Anda di halaman 1dari 6

The Automation Component

AK 1703 ACP
Power made to measure

Power Transmission and Distribution


Automation,
communication and
telecontrol

High functionality and flexibili- One for all: AK 1703 ACP


ty are the basis for a successful The AK 1703 ACP opens up new possibilities for the automation
of power supply networks through innovative technologies such
automation system. And when as the ACP system concept. You can match the performance
you use the AK 1703 ACP, you and redundancy of the system perfectly to your requirements
can be sure it also includes through an extremely flexible combination of automation,
comprehensive telecontrol and telecontrol and communication functions.
communications functions and AK 1703 ACP offers you optimum support for this as
options for linking peripheral a central unit or telecontrol substation,
equipment. data node or front-end,
automation unit with independent
function groups and
with local or remote peripherals.

At the same time, AK 1703 ACP offers a wide range of different


interfaces for local and remote communications. Compatibility
with IEC standards 60870-5-101/103/104 is guaranteed by
consistent addressing from acquisition to output. However,
AK 1703 ACP can also be integrated seamlessly into existing
automation networks via many different third-party protocols,
thereby ensuring the long-term protection of your investments.

Intelligent peripherals
Apart from the central acquisition and output of process signals
in the AK 1703 ACP subrack the use of TM 1703 peripheral
elements allows a systematic reduction in the number of hard-
wired I/O interfaces through the direct connection of actuators
and sensors with wire cross sections of up to 2.5 mm2. Modules
for binary input and output up to 220 V DC also open up savings
potential at the interposing level. The TM 1703 peripheral
elements can also be placed as far away as 200 m from the
central unit for decentralized input/output.

Consistently simple engineering


The engineering process, from system diagnosis to online test,
can be implemented extremely cost-effectively via the object-
oriented SAT Toolbox II system, and also remotely. The close
interfacing with design tools such as ELCAD ensures the
consistent, uniform documentation of the whole system right
down to circuit diagram level. User programs for open-loop and
closed-loop control functions are created in CAEx plus in
accordance with IEC 61131-3, thereby minimizing training
costs.

Simple replacement: Plug & Play


A flash card is used in the AK 1703 ACP for storing parameters,
so that exchanging devices is a simple Plug & Play operation.
The configuration is transferred to the spare device with the
flash card. As a result, loading from a PC is not necessary and
the correct parameters are always available locally. This allows
comprehensive remote diagnosis options, and down times can
be reduced to a minimum.
AK 1703 ACP
In practical operation

Architecture Configurable telecontrol functions


Multi-processor and firmware principle with and without time tagging
with 32-bit processor technology Time synchronization via minute
One master control element with pulse, time signal receiver, serial
– up to 2 communication interfaces communications link or NTP server
– automation function (LAN/WAN)
– connection to the SAT Toolbox II Data routing via selective or automatic
engineering system data flow
Up to 16 additional processing and Uniform functionality as per IEC
communication elements 60870-5-101/103/104 for consistent
Up to 66 protocol elements for addressing from acquisition to output
– serial communication (point-to- Scalable redundancy through:
point, multi-point, dial-up traffic) – Duplication of 1 to 5 processing/
– LAN/WAN (Ethernet) communication elements
– Profibus DP – Duplication of the whole automation
Up to 272 peripheral elements unit
Independent functional groups
Overview of functions Decentralized archive
Node function for building up multi- Standby transmission route concept
hierarchical networks with virtually Parameter setting, diagnostics and
any topology testing by means of SAT Toolbox II
Automation functions at all levels of both locally and from remote locations
a local or distributed network Storage of parameters and firmware
Drawing up a function plan according on flash card
to IEC 61131-3 with CAEx plus for
open-loop and closed-loop control
functions

Configurations
Process control system SAT Toolbox II
AK 1703 ACP

Central unit:
NTP – Local input/output
– Central processing

AK 1703 ACP
– Data node
– Front end
– Gateway

AK 1703 ACP AK 1703 ACP AK 1703 ACP


– Turbine controller TC substation: Station control unit:
– Power plant management – Local processing – Process coupling
– Automation & control – Decentralized acquisition (serial, wide)
– Node function
– Automatic functions
Technical data

Type designation
Subrack CM-2832 AK 1703 ACP subrack for 9 slots
CM-2835 AK 1703 ACP subrack for 17 slots

Master control element CP-2010/CPC25 System functions, processing and communication

Processing and CP-2012/PCCE25 Processing and communication


communication element

Peripheral elements DI-2100/BISI25 Binary signal input (8 x 8, 24–60 VDC)


DI-2110/BISI26 Binary signal input (8 x 8, 24–60 VDC), 1 ms resolution
DI-2111/BISI26 Binary signal input (8 x 8, 110/220 VDC), 1 ms resolution
DO-2210/PCCO2x Secured command output 24–60 VDC
DO-2211/PCCO2x Secured command output 110–125 VDC
DO-2201/BISO25 Binary output (transistor, 40 x 1, 24–60 VDC)
AI-2300/PASI25 Analog input/output (16 x ±20 mA + 4 x 2 opt. exp.)
MX-2400/USIO2x Signal input/output (24–60 VDC, ±20 mA, opt. exp.)

Power supply PS-5620 Power supply module, 24–60 VDC


PS-5622 Power supply module, 110–220 VDC, 115–230 VAC

Open-loop and closed- 256 kB for user program


loop control function approx. 50,000 variables and signals, 2,000 of which buffered
(per master control/ 250 buffered nominal values
processing element)

Third-party protocols Modbus, DNP 3.0, IEC 61107, various ABB, Siemens, L&G, AEG, ...

EMC IEC 60870-2, IEC 60255, IEC 60654, IEC 60950, IEC 61000, EN50082, CISPR 22, ...

Temperature range 0 ... +55 °C

Relative humidity 5 to 95 % non-condensing (IEC 60654-1 C2, IEC 60870-2-2 C2)

Vibration and shock resistance IEC 60870-2-2 Cl. Bm, IEC 60255-21-1 Cl.2, IEC 60255-21-2 Cl.2

Dimensions CM-2832: 280 x 291 x 285 mm (W x H x D); space requirement: 400 x 451 x 290 mm (W x H x D)
CM-2835: 483 x 291 x 285 mm (W x H x D); space requirement: 604 x 451 x 290 mm (W x H x D)
AK 1703 ACP –
The advantages at a glance
Applications Simple engineering and maintenance
As telecontrol substation or central Creation of user programs for open-
unit loop and closed-loop control functions
With local or remote peripherals as per IEC 61131-3
As data node, front-end or gateway Object-oriented engineering
Automation unit with independent Consistent data storage
functional groups Engineering also possible from remote
For rear panel or 19” rack installation locations
Plug & Play for spare parts by means of
Comprehensive communication flash card
Up to 66 serial interfaces for local Storage of parameters and firmware
and remote communication on flash card
Communication (serial, LAN/WAN) Exchanging of modules without
as per IEC 60870-5-101/103/104 engineering tool
and IEC 61850
Numerous third-party protocols TM 1703: The intelligent terminal
available Direct connection of actuators and
Profibus DP sensors with wire cross-sections of up
to 2.5 mm2
Scalable redundancy Remote installation possible
Component redundancy up to 200 m away
Duplication of processing/ Binary input/output also for
communication elements 110/220 VDC
Mounting on 35 mm DIN rail
Siemens AG
Power Transmission
and Distribution
Energy Automation Division
P.O. Box 4806
90026 Nuremberg
Germany

www.siemens.com/energy

The information in this document contains general


descriptions of the technical options available, which
do not always have to be present in individual cases.
The required features should therefore be specified
in each individual case at the time of closing the
contract.

Subject to change without prior notice.

Order No. E50001-U321-A251-X-7600


Printed in Germany
Dispo 06200
TH 345-060137 101789 PA 04062.0

If you have any question about


Power Transmission and Distribution,
our Customer Support Center
is available around the clock.

Tel.: +49 180/524 70 00


Fax: +49 180/524 24 71
(Subject to charges, e.g.: 12 ct/min.)

E-mail: support.energy@siemens.com
www.siemens.com/energy-support

Anda mungkin juga menyukai