Decentralized Wastewater Treatment Systems

Iloilo Mission Hospital


Mission Road, Jaro, Iloilo City

: Wastewater Treatment Plant for System in Brief


Kind of Project
Hospitals
Wastewater Sources
: Consultancy Design Supervision,  IMH Centennial Building
Approaches
Warranty  New Building
Owned and Funded by : Iloilo Mission Hospital  Annex I, II
 Doctors and Nurses Boarding
Construction Start : August 2008 House
 Maintenance Room
Operation Start : May 2009  Emergency Room
 Laundry
Rationale
 Iloilo River is the most important body of water for the Treatment Modules
Ilonggos and it is identified as one of Water Quality  Anaerobic Baffled Reactor
 Anaerobic Filter
Management Area. Due to water pollution affecting
 Horizontal Planted Gravel Filter
the river, the local government has took their initiative
in solving the problem. Kinds of Wastes
 Iloilo Mission Hospital as one of the contributor of  Domestic
harmful wastes come up with a treatment facility that  Sewage Pathogens
can reduce pollution load from the establishment.
 DEWATS as their wastewater treatment plant, gather Key Figures
the generated wastewater from the hospital and treat
No. of beds 290
it to comply with the effluent standard set by the
government. No. of Staff 508

WWTP Capacity (cu.m/d) 291

BOD Influent (mg/l) 250


COD Influent (mg/l) 450

Sampling Laboratory
30
Result (BOD mg/l)
Total Area (sq. m) 1067
ABR 273.5
AF 68
PGF 725.5
Construction Costs [PhP] 3.2M

*influent is an assumption only


TECHNICAL DESCRIPTION
Treatment capacity : The DEWATS has the capacity to treat 291 cu.m. of wastewater
discharged daily.
Technical components :1 Module = 8 chambers Anaerobic Baffled Reactor (ABR), 1 chamber
Anaerobic Filter (AF). A treatment system with 3 modules was designed for
operation and maintenance purposes and a common Planted Gravel Filter
was constructed for all the module
Effluent Standard Quality : BOD5 ≤ 50 mg/l and TSS≤ 70 mg/l

MANAGEMENT
Monitoring : DEWATS performance will be monitored by BNS-Phils during the one year
warranty period and effluent quality will be analyzed on a regular basis
through DENR-accredited laboratories for six (6) consecutive months.
TECHNICAL LAY-OUT

B C
A

Legend
A-ABR
B-AF
C-PGF