
Cdn Cup Clo Chi
~ ~ ~ ~

A1
A1
A1
A1
* Rlt Rcl Rop Rcm
* * *

A2
A2
A2
A2
~ ~ ~ ~ M 3~

A2
A2
A2
A2
COMMUN
FOR RELAY

DOWN UP SLOW HIGH COM1 LIGHT OPEN CLOSE CLOSE COM2

A A
HAPPY BOARD CONTROLLER

(*): do not install diodes with contactors if S1 was 110 VAC OR 220 VAC

LD : Lock Door Contact KCLO:Auxiliary Switch for Low Speed Contactor should be N.C
DO : Door Contact Mechanical Switch Cdn: Down Direction Contactor
STP INSP:Stop Inspection Top of Cabine CUP: Up Direction Contactor
GO TOP: Overspeed Governor Top of Cabine CLO: Slow Speed Relay
GO ROOM:Overspeed Governor Machine Room Chi: High Speed Relay
GO PIT: Overspeed Governor PIT Rlt: Light Relay
OT-DN: Over Travel Down Mechanical Limit Switch RCL: Close Door Relay
OT-UP: Over Travel Up Mechanical Limit Switch ROP: Open Door Relay
Rdw: Door contact relay Rcm: Cam Relay for Swinging Door
KCUP:Auxiliary Switch for Up Direction Contactor should be N.C COM1:Commun for Relay (Down, Up, Slow & High) is connected to 0volt (M1)
KCDN:Auxiliary Switch for Down Direction Contactor should be N.C COM2:Commun for Relay (Light,Open,& Close) is connected to 0volt (M1)

page description: project: date:


SMARTEC Technologies Inc.
55Hamdan bldg., Suite UG., Milano Rd. June 14, 2012
MANUAL / AUTO DOOR , AC2
Beirut - Lebanon HAPPY BOARD CONTROLLER
Telefax: + 961 1 278 956 page:
11 OF 13
www.smartectechnologies.com

A B C D E F G H
A B C D E F G H

TYPE OF DOOR

+22 V automatic door


+22 V
open button

REOPEN DOOR

manual & cabin door

2
PHOTOCELL SWITCH
2

S16 PHOTOCELL SWITCH

1
manual door
1

+22 V

2
2
push button to close the door

END SWITCH CLOSING

END SWITCH OPENING


Rdw

1
door contact relay DOOR JAM SWITCH

1
rdw

OVERLOAD SWITCH OVERLOAD SWITCH OVERLOAD SWITCH

CLSE CIRC CLSE CIRC DOR EO DOR EC Force cls CLSE CIRC

HAPPY BOARD
HAPPY BOARD HAPPY BOARD
CONTROLLER
CONTROLLER CONTROLLER

SMARTEC
Technologies Inc. page description: project: date:
55Hamdan bldg., Suite UG.,Milano Rd. June 14, 2012

Beirut - Lebanon HAPPY BOARD CONTROLLER page:


TYPE OF DOOR
Telefax: + 961 1 278 956
12 OF 13
www.smartectechnologies.com

A B C D E F G H

Anda mungkin juga menyukai