Pressure Transmitters
Our level instruments offering continues to grow to meet your application needs. Lesman can provide you with everything
from the simplest float-type mechanical switch to radar level transmitters that work in obstructed tanks. Not sure which
will fit your process best? We can help. Just fill out an level application datasheet and fax it to us for engineering review.
Due to manufacturer agreements, not all products are available in all geographic areas and markets.
Anderson Greenwood
Prices See publication date, and are subject to change
Instrument Valves
Start at Page without notice.
Switches
Mechanical Bottle and Float-Type Level Switches $34.00 198
Kobold Economical Level Switches $506.00 199
Level Measurement
Siemens CLS100 Two-Wire Capacitance Point Level Switch $174.00 203
Instruments
Siemens CLS200 Capacitance Point Level Detection Switches $396.00 204
Siemens CLS300 Capacitance Point Level Switch for Harsh Environments $544.00 206
Siemens CLS500 Capacitance Point Level Switch for Extreme Conditions $599.00 208
Siemens LPS200 Rotating Paddle Switch for Bulk Solids $275.00 200
Siemens LVS200 Vibrating Fork Switch for Bulk Solids $463.00 201
Siemens ULS200 Ultrasonic Point Level Detection Switch $775.00 202
Transmitters
Flow Measurement
GE Sensors Submersible Level Sensors for OEM Applications Call 215
Honeywell ST3000 Flange Mount Smart Transmitter for Liquid Level $1513.00 217
Instruments
Sartorius (GWT) PanCake® Load Cells for Level by Weight Call 210
Siemens Hydroranger 200 Wastewater Monitoring and Control System $1325.00 228
Siemens MultiRanger 100/200 Ultrasonic Continuous Level Transceivers $926.00 226
Siemens Probe Ultrasonic Continuous Level Transmitter for Liquid Level $840.00 223
Siemens SITRANS LC300 Capacitance Continuous Level Transmitters $494.00 218
Siemens SITRANS LC500 Capacitance Continuous Level Transmitters $535.00 220
Siemens SITRANS LG200 Guided Wave Radar System Call 248
Siemens Water Technologies Loop Powered Submersible Level Transmitter $1000.00 215
Pneumatic Drives
WIKA LH-10 and LS-10 Submersible Transmitter for Liquid Level $392.10 214
Accessories
Sartorius ProBatch+ Batch Processing and Recipe Management Software $3655.00 212
Siemens Echomax Ultrasonic Level Transducers and Accessories $440.00 234
Siemens SIMATIC PDM Configuration Software Utility $575.00 188
Some products are not available in all
Siemens SmartLinx™ Communications Interface Modules $716.00 229 Lesman markets or geographic areas.
FLOAT Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
198 SWITCHES Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
amid; Cable: 5 ft. PVC; O-ring: Brass units: Buna-N, SS units: Viton
Liquid Level
Instruments
Reed Switch: SPST, N/O (factory-set), or N/C; Max. contact rating: 60 VA, 60
• For all liquid types watt; 250 VAC @ 2A
• SPDT mercury switch Model Selection Guide
• Polyethylene, Teflon, or Float Size Specific Min. Fluid Housing Material
316 Ti stainless steel float L x Diam. Gravity Density Brass Stainless Steel
• Temperatures to 320°F, 1” x 0.87” 0.75 min. 0.72 g/ml NV-5101 $168.00 NV-5201 $230.00
Pressures to 30 PSIG 2” x 0.87” 0.66 min. 0.63 g/ml NV-5103 168.00 NV-5203 237.00
Need a float switch in
polypropylene? Call us.
Flow Measurement
Chemical-Resistant
Instruments
Guide
Pneumatic Drives
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
SWITCHES 199
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
• No moving parts
Instrument Valves
• Temperatures to 480°F, Pressures to 360 PSIG • Good to 270°F Ultrasonic
level switch
• High capacity 10 Amp switch Kobold’s NQ is a com-
• All 316 stainless steel wetted parts pact ultrasonic level
switch that activates when immersed in liquid. Its short 1.42” intrusion
• All-metal design ideal for harsh environments length makes it the ideal choice for applications in small containers.
Specifications Specifications
Operating Conditions: Media temperature:480°F; Pressure: 360 PSIG max Power Requirements: Two-wire installation: 24-240 VAC/VDC, 50/60 Hz;
Process Medium: Specific gravity 0.7 minimum Three-wire installation: 24 VDC, 50/60 Hz
Construction: NEMA 4/IP65 epoxy-coated aluminum housing, 316SS wetted Electrical Characteristics: Two-wire installation: 24-240 VDC/VAC supply/
materials with square flange or 2” NPT fitting; optional 1/2” NPT conduit switch,500 mA max ON current,2–7.5 mA OFF current; Three-wire installation:
Level Measurement
Switch: SPDT microswitch, 10 Amp @ 250 VAC, 0.6 Amp @ 220 VDC, 3/4” 24 VDC supply, 18 VDC signal, Voltage drop: 4.5V @ 500 mA, 10V @7.5 mA
Instruments
switch hysteresis Leakage Current: 2 mA (switch off )
Switching Delays: Wet to dry: 500 ms; Dry to wet: 50 ms
Model Selection Guide
Operating Conditions: Media temperature: -40° to 270°F; Ambient tempera-
Catalog ture: 160°F max with 210°F fluid or 120°F max with 270°F fluid; Operating
Fitting Style Number Price pressure: 1000 PSIG max @
NGS float switch with square flange fitting NGS-2100 $506.00 40° to 120°F, 760 PSIG max Model Selection Guide
NGS float switch with 2” NPT fitting NGS-2200 639.00 @ -40° to 270°F Catalog
1/2” NPT electrical conduit connection -C 18.00 Construction: Glass fiber-re- Shielded Switch Number Price
Options NGS-2100 Carbon steel mating flange NGS-MFF1 119.00 inforced Nylon and 316SS Level Switch NQ-2000 $710.00
NGS-2100 316 stainless steel mating flange NGS-MFF2 246.00 housing, stainless steel 1/2” NPT Conduit Fitting -C 15.00
Flow Measurement
sensor; NEMA 4X rating Connector Cable -M12 80.00
Instruments
Vibrating Level Switch
• No-wear components
• Unaffected by external vibration
Microwave Food-safe
radar level
• User-selectable switch logic Vibrating Level Switch switch
• High capacity 10 Amp switch fork • Good to 212°F (to 302°F
for 30 minutes for CIP
• LED displays switch status, power applications)
Switch: SPDT microswitch, 10 Amp @ 250 VAC, 0.6 Amp @ 220 VDC, 3/4”
Construction: Stainless steel head and thread supports,PEEK coupler,hygienic
Pneumatic Drives
switch hysteresis
weld-in sleeves, IP67 protection rating
Model Selection Guide Connections: Process: G1/2, M12x1.5; Cable: M16x15 threaded connection
Catalog Output: Open collector, PNP, 50 mA
Description Number Price Switch Delay: 0.2 seconds standard, 0.3–1.0s available on request
2” insertion depth switch, 3/4” NPT fitting NWS-5220 $518.00 Power Supply: 18-36 VDC, <50 mA without load
2” insertion depth, 1” NPT fitting NWS-5225 518.00 Dielectric Constant: >20
2” insertion depth, 2” Tri-Clamp fitting NWS-7250 714.00
4” insertion depth, 1” NPT NWS-6225 535.00 Call Lesman for pricing and delivery.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
200 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Siemens SITRANS LPS200 rotary paddle switch detects full, empty, or Ordering Instructions
demand conditions on materials like grain, feed, cement, plastic granu-
Make one selection from each table section below. Check the availability
late, and wood chips. The LPS paddle switch can handle bulk densities column to be sure the unit you need is available. A finished catalog number
as low as 100 g/l with the standard measuring vane , or 35g/l with the looks like this: 7ML5725-5EE11-2AC0
hinged vane.
Please submit orders to: Siemens Industry Inc,
A low revolution geared motor with slip clutch drives a rotating vane Model Selection Guide c/o Lesman Instrument Company.
that senses the presence of material at the LPS mounted level. As mate- Description Model Price
rial comes into contact with the rotating paddle, rotation stops, which
changes the microswitch state. When the paddle is no longer covered, LPS200 compact version with 1.25” NPT threaded connection, Process pressure
to 7.25 psi (0.5 bar), measuring vane 1.38” x 4.17”
Flow Measurement
Down to 15 g/l; (depends on shaft/vane coverage) Agency CSA/FM Dust Ignition Proof _ _ A0 84.00
Power: Jumper selectable; 115 VAC, ±15%, 50-60 Hz, 4 VA, 230 VAC, ±15%, 50 Approvals CSA/FM General Purpose _ _ C0 0.00
Hz, 6 VA, or 24 VDC, ±15%, 2.5 W
Alarm Output: Relay 5A at 250 VAC, noninductive Quick Ship Models (Two week standard delivery)
Material: Enclosure: Epoxy coated aluminum, Type 4/NEMA 4/IP65; Process Compact LPS200, aluminum, 115 VAC power, 1 rev/min, 1.25” NPT thread, 7.25
connection: 1-1/4” NPT, stainless steel; Conduit entry: 2 x 1/2” NPT; Measuring PSI max pressure, 3.94” extension, 1.38”x 4.17” boot shaped vane, CSA/FM
shaft and vane: Stainless steel General Purpose approval
Approvals: FM/CSA Class II, Div. 2, Groups E–G; LPS200 compact aluminum model 7ML5725-5EE11-2AC0 $205.00
ATEX II 1/2 D (dust explosion); CE Compact LPS200, stainless steel, switch-selectable power, 1 rev/min, 1.25” NPT
thread, 7.25 PSI max pressure, 5.91” extension, 1.38”x 4.17” boot shaped vane,
Accessories CSA/FM Dust Ignition Proof approval
LPS200 compact stainless steel model 7ML5725-6QE12-2AA0 293.00
Actuator Motors and
Catalog
Pneumatic Drives
Description Number Price Extended design LPS200, 303 stainless steel, switch-selectable power, 1 rev/
SITRANS LPS200 Instruction Manual 7ML1998-5FS62 $11.00 min, 1.25” NPT thread, 7.25 PSI max pressure, 7.87” extension, 1.38”x 4.17” boot
Motor Gear/PLC-Multivoltage 7ML1830-1KG 174.00 shaped vane, CSA/FM Dust Ignition Proof approval
Replacement Vane, Boot Shape, 35 x 106 mm 7ML1830-1KH 23.00 LPS200 extended stainless steel model 7ML5726-5QC12-2BA1 352.00
Hinged Vane, 65 x 210 mm 7ML1830-1KJ 50.00
Rigid Extension Kit: Spring coupling, rigid tube extension, and required pins.
Extended design models and cable extension
500, 400, and 300mm 7ML5711-0AA 31.00 models also available. Call for current pricing
Length 1000, 900, 800, 700, and 600 mm
1500, 1400, 1300, 1200, and 1100mm
7ML5711-1AA
7ML5711-2AA
41.00
58.00 and model selection options.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790 POINT LEVEL 201
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
• Extension lengths to 4000mm (157”) failsafe high/low selection
Instrument Valves
Vibrating Fork Technology
As soon as you apply power, the LVS200 forks by material contact, and the resulting signal falls
vibrate. The forks are very active and sensitive at below the sensitivity threshold.
the tip — not at the base — to help resist detect- The forks vibrate at a high amplitude, but with
ing material buildup between the forks. low energy.This ensures reliable detection of even
A dual crystal pack is directly coupled to the the lightest material, and avoids the tendency to
vibrating legs to generate high amplitude, low burrow and lose contact.
LVS200 with pipe extensions frequency (125 Hz) vibration, providing optimum Factory sensitivity setting fits most applications,
start at $645.00 self-cleaning characteristics during operation. especially for light materials. For higher density
Level Measurement
Cable extension LVS200 A third passive crystal senses the fork vibration. materials, operating sensitivity can be switched
models start at $603.00 Relays activate when fork vibration is damped lower to avoid some material adhesion.
Instruments
The SITRANS LVS200 is an electromechanical vibratory switch for level Ordering Instructions
detection of powder and granular solids. Make one selection from each table section below. Check the availability
The SITRANS LVS200 is an excellent solution for low bulk density, low column to be sure the unit you need is available. A finished catalog number
humidity/adhesion, and free flowing applications. This unit is ideal for looks like this: 7ML5731-7AB11-1AA0
new installations or for replacing:
Please submit orders to: Siemens Industry Inc,
• Diaphragm-based switches subject to rupture Model Selection Guide c/o Lesman Instrument Company.
• Problematic rotating paddle switches Basic LVS200, 19-230 VAC/19-55 VDC, one SPDT relay output, no temperature
isolator, 1.5” NPT threaded process connection, 304SS standard extension, with
Flow Measurement
• Electrostatic discharge sensitive switches CSA/FM dust-ignition proof approval 7ML5731-7AB11-1AA0 $431.00
• Material dielectric sensitive switches
Instruments
Description Model Price
• Switches that require special application configuration or multiple LVS200 standard vibrating point level switch for high or low levels of bulk solids.
The standard LVS200 detects high or low levels of dry bulk solids in 19–230 VAC, 19–55 VDC, One Relay Output (SPDT) 7ML5731-1 $422.00
bins, silos, or hoppers. The liquid/solid interface version can also detect 19–230 VAC, 19–55 VDC, Two Relay Outputs (DPDT) 7ML5731-2 463.00
settled solids within liquids or solids in confined spaces, like feed pipes. Process No Temperature Isolator _ A _ _ _ - 0.00
It is designed to ignore liquids in order to detect the interface between Temperature Temperature Isolator _ B _ _ _ - 112.00
a solid and a liquid. A pipe extension version is available with either the Process 1.5” NPT Threaded (ANSI/ASME B1.20.1) _ _ B _ _- 0.00
standard or liquid/solid interface electronics and fork, separated by a Connection 2” NPT Threaded, Sliding Sleeve _ _ D _ _- 168.00
customer-supplied 1” pipe. 2” ASME Flange 150 Lb _ _ G _ _- 200.00
3” ASME Flange 150 Lb _ _ H _ _- 261.00
Power: 19-230 VAC, ±10%, 50-60 Hz, 8 VA or 19-55 VDC, ±10%, 1.5 W Remote enclosure and cable, longer extensions (to
Alarm Output: Relay delay: Approx. 1 second from loss of vibration; Approx.
4000mm) available. Call for pricing.
1 to 2 seconds from resumption of vibration; Relay failsafe: High or low,
switch selectable; Relay 8A at 250 VAC, noninductive Accessories
Material: Enclosure: Epoxy coated aluminum, NEMA 4/Type 4/IP65; Process Catalog
Description Number Price
connection: 1.5” NPT; Sensor: Stainless steel; Conduit entry: 1/2” NPT
SITRANS LVS200 User Manual 7ML1998-5FT62 $11.00
Approvals: FM/CSA Class II, Div. 1, Groups E–G, Class Replacement Electronics Module (125Hz) 7ML1830-1KL 205.00
III; ATEX II 1/2 D (Dust Explosion Proof ); CE 2” NPT Sliding Sleeve 7ML1830-1JN 199.00
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
202 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
on bulk solids (0.8 to 9.8 ft.), liquids and continuous level devices.
Instrument Valves
Intelligence® software
24 VDC, Relay Output 1 _ _ _ _ 0.00
Instruments
or 2 form C (SPDT) contacts, rated 5A Parts and Universal Adaptor, 2” NPT 7ML1830-1BT 111.00
at 48 VDC Accessories Polycarbonate Lid 7ML1830-1LG 12.00
Aluminum Lid 7ML1830-1LH 29.00
LCD Display: Displays three 0.35” digits for programming distance between English Quick Start Manual 7ML1998-1XB81 22.00
sensor face and material. Multi-segment graphic for operation status.
Note 1: For hazardous applications, available only with aluminum
Programming: 2 keys housing option 04.
Power Supply: 18 to 30 VDC, 3W max. or 100 to 230 VAC max.
Terminal Block Wiring: 14 gauge solid/16 gauge stranded max.
Note: The ultrasonic Pointek ULS200 is intended
Cable Entry (2 connections): Polycarbonate enclosure: PG 13.5 or 1/2” NPT.
Aluminum enclosure: 1/2” NPT or PG 13.5 to be a primary measurement and control device.
Sensor Mounting: Threaded: 2” NPT, 2” BSP or PF2. For overfill or level safe protection, Siemens ad-
Electronics Enclosure: Material: Polycarbonate or Epoxy coated vises using Pointek contacting technology, like the
CLS200 on pages 204 to 205 of this catalog.
Actuator Motors and
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
POINT LEVEL 203
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
• Level detection independent of tank wall or pipe system
Instrument Valves
• Simple setup procedure, verification with built-in LEDs
• Precision 20-turn potentiometer for adjustable sensitivity
• Two level outputs: Two-wire current loop detection and solid-state transistor relay
• Low maintenance costs. No moving parts
• Can be connected directly to most PLCs
• Intrinsically safe and dust/ignition-proof models CLS100
Level Measurement
Instruments
Specifications
Models: Standard, intrinsically safe
CLS100 Through the “Looking Glass”
Modes of Operation: High/low CLS100 has been field-tested in many appli-
Switchpoint Repeatability: 0.08” cations. It’s sensitive enough to measure levels
Operating Frequency: 5.5 MHz accurately through tank windows and site
Dielectric Constant: 1.5 min. glasses made of plastic, glass, or fiberglass.
Temperature Range: -40° to 257° F It works with a heavy material buildup on
Pressure (Vessel) Range: 0 absolute to the sensor (like chocolate or dust), and even in
Flow Measurement
2500 kPa (25 bar or 365 PSI) gauge sludge interfaces. Want a demo? Call us!
Adjustment Potentiometer: 20-turn
Instruments
Current Output: 0/4-20 mA loop sup-
plied; Current Reversible: By polarity
change power supply; Load: 600Ω max. Ordering Instructions
@ 24 VDC Select one option from each table section below. A completed catalog
Solid-State Switch: Output: Galvanically number looks like this: 7ML5501 - _ _ _ _ _
isolated, 100 mA max. load current;
Switch voltage: 28 VAC/40 VDC max. Please submit orders to: Siemens Industry Inc,
Model Selection Guide c/o Lesman Instrument Company.
Integrated Enclosure: Housing (Electron
Catalog Price
ics)/Connection: AISI 316L stainless steel;
SensGuard Chemical-Resistant Probe Cover CLS Flange, 3/4” Thread for Mounting
Pressure Range: Full vacuum to 25 bar (FV to 365 PSI) any 3/4” NPT Pointek CLS Level Switch 7ML1500-0_ _0 0.00
Temperature Range: -40º to 125º C (-40º to 257º F) Pressure Rating (ANSI B16.5)
150 Lbs. (_ A) 300 Lbs. (_ B) 600 Lbs. (_ C)
Construction: Polyphenylene Sulfide, fiberglass filled
Flanged 1” (A _) $162.00 $197.00 $207.00
Process Connections: External: 3/4” NPT; Internal: 3/4” NPT Process 1.5” (B _) 195.00 228.00 249.00
Insert Length: 2.75” Connection 2” (C _) 232.00 260.00 301.00
Size 3” (D _) 277.00 338.00 365.00
Flexural Strength: 315 lbs. 4” (E _) 333.00 428.00 508.00
CAPACITANCE Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
204 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Standard Models: Suitable for use in virtually any point level detection
application.With a minimum insertion length of just 4 inches compared
with 14 inches on competitive products, the standard model can be
easily installed in small diameter pipes. In tank applications, content
capacity can be maximized.
Sanitary Models: Meet industry requirements for temperatures exceed-
ing 212° F. The process connection is a sanitary standard tri-clamp.
Wetted parts of 316L stainless steel and PVDF (Kynar®) are 3A compli-
ant and food-grade safe.
Extended Models: Available in both cable and rigid versions. When it is
Pointek CLS capacitance point level detection devices: not possible to penetrate the tank wall near the bottom, Pointek CLS
Level Measurement
• Compact design and 3.9” insertion length, so you can use temperature of the transmitter can exceed 185° F due to hot processes.
more of your tank for product. The isolator extension raises the enclosure approximately 4” above
Instruments
• Adjustable insertion lengths: Slide coupling lets you put the process fitting.
more probe into the process. Process Connections: Process connection sizes range from 3/4” to 1.5
NPT and 1” to 3” sanitary flange.
• Mounting options: 3/4”, 1”, 1.5” NPT, 3A sanitary, and flanges.
Adjustable Sliding Process Mount: For applications where the exact
• Electronics tested to 4G vibration levels in three dimensions. level sensing point is in doubt, a sliding process sealing gland is avail-
• Flame-, explosion-, and dust/ignition-proof approvals. able to provide exact adjustment of the sensor’s position.
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
POINT LEVEL 205
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
delay test/adjust, high low sensitivity Description Number Each
Instrument Valves
Temperature Range: -40° to 185°F operation and storage CLS200 Capacitance Point Level Detection Sensor 7ML5630 - $396.00
Materials: Process Connection: 316L Stainless Steel; Probe: PPS (Ryton); Threaded, 3/4” NPT 0A_ _ _- 0.00
Enclosure: Epoxy Coated Aluminum (NEMA 4X, 7/9, IP65) 316L SS Threaded, 1” NPT 0B_ _ _- 24.00
Process Threaded, 1.25” NPT 0C_ _ _- 33.00
Switch Point Repeatability: 0.08”; Hysteresis: 0.08” Connection Threaded, 1.5” NPT 0D_ _ _- 56.00
Dielectric Constant: 1.5 minimum 1” ASME, 150 Lb Welded Flange 5A_ _ _- 188.00
1.5” ASME, 150 Lb Welded Flange 5D_ _ _- 227.00
Operating Frequency: 5 MHz maximum
2” ASME, 150 Lb Welded Flange 5G_ _ _- 271.00
Cable Entry: 1/2” NPT; Cable Gland: PG 13.5 (available) 3” ASME, 150 Lb Welded Flange 5K_ _ _- 323.00
4” ASME, 150 Lb Welded Flange 5N_ _ _- 388.00
Output Functions
Standard Insertion Lengths (No Y01 code needed.) Length from flange face.
Relay Contact: Form C SPDT, NC or NO contact selectable Threaded lengths include process connection
Level Measurement
Contact Load: 10 mA/50 VDC min., 50A/30 VDC max.; 8A/250 VAC max. Standard Compact (Threaded 120mm, Flanged 98mm) _ _ A _ _- 0.00
Switching Capacity: 2000VA/150 Watt max. Standard Extended Rod 250 mm 9.84” _ _ B _ _- 57.00
Instruments
Standard Extended Rod 350 mm 13.78” _ _ C _ _- 114.00
Solid-State Switch: Galvanically isolated, with sensor failure detection Standard Extended Rod 500 mm 19.69” _ _ D _ _- 133.00
Safety: Non-polarity sensitive (no wiring errors) Standard Extended Rod 750 mm 29.53” _ _ E _ _- 171.00
Switch Voltage: 250 VAC/300 VDC max.; Voltage Drop: <1 Volt Standard Extended Rod 1000 mm 39.37” _ _ F _ _- 181.00
Standard Extended Rod 1250 mm 49.21” _ _ G _ _- 190.00
Load: 2 Watt max. Load Current: 100 mA max. Standard Extended Rod 1350 mm 53.15” _ _ H _ _- 200.00
Time Delay: (On/Off ) 1-60 seconds Standard Extended Rod 1500 mm 59.06” _ _ J _ _- 209.00
Standard Extended Rod 1750 mm 68.09” _ _ K _ _- 219.00
Approvals: General Purpose; Dust/Ignition-Proof:
Standard Extended Rod 2000 mm 78.74” _ _ L _ _- 228.00
CSA/FM Class II, Div. 1, Group E, F, G, Class III; Flame-
Proof; FM Class I, Div. 1, Groups A-D; Explosion-Proof: No Thermal Isolator _ _ _ 0 _- 0.00
CSA Class I, Div. 1, Groups A-D Temp/ Thermal Isolator (Process Temps >185°F) _ _ _ 1 _- 38.00
Flow Measurement
Electronics Remote Mount Electronics, 2m Cable _ _ _ 2 _- 220.00
Standard Model Extended Rigid Model Remote Mount Electronics, 5m Cable _ _ _ 3 _- 233.00
Instruments
Process Connections: 3/4” NPT Process Connections: 3/4” NPT Wetted FKM _ _ _ _ 0- 0.00
Materials FFKM (Process Temps > -47°F) _ _ _ _ 1- 95.00
Maximum Length: 4” Maximum Length: 216”
Probe 316L SS with PPS Probe Body 0 _ _ _ 0.00
Resistance: 365 PSI maximum Resistance: 365 PSI maximum Material 316L SS with PVDF Probe Body 1 _ _ _ 38.00
Sanitary Model Extended Cable Model CSA/FM/CE General Service _ A _ _ 0.00
Approvals CSA/FM Dust-Ignition Proof, IS Probe _ F _ _ 38.00
Process Connections: 1”, 1.5” or 2” Process Connections: 3/4” NPT CSA/FM Explosion Proof, IS Probe _ G _ _ 90.00
Tri-Clamp Maximum Length: 1,378” Enclosure IP65 Rating _ _ A0 0.00
Maximum Length: 4” Tensile Strength: 396 Lbs. max IP68 Rating _ _ C0 34.00
V 03.2010
206 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
in the transmitter.
When the capacitance increases or decreases with the level of
material, the measuring frequency changes inversely.The same signal
is also connected to the active shield portion of the probe, effectively
eliminating the electrical potential difference between the shield and
the measurement section. The probe will not be affected by changes
in vapor concentration, dust, or condensation.
The CLS300 will provide accurate level detection even in highly
conductive materials with build-up on the probe.
Thermal
Level Measurement
CLS300 isolator
eliminates Fully potted
Instruments
effect of transmitter
Features process unaffected by
temperature condensation,
• One design fits all, even in harsh and heavy duty environ dust, or
ments; suitable for high pressures and high temperatures in vibration
liquids, solids, slurries, and interfaces
• All wetted parts made of stainless steel and PFA, Teflon, or
ceramics for high-chemical resistance
• High-sensitivity probe provides accurate level detection
without the effects of conductive material buildup. Works Explosion and flame-proof
Flow Measurement
ceramics can be supplied. Materials with low or high dielectric properties High-
are accurately detected, and the unique active shield helps in ignoring Standard Temperature
the effects of buildup. Model Model
Its unique modular design provides for a wide range of configurations,
process connections, extensions, and approvals to meet the precise
temperature and pressure requirements of specific applications. The Cap Cable
modular design makes it easy to specify and reduces stocking require- (All Models) Model
ments. A wide range of probe configurations is available, including rod
and cable/rope models.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CAPACITANCE
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
POINT LEVEL 207
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Probe Lengths: Rod version: 14” to 40”; Rope/cable version: 20” to 985” Description Number Each
Instrument Valves
CLS300 Capacitance Point Level Detection Sensor 7ML5650 - $544.00
Wetted Parts: AISI 316L/PFA/Peek; High-temperature version: AISI 316L/
ceramics AI203 (99.7%) Threaded, 3/4” NPT 0A_ _ _- 0.00
316L SS Threaded, 1” NPT 0B_ _ _- 24.00
Tensile Force: 4,188 lbs. max. Process Threaded, 1.25” NPT 0C_ _ _- 33.00
Temperature Range: -40° to 398°F; High-temperature version: -40° to 752°F Connection Threaded, 1.5” NPT 0D_ _ _- 56.00
Pressure Range: 511 PSIG 1” ASME, 150 Lb Welded Flange 5A_ _ _- 188.00
Dielectric constants table 1” ASME, 300 Lb Welded Flange 5B_ _ _- 229.00
Dielectric Constant: 1.5 min. available on page 484. 1.5” ASME, 150 Lb Welded Flange 5D_ _ _- 227.00
Enclosure: Epoxy coated, NEMA 4/Type 4/IP65 1.5” ASME, 300 Lb Welded Flange 5E_ _ _- 266.00
2” ASME, 150 Lb Welded Flange 5G_ _ _- 271.00
Process Connection: NPT/BSPT/JIS 2” ASME, 300 Lb Welded Flange 5H_ _ _- 303.00
Power Supply and Transmitter 3” ASME, 150 Lb Welded Flange 5K_ _ _- 323.00
3” ASME, 300 Lb Welded Flange 5L_ _ _- 394.00
Level Measurement
Supply Voltage: 12-250 VAC/VDC any polarity galvanically isolated 4” ASME, 150 Lb Welded Flange 5N_ _ _- 388.00
Instruments
Power Consumption: 2 VA/2 Watt 4” ASME, 300 Lb Welded Flange 5P_ _ _- 499.00
Wiring Connections: Max. 0.009”; Temperature range: -40° to 185°F Standard Probe Lengths (No Y01 code needed.) Length from flange face.
Threaded lengths include process connection
Signal Indicators: 3 LEDs for adjustment control, output status and power
Standard Extended Rod 350 mm 13.78” _ _ A _ _- 0.00
Adjustment Potentiometers: 2 PCS, for time delay and sensitivity Standard Extended Rod 500 mm 19.69” _ _ B _ _- 33.00
Adjustment Switches: 5 PST dip switch for time delay select.Failsafe high/low Standard Extended Rod 750 mm 29.53” _ _ C _ _- 63.00
and time delay test/adjust, high/low sensitivity Standard Extended Rod 1000 mm 39.37” _ _ D _ _- 81.00
Sensitivity: 1% max. change in actual capacitance Temp. No Thermal Isolator _ _ _ 0 _- 0.00
Options Thermal Isolator (Process Temps >185°F) _ _ _ 1 _- 53.00
Temperature Drift: 0.2% max. of actual capacitance value
Wetted FKM _ _ _ _ 0- 0.00
Measurement Frequency: 600 kHz max. Seals FFKM (Process Temps > -47°F) _ _ _ _ 1- 300.00
Flow Measurement
E.S.D. Protection (kV): Protected to 55 kV continuous discharge Probe 316L SS, PFA Lining, PEEK Isolators 0 _ _ _ 0.00
Instruments
Output Functions CSA/FM/CE General Service _ A _ _ 0.00
Approvals CSA/FM Dust-Ignition Proof, IS Probe _ F _ _ 30.00
Relay Contact (with Signal Failure Detection): Contact: Form C SPDT (se- CSA/FM Explosion Proof, IS Probe _ G _ _ 40.00
lectable NC or NO contact); Max. contact load: DC: 5A/30 VDC; AC: 8A/250
VAC (cosn=1); Max. switching capacity: 150 Watt/2000 VA; Min. contact load: Enclosure IP65 Rating _ _ A _ 0.00
10 mA/5 VDC; Time delay (on and/or off ): 1-60 seconds IP68 Rating _ _ C _ 34.00
Solid-State Switch (with Signal Failure Detection): Output: Galvanically Active 125mm Threaded, 105mm Flanged _ _ _ 0 0.00
Shield 250mm Threaded, 230mm Flanged ** _ _ _ 1 202.00
isolated; Safety: Non-polarity sensitive transmitter; Max. load: 2 Watt; Max.
Length 400mm Threaded, 380mm Flanged ** _ _ _ 2 219.00
switch voltage: 250 VAC/300 VDC; Max. load current: 100 mA; Voltage drop:
Below 1 Volt typical at 50 mA; Time delay (on and/off ): 1-60 seconds. CLS Flange, 3/4” Thread for Mounting
any 3/4” NPT Pointek CLS Level Switch 7ML1500-0_ _0 0.00
V 03.2010
208 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Smart transmitter with patented Active Shield build-up around the mounting glands.
technology and variable frequency oscillator
The CLS500 combines a sophisticated, easy-to-adjust transmitter
• Integrated local display for commis- (MSP-2002-1) with a measurement electrode and process seal designed
sioning and service or remote adjust- to accommodate numerous configurations. The advanced electronics
able programming and control via Hart® and integrated local display provide for one-point calibration without
interrupting the process, and the probe shield design eliminates the
• Analog (2-wire) 4 to 20 mA output
need for frequent recalibration.
Good for use into
• 2-state functionality (4 to 20 Pointek CLS500 can be used as a pump controller, by connecting the
environments up
mA/20 or 4 mA) 2-state mA output and/or the solid state switch to a relay, and activating
• Adjustable hysteresis on/off for 392°F and 7665 PSI! a pump via an auxiliary power circuit.
solid-state output and for cur-
Level Measurement
Standard S-Series (Threaded) Standard S-Series (Flange) • The sum of the active shield length and the measurement length is
the total insertion length
• The active shield design provides continuous immunity from
changes in conditions at the top of the vessel where levels of va-
pors, dust, and condensation may be constantly changing
• The design of the active shield isolates the starting capacitance due
to temperature and pressure fluctuations that could cause small
changes in the seal geometry
• The end seal is formed as an integral part of the electrode insula-
Solids Flow and Motion
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
POINT LEVEL 209
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
cable) Description Number Price
Instrument Valves
Pointek CLS 500, S-series, threaded
ground connection 2-Wire capacitance point level detection instru-
point for instru- 4-20 mA current ment, PFA probe insulation, 316L SS connection 7ML5601- $599.00
ment system loop connection Electronic None 0_ _ _ _ - 0.00
(any polarity) Transmitter MSP2002-1 (330 pF) 1____- 953.00
Process 3/4” Threaded NPT _ AA1 _ - 0.00
Connection 1” Threaded NPT _ BA1 _ - 0.00
Specifications Size 1 1/4” Threaded NPT _ CA1 _ - 0.00
1 1/2” Threaded NPT _ DA1 _ - 0.00
Measurement Range: 0 to 330 pF; Span: Minimum 1 pF 2” Threaded NPT _EA1 _ - 0.00
Measurement Frequency: 420 kHz Approvals General Purpose _ _ _ _1- 0.00
Accuracy: Deviation <0.1% of actual measurement value; Non-Linearity and FM/CSA Approved _ _ _ _ 2- 78.00
Level Measurement
Reproducibility: 0.1% full scale and actual measurement respectively Probe/Electrode Diameter
Instruments
Temperature Stability: Greater of 0.15 pF (0 pF) or <0.25% (typical <0.1%) 16mm Rigid Rod, 1000 mm max length 1_ _ _ - _ 0.00
actual measurement value over full temperature range Rigid Thermal Isolator _ AA0-Z 117.00
Process Connection: NPT thread; ANSI, DIN flat-faced flanges Options Total Insertion Length Y01 _ _ _ _ 3.35/25mm
Process Material: AISI 316 L standard; C 22.8 N, Monel 400, Hastelloy C22, Active Shield Length (50mm Min.) Y02 _ _ _ _ 0.00
Stainless Steel Tag (Max. 20 Char) Y15 (text) 12.00
Duplex optional
Test certificate B (Meets DIN 50049 §3.1
Safety: Current signalling according to NAMUR NE 43; 3.6 or 22 mA, probe and EN 10204) C12 48.00
input ESD protected to 55 kV, inputs/outputs fully galvanically isolated, MSP 2002-1 Transmitter,330 PF 7ML1830-1JP 766.00
polarity-insensitive current loop, fully potted, integrated safety barrier CLS500 Instruction Manual 7ML1998-5GG01 16.00
Diagnostics: Includes fault alarm when primary variable (PV) out of limits,
system failure in measurement circuit, deviation between A/D and D/A Please submit orders to: Siemens Industry Inc,
Flow Measurement
converter, checksum, watch dog and self-checking facility probe
Model Selection Guide c/o Lesman Instrument Company.
Instruments
Catalog
Probe Length: Rod version: Up to 1000 mm (216”) with 16 or 24 mm diameter Description Number Price
probe; Diameter: 16 mm (0.63”) or 24 mm (0.95”) rod
Pointek CLS 500, S-series, welded flange
Probe Installation: PFA, Enamel 2-wire capacitance point level detection instru-
Function Rotary Switch: Positions 0 to 9, A to F ment, PFA probe insulation, 316L SS connection 7ML5602 - $824.00
Remote Communication: HART® Foundation Electronic None 0_ _ _ _ - 0.00
Transmitter MSP2002-1 (330 pF) 1____- 953.00
Pressure Rating: FV to 50 bar (725 PSI), up to 525 bar (7665 PSI) optional
Connection 2” ANSI, 150 lb _ AA1 _ - 0.00
Enclosure: Aluminum, epoxy coated Type 4X/NEMA 4X/IP65; 2 x 1/2” NPT Type and 2” ANSI, 300 lb _AB1 _ - 17.00
cable entry Rating 3” ANSI, 150 lb _ BA1 _ - 40.00
V 03.2010
210 WEIGHT Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
This is the perfect solution to all your level control requirements: Ready to order a load cell?
Sartorius’ revolutionary PanCake® technology for level-by-weight ap-
plications. This system is extremely durable for the utmost precision
Fill out the application datasheet
in most applications. It works independent of material properties and at www.Lesman.com/datasheets
the surrounding environment. Retrofitting is fast and easy. PanCake and fax it back to Lesman.
technology is tried and tested in many installations, and is available at
an affordable price.
Level Measurement
more. In extreme cases this could result in interruption of the associated Load Cell Construction: Hermetically sealed,welded stainless steel construc-
process. New PanCake level-by-weight technology gives extremely ac- tion, filled with Polyurethane
curate readings better than 1% in “real-life” applications over a complete Material: 500kg; 10t: 1.4021 (DIN), 420 S 37 (B.S.); 16t: 1.4542 (DIN), S 604/S
range of capacities up to more than 35,000 pounds. 622 (B.S.), 17 to 4 pH (Int.)
Exceptionally price competitive, the PanCake system offers not only Protection: IP68, IEC 529, equivalent to NEMA 6. The load cell can be sub-
great technical advantages, it also offers exceptional value for the merged in water to a depth of 1.5m for 10,000 hours.
money. Compared to ultrasonic or radar systems, savings of up to 50% Cable: Robust, flexible, screened; Sheath: Thermopl, Elastomer; Color: gray
are possible. (LE: blue, LA/LAC: green); Diameter: 5mm, wires 4 x 0.35 mm2; Length: 5m;
The extremely reliable, tough and durable design of sensors and the Bending radius: ≤ 50mm
use of high quality materials lead to unequaled reliability, even under Certificate of Conformity: EEx ia IIC T6 (PTB Nr. Ex-00.E.2040, II 2G EEx ia II
Flow Measurement
The high quality sensor maintains calibration for years, without drift Technical Data L LA/LAC LE
or creep. The stainless steel housing is hermetically sealed by welding Accuracy Class 0.5%
and complies to the highest rating (IP68) for 10,000 hours at 1.5m (5’), Minimum Dead Load 0%Emax 5%Emax 0%Emax
equivalent to NEMA 6. Safe Overload 150%Emax 100%Emax 150%Emax
PanCake Capabilities Destructive Load 300%Emax
The model LA provides 4 to 20 mA output for direct connection to Rated Output 2.0 16mA 2.0
process instrumentation or PLCs/DCS. Models L and LE featuring mV/V Tolerance on Rated Output < 4
output are connected via Sartorius transmitters and indicators. Usually Tolerance on Zero Signal < 4 4mA <4
Solids Flow and Motion
only one PanCake is required (three legs). If two are used (four legs) you Repeatability Error <0.1
still require only one input channel in your PLC or Process Indicator by Creep During 30 Minutes <0.1
simply switching the two outputs in parallel. Non-Linearity <0.25 <0.25 <0.25
Hysteresis <0.15
Temperature Effect on Zero <0.15%Cn/10K
Temperature Effect on Output <0.1%Cn/10K <0.1%Cn/10K <0.1%Cn/10K
Input Impedance 645±60Ω 645±60Ω
Watch our website for Output Impedance 635±15Ω 635±15Ω
more information Insulation Impedance >5000x10Ω >5000x10Ω
on Sartorius load cells, Recommended Supply Voltage 4 to 21V 20 to 28V 4 to 24V
scales, and precision
Maximum Supply Voltage 32V 28V 25V
batching systems.
Actuator Motors and
Pneumatic Drives
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
WEIGHT 211
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
one sensor for all materials. or changes to the pipework. minutes, by hand rotating the load cell to determine whether or not
Instrument Valves
Easy to start up. No calibration there is a load. Only a minimal 1% of the load is required.
weights required.
No resistors or trim pots in the junction box — Resistors and poten-
tiometers tend to be temperature and moisture sensitive. This can
affect system accuracy.
Matched load cells — All Sartorius load cells are totally matched and
can be replaced without the need for re-calibration.
No influence from the effect of mixers (moving center of gravity)— Due
to matched load cells and unique mounting design
No side load effects due to temperature expansion of the vessel
—Side forces are taken by the mounting kits which have freedom
Example 1: Formation of foam Example 1: The vessel is lifted at one for temperature expansion.
Level Measurement
and bubbles, phase transition and side only. The resulting inclination
evaporation may affect others, but is small enough not to disturb the Load cells have lighting protection — Special strain gauge design in
Instruments
not PanCake. readings. combination with our junction box makes it possible.
Stainless steel and hermetically sealed — The load cells can be sub-
merged in water under 5 feet for 10,000 hours.
Special load cell cable for harsh environments — No PVC insulation,
PTFE is used for high chemical resistance and a Kevlar fiber for “Pull
Protection.”
High Ω load cell design — 650 to 1200Ω input resistance for minimizing
the effect of cabling on accuracy and higher signal under intrinsically
safe conditions
NOW limited LIFETIME WARRANTY on most STAR Line load cells
Flow Measurement
Load cells remain within all specifications up to a usable load of 150
Instruments
to 200% of nominal
Example 2: Material sticking to the Example 2: One leg of the vessel All controls are designed with a built-in test function and can be
wall of a vessel, variable moisture is just shortened by an inch. No “calibrated without weights.”
content and deviations in particle inclination occurs.
size, but PanCake gets it right. We offer a wide range of weighing and batching solutions, from
simple indication to complex batching systems.
Such a small These compression load cells are available with several accuracies:
PR6201 (Left): 0.25% to 0.5%; 0.04% to 0.05%; or 0.015%
solution to a PR6211 (Center): 0.04% to 0.05%
PR6241 (Right): 0.04% to 0.05%; 0.015%; or 0.008%
big problem! Looking for a high accuracy load cell? Call Lesman!
BATCH Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
212 PROCESSING Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
quirements
Instrument Valves
ProBatch+ manages raw materials, creates recipes, and runs and starts Several batches of a recipe can be executed within one production run.
Production plans can be produced for each production line individually
Instruments
1 2 3
Actuator Motors and
Pneumatic Drives
System Architectures
1) Direct serial connection or via the Ethernet. 2) Recipe steps can be carried out directly on 3) Indirect connection via a PLC. PLC functions
Recipe steps are preprogrammed functions a PLC. can be synchronized easily using the control-
of the controller ler’s pre-programmed batch functions.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan BATCH
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
PROCESSING 213
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Instrument Valves
Level Measurement
Process reporting
Instruments
At the end of each recipe run, ProBatch+ generates batch and pro- ProBatch+ controls…
duction reports. Materials management makes reports available on • Maximum 16 batch controllers, 16 parallel running real and logic
consumption, production quantities and stock levels. Because they’re balances, 16 production lines
created using Crystal Reports generator, all reports can be adapted to
your requirements. • Max. 9999 recipes per production line
Batch, production and consumption reports are produced auto- • Max. 9999 components per production line
matically. Volume statistics can be called up easily in respect of time, • 30/20 place recipe name/ID, 30/20 place component name/ID, 3
raw material or product. lines x 30 character + date for raw material batch ID
• Microsoft® Access® database with data security also in ZIP files
Remote Access
Flow Measurement
When you order a remote control license, ProBatch+ control software Production start modes
Instruments
can be accessed, monitored and modified remotely via the Internet and • Start direct on the controller
virtual private networking (VPN).Data can be viewed on multiple monitors, • Start single production
touchscreens, and thin clients. All plant equipment can be displayed with • Start number of batches
animation that shows different equipment status and product flow.
• Start production quantity; automatic calculation of batch quantities
Specifications • Start in accordance with % details
Computing minimum requirements Reports
• Pentium III, 700MHz, 256 MB RAM, 10 GB hard drive • Batch report
• Serial or ethernet interface, USB port for hardware key • Production report
• PC-PLC-Link for Siemens S7-300/400, Phoenix RFC430 For further PLC Basis License, 4 Weighing Points, Hardware Key 9405 384 00111 3550.00
Pneumatic Drives
on request: Allen Bradley in future Upgrade from 4 to 8 Weighing Points 9405 384 00121 1800.00
• PLC support for field bus protocols: Profibus, Interbus, DeviceNet, CC- Upgrade from 8 to 12 Weighing Points 9405 384 00131 1800.00
Link, Modbus Upgrade from 12 to 16 Weighing Points 9405 384 00141 1800.00
Optional Production Plan/Stock Mgmt License 9405 384 00211 1495.00
User access rights Optional DDE Interface License 9405 384 00311 775.00
• Production planning, recipe production, operation, data security Optional Remote Control License 9405 384 00411 775.00
• Report access
Want to learn more about batch processing and recipe
• System functions
management? Call and talk to our product specialist.
LIQUID LEVEL Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
214 TRANSMITTERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Custom cable lengths available on LS-10. LH-10 comes with inte- 0-100”WC 30 PSI 35 PSI 9699711 556.13
gral 40’ cable. 0-150”WC 30 PSI 35 PSI 9699729 556.13
Dimensions 0-250”WC 60 PSI 70 PSI 9699737 556.13
0-400”WC 72 PSI 87 PSI 9699745 556.13
WIKA LS-10 liquid level transmitter is designed
for economical and reliable performance in a va- 0-5 PSI 30 PSI 35 PSI 8371846 556.13
riety of level measurement applications. The LS-10 0-10 PSI 60 PSI 70 PSI 9699754 556.13
0-15 PSI 72 PSI 87 PSI 9736225 556.13
provides a 4-20 mA signal output and an accuracy
0-25 PSI 145 PSI 170 PSI 9699762 556.13
of 0.25% span. 0-50 PSI 240 PSI 290 PSI 9699770 556.13
The high performance LH-10 provides 0.125% ac- 0-100 PSI 500 PSI 600 PSI 9699788 556.13
curacy. The LH-10 includes a dual cable entry design LS-10: 0.25% Accuracy, 316 SS, Polyurethane, Polyamid
that prevents ingress of moisture into the electronics, wetted parts, G1/2B pressure connection, 4-20 mA output.
Level Measurement
even if the cable is damaged. Select cable length below and append to catalog number.
Both models feature watertight vented cable that 0-100”WC 30 PSI 35 PSI 4262761 $392.10
Instruments
can withstand more than 220 pounds of strain. This 0-150”WC 30 PSI 35 PSI 4262779 392.10
means the transmitters can be supported without 0-250”WC 60 PSI 70 PSI 4262787 392.10
the need for additional cabling. 0-5 PSI 30 PSI 35 PSI 4262809 392.10
0-10 PSI 60 PSI 70 PSI 4262817 392.10
Both the LS-10 and LH-10 can be ordered with 0-15 PSI 72 PSI 87 PSI 4262825 392.10
the LevelGuard™ (below) for protection in difficult 0-25 PSI 145 PSI 170 PSI 4262833 392.10
environments. 0-30 PSI 145 PSI 170 PSI 4262841 392.10
0-50 PSI 240 PSI 290 PSI 4262850 392.10
0-100 PSI 500 PSI 600 PSI 4262868 392.10
5’ 4347868 0.00
Need an FM approved intrinsically 10’ 4347876 14.05
Flow Measurement
dirty media
The WIKA LevelGuard attachment is designed for difficult specifications but may lead to adjustable zero/span shifts.
Actuator Motors and
Pneumatic Drives
applications
level sensing applications where sludge, slurry, or turbulence ** Burst pressure, leading to destruction of transmitter.
and turbulent
may be present. Need a cable longer than 100 feet?
processes!
The large 2” diaphragm provides excellent sensitivity and Call for pricing and availability.
performance, even when used to monitor extremely low liquid
levels, or when the assembly is buried in a layer of sludge or
slurry. The cable supplied with the WIKA LS-10 submersible transmitter is designed
to withstand more than 200 pounds of strain, so no additional support or conduit
connections are required.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan LIQUID LEVEL
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
TRANSMITTERS 215
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
wells, tanks, channels, and dams.
Instrument Valves
• 0.3% accuracy On one side of the sensor, the diaphragm is exposed to the hydrostatic
• Easy installation with junction box or cable hanger pressure, which is proportional to the submersion depth.This pressure is
compared with atmospheric pressure. Pressure compensation is carried
Specifications out using the vent pipe in the connection cable.
Measuring Range Maximum Working Pressure The liquid column’s hydrostatic pressure acts on the diaphragm, and
0–2 m (0–6 ft) H2O 1.4 bar (20.3 psi) 14 m (42 ft) H2O transmits the pressure to the sensor’s piezoresistive bridge.
0–4 m (0–12 ft) H2O 1.4 bar (20.3 psi) 14 m (42 ft) H2O
0–6 m (0–18 ft) H2O 3.0 bar (43.5 psi) 30 m (90 ft) H2O Ordering Instructions
0–10 m (0–30 ft) H2O 3.0 bar (43.5 psi) 30 m (90 ft) H2O Select one option from each table following. A complete catalog number
0–20 m (0–60 ft) H2O 6.0 bar (87.0 psi) 60 m (180 ft) H2O looks like this: 7MF1570 - _ _ _ _ _
Zero and Span: Influence of Ambient Temperature: 1–6 m (3–18 ft) H2O:
Level Measurement
0.45%/10 K fullscale;≥6 m (18 ft) H2O:0.3%/10 K full scale;Long-Term Stability: Please submit orders to: Siemens Industry Inc,
1–6 m (3–18 ft) H2O: 0,25% full scale; ≥6 m (18 ft) H2O: 0.2% full-scale Model Selection Guide c/o Lesman Instrument Company.
Instruments
Ambient Operating Temperature: 14°–176 °F (-10°–80 °C) Catalog
Description Number Price
Material: Sensor/Casing: Stainless steel, mat. No. 1.4571/316 Ti; Gasket: Viton;
Connecting Cable: PE/HFFR sheath (non-halogen) SITRANS P MPS Submersible Transmitter for Level 7MF1570 - $0.00
0–2m H2O, 10m Cable 1CA01 449.00
Degree of Protection to DIN EN: IP68 0–4m H2O, 10m Cable 1DA01 449.00
Electrical Connection: Cable with 2 conductors with screen and vent pipe, 0–6m H2O, 25m Cable 1EA01 554.00
strength cord (max. 300 N (67.44 lbf ) Range/ 0–10m H2O, 25m Cable 1FA01 554.00
Cable 0–20m H2O, 25m Cable 1GA01 554.00
Power Supply: Terminal voltage on pressure transmitter: 10–36 V DC Length 0–6 Ft H2O, 32 Ft Cable 1KA01 449.00
Explosion Protection: Intrinsic safety “i” TÜV 03 ATEX 2004X; Identification: 0–12 Ft H2O, 32 Ft Cable 1LA01 449.00
0–18 Ft H2O, 82 Ft Cable 1MA01 554.00
Ex II 1 G EEx ia IIC T4
Flow Measurement
0–30 Ft H2O, 82 Ft Cable 1NA01 554.00
Junction Box: For connecting the transmitter cable; Enclosure: Polycarbon- 0–60 Ft H2O, 82 Ft Cable 1PA01 554.00
Instruments
ate, with vent pipe for atmospheric pressure and screw for cable strength Accessories Plastic Junction Box, IP54 7MF1570-8AA 57.00
cord; Electrical Connection: 2x 3-way (28–18 AWG); Cable Entry: 2x M20x1.5; Carbon Steel Cable Hanger 7MF1570-8AB 15.00
Degree of protection to DIN EN 60529: IP54 Download the SITRANS P MPS operation manual from
Cable Hanger: For mounting the transmitter; Galvanized steel, polyamid www.Lesman.com
Materials: Housing: 316 Cast Stainless Steel, Teflon® coated; Sensing head:
Pneumatic Drives
Two layer diaphragm with Teflon and Buna-N; Exposed materials: 316 cast Learn more about level
stainless steel,Teflon-coated, PVC, synthetic rubber and Urethane; Cable: technology online at
Heavy-duty Polyethylene, vent tube, shielded 18 AWG conductors www.Lesman.com
Atmosphere Ventilation: No-maintenance sealed breather system
No time for on-site training? Check
Power Required: 9-30 VDC (750Ω load @ 24VDC)
out our online training center! View
Call for pressure ranges, cable lengths, and accessories. past training sessions and how-to
Prices start at $1000.00. videos at www.Lesman.com/train
BUBBLER Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
216 SYSTEMS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Common Applications
• Determine head through a flume or weir
91-HF Combination
SITRANS P Pressure Filter-Regulator • Level in a lift station
Transmitters
• Tank level when foam is present
Series 62 Constant • Can be used with atmospheres other than air
Differential Relay
Air Bubbler Theory A bubbler system is an inexpensive but accurate means
of measuring the fluid level in open or vented containers,
1 A constant flow of pressurized air is applied to the tube especially those in harsh environments such as cooling tower
2 A pressure transducer monitors the air pressure in the tube sumps, swimming pools, reservoirs, vented fuel tanks, drain
Level Measurement
3 The pressure in the tube equals the pressure at the tank’s bottom sumps, or air washers.
Instruments
4 The liquid level equals the pressure inside the tube divided by the A complete system consists of a source of compressed
air, air flow restrictor, sensing tube, and pressure transmitter.
liquid’s density The only component of the bubbler system that is exposed
5 As long as the material density remains constant, the pressure is to the elements is the sensing tube. All other components
proportional to the liquid level in the tank can be remotely located in a protected area.
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
TRANSMITTER 217
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Description Model Avail. Price
Instrument Valves
0-25 to 0-400” H2O / 0-25 to 0-1000 mbar STF924- ↓ $1615.00
0-5 to 0-100 PSI / 0-0.35 to 0-7 bar STF932- ↓ 1745.00
0-25 to 0-400" H2O / 0-25 to 0-1000 mbar STF92F- ↓ 1513.00
Pseudo CS Reference Head, 316 SS Vent/Drain Valve,
Flange Barrier Diaphragm, Diaphragm Plate A _ _ • 0.00
Flush 316SS Wetted Parts, Carbon Steel Ref. Head A _ _ • 0.00
Mount All 316 Stainless Steel Wetted Parts E _ _ • 51.00
Extended 316SS Wetted Parts, Carbon Steel Ref. Head M _ _ • 222.00
Mount All 316 Stainless Steel Wetted Parts R _ _ • 272.00
Fill Silicone _ 1 _ • • 0.00
Fluid C T F E _ 2 _ • • 66.00
Level Measurement
Process 1⁄4” NPT Ref. HD, High Pressure Side Flange _ _ A • • 0.00
Conn. 1⁄2” NPT (w/ Adapter), High Pressure Side Flange _ _ H t t 0.00
Instruments
Features
No Selection 0_ _ _ _ • • 0.00
• Flush, flange, extended mounts available Flange 3” ANSI Class 150, Carbon Steel _1_ _ _ • 0.00
• 16:1 or 20:1 turndown ratio 3” ANSI Class 150, 304 Stainless Steel _A_ _ _ • 161.00
3” ANSI Class 150, 316 Stainless Steel _H_ _ _ • 288.00
• 4-20 mA or digital output 4” ANSI Class 150,, 316 Stainless Steel _L_ _ _ • 389.00
• Configurable with Hart® handheld or Honeywell SFC Pseudo 3” ANSI Class 150, Vent/Drain, 316 Stainless Steel _R_ _ _ • 111.00
Flange 3” ANSI Class 300, No Vent/Drain, 316 SS _P_ _ _ • 0.00
Smart Field Communicator
Gasket No Selection _ _0_ _ • 0.00
• Most popular options shown here. Call if you don’t Ring Extended Design, 316 Stainless Steel _ _5_ _ v 0.00
see what you need. No Selection _ _ _00 • 0.00
Flow Measurement
Extension Flush Extension _ _ _ F0 h 0.00
1.87” Diameter, 4” long Tank Spud _ _ _D0 v 144.00
Instruments
Specifications Analog Communications Only (Standard) AN • • 0.00
DE Protocol Communications DE b • • 53.00
Turndown Ratio: STF924, 92F: 16:1; STF932: 20:1 HART® 5,X Field Communications Protocol HC • • 44.00
Recommended Minimum Span: STF924,92F: 25” H2O (37.5 mbar); HART® 6.X Field Communications Protocol H6 • • 50.00
Model STF932: 5 PSI (0.35 bar) Analog Meter (0-100 Even 0-10 Square Root) ME • • 169.00
Smart Meter (Digital) SM b • • 169.00
Zero Elevation and Suppression: No limit (except minimum span)
Local Zero and Span ZS • • 30.00
from 0 Abs. to ±100% URL. Specs valid from -100% to 100% URL.
SIL2 TUV- Certified Transmitter (Requires Options HC/LP) SL • • 0.00
Accuracy: Analog mode: Model STF924,92F: Greater of ±0.10% cali- Write Protection (Delivered in Enabled Position) WP • • 19.00
brated span or upper range value (URV). 0.05 + 0.05(50”H2O/span Lightning Protection LP • • 63.00
“H2O) in % span. STF932,93F: Greater of ±0.10% calibrated span or
V 03.2010
218 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Accurate, affordable level measurement wetted parts are made of stainless steel with a PFA Teflon insulator for
Instrument Valves
wetted parts or pressure variations and material build up. Its advanced electronics
Instruments
• 82 ft. (25 m) maximum insertion length provide for simple calibration, and its integrated local display make
on-site installation and set up easy. The two-wire transmitter complies
• Sanitary rod optional with NAMUR NE 43 for current signaling.
Modular construction features a full range of NPT connections and DIN
Ready to purchase an LC300? Complete and ANSI flanges, as well as corrosion-resistant PFA and 316L stainless
the Siemens capacitance datasheet at steel wetted parts to suit virtually any application.
www.Lesman.com/datasheets and send it The LC300 uses a switched power supply circuit that makes the most
to Lesman with your order. efficient use of available power present on the terminals. If the signal
current is low (4 mA), the terminal voltage will increase due to a voltage
Not sure the LC300 is right for you? Use the drop of other components in the loop. If the signal current is high (20
datasheet to request an engineering review.
Flow Measurement
Specifications Dimensions
Media: Liquids, bulk solids, slurries with a 1.5 minimum dielectric constant Rod Cable/Rope
Measurement Range: 0-3300 pF; minimum span 3.3 pF Version Version
Measurement Frequency: 600 kHz maximum
Accuracy: <0.5% of actual measurement value
Temperature Stability: 0.25% of actual capacitance value
Nonlinearity/Reproducibility: <0.4% /full scale and actual value
Current Signaling: According to NAMUR NE 43, signal 3.8 to 20.5mA, fault
Solids Flow and Motion
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 219
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Ordering Instructions
Make a selection from each table below. A complete catalog number looks like
What’s the Right Level Technology?
this: 7ML5605 - _ _ _ _ _-Z. Siemens requires a completed application datasheet Need help figuring out which level measurement instrumentation
with any LC300 order. See www.Lesman.com/datasheets. to use in your process? Start with the reference charts below. Find
your media type, process conditions, and tank design to
Please submit orders to: Siemens Industry Inc, help narrow down your Key
Model Selection Guide c/o Lesman Instrument Company.
choices. Depending on ▲ Excellent: Recommended.
Catalog Avail- your application,there may l Good: Works in most cases.
Description Number ability
Price
be more than one technol- u Fair: Works, but others are better.
Anderson Greenwood
SITRANS LC300, Threaded Connection 7ML5625 - ↓ $494.00 ogy for you.
Instrument Valves
SITRANS LC300, Welded Flange Connection 7ML5626 - ↓ 494.00 ▼ Poor: Do not use.
Version (For process connections 1-1/4” and larger) Don’t forget to include
Vibratory Fork
Rotary Paddle
Insertion Length (Option Y01_ _ _ _ below.)
Capacitance
Point Level
Ultrasonic
Rod, PFA Insulated, 300–1000 mm 0A _ _ _ - • • 113.00
Rod, PFA Insulated, 1001–2000 mm 1A _ _ _ - • • 223.00 Technologies
Floats
Rod, PFA Insulated, 2001–3000 mm 2A _ _ _ - • • 334.00
Rod, PFA Insulated, 3001–4000 mm 3A _ _ _ - • • 445.00 Media Properties
Rod, PFA Insulated, 4001–5000 mm 4A _ _ _ - • • 555.00 Liquids - Clean l ▼ ▼ ▲ ▲
Rod, PFA Insulated, Stilling Well, 300–1000 mm 0B _ _ _ - • • 278.00 Liquids - Coating ▼ ▼ ▼ l ▲
Rod, PFA Insulated, Stilling Well, 1001–2000 mm 1B _ _ _ - • • 555.00 Slurries ▼ ▼ ▼ l ▲
Rod, PFA Insulated, Stilling Well, 2001–3000 mm 2B _ _ _ - • • 829.00
Liquid/Liquid Interfaces ▼ ▼ ▼ ▲ ▼
Rod, PFA Insulated, Stilling Well, 3001–4000 mm 3B _ _ _ - • • 1106.00
Liquid/Solid Interfaces ▼ ▼ ▼ ▼ ▼
Level Measurement
Rod, PFA Insulated, Stilling Well, 4001–5000 mm 4B _ _ _ - • • 1381.00
Cable, PFA Insulated, Weighted, 1000–2000 mm 0E _ _ _ - • • 65.00 Solids - Low Dust ▼ l l l l
Instruments
Cable, PFA Insulated, Weighted, 2001–4000 mm 1E _ _ _ - • • 127.00 Solids - High Dust ▼ l l l ▼
Cable, PFA Insulated, Weighted, 4001–6000 mm 2E _ _ _ - • • 191.00 Process Environment
Cable, PFA Insulated, Weighted, 6001–8000 mm 3E _ _ _ - • • 252.00 Vapors l ▼ ▼ l ▼
Cable, PFA Insulated, Weighted, 8001–10000 mm 4E _ _ _ - • • 314.00 Foam u ▼ ▼ u ▼
Cable, Non-Insulated, Weighted, 1000–2000 mm 0F _ _ _ - • • 19.00 Temp >350°F ▼ ▼ ▼ ▼ ▼
Cable, Non-Insulated, Weighted, 2001–4000 mm 1F _ _ _ - • • 33.00 Pressure >50PSI l ▼ ▼ l ▼
Cable, Non-Insulated, Weighted, 4001–6000 mm 2F _ _ _ - • • 50.00
Vacuum l ▼ ▼ l ▼
Cable, Non-Insulated, Weighted, 6001–8000 mm 3F _ _ _ - • • 65.00
Cable, Non-Insulated, Weighted, 8001–10000 mm 4F _ _ _ - • • 81.00 Turbulence ▼ ▼ l l l
Tank Design and Structural Properties
Process Connection Size
Agitators ▼ ▼ l l l
3/4” NPT Thread (Rod Versions Only) _ _ A0 _ - • 0.00 Obstructions l l l l l
Flow Measurement
1” NPT Thread (Rod Versions Only) _ _ B0 _ - • 29.00
1.5” NPT Thread _ _ C0 _ - • 65.00
Instruments
Guided Wave Radar
1.25” NPT Thread _ _ K0 _ - • 40.00
1”, ANSI, 150 lb, AISI 316L Stainless Steel _ _ A1 _ - • 217.00
Head Pressure
1”, ANSI, 300 lb, AISI 316L Stainless Steel _ _ A2 _ - • 265.00
Capacitance
1”, ANSI, 600 lb, AISI 316L Stainless Steel _ _ A3 _ - • 278.00 Continuous Level
Ultrasonic
Load Cells
1.5”, ANSI, 150 lb, AISI 316L Stainless Steel _ _ B1 _ - • 262.00 Technologies Bubbler
Radar
1.5”, ANSI, 300 lb, AISI 316L Stainless Steel _ _ B2 _ - • 306.00
1.5”, ANSI, 600 lb, AISI 316L Stainless Steel _ _ B3 _ - • 334.00
Media Properties
2”, ANSI, 150 lb, AISI 316L Stainless Steel _ _ C1 _ - • 311.00
2”, ANSI, 300 lb, AISI 316L Stainless Steel _ _ C2 _ - • 348.00 Liquids - Clean ▲ ▲ ▲ ▲ ▲ ▲ ▲
2”, ANSI, 600 lb, AISI 316L Stainless Steel _ _ C3 _ - • 403.00 Liquids - Coating ▲ ▼ u ▼ l ▲ ▲
3”, ANSI, 150 lb, AISI 316L Stainless Steel _ _ D1_ - • 371.00 Slurries ▲ ▼ l ▼ l ▲ ▲
Vacuum ▲ ▼ l ▲ l ▼ ▲
Pneumatic Drives
V 03.2010
220 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Rod probe versions to 5.5m (18 Ft), and cable probe versions to 35m (115 Ft)
Instruments
Active shield technology provides low initial capacitance for higher The MSP2002 transmitter includes HART protocol for communications
sensitivity in materials with low dielectrics, and higher resolution for and local or remote setup. The HART system provides information on
greater measurement accuracy. Active shield eliminates the drift asso- measured variables, tag numbers, range and span settings, and other
ciated with condensation and stray capacitance buildup between the diagnostic information.
electronics and the measuring surface. Choose from many probe configurations and materials, including
LC500’s accuracy is stated as a percent of the measured value, not as a rigid rod and flow-through electrode models, to find the combination
percent of span or range. This allows for tighter level control, especially perfect for your application.
critical when you’re measuring levels of high-cost products or when The LC500 probe is unaffected by vapors, product deposits, dust, or
your process requires close level tolerances. You’ll be able to more condensation, and it performs in: Liquids oil, water, chemicals, acids,
Solids Flow and Motion
closely monitor maintenance and safety situations, like tank overflows caustics, beverages; Solids granulate, sugar, coal dust, plastics; Interfaces
or hazardous materials backups. high pressure coalescers, glycol regenerators, heater treaters, desalt-
Even with a limited number of probes, the LC500 offers the broadest ers, separators, storage tanks, gas and oil tankers, floating production
range of temperature and pressure applications of any manufacturer in storage offshore (FPSO) ships; Slurries adhesives, paper pulp, glucose,
the industry.Probes can withstand temperature extremes of -328° to 752°F drilling mud
and pressures from full vacuum to 7,665 PSI. The rugged probe design
ensures long life, increased up-time, and reduced maintenance. Active Shield Technology for Accuracy and Reliability
It’s easy to calibrate an LC500 probe.An LC500 can SITRANS LC500 takes you beyond the limitations of traditional ca-
be configured wet or dry with the probe in place, pacitance technologies to provide accurate measurements you can
using switch configuration in the electronics box, depend on.
a Hart® handheld or a Hart HPC01 pocket communicator. Siemens’ patented Active Shield technology isolates the active-shield
The MSP2002 two-wire loop-powered transmitter includes galvanically portion of the probe from the active measurement section.This protects
Actuator Motors and
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 221
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
SITRANS LC500 combines a probe and a two-wire The loop-powered 4-20/20-4 mA signal or the discrete
transmitter as a single instrument. It features a full range output signal of the transmitter can be immediately con-
of probe options and process connections. nected to any DCS system, without using special interface
Custom configurations are available to meet special equipment.
needs for dimension, probe lengths, shield length, process LC500’s microprocessor technology offers high accuracy,
connections, thermo parts, and stilling wells. stability, repeatability, and linearity. Input and output are
polarity-insensitive and completely galvanically isolated.
Anderson Greenwood
Instrument Valves
Standard Combinations of LC500 Probes
Features Series S Series D Series SD Series DD Series HP Interface Sanitary
Process Threaded ✓ ✓
Connection Flanged ✓ ✓ ✓ ✓ ✓ ✓
Types Tri-Clamp ✓
Sanitary Thread ✓
Process Stainless Steel AISI 316L ✓ ✓ ✓ ✓ ✓ ✓ ✓
Connection Carbon Steel C22.8 N ✓ ✓ ✓
Materials Duplex Steel ✓
Hastelloy1 B2 or C22 ✓
Monel 400 ✓
Tantalum ✓
Level Measurement
Probe PFA ✓ ✓ ✓ ✓ ✓ ✓ ✓
Instruments
Insulations PE2 ✓
Ceramic ✓ ✓
Length Max Rod Length 216” 216” 216” 216” 100” N/A 216”
Parameters Max Cable Length 1378” 1378” 1378” 1378” N/A 1378” N/A
Max Pressure3 2900 PSI 2175 PSI 2175 PSI 2175 PSI 7613 PSI 73 PSI 145 PSI
Max Temperature3 392°F 392°F 392°F 392°F 842°F 212°F 392°F
1 Flange made of AISI-316L SS with a 0.19” welded Hastelloy plate. 2 For general purpose applications only. 3 Depends on range.
Specifications
Flow Measurement
Transmitter Process conditions: Temperature rating: -328° to 392°F (-200° to 200°C)
Instruments
Measurement range: 0 to 3300 pF with 3.3 pF minimum span standard, up to 400°C (752°F) optional; Pressure rating: FV to 200 bar (2920
psi) standard, up to 525 bar (7665 psi) optional
Measurement frequency: 420 kHz @ Cx=0 pF
Approvals: CE: Complies with requirements of ECC per
Accuracy: ±<0.1% actual value
EN 55011 and EN 61326; Dust-Ignition Proof: ATEX II 3
Non linearity: <0.1% full scale GD (EEx nA[ib] IIC T6...T4); FM/CSA (CL. I, Div. 2, Grps.
Repeatability: <0.1% actual measurement A–D T4/CL. II, III Div. 1 Grps. E–G T4); Intrinsically Safe:
ATEX II 1 G (EEx ia IIC T6...T4); FM/CSA (CL. I, Div. 1,
Temperature stability: Greater of 0.15 pF (0 pF) or <0.25% (typically < 0.1%)
Groups A–D T4); Explosion-proof enclosure: ATEX II
actual measurement value over the full temperature range
1/2 GD (EEx d [ia] IIC T6...T1); FM/CSA (CL. I, Div.1, Groups A–D T4); Marine:
Safety: ESD protected to 55 kV; Current signaling according to NAMUR NE Lloyd’s Register ENV1, ENV2, ENV3, ENV5; Sanitary: 3A
43; Galvanically isolated inputs/outputs; Polarity-insensitive current loop;
User interface: 4-1/2 digit LCD Integrated local display;Rotary switch;16 menu at www.Lesman.com/datasheets and
items divided between two menu levels: 0 to 9, and A to F; Pushbuttons send it to Lesman with your order.
Communications: HART® protocol; Levelwatch.com for remote inventory Not sure the LC500 is right for
monitoring (optional); Profibus-PA (optional) you? Use the datasheet to request
Environmental: Location: Indoor/outdoor; Altitude: 2000m (6562 Ft) max.; an engineering review.
Ambient temperature: -40° to 185°F (-40° to 85°C) for standard and ATEX XP
T5 to T1, -40° to 158°F (-40° to 70°C) for ATEX T6; Relative humidity: Suitable
for outdoors (Type 4X/NEMA 4X/IP65 enclosure); Installation category: II; Need a HART® handheld communicator or a
Pollution degree: 4 USB to HART modem? See pages 187 and 188.
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
222 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
A good supplier will start by asking you all the details of your applica- don’t hesitate to ask for clarification.
Instrument Valves
tion before recommending a technology or product.Begin your checklist Remember that the quality of the
of application data with information about the material being measured measurement should always be the
– the type, temperature, and any related characteristics. Do you need to foremost priority.
measure level, volume, and/or flow? If you are measuring level in a tank, When selecting a transceiver, make
determine the dimensions and shape of the tank, as well as details about sure it is compatible with the trans-
process connections, internal obstructions, or other considerations. ducer.You can select from rack, panel,
When selecting a transducer, the most important criteria are the or wall mount versions, depending
application’s measuring range and environment. Consider all the envi- on your plant configuration.
ronmental conditions the sensor will experience so you can ensure the Above all, look for models that are easy to install and set up. Com-
model you choose will be suitable and rated for those conditions. Is the missioning is always easier and more secure if the unit uses a handheld
transducer inside a building in a controlled climate, or outdoors in harsh programmer.
Level Measurement
weather conditions?
Some instruments have a swivel head that makes it easy to line up
Instruments
If the transducer is located in blazing sun or is subject to extreme tem- with conduit − a nice feature, especially in tight spaces. Some models
perature fluctuations, consider a sun shield and check that the transducer offer backlit displays for easy readability. This is very useful if you will be
has a temperature compensation feature built in.Is it monitoring corrosive taking readings at the instrument location, but irrelevant if the instru-
chemicals? Are there vapors or foam present? If so, a transducer with a ment is connected to a central monitoring station.
special facing may be needed to ensure compatibility with the material,
hazardous area approvals may be required, or a longer-range unit may Instrument smarts
be needed to compensate for signal attenuation. If the sensor will be More emphasis today is placed on the instrument’s“smarts”or software
installed in a constricted space, you will need a compact instrument. for signal processing and communications.
Will the transducer be submerged in its application, such as in a flooded We know that, to obtain the maximum signal, a transducer should be
wet well? If so, you will need a submergence shield. It will maintain an mounted directly over the material to be measured with the transducer
air pocket in front of the transducer and maintain a high level reading
Flow Measurement
Many applications require continuous monitoring to provide a constant pipes, cables, braces, guide rails, pump cases, and ladders.
readout of the material level at all times. In some cases, however, you may Ideally, you would want to mount the transducer clear of all these
also want to install point level devices as high and low alarms. obstructions but that is very often not possible. Careful mounting and
What power sources are available in the plant? If your application aiming to optimize beam angle can help. A better solution is a system
will be integrated into a control system, how will the transceiver receive with built-in signal-processing software that compensates for these
power? situations.
Once you have assessed all the needs of the application, you can review
Advanced functions
manufacturer specifications to select the products and accessories that
best serve your process needs. When assessing transceiver functions, look beyond the individual ap-
Solids Flow and Motion
capability in the future. Need help finding the right level system
Assessing products for your process?
Look at our Level Technology Selector on page
Using the application details you’ve gathered, assess the appropri-
219 to narrow down your choices. Then, go to
ateness of various ultrasonic products. Main categories to consider
www.Lesman.com/datasheets, download and
are accuracy, repeatability, reliability, features, functions, smarts, and
complete an application datasheet, and fax it
modularity.
to Lesman. We’ll have an engineer review your
Many people confuse repeatability and reliability. Repeatability process and specify the best instrument fit to meet your needs.
describes the ability of the device to distinguish the same level over
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 223
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
• Proven ultrasonic technology
Instrument Valves
Sonic Intelligence™: The Probe provides ultrasonic measurement reliability,
• One-piece design maintenance-free operation, and Sonic Intelligence. Siemens’ advanced
• Easy to install and calibrate software effectively discriminates between real and false echoes to add to
• Measurement reliability the inherent accuracy of the unit. So, the Probe meets your needs in the de-
manding applications where conventional contacting methods can fail.
• Versatile range of options
Simplicity: Bolt, clamp, or screw the unit to the mounting surface above the
• Low maintenance material being monitored.You won’t need to empty the tank.And,unlike load
• Built-in temperature cells, there are no special mechanical considerations. Because the compact
compensation one-piece unit houses both sensor and electronics, you can connect wiring
easily through one of the two cable entry knockouts.
• Two-year guarantee
Two-Step Calibration: Open the Probe’s hinged lid to access the control panel
Level Measurement
for calibration push-buttons and data display. With the material at its cor-
responding 4 mA (low) level, push the 4 button twice. With the material at
Instruments
“Milltronics Probe” its corresponding 20 mA (high) level, press the 20 button twice. That’s it!
Low Maintenance Costs: Probe’s ultrasonics and advanced design lower
maintenance costs dramatically in comparison to competitive technologies.
There are no mechanical moving parts and, as a result, the unit requires no
Siemens brings you an easy way to measure periodic maintenance due to fouling or wear.
liquid levels without the problems of
invasive mechanical devices — The Probe!
Flow Measurement
Measurement Range: 0.8 to 16.4 ft. (0.8 to Make one selection from each table section below. A complete catalog number
Instruments
26.2 ft. for 3-wire models) looks like this: 7ML1201 - _ _ _ _ _
Operating Conditions: Temperature: -40° to
Please submit orders to: Siemens Industry Inc,
140°F (-5°F with metallic mount). Built-in Model Selection Guide c/o Lesman Instrument Company.
temperature compensation. Pressure: 14.5
PSI in vessel max. static. Catalog
Description Number Price
mA Output: Range: 4–20 mA; Accuracy:
The Probe: Ultrasonic Level Transmitter 7ML1201 - $840.00
0.25% target range (air); Resolution: 0.125”;
Loading: 3-Wire: 750Ω max. @ 24 VDC; Measuring 16.5 Feet (5 meter) 1 _ _ _ _ 0.00
2-Wire Loop-Powered: 800Ω @ 28 VDC Range 26 Feet (8 meter) 2 _ _ _ _ 57.00
max. load. Sensor PVDF Copolymer (Kynar Flex), 2” NPT _ E _ _ _ 0.00
V 03.2010
224 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
ing the latest microprocessor and communication technologies.The low noise transmitter and noise
shield result in an excellent signal-to-noise ratio, providing higher accuracy and reliability.
Instruments
You can choose a SITRANS Probe LU with either an ETFE or a PVDF transducer to suit the chemi-
cal conditions of your application. Both have built-in temperature sensors, to compensate for the
varying process temperatures in your application.
Using the handheld infrared programmer, you can set up the unit or change configurations
without ever opening the lid — even in hazardous areas.
Suppression Technology
Instruments
Features
• Patented self-learning algorithm is standard in all Siemens non-
contacting instruments
• No laptop PC or special software required
• Five-minute setup eliminates false echoes
• Accessible via $100 infrared handheld programmer
The Simple Solution
Before
Solids Flow and Motion
Before: The BLUE line represents the echo being returned to the level
Pneumatic Drives
instrument, including all echoes from obstructions. The RED line repre-
sents a default filter applied by the unit to suppress the nominal noise
returned with the echo. The first echo could be from an agitator or tank
brace. The second signal is the data you really want: the reflection from
the surface of the level being measured.
After: The level unit is instructed to“learn”where the obstructions (false
After
echoes) are between the device and the level of the material.The RED line
represents the“learned filter”that is set above the false echoes, screening
them out. All that’s left is the “true” echo from the material surface.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 225
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
moving obstructions in a sludge concentrator
Business Results After Installation
Instrument Valves
made the device unable to provide reliable level
measurement. • The original units were replaced with Siemens
• Meeting Performance Requirements: The contractor responsible SITRANS Probe LU ultrasonic level units. The self-learning feature
was used to ignore the obstructions that produced false echoes.
Read this and other customer success stories Each unit was up and running just 15 minutes after installation.
at www.lesman.com/success/css_application.htm
Level Measurement
Instruments
Flow Measurement
Specifications Ordering Instructions
Instruments
Measuring Range: 10” to 20’ (6M) or 10” to 40’ (12M); Blanking Distance: 10” Make one selection from each table section below. A complete catalog
(0.25M); Beam Angle: 10° at -3 dB boundary number looks like this: 7ML5221 - _ _ _ _ _
Accuracy: Greater of ±0.15% range or ±0.25”; Repeatability: ≤3 mm (0.12”); Please submit orders to: Siemens Industry Inc,
Resolution: ≤3 mm (0.12”) Model Selection Guide c/o Lesman Instrument Company.
Frequency: 54 KHz (ultrasonic) Catalog
Description Number Price
Update Time: <5 seconds
SITRANS Probe LU: Ultrasonic Level Transmitter 7ML5221 - $905.00
Output: 4-20 mA; Accuracy: ±0.02 mA
Measuring 20 Ft (6M) ETFE 2A _ _ _ 58.00
Temperature: Ambient: -40 to 176 °F (-40 to 80 °C); Process temperature at Range 20 Ft (6M) PVDF Copolymer 2B _ _ _ 00.00
flange or threads: -40 to 185 °F (-40 to 85 °C) 40 Ft (12M) ETFE 2C _ _ _ 284.00
using Siemens SIMATIC PDM (PC) or HART handheld communicator, or Note 1: Approval Option 1 only available with Profibus communication
Siemens infrared hand programmer
See page 188 for details and pricing on Simatic PDM.
Programming: Set up for use with as few as two parameters. No echo profile
required at startup; Built-in volume conversion for eight most common Looking for low-cost radar level detection?
tank shapes including custom linearization table See the SITRANS Probe LR on page 240.
Approvals: ATEX Ex II 1 G, EEx ia IIC T4, SIRA certificate 01ATEX2147; ATEX
hazardous area II 1G EEx ia IIC T4; FM Class 1, Div. 1, Groups A-D (barrier
required); Class II, Div. 1, Groups E-G; Class III; CSA Class I, Div. 1, Groups A-D
(barrier required); Class II, Div. 1, Group G; Class III
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
226 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Dual point or single point monitoring option Open Channel Flow Conversion/Totaling ✓
Instruments
• MultiRanger 200 functions include open channel flow moni- Two 4-20 mA Outputs ✓ ✓
toring, volume, pump control, pump volume 3 or 6 Relays, 2 Discrete Outputs ✓ ✓
• Digital communications, with built-in Modbus RTU over 4-20 mA Alternate Level Input ✓
RS485 connection, and easy compatibility with PLCs using RS232/RS485 Modbus Ports ✓ ✓
SmartLinx® interface modules SmartLinx Module Compatible ✓ ✓
• Compatible with Dolphin Plus software for easy parameter
setup, diagnostics, and viewing of echo profiles
• Advanced echo-processing software offers fine-tuning pa- The new generation of Siemens MultiRanger ultrasonic level transceiver
rameters for superior measurement reliability offers unsurpassed reliability, digital communications, and the latest
Flow Measurement
• Improved signal-to-noise ratio for enhanced reliability technology features in a cost-effective package. This multi-functional
Instruments
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 227
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
logical 1 = 10-50 VDC; 3 mA max. draw
Dimensions
Instrument Valves
Outputs: mA outputs: 0-20 mA or 4-20 mA; Transducer drive: 315V peak, 44
KHz; Relays: Three: 2 Form A/ 1 Form C; Six: 4 Form A/2 Form C. (All relays
rated at 5 Amp at 250 VAC, non-inductive.)
Temperature: Compensation: ‑58° to 30°F; Source: Integral transducer sensor,
TS-3 temperature sensor, programmable fixed temperature; Error: Sensor:
0.09% range; Fixed: 0.17%/°C deviation from programmed value
Display: 4” x 1.5” multi-field backlit LCD
Programming: Handheld programmer or PC with Dolphin Plus software
Communication: RS232 running Modbus RTU or ASCII via RJ11 connector,
RS485 running Modbus RTU or ASCII via terminal blocks
Level Measurement
Power Supply: AC model: 100-230 VAC ±15%, 50/60 Hz, 36 VA
(17W); DC Model: 12-30 VDC (20W)
Instruments
Cable: Signal to be 2-3 copper conductors, twisted with
shield (braided screen preferred), drain wire 300V, 0.5mm2
(22-18 AWG)
Enclosure: Polycarbonate Type X/NEMA 4X, IP65
Environment: Indoor/outdoor; Altitude: 6561 ft.; Installation
category: II; Pollution degree: 4
Approvals (Pending): CE, FM, UL Listed; CSA Class I, Div. 2 Grp.
A-D, Class II, Div. 2 Grp. F-G, Class III
Flow Measurement
Need to replace
Instruments
Ordering Instructions
your old MiniRanger Make one selection from each table below. A complete catalog number looks like this:
Plus? Try the 7ML5033 - _ _ _ _ _ - _ _
MultiRanger 100
Single Relay model. Model Selection Guide
Please submit orders to: Siemens Industry Inc,
c/o Lesman Instrument Company.
Catalog
s
See transducer
Description Number Price
on pages
MultiRanger: Transceiver Electronics 7ML5033 - $926.00
A complete level transmitter
234-235.
Model MultiRanger 100, Level Measurement Only 1 _ _ _ _ - 0.00
V 03.2010
Phone: 800-953-7626 • 630-595-8400 Phone: 800-837-1700 • 262-923-1790
MONITORING www.lesman.com
Pressure Transmitters
Discrete: 10-50 VDC switching level; logical 0 = <0.5 VDC, logical 1 = 10-50
Instrument Valves
features advanced relay alarming, differential level measurement, open Communication: RS232 running Modbus RTU or ASCII via RJ-11 connec-
Instruments
flow monitoring, and volume conversion. tor, RS485 running Modbus RTU or ASCII via terminal blocks, SmartLinx®
For water authorities, municipal water, and wastewater plants, HydroR- compatible with RS485 modem kit
anger is an economical, low-maintenance solution delivering control Power Supply: AC model: 100-230 VAC ±15%, 50/60 Hz, 36 VA (17W); DC
efficiency and productivity needed to meet today’s exacting standards. Model: 12-30 VDC (20W)
It offers single-point monitoring with 6 relays standard, as well as digital Transducers: Echomax® series and ST-H series
communications with built-in Modbus RTU via RS485.
Enclosure: Polycarbonate Type X/NEMA 4X, IP65
HydroRanger is compatible with Dolphin Plus, allowing for PC con-
Cable: Transducer and mA output signal to be 2-3 copper conductors, twisted
figuration and setup. Sonic Intelligence® advanced echo-processing with shield (braided screen preferred), drain wire 300V, 0.5 to 0.75mm2
software provides increased reading reliability. (22-18 AWG)
HydroRanger uses Siemens continuous ultrasonic echo ranging tech- Environment: Location: Indoor/outdoor; Altitude: 6561 ft.; Installation cat-
Flow Measurement
nology to monitor water and wastewater of any consistency up to 50 egory: II; Pollution degree: 4
Instruments
XPS-15/15F
XCT-8, XCT-12 Please submit orders to: Siemens Industry Inc,
XRS-5 Model Selection Guide c/o Lesman Instrument Company.
Catalog
For more on Echomax transducers, see pages 234-235. Description Number Price
HydroRanger 200 Wastewater Monitor/Control System 7ML5034 - $1325.00
Dolphin Plus Software Makes Mounting
Wall, Standard Enclosure
Panel Mount
1 _ _ _ _ -
3 _ _ _ _ -
0.00
59.00
Setup a Snap! Input 100 to 230 VAC _ A _ _ _ - 0.00
Laptop Programming: Perform a Voltage 12 to 30 VDC _ B _ _ _ - 0.00
complete setup via an optical link with Feature Single Point System _ _ A _ _ - 0.00
Siemens patented Dolphin Plus Win- Software Dual Point System _ _ B _ _ - 232.00
dows-based software. You can change Data SmartLinx Ready (No Module) _ _ _ 0 _ - 0.00
Actuator Motors and
Pneumatic Drives
any parameter, back up and restore Communi- SmartLinx A-B Remote I/O Module _ _ _ 1 _ - 962.00
parameters to a PC disk, and update the cations SmartLinx Profibus-DP Module _ _ _ 2 _ - 639.00
software in flash memory, all without SmartLinx Devicenet Module _ _ _ 3 _ - 639.00
opening the wiring panel. Approvals CE, CSA, FM, UL Listed _ _ _ _ 1 0.00
Dolphin prompts you with the relevant Handheld Programmer 7ML1830-2AK 125.00
Accessories Dolphin Plus with RS485 to RS232 Link 7ML1841-1AA00 361.00
parameter descriptions and online help needed to program the Dolphin Plus with Comverter 7ML1841-0AA01 442.00
host unit. Complete parameter setup for each unit can be saved Additional English Instruction Manual 7ML1998-5FC02 32.00
to and restored from a floppy disk, or duplicated for programming
multiple units with the same configuration. All models ship with one English user’s manual. *Approvals pending.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 229
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
etwork
Makes N on Easy!
ic ti
a
Commun
Anderson Greenwood
Instrument Valves
Allen-Bradley
Remote I/O
SmartLinx modules
Level Measurement
• Connects directly to standard Allen-Bradley Remote I/O Catalog
Instruments
Description Number Price
(blue hose), Siemens Profibus DP, and Modbus RTU sys-
tems. No extra wiring, boxes, or third-party protocols. SmartLinx Modbus RTU Module
Module for SITRANS LU01/LU02/LU10 7ML1830-1CR $766.00
• Plugs directly into any SmartLinx-ready transceiver. Instruction Manual 7ML1998-1BF01 6.00
• Uses standard PLC data transfer techniques — block SmartLinx for Allen-Bradley Remote I/O Modules
transfer or discrete I/O — with minimum demand on Module for SITRANS LU01/LU02/LU10 7ML1830-1CP 1157.00
Module for Rack and Panel Mount LUC500 7ML1830-1HP 1007.00
PLC resources. Module for Wall Mount LUC500, Accumass BW500
• Provides all status and measurement data from the in- or SF500, MultiRanger 100/200 or HydroRanger 7ML1830-1HS 1077.00
strument. And, in block transfer mode, supports writing Data Disk 7ML1830-1CK 22.00
Instruction Manual 7ML1998-1AP03 11.00
of all appropriate parameters from the control unit.
Flow Measurement
SmartLinx for Profibus-DP Modules
• Can be added later,or switched out for another SmartLinx Module for SITRANS LU01/LU02/LU10 7ML1830-1CQ 769.00
Instruments
module — if you change PLC systems or protocols. Module for Rack and Panel Mount LUC500 7ML1830-1CS 717.00
Module for Wall Mount LUC500, Accumass BW500
or SF 500, MultiRanger 100/200 or HydroRanger 7ML1830-1HR 716.00
With SmartLinx, any Siemens SITRANS LU transceiver can talk to
Data Disk 7ML1830-1CL 22.00
the most popular industrial communication networks — includ- Instruction Manual 7ML1998-1AQ03 6.00
ing the Allen-Bradley Remote I/O or Siemens Profibus-DP. Better
yet, SmartLinx modules connect compatible Siemens transceiv-
ers directly onto the PLC network, so you don’t have to buy or
maintain any intermediary hardware, software, or wiring. Finding the Right Siemens
SmartLinx system operation supports both block transfer and Configuration Tool!
he
oa ters
o
tt he
nd
M
bu tc
Ha
PD
te ch/
Ke iom
works just like the keypad: The host (PLC) writes the parameter
+
rd
Pu ry S
n
d
Po wit
ic
nt
hi
re
lp
fra
ta
m
Do
Ro
Di
Si
buy the SmartLinx-compatible model.When you do want to con- MultiRanger 100/200 3 3 3 Modbus
nect your LU01, LU02, or LU10 into your network, you can order The Probe 3
the SmartLinx module that matches your PLC’s communications SITRANS LU01 3 3
protocol. The module slides directly into the transceiver unit, SITRANS LU02 3 3
and can be installed by qualified personnel whenever you’re
SITRANS LU10 3 3
ready to use it.
SITRANS Probe LU 3 3 Hart
ULS 200 3
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
230 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Replaces...
Instrument Valves
continuous, noncontacting ultrasonic technology. module can be ordered with the unit today or field installed later, so you
have complete flexibility to build the industrial communications network
Instruments
Temperature sensors, built into the Echomax® transducers or mounted you need now or in the future.
separately automatically compensate for changes in sound velocity
caused by temperature changes. The SITRANS LU02 (AiRanger DPL Plus) Faster Scanning, Faster Monitoring: Data — processed up to 10
combines the economy of a single-point unit with the flexibility that times faster than conventional systems — is continuously displayed in
comes with a multi-frequency capability. One monitor to scan liquids, both numeric and icon formats on an easy-to-read LCD.
solids or both, in any two bins of differing size, shape, and configuration. • A bargraph shows rapidly changing levels at a glance.
The electronics are so powerful it is possible to place the unit up to 1200 • Two icons indicate if the vessel is filling or emptying.
feet from its transducers.
• The point number being scanned is visually displayed.
Easy Setup and Operation • Arrows flash when two-way communication is underway (BIC II).
Solids Flow and Motion
The SITRANS LU02 is shipped from the factory pre-calibrated for typical Echomax Transducers: Utterly reliable.Models available to meet wide
liquid and solid applications without the need for detailed setup. Select temperature range requirements. Lower cost of ownership. Echomax
a single parameter to switch between liquid and solid materials, enter transducers are immune to most chemicals and can be installed in the
the bin dimensions and the control unit is up and running. vessel, eliminating the need for elaborate and expensive mounting ar-
rangements. In most cases, the integral temperature sensor eliminates
Simplified Programming the need and cost of a discrete sensor. Echomax transducers can be con-
Fine -tuning for your process is simplified with Quick Start parameters. nected using only shielded, twisted pair, or coaxial cable, substantially
You can program to display either level, space, distance, or volume in reducing wiring costs.
the engineering unit of your choice. Just one entry adjusts the tracking Four Alarm/Control Relays: SPDT relay contact reduces (or eliminates)
speed for changing material levels in any bin. You can view program external relay logic required. Each relay can be programmed indepen-
values during setup and operation, so you don’t have to shut down the dently, with alarm and control functions assigned exactly as you need.
process or switch between different display modes to interrogate it. Independent alarm ON and OFF setpoints for level, temperature, and
Actuator Motors and
Level, temperature, and mA output values can all be selected through rate of change alarms provide maximum flexibility. A fixed 2% hysteresis
Pneumatic Drives
the keypad.The programmer communicates with the electronics through automatically prevents relay chatter for IN or OUT of Bounds alarms.
a noninvasive infrared interface.
Single mA Output: The scalable mA output easily adjusts to suit ap-
Streamlined Communications Solutions plication and controls,reducing external control equipment required.The
You can use the handheld programmer for infrared communication SPL’s single mA output can be programmed for 0-20 or 4-20 mA directly
with the electronics, or configure and diagnose the instrument remotely or inversely proportional, and independently scalable to level, space, dis-
with Siemens’ Windows®-based Dolphin Plus software and a laptop or tance, or volume. You won’t need to buy additional equipment to invert
standard PC. or convert the output to work with other system components.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 231
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Specifications
Range (Level): From 1 ft. to 200 ft. max. Outputs
Accuracy: 0.25% of target range subject to application. Single mA Output: 0-20 or 4-20 mA, scalable 0.1% resolution 350Ω max.
Resolution: Greater of 0.1% of target range or 0.08”. load (common ground) or 750Ω max. load (floating common) or 600Ω
isolated (LIS-1 required).
Memory: EEPROM (non-volatile). No backup battery required.
Relays: Four alarm/control relays; one form C SPDT contact per relay, rated
Programming: Removable magnetic base programmer communicating 5A at 250 VAC, non-inductive.
Anderson Greenwood
through an infrared interface or Dolphin interface.
Instrument Valves
Physical Description
Display
Enclosure: Type 4X/NEMA 4X/IP65 polycarbonate
Panel: Graphic 2” x 5” LCD for measurement readings, operating status. enclosure. 11.2”W x 8.2”H x 3.6”D.
Measurement Reading: Level, space or distance in cm, mm, ft., in., %, or any Approval: CE, CSA (NRTL/C)
other units as programmed. Volume in desired units.
Compatible Transducers: Echomax®: XPS 10,15, 30, 40; XCT 8, 12; XLS 30,
Operating Status: Level bargraph,alarm,data communication,filling/empty- 60; XLT 30, 60; Ultrason®: STH
ing, temperature, rate of change, etc.
Cable: Transducer: RG-62U Coaxial for extensions to 1,200 ft. Run in grounded
Temperature metal conduit,separate from other wiring. TS-3: Belden 8760 2 wire shielded/
Ambient Temperature: -5° to 122°F twisted, 18 AWG or equivalent, good to 1,200 ft.
Compensation: -58° to 302°F. Integral sensor in Echomax® transducers Programmer: Power: 9V (ANSI/NEDA 1604, PP3 or equivalent); Keypad: 20
Level Measurement
compensates for temperature-induced sound velocity variation. keys, tactile feedback; Interface: Noninvasive, infrared.
Instruments
Temperature Error: 0.09% of range with compensation. 0.31% per °F devia-
tion from programmed temperature.
Flow Measurement
6. Aiming kits, software, communications, as needed Catalog
Description Number Price
Instruments
SITRANS LU Long Range Ultrasonic Level Transceivers 7ML5004 - $1939.00
Need help finding the right
Version LU01, Single Point 1 _ _ _ _ - 0.00
level system for your process? LU02, Dual Point 2_ _ _ _ - 244.00
See www.Lesman.com/datasheets for the Siemens
Input Voltage AC, Voltage Selector Switch _A_ _ _ - 0.00
ultrasonic level datasheet. Complete the form and fax it
to Lesman. We’ll have an engineer review your process Software Standard Feature/Application Software _ _ A1 _- 0.00
and specify the best instrument to meet your needs. SmartLinx Ready (No Module) _ _ _ _ 0 - 0.00
Data SmartLinx A-B Remote I/O Module _ _ _ _ 1 - 1157.00
Communi- SmartLinx Profibus-DP Module _ _ _ _ 2 - 769.00
cations SmartLinx Modbus-RTU Module _ _ _ _ 3 - 769.00
V 03.2010
232 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Streamlined Peripheral
Communications Options
Anderson Greenwood
If your processes demand reliable level measurement data in 1 to 10 Noncontacting ultrasonic transduc-
vessels of any shape or size, in any liquid or bulk solid, and in any environ- 234 and
Instruments
the engineering unit of your choice. Just one entry adjusts the tracking have the range for deep, narrow bins up to 200 feet. In liquids or bulk
speed for changing material levels in any bin. You can view program solids, from boiler condensate, to hot tar, they deliver reliability at a
values during setup and operation, so you don’t have to shut down the cost per point that makes them the obvious choice. With increased
process or switch between different display modes to interrogate it. signal sensitivity and a maximum operating pressure of 120 PSI, you
Level, temperature, and mA output values can all be selected through are in control in difficult applications. A beam angle of 5º makes aim-
the keypad.The programmer communicates with the electronics through ing in processes with steep angles of repose less critical for reliable
a noninvasive infrared interface. monitoring. All models have a sealed aluminum face to withstand
noisy, abusive environments.
Command and Control Hermetically Sealed XPS and XCT Series: XPS and XCT units are encapsulated
From the factory to the front office, you can use your laptop computer with chemically resistant Kynar® and hermetically sealed so they can be
for setup and operation with Siemens’software and patented two-way IR immersed, are resistant to steam, and, without glued joints, withstand at-
— without opening the box or making electrical connections.Parameters tack by harsh chemicals. Compact transducers are easily installed without
can be viewed, altered, uploaded to the LU10, or downloaded to disk. flange mounting.
Actuator Motors and
Pneumatic Drives
The Sure Shot XPS Series: Effective to 130 feet, as diverse as bauxite slurry
Faster Scanning, Faster Monitoring and liquid sulfur, four versatile models have excellent chemical immunity
Supported by an internal 16 bit, 16.7 MHz processor, these transceivers and require reduced aiming. For high-dust applications, XPS performance
now process and display data up to 10 times faster than conventional is increased with water-resistant, closed-cell polypropylene foam facing.
systems. All the information you need, in numeric and icon formats, is XCT Series: For extremely hot, corrosive environments, the XCT series are ef-
displayed continuously on the easy-to-read display: a bargraph displays fective in food and chemical applications where contamination is a major
liquid and solid levels at a glance; two icons indicate if the bin is filling or concern. They are food-safe, noncontacting, and immune to most acids,
emptying; the point number being scanned is displayed visually; arrows alkalies, and solvents, with a range to 40 feet.
indicate when two-way communication is active.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 233
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Specifications
Power: 100/115/200/230 VAC ±15%, jumper
selective; 50/60Hz, 15VA.
Channels: Max. 10 active channels per LU10 unit.
Range: 1 to 200 feet, depending on transducer.
Span: 196 ft max., 2” min.
Anderson Greenwood
Accuracy: Greater of 0.25% range or 0.24”; Reso-
Instrument Valves
lution: Greater of 0.1% range or 0.08”.
Temperatures: Operating: -5° to 140°F; Electron- Ideal for tank !
ns
ics: -5° to 122°F; Process: -40° to 300°F farm applicatio
Temperature Compensation: Common temp
sensor input; Option T1B-10 temp sensor input
board to provide independent compensation
per channel.
Volume Conversion: User-selected units for 8
common tank shapes.
Display: 2” x 5” graphic LCD. Two 4-digit 0.7” A complete level system includes: Need help finding the right
numeric displays. 1. Transceiver level system for your process?
Level Measurement
Programmer: Removable, non-intrusive infrared 2. Transducer (see pages 234 and 235) See www.Lesman.com/datasheets for
Instruments
programmer with magnetic retainer, general 3. Additional cable lengths the Siemens ultrasonic level datasheet.
purpose ABS plastic enclosure. 4. Handheld programmer/calibrator Complete the form and fax it to Lesman.
Enclosure: NEMA 4X polycarbonate, stainless 5. Additional electronic modules We’ll have an engineer review your
steel screws; Optional NEMA 7 cast aluminum 6. Optional flanges and aiming kits as needed process and specify the best instrument
7. Software and communications as needed to meet your needs.
Cable: For extensions to 333 ft. total, use 18 AWG
shielded twisted pair cable. For extensions to
1,200 feet max., use RG-62 A/U coaxial cable. Ordering Instructions
Transducer Drive: 44 kHz, 315V peak pulses Make one selection from each table section below. A complete catalog number looks like this:
of max. 1 mSec duration typical; 22 kHz, 150V 7ML5007 - _ _ _ _ _ - 1A
peak pulses of max. 1.7 mSec. duration typical; Please submit orders to: Siemens Industry Inc,
Flow Measurement
or 13 kHz, 150V peak pulses of max 1.7 mSec. Model Selection Guide c/o Lesman Instrument Company.
duration typical; Max. repetition rate: 200
Instruments
mSec/transmit. Catalog
Description Number Price
Analog Output: Programming only, no on-
SITRANS LU10 Long-Range Ultrasonic Level Transceiver Electronics 7ML5007 - $4592.00
board output. Optional modules.
Input Voltage AC, Voltage Selector Switch 1_ _ _ _ - 0.00
Data Link: Transmit only; Single ±20 mA bi-polar
current loop @ 4800 baud. 10,000 feet max Software Standard Feature/Application Software Packs _ AA _ _- 0.00
loop. Loading: 3 peripheral devices max. SmartLinx Ready (No Module) _ _ _ 0 _ - 0.00
Relay Outputs: Programming only, no on-board Data SmartLinx A-B Remote I/O Module _ _ _ 1 _ - 979.00
relays. Optional SAM-20 satellite alarm module. Communications SmartLinx Profibus-DP Module _ _ _ 2 _ - 651.00
SmartLinx Modbus-RTU Module _ _ _ 3 _ - 651.00
Display: 1 power/comms status LED; 20 relay Additional SITRANS LU AO Instruction Manual 7ML1998-5CE01 6.00
Pneumatic Drives
status LEDs (SAM-20). Instruction SmartLinx Allen-Bradley Remote I/O Instruction Manual 7ML1998-1AP03 11.00
Manuals SmartLinx Profibus DP Instruction Manual 7ML1998-1AQ03 6.00
Memory: 10 minutes minimum data retention. SmartLinx Modbus Instruction Manual 7ML1998-1BF01 6.00
Operating Temperature: -5° to 140°F
Enclosure (HWD): Standard open polycarbonate
board (7.6” x 10.2” x 2.3”); Optional NEMA 4X
polycarbonate board (8.2” x 11.2” x 3.6”).
Interconnection Cable: Belden 8760, 1 pair
shielded/twisted, 18 GA.
ULTRASONIC Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
234 TRANSDUCERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Echomax Ultrasonic Level Transducers Please submit orders to: Siemens Industry Inc,
c/o Lesman Instrument Company
6° 2 to 100 Ft -40 to 203°F 1.5” NPT Thread XPS-30 30M 7ML1123-0EA50 1163.00
Instrument Valves
sonic system: 150º C (300º F) 6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15-6 10M 7ML1118-0CD30 1048.00
6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15-6 30M 7ML1118-0ED30 1085.00
• Uniformity as close as 1 foot,
Instruments
• Chemically resistant 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10-6 30M 7ML1115-0EE30 1007.00
• Hermetically sealed models For Corrosive and Wet Applications: Blue Kynar Housing, Teflon-Coated Aluminum Sensor Face. ATEX, FM Approvals.
immune to dust, steam, turbu- 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10T-3 5M 7ML1115-2BC30 872.00
lence, corrosives 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10T-3 10M 7ML1115-2CC30 900.00
• Aiming is less critical 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10T-3 30M 7ML1115-2EC30 941.00
12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10T-4 5M 7ML1115-2BD30 905.00
• 1” NPT conduit connection with 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10T-4 10M 7ML1115-2CD30 933.00
NEMA 4 ingress protection 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10T-4 30M 7ML1115-2ED30 971.00
(except XRS-5, which has IP68 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10T-6 5M 7ML1115-2BE30 1043.00
rating) 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10T-6 10M 7ML1115-2CE30 1071.00
Solids Flow and Motion
• Models available with CSA, FM, 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10T-6 30M 7ML1115-2EE30 1109.00
CE, 3A, and FDA approvals 6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15T-6 5M 7ML1118-2BD30 1117.00
6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15T-6 10M 7ML1118-2CD30 1142.00
6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15T-6 30M 7ML1118-2ED30 1179.00
For Hazardous Environments: Blue Kynar Housing, Aluminum Sensor Face. FM (Class 1, Division 1) Approval.
12° 1 to 33 Ft -40 to 203°F 1” NPT Thread XPS-10F 5M 7ML1170-1BA10 720.00
12° 1 to 33 Ft -40 to 203°F 1” NPT Thread XPS-10F 10M 7ML1170-1CA10 748.00
12° 1 to 33 Ft -40 to 203°F 3” ANSI Flange XPS-10F-3 5M 7ML1170-1BB10 902.00
12° 1 to 33 Ft -40 to 203°F 3” ANSI Flange XPS-10F-3 10M 7ML1170-1CB10 930.00
12° 1 to 33 Ft -40 to 203°F 8” ANSI Flange XPS-10F-8 5M 7ML1170-1BE10 1112.00
12° 1 to 33 Ft -40 to 203°F 8” ANSI Flange XPS-10F-8 10M 7ML1170-1CE10 1140.00
6° 1 to 50 Ft -40 to 203°F 1” NPT Thread XPS-15F 5M 7ML1171-1BA10 864.00
6° 1 to 50 Ft -40 to 203°F 1” NPT Thread XPS-15F 10M 7ML1171-1CA10 889.00
Actuator Motors and
Don’t see the process connection or cable length you need? Call us!
Need an aiming kit
or field mounting Catalog Catalog
hardware for your Aluminum Easy Aimer Kits Number Price 304SS Easy Aimer Kits Number Price
level sensor? NPT, 1.5” Galvanized Coupling* 7ML1830-1AN $103.00 NPT with 1.5” Coupling 7ML1830-1AT $452.00
NPT, 1” Galvanized Coupling 7ML1830-1AP 103.00 NPT with 1” Coupling 7ML1830-1AU 452.00
NPT, 3/4” x 1” PVC Coupling 7ML1830-1AQ 103.00 Easy Aimer User Manual 7ML1998-5HG62 6.00
* For use with XPS-30 or XPS-40 transducers only.
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
TRANSDUCERS 235
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
10° 1 to 16.5 Ft -4 to 149°F 1” NPT Thread XRS-5 10M 7ML1106-1BA20-0A 463.00
Instrument Valves
10° 1 to 16.5 Ft -4 to 149°F 1” NPT Thread XRS-5 30M 7ML1106-1CA20-0A 497.00
10° 1 to 16.5 Ft -4 to 149°F 3” ANSI Flange XRS-5-3 5M 7ML1106-1AA20-0B 590.00
10° 1 to 16.5 Ft -4 to 149°F 3” ANSI Flange XRS-5-3 10M 7ML1106-1BA20-0B 613.00
10° 1 to 16.5 Ft -4 to 149°F 3” ANSI Flange XRS-5-3 30M 7ML1106-1CA20-0B 647.00
For High Temperature Corrosive and Wet Applications: White Kynar Housing, Aluminum Sensor Face. ATEX, FM, • Built-in temperature com-
CENELEC, and FDA Food-Grade Approvals. pensation automatically
adjusts for velocity variations
12° 1 to 26 Ft -40 to 293°F 1” NPT Thread XCT-8 1M 7ML1132-0AA40 741.00
12° 1 to 26 Ft -40 to 293°F 1” NPT Thread XCT-8 10M 7ML1132-0CA40 781.00 caused by air temperature
12° 1 to 26 Ft -40 to 293°F 1” NPT Thread XCT-8 30M 7ML1132-0EA40 870.00 changes in the vessel, ensuring
6° 1 to 40 Ft -40 to 293°F 1” NPT Thread XCT-12 1M 7ML1136-0AA30 915.00 optimum accuracy from ‑4º to
6° 1 to 40 Ft -40 to 293°F 1” NPT Thread XCT-12 10M 7ML1136-0CA30 954.00 149º F (‑20° to 65º C)
6° 1 to 40 Ft -40 to 293°F 1” NPT Thread XCT-12 30M 7ML1136-0EA30 1041.00 • Narrow beam pattern with
Level Measurement
For FM Class I, Div 1 Liquid and Solid Applications, including Hazardous, Corrosive and Wastewater Environments. negligible side lobes gives
Instruments
Tefzel Base and Lid Epoxy Fitted Joint). CE, CSA, CENELEC Approvals. reliable performance over full
12° 1 to 33 Ft -40 to 164°F 2” NPT Thread ST-H 5M 7ML1100-0AA20 776.00 temperature range, even in
12° 1 to 33 Ft -40 to 164°F 2” NPT Thread ST-H 10M 7ML1100-0BA20 807.00 narrow tanks.
12° 1 to 33 Ft -40 to 164°F 2” NPT Thread ST-H 30M 7ML1100-0CA20 850.00 • Low ringing cuts blanking
distance to a minimum, so you
Don’t see the process connection or cable length you need? Call us! can use the full tank capacity
and eliminate the need for tall
Mounting Brackets for Ultrasonic Sensors standpipes
• Closed cell foam is immune
FMS-200 Universal Box Bracket Kit Includes Order to moisture and temperature-
Flow Measurement
7ML1830-1BK independent
Allows any unit with a threaded 1”or 2”connection Two 1” mounting nuts
$102.00
Instruments
to be mounted 8” to 12” out from a wall or beam. One 2” mounting nut • High sensitivity across the
Box design also acts as a sun shield. transducer face improves
performance on solids and is
FMS-210 Wall Mount Channel Bracket Kit Includes Order especially effective for long
Allows any transducer with a threaded 1” con- Four 1/4” lock washers
7ML1830-1BL shots up to 200 feet
$143.00 • Self-cleaning, low mainte-
nection to be mounted 5” to 19” out from a wall Two 1” mounting nuts
or beam. Two 2” mounting nuts nance. Condensation, liquid,
Four M6x12 bolts and dust won’t build up on the
active transducer face
FMS-220 Extended Channel Bracket Kit Includes Order
nection to be mounted from 19” high and from Six M6x12 bolts
Pneumatic Drives
16” to 43” out past the mount.. Two M6x30 bolts ULS200 (FMS-200 Only)
One M8x50 bolt XPS-15 XPS-10
FMS-350 Floor Mount Kit Includes Order XPS-15F XPS-10F
Bridge Channel Bracket 7ML1830-1BQ XCT-12 XCT-8
Four 1/4” lock washers
$557.00
Allows any transducer with a threaded 1” con- Two 1” mounting nuts XRS-5 ST-H
nection to be mounted from 19” high, anywhere Twelve M6x12 bolts
along a 65” beam. Great for open channel flow Three M6x30 bolts
applications by providing a very stable mount for Two M8x50 bolts Echomax mounting
the transducer above a flume or weir.
RADAR Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
236 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Is your current contacting level technology undependable, signals, even in tanks and silos with coned bottoms
Instrument Valves
When was the last time you installed a new radar unit? How parameters and less than five minutes — and reprogram
long did it take? Have you ever had it configured and working the unit without a factory guy, if your needs change
Instruments
in less than four minutes? ✔ Models for any application, from simple liquid storage
Did you know that for less than $1000, you can buy a radar unit tank monitoring to bulk solids and tall tanks — with
that works in liquids for vessels up to 66 feet? prices starting under $1000!
True
Level
Siemens LG200 False
Echo
Echo
• Horizontal cylinders
• Measuring in side pipes or bypass
• Liquid interfaces
Actuator Motors and
Pneumatic Drives
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
LEVEL 237
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Instrument Valves
Level Measurement
Instruments
SITRANS Probe LR/LR200 SITRANS LR250 SITRANS LR400
Function Two-wire loop powered pulse radars for bulk Two-wire pulse radar level transmitter for Long range FM radar for difficult applications,
liquid chemical storage in simple process continuous monitoring of liquids and slurries low dielectric liquids, or narrow vessels
vessels and tank farms. in storage and process vessels. requiring a smaller beam angle.
Range 66 feet (20 meters) 66 feet (20 meters) 164 feet (50 meters)
Frequency 6.3 GHz 25 GHz 24 GHz FMCW
Process Probe LR: -40° to 176°F) -40° to 320°F (using process connection with -40° to 382°F, option allows use to 482°F
Temperature LR200: -40° to 392°F FKM O-ring)
Flow Measurement
Process Probe LR: To 43.5 PSI To 580 PSI To 580 PSI
Instruments
Pressure LR200: To 580 PSI
Dielectric >3 (for <3 use waveguide antenna or >1.6, horn and application-independent >1.6
Constant stillpipe
Accuracy ± Greater of 0.1% range or 10mm ±0.02 mA ≤5mm at 2m to 10m, ≤15mm at 10m to 50m
Output Probe LR: 4-20 mA, HART® 4-20 mA, HART or Profibus PA, NE 21, NE 43 4-20 mA, HART or Profibus PA,
LR200: 4-20 mA, HART or Profibus PA, NE 21, 1 relay
NE 43
Communi- HART (Both) or Profibus PA (LR200 only), HART or Profibus PA, SIMATIC PDM for HART or Profibus PA, SIMATIC PDM for
imide lid; Type 4X/NEMA 4X, Type 6/IP68; protection: Type 4X/NEMA 4X, Type 6/NEMA Ingress protection: Type 4X/NEMA 4X, Type
Pneumatic Drives
Siemens requires a completed radar application datasheet with any radar instrumentation order.
See www.Lesman.com/datasheets
TWO-WIRE Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
238 PULSE RADAR Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Making Radar Work for Liquid and Slurry Level Monitoring Specifications
Siemens’ SITRANS LR250 two-wire 25 GHz radar level transmitter Frequency: 25 GHz (k-band)
measures liquids and slurries in vessels up to 20 m (66 ft). Measurement Range: Minimum: 2” from the end of the horn; Maximum: 65
The LR250 is the easiest to install and quickest to configure on the feet (20m), depending on horn size
market today. With its narrow beam and small antenna, SITRANS LR250 Non-repeatability: 0.2” (5 mm)
Flow Measurement
can be installed practically anywhere on your vessel. Dielectric Constant: >1.6, horn and application dependent
Instruments
The small horns (1.5” to 4” models) allow for installation in existing Output: 4 to 20 mA; Accuracy: ±0.02 mA
openings, and the concentrated high-frequency beam ensures minimal
Failsafe: Programmable as high, low, or hold (loss of echo); NE 43 program-
interference from the vessel walls.
mable
The Quick Start Wizard guides you through programming the transmit-
Power: 24 VDC nominal, 30 VDC max.
ter using a few key parameters, so the LR250 can be measuring in minutes.
The transmitter can be programmed using the intrinsically safe handheld Display: Local graphic interface with Quick Start Wizard and echo profiles
programmer, or remotely via HART® — without opening the transmitter Programming: SIMATIC PDM or Intrinsically safe infrared handheld
lid and exposing the electronics to aggressive atmospheres. Communication: HART®;PROFIBUS PA optional
Process Intelligence evaluates dynamic echo signals. It applies al- (Profile 3.0, Class B)
Solids Flow and Motion
gorithms (based on field data collected from more than a million level
Process Conditions
measurement applications) to raw echoes, to produce accurate and
reliable measurement readings. It can automatically ignore obstructions, Temperature: Ambient: -40° to 80°C (-40° to 176°F); Process: -40° to 302°F
and is the processor behind the advanced diagnostic tools, the Quick (-40° to 150°C) at process connection with FKM O-ring
Start Wizard, and automatic false-echo suppression. Sonic Intelligence Pressure (vessel): 40 bar g (580 psi g) max., dependent on temperature and
significantly improves the measurement accuracy in low level vessels process connection
and low dielectric media.
Design
Enclosure: Die-cast aluminum, polyester powder-coated; Ingress Protection:
Type 4X/NEMA 4X,Type 6/NEMA 6, IP67, IP68; Cable Inlet: Two 1/2" NPT inlets;
Process Connections: 1.5" or 2" NPT
Horn Antenna: Material: 316L Stainless steel [optional alloy N06022/2.4602
(Hastelloy® C-22® or equivalent)]; Sizes: 1.5", 2”, 3”, or 4” nominal (40, 48, 75,
Actuator Motors and
Pneumatic Drives
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
PULSE RADAR 239
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Instrument Valves
Nominal Horn Horn Beam Measuring
Horn Size OD Height Width Range
1.5” 1.57” A 3.93” 19° 32.8’
2” 1.88” B 5.18” 15° 65.6’
3” 2.94” C 6.48” 10° 65.6’
4” 3.73” D 8.64” 8° 65.6’
Level Measurement
Instruments
Ordering Instructions
Make one selection from each table section below.A complete catalog number
will look like this: 7ML5431-_ _ _ _ 0 - _ _ _ _
Don’t forget to order a handheld programmer and a manual.(Quick-start guide
included with each unit.) Siemens radar application datasheet required with order.
See www.Lesman.com/datasheets.
Flow Measurement
Sitrans LR250 Two-Wire 25GHz Pulse Radar 7ML5431- $2025.00
Instruments
Process 316L Stainless Steel, PTFE Emitter, FKM Seal 0 _ _ _ _- 0.00
Connect./ 316L Stainless Steel, PTFE Emitter, FFKM Seal 1 _ _ _ _- 182.00
Antenna Hastelloy C-22, PTFE Emitter, FKM Seal [1] 2 _ _ _ _- 1482.00
Material Hastelloy C-22, PTFE Emitter, FFKM Seal [1] 3 _ _ _ _- 1664.00
Process 1.5” NPT Taper (ANSI/ASME B1.20.1) [2] _ AA _ _- 0.00
Connect. 2” NPT Taper (ANSI/ASME B1.20.1) [2] _ AD _ _- 50.00
Type 2” ASME, 150 Lb _ BA _ _- 209.00
2” ASME, 300 Lb _ CA _ _- 242.00
3” ASME, 150 Lb _ BB _ _- 320.00
3” ASME, 300 Lb _ CB _ _- 352.00
V 03.2010
240 PULSE RADAR Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Initial setup and configuration can be completed with as few as two parameters —
with no need for an echo profile.
• Program using intrinsically safe handheld programmer, Simatic
t
Prices star! PDM software and a PC, or HART® handheld communicator. You
at 906.0 0 don’t have to open the cover — exposing the terminals to the elements and corrosion.
• Built-in display has a primary reading, an auxiliary reading and a level bargraph.
• Rotating head swivels to line up with conduit or wiring connections. After installation,
just rotate the head to the desired position for easy display viewing. After orientation,
the head can be locked into place for permanent use.
• “Uni-construction” polypropylene rod antenna. The threads and rod antenna are made
Level Measurement
Probe LR (left) has a plastic of the same material, and hermetically sealed to prevent chemical ingress. The internal
Instruments
enclosure — ideal for chemical shield ensures that no nozzle noise is introduced by the installation.
applications. LR200 (right) has • Flange adapter version offers optional process connections and antennae.
an aluminum enclosure. • Advanced Sonic Intelligence signal-processing software includes Auto False-Echo Sup-
pression for automatic detection and suppression of echoes from tank obstructions.
• Rugged, encapsulated enclosure is submersible and corrosion resistant. The potted
design provides an extremely high level of shock and vibration resistance.
Dimensions
Flow Measurement
Probe LR and LR200 are designed for safe and simple basic operation. You can make
programming,using the intrinsically safe hand program- parameter changes using the hand
Instruments
mer, without having to open the instrument’s lid. Both programmer, a HART® handheld
units offer a standard uni-construction, hermetically communicator, or with a PC and
sealed, polypropylene rod antenna that offers excellent Siemens Simatic PDM configura-
chemical resistance. tion software.
A local alphanumeric display is standard to all models. An echo status indicator ensures that your echo is
A primary display shows engineering units or percent of reliable. If the echo confidence drops below the echo
level,distance,or volume;a secondary display shows mA, confidence threshold, the failsafe timer starts running.
temperature, signal status, faults, and parameter values, When the timer expires, a Loss of Echo status shows on
and an active bargraph reports material level. the display. When a valid reading is received, the level
Solids Flow and Motion
Startup is easy, with as few as two parameters for reading display returns to normal operation.
Specifications
Range: 66 ft. (20m) Antenna:Hermetically sealed polypropylene rod.Standard:
Frequency: 6.3 GHz 100mm (4”) shield for max. 100mm (4”) nozzle; Optional:
250mm (10”) long shield; Rod: Teflon® (PTFE); Other
Dielectric Constant: >3 (for <3 use waveguide antenna antenna types available; Purge optional
or stillpipe)
Enclosure: Probe LR: PBT polymer, hard-coated polyether
Accuracy: ± greater of 0.1% range or 10mm; Repeat- imide lid; Type 4X/NEMA 4X, Type 6/IP68; LR200: Alumi-
ability: ±5mm num,polyester powder-coated;Type 4X/NEMA 4X,NEMA
Analog Output: 4 to 20 mA ±0.02 mA accuracy max. 550Ω 6, IP67 protection
Actuator Motors and
Local Display: Multi-segment alphanumeric liquid crystal Temperature: Ambient: -40° to 176°F (-40° to 80°C);
with bar graph (representing level) Process: -40° to 392°F (-40° to 200°C) process conn.
Communications: HART®,Infrared handheld programmer, type-dependent
SIMATIC PDM Vessel Pressure: Up to 40 bar (600 PSI) process con-
Process Connections: 1.5” NPT, BSP, or G (polypropylene), nections type-dependent SITRANS Probe LR
flanges, sanitary Approvals: CE,CSAUS/C,FM,ATEX,Industry
Canada, FCC, R&TTE, 3A
Dielectric constants table available on page 484. LR200
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan TWO-WIRE
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
PULSE RADAR 241
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Catalog
Description Number Price
Instrument Valves
Description Number Price
Sitrans Probe LR: PBT Enclosure, 2x0.5” NPT Cable Inlet 7ML5430- $906.00 Sitrans LR200 Flange Adapter Horn Antenna Version 7ML5425- $1445.00
Antenna 1.5” NPT, Integral 100mm Shield 1A _ _ _ 297.00 Antenna 316L Stainless Steel, PTFE Cone Emitter 0 _ _ _ _- 0.00
1.5” NPT, Integral 250mm Shield 1D _ _ _ 406.00 1000 mm Sliding Waveguide, (Note 5) 2 _ _ _ _- 586.00
Approvals FM, CSA General Purpose _ _ B _ _ 0.00 Process 2” ANSI 150 Lb, FF Flange (Note 4) _ FB _ _- 108.00
(Note 3) FM Class I, II, III, Div 1, Grps A–G Connect. 3” ANSI 150 Lb, FF Flange _ GB _ _- 145.00
Intrinsically Safe (with Suitable Barrier) _ _ D _ _ 166.00 (316 SS) 4” ANSI 150 Lb, FF Flange _ HB _ _- 216.00
Output Hart Communications and 4-20 mA _ _ _ 10 0.00 6” ANSI 150 Lb, FF Flange _ JB _ _- 418.00
8” ANSI 150 Lb, FF Flange _ KB _ _- 747.00
Output Hart Communications and 4-20 mA _ _ _0 _- 0.00
SITRANS LR200 Uni-Construction Rod Antenna Process FKM _ _ _ _ 0- 0.00
Catalog Seal Nitrile (Sliding Waveguide Systems) _ _ _ _ 1- 0.00
Level Measurement
Description Number Price Horn 80mm Horn for Stillpipe Applications 0B _ _ 406.00
Instruments
Sitrans LR200 Uni-Construction PP Rod Antenna Model 7ML5422- $1105.00 Size 100mm Horn for Stillpipe Applications 0C _ _ 406.00
150mm Horn 0D _ _ 406.00
Antenna Polypropylene,
200mm Horn 0E _ _ 406.00
Type Integral 100mm Shield, 1.5” NPT 2A _ _ _ 323.00
100mm Horn, 150mm Extension 0G _ _ 747.00
Approvals FM General Purpose _ _ B _ _ 0.00 150mm Horn, 150mm Extension 0L _ _ 747.00
FM Class I, II, Div 1, Grp A–G, Intrinsic Safe _ _ D _ _ 172.00
Approval FM, CSA General Purpose _ _ B _ 0.00
FM Class I, Div 2, Grp A–D _ _ F _ _ 0.00
FM Class I, II, III, Div 1, Grp A–G _ _ J _ _ 201.00 Pressure Per Pressure/Temp Curves in Manual _ _ _ 0 58.00
Rating 0.5 bar (7.5 PSI) Maximum _ _ _ 1 0.00
Output Hart Communications and 4-20 mA _ _ _ 10 0.00
Also available with 300# flange process connections and
waveguide extensions. Call for price and availability.
SITRANS LR200 Rod Antenna, Flange Connection
Flow Measurement
Catalog SITRANS LR200 also available in sanitary model.
Instruments
Description Number Price Call for model selection and pricing assistance.
Sitrans LR200 Flange Adapter, PTFE Teflon Rod Antenna 7ML5423- $1445.00
Process 2” ANSI 150 Lb, FF Flange 1FB _ _- 511.00
Conn. 3” ANSI 150 Lb, FF Flange 1GB _ _- 707.00 Accessories — All Models
(316 SS) 4” ANSI 150 Lb, FF Flange 1HB _ _- 931.00 Description Catalog Number Price
1.5” NPT Threaded 1LA _ _- 495.00 IS/Infrared HART® Handheld Programmer 7ML5830-2AH $125.00
2” Threaded 1MA _ _- 524.00 IS/Infrared Profibus Handheld Programmer 7ML5830-2AJ 125.00
Antenna None _ _ _ 0 _- 0.00 RS-232 HART® Modem for Simatic PDM/PC 7MF4997-1DA 439.00
Extension 50mm PTFE Extension _ _ _ 1 _- 54.00 USB HART® Modem for Simatic PDM/PC 7MF4997-1DB 499.00
100mm PTFE Extension _ _ _ 2 _- 66.00
V 03.2010
242 TANK LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
PA optional
Instruments
Featuring four-wire power and a frequency of 24 GHz, SITRANS LR400 SITRANS LR400 is virtually unaffected by vapors, high pressure, or ex-
Flow Measurement
is the superior radar solution for level measurement of liquids in harsh treme temperatures often found in chemical and petrochemical industries.
Instruments
environment applications up to 147 feet.This high-power,high-frequency Its self-calibration reference system ensures repeatability. The narrow
instrument is ideal for level measurement on storage vessels used in the beam angle allows for greater flexibility in mounting locations.
cement,power,chemical,and petrochemical industries.It uses frequency-
modulated continuous wave (FMCW) radar technology combined with FMCW and Superior Echo Processing
advanced signal processing for accurate, reliable performance. The radar instrument transmits a linear,
Auto-setup makes startup easy with its eight menu-driven steps. Se- frequency modulated, continuous wave. It
lect individual parameters from the menu using the infrared hand-held compares the return signal to the transmit-
programmer. You can also use a PC and Simatic PDM software for easy ted signal, where the difference in frequency
remote programming. Installation is simple and usually without inter- is directly related to the measured distance.
ruption to your process. The infrared hand-held programmer lets you A fast fourier transformation (FFT) process
Solids Flow and Motion
program the LR400 wirelessly from up to two meters away. converts the frequency spectrum of the signal
into an echo profile.Siemens Milltronics applies
Simatic PDM (Process Device Manager) is the ideal software tool for
special advanced algorithms — including au-
configuration, parameter settings, record-keeping and diagnostics, in-
tomatic false-echo suppression — to the profile
cluding trend and echo profiles. PDM offers communication by HART®,
to establish the correct level readings.
Profibus PA, and other protocols. See page 188 for more details.
You can learn more about Siemens’patented
Precise Liquid Level Measurement automatic false-echo suppression algorithms
A high signal-to-noise ratio combined with the high frequency provides and self-learning features on page 224.
superior results in level measurement on liquids. LR400 is especially ef-
fective on low dielectric liquids, such as solvents, petrochemicals, oils or
liquefied petroleum gas (LPG) — even without a stillpipe.
Actuator Motors and
Pneumatic Drives
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
TANK LEVEL 243
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Catalog
Repeatability: ≤ 1mm
Instrument Valves
Description Number Price
Failsafe: mA signal programmable as high, low or hold (LOE) SITRANS LR400 for Liquid Storage Vessels 7ML5421- $3331.00
Analog Output (HART): HART®, Optically isolated 4 to 20 mA signal Process ‑40° to 284°F 0 _ _ _ _ - 0.00
Load: Max. 600 Ω Temperature ‑40° to 482°F Temperature Extension 1 _ _ _ _ - 312.00
Communication: HART or Profibus PA (Layer 1 and 2, Class A, Profile 3.0) 3” Universal Flat Face (Note 1) _ A _ _ _ - 115.00
4” Universal Flat Face (Note 1) _ B _ _ _ - 168.00
Digital Output: Relay, normally open or closed function, max. DC 50 V, max. 6” Universal Flat Face (Note 1) _ D _ _ _ - 239.00
200 mA, rating 5 W 3”, ANSI 150 lb. Class, Raised Face _ E _ _ _ - 198.00
Dielectric Constant: >1.4 3”, ANSI 300 lb. Class, Raised Face _ F _ _ _ - 288.00
Process 4”, ANSI 150 lb. Class, Raised Face _ J _ _ _ - 251.00
Rated Conditions Connection 4”, ANSI 300 lb. Class, Raised Face _ K _ _ _ - 359.00
Ambient Temperature: -40 to 149 °F (-40 to 65 °C) 6”, ANSI 150 lb. Class, Raised Face _ N _ _ _ - 323.00
Level Measurement
Process Temperature: Standard: -40 to 392 °F (-40 to 200 °C); -4 to 392 °F (-20 Antenna Long, 3.66” Diameter, for 4” Nozzles _ _ D _ _ - 0.00
Instruments
to 200 °C) for SITRANS LR 400 with ATEX rating; With temperature extension: Horn Short, 2.9” Diameter, for 3” Nozzles _ _ K_ _ - 0.00
-40 to 482 °F (-40 to 250 °C) Purging None _ _ _ 0 _ - 0.00
Option Antenna Purging System (Note 1) _ _ _ 1 _ - 263.00
Vessel Pressure: Up to 40 bar (process connection dependent)
Process PTFE for ‑40° to 482°F Flange _ _ _ _ 1 - 84.00
Location: Indoor/outdoor; Installation Category: II; Pollution Degree: 4 Seal/Gasket FKM for ‑4° to 392°F Flange (Note 2) _ _ _ _ 3 - 0.00
Design Output HART, 4 to 20 mA 0 _ _ _ 0.00
Power Supply: 120–230 VAC ±15% (50/60 Hz), 6 W (12 VA) or 24 VDC +25/- Profibus PA 1 _ _ _ 275.00
20%, 6 W Power 120 to 230 VAC, 2 x 1/2” NPT _ C _ _ 0.00
Supply 24 VDC, 2 x 1/2” NPT _ F _ _ 109.00
Weight: Approx. 12.2 kg (26.8 lbs) with 3” 150 PSI flange
Approvals CSA, General Purpose _ _ B _ 0.00
Enclosure: Painted diecast aluminum; IP67/Type 4X/NEMA 4X,Type 6/NEMA
Flow Measurement
FM, Hazardous Locations (Note 2) _ _ T _ 300.00
6; M20 x 1.5 or ½” NPT (QTY 2) cable inlets
Display Local Display _ _ _ 2 0.00
Instruments
Antenna: Stainless steel, PTFE emitter; Short (2.9” diameter) or long horn
(3.66” diameter), optional purge and PFFE lens dust cover Accessories
Intrinsically Safe Infrared Handheld Programmer 7ML5830-2AJ 125.00
Process Connections: 316 stainless steel flat-faced flanges, 80, 100, 150 mm,
PTFE Dust Cover, Long Horn 7ML1930-1AH 133.00
bolt holes matching DIN 2527 and JIS B 2238; 316 stainless steel raised-face RS-232 HART® Modem for PC/Simatic PDM 7MF4997-1DA 439.00
flanges, 3”, 4”, 6”, bolt holes matching ANSI B 16.5 USB HART® Modem for PC/Simatic PDM 7MF4997-1DB 499.00
Certificates and Approvals: Safety: CSAUS/C, CE, FM; Radio: Europe (R&TTE, English Operation Manual 7ML1998-5FH06 11.00
CETECOM), Industry Canada, FCC; Hazardous Areas: ATEX II 1/2G EEx dem LR400 Quick-Start Manual 7ML1998-5QN83 16.00
[ia] IIC T6; ATEX II 1/2G EEx dem IIC T6; CSA/FM Class I, Div. 1, Groups B-D; Note 1: Units with universal flat face flange process connections require antenna
Class II, Div. 1, Groups E-G; Class III T6 purging system.
Windows®-based software
Pneumatic Drives
Display: Local Alphanumeric See page 188 for details on Siemens’ Simatic
LCD for readout and entry PDM software and accessories.
BULK SOLIDS Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
244 RADAR LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Advanced diagnostic and cost-saving maintenance liquid asphalt cement (AC) in a ratio of approximately
features — Significantly improved diagnostic messag- 5% AC to 95% solids. LR260 was chosen for the ap-
ing means fewer and more meaningful error codes are plication because material build-up and the destruc-
generated,so you can define which errors are important tive nature of the aggregate caused problems for
and direct the error codes to where they are needed. contacting probes. Intense heat created temperature
stratification, causing ultrasonics to fail. High and
• Enhanced EDD with quick-start wizard for use with
low point level switches didn’t provide the required
SIMATIC PDM. Advanced built-in features, including
continuous monitoring.
the ability to save echo profiles.
New built-in maintenance timers improve maintenance The 25 GHz high frequency of the LR260 provided
cycle efficiency by letting you schedule cleaning or good reflection on materials that vary in particle
Flow Measurement
replacement activities with automated alerts that size. Measurement is now virtually unaffected by dust,
originate directly from the device. temperature, and vapor.
Instruments
Picking the Right Siemens Radar for Measuring Bulk Solids Level
LR260 LR460
Method 25 GHz pulse radar 24.2 to 25.2 GHz FMCW Radar
Range 98 feet (30 m) 328 feet (100 m)
Solids Flow and Motion
Power Nominal 24 VDC, 30 VDC max, 4-20 mA 100-230 VAC ±15%, 50/60 Hz, 6W (12A) or
Profibus PA: 15.0 mA 24 VDC +25/-20% 6W optional
Media Dielectric er >1.6 Dielectric constants table er >1.4
Constant available on page 484.
Process Connections Universal: 2”, 3”, 4”, or 6” with integral EasyAimer Universal: 3”, 4”, or 6” with integral EasyAimer
Horn Antenna 2”, 3”, or 4” diameter horn, 3” or 4” diameter horn,
optional dust cover, optional 1/8” NPT purge connection optional dust cover, optional 1/8” NPT purge connection
Process Conditions Ambient: -40° to 176°F; Process: -40° to 392°F Ambient: -40° to 149°F; Process: -40° to 392°F
Approvals General: CSA us/c, CE, FM General: CSA us/c, CE, FM
Radio: FCC, Industry Canada, European (R&TTE), C-TICK Radio: FCC, Industry Canada, European (R&TTE), C-TICK
Hazardous Areas: CSA, FM, ATEX, IEC Ex Hazardous Areas: CSA, FM, ATEX, IEC Ex
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan BULK SOLIDS
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
RADAR LEVEL 245
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Instrument Valves
Level Measurement
Instruments
Specifications Ordering Instructions
Measuring Principle: 25 GHz K-band pulse radar Make a selection from each table section below. A complete catalog number
Detectable Distance: 0.05m (2”) minimum from end of horn will look like this: 7ML5424-0_ _ _0 - _ _ _0. Don’t forget to order a handheld
programmer and a manual. (One quick-start guide is included with each unit.)
Measuring Range: 2” horn: 10m (32.8 ft) max.; 3” horn: 20m (65.6 ft) max.; 4” Application datasheet required with order. See www.Lesman.com/datasheets
horn: 30m (98.4 ft) max.
HART® Output: 4 to 20 mA (±0.2 mA accuracy); Nominal 24 VDC (max 30 Please submit orders to: Siemens Industry Inc,
VDC); Fail signal: 3.6–23 mA or last value; Load: 230–600Ω, (230–500Ω when Model Selection Guide c/o Lesman Instrument Company
connecting to a coupling module); Line length: Multiwire, ≤1500m (4921 Catalog
Flow Measurement
ft) max; Protocol: HART Version 5.1 Description Number Price
Instruments
PROFIBUS PA Output: Per IEC 61158-2, 15.0 mA; Profile V3.01, Class B Sitrans LR260 Two-Wire 25GHz Pulse Radar 7ML5427- $1959.00
Accuracy: 25mm (1”) from minimum detectable distance to 300mm (11.8”); Process Universal Flat Faced 3” (80mm) 0A _ _ _- 232.00
Remainder of range: Greater of 10 mm (0.39”) or 0.1% span.Accuracy includes Connect. Universal Flat Faced 4” (100mm) 0B _ _ _- 232.00
Universal Flat Faced 6” (150mm) 0C _ _ _- 297.00
hysteresis and non-repeatability
Antenna 3” Horn, Fits 3” Nozzles _ _ F _ _- 0.00
Operating Conditions: Ambient temperature: -40° to 176°F; Process tempera- 3” Horn, 100mm Extension _ _ G _ _- 105.00
ture: -40° to 392°F; Process pressure: 7.25 PSIG max (0.5 bar) standard, 43.5 3” Horn, 200mm Extension _ _ H _ _- 209.00
PSIG (3 bar) optional with 176°F max temperature; Installation category: 1; 3” Horn, 500mm Extension [1] _ _ J _ _- 522.00
Pollution degree: 4 3” Horn, 1000mm Extension [1] _ _ K _ _- 1044.00
Media Dielectric Constant: er >1.6, antenna and application dependent 4” Horn, Fits 4” Nozzles _ _ L _ _- 0.00
4” Horn, 100mm Extension _ _ M _ _- 105.00
V 03.2010
246 RADAR LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
excellent reflection from solids • Process Intelligence Echo Processing: Differentiates between
true echoes from the material and false echoes generated by
• Process Intelligence for advanced obstructions. Dynamic threshold adjusts automatically to changing
echo processing and quick, easy conditions in the vessel. The result is repeatable, fast and reliable
adjustment measurement, even through severe dust.
• Extremely high signal-to-noise ratio • Digital Communications: HART®; PROFIBUS PA (option available
yields high performance mid-2007); Connectivity with commonly used communications
• 328 ft (100m) range for long-range buses makes for flexible networking with a DCS or PLC.
and difficult applications • Infrared Handheld Programmer: No need to open the device for
programming. Intrinsically safe for hazardous areas. Make changes
• Built-in Easy Aimer for optimizing signal on without interrupting your process or exposing electronics to the
Level Measurement
• Self-guided quick start wizard for fast simple • Enhanced Electronic Device Description (EDD) with Quick Start
setup — in just eight parameters Wizard: One of the first instruments to have an Enhanced EDD file
• Program using infrared intrinsically safe that can be used in configuration software, like SIMATIC PDM and
handheld programmer or HART handheld Emerson AMS. A number of new advanced features are built in,
including, easy-to-use graphical Quick Start Wizard and the ability
device and SIMATIC PDM to save echo profiles. The quick start wizard is also available via the
• Dynamic TVT threshold automatically ad- infrared handheld programmer.
justs echo detection sensitivity depending • Advanced Diagnostic and Maintenance Features: Significantly
on echo strength improved diagnostic messaging means fewer and more meaningful
error codes are generated, so you can define which errors are im-
Flow Measurement
portant and direct the error codes to where they are needed. New
built-in maintenance timers improve maintenance cycle efficiency
Instruments
LR460 Visit lesman.com for Siemens full by letting you schedule cleaning or replacement activities with
specifications on radar products.
automated alerts originating from the device itself.
feeding into the furnace, and leading to time-consuming and on one furnace and it worked well
costly furnace shutdowns. enough to implement this solu-
Burden level is extremely critical in the “charging” process, not tion for all the blast furnaces in
only for proper throughput, but to maintain proper cooling and the plant. Accurate level measure-
prevent hot spots for occurring on the shell. A hot spot could ment is so important that two
eventually cause a breakout of molten iron, causing serious injury LR400s will be used on each of the
— not to mention weeks of unscheduled downtime. four furnaces for redundancy.
• Installing a Siemens non-contact
Current Business Result radar solution to measure burden
• Broken Equipment: The existing cable and weight system would level has increased production,
hang up, and the cable would break frequently. reduced furnace shut-downs, and improved product consistency.
• High Cost of Downtime: The engineers estimate lost-ore costs Customer Comment
Actuator Motors and
furnace) and $20,000 (largest furnace). A typical unscheduled Since we installed the first LR400s, we’ve had no unscheduled shut-
shutdown for repair would last no less than two to three hours, downs caused by burden level problems. When we figured out the
and would usually occur three to four times per year per furnace. savings, it was substantial.
A fully integrated mill needs to make iron to produce the final On our small furnace, it’s between $72,000 and $144,000 per
steel product, so costs will escalate considerably if a furnace stays year. On our biggest furnace, we’re saving between $120,000
on unscheduled shutdown and interrupts steel production. and $240,000 per year.
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
RADAR LEVEL 247
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
The ability to penetrate dust makes the LR460 ideal for applications into an echo profile. Siemens applies special
Instrument Valves
on flour, fly-ash, carbon black, powders, and other dusty materials. High advanced algorithms — including automatic
power, high frequency, and a narrow beam angle combine to produce false-echo suppression — to the profile to
excellent reflection characteristics and exceptional measurement per- establish the correct level readings.
formance on virtually any solids medium, regardless of particle size.
Easy, Flexible Programming Options
LR460’s integral Easy Aimer allows for easy positioning for optimum
Safe on-site local programming is simple, using the Intrinsically Safe
measurement on solids.An optional dust cap is available for sticky solids.
handheld programmer. Auto-setup makes startup easy with its eight
An air purge option is available for extremely sticky applications.
menu-driven steps. Use the infrared handheld programmer to select
FMCW and Superior Echo Processing individual parameters from the menu. Installation is simple, and con-
figuration changes can be made without interrupting your process.
Built-in Process Intelligence echo processing ensures reliable dynamic
echo evaluation of challenging solids applications. Unparalleled signal Simatic PDM (Process Device Manager) is the ideal software tool for
remote configuration, parameter settings, record-keeping and diag-
Level Measurement
amplitude gives reliable readings on long ranges, sloped surfaces, and
low dielectric media. nostics, including trend and echo profiles.
Instruments
Specifications Ordering Instructions
Frequency: 24.2 to 25.2 GHz FMCW radar ts table Make a selection from each table section below. A complete catalog number
Dielectric constan 484.
Range: 1.15 to 328 feet (0.35 to 100 m) available on page will look like this: 7ML5424-0_ _ _0 - _ _ _0. Don’t forget to order a handheld
programmer and a manual. (One quick-start guide is included with each unit.)
Medium: Dielectric constant εr>1.4 Application datasheet required with order. See www.Lesman.com/datasheets.
Accuracy:Non-Linearity:Greater of 1”(25mm) or 0.25% span;Non-Repeatability:
≤ 0.4” (10 mm) Please submit orders to: Siemens Industry Inc,
Model Selection Guide c/o Lesman Instrument Company
Analog Output: Optically isolated 4 to 20 mA, 600 Ω max load; Failsafe: MA
Catalog
Flow Measurement
signal programmable as high, low or hold (loss-of-echo) Description Number Price
Instruments
Digital Output: Relay, NC or NO function, max. 50 VDC, 200 mA, rating 5 W Sitrans LR460 Four-Wire 24GHz FMCW Radar 7ML5426- $3062.00
Communication: HART; PROFIBUS PA optional Process Universal Flat Faced 3” (80mm) 0A _ _ _- 232.00
(pending) Layer 1 and 2, Class A, Profile 3.01 Connect. Universal Flat Faced 4” (100mm) 0B _ _ _- 232.00
Universal Flat Faced 6” (150mm) 0C _ _ _- 297.00
Operating Conditions
Antenna 3” Horn, Fits 3” Nozzles _ _ A _ _- 0.00
Temperature: Ambient temperature for enclosure: -40° to 149°F (-40° to 65°C); 3” Horn, 100mm Extension _ _ B _ _- 105.00
Process temperature: -40° to 392°F (-40° to 200°C) 3” Horn, 200mm Extension _ _ C _ _- 209.00
Vessel Pressure: 7.25 psi (0.5 bar) max. 3” Horn, 500mm Extension [1] _ _ D _ _- 522.00
3” Horn, 1000mm Extension [1] _ _ E _ _- 1044.00
Materials 4” Horn, Fits 4” Nozzles _ _ F _ _- 0.00
Learn more about the LR460. Get full specs, manuals, quick-start guides,
and application tips at www.Lesman.com/get/lr460.php
GUIDED WAVE Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
248 RADAR LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
• Easy setup – Three-button pushbutton configuration for quick setup. HART® communi-
Instrument Valves
process conditions, high temperatures and pressures, and steam. For short and extended applications,
LG200 offers coaxial, single or twin rod probes, and single or twin cable probes up to 75 feet.
Instruments
The wide selection of models and the echo processing software ensure reliable measurement in
liquids with corrosive vapors, foam, saturated steam, high viscosity, surface agitation, high fill/empty
rates, low tank levels and varying dielectric or density.
Guided wave radar combines time-domain reflectometry (TDR), equivalent time sampling (ETS), and
modern low power circuitry. TDR uses pulses of electromagnetic energy to measure distances or levels.
When a pulse reaches a dielectric discontinuity created by the medium’s surface, part of the energy is
reflected. The greater the dielectric difference, the greater the amplitude (strength) of the reflection.
In the SITRANS LG200, a waveguide with a characteristic impedance in air is used as a probe.
When part of the probe is immersed in a medium other than air, it creates a lower impedance
a SITRANS
Ready to order out Siemens discontinuity, it generates a reflection.
(due to the increased dielectric.) When an EM pulse sent down the probe meets the dielectric
Flow Measurement
Fi ll
LG200 system? n datasheet
Instruments
io
LG200 applicat
ETS is a critical key in the application of TDR-to-vessel level measurement. The high speed EM
om /d at as he et s energy (1000 ft/ms) is difficult to measure over short distances at the resolution required in the
.c
at www.Lesman Lesman for process industry. ETS captures the EM signals in real time (nanoseconds), and reconstructs them
and se nd it to in equivalent time (milliseconds), which is much easier to measure with today’s technology.LG200
ew.
engineering revi takes about eight scans per second, and each scan gathers more than 30,000 samples.
pharmaceuticals, semiconductors,
Pneumatic Drives
3A approval
Interface Measures both upper liquid level Corrosion Aggressive media
ts table
and interface level Dielectric constan 484.
avail ab le on pa ge
Overfill Measures 100% full point of a High Viscous materials
tank temperature,
high pressure
Flexible for Bulk solids ranges up to 75 ft
solids
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan GUIDED WAVE
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
RADAR LEVEL 249
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Instrument Valves
Level Measurement
Instruments
Flow Measurement
Instruments
Medium Applications with Applications Liquid
range solids steam or ammonia with turbulence interfaces
Condensed Specifications
Measurement Range: Up to 75 ft
Linearity: Coaxial/Twin rod probes: Greater of <0.1% of probe length or
0.1”; Single rod probes: Greater of <0.3% of probe length or 0.3”; Interface
via HART®
Pneumatic Drives
Power: 11 to 36 V DC
Enclosure: Type 4/NEMA 4/IP65 epoxy-coated aluminum, two 1/2” NPT
cable inlets
SITRANS LG200 is compatible with
Windows-based SIMATIC PDM software
Process Conditions: Ambient temperature: -40 to 176 °F; Process temperature:
-320° to 800° F, probe dependent; Vessel pressure: Full vacuum to 6250 PSIG, for configuration and management.
probe dependent See page 188 for Simatic PDM software
Approvals: CSAus/c, CE, FM, 3A for general service; CSA, FM, ATEX for haz- and communication accessories.
ardous areas
250 INVENTORY BY Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan
V 03.2010
Phone: 800-953-7626 • 630-595-8400 Phone: 800-837-1700 • 262-923-1790
SERVO GAUGE www.lesman.com
Pressure Transmitters
simple startup.
Instruments
Industry Approvals
Honeywell Enraf systems are approved
worldwide by national weights and mea-
sures authorities and by customs and excise services. Honeywell Enraf the weight of the partly immersed displacer will be in balance with the
servo tank gauging systems have set the standard for officially certified programmed weight as measured by the force transducer.
automatic tank gauging systems such as those approved by the American When the storage tank is emptied, as the liquid level starts to fall, the
Petroleum Institute and International Standardization Organization for upward force on the displacer will decrease. The force transducer will
the installation and operation of automatic tank gauging systems, and actuate the servo controller so the measuring drum unwinds,allowing the
the International Organization of Legal Metrology and the Netherlands displacer to descend until it again becomes partly immersed in the liquid
Metrology Institute for the performance requirements relating to those and its apparent weight corresponds to the programmed weight.
Flow Measurement
systems.
Measuring Interface Levels
Instruments
Intelligent Software
Reliable Measurement Principle Honeywell Enraf servo gauges are fully microprocessor controlled tank
Honeywell Enraf servo tank gauging systems are based on a proven level gauges. All instrument functions are driven by means of intelligent
measurement concept. Level measurement is performed by a displacer, software, which filters out possible imperfections thereby optimizing
a strong and flexible measuring wire, a measuring drum, force transducer measurement accuracy.
and servo motor. In addition, the software compensates for hydrostatic deformation of
The weight of the displacer ensures that the wire is constantly ten- the tank. This method, without a standpipe, ensures an extremely high
sioned, even on turbulent liquid surfaces, avoiding measurement errors degree of accuracy.
caused by displacer drift.
The level measurement is performed by lowering the displacer on
Simple Installation and Fast Startup
the measurement wire down into the liquid. It will be partly immersed Honeywell Enraf servo gauging systems are designed for easy installa-
because the displacer has a greater density than the liquid. In accordance tion. Electrical cabling and mechanical installation are quick and simple
Actuator Motors and
with Archimedes’ principle, the weight of the displacer will diminish by to perform. The systems are attached by a 2” mounting flange.
Pneumatic Drives
the weight of displaced product. The weight of the displacer less the In order to simplify the startup, calibration and servicing procedures
weight of displaced product — the apparent weight — then serves as as much as possible, the portable Honeywell Enraf terminal can be in-
unit of measurement to determine the displacer position, and measure terfaced with an optical infrared port. This device enables these jobs to
the level of the liquid. be performed quickly, while bypassing the central system.
A highly accurate and advanced force transducer continuously mea-
sures the apparent weight of the displacer. That apparent weight can
be simply programmed by software settings. In the equilibrium state,
Illinois, Indiana, Missouri, and Iowa Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan INVENTORY BY
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
SERVO GAUGE 251
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
Instrument Valves
Level Measurement
Instruments
Description Servo Gauge 854 ATG Servo gauge 854 XTG
As tank gauging has evolved, the series 854 ATG servo level Honeywell Enraf offers the 854XTGH servo gauge as a
gauge has become an industrial standard all over the world. superior alternative to mechanical float and tape gauges or
Very reliable, versatile and accurate automatic tank gauge other low-cost level measuring devices. The 854XTG servo
with a minimum of moving parts, meeting all international gauge offers the proven accuracies and performances of the
standards, regulations and recommendations. 854 ATG, without the local display.
Measuring Range Standard: 0–88 ft (0–27 m); Optional: 0–121 ft (37 m), 0–115 ft (0-35 m) with measuring wire up to 492 ft (150 m)
Accuracy Level: ±0.016” (4 mm) Level: ±0.04” (1 mm)
Density: ± 0.19 Lb/Ft3 (3 Kg/m3) Density: ± 0.31 Lb/Ft3 (5 Kg/m3)
Flow Measurement
Interface: ±0.08” (2mm) Interface: ±0.08” (2mm)
Temperature: ±0.18° F (0.1°C) Temperature: ±0.18° F (0.1°C)
Instruments
Sensitivity/Repeatability: ±0.004” (0.1mm) Sensitivity/Repeatability: ±0.004” (0.1mm)
Wave Integration Programmable, three setpoints, between 0.5 s and 10 s
Operating M/C versions: Up to 90 PSI (6 bar) Up to 90 PSI (6 bar)
Pressure H version: Up to 600 PSI (40 bar) in accordance to PED
Ambient -40° to 149°F (-40° to 65°C)
Temperature
Protection Class NEMA 4/IP65 according to EN 60529
Options Two SPDT 3-Amp alarm relay outputs; Density measurement; 4-20 mA level output (accuracy to ±0.1% full scale);
Input boards for spot RTD, VITO probes for average temperature and/or water measurement, HART® devices (e.g., transmitters);
Modbus RS-232 or RS-485 data transmission
V 03.2010
252 GAUGING Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
airtight, and the integrated display is intrinsically rection of the amplification factor,
Instruments
safe. All basic functions are instantly available automatic amplification monitoring,
through the flip-top display. The display zone-identification and ullage-cor-
can show basic parameters and 24-hour rection. So, not only can the FlexLine
trends. In addition to the standard display, be installed close to the tank wall,
an extra display can easily be connected to but objects and other elements that
the SmartRadar FlexLine. cause disturbances (like sealants) do
SmartRadar FlexLine tank gauging systems come not influence signal processing qual-
in three versions: FlexLine XP for the strictest custody ity. Even a deviation in the diameter
transfer requirements, FlexLine HP for standard custody of the still-pipe length or clogging is
transfer and FlexLine AP for transit and intermediate storage tanks. compensated by EPS technology.
Flow Measurement
continually monitored at component level.The diagnostic monitoring require ullage of 0.5 to 1 m (20”to 40”),
functions support a proactive maintenance strategy and contribute to SmartRadar FlexLine requires only 30 cm (12”).
a further simplification of remote service.
Open Communication
Enhanced signal processing capabilities SmartRadar FlexLine systems are equipped with a broad set of com-
Honeywell Enraf’s latest Enhanced Performance Signal (EPS) Process- munications protocols,including Honeywell Enraf’s field-proven Bi-Phase
ing makes it possible, even under the most difficult circumstances, to Mark (BPM) communications, the de facto standard for field communica-
measure the level with extreme precision. tion in tank terminals.
A comprehensive array of input/output (I/O) options also includes
SPDT alarm outputs. Field equipment, like pressure transmitters, HART
instrumentation and VITO probes for temperature or spot measuring
can be easily connected to the SmartRadar FlexLine.
Actuator Motors and
Pneumatic Drives
V 03.2010
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
GAUGING 253
Pressure Transmitters
Fax: 630-595-2386 sales@lesman.com Fax: 262-923-1797
Anderson Greenwood
standards for tank level measurements, (±0.04”) makes the FlexLine HP ideal for custody tanks. The AP system satisfies OIML R85 and
Instrument Valves
including API, ISO, OIML and NMi. The XL tank transfer. It has a measuring range of 75 m (246 API’s recommended practices. Depending on
gauging system, with a measuring range up ft) and satisfies all essential standards for tank the antenna type, the measuring range of the
to 75m (246 ft), lends itself to Weights-and- level measuring, including API, ISO, and IML. FlexLine AP is 75 m (246 ft).
Measures regulated customs transfer.
Flame-proof
SmartView enclosure with
antenna contamination is essential toward display (option) hinged cover
trusting the maximum reliability of the
measuring equipment at all times.
Level Measurement
The antennae are further enhanced
by the absence of mechanical alignment
Instruments
equipment, standard on parabola or horn
antennae. The result is a reflection signal
that ensures a higher degree of accuracy.
Planar antennae can be used on tanks for
level measuring free space or measuring
on still pipes. A special hinged antenna allows assembly through a FlexConn
6” opening, so you can measure close to the tank wall without losing expansion
modules
reliability and accuracy. Honeywell Enraf’s tank separator enables easy
installation of all antennae. Antenna
SmartRadar components and accessories also include antennae for Connection
Flow Measurement
applications in open spaces, still pipes and in areas of high pressure and
Instruments
high temperatures.
Antenna Types Condensed Specifications
Free space antennae: Planar free space antennae can be mounted on a Measuring Range: Up to 75 m (246ft); Resolution: 0.1mm (0.001 ft)
roof nozzle or manhole for most applications. Accuracy: FlexLine XP: ± 0.4 mm (0.016”); FlexLine HP: ± 1 mm (0.04”); FlexLine
Still pipe antennae: For stilling well applications. Performs reliably, even AP: ± 3 mm (0.12”)
on rusty and contaminated stilling wells. No cone adapters needed. Measuring Method: FMCW Synthesized Pulse Reflectometer, X-band (9.538
Free space wide array linear planar (WALP) antennae: For applications where GHz) R&TTE FCC compliant
the antenna position is close to the tank shell.The hinged construction Ambient Temperature: -40°to 149° F (-40° to 65° C)
of the T06 enables mounting through a standard 6” nozzle. Safety Approvals: ATEX, CD, IECEx, OIML, CB Scheme, FM, CSA, FCC, API, NMi,
V 03.2010
254 GAUGING Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-923-1790
Pressure Transmitters
Accuracy ±0.016” (±0.4 mm) ±0.04” (±1 mm) ±0.12” (±3 mm)
Instruments
Signal Processing Advanced digital signal processing (ADSP) Advanced digital signal processing (ADSP) Digital signal processing (DSP)
Output Standard Modbus or GPU via RS-232C Standard Modbus via RS-232C or RS-485, RS-232C or RS-485 for indoor use or radio
or RS-485, 4-20 mA with HART protocol, 4-20 mA with HART protocol, (accuracy of modem connection, 4-20 mA with HART
(accuracy of analog level signal 0.1% full analog level signal 0.1% full scale) protocol, (accuracy of analog level signal
scale), Foundation Fieldbus 0.1% full scale)
Input VITO probes for average temperature, VITO probes for average temperature or —
HART devices (e.g., pressure transmitters) water bottom measurement, HART devices
Range 0-131 ft (0-40 m)
Resolution 0.004” (0.1 mm)
Measuring Principle FMCW synthesized pulse radar, 9.25 GHz to 10.75 GHx (X-band)
Flow Measurement
Approvals FM/CSA: Explosion proof Class I, Div 1, Groups B-D (per ANSI/NFPA 70); ATEX explosion proof also available.
Construction Chromatized, polyurethane-coated aluminum alloy housing, rated NEMA 4/IP67. FPM (Viton) wetted O-rings, Buna-N non-wetted
O-rings, three 3/4” NPT cable entries
Power Supply 110- 240 VAC 45/65 Hz or 24-64 VDC; Autoselect -20% to +10%
Power Rating Basic 10 VA, 25 VA max with options
Lightning Protection Full galvanic isolation
Communication Serial ASCII coded, BiPhase Mark modulated (BPM) standard Enraf fieldbus (GPU protocol)
Alarm Relay Output Two SPDT, galvanically isolated
Solids Flow and Motion
Compatible Antenna Types High temperature antennae: For free space applications at
Planar free space antennae: Can be mounted on a roof high temperatures and aggressive chemical elements.
nozzle or manhole for most applications. Measuring Range: 59 feet (18m)
Still pipe antennae: For stilling well applications. Performs Temperature Range: -40° to 446°F (-40° to 230°C)
reliably, even on rusty and contaminated stilling wells. Operating Pressure: To 87 PSI (6 Bar)
No cone adapters needed. Wetted Parts: AISI 316 stainless steel, reinforced TFM
Free space wide array linear planar (WALP) antennae: For High pressure cone antennae: For use in spheres and bullet
applications where the antenna position is close to the tanks at high pressures. The reference pin function al-
tank shell. The hinged construction of the T06 enables lows safe verification without opening the tank. A 1” or
mounting through a standard 6” nozzle. 4” full bore ball valve can also be included.
Actuator Motors and
Pneumatic Drives
Measuring Range: 131 feet (40m) Measuring Range: 131 feet (40m)
Temperature Range: -40° to 212° F (-40° to 100° C) Temperature Range: -330° to 482°F (-200° to 250°C)
Operating Pressure: To 87 PSI (6 Bar) Operating Pressure: To 580 PSI (40 Bar)
Wetted Parts: AISI 316 stainless steel and FEP Wetted Parts: AISI 316 stainless steel, PTFE, and CF8M
for optional ball valve
To order a Honeywell Enraf tank gauging system, fill out the application datasheet
from www.Lesman.com/datasheets and send it to Lesman for engineering review.