Intrabreath: Testing during Exercise

Subjects, whose Flow-Volume Loop is considerably reduced, cannot exercise to a maximum. The Intrabreath
program allows to superimpose the Flow-Volume Loop at rest to the Flow-Volume Loop during exercise and
consequently provides information about a possible ventilatory limitation or emphysema during the measurement.
Besides, EELV and IC will be determined exactly.

MasterScreen™ CPX
Intrabreath measurement at 50 watts Intrabreath measurement at 120 watts

Unlimited networking possibilities


The JAEGER JLAB database provides multiple
networking possibilities. No matter whether you
intend to network simply MasterScreen CPX or
multiple JAEGER systems - you only have
one central database on a single server.
Consequently, patient data have to be en-
tered only once or are imported from the
practice administration system (PAS) via
the GDT interface or from the hospital
information system (HIS) via the HL7 inter-
face. Of course, data can also be ex- Small, lightweight and com-
changed vice versa. pact design
At your workstation computer you are free to Breath by Breath
choose whether you want to view the reports or the
Intrabreath including Flow-
printout only (Reader) or whether you want to edit the Volume Loop during exercise
data, for example, for AT determination. If you have a net-
work of many workstations, our Intranet-based I-Net Server will be Expandable for mobile use
at your disposal. You simply require a Browser and Acrobat Reader for
Integrated ECG
each of your workstations. You can also create a report in PDF format and
save it to any location in your network. Nutrition Assessment
Contact us for detailed information. Cardiac Output
Complies with international
Performance Features Europe:
regulations, MDD and FDA
CareFusion Germany 234 GmbH
 Full-featured exercise test including  Automatic ergometer control Leibnizstrasse 7
Flow-Volume-Loop  Powerful analysis software including Report 97204 Hoechberg
+49 931 4972-0 tel
 Breath-by-Breath measurement Generator
+49 931 4972-423 fax
 AT determination according to different methods  Interfaces for practice administration systems
MasterScreen CPX and options
 Functional, compact design Options: USA:
 Automatic volume and gas calibration  Integrated 12-lead ECG CareFusion Respiratory Care
 Ambient module for temperature and pressure  Interface for GE-ECG, Cardiosoft 22745 Savi Ranch Parkway
Yorba Linda, CA 92887
Cardiopulmonary Exercise Testing
 Interface for Custo-, AmedTec-, Medset-ECG
by JAEGER™
 Indirect Calorimetry +1 714 283 2228 tel
 Intrabreath measurement for dynamic on request +1 714 283 8493 fax
 Suction unit
Flow-Volume Loop
 Calculated Cardiac Output  Dual Monitor It’s experience that counts
 Pulse oximeter with finger clip and ear clip  Heart rate monitoring including Polar belt © 2009 CareFusion or one of its affiliates.
All rights reserved.
 Off-line blood gases/lactate and  Mobile system JAEGER and MasterScreen are trademarks or registered
trademarks of CareFusion Corporation or one of its affiliates.
AaDO2 estimation  Mobile system including telemetry PN 791805

 Training and nutrition reports  Bicycle ergometer/Treadmill ergometer


CareFusion Outpatient Monitoring Lung Function Diagnostics Cardiorespiratory Diagnostics
 Interpretation program IntelliSupport  Network carefusion.com Respiratory Care
Your partner: Sleep Diagnostics & Therapy Point-of-Care Diagnostics Ventilation
40 Years of Experience in Exercise Testing packed in a Compact Unit The TTest
est
Don’t leave anything to chance. Already during the test the program pro-
Evaluation
Correct evaluation is of major importance, as a large Interpretation program
vides you with an excellent breath-by-breath overview. Just click to jump to amount of data accumulates during cardiopulmonary
IntelliSupport
IntelliSupport, a graphics-based expert system,
MasterScreen CPX: Excellent in both stationary Option: different displays: exercise testing.
supports the busy physician in data analysis. Based
and mobile use Suction unit
Exercise testing and dy- Anaerobic Threshold on the accepted guidelines and predicted values
Option: Dual-Monitor, Small, lightweight and including 3- described by the worldwide renowned Professor
We have taken careful note of the clinician’s requirements to create ECG and exercise data on se- highly-precise analyzers namic Flow-Volume Loop The data can be evaluated directly after collection.
dimensional Karlman Wasserman, IntelliSupport uses decision
a small and partially mobile system which offers the full spectrum of parate TFT screens during exercise If desired, the test can also be evaluated later as
extension arm trees to guide the clinician through the data
cardiopulmonary measurements. MasterScreen CPX allows you to MasterScreen CPX allows you to read in an already accumulated during a test to arrive at a suitable
run a complete exercise test including stress ECG (option) quickly stored test. Evaluation is focussed on the determina- interpretation.
and easily. 3-dimensional
tion of the Anaerobic Threshold (AT). Different meth-
extension arm ods such as V-Slope, Breathing Equivalent, RQ=1
Volume Sensor: Precise and lightweight for precise and Lactate are available. The measurements will be
positioning of displayed at AT to perform a plausibility check.
Our patented digital TripleV-Volume Sensor complies with ATS crite-
analyzers
ria, performs without drift and is completely insensitive to moisture.
This is highly sophisticated technology you can really rely upon. As Breath-by-Breath and
compared to a turbine, the flat fan system has no starting or hunt- Intrabreath
ing problems due to its small inertia. Thanks to its compact and
lightweight design (45 g only), the sensor adds minimal resistance The nine-panel graph by
to airflow and has a dead space of only 30 ml. Patients and ath- Wasserman can already
letes will highly appreciate the fact that it is extremely comfortable be displayed during the
to wear with both mask and mouthpiece. test. Automatic self-adjust-
Trolley with modern
The TripleV-Volume Sensor can be used for all groups of patients ing axis scaling ensures
from children and adults to critically ill patients and athletes.
design and adjustable
optimal display.
desk; computer,
automatic calibration „Custom displays can be Intelli Support interpretation program
Highly-precise unit and isolation created individually “
digital TripleV Sensor IntelliSupport interprets, for example:
transformer included. • Anaerobic Threshold
Evaluation of Anaerobic Threshold • Maximum Oxygen Uptake
Nine-panel graph • Maximum Dynamic Flow-Volume Loop
• Arterial Blood gases, O2 pulse and ECG at
VO2max
If you want to view a spe- Nutrition Assessment: For a perfect diet Besides, the program calculates the perfect training
Option: VIAsprintTM 150/200P cific curve simply double-
Option: Swivel- click on the desired graph The Indirect Calorimetry program allows to determine ranges for:
State-of-the-art, rpm-independent • Weight loss, endurance training
mounted lateral desk and a full-screen graph the Basal Metabolic Rate and exercise-dependent En-
bicycle ergometer including seat and • Increase in performance
Operation: Easy and quickly to comprehend handle-bar adjustment
will be displayed. This is ergy Expenditure (EE) including a differentiation be-
sophisticated Windows tween carbohydrates, fats and proteins for perfect
Every system is just as good as its operator. Consequently, opera- training control and effective weight loss. Energy Ex-
Cardiac Output
technology!
tion must be easy to ensure that you can quickly master the system penditure is calculated on the basis of VCO2, VO2 and Cardiac evaluation is based on the dynamically
and not vice versa. Less consequential costs MasterScreen CPX: Expandable urea nitrogen. Special reports for training control and calculated Cardiac Output according to Wasserman.
Automated program sequences can be controlled by MasterScreen CPX is a paradigm of cost-effectiveness. for mobile use nutrition are included. For assessment of cardiac insufficiency special slopes
The system is featured by gas analyzers with a long eco- such as VE/VCO2 are calculated.
a single key thus allowing you to concentrate on your
patient rather than on computer monitors. Is there nomic lifetime and minimum gas consumption during
Full-screen display
anything easier? calibration (50 mL).
With the optional Online Service Agreement you can Combined graph:
Volume and gas analyzer calibration is done automatically and is make use of cost-saving and quick support without re- Mobile system Mobile system CPX and ECG
consequently just as easy as operation. A manual calibration pump quiring a service technician to travel to your site. including „ECG including automatic
is not required. telemetry
Training and competence ST measurement“
Automatic CPX
volume Exercise testing is a very complex issue; however, an in-
calibration ternationally recognized team of trainers will be at your
disposal to meet the great demand for training in this
area. Not only do we offer theoretical and practical
Automatic gas training courses but also courses in interpretation.
analyzer
Automatic calibration calibration
ECG and CPX Evaluation of Indirect Calorimetry Measurement Evaluation of Cardiac Output