Anda di halaman 1dari 8

3/20/2019 District heating - Wikipedia

District heating
District heating (also known as heat networks or teleheating) is a system for distributing heat generated in a centralized location through a system of insulated pipes for residential and
commercial heating requirements such as space heating and water heating. The heat is often obtained from a cogeneration plant burning fossil fuels or biomass, but heat-only boiler stations,
geothermal heating, heat pumps and central solar heating are also used, as well as heat waste from nuclear power electricity generation. District heating plants can provide higher efficiencies and
better pollution control than localized boilers. According to some research, district heating with combined heat and power (CHPDH) is the cheapest method of cutting carbon emissions, and has one
of the lowest carbon footprints of all fossil generation plants.[1] Fifth generation district heat networks do not use combustion on-site and have zero emissions of CO2 and NO2 on-site; they employ
heat transfer which uses electricity which may be generated from renewable energy, or from remote fossil fuelled power stations. A combination of CHP and centralized heat pumps are used in the
Stockholm multi energy system. This allows the production of heat through electricity when there is an abundance of intermittent power production and cogeneration of electric power and district
heating when the availability of intermittent power production is low.[2]

Contents
History
Generations of district heating
First Generation
Second Generation
Third Generation
Fourth Generation
Fifth Generation

Heat generation
District heat from combined heat and power or simple combustion The Spittelau incineration plant is one of several
Geothermal-sourced district heat plants that provide district heating in Vienna.
Solar-sourced district heat
Heat pumps for district heat
Excess renewable electrical energy for district heat
Cold district heating

Heat accumulators and storage


Heat distribution
Heat metering
Size of systems
Pros and cons
Ownership, monopoly issues and charging structures
Animated image showing how
National variation
district heating works
Europe
Cogeneration in Europe
Austria
Bulgaria
Czech Republic
Denmark
Finland
Germany
Greece
Hungary
Iceland
Ireland
Italy
Biomass fired district heating power
Netherlands plant in Mödling, Austria
Norway
Poland
Romania
Russia
Serbia
Sweden
United Kingdom
Spain
North America
Canada
United States
Asia
Japan
China

Market penetration Coal heating plant in Wieluń


See also (Poland)
Footnotes
External links

History
District heating traces its roots to the hot water-heated baths and greenhouses of the ancient Roman Empire. Usually, a hot water distribution system in Chaudes-Aigues in France is regarded as the first real
district heating system. It used geothermal energy to provide heat for about 30 houses and started operation in the 14th century.[3]

The U.S. Naval Academy in Annapolis began steam district heating service in 1853.

Although these and numerous other systems have operated over the centuries, the first commercially successful district heating system was launched in Lockport, New York, in 1877 by American hydraulic The cancelled Russian Gorky
Nuclear Heating Plant in
engineer Birdsill Holly, considered the founder of modern district heating.
Fedyakovo, Nizhny Novgorod
Oblast

Generations of district heating


Generally, five different generations of district heating systems can be distinguished.

First Generation
The first generation was a steam-based system fueled by coal and was first introduced in the US in the 1880s and became popular in some European countries, too. It was state of the art until the 1930s and used
concrete ducts, operated with very high temperatures and was therefore not very efficient. There were also problems with reliability and safety due to the hot pressurised steam tubes. Nowadays, this generation
is technologically outdated. However, some of these systems are still in use, for example in New York or Paris. Other systems originally built have subsequently been converted to later generations.[4]

Second Generation The four different generations of


The second generation was developed in the 1930s and was built until the 1970s. It burned coal and oil, the energy was transmitted through pressurised hot water as heat carrier. The systems usually had supply district heating systems and their
energy sources
temperatures above 100 °C, used water pipes in concrete ducts, mostly assembled on site, and heavy equipment. A main reason for these systems were the primary energy savings, which arose from using
combined heat and power plants. While also used in other countries, typical systems of this generation were the soviet-style district heating systems that were built after WW2 in several countries in Eastern
Europe.[4]

Third Generation
In the 1970s the third generation was developed and was subsequently used in most of the following systems all over the world. This generation is also called the “Scandinavian district heating technology”, because a lot of the district heating component
manufacturers are based in Scandinavia. The third generation uses prefabricated, pre-insulated pipes, which are directly buried into the ground and operates with lower temperatures, usually below 100 °C. A primary motivation for building these systems
was security of supply by improving the energy efficiency after the two oil crises led to disruption of the oil supply. Therefore those systems usually used coal, biomass and waste as energy sources, while oil was mostly neglected. In some systems,
geothermal energy and solar energy are also used in the energy mix.[4] For example Paris has been using geothermal heating from a 55-70 °C source 1–2 km below the surface since the 1970s for domestic heating.[5]

Fourth Generation

https://en.wikipedia.org/wiki/District_heating 1/8
3/20/2019 District heating - Wikipedia

Currently, the 4th generation is being developed,[4] with the transition to 4th generation already in process in Denmark.[6] The 4th generation is designed to combat climate change and integrate high shares of variable renewable energy into the district
heating by providing high flexibility to the electricity system.[4]

According to the review by Lund et al.[4] those systems have to have the following abilities:

"1. Ability to supply low-temperature district heating for space heating and domestic hot water (DHW) to existing buildings, energy-renovated existing buildings and new low-energy buildings."
"2. Ability to distribute heat in networks with low grid losses."
"3. Ability to recycle heat from low-temperature sources and integrate renewable heat sources such as solar and geothermal heat."
"4. Ability to be an integrated part of smart energy systems (i.e. integrated smart electricity, gas, fluid and thermal grids) including being an integrated part of 4th Generation District Cooling systems."
"5. Ability to ensure suitable planning, cost and motivation structures in relation to the operation as well as to strategic investments related to the transformation into future sustainable energy systems".
Compared to the previous generations the temperature levels have been reduced to increase the energy efficiency of the system, with supply side temperatures of 70 °C and lower. Potential heat sources are waste heat from industry, CHP plants burning
waste, biomass power plants, geothermal and solar thermal energy (central solar heating), large scale heat pumps, waste heat from cooling purposes and data centers and other sustainable energy sources. With those energy sources and large scale thermal
energy storage, including seasonal thermal energy storage, 4th generation district heating systems are expected to provide flexibility for balancing wind and solar power generation, for example by using heat pumps to integrate surplus power as heat when
there is much wind energy or providing electricity by biomass plants when back-up power is needed.[4] Therefore, large scale heat pumps are regarded as a key technology for smart energy systems with high shares of renewable energy up to 100% and
advanced 4th generation district heating systems.[7][4][8]

Fifth Generation
A fifth generation heat network distributes heat at near ambient ground temperature: this minimizes heat losses to the ground and reduces the need for extensive insulation. Each building on the network uses a heat pump in its own plant room to extract
heat from the ambient circuit when it needs heat, and uses the same heat pump in reverse to reject heat when it needs cooling. This allows waste heat from cooling to be recycled to those buildings which need heating on a "Heat Sharing Network".[9] The
overall temperature within the ambient circuit is controlled by heat exchange with an aquifer or another water source to remain within a temperature range from 10°C to 25°C.

A modern building with a low temperature internal heat distribution system can install an efficient heat pump delivering heat output at 45°C. An older building with a higher temperature internal distribution system like radiators will require a high
temperature heat pump to deliver heat output.

Network piping for ambient ground temperature networks is less expensive to install than earlier generations as it does not need heavy insulation for the piping circuits and minimizes heat losses to the ground. All buildings on the network are required to
install and maintain individual heat pump systems to meet their heating and cooling temperature needs, each with capacity to satisfy its own peak demand.

A fifth generation network ("Balanced Energy Network", BEN) was installed in 2016 at two large buildings of the London South Bank University as a research and development project.[10][11].

Heat generation
Heat sources in use for various district heating systems include: power plants designed for combined heat and power (CHP, also called co-generation), including both combustion and nuclear power plants; and simple combustion of a fossil fuel or
biomass; geothermal heat; solar heat; industrial heat pumps which extract heat from seawater, river or lake water, sewage, or waste heat from industrial processes.

District heat from combined heat and power or simple combustion


The core element of many district heating systems is a heat-only boiler station. Additionally a cogeneration plant (also called combined heat and power, CHP) is often added in parallel with the boilers. Both have in common that they are typically based on
combustion of primary energy carriers. The difference between the two systems is that, in a cogeneration plant, heat and electricity are generated simultaneously, whereas in heat-only boiler stations only heat is generated.

In the case of a fossil fueled cogeneration plant, the heat output is typically sized to meet half of the peak winter heat load, but over the year will provide 90% of the heat supplied. Much of the heat produced in summer will generally be wasted. The boiler
capacity will be able to meet the entire heat demand unaided and can cover for breakdowns in the cogeneration plant. It is not economic to size the cogeneration plant alone to be able to meet the full heat load. In the New York City steam system, that is
around 2.5 GW.[12][13] Germany has the largest amount of CHP in Europe.[14]

The combination of cogeneration and district heating is very energy efficient in economic terms, but does emit CO2 and NO2 on-site. A simple thermal power station can be 20–35% efficient,[15] whereas a more advanced facility with the ability to recover
waste heat can reach total energy efficiency of nearly 80%.[15] Some may approach 100% based on the lower heating value by condensing the flue gas as well.[16]

Waste heat from nuclear power plants is sometimes used for district heating. The principles for a conventional combination of cogeneration and district heating applies the same for nuclear as it does for a thermal power station. Russia has several
cogeneration nuclear plants which together provided 11.4 PJ of district heat in 2005. Russian nuclear district heating is planned to nearly triple within a decade as new plants are built.[17]

Other nuclear-powered heating from cogeneration plants are in Ukraine, the Czech Republic, Slovakia, Hungary, Bulgaria, and Switzerland, producing up to about 100 MW per power station. One use of nuclear heat generation was with the Ågesta
Nuclear Power Plant in Sweden closed in 1974.

In Switzerland, the Beznau Nuclear Power Plant provides heat to about 20,000 people.[18]

Geothermal-sourced district heat

History

Geothermal district heating was used in Pompeii, and in Chaudes-Aigues since the 14th Century.[19]

United States

Direct use geothermal district heating systems, which tap geothermal reservoirs and distribute the hot water to multiple buildings for a variety of uses, are uncommon in the United States, but have existed in America for over a century.

In 1890, the first wells were drilled to access a hot water resource outside of Boise, Idaho. In 1892, after routing the water to homes and businesses in the area via a wooden pipeline, the first geothermal district heating system was created.

As of a 2007 study,[20] there were 22 geothermal district heating systems (GDHS) in the United States. As of 2010, two of those systems have shut down.[21] The table below describes the 20 GDHS currently operational in America.

System Name City State Startup Year Number of Customers Capacity, MWt Annual Energy Generated, GWh/year System Temperature, °F System Temperature, °C
Warm Springs Water District Boise ID 1892 275 3.6 8.8 175 79
Oregon Institute of Technology Klamath Falls OR 1964 1 6.2 13.7 192 89
Midland Midland SD 1969 12 0.09 0.2 152 67
College of Southern Idaho Twin Falls ID 1980 1 6.34 14 100 38
Philip Philip SD 1980 7 2.5 5.2 151 66
Pagosa Springs Pagosa Springs CO 1982 22 5.1 4.8 146 63
Idaho Capital Mall Boise ID 1982 1 3.3 18.7 150 66
Elko Elko NV 1982 18 3.8 6.5 176 80
Boise City Boise ID 1983 58 31.2 19.4 170 77
Warren Estates Reno NV 1983 60 1.1 2.3 204 96
San Bernardino San Bernardino CA 1984 77 12.8 22 128 53
City of Klamath Falls Klamath Falls OR 1984 20 4.7 10.3 210 99
Manzanita Estates Reno NV 1986 102 3.6 21.2 204 95
Elko County School District Elko NV 1986 4 4.3 4.6 190 88
Gila Hot Springs Glenwood NM 1987 15 0.3 0.9 140 60
Fort Boise Veteran's Hospital Boise Boise ID 1988 1 1.8 3.5 161 72
Kanaka Rapids Ranch Buhl ID 1989 42 1.1 2.4 98 37
In Search Of Truth Community Canby CA 2003 1 0.5 1.2 185 85
Bluffdale Bluffdale UT 2003 1 1.98 4.3 175 79
Lakeview Lakeview OR 2005 1 2.44 3.8 206 97

Solar-sourced district heat


Use of solar heat for district heating has been increasing in Denmark and Germany[23] in recent years.[24] The systems usually include interseasonal thermal energy storage for a consistent heat output day to day and between summer and winter. Good
examples are in Vojens[25] at 50 MW, Dronninglund at 27 MW and Marstal at 13 MW in Denmark.[26][27] These systems have been incrementally expanded to supply 10% to 40% of their villages' annual space heating needs. The solar-thermal panels are
ground-mounted in fields.[28] The heat storage is pit storage, borehole cluster and the traditional water tank. In Alberta, Canada the Drake Landing Solar Community has achieved a world record 97% annual solar fraction for heating needs, using solar-
thermal panels on the garage roofs and thermal storage in a borehole cluster.[29][30]

Heat pumps for district heat


In Stockholm, the first heat pump was installed in 1977 to deliver district heating sourced from IBM servers. Today the installed capacity is about 660 MW heat, utilizing treated sewage water, sea water, district cooling, data centers and grocery stores as
heat sources.[2] Another example is the Drammen Fjernvarme District Heating project in Norway which produces 14 MW from water at just 8 °C, industrial heat pumps are demonstrated heat sources for district heating networks. Among the ways that
industrial heat pumps can be utilized are:

https://en.wikipedia.org/wiki/District_heating 2/8
3/20/2019 District heating - Wikipedia

1. As the primary base load source where water from a low grade source of heat, e.g. a river, fjord, data center, power station outfall, sewage treatment works outfall (all typically between 0 ˚C and 25 ˚C), is
boosted up to the network temperature of typically 60 ˚C to 90 ˚C using heat pumps. These devices, although consuming electricity, will transfer a heat output three to six times larger than the amount of
electricity consumed. An example of a district system using a heat pump to source heat from raw sewage is in Oslo, Norway that has a heat output of 18 MW(thermal).[31]
2. As a means of recovering heat from the cooling loop of a power plant to increase either the level of flue gas heat recovery (as the district heating plant return pipe is now cooled by the heat pump) or by
cooling the closed steam loop and artificially lowering the condensing pressure and thereby increasing the electricity generation efficiency.
3. As a means of cooling flue gas scrubbing working fluid (typically water) from 60 ˚C post-injection to 20 ˚C pre-injection temperatures. Heat is recovered using a heat pump and can be sold and injected into
the network side of the facility at a much higher temperature (e.g. about 80 ˚C).
4. Where the network has reached capacity, large individual load users can be decoupled from the hot feed pipe, say 80 ˚C and coupled to the return pipe, at e.g. 40 ˚C. By adding a heat pump locally to this
user, the 40 ˚C pipe is cooled further (the heat being delivered into the heat pump evaporator). The output from the heat pump is then a dedicated loop for the user at 40 ˚C to 70 ˚C. Therefore, the overall
network capacity has changed as the total temperature difference of the loop has varied from 80–40 ˚C to 80 ˚C–x (x being a value lower than 40 ˚C).
Central solar heating plant at
Concerns have existed about the use of hydroflurocarbons as the working fluid (refrigerant) for large heat pumps. Whilst leakage is not usually measured, it is generally reported to be relatively low, such as 1% Marstal, Denmark. It covers more
(compared to 25% for supermarket cooling systems). A 30-megawatt heatpump could therefore leak (annually) around 75 kg of R134a or other working fluid.[32] Given the high global warming potential of some than half of Marstal's heat
HFCs, this could equate to over 800,000 kilometres (500,000 mi) of car travel per year. consumption.[22]

However, recent technical advances allow the use of natural heat pump refrigerants that have very low global warming potential (GWP). CO2 refrigerant (R744, GWP=1) or ammonia (R717, GWP=0) also have
the benefit, depending on operating conditions, of resulting in higher heat pump efficiency than conventional refrigerants. An example is a 14 MW(thermal) district heating network in Drammen, Norway which is supplied by seawater-source heatpumps
that use R717 refrigerant, and has been operating since 2011. 90 °C water is delivered to the district loop (and returns at 65 °C). Heat is extracted from seawater (from 60-foot (18 m) depth) that is 8 to 9 °C all year round, giving an average coefficient of
performance (COP) of about 3.15. In the process the seawater is chilled to 4 °C; however, this resource is not utilized. In a district system where the chilled water could be utilized for air conditioning, the effective COP would be considerably higher.[32]

In the future, industrial heat pumps will be further de-carbonised by using, on one side, excess renewable electrical energy (otherwise spilled due to meeting of grid demand) from wind, solar, etc. and, on the other side, by making more of renewable heat
sources (lake and ocean heat, geothermal, etc.). Furthermore, higher efficiency can be expected through operation on the high voltage network.[33]

Excess renewable electrical energy for district heat


With European countries such as Germany and Denmark moving to very high levels (80% and 100% respectively by 2050) of renewable energy for all energy uses there will be increasing periods of excess production of renewable electrical energy. Storage
of this energy as potential electrical energy (e.g. pumped hydro) is very costly and reduces total round-trip efficiency. However, storing it as heat in district heating systems, for use in buildings where there is demand, is significantly less costly. Whilst the
quality of the electrical energy is degraded, high voltage grid MW sized heat pumps would maximise efficiency whilst not wasting excess renewable electricity.[34] Such coupling of the electricity sector with the heating sector (Power-to-X) is regarded as a
key factor for energy systems with high shares of renewable energy, because it allows storage to be used mainly in form of cheap heat storage. Therefore the usage of rather expensive electricity storage can be minimized, as the heat sector balances the
variable production of renewable energy sources with flexible loads and heat storage.[35] Stockholm at present has about 660 MW of heat pumps connected to its district heating system.[2]

Cold district heating


Heat pumps can also be used at the consumer-side instead of a substation, especially in so called cold district heating systems. These systems operate at ambient ground temperature (about 10 to 25 °C) and can be used both for heating and cooling. Hot
water and space heating is provided by heat pumps, which use the ambient groundwater as heat source. The system itself can be fed by various (low-temperature) heat sources including ambient heat, ambient water from rivers, lakes, sea or lagoons, and
waste heat from industrial or commercial sources.[36] This system is also called the 5th generation of district heating.[37]

Heat accumulators and storage


Increasingly large heat stores are being used with district heating networks to maximise efficiency and financial returns. This allows cogeneration units to be run at times of maximum electrical tariff, the
electrical production having much higher rates of return than heat production, whilst storing the excess heat production. It also allows solar heat to be collected in summer and redistributed off season in very
large but relatively low-cost in-ground insulated reservoirs or borehole systems. The expected heat loss at the 203,000m³ insulated pond in Vojens is about 8%.[25]

Heat distribution
After generation, the heat is distributed to the customer via a network of insulated pipes. District heating systems consist of feed and return lines. Usually the pipes are installed underground but there are also
systems with overground pipes. Within the system heat storage units may be installed to even out peak load demands.

The common medium used for heat distribution is water or pressurized hot water, but steam is also used. The advantage of steam is that in addition to heating purposes it can be used in industrial processes due District heating accumulation tower
to its higher temperature. The disadvantage of steam is a higher heat loss due to the high temperature. Also, the thermal efficiency of cogeneration plants is significantly lower if the cooling medium is high- from Theiss near Krems an der
Donau in Lower Austria with a
temperature steam, reducing electric power generation. Heat transfer oils are generally not used for district heating, although they have higher heat capacities than water, as they are expensive and have
thermal capacity of 2 gigawatt-hours
environmental issues.
(7.2 TJ)

At customer level the heat network is usually connected to the central heating system of the dwellings via heat exchangers (heat substations): the working fluids of both networks (generally water or steam) do not
mix. However, direct connection is used in the Odense system.

Typical annual loss of thermal energy through distribution is around 10%, as seen in Norway's district heating network.[38]

Heat metering
The amount of heat provided to customers is often recorded with a heat meter to encourage conservation and maximize the number of customers which can be served, but such meters are expensive. Due to the
expense of heat metering, an alternative approach is simply to meter the water – water meters are much cheaper than heat meters, and have the advantage of encouraging consumers to extract as much heat as
possible, leading to a very low return temperature, which increases the efficiency of power generation. Underground tunnel for heat pipes
between Rigshospitalet and
Many systems were installed under a socialist economy (such as in the former Eastern Bloc) which lacked heat metering and means to adjust the heat delivery to each apartment.[39][40] This led to great Amagerværket in Denmark
inefficiencies – users had to simply open windows when too hot – wasting energy and minimising the numbers of connectable customers.[41]

Size of systems
District heating systems can vary in size. Some systems cover entire cities such as Stockholm or Flensburg, using a network of large 1000 mm diameter primary pipes linked to secondary pipes – 200 mm
diameter perhaps, which in turn link to tertiary pipes of perhaps 25 mm diameter which might connect to 10 to 50 houses.

Some district heating schemes might only be sized to meet the needs of a small village or area of a city in which case only the secondary and tertiary pipes will be needed.

Some schemes may be designed to serve only a limited number of dwellings – 20–50 – in which case only tertiary sized pipes are needed.

Pros and cons Insulated pipes to connect a new


building to University of Warwick's
District heating has various advantages compared to individual heating systems. Usually district heating is more energy efficient, due to simultaneous production of heat and electricity in combined heat and campus-wide combined heat and
power system
power generation plants. This has the added benefit of reducing carbon emissions.[42] The larger combustion units also have a more advanced flue gas cleaning than single boiler systems. In the case of surplus
heat from industries, district heating systems do not use additional fuel because they recover heat which would otherwise be dispersed to the environment.

District heating requires a long-term financial commitment that fits poorly with a focus on short-term returns on investment. Benefits to the community include avoided costs of energy through the use of surplus and
wasted heat energy, and reduced investment in individual household or building heating equipment. District heating networks, heat-only boiler stations, and cogeneration plants require high initial capital expenditure
and financing. Only if considered as long-term investments will these translate into profitable operations for the owners of district heating systems, or combined heat and power plant operators. District heating is less
attractive for areas with low population densities, as the investment per household is considerably higher. Also it is less attractive in areas of many small buildings; e.g. detached houses than in areas with a fewer larger
buildings; e.g. blocks of flats, because each connection to a single-family house is quite expensive.

Individual heating systems can be completely shutdown intermittently according to local heating demand which is not the case with a district heating system.

Ownership, monopoly issues and charging structures


In many cases large combined heat and power district heating schemes are owned by a single entity. This was typically the case in the old Eastern bloc countries. However, for many schemes, the ownership of the
cogeneration plant is separate from the heat using part.

Examples are Warsaw which has such split ownership with PGNiG Termika owning the cogeneration unit, the Veolia owning 85% of the heat distribution, the rest of the heat distribution is owned by municipality and
workers. Similarly all the large CHP/CH schemes in Denmark are of split ownership.

Sweden provides an alternative example where the heating market is deregulated. In Sweden it is most common that the ownership of the district heating network is not separated from the ownership of the cogeneration
plants, the district cooling network or the centralized heat pumps. There are also examples where the competition has spawned parallel networks and interconnected networks where multiple utilities cooperate.

In the United Kingdom there have been complaints that district heating companies have too much of a monopoly and are insufficiently regulated,[43] an issue the industry is aware of, and has taken steps to improve
consumer experience through the use of customer charters as set out by the Heat Trust. Some customers are taking legal action against the supplier for Misrepresentation & Unfair Trading, claiming district Heating is
not delivering the savings promised by many heat suppliers.[44]

District heating pipe in


National variation Tübingen, Germany

Since conditions from city to city differ, every district heating system is unique. In addition, nations have different access to primary energy carriers and so they have a different approach on how to address heating
markets within their borders.

Europe

https://en.wikipedia.org/wiki/District_heating 3/8
3/20/2019 District heating - Wikipedia

Since 1954, district heating has been promoted in Europe by Euroheat & Power. They have compiled an analysis of district heating and cooling markets in Europe within their Ecoheatcool project supported by the
European Commission. A separate study, entitled Heat Roadmap Europe, has indicated that district heating can reduce the price of energy in the European Union between now and 2050.[45] The legal framework in the
member states of the European Union is currently influenced by the EU's CHP Directive.

Cogeneration in Europe
The EU has actively incorporated cogeneration into its energy policy via the CHP Directive. In September 2008 at a hearing of the European Parliament's Urban Lodgment Intergroup, Energy Commissioner Andris
Piebalgs is quoted as saying, "security of supply really starts with energy efficiency."[46] Energy efficiency and cogeneration are recognized in the opening paragraphs of the European Union's Cogeneration Directive
2004/08/EC. This directive intends to support cogeneration and establish a method for calculating cogeneration abilities per country. The development of cogeneration has been very uneven over the years and has been
dominated throughout the last decades by national circumstances.

As a whole, the European Union currently generates 11% of its electricity using cogeneration, saving Europe an estimated 35 Mtoe per annum.[47] However, there are large differences between the member states, with
energy savings ranging from 2% to 60%. Europe has the three countries with the world's most intensive cogeneration economies: Denmark, the Netherlands and Finland.[48]

District heating substation


Other European countries are also making great efforts to increase their efficiency. Germany reports that over 50% of the country's total electricity demand could be provided through cogeneration. Germany set a target
with a thermal power of 700
to double its electricity cogeneration from 12.5% of the country's electricity to 25% by 2020 and has passed supporting legislation accordingly in "Federal Ministry of Economics and Technology", (BMWi), Germany,
kW which insulates the
August 2007. The UK is also actively supporting district heating. In the light of UK's goal to achieve an 80% reduction in carbon dioxide emissions by 2050, the government had set a target to source at least 15% of water circuit of the district
government electricity from CHP by 2010.[49] Other UK measures to encourage CHP growth are financial incentives, grant support, a greater regulatory framework, and government leadership and partnership. heating system and the
customer's central heating
According to the IEA 2008 modelling of cogeneration expansion for the G8 countries, expansion of cogeneration in France, Germany, Italy and the UK alone would effectively double the existing primary fuel savings by system
2030. This would increase Europe's savings from today's 155 TWh to 465 TWh in 2030. It would also result in a 16% to 29% increase in each country's total cogenerated electricity by 2030.

Governments are being assisted in their CHP endeavors by organizations like COGEN Europe who serve as an information hub for the most recent updates within Europe's energy policy. COGEN is Europe's umbrella organization representing the
interests of the cogeneration industry, users of the technology and promoting its benefits in the EU and the wider Europe. The association is backed by the key players in the industry including gas and electricity companies, ESCOs, equipment suppliers,
consultancies, national promotion organisations, financial and other service companies.

A 2016 EU energy strategy suggests increased use of district heating.[50]

Austria
The largest district heating system in Austria is in Vienna (Fernwärme Wien) – with many smaller systems distributed over the whole country.

District heating in Vienna is run by Wien Energie. In the business year of 2004/2005 a total of 5.163 GWh was sold, 1.602 GWh to 251.224 private apartments and houses and 3.561 GWh to 5211 major
customers. The three large municipal waste incinerators provide 22% of the total in producing 116 GWh electric power and 1.220 GWh heat. Waste heat from municipal power plants and large industrial plants
account for 72% of the total. The remaining 6% is produced by peak heating boilers from fossil fuel. A biomass-fired power plant has produced heat since 2006.

In the rest of Austria the newer district heating plants are constructed as biomass plants or as CHP-biomass plants like the biomass district heating of Mödling or the biomass district heating of Baden.

Most of the older fossil-fired district heating systems have a district heating accumulator, so that it is possible to produce the thermal district heating power only at that time where the electric power price is
The District Heating Power Plant
high.
Steyr is a renewable combined heat
and power plant in which wood
Bulgaria chips are used to generate power[51]

Bulgaria has district heating in around a dozen towns and cities. The largest system is in the capital Sofia, where there are four power plants (two CHPs and two boiler stations) providing heat to the majority of
the city. The system dates back to 1949.[6] (https://web.archive.org/web/20120119073404/http://www.toplo.bg/za_nas/istoria)

Czech Republic
The largest district heating system in the Czech Republic is in Prague owned and operated by Pražská teplárenská, serving 265,000 households and selling c. 13 PJ of heat annually. Most of the heat is actually produced as waste heat in 30 km distant
thermal power station in Mělník. There are many smaller central heating systems spread around the country[52] including waste heat usage, municipal waste incineration and heat plants.

Denmark
In Denmark district heating covers more than 64% of space heating and water heating.[53] In 2007, 80.5% of this heat was produced by combined heat and power plants. Heat recovered from waste incineration accounted for 20.4% of the total Danish
district heat production.[54] In 2013, Denmark imported 158,000 ton waste for incineration.[55] Most major cities in Denmark have big district heating networks, including transmission networks operating with up to 125 °C and 25 bar pressure and
distribution networks operating with up to 95 °C and between 6 and 10 bar pressure. The largest district heating system in Denmark is in the Copenhagen area operated by CTR I/S and VEKS I/S. In central Copenhagen, the CTR network serves 275,000
households (90-95% of the area's population) through a network of 54 km double district heating distribution pipes providing a peak capacity of 663 MW.[56] The consumer price of heat from CTR is approximately €49 per MWh plus taxes (2009).[57]

The Danish island of Samsø has three straw-fueled plants producing district heating.[58]

Finland
In Finland district heating accounts for about 50% of the total heating market,[59] 80% of which is produced by combined heat and power plants. Over 90% of apartment blocks, more than half of all terraced houses, and the bulk of public buildings and
business premises are connected to a district heating network. Natural gas is mostly used in the south-east gas pipeline network, imported coal is used in areas close to ports, and peat is used in northern areas where peat is a natural resource. Other
renewables, such as wood chips and other paper industry combustible by-products, are also used, as is the energy recovered by the incineration of municipal solid waste. Industrial units which generate heat as an industrial by-product may sell otherwise
waste heat to the network rather than release it into the environment. Excess heat and power from pulp mill recovery boilers is a significant source in mill towns. In some towns waste incineration can contribute as much as 8% of the district heating heat
requirement. Availability is 99.98% and disruptions, when they do occur, usually reduce temperatures by only a few degrees.

In Helsinki, an underground datacenter next to the President's palace releases excess heat into neighboring homes,[60] producing enough heat to heat approximately 500 large houses.[61]

Germany
In Germany district heating has a market share of around 14% in the residential buildings sector. The connected heat load is around 52,729 MW. The heat comes mainly from cogeneration plants (83%). Heat-only boilers supply 16% and 1% is surplus heat
from industry. The cogeneration plants use natural gas (42%), coal (39%), lignite (12%) and waste/others (7%) as fuel.[62]

The largest district heating network is located in Berlin whereas the highest diffusion of district heating occurs in Flensburg with around 90% market share. In Munich about 70% of the electricity produced comes from district heating plants.[63]

District heating has rather little legal framework in Germany. There is no law on it as most elements of district heating are regulated in governmental or regional orders. There is no governmental support for district heating networks but a law to support
cogeneration plants. As in the European Union the CHP Directive will come effective, this law probably needs some adjustment.

Greece
Greece has district heating mainly in the Province of Western Macedonia, Central Macedonia and the Peloponnese Province. The largest system is the city of Ptolemaida, where there are five power plants (thermal power stations or TPS in particular)
providing heat to the majority of the largest towns and cities of the area and some villages. The first small installation took place in Ptolemaida in 1960, offering heating to Proastio village of Eordaea using the TPS of Ptolemaida. Today District heating
installations are also available in Kozani, Ptolemaida, Amyntaio, Philotas, Serres and Megalopolis using nearby power plants. In Serres the power plant is a Hi-Efficiency CHP Plant using natural gas, while coal is the primary fuel for all other district
heating networks.

Hungary
According to the 2011 census there were 607,578 dwellings (15.5% of all) in Hungary with district heating, mostly panel flats in urban areas.[64] The largest district heating system located in Budapest, the municipality-
owned Főtáv Zrt. ("Metropolitan Teleheating Company") provides heat and piped hot water for 238,000 households and 7,000 companies.[65]

Iceland
With 95% of all housing (mostly in the capital of Reykjavík) enjoying district heating services – mainly from geothermal energy, Iceland is the country with the highest penetration of district heating.

Most of Iceland's district heating comes from three geothermal power plants, producing over 800 MWth:[66]

Svartsengi combined heat and power plant (CHP)


Nesjavellir CHP plant
Hellisheiði CHP plant
Geothermal borehole
outside the Reykjavik
Ireland
Power Station.
The Dublin Waste-to-Energy Plant will provide district heating for up to 50,000 homes in Poolbeg and surrounding areas.[67] Tralee in Co Kerry has a 1 MW district heating system providing heat to an apartment
complex, sheltered housing for the elderly, a library and over 100 individual houses. The system is fuelled by locally produced wood chip.[68]
In Glenstal Abbey in Co Limerick there exists a pond-based 150 kW heating system for a school.[69]

Italy
In Italy, district heating is used in some cities (Bergamo, Brescia, Cremona, Bolzano, Ferrara, Imola, Reggio Emilia, Terlan, Turin, Lodi, and now Milan). The district heating of Turin is the biggest of the country and it supplies 550.000 people (62% of the
whole city population).

https://en.wikipedia.org/wiki/District_heating 4/8
3/20/2019 District heating - Wikipedia

Netherlands
District heating is used in Rotterdam[70][71] and Amsterdam, with more expected as the government has mandated a transition away from natural gas for all homes in the country by 2050.[72]

Norway
In Norway district heating only constitutes approximately 2% of energy needs for heating. This is a very low number compared to similar countries. One of the main reasons district heating has a low penetration
in Norway is access to cheap hydro-based electricity, and 80% of private electricity consumption goes to heat rooms and water. However, there is district heating in the major cities.

Poland
A cogeneration thermal power plant
In 2009, 40% of Polish households used district heating, most of them in urban areas.[73] Heat is provided primarily by combined heat and power plants, most of which burn hard coal. The largest district in Ferrera Erbognone (PV), Italy
heating system is in Warsaw, owned and operated by Veolia Warszawa, distributing approx. 34 PJ annually.

Romania
The largest district heating system in Romania is in Bucharest. Owned and operated by RADET, it distributes approximately 24 PJ annually, serving 570 000 households. This corresponds to 68% of Bucharest's total domestic heat requirements (RADET
fulfills another 4% through single-building boiler systems, for a total of 72%).

Russia
In most Russian cities, district-level combined heat and power plants (ТЭЦ, теплоэлектроцентраль) produce more than 50% of the nation's electricity and simultaneously provide hot water for neighbouring city blocks. They mostly use coal and gas-
powered steam turbines for cogeneration of heat. Now, combined cycle gas turbines designs are beginning to be widely used as well.

Serbia
In Serbia, district heating is used throughout the main cities, particularly in the capital, Belgrade. The first district heating plant was built in 1961 as a means to provide effective heating to the newly built suburbs of Novi Beograd. Since then, numerous
plants have been built to heat the ever-growing city. They use natural gas as fuel, because it has less of an effect on the environment. The district heating system of Belgrade possesses 112 heat sources of 2,454 MW capacity, over 500 km of pipeline, and
4365 connection stations, providing district heating to 240,000 apartments and 7,500 office/commercial buildings of total floor area exceeding 17,000,000 square meters.

Sweden
Sweden has a long tradition for using district heating in urban areas. In 2015, about 60% of Sweden's houses (private and commercial) were heated by district heating, according to the Swedish association of district heating.[74] The city of Växjö reduced
its fossil fuel consumption by 30% between 1993 and 2006, and aimed for a 50% reduction by 2010. This was to be achieved largely by way of biomass fired teleheating.[75] Another example is the plant of Enköping, combining the use of short rotation
plantations both for fuel as well as for phytoremediation.[76]

47% of the heat generated in Swedish teleheating systems are produced with renewable bioenergy sources, as well as 16% in waste-to-energy plants, 7% is provided by heat pumps, 10% by flue-gas condensation and 6% by industrial waste heat recovery.
The remaining are mostly fossil fuels: oil (3%), natural gas (3%), peat (2%), and coal (1%).[77][78]

Because of the law banning traditional landfills,[79] waste is commonly used as a fuel.

United Kingdom
In the United Kingdom, district heating became popular after World War II, but on a restricted scale, to heat the large residential estates that replaced areas devastated by the Blitz. In 2013 there were 1,765
district heating schemes with 920 based in London alone.[80] In total around 210,000 homes and 1,700 businesses are supplied by heat networks in the UK.[81]

The Pimlico District Heating Undertaking (PDHU) first became operational in 1950 and continues to expand to this day. The PDHU once relied on waste heat from the now-disused Battersea Power Station on
the South side of the River Thames. It is still in operation, the water now being heated locally by a new energy centre which incorporates 3.1 MWe / 4.0 MWth of gas fired CHP engines and 3 × 8 MW gas-fired
boilers.

One of the United Kingdom's largest district heating schemes is EnviroEnergy in Nottingham. The plant initially built by Boots is now used to heat 4,600 homes, and a wide variety of business premises,
including the Concert Hall, the Nottingham Arena, the Victoria Baths, the Broadmarsh Shopping Centre, the Victoria Centre, and others. The heat source is a waste-to-energy incinerator. Scotland has several
district heating systems with the first in the UK being installed at Aviemore and others following at Lochgilphead, Fort William and Forfar.

Sheffield's district heating network was established in 1988 and is still expanding today. It saves an equivalent 21,000 plus tonnes of CO2 each year when compared to conventional sources of energy – electricity
from the national grid and heat generated by individual boilers. There are currently over 140 buildings connected to the district heating network. These include city landmarks such as the Sheffield City Hall, the
Lyceum Theatre, Sheffield University, Sheffield Hallam University, hospitals, shops, offices and leisure facilities plus 2,800 homes. More than 44 km of underground pipes deliver energy which is generated at
Sheffield Energy Recovery Facility. This converts 225,000 tonnes of waste into energy, producing up to 60 MWe of thermal energy and up to 19 MWe of electrical energy.
District heating accumulator tower
The Southampton District Energy Scheme was originally built to use just geothermal energy, but now also uses the heat from a gas fired CHP generator. It supplies heating and district cooling to many large and workshops on the Churchill
premises in the city, including the WestQuay shopping centre, the De Vere Grand Harbour hotel, the Royal South Hants Hospital, and several housing schemes. In the 1980s Southampton began utilising Gardens Estate, Pimlico, London.
combined heat and power district heating, taking advantage of geothermal heat "trapped" in the area. The geothermal heat provided by the well works in conjunction with the Combined Heat and Power scheme. This plant once used waste heat
piped from Battersea Power Station
Geothermal energy provides 15-20%, fuel oil 10%, and natural gas 70% of the total heat input for this scheme and the combined heat and power generators use conventional fuels to make electricity. "Waste heat"
on the other side of the River
from this process is recovered for distribution through the 11 km mains network.[5][82]
Thames. (January 2006)

Lerwick District Heating Scheme is of note because it is one of the few schemes where a completely new system was added to a previously existing small town.

ADE has an online map of district heating installations in the UK.[83] ADE estimates that 54 percent of energy used to produce electricity is being wasted via conventional power production, which relates to £9.5 billion ($US12.5 billion) per year.[84]

Spain
The largest district heating system in Spain is located in Soria.[85] It is called "Ciudad del Medio Ambiente" (Environmental Town) and will receive 41 MW from a biomass power plant.

North America
In North America, district heating systems fall into two general categories. Those that are owned by and serve the buildings of a single entity are considered institutional systems. All others fall into the commercial category.

Canada
District Heating is becoming a growing industry in Canadian cities, with many new systems being built in the last ten years. Some of the major systems in Canada include:

Calgary: ENMAX currently operates the Calgary Downtown District Energy Centre which provides heating to up to 10,000,000 square feet (930,000 m2) of new and existing residential and commercial buildings. The District Energy Centre began
operations in March 2010 providing heat to its first customer, the City of Calgary Municipal building.[86]
Hamilton, ON has a district heating and cooling system in the downtown core, operated by HCE Energy Inc.[87]
Montreal has a district heating and cooling system in the downtown core.
Toronto – Enwave provides district heating and cooling within the downtown core of Toronto, including deep lake cooling technology, which circulates cold water from Lake Ontario through heat exchangers to provide cooling for many buildings in the
city.
Surrey: Surrey City Energy owned by the city, provides district heating to the city's City Centre district.[88]
Vancouver:

Central Heat Distribution Ltd. Since 1968 operates a central heating plant in the downtown core of Vancouver, British Columbia. In addition to heating 180 buildings, the Central Heat Distribution network also drives a steam clock.
A large scale district heating system known as the Neighbourhood Energy Utility[89] in the South East False Creek area is in initial operations with natural gas boilers and serves the 2010 Olympic Village. The commissioning of an innovative
untreated sewage heat recovery system anticipated for January 2010 is expected to supply 70% of annual energy demands and reduce greenhouse gas emissions.
Windsor, Ontario has a district heating and cooling system in the downtown core.
Drake Landing, AB, is small in size (52 homes) but notable for having the only central solar heating system in North America.
London, Ontario and Charlottetown, PEI have district heating co-generation systems owned and operated by Veresen.[90]
Sudbury, Ontario has a district heating cogeneration system in its downtown core, as well as a standalone cogeneration plant for the Sudbury Regional Hospital. In addition, Naneff Gardens, a new residential subdivision off Donnelly Drive in the city's
Garson neighbourhood, features a geothermal district heating system using technology developed by a local company, Renewable Resource Recovery Corporation.[91]
Ottawa, contains a significant district heating and cooling system serving the large number of federal government buildings in the city. The system loop contains nearly a million gallons of chilled or heated water at any time.
Cornwall, Ontario operates a district heating system which serves a number of city buildings and schools.
Markham, Ontario: Markham District Energy operates several district heating sites:

Warden Energy Centre (c. 2000), Clegg Energy Centre and Birchmount Energy Centre serving customers in the Markham Centre area
Bur Oak Energy Centre (c. 2012) serving customers in the Cornell Centre area

Many Canadian universities operate central campus heating plants.

United States
The Holly Steam Combination Company was the first steam heating company to commercially distribute district heating from a central steam heating system.

Consolidated Edison of New York (Con Ed) operates the New York City steam system, the largest commercial district heating system in the United States.[92] The system has operated continuously since March 3, 1882 and serves Manhattan Island
from the Battery through 96th Street.[93] In addition to providing space- and water-heating, steam from the system is used in numerous restaurants for food preparation, for process heat in laundries and dry cleaners, and to power absorption chillers
for air conditioning.

https://en.wikipedia.org/wiki/District_heating 5/8
3/20/2019 District heating - Wikipedia

The city of Milwaukee, Wisconsin has been using district heating for its central business district since the Valley Power Plant commenced operations in 1968.[7] (https://www.we-energies.com/home/projects/vapp.htm) Amazingly, the air quality in the
immediate vicinity of the plant, based on the sensor located on César Chavez Drive, qualifies as the best in Southeastern Wisconsin, at least with regard to ozone concentration. The recent (2012) conversion of the plant, which changed the fuel input from
coal to natural gas, is expected to further improve air quality at both the local César Chavez sensor as well as Antarctic sensors [8] (http://www.jsonline.com/business/we-energies-converting-valley-power-plant-j56hi5n-166616006.html). Interesting to
note about Wisconsin power plants is their dual use as breeding grounds for peregrines [9] (http://we-energies.com/environmental/protect_wildlife.htm).

On July 18, 2007, one person was killed and numerous others injured when a steam pipe exploded on 41st Street at Lexington.[94] On August 19, 1989, three people were killed in an explosion in Gramercy Park.[95]
Denver's district steam system is the oldest continuously operated commercial district heating system in the world. It began service November 5, 1880 and continues to serve 135 customers.[96] The system is partially powered by the Xcel Energy
Zuni Cogeneration Station, which was originally built in 1900.[97]
NRG Energy operates district systems in the cities of San Francisco, Harrisburg, Minneapolis, Omaha, Pittsburgh, and San Diego.[98]
Seattle Steam Company operates a district system in Seattle.
Hamtramck Energy Services (HES) operates a district system in Detroit that started operation at the Willis Avenue Station in 1903.
Lansing Board of Water and Light, a municipal utility system in Lansing, Michigan operates a heated and chilled water system from their existing coal plant. They have announced their new natural gas cogeneration plant will continue to provide this
service.
Cleveland Thermal operates a district steam (since 1894) from the Canal Road plant near The Flats and district cooling system (since 1993) from Hamilton Avenue plant on the bluffs east of downtown.
Fort Chicago Energy Partners L.P. operate district heating/co-generation plants in Ripon, California and San Gabriel, California.[99]
Veolia Energy, a successor of the 1887 Boston Heating Company,[100] operates a 26-mile (42 km) district system in Boston and Cambridge, Massachusetts, and also operates systems in Philadelphia PA, Baltimore MD, Kansas City MO, Tulsa OK,
Houston TX and other cities.
District Energy St. Paul operates the largest hot water district heating system in North America and generates the majority of its energy from an adjacent biomass-fueled combined heat and power plant. In March 2011, a 1 MWh thermal solar array
was integrated into the system, consisting of 144 20' x 8' solar panels installed on the roof of a customer building, RiverCentre.
The California Department of General Services runs a central plant providing district heating to four million square feet in 23 state-owned buildings, including the State Capitol, using high-pressure steam boilers.[101]
District heating is also used on many college campuses, often in combination with district cooling and electricity generation. Colleges using district heating include the University of Texas at Austin; Rice University;[102] Brigham Young University;[103]
Georgetown University;[104] Cornell University,[105] which also employs deep water source cooling using the waters of nearby Cayuga Lake;[106] Purdue University;[107] University of Notre Dame; Michigan State University; Eastern Michigan
University;[108] Case Western Reserve University; Iowa State University; University of Delaware;[109] University of Maryland, College Park, University of Wisconsin–Madison,[110] and several campuses of the University of California.[111] MIT installed a
cogeneration system in 1995 that provides electricity, heating and cooling to 80% of its campus buildings.[112] The University of New Hampshire has a cogeneration plant run on methane from an adjacent landfill, providing the University with 100% of its
heat and power needs without burning oil or natural gas.[113] North Dakota State University (NDSU) in Fargo, North Dakota has used district heating for over a century from their coal-fired heating plant.[114]

Asia

Japan
87 district heating enterprises are operating in Japan, serving 148 districts.[115]

Many companies operate district cogeneration facilities that provide steam and/or hot water to many of the office buildings. Also, most operators in the Greater Tokyo serve district cooling.

China
In southern China, there are nearly no district heating systems. In northern China, district heating systems are common. Most district heating system which are just for heating instead of CHP use hard coal. For air pollution in China has become quite
serious, many cities gradually are now using natural gas rather than coal in district heating system. There is also some amount of geothermal heating and sea heat pump systems.

In February 2019, China's State Power Investment Corporation (SPIC) signed a cooperation agreement with the Baishan municipal government in Jilin province for the Baishan Nuclear Energy Heating Demonstration Project, which would use a China
National Nuclear Corporation DHR-400 (District Heating Reactor 400 MWt).[116][117] Building cost is 1.5 billion yuan ($230 million), taking three years to build.[118]

Market penetration
Penetration of district heating (DH) into the heat market varies by country. Penetration is influenced by different factors, including environmental conditions, availability of heat sources, economics, and economic and legal framework.

In the year 2000 the percentage of houses supplied by district heat in some European countries was as follows:

Country Penetration (2000)[119]


Iceland 95%

Denmark 64.4% (2017)[53]


Estonia 52%
Poland 52%
Sweden 50%
Czech Rep. 49%
Finland 49%
Slovakia 40%

Russia 35%[120]

Germany 22% (2014)[121]


Hungary 16%
Austria 12.5%

France 7.7% (2017)[122]


Netherlands 3%
UK 2%

In Iceland the prevailing positive influence on DH is availability of easily captured geothermal heat. In most Eastern European countries, energy planning included development of cogeneration and district heating. Negative influence in the Netherlands
and UK can be attributed partially to milder climate, along with competition from natural gas. The tax on domestic gas prices in the UK is a third of that in France and a fifth of that in Germany.

See also
District cooling
Central solar heating
CHP Directive
Geothermal heating
Lists of public utilities
List of district heating systems
New York City steam system
Public utility
Thermal energy storage
Deep lake water cooling
Energy policy of the European Union
Relative cost of electricity generated by different sources
Cogeneration
Alchevsk district heating disaster (2006)

Footnotes
1. "Carbon footprints of various sources of heat – CHPDH comes out lowest | 5. "Structure" (https://web.archive.org/web/20061218081732/http://www.bbm.m 11. "About the BEN Project" (http://www.lsbu.ac.uk/research/centres-groups/sites/
Claverton Group" (http://www.claverton-energy.com/carbon-footprints-of-vario e.uk/portsdown/PH_450_Energy.htm). Archived from the original (http://www.b ben-project/about).
us-sources-of-heat-chpdh-comes-out-lowest.html). Claverton-energy.com. bm.me.uk/portsdown/PH_450_Energy.htm) on 2006-12-18. 080304 12. "Newsroom: Steam" (http://www.coned.com/newsroom/energysystems_stea
Retrieved 2011-09-25. bbm.me.uk m.asp). ConEdison. Retrieved 2007-07-20.
2. Levihn, Fabian (2017). "CHP and heat pumps to balance renewable power 6. Yang, Xiaochen; et al. (2016). "Energy, economy and exergy evaluations of 13. Bevelhymer, Carl (2003-11-10). "Steam" (https://web.archive.org/web/200708
production: Lessons from the district heating network in Stockholm" (http://ww the solutions for supplying domestic hot water from low-temperature district 13013416/http://www.gothamgazette.com/article/issueoftheweek/20031110/20
w.sciencedirect.com/science/article/pii/S036054421730124X). Energy. heating in Denmark". Energy Conversion and Management. 122: 142–152. 0/674). Gotham Gazette. Archived from the original (http://www.gothamgazett
doi:10.1016/j.energy.2017.01.118 (https://doi.org/10.1016%2Fj.energy.2017.0 doi:10.1016/j.enconman.2016.05.057 (https://doi.org/10.1016%2Fj.enconman. e.com/article/issueoftheweek/20031110/200/674) on 2007-08-13. Retrieved
1.118). Retrieved 2017-03-15. 2016.05.057). 2007-07-20.
3. Mazhar, Abdul Rehman; et al. (2018). "a state of art review on district heating 7. David, Andrei; et al. (2018). "Heat Roadmap Europe: Large-Scale Electric 14. What is cogeneration? (http://www.cogeneurope.eu/what-is-cogeneration_19.
systems". Renewable and Sustainable Energy Reviews. 96: 420–439. Heat Pumps in District Heating Systems". Energies. 10: 578. html) COGEN Europe, 2015
doi:10.1016/j.rser.2018.08.005 doi:10.3390/en10040578 (https://doi.org/10.3390%2Fen10040578).
15. "DOE – Fossil Energy: How Turbine Power Plants Work" (https://web.archive.
(https://doi.org/10.1016%2Fj.rser.2018.08.005). 8. Sayegh, M.A.; et al. (2018). "Heat pump placement, connection and org/web/20110812012523/http://fossil.energy.gov/programs/powersystems/tur
4. Lund, Henrik; et al. (2014). "4th Generation District Heating (4GDH): operational modes in European district heating". Energy and Buildings. 166: bines/turbines_howitworks.html). Fossil.energy.gov. Archived from the original
Integrating smart thermal grids into future sustainable energy systems". 122–144. doi:10.1016/j.enbuild.2018.02.006 (https://doi.org/10.1016%2Fj.enb (http://fossil.energy.gov/programs/powersystems/turbines/turbines_howitwork
Energy. 68: 1–11. doi:10.1016/j.energy.2014.02.089 (https://doi.org/10.1016% uild.2018.02.006). s.html) on August 12, 2011. Retrieved 2011-09-25.
2Fj.energy.2014.02.089). 9. "Heat Sharing Network" (https://www.icax.co.uk/Heat_Sharing.html).
10. "Balanced Energy Network" (https://www.benuk.net/index.html).

https://en.wikipedia.org/wiki/District_heating 6/8
3/20/2019 District heating - Wikipedia

16. "Waste-to-Energy CHP Amager Bakke Copenhagen" (https://stateofgreen.co 45. Connolly, David; Mathiesen, Brian Vad; Østergaard, Poul Alberg; Möller, 73. "Zużycie energii w gospodarstwach domowych w 2009 r." (http://www.stat.go
m/en/profiles/ramboll/solutions/waste-to-energy-chp-amager-bakke-copenhag Bernd; Nielsen, Steffen; Lund, Henrik; Persson, Urban; Werner, Sven; v.pl/cps/rde/xbcr/gus/SE_zuzycie_energii_gosp_dom_2009.pdf) [Energy
en). Retrieved 2015-03-09. Grözinger, Jan; Boermans, Thomas; Bosquet, Michelle; Trier, Daniel (27 May consumption in households in 2009] (PDF) (in Polish). Główny Urząd
17. "Nuclear Power in Russia" (http://www.world-nuclear.org/info/inf45.html). 2013). "Heat Roadmap Europe 2: Second Pre-Study for the EU27" (http://vbn. Statystyczny. 2012-05-28. Retrieved 2013-01-25.
World-nuclear.org. 2011-09-21. Retrieved 2011-09-25. aau.dk/en/publications/heat-roadmap-europe-2050(306a5052-a882-4af9-a5d 74. [1] (http://www.svenskfjarrvarme.se/Statistik--Pris/) Archived (https://web.archi
a-87efa36efeaa).html). Department of Development and Planning, Aalborg ve.org/web/20120418005915/http://www.svenskfjarrvarme.se/Statistik--Pris/)
18. SUGIYAMA KEN'ICHIRO (Hokkaido Univ.) et al.
University. Retrieved 18 March 2018 – via vbn.aau.dk. 2012-04-18 at the Wayback Machine Svensk Fjärrvärme
/000020060706A0175205.php Nuclear District Heating: The Swiss
Experience (http://sciencelinks.jp/j-east/article/200607) 46. "Energy Efficiency Industrial Forum Position Paper: energy efficiency – a vital 75. [2] (http://www.vaxjo.se/Kommun--politik/Om-Vaxjo-/Internationellt/Other-lang
component of energy security" (http://www.cogeneurope.eu/Downloadables/P uages/Engelska--English1/Sustainable-development/Fossil-Fuel-Free-Vaxjo/)
19. Bloomquist, R. Gordon (2001). Geothermal District Energy System Analysis,
ublications/230908_Energy_Efficiency_Industrial_Forum_Security_of_Supply. Municipality of Växjö
Design, and Development (http://www.geothermal-energy.org/pdf/IGAstandar
pdf) (PDF).
d/ISS/2001Romania/bloomquist_dh.pdf) (PDF). International Summer School. 76. Mola-Yudego, B; Pelkonen, P. (2011). "Pulling effects of district heating plants
International Geothermal Association. p. 213(1). Retrieved November 28, 47. "COGEN Europe News" (https://web.archive.org/web/20090101121334/http:// on the adoption and spread of willow plantations for biomass: The power plant
2015. Lay summary (https://pangea.stanford.edu/ERE/db/IGAstandard/record www.cogeneurope.eu/news.htm). Archived from the original (http://www.coge In Enköping (Sweden)" (http://www.sciencedirect.com/science/article/pii/S096
_detail.php?id=5313) – Stanford University. "During Roman times, warm neurope.eu/news.htm) on 2009-01-01. 195341100184X). Biomass and Bioenergy. 35 (7): 2986–2992.
water was circulated through open trenches to provide heating for buildings 48. "COGEN Europe: Cogeneration in the European Union's Energy Supply doi:10.1016/j.biombioe.2011.03.040 (https://doi.org/10.1016%2Fj.biombioe.20
and baths in Pompeii." Security" (http://www.cogeneurope.eu/Downloadables/Publications/Cogenerat 11.03.040). Retrieved 2012-10-14.
20. Thorsteinsson, Hildigunnur. "U.S. Geothermal District Heating: Barriers and ion_Europe_Draft_paper_on_Security_of_Supply_in_EU_energy_policy.pdf) 77. [3] (http://www.svenskfjarrvarme.se/Statistik--Pris/Fjarrvarme/Energitillforsel/)
Enablers" (https://web.archive.org/web/20140809070925/http://dspace.mit.ed (PDF). Archived (https://web.archive.org/web/20111016160142/http://www.svenskfjar
u/bitstream/handle/1721.1/42932/251518357.pdf) (PDF). Archived from the 49. "DEFRA Action in the UK – Combined Heat and Power" (https://web.archive.o rvarme.se/Statistik--Pris/Fjarrvarme/Energitillforsel/) 2011-10-16 at the
original (http://dspace.mit.edu/bitstream/handle/1721.1/42932/251518357.pdf) rg/web/20100612100647/http://www.defra.gov.uk/environment/climatechange/ Wayback Machine Svensk Fjärrvärme
(PDF) on 9 August 2014. Retrieved 25 July 2014. uk/energy/chp/index.htm). Archived from the original (http://www.defra.gov.uk/ 78. https://www.energiforetagen.se/globalassets/energiforetagen/statistik/fjarrvarme/
21. Lund, John. "The United States of America Country Update 2010" (https://pan environment/climatechange/uk/energy/chp/index.htm) on 2010-06-12. energi/branslemix-och-tillford-energi-med-tabell-2016.pdf?
gea.stanford.edu/ERE/pdf/IGAstandard/SGW/2010/lund.pdf) (PDF). Retrieved 50. https://ec.europa.eu/transparency/regdoc/rep/1/2016/EN/1-2016-51-EN-F1- v=VmMpJ_ho1Dn_JJS3MAJoIJOmb2w
25 July 2014. 1.PDF 79. J.Wawrzynczyk; M. Recktenwald; O. Norrlöw; E. Szwajcer Dey (March 2008).
22. Thomas Pauschinger, Thomas Schmidt: Solar unterstützte Kraft-Wärme- 51. Steyr, Fernwärme. "Bioenergie Steyr" (http://www.fernwaermesteyr.at/waerme "The role of cation-binding agents and enzymes in solubilisation of sludge" (ht
Kopplung mit saisonalem Wärmespeicher. In: Euroheat & Power, Mai 2013. _steyr/page/790213410858496064_790686873558106026~79068675383589 tp://www.bvsde.paho.org/bvsaar/cdlodos/pdf/theroleofcation519.pdf) (PDF).
23. Schmidt T., Mangold D. (2013). Large-scale thermal energy storage – Status 2434_790686753835892434,de.html). www.fernwaermesteyr.at. Retrieved Water Research. 42 (6, 7): 1555–1562. doi:10.1016/j.watres.2007.11.004 (htt
quo and perspectives (http://www.solar-district-heating.eu/LinkClick.aspx?fileti 18 March 2018. ps://doi.org/10.1016%2Fj.watres.2007.11.004). Retrieved 16 April 2013.
cket=4VeN0WSc5Pk%3d&portalid=0) Archived (https://web.archive.org/web/2 52. www.tscr.cz, Teplárenské sdružení České republiky -. "Teplárenské sdružení 80. "Summary evidence on District Heating Networks in the UK" (https://www.gov.
0161018073544/http://solar-district-heating.eu/LinkClick.aspx?fileticket=4VeN ČR - sdružuje teplárny a podnikatele v teplárenství a energetice" (http://www.t uk/government/uploads/system/uploads/attachment_data/file/212565/summar
0WSc5Pk%3d&portalid=0) 2016-10-18 at the Wayback Machine. First scr.cz). www.tscr.cz. Retrieved 18 March 2018. y_evidence_district_heating_networks_uk.pdf) (PDF). DECC.
international SDH Conference, Malmö, SE, 9-10th April 2013. Powerpoint. 53. Dansk Fjernvarme (12 July 2017). "Statistics about District Heating" (https://w 81. "The Future of Heating : Meeting the Challenge" (https://www.gov.uk/governm
24. Wittrup, Sanne (23 October 2015). "Fjernvarmeværker går fra naturgas til sol" ww.danskfjernvarme.dk/english/statistics). www.danskfjernvarme.dk. ent/uploads/system/uploads/attachment_data/file/190149/16_04-DECC-The_
(http://ing.dk/artikel/fjernvarmevaerker-skifter-naturgassen-ud-med-sol-17965 Retrieved 9 October 2018. Future_of_Heating_Accessible-10.pdf) (PDF). DECC.
9). Ingeniøren. 54. Danish Energy Statistics 2007 (https://wayback.archive-it.org/all/20110310035 82. "Geothermie district heating scheme Southampton United Kingdom" (http://w
25. Wittrup, Sanne (14 June 2015). "Verdens største damvarmelager indviet i 158/http://www.ens.dk/graphics/UK_Facts_Figures/Statistics/yearly_statistics/ ww.energie-cites.org/db/southampton_140_en.pdf) (PDF). 080304 energie-
Vojens" (https://web.archive.org/web/20151019125824/http://ing.dk/artikel/ver 2007/energy%20statistics%202007%20uk.pdf) by the Danish Ministry of cites.org
dens-stoerste-damvarmelager-indviet-i-vojens-176776). Ingeniøren. Archived Energy (in Danish). 83. "District Heating Installation Map" (http://www.theade.co.uk/district-heating-ins
from the original (http://ing.dk/artikel/verdens-stoerste-damvarmelager-indviet- 55. Klimaråd: Affaldsimport vil belaste dansk CO2-regnskab (http://www.danskfjer tallation-map_790.html). ADE.
i-vojens-176776) on 2015-10-19. Retrieved 2015-11-01. nvarme.dk/nyheder/presseklip/151127klimaraad-affaldsimport-vil-belaste-dan 84. Lambert, Kirsty (9 November 2017). "What a Waste! The Big Problem of Heat
26. Holm L. (2012). Long Term Experiences with Solar District Heating in sk-co2regnskab) Archived (https://web.archive.org/web/20151128144041/htt Loss in UK Cities" (http://www.renewableenergyworld.com/articles/2017/11/wh
Denmark (http://www.euroheat.org/Admin/Public/DWSDownload.aspx?File=% p://www.danskfjernvarme.dk/nyheder/presseklip/151127klimaraad-affaldsimpo at-a-waste-the-big-problem-of-heat-loss-in-uk-cities.html).
2fFiles%2fFiler%2fPresentations%2f20120618-22_EUSEW%2f120619_EUS rt-vil-belaste-dansk-co2regnskab) 2015-11-28 at the Wayback Machine 27 www.renewableenergyworld.com. Retrieved 12 November 2017.
EW_3+-+Holm+brussel+juni+2012.pdf). European Sustainable Energy Week, November 2015.
85. "NOTICIAS – Bioenergy International España: revista especializada en
Brussels. 18–22 June 2012. Powerpoint. 56. Environmentally Friendly District Heating to Greater Copenhagen (http://www. bioenergía" (https://web.archive.org/web/20110910155209/http://www.bioener
27. Current data on Danish solar heat plants (http://www.solvarmedata.dk/index.a ctr.dk/images/publikationer/3folder2006.pdf) Archived (https://web.archive.org/ gyinternational.es/noticias/News/show/el-mayor-district-heating-de-espana-se
sp?secid=228) (click Vojens in South-West Denmark, then "About the plant") web/20071129121423/http://www.ctr.dk/images/publikationer/3folder2006.pdf) -construye-en-soria-383). Bioenergyinternational.es. 2011-01-18. Archived
28. Dalenbäck, J-O (2012). Large-Scale Solar Heating: State of the Art (http://ww November 29, 2007, at the Wayback Machine, publication by CTR I/S (http:// from the original (http://www.bioenergyinternational.es/noticias/News/show/el-
w.euroheat.org/Admin/Public/DWSDownload.aspx?File=%2fFiles%2fFiler%2f www.ctr.dk) (2006) mayor-district-heating-de-espana-se-construye-en-soria-383) on 2011-09-10.
Presentations%2f20120618-22_EUSEW%2f120619_EUSEW_2+-+Pres-Zero 57. Prisen på Fjernvarme (http://www.ke.dk/portal/page/portal/Privat/Varme/Prise Retrieved 2011-09-25.
City-Brussels-SDH-JOD-19june2012.pdf). Presentation at European n_paa_fjernvarme?page=221) Archived (https://web.archive.org/web/2011071 86. "ENMAX District Energy Centre" (https://www.enmax.com/generation-wires/ge
Sustainable Energy Week, 18–22 June 2012, Brussels, Belgium. 9131304/http://www.ke.dk/portal/page/portal/Privat/Varme/Prisen_paa_fjernva neration/district-energy-centre). ENMAX.com. Retrieved 2015-09-25.
29. Wong B., Thornton J. (2013). Integrating Solar & Heat Pumps (http://www.geo rme?page=221) July 19, 2011, at the Wayback Machine, price list from the
87. "HCE Energy Inc" (http://www.hamiltonce.com). hamiltonce.com. Retrieved
-exchange.ca/en/UserAttachments/flex1304_5-%20SAIC-%20Bill%20Wong% Danish homepage of a Copenhagen district heating provider Københavns
2015-12-18.
202013%20-%20Integrating%20Solar%20and%20Heat%20Pumps.pdf). Energi (http://www.ke.dk) Archived (https://web.archive.org/web/20040611164
451/http://www.ke.dk/) June 11, 2004, at the Wayback Machine 88. Reid, Amy (November 30, 2017). "An exclusive look at Surrey's expanding
Renewable Heat Workshop. (Powerpoint)
district energy system" (https://www.surreynowleader.com/news/video-an-excl
30. Natural Resources Canada, 2012. Canadian Solar Community Sets New 58. "Network - DAC" (http://www.dac.dk/en/dac-cities/sustainable-cities/all-cases/
usive-look-at-surreys-expanding-district-energy-system/). Surrey Now-Leader.
World Record for Energy Efficiency and Innovation (http://www.nrcan.gc.ca/m energy/samsoe-a-role-model-in-self-sufficiency/). dac.dk. Retrieved 18 March
Retrieved January 28, 2018.
edia-room/news-release/2012/6586). 5 Oct. 2012. 2018.
89. "Neighbourhood Energy Utility" (http://vancouver.ca/sustainability/building_ne
31. Pedersen, S. & Stene, J. (2006). 18 MW heat pump system in Norway utilises 59. District heating in Finland (http://www.energia.fi/en/districtheating/districtheatin
u.htm). Vancouver.ca. Retrieved 2011-09-25.
untreated sewage as heat source (http://www.heatpumpcentre.org/en/newslett g) Archived (https://web.archive.org/web/20110722000506/http://www.energi
a.fi/en/districtheating/districtheating) July 22, 2011, at the Wayback Machine 90. "Archived copy" (https://web.archive.org/web/20130921060457/http://www.ver
er/previous/Documents/HPC-news_4_2006.htm). IEA Heat Pump Centre
eseninc.com/our-business/power/district-energy/). Archived from the original
Newsletter, 24:4, 37–38. 60. "In Helsinki" (http://www.scientificamerican.com/article.cfm?id=data-center-un
(http://www.vereseninc.com/our-business/power/district-energy/) on 2013-09-
32. Hoffman, & Pearson, D. 2011. Ammonia heat pumps for district heating in der-helsinki-to-warm-2010-03). Scientificamerican.com. Retrieved
21. Retrieved 2013-09-20.
Norway 7 – a case study (http://www.ammonia21.com/web/assets/link/Hoffma 2011-09-25.
91. "New geothermal technology could cut energy costs" (http://www.northernlife.
n7thApril2011London%20colour.pdf) Archived (https://web.archive.org/web/20 61. "Underground data center to help heat Helsinki | Green Tech – CNET News"
ca/news/localNews/2009/aug/geothermal100809.aspx). Northern Life, August
131203054940/http://www.ammonia21.com/web/assets/link/Hoffman7thApril2 (http://news.cnet.com/8301-11128_3-10405955-54.html). News.cnet.com.
12, 2009.
011London%20colour.pdf) 2013-12-03 at the Wayback Machine. Presented at 2009-11-29. Retrieved 2011-09-25.
Institute of Refrigeration, 7 April, London. 92. "Con Ed Steam" (https://web.archive.org/web/20070921191139/http://www.en
62. AGFW Branchenreport 2006 (http://www.agfw.de/typo3conf/ext/naw_securedl/
ergy.rochester.edu/us/coned.html). Energy.rochester.edu. Archived from the
33. http://setis.ec.europa.eu/system/files/JRCDistrictheatingandcooling.pdf secure.php?u=0&file=fileadmin/dokumente/wir/Branchenreport_2006/ab2006
original (http://www.energy.rochester.edu/us/coned.html) on 2007-09-21.
Combined Heat and Power and District Heating report. Joint Research gesamt_web.pdf&t=1187259422&hash=767cafb4adad1f785f119a86e2ea82c
Retrieved 2011-09-25.
Centre, Petten, under contract to European Commission, DG Energy 2013 4) Archived (https://web.archive.org/web/20070927222112/http://www.agfw.d
e/typo3conf/ext/naw_securedl/secure.php?u=0&file=fileadmin%2Fdokument 93. "A Brief History of Con Edison" (https://web.archive.org/web/2015111415201
34. DYRELUND Anders, Ramboll, 2010. Heat Plan Denmark 2010 (http://www.ra
e%2Fwir%2FBranchenreport_2006%2Fab2006gesamt_web.pdf&t=11872594 5/http://www.coned.com/history/steam.asp). Con Edison. Archived from the
mboll.com/~/media/Files/RGR/Documents/Documents/Heat-Plan-Denmark-20
22&hash=767cafb4adad1f785f119a86e2ea82c4) September 27, 2007, at the original (http://www.coned.com/history/steam.asp) on 2015-11-14. Retrieved
10-final.ashx). .
Wayback Machine, by the German Heat and Power Association -AGFW- (htt 2014-05-04.
35. Lund, Henrik; et al. (2017). "Smart energy and smart energy systems".
p://www.agfw.de) (in German). 94. "Explosion rocks central New York" (http://news.bbc.co.uk/1/hi/world/america
Energy. 137: 556–565. doi:10.1016/j.energy.2017.05.123 (https://doi.org/10.1
63. "Combined heat and power" (http://www.swm.de/english/company/energy-gen s/6905738.stm). BBC News. July 19, 2007. Retrieved May 1, 2010.
016%2Fj.energy.2017.05.123).
eration/combined-heat-power.html). www.swm.de. Retrieved 18 March 2018. 95. Barron, James (July 19, 2007). "Steam Blast Jolts Midtown, Killing One" (http
36. Pellegrini, Marco; Bianchini, Augusto (2018). "The Innovative Concept of Cold
64. Hungarian census 2011 (http://www.ksh.hu/nepszamlalas/tablak_lakas) table s://www.nytimes.com/2007/07/19/nyregion/19explode.html?ex=1342584000&
District Heating Networks: A Literature Review". Energies. 11: 236pp.
1.2.10 (Hungarian) en=c9164269910ddad6&ei=5124&partner=permalink&exprod=permalink).
doi:10.3390/en11010236 (https://doi.org/10.3390%2Fen11010236).
The New York Times. Retrieved May 1, 2010.
37. Buffa, Simone; et al. (2019). "5th generation district heating and cooling 65. "Cégünkről" (http://www.fotav.hu/fotav-zrt/cegunkrol/). FŐTÁV – Budapesti
Távhőszolgáltató Zrt. Retrieved 18 March 2018. 96. Jan Wagner; Stephen P. Kutska (October 2008). Monica Westerlund, ed.
systems: A review of existing cases in Europe". Renewable and Sustainable
"DENVER'S 128-YEAR-OLD STEAM SYSTEM: "THE BEST IS YET TO
Energy Reviews. 104: 504–522. doi:10.1016/j.rser.2018.12.059 (https://doi.or 66. "History of District Heating in Iceland" (https://web.archive.org/web/201110071
COME" " (http://www.districtenergy-digital.org/districtenergy/2008Q4?pg=18#p
g/10.1016%2Fj.rser.2018.12.059). 94242/http://www.mannvit.com/GeothermalEnergy/DistrictHeating/DistrictHeat
g18). District Energy. 94 (4): 16–20. ISSN 1077-6222 (https://www.worldcat.or
38. "Norwegian Water Resources and Energy Directorate" (https://web.archive.or inginIceland/). Mannvit.com. Archived from the original (http://www.mannvit.co
g/issn/1077-6222).
g/web/20110928144652/http://www.nve.no/global/energi/analyser/energi%20 m/GeothermalEnergy/DistrictHeating/DistrictHeatinginIceland/) on 2011-10-
07. Retrieved 2011-09-25. 97. "TemplatePowerplant" (https://web.archive.org/web/20100628105705/http://w
i%20norge%20folder/energy%20in%20norway%202009%20edition.pdf)
ww.xcelenergy.com/Colorado/Company/About_Energy_and_Rates/Power%2
(PDF). Archived from the original (http://www.nve.no/global/energi/analyser/en 67. Sean Duke (August 9, 2016). "An 'under the hood' look at Dublin's First
0Generation/ColoradoPlants/Pages/ZuniStation.aspx). Archived from the
ergi%20i%20norge%20folder/energy%20in%20norway%202009%20edition.p 'waste-to-energy' plant" (https://seanduke.com/2016/08/09/an-under-the-hood
original (http://www.xcelenergy.com/Colorado/Company/About_Energy_and_
df) (PDF) on 2011-09-28. Retrieved 2011-09-25. -look-at-dublins-first-waste-to-energy-plant/). Science Spinning.
Rates/Power%20Generation/ColoradoPlants/Pages/ZuniStation.aspx) on 28
39. Oliver, Christian (October 22, 2014). "EU warms to the potential efficiencies of 68. "Archived copy" (https://web.archive.org/web/20140506200928/http://www.ker June 2010. Retrieved 20 July 2010. "Plant Description: ... The facility also
district heating" (https://www.ft.com/content/02254fda-4966-11e4-8d68-00144f rycoco.ie/en/allservices/environment/energy/thefile,8007,en.pdf) (PDF). supplies steam for delivery to Xcel Energy's thermal energy customers in
eab7de). Financial Times. Retrieved 2018-09-07. Archived from the original (http://www.kerrycoco.ie/en/allservices/environmen downtown Denver. ... Plant History: Zuni Station was originally built in 1900
40. Kirill Eliseev (2011). District Heating Systems in Finland and Russia (https://w t/energy/thefile,8007,en.pdf) (PDF) on 2014-05-06. Retrieved 2014-05-06. and called the LaCombe Plant."
ww.theseus.fi/bitstream/handle/10024/25777/DISTRICT_HEATING_SYSTEM 69. http://www.glenstal.org/monastery/grounds/geothermal-glenstal/ 98. "District energy | combined heat and power plants | NRG Thermal
S_IN_FINLAND_AND_RUSSIA.pdf) (PDF) (Thesis). Mikkeli University of 70. Harmsen, J.; Powell, Joseph B. (2011-11-30). Sustainable Development in the Corporation" (http://www.nrgthermal.com). Nrgthermal.com. Retrieved
Applied Sciences. Process Industries: Cases and Impact (https://books.google.com/books?id=dL 2011-09-25.
41. Warsaw, Beth Gardiner in (2015-04-13). "How Warsaw's district heating oFc26geBUC&pg=PT102&dq=district+heating+rotterdam&hl=en&sa=X&ved= 99. [4] (http://www.fortchicago.com/our-businesses/power-business.html)
system keeps the capital cleaner than Kraków" (https://www.theguardian.com/ 0ahUKEwjboZWU347eAhUsUt8KHVrDAxYQ6AEIOzAD#v=onepage&q=distri Archived (https://web.archive.org/web/20100811064633/http://www.fortchicag
cities/2015/apr/13/warsaw-district-heating-system-poland-capital-cleaner-krak ct%20heating%20rotterdam&f=false). John Wiley & Sons. o.com/our-businesses/power-business.html) August 11, 2010, at the Wayback
ow). the Guardian. Retrieved 2018-10-07. ISBN 9781118209806. Machine
42. Dunne, Eimear. "Infographic explaining District Heating Systems" (https://web. 71. Hawkey, David; Webb, Janette; Lovell, Heather; McCrone, David; Tingey, 100. "Theodore Newton Vail and the Boston Heating Company, 1886–1890" (http
archive.org/web/20140505123952/http://frontlineenergy.ie/district-energy-infog Margaret; Winskel, Mark (2015-12-14). Sustainable Urban Energy Policy: s://web.archive.org/web/20090718051130/http://www.energy.rochester.edu/u
raphic/). Frontline Energy & Environmental. Archived from the original (http://fr Heat and the city (https://books.google.com/books?id=G700CwAAQBAJ&pg= s/ma/boston/bhc/). Energy.rochester.edu. Archived from the original (http://ww
ontlineenergy.ie/district-energy-infographic/) on 5 May 2014. Retrieved 5 May PT61&dq=district+heating+rotterdam&hl=en&sa=X&ved=0ahUKEwjboZWU34 w.energy.rochester.edu/us/ma/boston/bhc/) on 2009-07-18. Retrieved
2014. 7eAhUsUt8KHVrDAxYQ6AEIKTAA#v=onepage&q=district%20heating%20rott 2010-05-13.
43. Green heating system accused of causing 'fuel poverty' (https://www.bbc.co.u erdam&f=false). Routledge. ISBN 9781317577065.
101. "SACRAMENTO CENTRAL UTILITY PLANT – CASE STUDY" (http://alerton.
k/news/business-39736010) BBC 72. "Amsterdam stimuleert ontwikkeling duurzame warmtenetten" (https://www.du com/en-US/solutions/government/Case%20Studies/MK-CS-DGSCUP.pdf)
44. Dowling, Nicola; Goldberg, Adrian (30 April 2017). "Green scheme 'causing urzaambedrijfsleven.nl/energie/30093/warmtenetten-amsterdam) (in Dutch). 5 (PDF). Alerton.com. Retrieved 2013-10-25.
fuel poverty' " (https://www.bbc.co.uk/news/business-39736010). Retrieved Oct 2018.
102. "Energy Consumption - Sustainability at Rice University" (https://sustainability.
18 March 2018 – via www.bbc.co.uk. rice.edu/energy). sustainability.rice.edu. Retrieved 18 March 2018.

https://en.wikipedia.org/wiki/District_heating 7/8
3/20/2019 District heating - Wikipedia

103. "BYU Central Utilities Plant" (http://apmonitor.com/che436/index.php/Main/BY 110. "Heating & Cooling Plants – Physical Plant – UW–Madison" (https://physicalpl 117. "CNNC completes design of district heating reactor" (http://www.world-nuclear
UHeatingPlant). apmonitor.com. Retrieved 18 March 2018. ant.wisc.edu/heating-cooling-plants.htm). physicalplant.wisc.edu. Retrieved -news.org/Articles/CNNC-completes-design-of-district-heating-reactor). World
104. "Energy and Climate" (http://sustainability.georgetown.edu/initiatives/carbonfo 18 March 2018. Nuclear News. 7 September 2018. Retrieved 18 March 2019.
otprint). sustainability.georgetown.edu. Retrieved 18 March 2018. 111. "University of California cogeneration plant gets its power back" (http://www.c 118. Stanway, David (10 December 2017). "China looks to nuclear option to ease
105. "Combined Heat and Power Plant" (http://energyandsustainability.fs.cornell.ed ospp.com/articles/2013/10/university-of-california-cogeneration-plant-gets-its- winter heating woes" (https://uk.reuters.com/article/us-china-nuclear-heating/c
u/util/heating/production/cep.cfm). energyandsustainability.fs.cornell.edu. power-back.html). Retrieved 2015-12-20. hina-looks-to-nuclear-option-to-ease-winter-heating-woes-idUKKBN1E404J).
Retrieved 18 March 2018. 112. "MIT students seek to harness waste heat – MIT News Office" (http://web.mit. Reuters. Retrieved 18 March 2019.
106. "Custom content goes here" (http://energyandsustainability.fs.cornell.edu/util/c edu/newsoffice/2008/thermo-0724.html). Web.mit.edu. 2008-07-24. Retrieved 119. Sabine Froning (Euroheat & Power): DHC/CHP/RES a smile for the
ooling/production/lsc/). energyandsustainability.fs.cornell.edu. Retrieved 2011-09-25. environment, Kiev 2003 (http://www.euroheat.org/documents/030520.Kiev.pp
18 March 2018. 113. [5] (http://www.sustainableunh.unh.edu/climate_ed/cogen_landfillgas.html) t) Archived (https://web.archive.org/web/20090225073425/http://www.eurohea
Archived (https://web.archive.org/web/20100704080440/http://www.sustainabl t.org/documents/030520.Kiev.ppt) February 25, 2009, at the Wayback
107. "Archived copy" (https://web.archive.org/web/20131225073738/https://www.p
eunh.unh.edu/climate_ed/cogen_landfillgas.html) July 4, 2010, at the Machine
urdue.edu/ees/energy/wade/plantoperation.htm). Archived from the original (h
ttps://www.purdue.edu/ees/energy/wade/plantoperation.htm) on 2013-12-25. Wayback Machine 120. Puzakov, Viatchislav; Polivanov, Vasilii (2013). "Country by Country Survey—
Retrieved 2013-12-24. 114. "Heating Plant" (https://www.ndsu.edu/alphaindex/buildings/Building::371). Russia" (https://dbdh.dk/download/member_contries/russia_and_sng/RUSSI
www.ndsu.edu. Retrieved 18 March 2018. A%20country%20by%20country.pdf) (PDF). Danish Board of District Heating.
108. "Eastern Michigan University: Physical Plant" (http://www.emich.edu/physplan
Retrieved 2018-11-18.
t/shops/heat.php). www.emich.edu. Retrieved 18 March 2018. 115. "平成21年4月現在支部別熱供給事業者: The Japan Heat Service Utilities
109. "Archived copy" (https://web.archive.org/web/20150906063121/http://www.faci Associations 2009" (https://web.archive.org/web/20111007151412/http://www.j 121. "So heizt Deutschland heute" (https://www.bmwi-energiewende.de/EWD/Reda
dhc.or.jp/area/area01.html). Jdhc.or.jp. Archived from the original (http://www.j ktion/Newsletter/2015/15/Meldung/infografik-so-heizt-deutschland-
lities.udel.edu/centralplantoperations.aspx). Archived from the original (http://
dhc.or.jp/area/area01.html) on 2011-10-07. Retrieved 2011-09-25. heute.html). www.bmwi-energiewende.de. Retrieved 18 March 2018.
www.facilities.udel.edu/centralplantoperations.aspx) on 2015-09-06. Retrieved
2015-08-20. 116. "China signs agreement for nuclear heating demonstration project" (https://ww 122. "District Energy in France - Euroheat & Power" (https://www.euroheat.org/kno
w.neimagazine.com/news/newschina-signs-agreement-for-nuclear-heating-de wledge-centre/district-energy-france/). euroheat.org. 1 May 2017. Retrieved
monstration-project-7039593). Nuclear Engineering International. 14 March 18 March 2018.
2019. Retrieved 18 March 2019.

External links
UK's Information Portal on Decentralised and District Energy (https://web.archive.org/web/20080821183403/http://www.dekb.co.uk/)
District Energy Library (https://web.archive.org/web/20050405195629/http://www.energy.rochester.edu/)
Technical description of district heating and district cooling at Munich Airport, Germany (http://www.versorgungszentrale.de/?lang=e)
Geothermal District Heating, Iceland (https://web.archive.org/web/20090613014402/http://mannvit.com/GeothermalEnergy/DistrictHeating/DistrictHeatinginIceland)
Future Challenges for CHP in the UK and Continental Europe, Feb 2010 by F.Starr (http://www.claverton-energy.com/future-challenges-for-chp-in-the-uk-and-continental-europe-f-starr-phd-fimmm-c-eng-feb-2010.html)
Max Fordham argues against use of CHP District Heating (http://www.maxfordham.com/news/publications/a-case-against-the-widespread-use-of-district-heating-and-chp-in-the-uk)
Energy Hub – EU funded FP7 Project – District heating, cooling and power aiming for 100% on-site renewable energy at Leuven, Belgium (http://www.e-hub.org)
Advantages and Disadvantages of CHP district heating compared to heating and cooling from Heat Sharing Networks. (http://www.icax.co.uk/Advantages_District_Heating.html)
A Balanced Energy Network integrates heat pumps, demand side response and distributed heat storage in a district heat sharing network. (http://www.benuk.net)

Retrieved from "https://en.wikipedia.org/w/index.php?title=District_heating&oldid=888356502"

This page was last edited on 18 March 2019, at 16:31 (UTC).

Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a
non-profit organization.

https://en.wikipedia.org/wiki/District_heating 8/8