D = 500.00 mm
Where :
Object Ug = geometric unsharpness
F = source size : the maximum projected dimension of the
radiating source (or effective focal spot) in the plane
Film d = 6.00 mm perpendicular to the distance D from the weld or
object being radiographed.
Ug = 0.05 mm D = distance from source of radiation to weld or
object being radiographed.
Ug = Fd/D d = distance from source side of weld
or object being radiographed to the film.